Каталог дутьевых горелок. Март 2005
TRANSCRIPT
Index
1
Introduction 2
Important information 4
Key to burner symbols 5
Electronic Modulating Burners 6
LX Burners 7
LX burners with Inverter 8
Diagrams on electric consumption and noise level 9
How to choose the right gas train for the burner 10
Combustion air flow correction factor in accordance with the temperature 11
and altitude (above sea level)
Light oil nozzle flow rate table 12
Heavy oil nozzle flow rate table 13
Graphs and tables 14
Light oil burners 26
Heavy oil burners 48
Gas burners 60
Gas/light oil dual fuel burners 130
Gas/heavy oil dual fuel burners 154
Modulation kits 166
Return nozzles 167
Accessories for connection of burners to gas mains 168
Gas train structure and composition 170
Boiler connection flange 178
2
Developed
on the basis of a rolling
research programme conducted both
in-house and in liaison with top level
scientific and academic institutes, all
Baltur products are characterized by
their technological excellence. Drop
stop devices, anti-pollution systems,
and air/gas premixing are just a few of
the many solutions Baltur designed to
limit fuel consumption
and minimize environ-
mental impact. The five principal
lines and broad range of standard prod-
ucts are completed by personalized
solutions for individual applications.
BGN low NOx and CO burners, BTL burn-
ers, GI 1000 burners for industrial
boilers, are just some of the models
that reflect the flair and competence of
Baltur technology.
Website
Apart from providing instant access to infor-
mation about the company and our products,
the corporate website at www.baltur.com fea-
tures an authoritative on-line resource for all
HVAC professionals. Designers, heating engi-
neers, installers and dealers can consult infor-
mation on technical, commercial, legislative,
and administrative issues simply by clicking on
the relative topic headings. To access this
reserved area of the site, visitors are asked to
fill in a simple form before being assigned a
personal password that will allow them to nav-
igate around the various sections. In the first
six months of 2000 alone, this specialized
channel of communication was accessed by
more than 15,000 professionals.
3
Baltur Training Programme
Personnel training is one of the basic ingredi-
ents in the success of a company. That’s why
we set up a modern, fully-equipped in-house
Training Centre, enabling us to leverage the
competence and skills of our workforce, while
also assisting conscientious industry profes-
sionals who insist on keeping pace with today’s
fast-changing technology. With some 60 cours-
es and an average 650 participants each year,
the Training Centre keeps personnel up to date
and constitutes a point of reference for all
HVAC professionals.
Research laboratories
Apart from the guarantees implicit in ISO
9001 and ISO 14001 certifications, the
high quality of Baltur products is support-
ed by the input from our in-house
Research Centre, where teams of skilled
technical personnel run daily tests and
experiments on prototype burners and
thermal modules. The Centre’s staff also
perform stringent periodic checks on all our
products, thus offering a further guarantee
of the company’s hallmark reliability.
When choosing a burner you must bear in mind the following:
1- COUPLING FLANGE1.1 – All burners are equipped with a coupling sliding flange which allows
the exact positioning of the combustion head inside the combustionchamber in compliance with the boiler manufacturer’s rules.This does not apply to BTL 3, BTG 3 and COMIST 36.On request BTL 3 and BTG 3 can be supplied with a long head sli-ding on the coupling flange.
2 – BLOWN AIR BURNERS2.1 – Blown air burners capacity is closely linked to the back-pressure in the
combustion chamber. To ensure that you choose the right model it isnecessary to examine the flow-rate/pressure diagrams given in thebrochures and technical documentation.
2.2 – Blown air burners can be used on pressurised or suction pressure boi-lers without any special adaptation.
3 – MODULATING BURNERS3.1 – Modulating burners are obtained by ordering two-stage progressive
burners plus the complete automatic proportional modulation regula-tor, model POLI-GYR RWF40 and the relative modulation KIT (seepage 166).
4 - GAS AND DUAL FUEL BURNERS4.1 – Single-stage, two-stage and LX gas and combination burners must
be ordered complete with gas train and any adapter; these itemsare to be selected on the basis of gas pressure at the regulatorinfeed, the required quantity of gas and the backpressure in thecombustion chamber.ORDERS FOR BURNERS WITHOUT GAS TRAINS WILL NOT BEACCEPTED.
4.2 – All gas and combination burner trains are delivered pre-assem-bled and pre-wired.
4.3 – If mains pressures are different from those indicated please con-tact our Sales Office so we can make an estimate (with relativeprice increase/decrease) based on an exact calculation of the gastrain.
4.4 – The gas feed unit must comply with the standards in force.
5 - SERIES LX LIGHT OIL BURNERS5.1 - Series LX light oil burners are suitable for combustion chambers
with gas outlet from the chamber base (e.g. 3-pass boilers).They cannot be installed on reverse flame boilers.The burner has been assessed on test boilers in compliance withthe provisions of European standard EN267. For firebox dimensions that differ with respect to EN267 consultour technical service department.
6 – HEAVY OIL BURNERS6.1 – If you use heavy oil with a viscosity higher than 5° E at 50°C and up
to 15°E the system must be equipped with a feed circuit employing anauxiliary pump as per our technical drawings. The same can be saidwhen fuel viscosity is higher than 15°E at 50°C, yet in this event it isalso necessary to install burners from the DSNM-D, DSPN-D and GIDSPN-D series.These burners are WITHOUT a nozzle: to work out the complete priceof the burner (see page 167).
7 – “WITHOUT” BURNERS7.1 – Light oil and gas burners marked with a W (Without) provide the
same output and performance as standard models; although theyare without a cover, they nevertheless remain compact and stylish.
8 – 60Hz BURNERS8.1 – The operating range of the burners has been obtained in com-
pliance with EN 267 (Light oil burners) and EN 676 (Gas bur-
ners) with frequency 50Hz. For operation at 60Hz the operatingrange increases by about 15%.
9 – IMPORTANT NOTES9.1 – Diagrams are indicative only and refer to test boilers as per the
standards in force.In practice there may be differences, which stem from the fol-lowing factors:a) The capacity/incapacity of the burner to overcome the back-pressure on ignition (different from standard operating pressure),which varies from boiler to boiler.b) High thermal load in the combustion chamber (relationshipbetween combustion chamber output and relative volume -kW/m3) so the burner fan might not allow utilisation of the entireoperating range.
10 - NOTES10.1 –For technical datas and special products offers please refer to
the local Baltur dealer or contact directly Baltur Head Office attel. +39 0516843711, fax +39 0516830686, e-mail [email protected]
10.2 –For information not contained in this price list (terms of delivery –installation instructions – special regulations etc.) refer to the spe-cific materials (brochures – technical instructions etc.) and/or ourauthorised technical centres.
ALL DATA IS INDICATIVE ONLY; BALTUR RESERVES THE RIGHT TO MODIFYTECHNICAL DATA AND OTHER INFORMATION ON THE PRICE LISTWITHOUT GIVING PRIOR NOTICE.
Important information
4
LIGHT OILBTL... • SPARK... • BT...GSingle-stage (On-Off) light oil burners.
BTL...P • SPARK...DSG • BT...DSG • BT...DSG 3VTwo-stage light oil burners.
RiNOx...LSingle-stage light oil burners (ON-OFF) with low pollutant emissions.
RiNOx...L2 • SPARK 35 LX • BT...LXTwo-stage light oil burners with low pollutant emissions.
BT...DSPG • GI...DSPGProgressive/modulating two-stage light oil burners.Return nozzle with closure via electromagnet-controlled rods.
HEAVY OILBT...NSingle-stage (on-off) heavy oil burners.
BT...SPNHeavy oil burners.Pressure-drop operation (low-flame start up) – just one nozzle.
BT...DSN 4TTwo-stage heavy oil burners.
BT...DSNM-DTwo-stage extra heavy oil burners.Return nozzle with closure via electromagnet-controlled rods.
BT...DSPNProgressive/modulating two-stage heavy oil burners. Return nozzle with closure viaelectromagnet-controlled rods.
GI...DSPN-DProgressive/modulating two-stage extra heavy oil burners. Return nozzle withclosure via electromagnet-controlled rods.
GASBTG... • SPARKGAS... • BGN...Single-stage (on-off) gas burners.
BTG 20...Single-stage (on-off) gas burners with low pollutant emissions.
BTG...P • SPARKGAS... P • BGN...PTwo-stage gas burners.
BTG 20PTwo-stage gas burners with low pollutant emissions.
BTG 20 LX • SPARKGAS 30 LX • BGN...LX • GI 1000 LXTwo-stage progressive/modulating low pollutant gas burners with pneumaticregulation.
BGN...DSPGN • GI...DSPGNProgressive/modulating two-stage gas burners.
GI...MEModulating gas burners with electronic cam.
GI 1000 LX MELow emission modulating gas burner with electronic cam.
DUAL FUELMINICOMIST... • COMIST 20Single-stage (on-off) gas/light oil burners. Dual operating mode.
COMIST...SPPressure-drop (on-off) gas/light oil burners. Dual operating mode.
COMIST...Two-stage gas/light oil burners.Dual operating mode.
COMIST...DSPGM • GI MIST...DSPGMProgressive/modulating two-stage gas/light oil burners.Dual operation mode. Return nozzle with closure via electromagnet-controlled rods.
COMIST...NTwo-stage gas/heavy oil burners. Dual operating mode.
COMIST...NMTwo-stage gas/heavy oil burners. Dual operating mode. Return nozzle with closurevia electromagnet-controlled rods.
COMIST...DSPNM • GI MIST...DSPNMProgressive/modulating two-stage gas/heavy oil burners.Dual operating mode. Return nozzle with closure via electromagnet-controlled rods.
N.B. The letters indicate the model; burner power is indicated in the spaces.
...HINGEDBurner equipped with hinge
...DACABurner equipped with automatic air closure device
...HWith preheating.
...WWithout cover.
...VBurner equipped with frequency converter (INVERTER).
...MEBurner equipped with electronic cam modulation.
Key to burner symbols
5
66
Electronic Modulating Burners
Burner operating display with programmingkeypadUsed to display the operating sequence of theposition of the air servomotor and servomotorcommand.Burner operating time and number of success-ful start-ups.Also indicates the quality of the flame detect-ed. If the burner is blocked, an error code willbe displayed for immediate recognition of thecause of the block. You can display the fuelconsumption using a pulse signal coming fromthe gas flow measurer.Simple programming keypad for burner cali-bration.These functions are password-protected.
Electronic camElectronic programmer with microprocessorfor commanding and monitoring the burnerfunctions.Modulating functioning using a heat-regulator(on request).Built-in gas valve seal control.Set up for remote release.Electrical connection using coded click-in pinsto prevent cabling errors.Fitted with eBUS connection.
Servomotors for air and fuel adjustmentThe air and gas flows are adjusted using step-ping mode servomotors with precision to onetenth of a degree.The considerable precision of the adjustmentsmakes it possible to maintain the combustionat optimal values at all the load points.
Traditional modulation systems (mechanical modulation) used in standard burnershave a mechanical connection between the servomotors and the adjustment partswhich use rods, drive levers and joints.This creates mechanical play and hysteresis in the combustion air/fuel calibrationsystem, which creates imprecision for the combustion adjustment, especially at theminimum loads.This combustion adjustment imprecision translates as loss of efficiency in terms ofenergy yield.With electronic modulation, there is absolutely no mechanical play and hysteresisas the servomotors are connected directly to the adjustment devices, without drivelevers or rods.This guarantees optimal combustion values at all the load points.The correct position of the servomotors (stepping mode, with precision to one tenthof a degree) is guaranteed by the electronic cam, the new microprocessor “flamecontrol”, which is used to command and monitor all the burner functions.The electronic cam has a built-in gas seal control. The PID temperature/pressureload adjuster is an optional for the BGN series and standard for GI series indus-trial burners. The combustion air/fuel ratio adjustment curve (with configurableworking points) is programmed using a programming keypad with display.This curve is password-protected.The display can be used to display a whole series of information.For example, if the burner is blocked, an error code will be displayed for imme-diate recognition of the cause of the block and rapid solving of the problem.The Me series burners comply with the ever increasingly demanding requirementsof a market which requires combustion systems with high energy efficiency, con-siderable technological content and cost cuts for installation and maintenance.The creation of these ME series burners is confirmation that the technology used iscontinuously being developed, with increasing precision, reliability and durationover time. At the same time, costs are continuously being reduced, making use ofthese burners more convenient.
Legend:1 Electronic cam.2 Burner display.3 Stepping mode servomotor for combustion air adjustment.4 Stepping mode servomotor for fuel adjustment.5 Gas train.
5
4
3
1
2
77
LX Burners
Legend:1 Pneumatic gas valve.2 Gas pulse intake.3 Blower pressure intake.4 Combustion chamber pressure intake.5 Air adjustment flap.
12
3
4
5
Baltur has designed burners with blast heads which permit extremely low pollut-ing emissions of NOx and CO, in accordance with “Class III” of the EuropeanStandard EN676.
APPLICATIONSLX range burners offer very high performance with low emissions, a wide operat-ing range, high levels of applied technology and, above all, flexible use.In fact, in addition to producing very low harmful emissions, LX range burners arealso outstanding modulating burners and can therefore be used for any applica-tion requiring a multi-stage gas-fired burner. To obtain the low NOx emissions declared, the burner must be combined with suit-able boilers: three-pass, condensing and any direct exhaust generator with ther-mal load not higher than 1.8 MW/m3.
OPERATIONLX range burners are manufactured exclusively in two-stage progressive and mod-ulating versions.With two-stage progressive output use, the burner goes from min. to max. (andvice versa) without stopping in intermediate stages, controlled by a thermostat orpressure switch according to the type of system. In this way the burner goes smoothly from one power level to another. However, the burner is mainly used in the modulating version, which means it canbe used as a true multi-stage burner. With the use of the RWF 40 electronic control, already foreseeable as standard,or with an external PLC type control system, LX range burners no longer work onjust two single power “steps” but with countless flame stages, punctually adjustingto the system’s precise heat requirements.
FLAME MODULATIONIt was decided to combine a new type of pneumatic modulation using “GARC”(constant gas-air ratio) valves with the particular type of combustion head offer-ing emissions well below the most restrictive limits of current regulations.This new system is much more efficient and easier to use than the mechanical mod-ulation widely used in burners and whose best use requires great experience.Adjustment is limited to selecting the required air/gas ratio (that determines thepercentage of excess oxygen), and adjusting this ratio only to burner maximumand minimum capacity; the innumerable intermediate stages are self-regulating
thanks to the particular characteristics of these valves.The burner becomes much “leaner” in no longer requiring the servomotor system,the lever mechanisms or the shutter valves usually used with normal modulators,and the quantity of gas introduced in the combustion chamber depends only onthe amount of air that will increase and decreased thanks to a simple air shutter.The system is also defined as “dynamic”, i.e. self-regulating if the conditions (gasand air flowrates and pressures) change for any reason, and is thus safer whilerequiring less maintenance.
The combination of the new combustion head and the new modulation method gives riseto a range of burners that are truly cutting-edge in terms of combustion technology. The use of this burner will be A CONCRETE CONTRIBUTION TOWARDSIMPROVING THE ENVIRONMENT WE LIVE IN.
ADVANTAGES OF THE GARC SYSTEM:
VERY HIGH MODULATION RATIOSHigh modulation ratios ensure very small fluctuations in the controlled value (T° ofthe water or steam pressure), optimizing running economy, comfort, and burnerand heat generator life.Dynamic modulation control:ensures constant performance and absolutely safe operation even if foreignobjects block all or part of the air intake.O2 IN FUMES CONSTANTThe constant gas-air ratio assures constant residual oxygen levels in the fumes, alwaysoffering high boiler efficiencies for boilers, and above all condensing boilers.EASY USE AND MAINTENANCEThe GARC system makes intervention on the burner quick and easy, adjusting twoscrews and reducing adjustment times by 75% compared with a conventionalmechanically-adjusted modulating burner.
88
LX burners with Inverter
Energy costs and the pollution associated with its production require increasing attentionto consumption.It therefore becomes necessary to produce systems that are increasingly more efficient.Today, non-dissipating control systems that reduce losses to minimum, are preferred.In fact, the fan of a burner in conventional configuration always absorbs the same elec-trical power (with negligible variations) with the variations in burner operating power. The air flow is regulated exclusively by the air shutters which close as the power isreduced, limiting the air inlet section and therefore inducing a higher loss of load that infact dissipates a part of the electrical power supplied by the fan motor. Moreover, in such a configuration the fan always runs at top speed, thus generatingmaximum noise at every operating power.
These limits can be exceeded by installing a static frequency converter inside thecontrol panel, and which varies the fan rpm with the change in burner power.The frequency converter receives the signal that regulates the rpm directly from thecombustion air actuator, regulating the flowrate according to actual requirements,for better energy management.For SPARKGAS 30LX, BGN 40LX, BGN 60LX, BGN 120LX models the frequency con-verter is incorporated on the motor, with considerable advantages in terms of reduceddimensions, electrical wiring and assembly costs.
The air shutters remain on the burner and carry out an air flow and dynam-ic air pressure fine adjustment function at the combustion head, above allduring transients. Use of the frequency converter offers considerable savings in electrical powercosts for feeding the fan, with peaks of 70 % at min. burner power and aweighted annual reduction in the order of
EXAMPLE: a BGN 300 LX 3.6 MW gas burner will need to be fed by a fan with7.5 kW motor; an installation in a process system and therefore a burner opera-tion of 4800 hours a year at 50% max. power burnt (average load of burner inan industrial process), without inverter gives an approximate consumption of: 4.7 kW/h x 4800 h = 22,560 kW.Presuming an electrical energy cost of 0.15 Euro gives an annual energy cost of:22,560 kW x 0.15 Euro/Kw = 3,384.00 Euro
Using the Inverter gives a yearly consumption of:2.43 kW/h x 4,800 h = 11,664 kW and a yearly energy cost of:11,664 kW x 0.15 Euro/kW = 1,749.60 Euro
Yearly saving:3,384.00 Euro - 1,749.60 Euro = 1,634.40 EuroThe quick amortization of costs is evidentMoreover, the energy-saving resulting from use of the frequency converter alsocontributes to safeguarding the environment; a contribution in line with the Balturpolicy towards the world we live in.
The second big advantage offered by inverter for regulating fan speed (rpm) is thevery high reduction in the sound pressure level at partial burner loads, with peaksthat can reach
at min. burner power with respect to the standard solution with air flow controlexclusively entrusted to the shutters and fan at nominal motor rpm. Other advantages regarding the use of the frequency converter are:- Power factor close to 1 at any speed.Therefore possible power factor improve-
ments are not necessary.- Reduction in starting currents: the frequency converter enables gradual starting
of the motor. Y/∆ starts or soft starters become unnecessary.- LOWER MECHANICAL STRESS: the absence of sudden starts considerably
reduces stress to the system, with benefits in terms of maintenance on themechanical parts.
The excellent performance for cost obtained using the frequency converter is self-evident.
30-40%
30%
BGN 300LX electrical power absorbed with and without inverter
0.0
1.0
2.0
3.0
4.0
5.04.7
2.4
2000
6.0
7.0
8.0
9.0
300 500 700 900 1100 1300 1500 1700 1900 2100 2300 2500 2700 2900 3100 3300 3500 3700
Power burnt [kW]
Pow
er a
bsor
bed
[kW
]
50 Hz
with inverter
without inverter
BGN 300LX noise level with and without inverter
7172737475767778798081828384858687888990919293
300 500 700 900 1100 1300 1500 1700 1900 2100 2300 2500 2700 2900 3100 3300 3500 3700
Power burnt [kW]
Noi
se le
vel
[dBA
]
50 Hz
without inverter
with inverter
Measurements on test tubes carried out in our laboratory according to EN 676. Measurements on test tubes carried out in our laboratory according to EN 676 at a distance of 1 metrefrom the burner.
99
Diagrams on electric consumption and noise level
Measurements on test tubes carried out in our laboratory according to EN 676. Measurements on test tubes carried out in our laboratory according to EN 676 at a distance of 1 metrefrom the burner.
BGN 60LX electrical power absorbed with and without inverter
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
1.10
100 150 200 250 300 350 400 450 500 550 600 650 700 750 800
Power burnt [kW]
Pow
er a
bsor
bed
[kW
]
50 Hz
with inverter
without inverter
BGN 60LX noise level with and without inverter
6364656667
6869707172737475
7677787980
100 150 200 250 300 350 400 450 500 550 600 650 700 750 800
Power burnt [kW]
Noi
se le
vel
[dBA
]
50 Hz
without inverter
with inverter
BGN 200LX electrical power absorbed with and without inverter
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230
Power burnt [kW x10]
Pow
er a
bsor
bed
[kW
]
50 Hz
with inverter
without inverter
BGN 120LX noise level with and without inverter
646566676869707172737475767778798081828384
150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250
Power burnt [kW]
Noi
se le
vel
[dBA
]
50 Hz
without inverter
with inverter
Measurements on test tubes carried out in our laboratory according to EN 676. Measurements on test tubes carried out in our laboratory according to EN 676 at a distance of 1 metrefrom the burner.
BGN 200LX electrical power absorbed with and without inverter
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230
Power burnt [kW x10]
Pow
er a
bsor
bed
[kW
]
50 Hz
with inverter
without inverter
BGN 200LX noise level with and without inverter
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230
Power burnt [kW]
Noi
se le
vel
[dBA
]
50 Hz
without inverter
with inverter
Measurements on test tubes carried out in our laboratory according to EN 676. Measurements on test tubes carried out in our laboratory according to EN 676 at a distance of 1 metrefrom the burner.
1010
How to choose the right gas train for the burner
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 200P metanoCE
ediz.02/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
0 5 10 15 20 25
PORTATA kW x100
PR
ES
SIO
NE
m
bar
20B
20C
20D
20E
20F
20A
colore molla regolatore
verde
neutra
rossa
Qi=1700
Pg=42
Using the specific diagrams, it is possible to select the gas train that is mostsuitable for the burner.First of all it is necessary to identify:- Burner’s heat input Qi [kW], to be identified along the x-coordinate.- Gas pressure available at the regulator Pg [mbar], to be identified along they-coordinate.The available gas pressure is determined by the formula: Pg=Pa-Pcwhere:- Pa = gas pressure provided by the mains supply;- Pc = the pressure in the boiler combustion chamber.The intersection point of the two lines defines the operational parameters of thegas train.The gas train characterised by the first curve underneath the intersection pointmust be chosen.
EXAMPLE- Burner = BGN 200P- Qi = 1700 kW- Pa = 44.5 mbar- Pc = 2.5 mbar- Pg = 44.5 – 2.5 = 42 mbarChoose the indicated curve 20C.
The red segment of the curve indicates that the neutral-coloured spring of theregulator must be replaced with the red one (supplied).
To identify the codes for the gas train, pressure regulator and adapter to beordered refer to the BURNER/TRAIN MATCH-UP TABLE relative to burnerBGN200P and CURVE REFERENCE 20C.
Note:In the graphs the head loss curves have different colours.The mono-colour BLUE curve represents a gas train with a monoblock valve.The mono-colour ORANGE curve represents a gas train with a mono-valve orwith separate valves without pressure regulator; this execution does not complywith EN676 regulation.The multi-colour curve represents a gas train with separate valves and pressureregulator (this version complies with EN676 regulation). The coloured segmentsidentify the colour of the spring with which the regulator should be used underthose specific flow rate/pressure conditions. The pressure regulator is suppliedwith different-coloured springs (green, red and violet): these are used to replacethe one already installed (neutral colour) at the time of installation if necessary.
Head loss (combustion head + gastrain + pressure regulator)
PRES
SURE
THERMAL OUTPUT
natural gas
Regulatorspring colour
greenneutralred
1111
Combustion air flow correction factor in accordance with the temperature and altitude(above sea level)
Air temperatur Altitude (metres above sea level)
°C 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000
f
0 1,071 1,040 1,009 0,978 0,950 0,920 0,895 0,867 0,841 0,813 0,791 0,765 0,7415 1,052 1,021 0,991 0,960 0,933 0,904 0,879 0,851 0,826 0,798 0,776 0,751 0,72810 1,033 1,003 0,973 0,943 0,916 0,888 0,863 0,836 0,,812 0,784 0,763 0,738 0,71515 1,015 0,986 0,956 0,927 0,900 0,872 0,848 0,822 0,797 0,771 0,749 0,725 0,70320 0,998 0,969 0,940 0,911 0,885 0,857 0,834 0,807 0,784 0,758 0,737 0,713 0,69125 0,981 0,953 0,924 0,896 0,870 0,843 0,820 0,794 0,771 0,745 0,724 0,701 0,67930 0,965 0,937 0,909 0,881 0,856 0,829 0,806 0,781 0,758 0,733 0,712 0,689 0,66840 0,934 0,907 0,880 0,853 0,828 0,803 0,781 0,756 0,734 0,709 0,690 0,667 0,64750 0,905 0,879 0,853 0,827 0,803 0,778 0,756 0,733 0,711 0,687 0,668 0,647 0,62760 0,878 0,853 0,827 0,802 0,779 0,754 0,734 0,711 0,690 0,667 0,648 0,627 0,60880 0,828 0,804 0,780 0,756 0,735 0,712 0,692 0,670 0,651 0,629 0,611 0,592 0,573100 0,784 0,761 0,739 0,716 0,695 0,674 0,655 0,634 0,616 0,595 0,579 0,560 0,543150 0,691 0,671 0,651 0,631 0,613 0,594 0,578 0,559 0,543 0,525 0,510 0,494 0,478200 0,618 0,600 0,582 0,565 0,548 0,531 0,517 0,500 0,486 0,469 0,456 0,442 0,428250 0,559 0,543 0,527 0,511 0,496 0,480 0,467 0,452 0,439 0,425 0,413 0,400 0,387300 0,510 0,496 0,481 0,466 0,453 0,439 0,426 0,413 0,401 0,387 0,377 0,365 0,353
The burner operating ranges indicated in the various documentation refer to atemperature of 15°C and an altitude of 0 m above sea level.It may occur that the burner has to operate with air at different temperaturesand/or altitudes. Therefore, its operating features must be modified.Heating of the air and/or increasing of the altitude reduce the density of the air,with a resulting reduction in the oxygen content. Therefore, burning the samequantity of fuel requires the same quantity of oxygen contained in a greatervolume of air.Given that the burner fan is not set up to increase the volume of air, it isnecessary to reduce the quantity of the fuel to be burned, with a resultingreduction in the maximum thermal output.This reduction leads to a reduction in the burner operating range obtained bymultiplying the maximum thermal output of the burner by a coefficient (seeTable) which accounts for the temperature of the combustion air and the altitude.It is necessary, therefore, to check if the working point is still within the newoperating range. If it is, the burner is still suitable for that application. If it is not,you must select a bigger burner.
EXAMPLECombining a light oil burner for a boiler with a combustion chamber power of1400 kW, pressure of 3.5 mbar, ambient temperature of 50°C and altitude of1000 m above sea level.Using the normal operating ranges and under normal conditions, the correctchoice is BT 120DSG 3V. It is necessary, however, to reduce the operatingrange as the ambient conditions have changed.
Using the formulaQr = Qmax x fWhere:Qr = reduced burner outputQmax = max. thermal output of the burner BT 120DSG 3V = 1660 kWf = correction factor calculated using the Table, by combining the 1000 mcolumn with the 50°C row = 0.803Qr = 1660 kW x 0.803 = 1333 kW
Under these ambient conditions, BT 120DSG 3V has a maximum output of 1333kW, which is insufficient for this boiler, which requires an output of 1400 kW.Therefore, BT 180DSG 3V is the ideal burner for this application.
mbar
2.5
15
12.5
10
7.5
5
0 kW22502000
1751501251007550kg/h
250
1750150012501000750500250
BT40DSG
1400 kW1333 kW
BT55DSG BT75DSG 3V BT180DSG 3VBT120DSG 3VBT100DSG
Gasolio
3,5 mbar
EXAMPLE
EXAM
PLE
Light oil
12
Light oil nozzle flow rate table
FLOW RATE AT NOZZLE OUTLET IN Kg/h
PUMP PRESSURE barNozzle Nozzle
G.P.H. 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 G.P.H.
0,40 1,18 1,27 1,36 1,44 1,52 1,59 1,67 1,73 1,80 1,86 1,92 1,98 2,04 2,10 2,15 2,20 2,25 2,31 2,36 2,40 2,45 0,40
0,50 1,47 1,59 1,70 1,80 1,90 1,99 2,08 2,17 2,25 2,33 2,40 2,48 2,55 2,62 2,69 2,75 2,82 2,88 2,94 3,00 3,05 0,50
0,60 1,77 1,91 2,04 2,16 2,28 2,39 2,50 2,60 2,70 2,79 2,88 2,97 3,06 3,14 3,22 3,30 3,38 3,46 3,53 3,61 3,68 0,60
0,65 1,91 2,07 2,21 2,34 2,47 2,59 2,71 2,82 2,92 3,03 3,12 3,22 3,31 3,41 3,49 3,58 3,66 3,75 3,83 3,91 3,98 0,65
0,75 2,20 2,38 2,55 2,70 2,85 2,99 3,12 3,25 3,37 3,49 3,61 3,72 3,82 3,93 4,03 4,13 4,23 4,32 4,42 4,51 4,60 0,75
0,85 2,50 2,70 2,89 3,06 3,23 3,39 3,54 3,68 3,82 3,96 4,09 4,21 4,33 4,45 4,57 4,68 4,79 4,90 5,00 5,11 5,21 0,85
1,00 2,94 3,18 3,40 3,61 3,80 3,99 4,16 4,33 4,50 4,65 4,81 4,96 5,10 5,24 5,37 5,51 5,64 5,76 5,89 6,01 6,13 1,00
1,10 3,24 3,50 3,74 3,97 4,18 4,38 4,58 4,77 4,95 5,12 5,29 5,45 5,61 5,76 5,91 6,06 6,20 6,34 6,48 6,61 6,74 1,10
1,20 3,53 3,82 4,08 4,33 4,56 4,78 5,00 5,20 5,40 5,59 5,77 5,95 6,12 6,29 6,45 6,61 6,76 6,92 7,07 7,21 7,35 1,20
1,25 3,68 3,97 4,25 4,50 4,75 5,00 5,20 5,40 5,60 5,80 6,00 6,20 6,35 6,55 6,70 6,85 7,05 7,20 7,35 7,50 7,65 1,25
1,35 3,97 4,29 4,59 4,87 5,13 5,38 5,62 5,85 6,07 6,28 6,49 6,69 6,88 7,07 7,26 7,44 7,61 7,78 7,95 8,11 8,27 1,35
1,50 4,42 4,77 5,10 5,41 5,70 5,90 6,24 6,50 6,75 6,98 7,21 7,43 7,65 7,86 8,06 8,26 8,46 8,65 8,83 9,01 9,19 1,50
1,65 4,86 5,25 5,61 5,95 6,27 6,58 6,87 7,15 7,42 7,68 7,93 8,18 8,41 8,64 8,87 9,09 9,30 9,51 9,71 9,92 10,11 1,65
1,75 5,15 5,56 5,95 6,31 6,65 6,98 7,29 7,58 7,87 8,15 8,41 8,67 8,92 9,17 9,41 9,64 9,86 10,09 10,30 10,52 10,72 1,75
2,00 5,89 6,30 6,80 7,21 7,60 7,97 8,33 8,67 8,99 9,31 9,61 9,91 10,20 10,48 10,75 11,01 11,27 11,53 11,78 12,02 12,26 2,00
2,25 6,62 7,15 7,65 8,15 8,55 8,97 9,37 9,75 10,12 10,47 10,85 11,15 11,47 11,79 12,09 12,39 12,68 12,97 13,25 13,52 13,79 2,25
2,50 7,36 7,95 8,50 9,01 9,50 9,97 10,41 10,83 11,24 11,64 12,02 12,39 12,75 13,10 13,44 13,77 10,09 14,41 14,72 15,02 15,32 2,50
3,00 8,83 9,54 10,20 10,82 11,40 11,96 12,49 13,00 13,49 13,96 14,42 14,87 15,30 15,72 16,12 16,52 16,91 17,29 17,66 18,03 18,35 3,00
3,50 10,30 11,13 11,90 12,62 13,30 13,95 14,57 15,17 15,74 16,29 16,83 17,34 17,85 18,34 18,81 19,28 19,73 20,17 20,61 21,03 21,45 3,50
4,00 11,77 12,72 13,60 14,42 15,20 15,94 16,65 17,33 17,99 18,62 19,23 19,82 20,40 20,95 21,50 22,03 22,55 23,06 23,55 24,04 24,51 4,00
4,50 13,25 14,31 15,30 16,22 17,10 17,94 18,73 19,5 20,24 20,95 21,63 22,30 22,95 23,57 24,19 24,78 25,37 25,94 26,49 27,04 27,58 4,50
5,00 14,72 15,90 17,00 18,03 19,00 19,93 20,82 21,67 22,48 23,27 24,04 24,78 25,49 26,19 26,87 27,54 28,19 28,82 29,44 30,05 30,64 5,00
5,50 16,19 17,49 18,70 19,83 20,90 21,92 22,90 23,83 24,73 25,60 26,44 27,25 28,04 28,81 29,56 30,29 31,00 31,70 32,38 33,05 33,70 5,50
6,00 17,66 19,00 20,40 21,63 22,80 23,92 24,98 26,00 26,98 27,93 28,84 29,73 30,59 31,43 32,25 33,04 33,82 34,58 35,33 36,05 36,77 6,00
6,50 9,13 20,67 22,10 23,44 23,70 25,91 27,06 28,17 29,23 30,26 31,25 32,21 33,14 34,05 34,94 35,80 36,64 37,46 38,27 39,06 39,83 6,50
7,00 20,60 22,26 23,79 25,24 26,60 27,90 29,14 30,33 31,48 32,58 33,65 34,69 35,69 36,67 37,62 38,55 39,46 40,35 41,21 42,06 42,90 7,00
7,50 22,07 23,85 25,49 27,04 28,50 29,90 31,22 32,50 33,73 34,91 36,05 37,16 38,24 39,29 40,31 41,31 42,28 43,23 44,16 45,07 45,96 7,50
8,30 24,43 26,39 28,21 29,93 31,54 33,08 34,55 35,97 37,32 38,63 39,90 41,13 42,32 43,48 44,61 45,71 46,79 47,84 48,87 49,88 50,86 8,30
9,50 27,96 30,21 32,29 34,25 36,10 37,87 39,55 41,17 42,72 44,22 45,67 47,07 48,44 49,77 51,06 52,32 53,55 54,76 55,93 57,09 58,22 9,50
10,50 30,90 33,39 35,69 37,86 40,06 41,73 43,74 45,41 47,20 48,90 50,50 52,00 53,50 55,00 56,40 57,80 59,20 60,50 61,80 63,10 64,30 10,50
12,00 35,32 38,20 40,80 43,30 45,60 47,80 50,00 52,00 54,00 55,90 57,70 59,50 61,20 62,90 64,50 66,10 67,60 69,20 70,70 72,10 73,60 12,00
13,80 40,62 43,90 46,90 49,80 52,40 55,00 57,50 59,80 62,10 64,20 66,30 68,40 70,40 72,30 74,30 76,00 77,80 79,50 81,30 82,90 84,60 13,80
15,30 45,03 48,60 52,00 55,20 58,10 61,00 63,70 66,30 68,80 71,10 73,60 75,80 78,00 80,20 82,20 84,30 86,20 88,20 90,10 91,90 93,80 15,30
17,50 5,51 55,60 59,50 63,10 66,50 69,80 72,90 75,80 78,70 81,50 84,10 86,70 89,20 91,70 94,10 96,40 98,60 100,90 103,00 105,20 107,20 17,50
19,50 57,40 62,00 66,30 70,30 74,10 77,70 81,20 84,50 87,70 90,80 93,70 96,60 99,40 102,20 104,80 107,40 109,90 112,40 114,80 117,20 119,50 19,50
21,50 63,20 68,40 73,10 77,50 81,70 85,70 89,50 93,20 96,70 100,10 103,40 106,50 109,60 112,60 115,60 118,40 121,20 123,90 126,60 129,20 131,80 21,50
24,00 70,64 76,30 81,60 86,50 91,20 95,70 99,90 104,00 107,90 111,70 115,40 118,90 122,40 125,70 129,00 132,20 135,30 138,30 141,30 144,20 147,10 24,00
28,00 82,41 89,00 95,20 101,00 106,40 111,60 116,60 121,30 125,90 130,30 134,60 138,70 142,80 146,70 150,50 154,20 157,80 161,40 164,90 168,30 171,60 28,00
30,00 88,30 95,40 102,00 108,20 114,00 119,60 124,90 130,00 134,90 139,60 144,20 148,70 153,00 157,20 161,20 165,20 169,10 172,90 176,60 180,30 183,80 30,00
G.P.H. G.P.H.
To choose the nozzle you need toknow the pump working pressure(in bar) and the required fuel flowrate (in kg/h).
Find the required fuel flow rate inthe relevant pump pressure column(choose the closest value, roundingdown as necessary).
Find the corresponding nozzle inG.P.H. in the blue box at the end ofthe horizontal row containing theflow rate value.
EXAMPLE Pump pressure: 12 barRequired flow rate: 15 kg/hFlow rate shown in table: 14.57Calculated nozzle: 3.50 G.P.H.
EXAMPLE
13
FLOW RATE AT NOZZLE OUTLET IN Kg/h
Heavy oil nozzle flow rate table
PUMP PRESSURE barNozzle Nozzle
G.P.H. 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 G.P.H.
0,60 2,50 2,60 2,70 2,80 3,00 3,10 3,20 3,30 3,35 3,40 3,50 3,60 3,70 3,80 3,90 3,95 4,00 4,10 4,20 4,30 4,40 0,60
0,65 2,70 2,80 3,00 3,10 3,20 3,30 3,40 3,50 3,60 3,70 3,80 3,90 4,00 4,10 4,20 4,30 4,350 4,40 4,50 4,60 4,70 0,65
0,75 3,10 3,30 3,40 3,60 3,70 3,80 4,00 4,10 4,20 4,30 4,40 4,50 4,60 4,70 4,80 4,90 5,00 5,10 5,20 5,30 5,40 0,75
0,85 3,50 3,70 3,90 4,00 4,20 4,30 4,50 4,60 4,70 4,90 5,00 5,10 5,20 5,40 5,50 5,60 5,70 5,80 5,90 6,00 6,10 0,85
1,00 4,20 4,40 4,60 4,70 4,90 5,10 5,30 5,40 5,60 5,70 5,90 6,00 6,20 6,30 6,40 6,60 6,70 6,80 7,00 7,10 7,20 1,00
1,10 4,60 4,80 5,00 5,20 5,40 5,60 5,80 6,00 6,10 6,30 6,50 6,60 6,80 6,90 7,10 7,20 7,40 7,50 7,70 7,80 7,90 1,10
1,20 5,00 5,20 5,50 5,70 5,90 6,10 6,30 6,50 6,70 6,90 7,10 7,20 7,40 7,60 7,70 7,90 8,10 8,20 8,40 8,50 8,70 1,20
1,25 5,20 5,40 5,70 5,90 6,10 6,30 6,50 6,60 6,80 7,00 7,20 7,30 7,50 7,70 7,80 8,00 8,20 8,40 8,50 8,70 8,90 1,25
1,35 5,60 5,90 6,20 6,40 6,60 6,90 7,10 7,30 7,50 7,70 7,90 8,10 8,30 8,50 8,70 8,90 9,10 9,20 9,40 9,60 9,70 1,35
1,50 6,20 6,50 6,80 7,10 7,40 7,60 7,90 8,10 8,40 8,60 8,80 9,00 9,30 9,50 9,70 9,90 10,10 10,30 10,40 10,60 10,80 1,50
1,65 6,90 7,20 7,50 7,80 8,10 8,40 8,70 9,00 9,20 9,50 9,70 10,00 10,20 10,40 10,60 10,90 11,10 11,30 11,50 11,70 11,90 1,65
1,75 7,30 7,60 8,00 8,30 8,60 8,90 9,20 9,50 9,80 10,00 10,30 10,60 10,80 11,00 11,30 11,50 11,70 12,00 12,20 12,40 12,60 1,75
2,00 8,30 8,70 9,10 9,50 9,90 10,20 10,50 10,90 11,20 11,50 11,80 12,10 12,30 12,60 12,90 13,20 13,40 13,70 13,90 14,2 14,40 2,00
2,25 9,40 9,80 10,30 10,70 11,10 11,50 11,80 12,20 12,60 12,90 13,20 13,60 13,90 14,20 14,50 14,80 15,10 15,40 15,70 15,90 16,20 2,25
2,50 10,40 10,90 11,40 11,90 12,30 12,70 13,20 13,60 14,00 14,30 14,70 15,10 15,40 15,80 16,10 16,50 16,80 17,10 17,40 17,70 18,00 2,50
3,00 12,50 13,10 13,70 14,20 14,80 15,30 15,80 16,30 16,80 17,20 17,70 18,10 18,50 18,90 19,30 19,70 20,10 20,50 20,90 21,30 21,60 3,00
3,50 14,60 15,30 16,00 16,60 17,20 17,80 18,40 19,00 19,60 20,10 20,60 21,10 21,60 22,10 22,50 23,00 23,50 23,90 24,40 24,80 25,80 3,50
4,00 16,60 17,50 18,20 19,00 19,40 20,40 21,10 21,70 22,30 23,00 23,50 24,100 24,70 25,30 25,80 26,30 26,80 27,40 27,90 28,40 28,80 4,00
4,50 18,70 19,60 20,50 21,40 22,20 22,90 23,70 24,40 25,10 25,80 26,50 27,10 27,80 28,40 29,00 29,60 30,20 30,80 31,30 31,90 32,40 4,50
5,00 20,80 21,80 22,80 23,70 24,60 25,50 26,30 27,10 27,90 28,70 29,40 30,20 30,90 31,60 32,20 32,90 33,60 34,20 34,80 35,40 36,00 5,00
5,50 22,90 24,00 25,10 26,10 27,10 28,00 29,00 29,80 30,70 31,60 32,40 33,20 34,00 34,70 35,50 36,20 36,90 37,60 38,30 39,00 39,70 5,50
6,00 25,00 26,20 27,40 28,50 29,60 30,60 31,60 32,60 33,50 34,40 35,30 36,20 37,00 37,90 38,70 39,50 40,30 41,00 41,80 42,50 43,30 6,00
6,50 27,10 28,40 29,60 30,80 32,00 33,10 34,20 35,30 36,30 37,30 38,30 39,20 40,10 41,00 41,90 42,80 43,60 44,50 45,30 46,10 46,90 6,50
7,00 29,10 30,60 31,90 33,20 34,50 35,70 36,90 38,00 39,10 40,20 41,20 42,20 43,20 44,20 45,10 46,10 47,00 47,90 48,80 49,60 50,50 7,00
7,50 31,20 32,70 34,20 35,60 36,90 38,20 39,50 40,70 41,90 43,00 44,10 45,20 46,30 47,30 48,40 49,40 50,30 51,3 52,20 53,20 54,10 7,50
8,30 34,50 36,20 37,80 39,40 40,90 42,30 43,70 45,00 46,40 47,60 48,90 50,10 51,20 52,40 53,50 54,60 55,70 56,80 57,80 58,80 59,80 8,30
9,50 39,50 41,50 43,30 45,10 46,80 48,40 50,00 51,60 53,10 54,50 55,90 57,30 58,70 60,00 61,30 62,50 63,80 65,00 66,20 67,30 68,50 9,50
10,50 43,70 45,80 47,90 49,80 51,70 53,50 55,30 57,00 58,60 60,20 61,80 63,30 64,80 66,30 67,70 69,10 70,50 71,80 73,10 74,40 75,70 10,50
12,00 49,90 52,40 54,70 57,00 59,10 61,20 63,20 65,10 67,00 68,90 70,60 72,40 74,10 75,80 77,40 79,00 80,50 82,10 83,60 85,10 86,50 12,00
13,80 57,40 60,20 62,90 65,50 68,00 70,40 72,70 74,90 77,10 79,20 81,20 83,20 85,20 87,10 89,00 90,80 92,60 94,40 96,10 97,80 99,50 13,80
15,30 63,70 66,80 69,80 72,60 75,40 78,00 80,60 83,00 85,40 87,80 90,10 92,30 94,50 96,60 98,70 100,70 102,70 104,60 106,60 108,50 1103,00 15,30
17,50 72,80 76,40 79,80 83,10 86,20 89,20 92,10 95,00 97,70 100,40 103,00 105,60 108,00 110,50 112,80 115,20 117,50 119,70 121,90 124,00 126,20 17,50
19,50 81,20 85,10 88,90 92,50 96,00 99,40 102,70 105,80 108,90 111,90 114,80 117,60 120,40 123,10 125,70 128,30 130,90 133,40 135,20 138,20 140,60 19,50
21,50 89,50 93,90 98,00 102,00 105,90 109,60 113,20 116,70 120,10 123,40 126,60 129,70 132,70 135,70 138,60 141,50 144,30 147,10 149,80 152,40 155,00 21,50
24,00 99,90 104,80 109,40 113,90 118,20 122,40 126,40 130,30 134,00 137,70 141,30 144,80 148,20 151,50 154,80 158,00 161,10 164,20 167,20 170,10 173,00 24,00
28,00 116,50 122,70 127,70 132,90 137,90 139,70 147,40 152,00 156,40 160,70 164,80 168,90 172,90 176,80 180,60 184,30 187,90 191,50 195,00 198,50 201,90 28,00
30,00 124,90 131,00 136,80 142,40 147,80 152,90 158,00 162,80 167,50 172,10 176,60 181,00 185,20 189,40 193,50 197,40 201,40 205,20 209,00 212,70 216,30 30,00
G.P.H. G.P.H.
Fuel atomising type Fuel atomising cone type DELAVAN Monarch Danfoss Steinen
Empty A PL H H-PH
Full B AR S S/SS
Universal W NS B QPLP
Half-empty E – – –
Cone full average AR-D AR – –concentration
Cone full R-D R – –concentration
1414
Diameter of the flame depending on of the quantityof heavy oil/light oil burnt (indicative values)
Diameter of the flame depending on of the quantity of heavy oil/light oil burnt (indicative values)
Diameter of the flame depending on of the quantity ofgaseous fuel burnt (indicative values)
Diameter of the flame depending on of the quantity ofgaseous fuel burnt (indicative values)
BT
8337
BT
8339
BT
50
3A
BT
1734
Graphs and tables
Flame diameter
Heavy oil to 50°E
Light oil
Heavy oil to 50°E
Light oil
1515
Length of the flame depending on the quantity ofheavy oil/light oil burnt (indicative values)
Length of the flame depending on the quantity ofheavy oil/light oil burnt (indicative values)
Length of the flame depending on the quantity ofgaseous fuel burnt (indicative values)
Length of the flame depending on the quantity ofgaseous fuel burnt (indicative values)
BT
8336
BT
8338
BT
1732
L
BT
504A
L
Graphs and tables
Flame Length
Heavy oil to 50°E
Light oil
Heavy oil to 50°E
Light oil
1616
Graphs and tables
Size of the gas feed pipes EXAMPLEWith a natural gas flow rate of 30 m3/h and a 6 m long feed pipe with adiameter of 1”1/2, there will be a gas pressure loss of 1mbar.
GAS
FLO
W R
ATE
m3 /
h –
natu
ral g
as: d
ensit
y re
lativ
e to
air
0.6
PRES
SURE
LOSS
: mba
r
PIPE
DIA
MET
ER: i
nche
s
PIPE L
ENGTH
: metr
es
Example
1717
Graphs and tables
When values are converted, note that the value obtained is never exactlyidentical to the original value. Round off the result of the calculation to anumber of decimal places no higher than that of the original value.Note - The following Tables are used to convert International Standard (IS) units.
The conversion values have been rounded off to three or four significantdecimal places, which may permit conversions which are sufficiently accurate forthe majority of applications.
multiply by to obtainacro 0,405 habar *100 kPabarrel (42 US gallon, petroleum) 159 l
0.159 m3
Btu IT 1.055 kJBtu/ft3 37.3 kJ/m3: J/lBtu/gal 0,279 kJ/lBtu•ft/h•ft2•°F 1.731 W/(m•K)Btu•in(h•ft2•°F) (thermal conductivity, K) 0.144 W/(m•K)Btu/h 0.252 kcal/hBtu/h 0.293 WBtu/ft2 11.4 kJ/m2
Btu/(y•ft2) 0.000293 kWh/(y•m2)(non SI)
Btu (y ft2) 0.0000114 GJ/(y•m2)Btu/(h•ft2) 3.15 W/m2
Btu/(h•ft2•°F) (overall heat transmission coefficient, U) 5.68 W/(m2•K)(thermal conductance, C) W/(m2•°C)Btu/(ib•°F) (specific heat, c) 4.19 kJ/(kg•K)bushel 0.0352 m3
calorie, gram 4.19 Jcalorie, kilogram, kilocalorie 4.19 kJcentipoise, viscosity, µ (absolute, dynamic) *1.00 mPa•scentistoke, kinematic viscosity υ *1.00 mm2/sdina/cm2 *0.100 PaEDR hot water (150 Btu/h) 44 WEDR vapour (240 Btu/h) 70.3 WEER 0.293 COPft *0.3048 mft *304.8 mmft/min, fpm 0.00508 m/sft/s; fps *0.3048 m/sft water column 2.99 kPaft water column for every 100 ft of pipe 0.0981 kPa/mft2 0.0929 m2
ft2•h•°F/Btu (thermal resistance, R) 0.176 m2•K/Wft2/s, kinematic viscosity, υ 92900 mm/sft3 28.3 lft3 0.0283 m3
ft3/h, cfh 7.87 ml/sft3/min, cfm 0.472 l/sft3/s, cfs 28.3 l/sft•Ibf (pair or moment) 1.36 N•mft-Ibf/I (energy specified) 2.99 J/kgft-Ibf/min (power) 0.0226 WUS gallon (231 m3) 3.79 lgallon 0.00379 m3
gph 1.05 ml/sgpm 0.0631 l/sgpm/ton ref. 0.0179 ml/Jgrain (1/7000 Ib) 0.0648 ggr/gal 17.1 mg/lgr/Ib 0.143 g/kgHP (boilers) 9.81 kWHP (550 ft-Ibf/s) 0.746 kWinch *25.4 mminch of mercury (60°F) 3.38 kPainch of water (60°C) 249 Pain/100 ft, thermal expansion 0.833 mm/min•Ibf (pair or moment) 113 mN•m
multiply by to obtainin2 645 mm2
in3 (volume) 16.4 mlin3/min (SCIM) 0.273 ml/sin3 (section modulus) 16400 mm3
in3 (section moment) 416000 mm3
km/h 0.278 m/skWh *3.60 MJkWh/(y•ft2) 0.0388 GJ/(y•m2)kWh/1000cfm 2.12 J/lkilopond (kg force) 9.81 Nkip (1000 Ibf) 4.45 kNkip/in2 (ksi) 6.89 MPalitre *0.001 m3
Ib (mass) 0.454 kgIb (mass) 454 gIbf (force or tension) 4.45 NIb/ft (uniform load) 1.49 kg/mIbm (ft•h) viscosity (absolute, dynamic µ) 0.413 mPa•sIbf (ft•s) viscosity (absolute, dynamic µ) 1490 mPa•sIb/h 0.126 g/sIb/min 0.00756 kg/sIb of vapour an hour at 212°F (100°C) 0.284 kWIbf/ft2 47.9 PaIbf s/ft2 viscosity (absolute, dynamic µ) 47900 mPa•sIb/ft2 4.88 kg/m2
Ib/ft3 (density, ρ) 16.0 kg/m3
Ib/gallon 120 kg/m3
micron of mercury (60°F) 133 mPamile 1.61 kmmph 1.61 km/hmillibar *0.100 kPamm of mercury (60°F) 0.133 kPamm of water (60°F) 9.80 Pam of water 9.80 kPanautical mile 1.85 kmounce (mass, avoirdupois) 28.3 gounce (force or tension) 0.278 Nounce (liquid, USA) 29.6 mlounce inch (pair, moment) 7.06 nN•mounce (avoirdupois) per gallon 7.49 g/lperm (permeance) 57.4 ng/(s•m2•Pa)perm inch (permeability) 1.46 ng/(s•m•Pa)pint (liquid, USA) 473 mlppm (per mass) *1.00 mg/kgpsi 6.89 kPaquad 1.055 EJquart (liquid, USA) 0.946 lrefrigeration ton (12,000Btu/h) 3.52 kWsquare (100ft2) 9.29 m2
square-feet watt 10.8 W/m2
tablespoon (approx.) 15 mlteaspoon (approx.) 5 mltherm (USA, kilogram calorie) 105.5 MJthermie 1000 kcalton, long (2,240 Ib) 1.016 t; Mgton, short (2,000 Ib) 0.907 t; Mgtorr (1 mm Hg at 0°C) 133 Payd *0.9144 myd2 0.836 m2
yd3 0.765 m3
Tables: Unit of measurement conversion
1818
Graphs and tables
1)
It is
not n
eces
sary
whe
n th
e fla
sh p
oint
is ≥
65°C
.BT
ZLo
w su
lphu
r con
tent.
ATZ
High
sulp
hur c
onten
t.
Liquid fuels classes, specifications and test methods
Liqui
d fu
el ty
peKe
rose
neLig
ht o
ilHe
avy
oila
nd o
ther
hea
vy p
etro
lum
dist
illate
sve
ry fl
uid
BTZ
fluid
BTZ
sem
iflui
dBT
Zde
nse
ATZ
dens
e BT
ZTe
st m
etho
dsFe
atur
esUn
itA
B(1 )
(2 )(3 )
(4 )(5 )
(6 )(7 )
(8 )(9 )
(10)
Flash
poi
nt°C
≥21
>55
>65
>65
>65
>65
>65
ENI I
SO 2
719
Dens
ityat
15°C
kg/m
3fro
m 7
70 to
830
from
815
to 8
75UN
I EN
ISO
367
5Vi
scos
ity:
at 5
0°C
mm
2 /s
<21,
2fro
m 2
1,2
to 3
7,4
from
37,
5 to
91,
0>9
1>9
1UN
I EN
ISO
310
4at
50°
C°E
<3,0
from
3,0
to 5
,0fro
m 5
,1 to
12,
0>1
2>1
2UN
I EN
ISO
310
4at
40°
Cm
m2 /
sfro
m 2
,0 to
7,4
UNI E
N IS
O 3
104
Disti
llate
:at
150
°C%
(v/v)
≤2 1)
UNI E
N IS
O 3
405
at 2
10°C
% (v/
v)<9
0UN
I EN
ISO
340
5at
250
°C%
(v/v)
≥65
<65
UNI E
N IS
O 3
405
at 3
00°C
% (v/
v)≤6
0≤6
0≤6
0≤6
0≤6
0UN
I EN
ISO
340
5at
350
°C%
(v/v)
≥85
<85
<85
<85
<85
<85
UNI E
N IS
O 3
405
Wat
er a
nd se
dim
ents
% (v/
v)≤0
,05
≤0,0
5≤0
,5≤1
,0≤1
,0IS
O 3
734
Wat
er%
(v/v)
≤1,5
≤1,5
ISO
373
3Se
dim
ents
% (m
/m)
≤0,5
≤0,5
UNI E
N IS
O 3
735
Cold
filte
ring
poin
t°C
≤0UN
I EN
116
Yield
val
ue°C
≤-6
ISO
301
6Su
lphu
r%
(m/m
)≤0
,2≤0
,2≤0
,3≤1
,0≤0
,3≤1
,0≤0
,3≤1
,0≤0
,3≤4
,0≤0
,3≤1
,0UN
I EN
ISO
875
4Ca
rbon
resid
ue%
(m/m
)≤6
≤15
≤6≤1
5≤6
≤15
≤18
≤6≤1
5UN
I EN
ISO
103
70N
ickel
+ Va
nadi
umm
g/kg
≤15
≤15
≤50
≤180
≤50
≤180
≤50
≤180
≤230
≤50
≤180
UNI E
N 1
3131
Ashe
s%
(m/m
)≤0
,05
≤0,1
0≤0
,15
≤0,2
0≤0
,20
UNI E
N IS
O 6
245
PCB
mg/
kg<4
<4<4
<4<4
<4<4
UNI E
N 1
2766
-2PC
Tm
g/kg
<10
<10
<10
<10
<10
<10
<10
prEN
127
66-3
Kero
sene
Light
oil
Heav
y oi
land
oth
er h
eavy
pet
rolu
m d
istilla
tes
very
flui
dBT
Zflu
idBT
Zse
mifl
uid
BTZ
dens
e AT
Zde
nse
BTZ
AB
(1 )(2 )
(3 )(4 )
(5 )(6 )
(7 )(8 )
(9 )(10
)to
tal n
omin
al"
""
""
"ou
t put
≤3
MW
tota
l nom
inal
""
""
""
""
""
out p
ut >
3 M
Wno
min
al o
ut p
ut ≥
50 M
W"
in e
very
sing
le fu
rnac
e wh
ere
fuel
oil
"is
prod
uced
Whe
n su
lphu
r com
poun
dsar
e fix
ed o
r com
bine
ddu
ring
prod
uctio
n in
a
"
perc
enta
ge h
ighe
r tha
n 60
%re
sultin
g pr
oduc
tDo
mes
tic a
nd co
mm
ercia
l app
licat
ions
""
""
""
Industrial applications
1919
Graphs and tablesC
UR
VE
1-
LIG
HT
OIL
CU
RV
E 2
- V
ER
Y F
LUID
CU
RV
E 3
- F
LUID
3/5
CU
RV
E 4
- F
LUID
5/7
CU
RV
E 5
- D
EN
SE
8C
UR
VE
6-
DE
NS
E 1
5 -
20C
UR
VE
7-
V
ISC
OS
. 24
EN
GI.E
R A
T 5
0°C
CU
RV
E 8
- V
ISC
OS
. 35
EN
GI.E
R A
T 5
0°C
CU
RV
E 9
- V
ISC
OS
. 50
EN
GI.E
R A
T 5
0°C
CU
RV
E 1
0- V
ISC
OS
. 85
EN
GI.E
R A
T 5
0°C
pu
mp
ing
lim
it
Vis
cosi
ty r
ang
e fo
r at
om
isin
g
TE
MP
ER
AT
UR
E
VISCOSITYSAYBOLT UNIVERSAL SECONDS
°F
REDWOOD I, SECONDS
ENGLER, DEGREES
KINEMATIC, CENTISTOKESViscosity-temperature curves for heavy oils
2020
Graphs and tables
*) For a load loss of 1 mbar, the capacities must be increased by 45%; for a load loss of 2 mbar, the capacities must be increased by 110%.
Capacity in volume (m3/h a 15°C) for natural gas, density 0.6, calculated for steel pipes,with load loss of 1.0 mbar
Outer diameter 3/8 GAS 1/2 GAS 3/4 GAS 1 GAS 1 1/4 GAS 1 1/2 GAS 2 GAS 2 1/2 GAS 3 GASInner diameter *) mm 13.2 16.6 22.2 27.9 36.6 42.5 53.8 69.6 81.6
Capacities m3
2 1,50 2,70 6,00 11,0 23,0 35,0 – – –4 1,00 1,80 4,10 7,4 15,0 24,0 45,0 82 1356 0,80 1,50 3,20 6,1 12,0 19,0 35,0 66 1088 0,70 1,30 2,80 5,2 10,6 16,4 30,0 58 9210 0,60 1,10 2,60 4,7 9,5 14,5 27,0 52 8115 0,50 0,90 2,00 3,8 7,6 11,5 21,5 43 6520 0,40 0,78 1,70 3,2 6,4 9,8 18,4 36 5525 0,32 0,69 1,50 2,9 5,7 8,7 16,1 32 4930 – 0,62 1,40 2,6 5,1 8,0 14,7 29 4540 – 0,55 1,20 2,2 4,5 6,8 12,5 25 3850 – 0,46 1,05 2,0 3,8 6,1 11,1 22 3460 – – – 1,8 3,5 5,5 10,0 20 3080 – – – 1,5 3,0 4,6 8,6 17 26100 – – – – 2,7 4,2 7,6 15 23
Virtu
al le
ngth
m
Outer diameter 3/8 GAS 1/2 GAS 3/4 GAS 1 GAS 1 1/4 GAS 1 1/2 GAS 2 GAS 2 1/2 GAS 3 GASInner diameter mm 13.2 16.6 22.2 27.9 36.6 42.5 53.8 69.6 81.6Thickness mm 2.0 2.3 2.3 2.9 2.9 2.9 3.2 3.2 3.6
Capacities m3/h2 3,09 5,89 13,04 24,13 50,82 76,58 145,15 288,70 441,424 2,09 3,99 8,82 16,31 30,34 51,72 99,19 197,75 302,276 1,66 3,17 7,02 12,97 27,29 41,10 78,79 158,46 242,178 1,41 2,70 5,96 11,02 23,18 34,90 66,91 135,24 206,9110 1,25 2,38 5,25 9,71 20,42 30,75 58,94 119,11 183,1315 0,99 1,89 4,18 7,71 16,22 24,42 46,79 94,55 146,0120 0,84 1,61 3,55 6,55 13,77 20,73 39,72 80,25 123,9225 0,74 1,41 3,12 5,77 12,13 18,26 34,98 70,66 109,1030 0,67 1,28 2,82 5,20 10,93 16,46 31,53 63,68 98,3240 0,57 1,08 2,39 4,42 9,28 13,97 26,76 54,04 83,4350 0,50 0,95 2,11 3,89 8,17 12,30 23,56 47,58 73,4575 0,40 0,76 1,67 3,09 6,49 9,76 18,69 37,74 58,26100 0,34 0,64 1,42 2,62 5,50 8,28 15,86 32,02 49,42
Virtu
al le
ngth
m
Capacity in volume (consumption) (m3/h) for propane (LPG) with density of 1.56,calculated for a max. load loss of 0.5 mbar.
2121
Graphs and tables
Combustion air for combustible towns
Note:Clearly, the combustion air is related to the calorific power of the fuel.
Fuel P.C.I. (lower calorific power) CO2% Practice CO2% Theory Max. Opacity Max. CO% O2% Practice
Light oil 10,200 kcal/kg 10 - 13 15,44 2 0,1 3 - 7Heavy oil (5°E at 50°C) 9,600 kcal/kg 10 - 13 16,12 6 0,1 4 - 8Heavy oil (above 5°E at 50°C) 9,300 kcal/kg 10 - 13 16,12 6 0,1 4 - 8Methane (CH4) 8,550 kcal/mn
3 8 - 10 11,61 – 0,1 3 - 7LPG = Propane (C3 H8) 22,000 kcal/mn
3 10 - 12 13,80 – 0,1 3 - 6Town Gas 4,500 kcal/mn
3 8 - 10 – – 0,1 –
Theory Practice Fuel m3/m3 m3/m3
or orm3/kg m3/kg
Methane 9,6 12,0Propane (GPL) 23,8 32,0Butane (GPL) 30,9 41,7Light oil 11,3 15,7Heavy oil 10,8 15,0
Combustion features for liquid fuels
Designation.Outer Inner
Thickness Weightby convention
diameter diametermm mm mm kg/m
1/4 13,5 8,8 2,35 0,653/8 17,2 12,5 2,35 0,851/2 21,3 16,0 2,65 1,223/4 26,9 21,6 2,65 1,581 33,7 27,2 3,25 2,44
1 1/4 42,4 35,9 3,25 3,141 1/2 48,3 41,8 3,25 3,61
2 60,3 53,0 3,65 5,102 1/2 76,1 68,8 3,65 6,51
3 88,9 80,8 4,05 8,474 114,3 105,3 4,50 12,15 139,7 130,0 4,85 16,26 165,1 155,4 4,85 19,2
Pipes for the gas thread , medium series, according to Norms UNI 8863
2222
Graphs and tables
°C °F °C °F °C °F °C °F– 20 – 4,0 – 3 26,6 + 11 + 51,8 28 82,4– 19 – 2,2 – 2 28,4 12 53,6 29 84,2– 18 – 0,4 – 1 30,2 13 55,4 30 86,0– 17 + 1,4 0 32,0 14 57,2 35 95– 16 3,2 + 1 33,8 15 59,0 40 104– 15 5,0 2 35,6 16 30,8 45 113– 14 6,8 3 37,4 17 62,6 50 122– 13 8,6 4 39,2 18 64,4 55 131– 12 10,4 5 41,0 19 66,2 60 140– 11 12,2 6 42,8 20 68,0 65 149– 10 14,0 7 44,6 21 69,8 70 158– 9 15,8 8 46,4 22 71,6 75 167– 8 17,6 9 48,2 23 73,4 80 176– 7 19,4 10 50,0 24 75,2 85 185– 6 21,2 25 77,0 90 194– 5 23,0 26 78,8 95 203– 4 24,8 27 80,6 100 212
Average temperature Size (mm. of water column Height of the flue above the combustion chamber mid point in metresof gas in flue for every metre of height) 15 18 20 25 30 35 40 45 50
120 0,277 4,1 4,9 5,5 6,9 8,3 9,6 11,0 12,4 13,8140 0,317 4,7 5,7 6,3 7,9 9,5 11 12,6 14,2 15,8160 0,360 5,4 6,4 7,2 9 10,8 12,6 14,4 16,2 18180 0,395 5,9 7,1 7,9 9,8 11,8 13,8 15,8 17,7 19,7200 0,425 6,3 7,6 8,5 10,6 12,7 14,8 17 19,1 21,1220 0,458 6,8 8,2 9,1 11,4 13,7 16 18,3 0,6 22,9240 0,486 7,2 8,7 9,7 12,1 14,5 17 19,4 21,8 24,3260 0,515 7,7 9,2 10,3 12,8 15,4 18 20,6 23,1 25,7280 0,535 8 9,6 10,7 13,3 16 18,7 21,4 24 26,7300 0,557 8,3 10 11,1 13,9 16,7 19,4 22,2 25 27,8320 0,577 8,6 10,3 11,5 14,4 17,3 20,1 23 25,9 28,8340 0,599 8,9 10,7 11,9 14,9 17,9 20,9 23,9 26,9 29,9360 0,619 9,2 11,1 12,3 15,4 18,5 21,6 24,7 27,8 30,9380 0,635 9,5 11,4 12,7 15,8 19 22,2 25,4 28,5 31,7400 0,649 9,7 11,6 12,9 16,1 19,4 22,7 25,9 29,2 32,4
Flue Draught
Temperature Conversion Tables (°C - °F)
2323
Graphs and tables
Minimum Motor at full load size of
delayed fuse
HP kW ηη% cos ϕϕAmp. in Amperes
V 230 V 400 V 230 V 4000,25 0,18 64 0,77 1,00 0,58 2 20,35 0,25 68 0,78 1,28 0,74 2 20,50 0,37 69 0,78 1,79 1,03 4 20,75 0,55 72 0,80 2,52 1,46 6 21,00 0,75 73 0,83 3,20 1,85 8 41,50 1,10 75 0,84 4,60 2,65 10 62,00 1,50 77 0,86 5,90 3,40 16 83,00 2,20 80 0,85 8,50 5,00 25 10
Minimum Motor at full load size of
delayed fuse
HP kW ηη% cos ϕϕAmp. in Amperes
V 230 V 400 V 230 V 4004,00 3,00 81 0,87 11,10 6,40 35 165,50 4,00 83 0,86 14,90 8,60 40 257,50 5,50 85 0,89 19,20 11,10 63 3510,00 7,50 86 0,89 25,20 14,60 80 4012,50 9,00 87 0,89 31,00 18,00 100 6315,00 11,00 87 0,88 38,00 22,00 125 6320,00 15,00 87 0,88 50,60 29,30 160 10025,00 18,50 88 0,89 67,80 35,70 200 125
Table: absorption and dimensioning of fuses for three-phase electrical motors at 2800 RPM (2-pin)
0,01 6,7 131,7 0,0076 6,73 600,1 593,4 2,14470,02 17,2 68,28 0,0465 17,24 604,8 587,5 2,08470,04 28,6 35,46 0,02820 28,65 609,8 581,1 2,02530,06 35,8 24,10 0,04134 35,81 312,9 577,1 1,99080,08 41,2 18,45 0,05421 41,14 615,2 574,1 1,96640,10 45,4 14,95 0,06688 45,41 617,0 571,5 1,94780,12 49,1 12,60 0,07938 49,01 618,5 569,5 1,93260,14 52,2 10,89 0,09177 52,13 619,9 567,8 1,91970,16 54,9 9,612 0,1040 54,88 621,1 566,2 1,90870,18 57,4 8,605 0,1162 57,36 622,1 564,7 1,88900,20 59,7 7,795 0,1283 59,61 623,1 563,5 1,88030,25 64,6 6,322 0,1582 64,49 625,1 560,6 1,87180,30 68,7 5,328 0,1877 98,61 626,8 558,2 1,85670,35 72,3 4,614 0,2169 72,27 628,0 556,0 1,84430,40 75,4 4,069 0,2458 75,36 629,5 554,1 1,83340,50 80,9 3,301 0,3029 80,81 631,6 550,8 1,81500,60 85,5 2,783 0,3594 85,4 633,4 548,0 1,80010,70 89,5 2,400 0,4152 89,43 634,9 545,5 1,78740,80 93,0 2,125 0,4705 92,99 636,2 543,2 1,77670,90 96,2 1,904 0,5253 96,19 637,4 541,2 1,76731,00 99,1 1,725 0,5797 99,12 638,5 539,4 1,75871,10 101,8 1,578 0,6337 101,81 639,4 537,6 1,75101,20 104,3 1,455 0,6876 104,32 640,3 536,0 1,74401,30 106,6 1,350 0,7410 106,66 641,3 534,5 1,73151,40 108,7 1,259 0,7942 108,85 642,0 533,1 1,73151,50 110,8 1,180 0,8472 110,92 642,8 531,9 1,72601,60 112,7 1,111 0,8990 112,89 643,5 530,6 1,72001,70 114,6 1,050 0,9524 114,76 644,1 529,3 1,71611,80 116,3 0,9952 1,005 115,64 644,7 528,2 1,71151,90 118,0 0,9460 1,057 118,24 645,3 527,1 1,70712,00 119,6 0,9016 1,100 119,87 645,8 525,9 1,70292,20 122,6 0,8240 1,213 122,9 646,8 523,0 1,69522,40 125,5 0,7601 1,310 125,8 647,8 522,0 1,68842,60 128,1 0,7052 1,418 128,5 648,7 520,2 1,68192,80 130,5 0,6578 1,520 131,0 649,5 518,5 1,6759
Pres
sure
kg
/cm
2
Tem
pera
ture
°C
Spec
ific
Volu
me
m3 /
kg
Spec
ific
Wei
ght
kg/m
3
Heat
of
liqu
idca
l/kg
Heat
cont
ent
cal/
kg
Evap
orat
ion
heat
cal/
kg
Entro
pyca
l/kg
°C
Pres
sure
kg
/cm
2
Tem
pera
ture
°C
Spec
ific
Volu
me
m3 /
kg
Spec
ific
Wei
ght
kg/m
3
Heat
of
liqu
id
cal/
kg
Heat
cont
ent
cal/
kg
Evap
orat
ion
heat
cal/
kg
Entro
pyca
l/kg
°C
3,00 132,0 0,6166 1,622 133,4 650,3 516,9 1,67033,20 135,1 0,5804 1,723 135,6 650,9 515,3 1,66503,40 137,2 0,5483 1,824 137,8 651,6 513,8 1,66013,60 139,2 0,5196 1,925 139,8 652,2 512,4 1,65573,80 141,1 0,4939 2,026 141,8 652,8 511,0 1,65144,00 142,9 0,4706 2,125 143,6 653,4 509,8 1,64744,20 144,7 0,4495 2,225 145,4 653,9 508,5 1,64354,40 146,4 0,4303 2,324 147,2 654,4 507,2 1,63984,60 148,0 0,4127 2,423 148,9 654,9 506,0 1,63624,80 149,6 0,3965 2,522 150,5 655,4 504,9 1,63295,00 151,1 0,3816 2,621 152,1 655,8 503,7 1,62075,50 154,7 0,3489 2,867 155,8 656,9 501,1 1,62206,00 158,1 0,3213 3,112 159,2 657,8 498,5 1,61516,50 161,2 0,2980 3,356 162,5 658,6 496,1 1,60887,00 164,2 0,2778 3,600 165,6 659,4 493,8 1,60297,50 167 0,2603 3,842 168,5 660,1 491,7 1,59738,00 169,6 0,2448 4,085 171,3 660,8 489,5 1,59228,50 172,1 0,2311 4,326 173,9 661,4 487,5 1,58759,00 174,5 0,2180 4,568 176,4 662,0 485,6 1,58279,50 176,8 0,2080 4,809 178,8 662,5 483,6 1,578210,00 179 0,1981 5,040 181,2 663 481,8 1,574011,00 183,2 0,1808 5,530 185,6 663,9 478,3 1,566112,00 187,1 0,1664 6,010 189,8 664,7 475,0 1,559213,00 190,7 0,1541 6,486 193,5 665,4 471,0 1,552014,00 194,1 0,1485 6,967 197,1 666,0 468,9 1,540415,00 197,4 0,1343 7,446 200,5 666,6 466,0 1,540616,00 200,4 0,1262 7,925 203,9 667,1 463,2 1,535117,00 203,4 0,1190 8,405 207,1 667,6 460,4 1,530018,00 206,1 0,1126 8,886 210,1 667,9 457,8 1,525119,00 208,8 0,1068 9,366 213,0 668,2 455,2 1,520520,00 211,2 0,1016 9,846 215,8 668,5 452,7 1,514022,00 216,2 0,09251 10,81 221,3 668,9 447,7 1,507824,00 220,8 0,08492 11,78 226,1 669,3 443,2 1,500026,00 225,0 0,07846 12,75 230,8 669,5 438,7 1,492628,00 229,0 0,07288 13,72 235,2 669,6 434,4 1,485730,00 232,8 0,06802 14,70 239,5 669,7 430,2 1,4793
Saturated water vapour
26
0002922210-T
EX
P
Optionals
1) Equipped with air closure device.2) Equipped with light oil pre-heater with drop-stop device.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Series BTL from 16,6 to 42,7 kWSingle-stage light oil burners
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Single stage operation (on/off).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without havingto remove the burner from the boiler.
• Manual air flow adjustment.• When using biodiesel light oil (fuel of vegetable
origin), the burner must be built with specificcomponents: flexible hoses, line filter and pump.
• Equipped with one 7 pole connector, one flangeand one insulating seal for boiler fastening, 2flexible hoses, one line filter and one nozzle.
• On request: longer blast tube, operation onbiodiesel.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air inlet with device to adjust the air
flow; automatically closing air gate.• Sliding coupling flange to adapt the head
protrusion to the various types of boilers (with theexception of BTL 3, BTL 3H).
• Adjustable combustion head complete with steelblast tube and deflector disk.
• Monophase electric motor to run fan and pump.• Gear pump with pressure regulator and fuel stop-
cock valve.• Variable output fuel preheater (H version).• Automatic control and command equipment for
the burner compliant with European standardEN230.
• Flame detection by photoresistance.• 7 pole outlet for burner electrical and thermostat
supply.• Electrical protection rating IP40.• Sound-proof plastic protective cover.
0002
2706
60-T
D
B
A C
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
Description200 mm long combustion head for BTL 0-0H-3-3HBiodiesel operation
Line filter - Flex hoses - Nozzle - Boiler coupling kit - 7 pin plug
Light oil burner accessories
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
17,8 ÷ 42,7 BTL 3 35450010 1,5 1N AC 50Hz 230V 0,09 250 217,5 330 90 80 400 x 280 x 280 9 1)
16,6 ÷ 42,7 BTL 3 H 35450011 1,5 1N AC 50Hz 230V 0,09 250 217,5 330 90 80 400 x 280 x 280 9 1) 2)
21,3 ÷ 42,7 BTL 0 35470010 1,5 1N AC 50Hz 230V 0,11 245 270 410 50 ÷ 105 80 540 x 300 x 320 12 1)
18,6 ÷ 42,7 BTL 0 H 35470011 1,5 1N AC 50Hz 230V 0,11 245 270 410 50 ÷ 105 80 540 x 300 x 320 12 1) 2)
Frequency 50 Hz
Frequency 60 Hz17,8 ÷ 42,7 BTL 3 35450010 1,5 1N AC 60Hz 230V 0,09 250 217,5 330 90 80 400 x 280 x 280 9 1)
16,6 ÷ 42,7 BTL 3 H 35450011 1,5 1N AC 60Hz 230V 0,09 250 217,5 330 90 80 400 x 280 x 280 9 1) 2)
21,3 ÷ 42,7 BTL 0 35470010 1,5 1N AC 60Hz 230V 0,11 245 270 410 50 ÷ 105 80 540 x 300 x 320 12 1)
18,6 ÷ 42,7 BTL 0 H 35470011 1,5 1N AC 60Hz 230V 0,11 245 270 410 50 ÷ 105 80 540 x 300 x 320 12 1) 2)
Light oil
27
Optionals
1) Equipped with air closure device.2) Equipped with light oil pre-heater with drop-stop device.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Series BTL from 26 to 118 kWSingle-stage light oil burners
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Single stage operation (on/off).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without havingto remove the burner from the boiler.
• Manual air flow adjustment.• When using biodiesel light oil (fuel of vegetable
origin), the burner must be built with specificcomponents: flexible hoses, line filter and pump.
• Equipped with one 7 pole connector, one flangeand one insulating seal for boiler fastening, 2flexible hoses, one line filter and one nozzle.
• On request: longer blast tube, operation onbiodiesel.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air inlet with device to adjust the air
flow; automatically closing air gate.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable combustion head complete with steel
blast tube and deflector disk.• Monophase electric motor to run fan and pump.• Gear pump with pressure regulator and fuel stop-
cock valve.• Variable output fuel preheater (only BTL 4H).• Automatic control and command equipment for
the burner compliant with European standardEN230.
• Flame detection by photoresistance.• 7 pole outlet for burner electrical and thermostat
supply.• Electrical protection rating IP40.• Sound-proof plastic protective cover.
0002
2706
60-T
D
B
A C
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
Description200 mm long combustion head for BTL 4-4H250 mm long combustion head for BTL 6-6H-10-10HBiodiesel operation
Line filter - Flex hoses - Nozzle - Boiler coupling kit - 7 pin plug
Light oil burner accessories
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E a 20°C
Frequency 50 Hz
Frequency 60 Hz
26 ÷ 56,1 BTL 4 35490010 1,5 1N AC 50Hz 230V 0,11 245 270 410 50 ÷ 105 80 540 x 300 x 320 12 1)
26 ÷ 56,1 BTL 4 H 35490011 1,5 1N AC 50Hz 230V 0,11 245 270 410 50 ÷ 105 80 540 x 300 x 320 12 1) 2)
31,9 ÷ 74,3 BTL 6 35510010 1,5 1N AC 50Hz 230V 0,11 245 270 455 50 ÷ 150 90 540 x 300 x 320 12 1)
31,9 ÷ 74,3 BTL 6 H 35510011 1,5 1N AC 50Hz 230V 0,11 245 270 455 50 ÷ 150 90 540 x 300 x 320 12 1) 2)
60,2 ÷ 118 BTL 10 35530010 1,5 1N AC 50Hz 230V 0,11 245 270 480 70 ÷ 158 90 540 x 300 x 320 12 1)
60,2 ÷ 118 BTL 10 H 35530011 1,5 1N AC 50Hz 230V 0,11 245 270 480 70 ÷ 158 90 540 x 300 x 320 12 1) 2)
26 ÷ 56,1 BTL 4 35490010 1,5 1N AC 60Hz 230V 0,11 245 270 410 50 ÷ 105 80 540 x 300 x 320 12 1)
26 ÷ 56,1 BTL 4 H 35490011 1,5 1N AC 60Hz 230V 0,11 245 270 410 50 ÷ 105 80 540 x 300 x 320 12 1) 2)
31,9 ÷ 74,3 BTL 6 35510010 1,5 1N AC 60Hz 230V 0,11 245 270 455 50 ÷ 150 90 540 x 300 x 320 12 1)
31,9 ÷ 74,3 BTL 6 H 35510011 1,5 1N AC 60Hz 230V 0,11 245 270 455 50 ÷ 150 90 540 x 300 x 320 12 1) 2)
60,2 ÷ 118 BTL 10 35530010 1,5 1N AC 60Hz 230V 0,11 245 270 480 70 ÷ 158 90 540 x 300 x 320 12 1)
60,2 ÷ 118 BTL 10 H 35530011 1,5 1N AC 60Hz 230V 0,11 245 270 480 70 ÷ 158 90 540 x 300 x 320 12 1) 2)
0002922210-T
EX
P
Light oil
28
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Single stage operation (on/off).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without havingto remove the burner from the boiler.
• Manual air flow adjustment.• When using biodiesel light oil (fuel of vegetable
origin), the burner must be built with specificcomponents: flexible hoses, line filter and pump.
• Equipped with one 7 pole connector, one flangeand one insulating seal for boiler fastening, 2flexible hoses, one line filter and one nozzle.
• On request: operation on biodiesel.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air inlet with device to adjust the air
flow; automatically closing air gate (except BTL 26).• Sliding coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Monophase electric motor to run fan and pump.• Gear pump with pressure regulator and fuel stop-
cock valve.• Automatic control and command equipment for
the burner compliant with European standardEN230.
• Flame detection by photoresistance.• 7 pole outlet for burner electrical and thermostat
supply.• Electrical protection rating IP40.• Sound-proof plastic protective cover.
Series BTL from 83 to 310 kWSingle-stage light oil burners
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
OptionalsDescriptionBiodiesel operation
Line filter - Flex hoses - Nozzle - Boiler coupling kit - 7 pin plug
Light oil burner accessories
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
5
4.5
mbar
4
3.5
3
2.5
0
2
1.5
1
0.5
0002922431
26252423
310300290280270260
22
250240230220210200
212019
190180170160150140130
1817161514131211
120110
1097
90
8
10080kg/h
kW
BTL 26BTL 20BTL 20P BTL 26P
BTL 14BTL 14P
83 ÷ 166 BTL 14 35610010 1,5 1N AC 50Hz 230V 0,18 303 345 645 100 ÷ 250 100 750 x 370 x 410 18 1)
118,6 ÷ 261 BTL 20 35630010 1,5 1N AC 50Hz 230V 0,18 303 345 645 100 ÷ 250 114 750 x 370 x 410 18 1)
190 ÷ 310 BTL 26 35650010 1,5 1N AC 50Hz 230V 0,25 303 345 650 100 ÷ 255 135 750 x 370 x 410 18
83 ÷ 166 BTL 14 35615410 1,5 1N AC 60Hz 230V 0,25 303 345 645 100 ÷ 250 100 750 x 370 x 410 18 1)
118,6 ÷ 261 BTL 20 35635410 1,5 1N AC 60Hz 230V 0,25 303 345 645 100 ÷ 250 114 750 x 370 x 410 18 1)
190 ÷ 310 BTL 26 35655410 1,5 1N AC 60Hz 230V 0,25 303 345 650 100 ÷ 255 135 750 x 370 x 410 18
Frequency 50 Hz
Frequency 60 Hz
Light oil
0002
2707
60-T
CA
D
B
1) Equipped with air closure device.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Notes
NEW
29
Series SPARK 35/35W from 178 to 391 kWSingle-stage light oil burners
0002
2703
32/
7-T
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Single stage operation (on/off).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without havingto remove the burner from the boiler.
• Manual air flow adjustment.• When using biodiesel light oil (fuel of vegetable
origin), the burner must be built with specificcomponents: flexible hoses, line filter and pump.
• Equipped with one 7 pole connector, one flangeand one insulating seal for boiler fastening, 2flexible hoses, one line filter and one nozzle.
• On request: blast-pipe with greater than standardprotrusion, a device for air gate closure duringpause to avoid loss of heat up flue, biodieselrunning.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Monophase electric motor to run fan and pump.• Device made from sound-absorbing material to
reduce fan noise.• Gear pump with pressure regulator and fuel stop-
cock valve.• Automatic control and command equipment for the
burner compliant with European standard EN230.• Flame detection by photoresistance.• Start/stop switch (except the W version).• 7 pole outlet for burner electrical and thermostat
connections.• Electrical protection rating IP40.• Sound-proof plastic protective cover (except the
W version).
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
0002
2703
32/1
-T
0002
9213
35/1
-T
50 100 150 200 250 300 350 400
5 10 15 20 25 30 35
450
mbar
3.5
4.5
4
3
2.5
2
1.5
1
0.5
0 kWkg/h
Gasolio
SPARK 35-35 W
3) Soundproof lid on burner air intake.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
OptionalsDescription500 mm long combustion headAutomatic Air Closure Device Biodiesel operation
Line filter - Flex hoses - Nozzle - Boiler coupling kit - 7 pin plug
Light oil burner accessories
Notes
Part no. Description97980054 Soundproof burner cover
Accessories available on request
178 ÷ 391 SPARK 35 W 3070010 1,5 1N AC 50Hz 230V 0,37 450 372,5 780 105 ÷ 350 135 940 x 490 x 390 30 3)
178 ÷ 391 SPARK 35 3071010 1,5 1N AC 50Hz 230V 0,37 490 385 810 105 ÷ 350 135 980 x 540 x 480 34 3)
178 ÷ 391 SPARK 35 W 30705410 1,5 1N AC 60Hz 230V 0,37 450 372,5 780 105 ÷ 350 135 940 x 490 x 390 30 3)
178 ÷ 391 SPARK 35 30715410 1,5 1N AC 60Hz 230V 0,37 490 385 810 105 ÷ 350 135 980 x 540 x 480 34 3)
Frequency 50 Hz
Frequency 60 Hz
Light oil
30
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Single stage operation (on/off).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without havingto remove the burner from the boiler.
• Manual air flow adjustment.• When using biodiesel light oil (fuel of vegetable
origin), the burner must be built with specificcomponents: flexible hoses, line filter and pump.
• Equipped with one flange and one insulating sealfor boiler fastening, 2 flexible hoses, one linefilter and one nozzle.
• On request: a device for air gate closure duringpause to avoid loss of heat up flue.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan and pump.• Gear pump with pressure regulator and fuel stop-
cock valve.• Automatic control and command equipment for
the burner compliant with European standardEN230.
• Flame detection by photoresistance.• Terminal block for the electrical and thermostatic
connections to the burner.• Electrical protection rating IP40.
Serie BT...G from 237 to 712 kWSingle-stage light oil burners
BT 40 G BT 60 G1.5
1
0.5
0
15 20 25 30 35 40 45 50 55 60 Gasolio
mbar
0002
9213
34/3
-T
kWkg/h
200 250 300 350 400 450 550 600 650500 700 750
0002
2703
32/3
-T
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
OptionalsDescriptionAutomatic Air Closure Device
Line filter - Flex hoses - Nozzle - Boiler coupling kit
Light oil burner accessories
Part no. Description97980054 Soundproof burner cover for BT 4097980055 Soundproof burner cover for BT 60
Accessories available on request
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
237 ÷ 474 BT 40 G 3042010 1,5 3N AC 50Hz 400V 0,37 510 430 835 120 ÷ 180 135 1060 x 660 x 600 54
356 ÷ 712 BT 60 G 3045010 1,5 3N AC 50Hz 400V 0,75 600 510 991 160 ÷ 245 160 1070 x 720 x 710 78
237 ÷ 474 BT 40 G 30425410 1,5 3N AC 60Hz 400V 0,37 510 430 835 120 ÷ 180 135 1060 x 660 x 600 54
356 ÷ 712 BT 60 G 30455410 1,5 3N AC 60Hz 400V 0,76 600 510 991 160 ÷ 245 160 1070 x 720 x 710 78
Frequency 50 Hz
Frequency 60 Hz
Light oilNet calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Notes
31
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without havingto remove the burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• When using biodiesel light oil (fuel of vegetableorigin), the burner must be built with specificcomponents: flexible hoses, line filter and pump.
• Equipped with one 4 and 7 pole connector, oneflange and one insulating seal for boiler fastening, 2flexible hoses, one line filter and one nozzle.
• On request: longer blast tube, operation onbiodiesel.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air inlet with device to adjust the air
flow; automatically closing air gate.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable combustion head complete with steel
blast tube and deflector disk.• Monophase electric motor to run fan and pump.• Gear pump with pressure regulator and fuel stop-
cock valves.• Automatic control and command equipment for
the burner compliant with European standardEN230.
• Flame detection by photoresistance.• 7 pole outlet for burner electrical and thermostat
connections, and 4 pole outlet for second stagecontrol.
• Electrical protection rating IP40.• Sound-proof plastic protective cover.
Serie BTL...P from 26 to 118 kWTwo-stage light oil burners
0002922210/1
-T
Gasolio
0002
2706
60-T
D
B
A C
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
1) Equipped with air closure device.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
OptionalsDescription200 mm long combustion head for BTL 4250 mm long combustion head for BTL 6-10Biodiesel operation
Line filter - Flex hoses - Nozzle - Boiler coupling kit - 4 and 7 pin plug
Light oil burner accessories
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
26 ÷ 56,1 BTL 4 P 35500010 1,5 1N AC 50Hz 230V 0,11 245 270 410 50 ÷ 105 80 540 x 300 x 320 12 1)
31,9 ÷ 74,3 BTL 6 P 35520010 1,5 1N AC 50Hz 230V 0,11 245 270 455 50 ÷ 150 90 540 x 300 x 320 12 1)
60,2 ÷ 118 BTL 10 P 35540010 1,5 1N AC 50Hz 230V 0,11 245 270 480 70 ÷ 158 90 540 x 300 x 320 12 1)
26 ÷ 56,1 BTL 4 P 35500010 1,5 1N AC 60Hz 230V 0,11 245 270 410 50 ÷ 105 80 540 x 300 x 320 12 1)
31,9 ÷ 74,3 BTL 6 P 35520010 1,5 1N AC 60Hz 230V 0,11 245 270 455 50 ÷ 150 90 540 x 300 x 320 12 1)
60,2 ÷ 118 BTL 10 P 35540010 1,5 1N AC 60Hz 230V 0,11 245 270 480 70 ÷ 158 90 540 x 300 x 320 12 1)
Frequency 50 Hz
Frequency 60 Hz
Light oil
32
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without havingto remove the burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• When using biodiesel light oil (fuel of vegetableorigin), the burner must be built with specificcomponents: flexible hoses, line filter and pump.
• Equipped with one 4 and 7 pole connector, oneflange and one insulating seal for boiler fastening, 2flexible hoses, one line filter and one nozzle.
• On request: operation on biodiesel.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air inlet with device to adjust the air
flow; automatically closing air gate (except BTL 26P).• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable combustion head complete with steel
blast tube and deflector disk.• Monophase electric motor to run fan and pump.• Gear pump with pressure regulator and fuel stop-
cock valves.• Automatic control and command equipment for
the burner compliant with European standardEN230.
• Flame detection by photoresistance.• 7 pole outlet for burner electrical and thermostat
connections, and 4 pole outlet for second stagecontrol.
• Electrical protection rating IP40.• Sound-proof plastic protective cover.
Serie BTL...P from 83 to 310 kWTwo-stage light oil burners
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
5
4.5
mbar
4
3.5
3
2.5
0
2
1.5
1
0.5
0002922431
26252423
310300290280270260
22
250240230220210200
212019
190180170160150140130
1817161514131211
120110
1097
90
8
10080kg/h
kW
BTL 26BTL 20BTL 20P BTL 26P
BTL 14BTL 14P
OptionalsDescriptionBiodiesel operation
Line filter - Flex hoses - Nozzle - Boiler coupling kit - 4 and 7 pin plug
Light oil burner accessories
1) Equipped with air closure device.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
83 ÷ 166 BTL 14 P 35620010 1,5 1N AC 50Hz 230V 0,18 303 345 645 100 ÷ 250 100 750 x 370 x 410 18 1)
118,6 ÷ 261 BTL 20 P 35640010 1,5 1N AC 50Hz 230V 0,18 303 345 645 100 ÷ 250 114 750 x 370 x 410 18 1)
190 ÷ 310 BTL 26 P 35660010 1,5 1N AC 50Hz 230V 0,25 303 345 650 100 ÷ 255 135 750 x 370 x 410 18
Frequency 50 Hz
Frequency 60 Hz
0002
2707
60-T
CA
D
B
NEW
83 ÷ 166 BTL 14 P 35625410 1,5 1N AC 60Hz 230V 0,25 303 345 645 100 ÷ 250 100 750 x 370 x 410 18 1)
118,6 ÷ 261 BTL 20 P 35645410 1,5 1N AC 60Hz 230V 0,25 303 345 645 100 ÷ 250 114 750 x 370 x 410 18 1)
190 ÷ 310 BTL 26 P 35665410 1,5 1N AC 60Hz 230V 0,25 303 345 650 100 ÷ 255 135 750 x 370 x 410 18
BTL 26P Available from May 2005
33
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without havingto remove the burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• When using biodiesel light oil (fuel of vegetableorigin), the burner must be built with specificcomponents: flexible hoses, line filter and pump.
• Equipped with one 4 and 7 pole connector, oneflange and one insulating seal for boiler fastening, 2flexible hoses, one line filter and 2 nozzles.
• On request: longer blast tube, operation onbiodiesel.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Monophase electric motor to run fan and pump.• Device made from sound-absorbing material to
reduce fan noise.• Gear pump with pressure regulator and fuel stop-
cock valves.• Automatic control and command equipment for the
burner compliant with European standard EN230.• Flame detection by photoresistance.• Start/stop switch, 1st /2nd stage selector (except
the W version).• 7 pole outlet for burner electrical and thermostat
connections, and 4 pole outlet for second stage control.• Electrical protection rating IP40.• Sound-proof plastic protective cover (except the
W version).
Serie SPARK 35DSG/35DSGW from 178 to 391 kWTwo-stage light oil burners
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
0002
2703
32/
7-T
0002
2703
32/1
-T
BT82
54_9
/2-T
200100 15050
5 10 15 20 25 30 35 40
300250 350 450400 5000
1
2
3
4
5
6
7
mbar SPARK 35 DSG-DSGW
kW
kg/hGasolio
3) Soundproof lid on burner air intake.4) Equipped with automatic device for air closing.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
OptionalsDescription500 mm long combustion headBiodiesel operation
Line filter - Flex hoses - Nozzles - Boiler coupling kit - 4 and 7 pin plug
Light oil burner accessories
Notes
Part no. Description97980054 Soundproof burner cover
Accessories available on request
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
178 ÷ 391 SPARK 35 DSGW 3075010 1,5 1N AC 50Hz 230V 0,37 450 372,5 780 105 ÷ 350 135 940 x 490 x 390 32 3) 4)
178 ÷ 391 SPARK 35 DSG 3076010 1,5 1N AC 50Hz 230V 0,37 490 385 810 105 ÷ 350 135 980 x 540 x 480 36 3) 4)
178 ÷ 391 SPARK 35 DSGW 30755410 1,5 1N AC 60Hz 230V 0,37 450 372,5 780 105 ÷ 350 135 940 x 490 x 390 32 3) 4)
178 ÷ 391 SPARK 35 DSG 30765410 1,5 1N AC 60Hz 230V 0,37 490 385 810 105 ÷ 350 135 980 x 540 x 480 36 3) 4)
Frequency 50 Hz
Frequency 60 Hz
Light oil
34
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without havingto remove the burner from the boiler.
• Air flow regulation for first and second stage bymeans of hydraulic jack.
• When using biodiesel light oil (fuel of vegetableorigin), the burner must be built with specificcomponents: flexible hoses, line filter, jack and pump.
• Equipped with one flange and one insulating sealfor boiler fastening, 2 flexible hoses, one linefilter and 2 nozzles.
• On request: a device for air gate closure duringpause to avoid loss of heat up flue and biodieselrunning.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan and pump.• Gear pump with pressure regulator, fuel stop-cock
valve and safety valve.• Automatic control and command equipment for
the burner compliant with European standardEN230.
• Flame detection by photoresistance.• Control panel comprising stop/go switch, 1st/2nd
stage selector, operation and block indicator.• Terminal block for the electrical and thermostatic
connections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
Series BT...DSG and ...DSG 3V from 236 to 889 kWTwo-stage light oil burners
0002
9222
70
mbar
2.5
15
12.5
10
7.5
5
0 kW22502000
1751501251007550kg/h
250
1750150012501000750500250
BT40DSG BT55DSG BT75DSG 3V BT180DSG 3VBT120DSG 3VBT100DSG
Gasolio
0002
2703
32/3
-T
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
4) Equipped with automatic device for air closing.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
OptionalsDescriptionBiodiesel operation
Line filter - Flex hoses - Nozzles - Boiler coupling kit
Light oil burner accessories
Notes
Part no. Description97980054 Soundproof burner cover for BT 4097980055 Soundproof burner cover for BT 55-75
Accessories available on request
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
236 ÷ 531 BT 40 DSG 3074010 1,5 3N AC 50Hz 400V 0,37 525 430 985 120 ÷ 305 135 1060 x 660 x 600 57
236 ÷ 531 BT 40 DSG DACA 3074110 1,5 3N AC 50Hz 400V 0,37 525 430 985 120 ÷ 305 135 1060 x 660 x 600 57 4)
331 ÷ 652 BT 55 DSG 3077010 1,5 3N AC 50Hz 400V 1,1 600 500 1170 120 ÷ 400 135 1320 x 660 x 670 66
331 ÷ 652 BT 55 DSG DACA 3077110 1,5 3N AC 50Hz 400V 1,1 600 500 1170 120 ÷ 400 135 1320 x 660 x 670 66 4)
415 ÷ 889 BT 75 DSG 3V 3087010 1,5 3N AC 50Hz 400V 1,1 630 510 1200 170 ÷ 430 160 1320 x 660 x 670 70
415 ÷ 889 BT 75 DSG 3V DACA 3087110 1,5 3N AC 50Hz 400V 1,1 630 510 1200 170 ÷ 430 160 1320 x 660 x 670 70 4)
236 ÷ 531 BT 40 DSG 3074801 1,5 3N AC 60Hz 400V 0,76 525 430 985 120 ÷ 305 135 1060 x 660 x 600 57
236 ÷ 531 BT 40 DSG DACA 30745420 1,5 3N AC 60Hz 400V 0,76 525 430 985 120 ÷ 305 135 1060 x 660 x 600 57 4)
331 ÷ 652 BT 55 DSG 3077801 1,5 3N AC 60Hz 400V 1,3 600 500 1170 120 ÷ 400 135 1320 x 660 x 670 66
331 ÷ 652 BT 55 DSG DACA 30775420 1,5 3N AC 60Hz 400V 1,3 600 500 1170 120 ÷ 400 135 1320 x 660 x 670 66 4)
415 ÷ 889 BT 75 DSG 3V 30875410 1,5 3N AC 60Hz 400V 1,3 630 510 1200 170 ÷ 430 160 1320 x 660 x 670 70
415 ÷ 889 BT 75 DSG 3V DACA 30875420 1,5 3N AC 60Hz 400V 1,3 630 510 1200 170 ÷ 430 160 1320 x 660 x 670 70 4)
Frequency 50 Hz
Frequency 60 Hz
Light oil
35
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance made easy because the burner can
be opened without having to remove it from theboiler.
• Air flow regulation for first and second stage bymeans of hydraulic jack.
• When using biodiesel light oil (fuel of vegetableorigin), the burner must be built with specificcomponents: flexible hoses, line filter, jack and pump.
• Equipped with one insulating seal for boilerfastening, 2 flexible hoses, one line filter and 2nozzles.
• On request: a device for air gate closure duringpause to avoid loss of heat up flue and biodieselrunning.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Fixed boiler attachment flange with hinge to aid
removal of atomising unit and disc.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan and pump.• Gear pump with pressure regulator, fuel stop-cock
valve and safety valve.• Automatic control and command equipment for
the burner compliant with European standardEN230.
• Flame detection by photoresistance.• Control panel comprising stop/go switch, 1st/2nd
stage selector, operation and block indicator.• Terminal block for the electrical and thermostatic
connections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
Series BT...DSG and ...DSG 3V from 236 to 889 kWTwo-stage light oil burners with hinge
0002
9222
70
mbar
2.5
15
12.5
10
7.5
5
0 kW22502000
1751501251007550kg/h
250
1750150012501000750500250
BT40DSG BT55DSG BT75DSG 3V BT180DSG 3VBT120DSG 3VBT100DSG
Gasolio
BT94
19_2
-T.EX
P
C
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
OptionalsDescriptionBiodiesel operation
Line filter - Flex hoses - Nozzles - Boiler coupling kit
Light oil burner accessories
Part no. Description97980054 Soundproof burner cover for BT 4097980055 Soundproof burner cover for BT 55-75
Accessories available on request
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
Frequency 50 Hz
Frequency 60 Hz
236 ÷ 531 BT 40 DSG Hinged 3074011 1,5 3N AC 50Hz 400V 0,37 525 445 740 145 135 1060 x 660 x 600 57
331 ÷ 652 BT 55 DSG Hinged 3077011 1,5 3N AC 50Hz 400V 1,1 600 515 805 145 135 1100 x 750 x 720 66
415 ÷ 889 BT 75 DSG 3V Hinged 3087011 1,5 3N AC 50Hz 400V 1,1 630 515 890 230 170 1100 x 750 x 720 70
236 ÷ 531 BT 40 DSG Hinged 30745411 1,5 3N AC 60Hz 400V 0,76 525 445 740 145 135 1060 x 660 x 600 57
331 ÷ 652 BT 55 DSG Hinged 30775411 1,5 3N AC 60Hz 400V 1,3 600 515 805 145 135 1100 x 750 x 720 66
415 ÷ 889 BT 75 DSG 3V Hinged 30875411 1,5 3N AC 60Hz 400V 1,3 630 515 890 230 170 1100 x 750 x 720 70
Light oilNet calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Notes
36
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without havingto remove the burner from the boiler.
• Regulation of air flow rate for first and secondstage via hydraulic piston; for BT 180 electricservomotor for first and second stage withdamper closure on standby to prevent in-flue heatdispersion.
• When using biodiesel light oil (fuel of vegetableorigin), the burner must be built with specificcomponents: flexible hoses, line filter, jack exceptBT 180) and pump.
• Equipped with one flange and one insulating sealfor boiler fastening, 2 flexible hoses, one linefilter and 2 nozzles.
• On request: a device for air gate closure duringpause to avoid loss of heat up flue except BT180) and biodiesel running.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan and pump.• Gear pump with pressure regulator, fuel stop-cock
valve and safety valve.• Automatic control and command equipment for the
burner compliant with European standard EN230.• Flame detection by photoresistance.• Control panel comprising stop/go switch, 1st/2nd
stage selector, operation and block indicator.• Terminal block for the electrical and thermostatic
connections to the burner and to control thesecond stage of.working.
• Electrical protection rating IP40.
Series BT...DSG and ...DSG 3V from 474 to 2135 kWTwo-stage light oil burners
0002
9222
70
mbar
2.5
15
12.5
10
7.5
5
0 kW22502000
1751501251007550kg/h
250
1750150012501000750500250
BT40DSG BT55DSG BT75DSG 3V BT180DSG 3VBT120DSG 3VBT100DSG
Gasolio
0002
2703
32/3
-T
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
4) Equipped with automatic device for air closing.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
OptionalsDescriptionBiodiesel operation for BT 100-120Biodiesel operation for BT 180
Line filter - Flex hoses - Nozzles - Boiler coupling kit
Light oil burner accessories
Notes
Part no. Description97980055 Soundproof burner cover for BT 100-12097980057 Soundproof burner cover for BT 180
Accessories available on request
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
533 ÷ 1186 BT 100 DSG 3090010 1,5 3N AC 50Hz 400V 1,5 640 525 1295 180 ÷ 440 195 1510 x 750 x 720 91
533 ÷ 1186 BT 100 DSG DACA 3090110 1,5 3N AC 50Hz 400V 1,5 640 525 1295 180 ÷ 440 195 1510 x 750 x 720 91 4)
474 ÷ 1660 BT 120 DSG 3V 3097010 1,5 3N AC 50Hz 400V 2,2 685 610 1400 185 ÷ 450 195 1730 x 1030 x 880 150
474 ÷ 1660 BT 120 DSG 3V DACA 3097110 1,5 3N AC 50Hz 400V 2,2 685 610 1400 185 ÷ 450 195 1730 x 1030 x 880 150 4)
712 ÷ 2135 BT 180 DSG 3V 3108010 1,5 3N AC 50Hz 400V 3 785 650 1645 200 ÷ 535 220 1730 x 1030 x 880 180 4)
533 ÷ 1186 BT 100 DSG 30905410 1,5 3N AC 60Hz 400V 2,6 640 525 1295 180 ÷ 440 195 1510 x 750 x 720 91
533 ÷ 1186 BT 100 DSG DACA 30905420 1,5 3N AC 60Hz 400V 2,6 640 525 1295 180 ÷ 440 195 1510 x 750 x 720 91 4)
474 ÷ 1660 BT 120 DSG 3V 30975510 1,5 3N AC 60Hz 400V 3,5 685 610 1400 185 ÷ 450 195 1730 x 1030 x 880 150
474 ÷ 1660 BT 120 DSG 3V DACA 30975420 1,5 3N AC 60Hz 400V 3,5 685 610 1400 185 ÷ 450 195 1730 x 1030 x 880 150 4)
712 ÷ 2135 BT 180 DSG 3V 31085510 1,5 3N AC 60Hz 400V 3,5 785 650 1645 200 ÷ 535 220 1730 x 1030 x 880 180 4)
Frequency 50 Hz
Frequency 60 Hz
Light oil
37
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance made easy because the burner can be
opened without having to remove it from the boiler.• Regulation of air flow rate for first and second
stage via hydraulic piston; for BT 180 electricservomotor for first and second stage withdamper closure on standby to prevent in-flue heatdispersion.
• When using biodiesel light oil (fuel of vegetableorigin), the burner must be built with specificcomponents: flexible hoses, line filter, jack (exceptBT 180) and pump.
• Equipped with one insulating seal for boiler fastening,2 flexible hoses, one line filter and 2 nozzles.
• On request: a device for air gate closure duringpause to avoid loss of heat up flue (except BT180) and biodiesel running.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Fixed boiler attachment flange with hinge to aid
removal of atomising unit and disc.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan and pump
with pressure regulator, fuel stop-cock valve andsafety valve.
• Automatic control and command equipment for theburner compliant with European standard EN230.
• Flame detection by photoresistance.• Control panel comprising stop/go switch, 1st/2nd
stage selector, operation and block indicator.• Terminal block for the electrical and thermostatic
connections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
Series BT...DSG and ...DSG 3V from 474 to 2135 kWTwo-stage light oil burners with hinge
0002
9222
70
mbar
2.5
15
12.5
10
7.5
5
0 kW22502000
1751501251007550kg/h
250
1750150012501000750500250
BT40DSG BT55DSG BT75DSG 3V BT180DSG 3VBT120DSG 3VBT100DSG
Gasolio
BT94
19_2
-T.EX
P
C
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
4) Equipped with automatic device for air closing.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
OptionalsDescriptionBiodiesel operation for BT 100-120Biodiesel operation for BT 180
Line filter - Flex hoses - Nozzles - Boiler coupling kit
Light oil burner accessories
Notes
Part no. Description97980055 Soundproof burner cover for BT 100-12097980057 Soundproof burner cover for BT 180
Accessories available on request
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
Frequency 50 Hz
Frequency 60 Hz
533 ÷ 1186 BT 100 DSG Hinged 3090011 1,5 3N AC 50Hz 400V 1,5 660 525 935 265 195 1100 x 750 x 720 91
474 ÷ 1660 BT 120 DSG 3V Hinged 3097011 1,5 3N AC 50Hz 400V 2,2 685 610 1040 265 195 1730 x 1030 x 880 150
712 ÷ 2135 BT 180 DSG 3V Hinged 3108011 1,5 3N AC 50Hz 400V 3 785 630 1065 290 225 1730 x 1030 x 880 180 4)
533 ÷ 1186 BT 100 DSG Hinged 30905411 1,5 3N AC 60Hz 400V 2,6 660 525 935 265 195 1100 x 750 x 720 91
474 ÷ 1660 BT 120 DSG 3V Hinged 30975511 1,5 3N AC 60Hz 400V 3,5 685 610 1040 265 195 1730 x 1030 x 880 150
712 ÷ 2135 BT 180 DSG 3V Hinged 31085511 1,5 3N AC 60Hz 400V 3,5 785 630 1065 290 225 1730 x 1030 x 880 180 4)
Light oil
38
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without havingto remove the burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• When using biodiesel light oil (fuel of vegetableorigin), the burner must be built with specificcomponents: flexible hoses, line filter and pump.
• Equipped with one flange and one insulating sealfor boiler fastening, 2 flexible hoses, one linefilter and 3 nozzles.
• On request: biodiesel operation.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan and pump.• Gear pump with pressure regulator, fuel stop-cock
valve and safety valve.• Atomisation unit with nozzle-closing pin.• Automatic control and command equipment for
the burner compliant with European standardEN230.
• Flame detection by photoresistance.• Control panel comprising stop/go switch, 1st/2nd
stage selector, operation and block indicator.• Terminal block for the electrical and thermostatic
connections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
Series BT...DSG from 873 to 4151 kWTwo-stage light oil burners
BT82
55_7
-T
kW
kg/h
Gasolio
17.5
15
12.5
10
7.5
5
2.5
0
mbar
20
22.5
25
50 100 150 200 250 300 350 400
500 1000 1500 2000 2500 3000 3500 4000 4500 5000
BT 250DSG BT 300DSG BT 350DSG
0002
2703
32/5
-T
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
4) Equipped with automatic device for air closing.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
OptionalsDescriptionBiodiesel operation
Line filter - Flex hoses - Nozzles - Boiler coupling kit
Light oil burner accessories
Notes
Part no. Description97980057 Soundproof burner cover for BT 250
Accessories available on request
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
873 ÷ 3186 BT 250 DSG 3130010 1,5 3N AC 50Hz 400V 7,5 915 780 1665 235 ÷ 590 220 1730 x 1030 x 880 225 4)
1304 ÷ 3854 BT 300 DSG 3150010 1,5 3N AC 50Hz 400V 7,5 915 840 1860 245 ÷ 605 275 2030 x 1210 x 990 265 4)
1364 ÷ 4151 BT 350 DSG 3140010 1,5 3N AC 50Hz 400V 9 1050 920 1960 350 ÷ 560 275 2260 x 1520 x 1200 310 4)
873 ÷ 3186 BT 250 DSG 3130801 1,5 3N AC 60Hz 400V 9 915 780 1665 235 ÷ 590 220 1730 x 1030 x 880 225 4)
1304 ÷ 3854 BT 300 DSG 31505410 1,5 3N AC 60Hz 400V 9 915 840 1860 245 ÷ 605 275 2030 x 1210 x 990 265 4)
1364 ÷ 4151 BT 350 DSG 31405410 1,5 3N AC 60Hz 400V 11 1050 920 1960 350 ÷ 560 275 2260 x 1520 x 1200 310 4)
Frequency 50 Hz
Frequency 60 Hz
Light oil
39
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance made easy because the burner can
be opened without having to remove it from theboiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• When using biodiesel light oil (fuel of vegetableorigin), the burner must be built with specificcomponents: flexible hoses, line filter and pump.
• Equipped with one insulating seal for boilerfastening, 2 flexible hoses, one line filter and 3nozzles.
• On request: biodiesel operation.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Fixed boiler attachment flange with hinge to aid
removal of atomising unit and disc.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan and pump.• Gear pump with pressure regulator, fuel stop-cock
valve and safety valve.• Atomisation unit with nozzle-closing pin.• Automatic control and command equipment for
the burner compliant with European standardEN230.
• Flame detection by photoresistance.• Control panel comprising stop/go switch, 1st/2nd
stage selector, operation and block indicator.• Terminal block for the electrical and thermostatic
connections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
Series BT...DSG from 873 to 4151 kWTwo-stage light oil burners with hinge
BT94
19_2
-T.EX
P
C
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
4) Equipped with automatic device for air closing.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
OptionalsDescriptionBiodiesel operation
Line filter - Flex hoses - Nozzles - Boiler coupling kit
Light oil burner accessories
Notes
Part no. Description97980057 Soundproof burner cover for BT 250
Accessories available on request
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
Frequency 50 Hz
Frequency 60 Hz
873 ÷ 3186 BT 250 DSG Hinged 3130011 1,5 3N AC 50Hz 400V 7,5 915 760 1220 290 225 1730 x 1030 x 880 225 4)
1304 ÷ 3854 BT 300 DSG Hinged 3150011 1,5 3N AC 50Hz 400V 7,5 915 805 1350 420 280 1730 x 1030 x 880 265 4)
1364 ÷ 4151 BT 350 DSG Hinged 3140011 1,5 3N AC 50Hz 400V 9 1050 885 1440 420 280 1660 x 1460 x 1230 310 4)
873 ÷ 3186 BT 250 DSG Hinged 31305411 1,5 3N AC 60Hz 400V 9 915 760 1220 290 225 1730 x 1030 x 880 225 4)
1304 ÷ 3854 BT 300 DSG Hinged 31505411 1,5 3N AC 60Hz 400V 9 915 805 1350 420 280 1730 x 1030 x 880 265 4)
1364 ÷ 4151 BT 350 DSG Hinged 31405411 1,5 3N AC 60Hz 400V 11 1050 885 1440 420 280 1660 x 1460 x 1230 310 4)
BT82
55_7
-T
kW
kg/h
Gasolio
17.5
15
12.5
10
7.5
5
2.5
0
mbar
20
22.5
25
50 100 150 200 250 300 350 400
500 1000 1500 2000 2500 3000 3500 4000 4500 5000
BT 250DSG BT 300DSG BT 350DSG
Light oil
40
Series RiNOx...L from 19 to 74 kWSingle-stage light oil burners with low pollutant emissions
0002
9219
70-T
-EX
P
1) Equipped with air closure device.2) Equipped with light oil pre-heater with drop-stop device.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Low NOx and CO emissions light oil burner
compliant with European standard EN267"Classe III".
• Single stage operation (on/off).• Suitable for working in combustion chambers
different than reverse flame.• High pressure mechanical atomisation of fuel
using nozzle.• Burnt gas recycling blast-pipe able to achieve
very low pollutant emissions, particularly withregard to nitrous oxides (NOx).
• Maintenance facilitated by the fact that theatomisation unit can be removed without havingto remove the burner from the boiler.
• Manual air flow adjustment.• Equipped with one 7 pole connector, one flange
and one insulating seal for boiler fastening, 2flexible hoses, one line filter and one nozzle.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air inlet with device to adjust the air
flow; automatically closing air gate.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Monophase electric motor to run fan and pump.• Gear pump with pressure regulator and fuel stop-
cock valve.• Variable output fuel preheater (only RINOX 35).• Automatic control and command equipment for
the burner compliant with European standardEN230.
• Flame detection by photoresistance.• 7 pole outlet for burner electrical and thermostat
connections.• Electrical protection rating IP40.• Sound-proof plastic protective cover.
Line filter - Flex hoses - Nozzle - Boiler coupling kit - 7 pin plug
Light oil burner accessories
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
0002
2706
60-T
D
B
A C
19 ÷ 40 RiNOx 35 L 35470050 1,5 1N AC 50Hz 230V 0,11 245 270 410 50 ÷ 105 80 540 x 300 x 320 12 1) 2)
38 ÷ 74 RiNOx 60 L 35510050 1,5 1N AC 50Hz 230V 0,11 245 270 455 50 ÷ 150 90 540 x 300 x 320 12 1)
Frequency 50 Hz
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
LOWNOx
Light oil
41
Series RiNOx...L2 from 38 to 190 kWTwo-stage light oil burners with low pollutant emissions
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Low NOx and CO emissions light oil burner
compliant with European standard EN267"Classe III".
• Two-stage operation (high/low flame).• Suitable for working in combustion chambers
different than reverse flame.• High pressure mechanical atomisation of fuel
using nozzle.• Combustion head (recycling of combusted gas for
RiNOx 60L2) able to achieve very low pollutantemissions, particularly with regard to nitrousoxides (NOx).
• Maintenance facilitated by the fact that theatomisation unit can be removed without havingto remove the burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• Equipped with one 4 and 7 pole connector, oneflange and one insulating seal for boilerfastening, 2 flexible hoses, one line filter and onenozzle.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air inlet with device to adjust the air
flow; automatically closing air gate.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable combustion head with blast pipe (inox
steel for RiNOx 60 L2) and steel flame disk.• Monophase electric motor to run fan and pump.• Gear pump with pressure regulator and fuel stop-
cock valves.• Automatic control and command equipment for
the burner compliant with European standardEN230.
• Flame detection by photoresistance.• 7 pole outlet for burner electrical and thermostat
connections, and 4 pole outlet for second stagecontrol.
• Electrical protection rating IP40.• Sound-proof plastic protective cover.
90
0002
9220
02
240
181512963kg/h
180.000150.000120.00090.00060.00030.000
21018015012060300 kW
kcal/h
4
3
2
1
mbar RINOX 60L2 RINOX 190L2
1) Equipped with air closure device.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Line filter - Flex hoses - Nozzle - Boiler coupling kit - 4 and 7 pin plug
Light oil burner accessories
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
0002
2706
60-T
D
B
A C
38 ÷ 74 RiNOx 60 L2 35520050 1,5 1N AC 50Hz 230V 0,11 245 270 455 50 ÷ 150 90 540 x 300 x 320 12 1)
70 ÷ 190 RiNOx 190 L2 35640050 1,5 1N AC 50Hz 230V 0,18 303 345 620 100 ÷ 250 100 750 x 660 x 600 18 1)
Frequency 50 Hz
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
LOWNOx
Light oil
NEWRiNOx 190 L2RiNOx 190 L2
42
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Low NOx and CO emissions light oil burner
compliant with European standard EN267"Classe III".
• Two-stage operation (high/low flame).• Suitable for working in combustion chambers
different than reverse flame.• High pressure mechanical atomisation of fuel
using nozzle.• Burnt gas recycling blast-pipe able to achieve
very low pollutant emissions, particularly withregard to nitrous oxides (NOx).
• Maintenance facilitated by the fact that theatomisation unit can be removed without havingto remove the burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• Equipped with one 4 and 7 pole connector, oneflange and one insulating seal for boilerfastening, 2 flexible hoses, one line filter and 2nozzles.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Monophase electric motor to run fan and pump.• Device made from sound-absorbing material to
reduce fan noise.• Gear pump with pressure regulator and fuel stop-
cock valves.• Automatic control and command equipment for the
burner compliant with European standard EN230.• Flame check by means of infrared IRD photo-
electric cell.• Start/stop switch, 1st /2nd stage selector.• 7 pole outlet for burner electrical and thermostat
connections, and 4 pole outlet for second stagecontrol.
• Electrical protection rating IP40.• Sound-proof plastic protective cover.
0002
2707
40-T
0002
9223
11-T
mbar
3020
400300200100
kcal/hx1.000
5
0
4
3
2
1
kg/h Gasolio10
400300200100kW
SPARK 35 LX
Line filter - Flex hoses - Nozzles - Boiler coupling kit - 4 and 7 pin plug
Light oil burner accessories
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
SPARK 35 LX from 118,6 to 350 kWTwo-stage light oil burners with low pollutant emissions
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
LOWNOx
118,6 ÷ 350 SPARK 35 LX 33960010 1,5 1N AC 50Hz 230V 0,37 490 380 835 165 ÷ 305 136 980 x 540 x 480 36 3) 4)
3) Soundproof lid on burner air intake.4) Equipped with automatic device for air closing.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Notes
Frequency 50 Hz
Light oil
43
Series BT...LX from 130 to 670 kWTwo-stage light oil burners with low pollutant emissions
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN267
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Low NOx and CO emissions light oil burner
compliant with European standard EN267"Classe III".
• Two-stage operation (high/low flame).• Suitable for working in combustion chambers
different than reverse flame.• High pressure mechanical atomisation of fuel
using nozzle.• Burnt gas recycling blast-pipe able to achieve
very low pollutant emissions, particularly withregard to nitrous oxides (NOx).
• Maintenance facilitated by the fact that theatomisation unit can be removed without havingto remove the burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• Equipped with one flange and one insulating sealfor boiler fastening, 2 flexible hoses, one linefilter and 2 nozzles.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan and pump.• Gear pump with pressure regulator, fuel stop-cock
valve and safety valve.• Automatic control and command equipment for
the burner compliant with European standardEN230.
• Flame check by means of infrared IRD photo-electric cell.
• Control panel comprising stop/go switch, 1st/2ndstage selector, operation and block indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
0002
9223
10
800
900
80
mbar
706050403020
800700600500400300200100
kcal/hx1.000
8
7
6
5
0
4
3
2
1
kg/h Gasolio10
700600500400300200100kW
BT 75 LXBT 40 LX
0002
2703
32/5
-T
4) Equipped with automatic device for air closing.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Line filter - Flex hoses - Nozzles - Boiler coupling kit
Light oil burner accessories
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
LOWNOx
130 ÷ 390 BT 40 LX 33970010 1,5 3N AC 50Hz 400V 0,37 525 430 985 165 ÷ 305 136 985 x 525 x 430 57 4)
270 ÷ 670 BT 75 LX 33990010 1,5 3N AC 50Hz 400V 1,1 630 610 1170 170 ÷ 430 160 1200 x 630 x 510 70 4)
Frequency 50 Hz
Light oil
44
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by
means of automatic RWF40 regulator mounted onthe control panel (to be ordered separately withthe modulation kit).
• Ability to operate with any type of combustionchamber.
• High pressure mechanical atomisation of fuelusing nozzle.
• Ability to obtain optimal combustion values byregulating combustion air and blast-pipe.
• Maintenance facilitated by the fact that theatomisation unit can be removed without havingto remove the burner from the boiler.
• Minimum and maximum air flow regulation forfirst and second stage by means of electricservomotor with pause closure of gate to preventany heat dispersion to flue.
• Equipped with one flange and one insulating sealfor boiler fastening, 2 flexible hoses and one linefilter; nozzle not included, to be orderedseparately depending on the required flow.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan and pump.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• Gear pump with pressure regulator.• Atomisation unit with magnet to control the
outlet/nozzle return pins.• Automatic control and command equipment for the
burner compliant with European standard EN230.• Flame detection by photoresistance.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximumselector, operation and block indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
Series BT...DSPG from 415 to 2135 kWProgressive/modulating two-stage light oil burners
0002
2703
32/5
-T
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEE
4) Equipped with automatic device for air closing.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
0002
9222
70-T
mbar
2.5
17.5
15
12.5
10
7.5
5
0 kW
22502000
1751501251007550kg/h
25
1750150012501000750500250
BT 75 DSPG BT 180 DSPGBT 120 DSPGBT 100 DSPG
Gasolio
Line filter - Flex hoses - Boiler coupling kit
Light oil burner accessories
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
415 ÷ 889 BT 75 DSPG 3510010 1,5 3N AC 50Hz 400V 1,1 595 510 1215 130 ÷ 450 160 1730 x 1030 x 880 140 4)
533 ÷ 1186 BT 100 DSPG 3514010 1,5 3N AC 50Hz 400V 1,5 670 525 1415 210 ÷ 400 195 1730 x 1030 x 880 150 4)
474 ÷ 1660 BT 120 DSPG 3518010 1,5 3N AC 50Hz 400V 2,2 770 610 1415 155 ÷ 500 195 1730 x 1030 x 880 175 4)
712 ÷ 2135 BT 180 DSPG 3522010 1,5 3N AC 50Hz 400V 3 815 650 1700 200 ÷ 535 220 1730 x 1030 x 880 220 4)
415 ÷ 889 BT 75 DSPG 35105410 1,5 3N AC 60Hz 400V 1,5 595 510 1215 130 ÷ 450 160 1730 x 1030 x 880 140 4)
533 ÷ 1186 BT 100 DSPG 35145410 1,5 3N AC 60Hz 400V 2,6 670 525 1415 310 ÷ 490 195 1730 x 1030 x 880 150 4)
474 ÷ 1660 BT 120 DSPG 35185410 1,5 3N AC 60Hz 400V 3,5 770 610 1415 155 ÷ 500 195 1730 x 1030 x 880 175 4)
712 ÷ 2135 BT 180 DSPG 35225410 1,5 3N AC 60Hz 400V 3,5 815 650 1700 200 ÷ 535 220 1730 x 1030 x 880 220 4)
Frequency 50 Hz
Frequency 60 Hz
Light oil
To complete the burnerNozzle with 1-3 ratio (see page 167).Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
45
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by
means of automatic RWF40 regulator mounted onthe control panel (to be ordered separately withthe modulation kit).
• Ability to operate with any type of combustionchamber.
• High pressure mechanical atomisation of fuelusing nozzle.
• Ability to obtain optimal combustion values byregulating combustion air and blast-pipe.
• Maintenance facilitated by the fact that theatomisation unit can be removed without havingto remove the burner from the boiler.
• Minimum and maximum air flow regulation forfirst and second stage by means of electricservomotor with pause closure of gate to preventany heat dispersion to flue.
• Equipped with one flange and one insulating sealfor boiler fastening, 2 flexible hoses and one linefilter; nozzle not included, to be orderedseparately depending on the required flow.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan and pump.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• Gear pump with pressure regulator.• Atomisation unit with magnet to control the
outlet/nozzle return pins.• Automatic control and command equipment for the
burner compliant with European standard EN230.• Flame detection by photoresistance.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximumselector, operation and block indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
Series BT...DSPG from 873 to 4151 kWProgressive/modulating two-stage light oil burners
BT82
55_7
/1-T
kW
kg/h
Gasolio
17.5
15
12.5
10
7.5
5
2.5
0
mbar
20
22.5
25
50 100 150 200 250 300 350 400
500 1000 1500 2000 2500 3000 3500 4000 4500 5000
BT 250DSPG BT 300DSPG BT 350DSPG
0002
2703
32/5
-T
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEE
4) Equipped with automatic device for air closing.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Line filter - Flex hoses - Boiler coupling kit
Light oil burner accessories
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
873 ÷ 3186 BT 250 DSPG 3526010 1,5 3N AC 50Hz 400V 7,5 1000 780 1700 235 ÷ 590 220 2030 x 1210 x 990 256 4)
1304 ÷ 3854 BT 300 DSPG 3530010 1,5 3N AC 50Hz 400V 7,5 1000 840 1900 245 ÷ 605 275 2030 x 1210 x 990 290 4)
1364 ÷ 4151 BT 350 DSPG 3534010 1,5 3N AC 50Hz 400V 9 1135 920 2040 350 ÷ 560 275 2030 x 1210 x 990 335 4)
873 ÷ 3186 BT 250 DSPG 35265410 1,5 3N AC 60Hz 400V 9 1000 780 1700 235 ÷ 590 220 2030 x 1210 x 990 256 4)
1304 ÷ 3854 BT 300 DSPG 35305410 1,5 3N AC 60Hz 400V 9 1000 840 1900 245 ÷ 605 275 2030 x 1210 x 990 290 4)
1364 ÷ 4151 BT 350 DSPG 35345410 1,5 3N AC 60Hz 400V 11 1135 920 2040 350 ÷ 560 275 2030 x 1210 x 990 335 4)
Frequency 50 Hz
Frequency 60 Hz
Light oil
To complete the burnerNozzle with 1-3 ratio (see page 167).Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
46
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by
means of automatic RWF40 regulator mounted onthe control panel (to be ordered separately withthe modulation kit).
• Ability to operate with any type of combustionchamber.
• High pressure mechanical atomisation of fuelusing nozzle.
• Ability to obtain optimal combustion values byregulating combustion air and blast-pipe.
• Maintenance facilitated by the fact that theatomisation unit can be removed without havingto remove the burner from the boiler.
• Minimum and maximum air flow regulation forfirst and second stage by means of electricservomotor with pause closure of gate to preventany heat dispersion to flue.
• Equipped with one flange and one insulating sealfor boiler fastening, 2 flexible hoses and one linefilter; nozzle not included, to be orderedseparately depending on the required flow.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• A three-phase electric motor to run fan and
another to run the pump.• Air pressure switch to ensure the presence of
combustion air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• Gear pump with pressure regulator.• Atomisation unit with magnet to control the
outlet/nozzle return pins.• Automatic control and command equipment for the
burner compliant with European standard EN230.• Flame detection by photoresistance.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximumselector, operation and block indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
Series GI...DSPG from 1581 to 6500 kWProgressive/modulating two-stage light oil burners
GI 510 DSPGGI 420 DSPGGI 350 DSPG
30
1
0
0
25
8
0002
9212
82/1
-T
20
15
mbar
10
5
kWx1000765432 kg/h Gasolio600500400300200100
0002
2703
32/2
-TConform to:
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
4) Equipped with automatic device for air closing.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Line filter - Flex hoses - Boiler coupling kit
Light oil burner accessories
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
1581 ÷ 4743 GI 350 DSPG 6501010 1,5 3N AC 50Hz 400V 15+2,2 1345 1010 1900 275 ÷ 500 275 2260 x 1520 x 1200 500 4)
1840 ÷ 5522 GI 420 DSPG 6506010 1,5 3N AC 50Hz 400V 18,5+2,2 1345 1040 2030 275 ÷ 560 355 2260 x 1520 x 1200 540 4)
2430 ÷ 6500 GI 510 DSPG 6511010 1,5 3N AC 50Hz 400V 18,5+3 1345 1040 2030 275 ÷ 560 355 2260 x 1520 x 1200 580 4)
1581 ÷ 4743 GI 350 DSPG 65015410 1,5 3N AC 60Hz 400V 11+2,6 1345 1010 1900 275 ÷ 500 275 2260 x 1520 x 1200 500 4)
1840 ÷ 5522 GI 420 DSPG 65065410 1,5 3N AC 60Hz 400V 13+2,6 1345 1040 2030 275 ÷ 560 355 2260 x 1520 x 1200 540 4)
2430 ÷ 6500 GI 510 DSPG 65115410 1,5 3N AC 60Hz 400V 22+3,5 1345 1040 2030 275 ÷ 560 355 2260 x 1520 x 1200 580 4)
Frequency 50 Hz
Frequency 60 Hz
Light oil
To complete the burnerNozzle with 1-3 ratio (see page 167).Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
47
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Light oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by
means of automatic RWF40 regulator mounted onthe control panel (to be ordered separately withthe modulation kit).
• Ability to operate with any type of combustionchamber.
• High pressure mechanical atomisation of fuelusing nozzle.
• Ability to obtain optimal combustion values byregulating combustion air and blast-pipe.
• Maintenance facilitated by the fact that theatomisation unit can be removed without havingto remove the burner from the boiler.
• Minimum and maximum air flow regulation forfirst and second stage by means of electricservomotor with pause closure of gate to preventany heat dispersion to flue.
• Equipped with one insulating seal for boilerfastening, 2 flexible hoses and one line filter;nozzle not included, to be ordered separatelydepending on the required flow.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Steel fan part• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Boiler coupling flange with hinge to facilitate
dismantling of the atomising unit and deflector disk.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• A three-phase electric motor to run fan and
another to run the pump.• Air pressure switch to ensure the presence of
combustion air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• Gear pump with pressure regulator.• Atomisation unit with magnet to control the
outlet/nozzle return pins.• Automatic control and command equipment for the
burner compliant with European standard EN230.• Flame detection by photoresistance.• On-board terminal box and separate control
panel comprising stop/go switch,automatic/manual and minimum/maximumselectors, operation and block indicators.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
GI 1000 DSPG from 2500 to 10500 kWProgressive/modulating two-stage light oil burners
GI 1000 DSPG30
111
0
0
25
1098
0002
9212
81/2
-T
20
15
mbar
10
5
kWx1000765432 kg/h Gasolio
900800700600500400300200100
D
A
C
B
0002
2703
32/6
-T
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEE
4) Equipped with automatic device for air closing.Net calorific value of light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Line filter - Flex hoses - Boiler coupling kit
Light oil burner accessories
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
2500 ÷ 10500 GI 1000 DSPG 6521010 1,5 3N AC 50Hz 400V 22+4 1465 1257 1710 430 490 2600 x 1710 x 1500 900 4)
Frequency 50 Hz
Light oil
To complete the burnerNozzle with 1-5 ratio (see page 167).Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
4848
Net calorific value of heavy oil: Hi = 40,19 MJ/kg = 9600 kcal/kg.
Notes
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Heavy oil burner.• Single stage operation (on/off).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without havingto remove the burner from the boiler.
• Manual air flow adjustment.• Equipped with one flange and one insulating seal
for boiler fastening, 2 flexible hoses, one linefilter and one nozzle.
• On request: a device for air gate closure duringpause to avoid loss of heat up flue.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan and pump.• Gear pump with pressure regulator and fuel stop-
cock valve.• Atomisation unit with nozzle-closing pin.• Electrical fuel preheater comprising antigas valve,
filter, thermometer, minimum and regulationthermostat.
• Automatic control and command equipment forthe burner compliant with European standardEN230.
• Flame detection by photoresistance.• Control panel including stop/go switch, operation
and block indicators, heating element operationlight.
• Terminal block for the electrical and thermostaticconnections to the burner.
• Electrical protection rating IP40.
Series BT...N from 55 to 390 kWSingle-stage heavy oil burners
BT82
46-T
kW
1.4
1.2
1
0.8
0.6
0.4
0.2
0
mbar
40 80 120 160 200 240 280 320 400 440360
BT 15 N
BT 22 N
BT 35 N
0002
3702
31-T
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEE
OptionalsDescriptionAutomatic Air Closure Device
Line filter - Flex hoses - Nozzle - Boiler coupling kit
Heavy oil burner accessories
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 50°C
55 ÷ 167 BT 15 N 2005011 5 3N AC 50Hz 400V 0,37 475 395 760 90 ÷ 180 115 1060 x 660 x 600 70
134 ÷ 245 BT 22 N 2015011 5 3N AC 50Hz 400V 0,37 475 395 790 115 ÷ 210 115 1060 x 660 x 600 70
223 ÷ 390 BT 35 N 2025011 7 3N AC 50Hz 400V 0,37 520 440 835 125 ÷ 175 135 1060 x 660 x 600 85
55 ÷ 167 BT 15 N 20055410 5 3N AC 60Hz 400V 0,37 475 395 760 90 ÷ 180 115 1060 x 660 x 600 70
134 ÷ 245 BT 22 N 20155410 5 3N AC 60Hz 400V 0,37 475 395 790 115 ÷ 210 115 1060 x 660 x 600 70
223 ÷ 390 BT 35 N 2025801 7 3N AC 60Hz 400V 0,37 520 440 835 125 ÷ 175 135 1060 x 660 x 600 85
Frequency 50 Hz
Frequency 60 Hz
4949
Series BT...SPN from 89 to 390 kWPressure-drop heavy oil burners
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEE
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Heavy oil burner.• Two-stage pressure stage operation (high/low
flame).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without havingto remove the burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• Equipped with one flange and one insulating sealfor boiler fastening, 2 flexible hoses, one linefilter and one nozzle.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan and pump.• Gear pump with pressure regulator and fuel stop-
cock valves.• Atomisation unit with nozzle-closing pin.• Electrical fuel preheater comprising antigas valve,
filter, thermometer and minimum and regulationthermostat.
• Automatic control and command equipment forthe burner compliant with European standardEN230.
• Flame detection by photoresistance.• Control panel comprising stop/go switch, 1st/2nd
stage selector, operation, block and pre-heaterindicators.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
0002
3702
31-T
0002
9217
00/1
-T
kg/hOlio C.
kW
BT 17 SPN BT 35 SPN
100 200 300 400 500
10 20 30 40
mbar6
5
4
3
2
1
0
4) Equipped with automatic device for air closing.Net calorific value of heavy oil: Hi = 40,19 MJ/kg = 9600 kcal/kg.
Line filter - Flex hoses - Nozzle - Boiler coupling kit
Heavy oil burner accessories
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 50°C
89 ÷ 189 BT 17 SPN 2040111 5 3N AC 50Hz 400V 0,37 520 440 965 118 ÷ 320 115 1060 x 660 x 600 85 4)
189 ÷ 390 BT 35 SPN 2052110 7 3N AC 50Hz 400V 0,55 520 440 985 120 ÷ 305 135 1060 x 660 x 600 85 4)
89 ÷ 189 BT 17 SPN 20405420 5 3N AC 60Hz 400V 55 520 440 965 118 ÷ 320 115 1060 x 660 x 600 85 4)
189 ÷ 390 BT 35 SPN 20525420 7 3N AC 60Hz 400V 76 520 440 985 120 ÷ 305 135 1060 x 660 x 600 85 4)
Frequency 50 Hz
Frequency 60 Hz
Heavy oil
5050
0002
3702
31-T
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Heavy oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without havingto remove the burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• When using heavy oil of viscosity up to 20°E at50°C, add the kit (to be ordered separately)consisting of: resistors for the pump, the atomisationunit and first and second stage solenoid.
• When using low sulphur heavy oil, add the kit (to beordered separately) consisting of: specific line filter,stainless steel flexible hoses and resistors for pump,atomisation unit and first and second stage solenoid.
• On request, it is possible to integrate the BT 120with a supplementary steam-operated heavy oilpre-heater: during routine operation this allowsthe fuel to be heated with the steam from theboiler, thus reducing electricity consumption.
• Equipped with one flange and one insulating seal
for boiler fastening, 2 flexible hoses, one linefilter and 2 nozzles.
• On request: steam pre-heater (only for BT 120).
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan and pump.• Gear pump with pressure regulator and fuel stop-
cock valves.• Atomisation unit with nozzle-closing pin.• Electrical fuel preheater comprising antigas valve, filter,
thermometer and minimum and regulation thermostat.• Automatic control and command equipment for the
burner compliant with European standard EN230.• Flame detection by photoresistance.• Control panel including stop/go switch, 1st/2nd
stage selector, operation and block indicators,heating element operation light.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
Series BT...DSN 4T from 223 to 1451 kWTwo-stage heavy oil burners
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEE
4) Equipped with automatic device for air closing.Net calorific value of heavy oil: Hi = 40,19 MJ/kg = 9600 kcal/kg.
Line filter - Flex hoses - Nozzles - Boiler coupling kit
Heavy oil burner accessories
Part no.Kit for heavy oil up to 20°E at 50°C98000301Kit for heavy oil with low sulphur content and max visco-sity of 15°E at 50°C98000306
OptionalsDescriptionSteam pre-heater for BT 120
Notes
BT 120 DSN 4 TBT 100 DSN 4 T
600
14
13
12
11
10
130120110100
15001400130012001100
BT 75 DSN 4 T
BT 50 DSN 4 TBT 40 DSN 4 T
9080706050403020
1000900800700600500400300200100kg/h Olio C.
mbar
9
8
7
6
5
0
4
3
2
1
10
kW
0002
9223
00-T
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 50°C
223 ÷ 446 BT 40 DSN 4T 2058010 7 3N AC 50Hz 400V 0,55 520 440 985 120 ÷ 305 135 1060 x 660 x 600 85 4)
312 ÷ 558 BT 50 DSN 4T 2061010 7 3N AC 50Hz 400V 1,1 690 535 1155 110 ÷ 375 135 1510 x 750 x 720 110 4)
446 ÷ 837 BT 75 DSN 4T 2071010 7 3N AC 50Hz 400V 1,1 690 545 1385 170 ÷ 430 160 1510 x 750 x 720 117 4)
558 ÷ 1116 BT 100 DSN 4T 2076010 7 3N AC 50Hz 400V 1,5 690 560 1320 210 ÷ 400 195 1510 x 750 x 720 120 4)
669 ÷ 1451 BT 120 DSN 4T 2081010 7 3N AC 50Hz 400V 2,2 835 610 1400 185 ÷ 450 195 1730 x 1030 x 880 180 4)
223 ÷ 446 BT 40 DSN 4T 20585410 7 3N AC 60Hz 400V 0,76 520 440 985 120 ÷ 305 135 1060 x 660 x 600 85 4)
312 ÷ 558 BT 50 DSN 4T 20615410 7 3N AC 60Hz 400V 1,5 690 535 1155 110 ÷ 375 135 1510 x 750 x 720 110 4)
446 ÷ 837 BT 75 DSN 4T 20715410 7 3N AC 60Hz 400V 1,5 690 545 1385 170 ÷ 430 160 1510 x 750 x 720 117 4)
558 ÷ 1116 BT 100 DSN 4T 20765410 7 3N AC 60Hz 400V 2,6 690 560 1320 210 ÷ 400 195 1510 x 750 x 720 120 4)
669 ÷ 1451 BT 120 DSN 4T 20815410 7 3N AC 60Hz 400V 3,5 835 610 1400 185 ÷ 450 195 1730 x 1030 x 880 180 4)
Frequency 50 Hz
Frequency 60 Hz
Heavy oil
51
Series BT...DSN 4T from 223 to 1451 kWTwo-stage heavy oil burners with hinge
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEE
4) Equipped with automatic device for air closing.Net calorific value of heavy oil: Hi = 40,19 MJ/kg = 9600 kcal/kg.
Line filter - Flex hoses - Nozzles - Boiler coupling kit
Heavy oil burner accessories
Part no.Kit for heavy oil up to 20°E at 50°C98000301Kit for heavy oil with low sulphur content and max visco-sity of 15°E at 50°C
98000306
OptionalsDescriptionSteam pre-heater for BT 120
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 50°C
Frequency 50 Hz
Frequency 60 Hz
0002
3702
21-T-
EXP
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Heavy oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance made easy because the burner can be
opened without having to remove it from the boiler.• Air flow regulation for first and second stage by
means of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• When using heavy oil of viscosity up to 20°E at50°C, add the kit (to be ordered separately)consisting of: resistors for the pump, the atomisationunit and first and second stage solenoid.
• When using low sulphur heavy oil, add the kit (to beordered separately) consisting of: specific line filter,stainless steel flexible hoses and resistors for pump,atomisation unit and first and second stage solenoid.
• On request it is possible to integrate the BT 120with a supplementary steam-operated heavy oilpre-heater: during routine operation this allowsthe fuel to be heated with the steam from theboiler, thus reducing electricity consumption.
• Equipped with one insulating seal for boiler fastening,2 flexible hoses, one line filter and 2 nozzles.
• On request: steam pre-heater (only for BT 120).
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Fixed boiler attachment flange with hinge to aid
removal of atomising unit and disc.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan and pump.• Gear pump with pressure regulator and fuel stop-
cock valves.• Atomisation unit with nozzle-closing pin.• Electrical fuel preheater comprising antigas valve, filter,
thermometer and minimum and regulation thermostat.• Automatic control and command equipment for the
burner compliant with European standard EN230.• Flame detection by photoresistance.• Control panel including stop/go switch, 1st/2nd
stage selector, operation and block indicators,heating element operation light.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
223 ÷ 446 BT 40 DSN 4T Hinged 2058011 7 3N AC 50Hz 400V 0,55 560 615 735 145 135 1060 x 810 x 1000 80 4)
312 ÷ 558 BT 50 DSN 4T Hinged 2061011 7 3N AC 50Hz 400V 1,1 660 730 835 145 135 1060 x 810 x 1000 110 4)
446 ÷ 837 BT 75 DSN 4T Hinged 2071011 7 3N AC 50Hz 400V 1,1 660 740 910 220 170 1060 x 810 x 1000 117 4)
558 ÷ 1116 BT 100 DSN 4T Hinged 2076011 7 3N AC 50Hz 400V 1,5 660 740 965 265 195 1060 x 810 x 1000 120 4)
669 ÷ 1451 BT 120 DSN 4T Hinged 2081011 7 3N AC 50Hz 400V 2,2 690 825 1125 265 195 1360 x 910 x 1140 190 4)
223 ÷ 446 BT 40 DSN 4T Hinged 20585411 7 3N AC 60Hz 400V 0,76 560 615 735 145 135 1060 x 810 x 1000 80 4)
312 ÷ 558 BT 50 DSN 4T Hinged 20615411 7 3N AC 60Hz 400V 1,5 660 730 835 145 135 1060 x 810 x 1000 110 4)
446 ÷ 837 BT 75 DSN 4T Hinged 20715411 7 3N AC 60Hz 400V 1,5 660 740 910 220 170 1060 x 810 x 1000 117 4)
558 ÷ 1116 BT 100 DSN 4T Hinged 20765411 7 3N AC 60Hz 400V 2,6 660 740 965 265 195 1060 x 810 x 1000 120 4)
669 ÷ 1451 BT 120 DSN 4T Hinged 20815411 7 3N AC 60Hz 400V 3,5 690 825 1125 265 195 1360 x 910 x 1140 190 4)
5151
BT 120 DSN 4 TBT 100 DSN 4 T
600
14
13
12
11
10
130120110100
15001400130012001100
BT 75 DSN 4 T
BT 50 DSN 4 TBT 40 DSN 4 T
9080706050403020
1000900800700600500400300200100kg/h Olio C.
mbar
9
8
7
6
5
0
4
3
2
1
10
kW
0002
9223
00-T
Heavy oil
5252
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Heavy oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without havingto remove the burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• When using heavy oil of viscosity up to 20°E at50°C, add the kit (to be ordered separately)consisting of: resistors for the pump, the atomisationunit and first and second stage solenoid.
• When using low sulphur heavy oil, add the kit (to beordered separately) consisting of: specific line filter,stainless steel flexible hoses and resistors for pump,atomisation unit and first and second stage solenoid.
• On request it is possible to add to the burner asupplementary heavy oil pre-heater using steam,which means the fuel can be heated by the steamfrom the boiler to provide an energy saving.
• Equipped with one flange and one insulating sealfor boiler fastening, 2 flexible hoses, one line
filter and 3 nozzles (2 nozzles for BT 180).• On request: steam pre-heater.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan and pump.• Gear pump with pressure regulator and fuel stop-
cock valves.• Atomisation unit with nozzle-closing pin.• Electrical fuel preheater comprising antigas valve,
filter, thermometer, regulation thermostats andminimum safety device.
• Automatic control and command equipment for theburner compliant with European standard EN230.
• Flame detection by photoresistance.• Control panel including stop/go switch, 1st/2nd
stage selector, operation and block indicators,heating element operation light.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
Series BT...DSN 4T from 725 to 3907 kWTwo-stage heavy oil burners
Olio C.
0002
9217
10-T
BT 250 DSN 4T BT 300 DSN 4T BT 350 DSN 4TBT 180 DSN 4T
kg/h
kW1000 1500 2000 2500 3000 3500 4000
50 100 150 200 250 300 350
0
5
10
15
20
25
30
mbar
0002
3702
31-T
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEE
4) Equipped with automatic device for air closing.Net calorific value of heavy oil: Hi = 40,19 MJ/kg = 9600 kcal/kg.
Line filter - Flex hoses - Nozzles - Boiler coupling kit
Heavy oil burner accessories
Part no. DescriptionKit for heavy oil up to 20°E at 50°C98000302 Kit for BT 180 98000303 Kit for BT 25098000304 Kit for BT 300-350Kit for heavy oil with low sulphur content and max visco-sity of 15°E at 50°C98000307 Kit for BT 18098000308 Kit for BT 25098000309 Kit for BT 300-350
OptionalsDescriptionSteam pre-heater
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 50°C
725 ÷ 2009 BT 180 DSN 4T 2086010 7 3N AC 50Hz 400V 3 915 650 1645 200 ÷ 535 220 1730 x 1030 x 880 240 4)
937 ÷ 3170 BT 250 DSN 4T 2101010 7 3N AC 50Hz 400V 7,5 945 780 1665 235 ÷ 590 220 1730 x 1030 x 880 280 4)
1220 ÷ 3460 BT 300 DSN 4T 2131010 7 3N AC 50Hz 400V 7,5 1135 840 1900 245 ÷ 605 275 2030 x 1210 x 990 350 4)
1284 ÷ 3907 BT 350 DSN 4T 2121010 7 3N AC 50Hz 400V 9 1205 960 1960 350 ÷ 560 275 2260 x 1520 x 1200 420 4)
725 ÷ 2009 BT 180 DSN 4T 20865410 7 3N AC 60Hz 400V 3,5 915 650 1645 200 ÷ 535 220 1730 x 1030 x 880 240 4)
937 ÷ 3170 BT 250 DSN 4T 21015410 7 3N AC 60Hz 400V 9 945 780 1665 235 ÷ 590 220 1730 x 1030 x 880 280 4)
1220 ÷ 3460 BT 300 DSN 4T 21315410 7 3N AC 60Hz 400V 9 1135 840 1900 245 ÷ 605 275 2030 x 1210 x 990 350 4)
1284 ÷ 3907 BT 350 DSN 4T 21215410 7 3N AC 60Hz 400V 11 1205 960 1960 350 ÷ 560 275 2260 x 1520 x 1200 420 4)
Frequency 50 Hz
Frequency 60 Hz
Heavy oil
5353
Series BT...DSN 4T from 725 to 3907 kWTwo-stage heavy oil burners with hinge
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEE
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Heavy oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance made easy because the burner can
be opened without having to remove it from theboiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• When using heavy oil of viscosity up to 20°E at50°C, add the kit (to be ordered separately)consisting of: resistors for the pump, the atomisationunit and first and second stage solenoid.
• When using low sulphur heavy oil, add the kit (to beordered separately) consisting of: specific line filter,stainless steel flexible hoses and resistors forpump,atomisation unit and first and second stagesolenoid.
• On request it is possible to add to the burner asupplementary heavy oil pre-heater using steam,which means the fuel can be heated by the steamfrom the boiler to provide an energy saving.
• Equipped with one insulating seal for boilerfastening, 2 flexible hoses, one line filter and 3
nozzles (2 nozzles for BT 180).• On request: steam pre-heater.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Fixed boiler attachment flange with hinge to aid
removal of atomising unit and disc.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan and pump.• Gear pump with pressure regulator and fuel stop-cock
valves.• Atomisation unit with nozzle-closing pin.• Electrical fuel preheater comprising antigas valve,
filter, thermometer, regulation thermostats andminimum safety device.
• Automatic control and command equipment for theburner compliant with European standard EN230.
• Flame detection by photoresistance.• Control panel including stop/go switch, 1st/2nd
stage selector, operation and block indicators,heating element operation light.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
Olio C.
0002
9217
10-T
BT 250 DSN 4T BT 300 DSN 4T BT 350 DSN 4TBT 180 DSN 4T
kg/h
kW1000 1500 2000 2500 3000 3500 4000
50 100 150 200 250 300 350
0
5
10
15
20
25
30
mbar
0002
3702
21-T-
EXP
4) Equipped with automatic device for air closing.Net calorific value of heavy oil: Hi = 40,19 MJ/kg = 9600 kcal/kg.
Line filter - Flex hoses - Nozzles - Boiler coupling kit
Heavy oil burner accessories
Part no. DescriptionKit for heavy oil up to 20°E at 50°C98000302 Kit for BT 180
98000303 Kit for BT 25098000304 Kit for BT 300-350Kit for heavy oil with low sulphur content and max visco-sity of 15°E at 50°C98000307 Kit for BT 18098000308 Kit for BT 25098000309 Kit for BT 300-350
OptionalsDescriptionSteam pre-heater
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 50°C
Frequency 50 Hz
Frequency 60 Hz
725 ÷ 2009 BT 180 DSN 4T Hinged 2086011 7 3N AC 50Hz 400V 3 755 900 1210 280 225 1360 x 910 x 1140 240 4)
937 ÷ 3170 BT 250 DSN 4T Hinged 2101011 7 3N AC 50Hz 400V 7,5 945 1030 1235 295 225 1400 x 1160 x 1350 280 4)
1220 ÷ 3460 BT 300 DSN 4T Hinged 2131011 7 3N AC 50Hz 400V 7,5 945 1170 1530 420 280 1700 x 1460 x 1450 350 4)
1284 ÷ 3907 BT 350 DSN 4T Hinged 2121011 7 3N AC 50Hz 400V 9 1085 1225 1530 420 280 1700 x 1460 x 1450 420 4)
725 ÷ 2009 BT 180 DSN 4T Hinged 20865411 7 3N AC 60Hz 400V 3,5 755 900 1210 280 225 1360 x 910 x 1140 240 4)
937 ÷ 3170 BT 250 DSN 4T Hinged 21015411 7 3N AC 60Hz 400V 9 945 1030 1235 295 225 1400 x 1160 x 1350 280 4)
1220 ÷ 3460 BT 300 DSN 4T Hinged 21315411 7 3N AC 60Hz 400V 9 945 1170 1530 420 280 1700 x 1460 x 1450 350 4)
1284 ÷ 3907 BT 350 DSN 4T Hinged 21215411 7 3N AC 60Hz 400V 11 1085 1225 1530 420 280 1700 x 1460 x 1450 420 4)
Heavy oil
5454
0002
3702
31-T
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Heavy oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without havingto remove the burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• On request it is possible to integrate the BT 120with a supplementary steam-operated heavy oilpre-heater: during routine operation this allowsthe fuel to be heated with the steam from theboiler, thus reducing electricity consumption.
• Equipped with one flange and one insulatingseal for boiler fastening, 2 flexible hoses andone self-cleaning line filter with resistance;nozzle not included, to be ordered separelydepending on the required flow.
• On request: steam pre-heater (only BT 120).
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.
• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• A three-phase electric motor to run fan and
another to run the pump.• Air pressure switch to ensure the presence of
combustion air.• Gear pump with pressure regulator and fuel stop-
cock valves.• Heating resistor for the pump, regulator valve and
the atomisation unit.• Atomisation unit with magnet to control the
outlet/nozzle return pins.• Electrical fuel preheater comprising antigas valve,
self-cleaning filter, thermometer, minimum andregulation thermostat.
• Automatic control and command equipment for theburner compliant with European standard EN230.
• Flame detection by photoresistance.• Control panel including stop/go switch, 1st/2nd
stage selector, operation and block indicators,heating element operation light.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
Series BT...DSNM-D from 446 to 1451 kWTwo-stage heavy oil burners
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEE
4) Equipped with automatic device for air closing.Net calorific value of heavy oil: Hi = 40,19 MJ/kg = 9600 kcal/kg.
Self-cleaning line filter with thermostat-operated element - Flex hoses -Boiler coupling kit
Heavy oil burner accessories
OptionalsDescriptionSteam pre-heater for BT 120
Notes
BT 120 DSNM-DBT 100 DSNM-D
600
14
13
12
11
10
130120110100
15001400130012001100
BT 75 DSNM-D
9080706050403020
1000900800700600500400300200100kg/h Olio C.
mbar
9
8
7
6
5
0
4
3
2
1
10
kW
0002
9223
00/1
-T
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 50°C
446 ÷ 837 BT 75 DSNM-D 2500010 50 3N AC 50Hz 400V 1,1+0,55 860 545 1385 170 ÷ 430 160 1730 x 1030 x 880 140 4)
558 ÷ 1116 BT 100 DSNM-D 2503010 50 3N AC 50Hz 400V 1,5+0,55 860 560 1320 210 ÷ 400 195 1730 x 1030 x 880 145 4)
669 ÷ 1451 BT 120 DSNM-D 2505010 50 3N AC 50Hz 400V 2,2+1,1 910 610 1400 185 ÷ 450 195 1730 x 1030 x 880 200 4)
446 ÷ 837 BT 75 DSNM-D 25005410 50 3N AC 60Hz 400V 1,5+0,65 860 545 1385 170 ÷ 430 160 1730 x 1030 x 880 140 4)
558 ÷ 1116 BT 100 DSNM-D 25035410 50 3N AC 60Hz 400V 2,6+0,65 860 560 1320 210 ÷ 400 195 1730 x 1030 x 880 145 4)
669 ÷ 1451 BT 120 DSNM-D 25055410 50 3N AC 60Hz 400V 3,5+1,3 910 610 1400 185 ÷ 450 195 1730 x 1030 x 880 200 4)
Frequency 50 Hz
Frequency 60 Hz
Heavy oil
To complete the burnerNozzle with 1-3 ratio (see page 167).
5555
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Heavy oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion chamber.• High pressure mechanical atomisation of fuel
using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without havingto remove the burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• On request it is possible to add to the burner asupplementary heavy oil pre-heater using steam,which means the fuel can be heated by the steamfrom the boiler to provide an energy saving.
• Equipped with one flange and one insulating sealfor boiler fastening, 2 flexible hoses and one self-cleaning line filter with resistance; nozzle notincluded, to be separely ordered depending onthe required flow.
• On request: steam pre-heater.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.
• Combustion air intake with air flow adjustmentdevice.
• Sliding boiler coupling flange to adapt the headprotrusion to the various types of boilers.
• Adjustable blast-pipe with stainless steel nozzleand deflector disk in steel.
• A three-phase electric motor to run fan andanother to run the pump.
• Air pressure switch to ensure the presence ofcombustion air.
• Gear pump with pressure regulator and fuel stop-cock valves.
• Heating resistor for the pump, regulator valve andthe atomisation unit.
• Atomisation unit with magnet to control theoutlet/nozzle return pins.
• Electrical fuel preheater comprising antigas valve,self-cleaning filter, thermometer, regulation,minimum and safety thermostats.
• Automatic control and command equipment for theburner compliant with European standard EN230.
• Flame detection by photoresistance.• Control panel including stop/go switch, 1st/2nd
stage selector, operation and block indicators,heating element operation light.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
Series BT...DSNM-D from 725 to 3907 kWTwo-stage heavy oil burners
Olio C.
0002
9217
10/1
-T
BT 250 DSNM-D BT 300 DSNM-D BT 350 DSNM-DBT 180 DSNM-D
kg/hkW
1000 1500 2000 2500 3000 3500 4000
50 100 150 200 250 300 350
0
5
10
15
20
25
30
mbar
0002
3702
31-T
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEE
4) Equipped with automatic device for air closing.Net calorific value of heavy oil: Hi = 40,19 MJ/kg = 9600 kcal/kg.
Self-cleaning line filter with thermostat-operated element - Flex hoses -Boiler coupling kit
Heavy oil burner accessories
OptionalsDescriptionSteam pre-heater
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 50°C
725 ÷ 2009 BT 180 DSNM-D 2507010 50 3N AC 50Hz 400V 3+1,1 915 650 1645 200 ÷ 535 220 1730 x 1030 x 880 265 4)
937 ÷ 3170 BT 250 DSNM-D 2515010 50 3N AC 50Hz 400V 7,5+1,1 1025 780 1665 235 ÷ 590 220 2030 x 1210 x 990 300 4)
1220 ÷ 3460 BT 300 DSNM-D 2520010 50 3N AC 50Hz 400V 7,5+2,2 1135 840 1900 245 ÷ 605 275 2260 x 1520 x 1200 350 4)
1284 ÷ 3907 BT 350 DSNM-D 2525010 50 3N AC 50Hz 400V 9+2,2 1220 960 1960 350 ÷ 560 275 2260 x 1520 x 1200 440 4)
725 ÷ 2009 BT 180 DSNM-D 25075410 50 3N AC 60Hz 400V 3,5+1,3 915 650 1645 200 ÷ 535 220 1730 x 1030 x 880 265 4)
937 ÷ 3170 BT 250 DSNM-D 25155410 50 3N AC 60Hz 400V 9+1,3 1025 780 1665 235 ÷ 590 220 2030 x 1210 x 990 300 4)
1220 ÷ 3460 BT 300 DSNM-D 25205410 50 3N AC 60Hz 400V 9+2,6 1135 840 1900 245 ÷ 605 275 2260 x 1520 x 1200 350 4)
1284 ÷ 3907 BT 350 DSNM-D 25255410 50 3N AC 60Hz 400V 11+2,6 1220 960 1960 350 ÷ 560 275 2260 x 1520 x 1200 440 4)
Frequency 50 Hz
Frequency 60 Hz
Heavy oil
To complete the burnerNozzle with 1-3 ratio (see page 167).
5656
0002
3702
31-T
Series BT...DSPN from 446 to 1451 kWProgressive/modulating two-stage heavy oil burners
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEE
4) Equipped with automatic device for air closing.Net calorific value of heavy oil: Hi = 40,19 MJ/kg = 9600 kcal/kg.
Line filter - Flex hoses - Boiler coupling kit
Heavy oil burner accessories
Part no.Kit for heavy oil up to 50°E at 50°C98000315Kit for heavy oil with low sulphur content and max visco-sity of 15°E at 50°C98000318
OptionalsDescriptionSteam pre-heater for BT 120
Notes
BT 120 DSPNBT 100 DSPN
600
14
13
12
11
10
130120110100
15001400130012001100
BT 75 DSPN
9080706050403020
1000900800700600500400300200100kg/h Olio C.
mbar
9
8
7
6
5
0
4
3
2
1
10
kW
0002
9223
00/2
-T
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 50°C
446 ÷ 837 BT 75 DSPN 2610010 7 3N AC 50Hz 400V 1,1+0,55 860 635 1385 195 ÷ 515 160 1730 x 1030 x 880 147 4)
558 ÷ 1116 BT 100 DSPN 2615010 7 3N AC 50Hz 400V 1,5+0,55 860 635 1320 210 ÷ 400 195 1730 x 1030 x 880 150 4)
669 ÷ 1451 BT 120 DSPN 2620010 7 3N AC 50Hz 400V 2,2+1,1 910 685 1400 185 ÷ 450 195 1730 x 1030 x 880 224 4)
446 ÷ 837 BT 75 DSPN 26105410 7 3N AC 60Hz 400V 1,5+0,65 860 635 1385 195 ÷ 515 160 1730 x 1030 x 880 147 4)
558 ÷ 1116 BT 100 DSPN 26155410 7 3N AC 60Hz 400V 2,6+0,65 860 635 1320 210 ÷ 400 195 1730 x 1030 x 880 150 4)
669 ÷ 1451 BT 120 DSPN 26205410 7 3N AC 60Hz 400V 3,5+1,3 910 685 1400 185 ÷ 450 195 1730 x 1030 x 880 224 4)
Frequency 50 Hz
Frequency 60 Hz
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Heavy oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the controlpanel (to be ordered separately with the modulation kit).
• Ability to operate with any type of combustion chamber.• High pressure mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without having toremove the burner from the boiler.
• Minimum and maximum air flow regulation for first andsecond stage by means of electric servomotor with pauseclosure of gate to prevent any heat dispersion to flue.
• When using heavy oil of viscosity up to 50°E at 50°C,add the kit (to be ordered separately) consisting of: self-cleaning line filter with resistor and thermostat andresistors for pump and pressure regulator valve.
• When using low sulphur heavy oil, add the kit (toorder separately) consisting of: specific line filter,stainless steel flexible hoses and resistors for pumpand pressure regulator valve.
• On request it is possible to integrate the BT 120 witha supplementary steam-operated heavy oil pre-heater: during routine operation this allows the fuelto be heated with the steam from the boiler, thusreducing electricity consumption.
• Equipped with one flange and one insulating seal forboiler fastening, 2 flexible hoses and one line filter;nozzle not included, to be ordered separately
depending on the required flow.• On request: steam pre-heater (only BT 120).
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head protrusion
to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle and
deflector disk in steel.• A three-phase electric motor to run fan and another to
run the pump.• Air pressure switch to ensure the presence of combustion air.• Electric servomotor with mechanical cam for simultaneous
regulation of combustion air and fuel.• Gear pump with pressure regulator.• Atomisation unit with magnet to control the outlet/nozzle
return pins.• Electrical fuel preheater comprising antigas valve,
self-cleaning filter, thermometer, regulation, minimumand safety thermostats.
• Automatic control and command equipment for the burnercompliant with European standard EN230.
• Flame detection by photoresistance.• Control panel including stop/go switch, operation and
block indicators, heating element operation light.• Terminal block for the electrical and thermostatic
connections to the burner and to control the second stageof working or for the connection of the electronic outputregolator.
• Electrical protection rating IP40.
Heavy oil
To complete the burner: Nozzle with 1-3 ratio (see page 167).Modulating mode: Complete the burner with the automatic RWF40regulator and the modulation kit (see page 166).
5757
Series BT...DSPN from 725 to 3907 kWProgressive/modulating two-stage heavy oil burners
Olio C.
00
02
92
17
10
/2-T
BT 250 DSPN BT 300 DSPN BT 350 DSPNBT 180 DSPN
kg/hkW
1000 1500 2000 2500 3000 3500 4000
50 100 150 200 250 300 350
0
5
10
15
20
25
30
mbar
0002
3702
31-T
4) Equipped with automatic device for air closing.Net calorific value of heavy oil: Hi = 40,19 MJ/kg = 9600 kcal/kg.
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEE
Line filter - Flex hoses - Boiler coupling kit
Heavy oil burner accessories
Part no. DescriptionKit for heavy oil up to 50°E at 50°C98000315 Kit for BT 180-25098000316 Kit for BT 300-350Kit for heavy oil with low sulphur content and maxviscosity of 15°E at 50°C98000318 Kit for BT 180-25098000319 Kit for BT 300-350
OptionalsDescriptionSteam pre-heater
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 50°C
725 ÷ 2009 BT 180 DSPN 2625010 7 3N AC 50Hz 400V 3+1,1 915 680 1645 200 ÷ 535 220 1730 x 1030 x 880 274 4)
937 ÷ 3170 BT 250 DSPN 2630010 7 3N AC 50Hz 400V 7,5+1,1 1025 780 1665 235 ÷ 590 220 2030 x 1210 x 990 314 4)
1220 ÷ 3460 BT 300 DSPN 2635010 7 3N AC 50Hz 400V 7,5+2,2 1135 840 1900 245 ÷ 605 275 2260 x 1520 x 1200 513 4)
1284 ÷ 3907 BT 350 DSPN 2640010 7 3N AC 50Hz 400V 9+2,2 1220 960 1960 350 ÷ 560 275 2260 x 1520 x 1200 545 4)
725 ÷ 2009 BT 180 DSPN 26255410 7 3N AC 60Hz 400V 3,5+1,3 915 680 1645 200 ÷ 535 220 1730 x 1030 x 880 274 4)
937 ÷ 3170 BT 250 DSPN 26305410 7 3N AC 60Hz 400V 9+1,3 1025 780 1665 235 ÷ 590 220 2030 x 1210 x 990 314 4)
1220 ÷ 3460 BT 300 DSPN 26355410 7 3N AC 60Hz 400V 9+2,6 1135 840 1900 245 ÷ 605 275 2260 x 1520 x 1200 513 4)
1284 ÷ 3907 BT 350 DSPN 26405410 7 3N AC 60Hz 400V 11+2,6 1220 960 1960 350 ÷ 560 275 2260 x 1520 x 1200 545 4)
Frequency 50 Hz
Frequency 60 Hz
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Heavy oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the controlpanel (to be ordered separately with the modulation kit).
• Ability to operate with any type of combustion chamber.• High pressure mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without having toremove the burner from the boiler.
• Minimum and maximum air flow regulation for firstand second stage by means of electric servomotorwith pause closure of gate to prevent any heatdispersion to flue.
• When using heavy oil of viscosity up to 50°E at 50°C,add the kit (to be ordered separately) consisting of: self-cleaning line filter with resistor and thermostat andresistors for pump and pressure regulator valve.
• When using low sulphur heavy oil, add the kit (to beorder separately) consisting of: specific line filter,stainless steel flexible hoses and resistors for pumpand pressure regulator valve.
• On request it is possible to add to the burner asupplementary heavy oil pre-heater using steam,which means the fuel can be heated by the steamfrom the boiler to provide an energy saving.
• Equipped with one flange and one insulating seal forboiler fastening, 2 flexible hoses and one line filter;nozzle not included, to be ordered separately
depending on the required flow.• On request: steam pre-heater.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head protrusion
to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle and
deflector disk in steel.• A three-phase electric motor to run fan and another to
run the pump.• Air pressure switch to ensure the presence of combustion air.• Electric servomotor with mechanical cam for simultaneous
regulation of combustion air and fuel.• Gear pump with pressure regulator.• Atomisation unit with magnet to control the outlet/nozzle
return pins.• Electrical fuel preheater comprising antigas valve,
self-cleaning filter, thermometer, regulation, minimumand safety thermostats.
• Automatic control and command equipment for the burnercompliant with European standard EN230.
• Flame detection by photoresistance.• Control panel including stop/go switch, 1st/2nd
stage selector, operation and block indicators,heating element operation light.
• Terminal block for the electrical and thermostatic connectionsto the burner and to control the second stage of working orfor the connection of the electronic output regolator.
• Electrical protection rating IP40.
Heavy oil
To complete the burner: Nozzle with 1-3 ratio (see page 167).Modulating mode: Complete the burner with the automatic RWF40regulator and the modulation kit (see page 166).
5858
0002
9212
82/3
-T
GI 510 DSPN-DGI 420 DSPN-DGI 350 DSPN-D
30
1
0
0
25
8
20
15
mbar
10
5
kWx1000765432
kg/h Olio C.600500400300200100
Series GI...DSPN-D from 1581 to 6500 kWProgressive/modulating two-stage heavy oil burners
0002
3702
31/2
-T
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEE
4) Equipped with automatic device for air closing.Net calorific value of heavy oil: Hi = 40,19 MJ/kg = 9600 kcal/kg.
Self-cleaning line filter with thermostat-operated element - Flex hoses -Boiler coupling kit
Heavy oil burner accessories
OptionalsDescriptionSteam pre-heater
Notes
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 50°C
1581 ÷ 4743 GI 350 DSPN-D 6533010 50 3N AC 50Hz 400V 15+2,2 1345 1010 1900 275 ÷ 500 275 2260 x 1520 x 1200 578 4)
1840 ÷ 5522 GI 420 DSPN-D 6538010 50 3N AC 50Hz 400V 18,5+3 1345 1040 2030 275 ÷ 560 355 2260 x 1520 x 1200 672 4)
2430 ÷ 6500 GI 510 DSPN-D 6543010 50 3N AC 50Hz 400V 18,5+3 1345 1040 2030 275 ÷ 560 355 2260 x 1520 x 1200 704 4)
1581 ÷ 4743 GI 350 DSPN-D 65335410 50 3N AC 60Hz 400V 11+2,6 1345 1010 1900 275 ÷ 500 275 2260 x 1520 x 1200 578 4)
1840 ÷ 5522 GI 420 DSPN-D 65385410 50 3N AC 60Hz 400V 13+3,5 1345 1040 2030 275 ÷ 560 355 2260 x 1520 x 1200 672 4)
2430 ÷ 6500 GI 510 DSPN-D 65435410 50 3N AC 60Hz 400V 22+3,5 1345 1040 2030 275 ÷ 560 355 2260 x 1520 x 1200 704 4)
Frequency 50 Hz
Frequency 60 Hz
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Heavy oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means
of automatic RWF40 regulator mounted on thecontrol panel (to be ordered separately with themodulation kit).
• Ability to operate with any type of combustion chamber.• High pressure mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without having toremove the burner from the boiler.
• Minimum and maximum air flow regulation for firstand second stage by means of electric servomotorwith pause closure of gate to prevent any heatdispersion to flue.
• On request it is possible to add to the burner asupplementary heavy oil pre-heater using steam,which means the fuel can be heated by the steamfrom the boiler to provide an energy saving.
• Equipped with one flange and one insulating seal for boilerfastening, 2 flexible hoses and one self-cleaning line filterwith resistance; nozzle not included, to be separelyordered depending on the required flow.
• On request: steam pre-heater.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.
• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle and
deflector disk in steel.• A three-phase electric motor to run fan and another to
run the pump.• Air pressure switch to ensure the presence of combustion
air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• Gear pump with pressure regulator.• Heating resistor for the pump, regulator valve and the
atomisation unit.• Atomisation unit with magnet to control the outlet/nozzle
return pins.• Electrical fuel preheater comprising antigas valve,
self-cleaning filter, thermometer, regulation, minimumand safety thermostats.
• Automatic control and command equipment for theburner compliant with European standard EN230.
• Flame detection by photoresistance.• Control panel including stop/go switch, operation
and block indicators, heating element operationlight.
• Terminal block for the electrical and thermostaticconnections to the burner and to control the secondstage of working or for the connection of the electronicoutput regolator.
• Electrical protection rating IP40.
Heavy oil
To complete the burnerNozzle with 1-3 ratio (see page 167).Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
5959
GI 1000 DSPN-D30
1110
25
1098
0002
9212
81/4
-T
20
15
mbar
10
5
kWx1000765432
0 900800700600500400300200100kg/h Olio c.
GI 1000 DSPN-D from 2500 to 10500 kWProgressive/modulating two-stage heavy oil burners
D
A
C
B
0002
2703
32/6
-TConform to:
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
4) Equipped with automatic device for air closing.Net calorific value of heavy oil: Hi = 40,19 MJ/kg = 9600 kcal/kg.
Self-cleaning line filter with thermostat-operated element - Flex hoses -Boiler coupling kit
Heavy oil burner accessories
Notes
OptionalsDescriptionSteam pre-heater
Amm
Bmm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 50°C
2500 ÷ 10500 GI 1000 DSPN-D 6553010 50 3N AC 50Hz 400V 22+4 1465 1257 1710 430 490 2600 x 1710 x 1500 1040 4)
Frequency 50 Hz
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Heavy oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the control panel(to be ordered separately with the modulation kit).
• Ability to operate with any type of combustion chamber.• High pressure mechanical atomisation of fuel using
nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the
atomisation unit can be removed without having toremove the burner from the boiler.
• Minimum and maximum air flow regulation for first andsecond stage by means of electric servomotor with pauseclosure of gate to prevent any heat dispersion to flue.
• On request it is possible to add to the burner asupplementary heavy oil pre-heater using steam,which means the fuel can be heated by the steamfrom the boiler to provide an energy saving.
• Equipped with one insulating seal for boiler fastening, 2flexible hoses and one self-cleaning line filter withresistance; nozzle not included, to be separely ordereddepending on the required flow.
• On request: steam pre-heater.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Steel fan part
• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Boiler coupling flange with hinge to facilitate dismantling
of the atomising unit and deflector disk.• Adjustable blast-pipe with stainless steel nozzle and
deflector disk in steel.• A three-phase electric motor to run fan and another
to run the pump.• Air pressure switch to ensure the presence of combustion air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• Gear pump with pressure regulator.• Heating resistor for the pump, regulator valve and
the atomisation unit.• Atomisation unit with magnet to control the
outlet/nozzle return pins.• Two electrical preheaters in series and mounted on a
frame comprising antigas valve, self-cleaning filter,thermometer, electronic temperature regulation andsafety thermostats.
• Automatic control and command equipment for theburner compliant with European standard EN230.
• Flame detection by UV photo-electric cell.• On-board terminal box and separate control
panel comprising stop/go switch,automatic/manual and minimum/maximumselectors, operation and block indicators.
• Terminal block for the electrical and thermostatic connectionsto the burner and to control the second stage of working orfor the connection of the electronic output regolator.
• Electrical protection rating IP40.
Heavy oil
To complete the burnerNozzle with 1-5 ratio (see page 167).Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
6060
BTG 3 from 16,6 to 42,7 kWSingle-stage gas burners
BTG 3 BTG 3.6 BTG 6 BTG 11
0002922222-T
10 100 110
0.5
1
1
1.5
1.5 2.5 3.5
20
2
2
2.5
30
3
43
40 50 60 70 80 90
111
0.5
0
1098765432
mbar
kWmn3/h
mn3/h
Metano
G.P.L.
A
D
C
ØF
B5B1
1° 30'
0002
4705
81-T
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Single stage operation (on/off).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Manual air flow adjustment.• Possibility to chose gas train with valve tightness
control.• Equipped with one 7 pole connector, one flange
and one insulating seal for boiler fastening.• On request: longer blast tube.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air inlet with device to adjust the air
flow; automatically closing air gate.• Fixed boiler coupling flange.• Adjustable combustion head complete with steel
blast tube and deflector disk.• Monophase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by ionisation electrode.• 7 pole outlet for burner electrical and thermostat
connections.• Prepared for microamperometer connection with
ionisation cable.• Electrical protection rating IP40.• Sound-proof plastic protective cover.
Boiler coupling kit - 7 pin plug
Gas burner accessories
OptionalsDescription300 mm long combustion head
0085
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
16,6 ÷ 42,7 BTG 3 17000010 1N AC 50Hz 230V 0,09 250 170 48 330 90 90 400 x 280 x 280 9 1)
16,6 ÷ 42,7 BTG 3 17000010 1N AC 60Hz 230V 0,09 250 170 48 330 90 90 400 x 280 x 280 9 1)
Frequency 50 Hz
Frequency 60 Hz
1) Equipped with air closure device.5) Valve tightness control not required by EN676.CTV)Gas train with Valve Tightness Control.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Notes
Natural gas
LPG
6161
CE30 19990338 Included — — M2
BTG 3 LPGCTV 30 19990338 Included — 98000100 M2 5)
EXP30 19990143 — — — ME1
CTV 30 19990338 Included — 98000100 M2
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type
BTG 3 from 16,6 to 42,7 kWGas train
CE 1A200 19990338 Included — — M2
CTV 200 19990338 Included — 98000100 M2 5)
BTG 3NATURAL
1A200 19990338 Included — — M2
GASEXP CTV 200 19990338 Included — 98000100 M2
1J 40 19990143 — — — ME1
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BTG 3 metanoCE
ediz.03/2003
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
10 15 20 25 30 35 40 45 50
PORTATA kW
PR
ES
SIO
NE
m
bar
1A
Perdite di carico(testa di combustione + rampa gas)
BTG 3 metanoEXP
ediz.03/2003
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
10 15 20 25 30 35 40 45 50
PORTATA kW
PR
ES
SIO
NE
m
bar
1A
1J
Burnermodel Pic.
Gas train
Part no.
Gas train
Part no.
NotesBurner/gas train
adapterPart no.
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.
Regulatorwith incorporated filter
Part no.
P.Max**mbar
Curveon
graphExecution
Execution
VersionGastype
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Head loss (combustion head + gastrain + pressure regulator)
PRES
SURE
THERMAL OUTPUT
Natural gas Head loss (combustion head + gas train)
PRES
SURE
THERMAL OUTPUT
Natural gas
6262
Series BTG... from 16,3 to 99 kWSingle-stage gas burners
BTG 3 BTG 3.6 BTG 6 BTG 11
0002922222-T
10 100 110
0.5
1
1
1.5
1.5 2.5 3.5
20
2
2
2.5
30
3
43
40 50 60 70 80 90
111
0.5
0
1098765432
mbar
kWmn3/h
mn3/h
Metano
G.P.L.
A
D
C
ØF
B5B1
1° 30'
0002
4705
81-T
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Single stage operation (on/off).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Manual air flow adjustment.• Possibility to chose gas train with valve tightness
control.• Equipped with one 7 pole connector, one flange
and one insulating seal for boiler fastening.• On request: longer blast tube.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air inlet with device to adjust the air
flow; automatically closing air gate.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable combustion head complete with blast
tube (stainless steel for BTG 11) and steeldeflector disk.
• Monophase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by ionisation electrode.• 7 pole outlet for burner electrical and thermostat
connections.• Prepared for microamperometer connection with
ionisation cable.• Electrical protection rating IP40.• Sound-proof plastic protective cover.
1) Equipped with air closure device.5) Valve tightness control not required by EN676.CTV)Gas train with Valve Tightness Control.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Boiler coupling kit - 7 pin plug
Gas burner accessories
OptionalsDescription300 mm long combustion head
Notes
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
16,3 ÷ 41,9 BTG 3,6 17020010 1N AC 50Hz 230V 0,11 245 218,5 53 410 50 ÷ 105 90 500 x 300 x 320 12 1)
30,6 ÷ 56,3 BTG 6 17040010 1N AC 50Hz 230V 0,11 245 218,5 53 410 50 ÷ 105 90 500 x 300 x 320 12 1)
48,8 ÷ 99 BTG 11 17060010 1N AC 50Hz 230V 0,11 245 218,5 53 475 90 ÷ 150 90 540 x 300 x 320 12 1)
16,3 ÷ 41,9 BTG 3,6 17020010 1N AC 60Hz 230V 0,11 245 218,5 53 410 50 ÷ 105 90 500 x 300 x 320 12 1)
30,6 ÷ 56,3 BTG 6 17040010 1N AC 60Hz 230V 0,11 245 218,5 53 410 50 ÷ 105 90 500 x 300 x 320 12 1)
48,8 ÷ 99 BTG 11 17060010 1N AC 60Hz 230V 0,11 245 218,5 53 475 90 ÷ 150 90 540 x 300 x 320 12 1)
0085
Frequency 50 Hz
Frequency 60 Hz
Natural gas
LPG
6363
BTG 3,6 from 16,3 to 41,9 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BTG 3,6 metanoCE
ediz.04/2003
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0
5,5
6,0
6,5
7,0
7,5
8,0
8,5
9,0
9,5
10,0
10,5
10 15 20 25 30 35 40 45 50
PORTATA kW
PR
ES
SIO
NE
m
bar
2A
Perdite di carico(testa di combustione + rampa gas)
BTG 3,6 metanoEXP
ediz.04/2003
0,0
0,5
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0
5,5
6,0
6,5
7,0
7,5
8,0
8,5
9,0
9,5
10,0
10,5
10 15 20 25 30 35 40 45 50
PORTATA kW
PR
ES
SIO
NE
m
bar
2A
2J
CE30 19990338 Included 96000001 — M2
BTG 3,6 LPGCTV 30 19990338 Included 96000001 98000100 M2 5)
EXP30 19990235 — — — ME1
CTV 30 19990338 Included 96000001 98000100 M2
CE 2A200 19990338 Included 96000001 — M2
CTV 200 19990338 Included 96000001 98000100 M2 5)
BTG 3,6NATURAL
2A200 19990338 Included 96000001 — M2
GASEXP CTV 200 19990338 Included 96000001 98000100 M2
2J 40 19990235 — — — ME1
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type
Burnermodel Pic.
Gas train
Part no.
Gas train
Part no.
NotesBurner/gas train
adapterPart no.
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.
Regulatorwith incorporated filter
Part no.
P.Max**mbar
Curveon
graphExecution
Execution
VersionGastype
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas Head loss (combustion head + gas train)
Pres
sure
Thermal output
Natural gas
6464
BTG 6 from 30,6 to 56,3 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BTG 6 metanoCE
ediz.04/2003
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
25 30 35 40 45 50 55 60 65
PORTATA kW
PR
ES
SIO
NE
m
bar
3A
3B
Perdite di carico(testa di combustione + rampa gas)
BTG 6 metanoEXP
ediz.04/2003
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
25 30 35 40 45 50 55 60 65
PORTATA kW
PR
ES
SIO
NE
m
bar
3A
3J
3B
CE30 19990338 Included 96000001 — M2
BTG 6 LPGCTV 30 19990338 Included 96000001 98000100 M2 5)
EXP30 19990235 — — — ME1
CTV 30 19990338 Included 96000001 98000100 M2
3A200 19990338 Included 96000001 — M2
CECTV 200 19990338 Included 96000001 98000100 M2 5)
3B360 19990002 Included — — M2
CTV 360 19990002 Included — 98000100 M2 5)
BTG 6NATURAL
3A200 19990338 Included 96000001 — M2
GASCTV 200 19990338 Included 96000001 98000100 M2
EXP3B
360 19990002 Included — — M2
CTV 360 19990002 Included — 98000100 M2
3J 40 19990235 — — — ME1
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type
Burnermodel Pic.
Gas train
Part no.
Gas train
Part no.
NotesBurner/gas train
adapterPart no.
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.
Regulatorwith incorporated filter
Part no.
P.Max**mbar
Curveon
graphExecution
Execution
VersionGastype
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gasHead loss (combustion head + gas train)
Pres
sure
Thermal output
Natural gas
6565
BTG 11 from 48,8 to 99 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BTG 11 metanoCE
ediz.03/2003
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
40 45 50 55 60 65 70 75 80 85 90 95 100 105
PORTATA kW
PR
ES
SIO
NE
m
bar
4A
4B
Perdite di carico(testa di combustione + rampa gas)
BTG 11 metanoEXP
ediz.03/2003
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
40 45 50 55 60 65 70 75 80 85 90 95 100 105
PORTATA kW
PR
ES
SIO
NE
m
bar
4A
4B
4J
CE30 19990338 Included 96000001 — M2
BTG 11 LPGCTV 30 19990338 Included 96000001 98000100 M2 5)
EXP30 19990235 — — — ME1
CTV 30 19990338 Included 96000001 98000100 M2
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type
Burnermodel Pic.
Gas train
Part no.
Gas train
Part no.
NotesBurner/gas train
adapterPart no.
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.
Regulatorwith incorporated filter
Part no.
P.Max**mbar
Curveon
graphExecution
Execution
VersionGastype
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gasHead loss (combustion head + gas train)
Pres
sure
Thermal output
Natural gas
4A200 19990338 Included 96000001 — M2
CECTV 200 19990338 Included 96000001 98000100 M2 5)
4B360 19990002 Included — — M2
NATURALCTV 360 19990002 Included — 98000100 M2 5)
BTG 11GAS 4A
200 19990338 Included 96000001 — M2
CTV 200 19990338 Included 96000001 98000100 M2
EXP4B
360 19990002 Included — — M2
CTV 360 19990002 Included — 98000100 M2
4J 40 19990235 — — — ME1
6666
Series BTG 20 from 60 to 205 kWSingle-stage gas burners with low pollutant emission
0
1
2
3
4
5
6
7
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 kW
mbar BTG 20
0002
4709
90-T
D
B5
B1 flF
CA
B
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Single stage operation (on/off).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe.• Burnt gas recycling blast-pipe able to achieve
very low pollutant emissions, particularly withregard to nitrous oxides (NOx).
• Maintenance facilitated by the fact that the mixingunit can be removed without having to removethe burner from the boiler.
• Manual air flow adjustment.• Possibility to chose gas train with valve tightness
control.• Equipped with one 7 pole connector, one flange
and one insulating seal for boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air inlet with device to adjust the air
flow; automatically closing air gate.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Monophase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by ionisation electrode.• 7 pole outlet for burner electrical and thermostat
connections.• Prepared for microamperometer connection with
ionisation cable.• Electrical protection rating IP40.• Sound-proof plastic protective cover.
1) Equipped with air closure device.5) Valve tightness control not required by EN676.CTV)Gas train with Valve Tightness Control.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Boiler coupling kit - 7 pin plug
Gas burner accessories
Notes
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
0085
Frequency 50 Hz
Frequency 60 Hz60 ÷ 205 BTG 20 17100010 1N AC 50Hz 230V 0,18 303 275 70 695 150 ÷ 300 114 710 x 370 x 410 18 1
60 ÷ 205 BTG 20 17100010 1N AC 60Hz 230V 0,18 303 275 70 695 150 ÷ 300 114 710 x 370 x 410 18 1)
LOWNOx
NEW
6767
Series BTG 20 from 60 to 205 kWGas train
Perdite di carico(testa di combustione + rampagas + regolatore di pressione)
BTG 20 metanoCE
ediz.03/2004
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
25 50 75 100 125 150 175 200 225
PORTATA kW
PR
ES
SIO
NE
m
bar
43A
43C
43B
Perdite di carico(testa di combustione + rampa gas)
BTG 20 metanoEXP
ediz.03/2004
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
50 75 100 125 150 175 200 225
PORTATA kW
PR
ES
SIO
NE
m
bar
43A
43C
43B
43J
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas Head loss (combustion head + gas train)
Pres
sure
Thermal output
Natural gas
BTG 2030 19990002 Included — — M2
LPG CE / EXPCTV 30 19990002 Included — 98000100 M2 5)
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
43A360 19990002 Included — — M2
CTV 360 19990002 Included — 98000100 M2 5)
CE 43B360 19990005 Included — — M2
CTV 360 19990005 Included — 98000100 M2 5)
43C360 19990008 Included 96000031 — M2
BTG 20NATURAL CTV 360 19990008 Included 96000031 98000100 M2 5)
GAS43A
360 19990002 Included — — M2
CTV 360 19990002 Included — 98000100 M2
43B360 19990005 Included — — M2
EXP CTV 360 19990005 Included — 98000100 M2
43C360 19990008 Included 96000031 — M2
CTV 360 19990008 Included 96000031 98000100 M2
43J 40 19990004 — — — ME1
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type
Burnermodel Pic.
Gas train
Part no.
Gas train
Part no.
NotesBurner/gas train
adapterPart no.
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.
Regulatorwith incorporated filter
Part no.
P.Max**mbar
Curveon
graphExecution
Execution
VersionGastype
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
6868
Series SPARKGAS 30/30W from 60 to 300 kWSingle-stage gas burners
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Single stage operation (on/off).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Manual air flow adjustment.• Possibility to chose gas train with valve tightness
control.• Equipped with one 7 pole connector, one flange
and one insulating seal for boiler fastening.• On request: longer blast tube, and device for air
gate closure during pause to avoid loss of heatup flue.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Monophase electric motor to run fan.• Device made from sound-absorbing material to
reduce fan noise.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by ionisation electrode.• Start/stop switch (except the W version).• 7 pole outlet for burner electrical and thermostat
connections.• Electrical protection rating IP40.• Sound-proof plastic protective cover (except the
W version).
G.P.L.
Metano
0002
9219
43-T
14
4036n
n
400360
3
3
mbar
2 6 10
10
8
6
4
12
320
32m /h
84
2802402001601208040
2824201612840
2
kW
m /h
SPARKGAS 30 SPARKGAS 35
3) Soundproof lid on burner air intake.5) Valve tightness control not required by EN676.CTV)Gas train with Valve Tightness Control.*) Minimum gas train inlet pressure needed to obtain maximum burner power with a
combustion chamber backpressure of zero.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
B1B5
Boiler coupling kit - 7 pin plug
Gas burner accessories
Accessories available on request
OptionalsDescription500 mm long combustion head Automatic Air Closure Device
Notes
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
Part no. Description97980054 Soundproof burner cover
0002
4705
81/1
-TB1B5
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
60 ÷ 300 SPARKGAS 30 W 15680010 1N AC 50Hz 230V 0,37 460 263 102 835 170 ÷ 300 135 1010 x 490 x 390 32 3)
60 ÷ 300 SPARKGAS 30 15700010 1N AC 50Hz 230V 0,37 490 275 102 860 170 ÷ 300 135 980 x 540 x 480 36 3)
60 ÷ 300 SPARKGAS 30 W 15685410 1N AC 60Hz 230V 0,37 460 263 102 835 170 ÷ 300 135 1010 x 490 x 390 32 3)
60 ÷ 300 SPARKGAS 30 15705410 1N AC 60Hz 230V 0,37 490 275 102 860 170 ÷ 300 135 980 x 540 x 480 36 3)
0085
Frequency 50 Hz
Frequency 60 Hz
Natural gas
LPG
6969
SPARKGAS 30/30W from 60 to 300 kWGas train
Perdite di carico(testa di combustione + rampagas + regolatore di pressione)
SPARKGAS 30/30W metanoCE
ediz.03/2003
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
25 50 75 100 125 150 175 200 225 250 275 300 325
PORTATA kW
PR
ES
SIO
NE
m
bar
6A
6C
6B
SPARKGAS 30 CE / EXP
30 19990005 Included 96000005 — M2
SPARKGAS 30WLPG
CTV 30 19990005 Included 96000005 98000100 M2 5)
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type
Burnermodel Pic.
Gas train
Part no.
Gas train
Part no.
NotesBurner/gas train
adapterPart no.
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.
Regulatorwith incorporated filter
Part no.
P.Max**mbar
Curveon
graphExecution
Execution
VersionGastype
6A360 19990005 Included 96000005 — M2
CTV 360 19990005 Included 96000005 98000100 M2 5)
CE 6B360 19990008 Included — — M2
CTV 360 19990008 Included — 98000100 M2 5)
6C360 19990166 Included — — M2
NATURALCTV 360 19990166 Included — 98000100 M2 5)
SPARKGAS 30
GAS 6A360 19990005 Included 96000005 — M2
SPARKGAS 30WCTV 360 19990005 Included 96000005 98000100 M2
6B360 19990008 Included — — M2
EXP CTV 360 19990008 Included — 98000100 M2
6C360 19990166 Included — — M2
CTV 360 19990166 Included — 98000100 M2
6J 40 19990134 — 96000006 — ME1
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gasHead loss(combustion head + gas train)
Pres
sure
Thermal output
Natural gas
7070
Series SPARKGAS 35/35W from 90 to 358 kWSingle-stage gas burners
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Single stage operation (on/off).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Manual air flow adjustment.• Possibility to chose gas train with valve tightness
control.• Equipped with one 7 pole connector, one flange
and one insulating seal for boiler fastening.• On request: longer blast tube, and device for air
gate closure during pause to avoid loss of heatup flue.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Monophase electric motor to run fan.• Device made from sound-absorbing material to
reduce fan noise.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by ionisation electrode.• Start/stop switch (except the W version).• 7 pole outlet for burner electrical and thermostat
connections.• Electrical protection rating IP40.• Sound-proof plastic protective cover (except the
W version).
3) Soundproof lid on burner air intake.5) Valve tightness control not required by EN676.CTV)Gas train with Valve Tightness Control.*) Minimum gas train inlet pressure needed to obtain maximum burner power with a
combustion chamber backpressure of zero.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
B1B5
Boiler coupling kit - 7 pin plug
Gas burner accessories
Accessories available on request
OptionalsDescription500 mm long combustion head Automatic Air Closure Device
Notes
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
Part no. Description97980054 Soundproof burner cover
0002
4705
81/1
-TB1B5
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
0085
Frequency 50 Hz
Frequency 60 Hz
90 ÷ 358 SPARKGAS 35 W 15740010 1N AC 50Hz 230V 0,37 475 263 102 925 130 ÷ 350 135 1010 x 490 x 390 32 3)
90 ÷ 358 SPARKGAS 35 15760010 1N AC 50Hz 230V 0,37 490 275 102 965 130 ÷ 350 135 1100 x 540 x 480 36 3)
90 ÷ 358 SPARKGAS 35 W 15745410 1N AC 60Hz 230V 0,37 475 263 102 925 130 ÷ 350 135 1010 x 490 x 390 32 3)
90 ÷ 358 SPARKGAS 35 15765410 1N AC 60Hz 230V 0,37 490 275 102 965 130 ÷ 350 135 1100 x 540 x 480 36 3)
G.P.L.
Metano
0002
9219
43-T
14
4036n
n
400360
3
3
mbar
2 6 10
10
8
6
4
12
320
32m /h
84
2802402001601208040
2824201612840
2
kW
m /h
SPARKGAS 30 SPARKGAS 35
Natural gas
LPG
7171
SPARKGAS 35/35W from 90 to 358 kWGas train
Perdite di carico(testa di combustione + rampagas + regolatore di pressione)
SPARKGAS 35/35W metanoCE / EXP
ediz.02/2004
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
50 75 100 125 150 175 200 225 250 275 300 325 350 375 400
PORTATA kW
PR
ES
SIO
NE
m
bar
7A
7C
7B
SPARKGAS 35 CE / EXP
30 19990005 Included 96000005 — M2
SPARKGAS 35WLPG
CTV 30 19990005 Included 96000005 98000100 M2 5)
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
7A360 19990005 Included 96000005 — M2
CTV 360 19990005 Included 96000005 98000100 M2 5)
SPARKGAS 35 NATURAL7B
360 19990008 Included — — M2
SPARKGAS 35W GASCE / EXP
CTV 360 19990008 Included — 98000100 M2 5)
7C360 19990166 Included — — M2
CTV 360 19990166 Included — 98000100 M2 5)
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type
Burnermodel Pic.
Gas train
Part no.
Gas train
Part no.
NotesBurner/gas train
adapterPart no.
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.
Regulatorwith incorporated filter
Part no.
P.Max**mbar
Curveon
graphExecution
Execution
VersionGastype
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
7272
BGN 508
6
4
2
0
mbar
100 200 300 400 500 600 700
10 20 30 40 50 60 70
42 6 8 10 12 14 16 18 20 22 24 26
mn3/h
mn3/h
kWMetano
G.P.L.
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Single stage operation (on/off).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Manual air flow adjustment.• Possibility to chose gas train with valve tightness
control.• Equipped with one flange and one insulating seal
for boiler fastening.• On request: longer blast tube and device for air
gate closure during pause to avoid loss of heatup flue.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by ionisation electrode.• Control panel comprising stop/go switch, and
operation and block indicators.• Terminal block for the electrical and thermostatic
connections to the burner.• Electrical protection rating IP40.
BGN 50 from 169 to 596 kWSingle-stage gas burners
0002
4705
81/2
-T B1B5
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN676
5) Valve tightness control not required by EN676.CTV )Gas train with Valve Tightness Control.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Boiler coupling kit
Gas burner accessories
OptionalsDescription500 mm long combustion head Automatic Air Closure Device
Notes
Part no. Description97980054 Soundproof burner cover
Accessories available on request
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
169 ÷ 596 BGN 50 16050010 3N AC 50Hz 400V 0,37 470 295 102 1150 210 ÷ 400 135 1260 x 660 x 680 65
169 ÷ 596 BGN 50 16055410 3N AC 60Hz 400V 0,55 470 295 102 1150 210 ÷ 400 135 1260 x 660 x 680 65
Frequency 50 Hz
Frequency 60 Hz
Natural gas
LPG
7373
BGN 50 from 169 to 596 kWGas train
8A 360 19990411 Included — B2
8B 360 19990410 Included — B2
8C360 19990404 Included — B2
CECTV 360 19990454 Included — B2 5)
8D360 19990405 Included 96000013 B2
NATURALCTV 360 19990455 Included 96000013 B2 5)
BGN 50GAS
8A 360 19990411 Included — B2
8B 360 19990410 Included — B2
8C360 19990404 Included — B2
EXP CTV 360 19990454 Included — B2
8D360 19990405 Included 96000013 B2
CTV 360 19990455 Included 96000013 B2
8J 40 19990062 — — ME4
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 50 metanoCE
ediz.02/2004
0123456789
101112131415161718192021222324252627282930313233343536373839404142
100 150 200 250 300 350 400 450 500 550 600 650
PORTATA kW
PR
ES
SIO
NE
m
bar
8C
8B
8A
8D
Perdite di carico(testa di combustione + rampa gas)
BGN 50 metanoEXP
ediz.02/2004
0123456789
101112131415161718192021222324252627282930313233343536373839404142
100 150 200 250 300 350 400 450 500 550 600 650
PORTATA kW
PR
ES
SIO
NE
m
bar
8C
8B
8A
8J
8D
CE30 19990411 Included — B2
BGN 50 LPGCTV 30 19990438 97390050 96000006 B4 5)
EXP30 19990411 Included — B2
CTV 30 19990438 — 96000006 BE4
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type
Burnermodel Pic.
Gas train
Part no.
Gas train
Part no.
NotesBurner/gas train
adapterPart no.
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.
Regulatorwith incorporated filter
Part no.
P.Max**mbar
Curveon
graphExecution
Execution
VersionGastype
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gasHead loss(combustion head + gas train)
Pres
sure
Thermal output
Natural gas
7474
Series BTG...P from 16,3 to 99 kWTwo-stage gas burners
BTG 3.6P BTG 6P BTG 11P
0002922221/1-T
10 100 110
0.5
1
1
1.5
1.5 2.5 3.5
20
2
2
2.5
30
3
43
40 50 60 70 80 90
111
0.5
0
1098765432
mbar
kWMetano
G.P.L.
mn3/h
mn3/h
A
D
C
ØF
B5B1
1° 30'
0002
4705
81-T
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• Possibility to chose gas train with valve tightnesscontrol.
• Equipped with one 4 and 7 pole connector, oneflange and one insulating seal for boilerfastening.
• On request: longer blast tube.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air inlet with device to adjust the air
flow; automatically closing air gate.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable combustion head complete with blast
tube (stainless steel for BTG 11) and steeldeflector disk.
• Monophase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by ionisation electrode.• 7 pole outlet for burner electrical and thermostat
connections, and 4 pole outlet for second stagecontrol.
• Prepared for microamperometer connection withionisation cable.
• Electrical protection rating IP40.• Sound-proof plastic protective cover.
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
1) Equipped with air closure device.5) Valve tightness control not required by EN676.CTV)Gas train with Valve Tightness Control.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Boiler coupling kit - 4 and 7 pin plug
Gas burner accessories
OptionalsDescription300 mm long combustion head
Notes
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
16,3 ÷ 41,9 BTG 3,6 P 17030010 1N AC 50Hz 230V 0,11 245 218,5 53 410 50 ÷ 105 90 500 x 300 x 320 12 1)
30,6 ÷ 56,3 BTG 6 P 17050010 1N AC 50Hz 230V 0,11 245 218,5 53 410 50 ÷ 105 90 500 x 300 x 320 12 1)
48,8 ÷ 99 BTG 11 P 17070010 1N AC 50Hz 230V 0,11 245 218,5 53 475 90 ÷ 150 90 540 x 300 x 320 12 1)
16,3 ÷ 41,9 BTG 3,6 P 17030010 1N AC 60Hz 230V 0,11 245 218,5 53 410 50 ÷ 105 90 500 x 300 x 320 12 1)
30,6 ÷ 56,3 BTG 6 P 17050010 1N AC 60Hz 230V 0,11 245 218,5 53 410 50 ÷ 105 90 500 x 300 x 320 12 1)
48,8 ÷ 99 BTG 11 P 17070010 1N AC 60Hz 230V 0,11 245 218,5 53 475 90 ÷ 150 90 540 x 300 x 320 12 1)
0085
Frequency 50 Hz
Frequency 60 Hz
Natural gas
LPG
7575
BTG 3,6P LPG CE / EXP30 19990016 Included — — B2
CTV 30 19990016 Included — 98000100 B2 5)
BTG 3,6 P from 16,3 to 41,9 kWGas train
BTG 3,6PNATURAL
CE / EXP 9A360 19990016 Included — — B2
GAS CTV 360 19990016 Included — 98000100 B2 5)
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BTG 3,6P metanoEXP
ediz.04/2003
0,0
0,5
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0
5,5
10 15 20 25 30 35 40 45 50
PORTATA kW
PR
ES
SIO
NE
m
bar
9A
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type
Burnermodel Pic.
Gas train
Part no.
Gas train
Part no.
NotesBurner/gas train
adapterPart no.
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.
Regulatorwith incorporated filter
Part no.
P.Max**mbar
Curveon
graphExecution
Execution
VersionGastype
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
7676
BTG 6 P from 30,6 to 56,3 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BTG 6P metanoEXP
ediz.04/2003
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0
5,5
6,0
6,5
7,0
25 30 35 40 45 50 55 60 65
PORTATA kW
PR
ES
SIO
NE
m
bar
10A
BTG 6P LPG CE / EXP30 19990016 Included — — B2
CTV 30 19990016 Included — 98000100 B2 5)
BTG 6PNATURAL
CE / EXP 10A360 19990016 Included — — B2
GAS CTV 360 19990016 Included — 98000100 B2 5)
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type
Burnermodel Pic.
Gas train
Part no.
Gas train
Part no.
NotesBurner/gas train
adapterPart no.
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.
Regulatorwith incorporated filter
Part no.
P.Max**mbar
Curveon
graphExecution
Execution
VersionGastype
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
7777
BTG 11P LPG CE / EXP30 19990016 Included — — B2
CTV 30 19990016 Included — 98000100 B2 5)
BTG 11PNATURAL
CE / EXP 11A360 19990016 Included — — B2
GAS CTV 360 19990016 Included — 98000100 B2 5)
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
BTG 11 P from 48,8 to 99 kWGas train
Perdite di carico(testa di combustione + rampagas + regolatore di pressione)
BTG 11P metanoCE / EXP
ediz.03/2003
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
40 45 50 55 60 65 70 75 80 85 90 95 100 105
PORTATA kW
PR
ES
SIO
NE
m
bar
11A
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type
Burnermodel Pic.
Gas train
Part no.
Gas train
Part no.
NotesBurner/gas train
adapterPart no.
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.
Regulatorwith incorporated filter
Part no.
P.Max**mbar
Curveon
graphExecution
Execution
VersionGastype
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
787878
BTG 20 P from 60 to 205 kWTwo-stage gas burners with low pollutant emission
0
1
2
3
4
5
6
7
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 kW
mbar BTG 20
0002
4709
90-T
D
B5
B1 flF
CA
BTECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe.• Burnt gas recycling blast-pipe able to achieve
very low pollutant emissions, particularly withregard to nitrous oxides (NOx).
• Maintenance facilitated by the fact that the mixingunit can be removed without having to removethe burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• Possibility to chose gas train with valve tightnesscontrol.
• Equipped with one 4 and 7 pole connector, oneflange and one insulating seal for boilerfastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air inlet with device to adjust the air
flow; automatically closing air gate.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Monophase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by ionisation electrode.• 7 pole outlet for burner electrical and thermostat
connections, and 4 pole outlet for second stagecontrol.
• Prepared for microamperometer connection withionisation cable.
• Electrical protection rating IP40.• Sound-proof plastic protective cover.
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
1) Equipped with air closure device.5) Valve tightness control not required by EN676.CTV)Gas train with Valve Tightness Control.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Boiler coupling kit - 4 and 7 pin plug
Gas burner accessories
Notes
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
0085
Frequency 50 Hz
Frequency 60 Hz60 ÷ 205 BTG 20 P 17110010 1N AC 50Hz 230V 0,18 303 275 70 695 150 ÷ 300 114 710 x 370 x 410 15 1
60 ÷ 205 BTG 20 P 17110010 1N AC 60Hz 230V 0,18 303 275 70 695 150 ÷ 300 114 710 x 370 x 410 15 1
LOWNOx
NEW
797979
BTG 20 P from 60 to 205 kWGas train
Perdite di carico(testa di combustione + rampagas + regolatore di pressione)
BTG 20P metanoCE / EXP
ediz.03/2004
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
25 50 75 100 125 150 175 200 225
PORTATA kW
PR
ES
SIO
NE
m
bar
44A
44C
44B
BTG 20P LPG CE / EXP30 19990016 Included — — B2
CTV 30 19990016 Included — 98000100 B2 5)
44A360 19990016 Included — — B2
CTV 360 19990016 Included — 98000100 B2 5)
BTG 20PNATURAL
44B360 19990020 Included — — B2
GASCE / EXP
CTV 360 19990020 Included — 98000100 B2 5)
44C360 19990024 Included 96000031 — B2
CTV 360 19990024 Included 96000031 98000100 B2 5)
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type
Burnermodel Pic.
Gas train
Part no.
Gas train
Part no.
NotesBurner/gas train
adapterPart no.
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.
Regulatorwith incorporated filter
Part no.
P.Max**mbar
Curveon
graphExecution
Execution
VersionGastype
Head loss (combustion head +gas train + pressure regulator)
Pres
sure
Thermal output
Natural gas
8080
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• Possibility to chose gas train with valve tightnesscontrol.
• Equipped with one 4 and 7 pole connector, oneflange and one insulating seal for boilerfastening.
• On request: longer blast tubel.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Monophase electric motor to run fan.• Device made from sound-absorbing material to
reduce fan noise.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by ionisation electrode.• Start/stop switch, 1st /2nd stage selector (except
the W version).• 7 pole outlet for burner electrical and thermostat
connections, and 4 pole outlet for second stage control.• Electrical protection rating IP40.• Sound-proof plastic protective cover (except the
W version).
Series SPARKGAS 30P/30PW from 60 to 300 kW Two-stage gas burners
0002
9219
53-T
14
4036
400360
mbar
2 6 10
8
6
4
12
320
32
84
2802402001601208040
2824201612840
2
n
n
3
3
m / h G.P.L.
kW
m / h Metano
SPARKGAS 35P - 35PW SPARKGAS 30P - 30PW
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
3) Soundproof lid on burner air intake.4) Equipped with automatic device for air closing.5) Valve tightness control not required by EN676.CTV)Gas train with Valve Tightness Control. *) Minimum gas train inlet pressure needed to obtain maximum burner power with a
combustion chamber backpressure of zero.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Boiler coupling kit - 4 and 7 pin plug
Gas burner accessories
OptionalsDescription500 mm long combustion head
Notes
Part no. Description97980054 Soundproof burner cover
Accessories available on request
0085B1
B5
0002
4705
81/1
-TB1B5
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
60 ÷ 300 SPARKGAS 30 PW 15690010 1N AC 50Hz 230V 0,37 460 263 102 835 170 ÷ 300 135 1010 x 490 x 390 32 3) 4)
60 ÷ 300 SPARKGAS 30 P 15710010 1N AC 50Hz 230V 0,37 490 275 102 860 170 ÷ 300 135 980 x 540 x 480 36 3) 4)
60 ÷ 300 SPARKGAS 30 PW 15695410 1N AC 60Hz 230V 0,37 460 263 102 835 170 ÷ 300 135 1010 x 490 x 390 32 3) 4)
60 ÷ 300 SPARKGAS 30 P 15715410 1N AC 60Hz 230V 0,37 490 275 102 860 170 ÷ 300 135 980 x 540 x 480 36 3) 4)
Frequency 50 Hz
Frequency 60 Hz
Natural gas
LPG
8181
SPARKGAS 30P/30PW from 60 to 300 kWGas train
Perdite di carico(testa di combustione + rampagas + regolatore di pressione)
SPARKGAS 30P/30PW metanoCE / EXP
ediz.03/2003
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
25 50 75 100 125 150 175 200 225 250 275 300 325
PORTATA kW
PR
ES
SIO
NE
m
bar
13A
13C
13B
13A360 19990020 Included 96000005 — B2
CTV 360 19990020 Included 96000005 98000100 B2 5)
SPARKGAS 30P NATURAL13B
360 19990024 Included — — B2
SPARKGAS 30PW GASCE / EXP
CTV 360 19990024 Included — 98000100 B2 5)
13C360 19990168 Included — — B2
CTV 360 19990168 Included — 98000100 B2 5)
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type
Burnermodel Pic.
Gas train
Part no.
Gas train
Part no.
NotesBurner/gas train
adapterPart no.
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.
Regulatorwith incorporated filter
Part no.
P.Max**mbar
Curveon
graphExecution
Execution
VersionGastype
Head loss (combustion head +gas train + pressure regulator)
Pres
sure
Thermal output
Natural gas
SPARKGAS 30P 30 19990020 Included 96000005 — B2
SPARKGAS 30PWLPG CE / EXP
CTV 30 19990020 Included 96000005 98000100 B2 5)
828282
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• Possibility to chose gas train with valve tightnesscontrol.
• Equipped with one 4 and 7 pole connector, oneflange and one insulating seal for boilerfastening.
• On request: longer blast tubel.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Monophase electric motor to run fan.• Device made from sound-absorbing material to
reduce fan noise.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by ionisation electrode.• Start/stop switch, 1st /2nd stage selector (except
the W version).• 7 pole outlet for burner electrical and thermostat
connections, and 4 pole outlet for second stage control.• Electrical protection rating IP40.• Sound-proof plastic protective cover (except the
W version).
Series SPARKGAS 35P/35PW from 90 to 358 kW Two-stage gas burners
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
3) Soundproof lid on burner air intake.4) Equipped with automatic device for air closing.5) Valve tightness control not required by EN676.CTV)Gas train with Valve Tightness Control. *) Minimum gas train inlet pressure needed to obtain maximum burner power with a
combustion chamber backpressure of zero.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Boiler coupling kit - 4 and 7 pin plug
Gas burner accessories
OptionalsDescription500 mm long combustion head
Notes
Part no. Description97980054 Soundproof burner cover
Accessories available on request
0085B1
B5
0002
4705
81/1
-TB1B5
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Frequency 50 Hz
Frequency 60 Hz
90 ÷ 358 SPARKGAS 35 PW 15750010 1N AC 50Hz 230V 0,37 475 263 102 925 130 ÷ 350 135 1010 x 490 x 390 32 3) 4)
90 ÷ 358 SPARKGAS 35 P 15770010 1N AC 50Hz 230V 0,37 490 275 102 965 130 ÷ 350 135 1100 x 540 x 480 36 3) 4)
90 ÷ 358 SPARKGAS 35 PW 15755410 1N AC 60Hz 230V 0,37 475 263 102 925 130 ÷ 350 135 1010 x 490 x 390 32 3) 4)
90 ÷ 358 SPARKGAS 35 P 15775410 1N AC 60Hz 230V 0,37 490 275 102 965 130 ÷ 350 135 1100 x 540 x 480 36 3) 4)
0002
9219
53-T
14
4036
400360
mbar
2 6 10
8
6
4
12
320
32
84
2802402001601208040
2824201612840
2
n
n
3
3
m / h G.P.L.
kW
m / h Metano
SPARKGAS 35P - 35PW SPARKGAS 30P - 30PW
Natural gas
LPG
8383
SPARKGAS 35P/35PW from 90 to 358 kW Gas train
Perdite di carico(testa di combustione + rampagas + regolatore di pressione)
SPARKGAS 35P/35PW metanoCE / EXP
ediz.02/2004
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
50 75 100 125 150 175 200 225 250 275 300 325 350 375 400
PORTATA kW
PR
ES
SIO
NE
m
bar
14A
14C
14B
14A360 19990020 Included 96000005 — B2
CTV 360 19990020 Included 96000005 98000100 B2 5)
SPARKGAS 35P NATURAL14B
360 19990024 Included — — B2
SPARKGAS 35PW GASCE / EXP
CTV 360 19990024 Included — 98000100 B2 5)
14C360 19990168 Included — — B2
CTV 360 19990168 Included — 98000100 B2 5)
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type
Burnermodel Pic.
Gas train
Part no.
Gas train
Part no.
NotesBurner/gas train
adapterPart no.
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.
Regulatorwith incorporated filter
Part no.
P.Max**mbar
Curveon
graphExecution
Execution
VersionGastype
Head loss (combustion head +gas train + pressure regulator)
Pres
sure
Thermal output
Natural gas
SPARKGAS 35P 30 19990020 Included 96000005 — B2
SPARKGAS 35PWLPG CE / EXP
CTV 30 19990020 Included 96000005 98000100 B2 5)
8484
3
3
BGN120PBGN100PBGN60PBGN40PBGN120DSPGN
504846
130120
13001200kW
n
n
m /h G.P.L.
m /h Metano
444240383634323028262422201816141210864
1101009080706050403020
11001000900800700600500400300200
10
100
0002
9222
81-T
BGN60DSPGNBGN40DSPGN BGN100DSPGNBGN120DSPGN MEBGN60DSPGN MEBGN40DSPGN ME BGN100DSPGN ME
mbar14
12
10
0
8
6
4
2
0002
4705
81/2
-T B1B5
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• Possibility to chose gas train with valve tightnesscontrol.
• Equipped with one flange and one insulating sealfor boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by ionisation electrode.• Control panel comprising stop/go switch, 1st/2nd
stage selector, operation and block indicator.• Terminal block for the electrical and thermostatic
connections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
Series BGN...P from 185 to 995 kWTwo-stage gas burners
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
4) Equipped with automatic device for air closing.5) Valve tightness control not required by EN676.6) Where gas pressure at the safety valve is less than 12mbar, replace the
minimum pressure switch with a GW50 pressure switch.CTV) Gas train with Valve Tightness Control.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.**) Maximum gas pressure at pressure regulator in CE version, at gas train for
EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Boiler coupling kit
Gas burner accessories
Notes
Part no. Description97980054 Soundproof burner cover for BGN 4097980055 Soundproof burner cover for BGN 60-100
Accessories available on request
0085
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
185 ÷ 425 BGN 40 P 16060010 3N AC 50Hz 400V 0,37 470 295 102 1100 150 ÷ 330 135 1260 x 660 x 680 63 4)
248 ÷ 738 BGN 60 P 16510010 3N AC 50Hz 400V 1,1 560 365 120 1270 170 ÷ 400 160 1510 x 750 x 720 88 4)
280 ÷ 995 BGN 100 P 16560010 3N AC 50Hz 400V 1,1 560 365 120 1330 240 ÷ 460 160 1510 x 750 x 720 91 4)
185 ÷ 425 BGN 40 P 16065410 3N AC 60Hz 400V 0,55 470 295 102 1100 150 ÷ 330 135 1260 x 660 x 680 63 4)
248 ÷ 738 BGN 60 P 16515410 3N AC 60Hz 400V 1,5 560 365 120 1270 170 ÷ 400 160 1510 x 750 x 720 88 4)
280 ÷ 995 BGN 100 P 16565410 3N AC 60Hz 400V 1,5 560 365 120 1330 240 ÷ 460 160 1510 x 750 x 720 91 4)
Frequency 50 Hz
Frequency 60 Hz
Natural gas
LPG
8585
BGN 40 P from 185 to 425 kWGas train
Perdite di carico(testa di combustione + rampagas + regolatore di pressione)
BGN 40P metanoCE / EXP
ediz.03/2003
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
150 175 200 225 250 275 300 325 350 375 400 425 450
PORTATA kW
PR
ES
SIO
NE
m
bar
15A
15C
15B
15A 360 19990411 Included — B2
BGN 40PNATURAL
CE / EXP15B 360 19990410 Included — B2
GAS15C
360 19990404 Included — B2
CTV 360 19990454 Included — B2 5)
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
CE30 19990411 Included — B2
BGN 40P LPGCTV 30 19990436 97390030 96000005 B4 5)
EXP30 19990411 Included — B2
CTV 30 19990436 — 96000005 BE4
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type
Burnermodel Pic.
Gas train
Part no.
Gas train
Part no.
NotesBurner/gas train
adapterPart no.
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.
Regulatorwith incorporated filter
Part no.
P.Max**mbar
Curveon
graphExecution
Execution
VersionGastype
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
8686
BGN 60 P from 248 to 738 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 60P metanoCE
ediz.02/2004
0
1
23
4
5
6
78
9
10
11
1213
14
15
16
1718
19
20
21
22
2324
25
26
27
2829
30
31
32
3334
35
36
37
3839
40
41
200 250 300 350 400 450 500 550 600 650 700 750 800
PORTATA kW
PR
ES
SIO
NE
m
bar
16B
16C
16A
16D
colore molla regolatore
verde
neutra
Perdite di carico(testa di combustione + rampa gas)
BGN 60P metanoEXP
ediz.02/2004
0
1
23
4
5
6
78
9
10
11
1213
14
15
16
1718
19
20
21
22
2324
25
26
27
2829
30
31
32
3334
35
36
37
3839
40
41
200 250 300 350 400 450 500 550 600 650 700 750 800
PORTATA kW
PR
ES
SIO
NE
m
bar
16B
16C
16A
16J
CE30 19990410 Included — B2
BGN 60P LPGCTV 30 19990438 97390050 96000008 B4 5)
EXP30 19990410 Included — B2
CTV 30 19990438 — 96000008 BE4
16A 360 19990410 Included — B2
16B360 19990404 Included — B2
CTV 360 19990454 Included — B2 5)
CE16C
360 19990405 Included — B2
CTV 360 19990455 Included — B2 5)
16D200 19990456 97390700 — B4 6)
BGN 60PNATURAL CTV 200 19990457 97390700 — B4 5) 6)
GAS 16A 360 19990410 Included — B2
16B360 19990404 Included — B2
CTV 360 19990454 Included — B2
EXP16C
360 19990405 Included — B2
CTV 360 19990455 Included — B2
16J140 19990456 — — BE4 6)
CTV 140 19990457 — — BE4 6)
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type Gas train
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.Execution
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gasHead loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
Regulatorspring colour
greenneutral
8787
BGN 100 P from 280 to 995 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 100P metanoCE
ediz.02/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
65
20 30 40 50 60 70 80 90 100 110
PORTATA kW x10
PR
ES
SIO
NE
m
bar
17B
17C
17A
17D
17E
17F
colore molla regolatore
verde
neutra
Perdite di carico(testa di combustione + rampa gas)
BGN 100P metanoEXP
ediz.02/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
65
20 30 40 50 60 70 80 90 100 110
PORTATA kW x10
PR
ES
SIO
NE
m
bar
17B
17C
17A
17J
17K
17L
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
17A 360 19990410 Included — B2
17B360 19990404 Included — B2
CTV 360 19990454 Included — B2 5)
17C360 19990405 Included — B2
CTV 360 19990455 Included — B2 5)
CE17D
200 19990456 97390700 — B4 6)
CTV 200 19990457 97390700 — B4 5) 6)
17E200 19990458 97390700 — B4 6)
CTV 200 19990459 97390700 — B4 5) 6)
17F200 19990460 97390700 96005006 B5 6)
NATURAL CTV 200 19990461 97390700 96005006 B5 5) 6)BGN 100P
GAS 17A 360 19990410 Included — B2
17B360 19990404 Included — B2
CTV 360 19990454 Included — B2
17C360 19990405 Included — B2
CTV 360 19990455 Included — B2
EXP17J
140 19990456 — — BE4 6)
CTV 140 19990457 — — BE4 6)
17K140 19990458 — — BE4 6)
CTV 140 19990459 — — BE4 6)
17L140 19990460 — 96005006 BE5 6)
CTV 140 19990461 — 96005006 BE5 6)
BGN 100P LPG CE / EXP30 19990404 Included — B2
CTV 30 19990454 Included — B2 5)
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type Gas train
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.Execution
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gasHead loss(combustion head + gas train)
Pres
sure
Thermal output
Natural gas
Regulatorspring colour
greenneutral
8888
0002
4705
81/2
-T B1B5
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• Possibility to chose gas train with valve tightnesscontrol.
• Equipped with one flange and one insulating sealfor boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by ionisation electrode.• Control panel comprising stop/go switch, 1st/2nd
stage selector, operation and block indicator.• Terminal block for the electrical and thermostatic
connections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
BGN 120 P from 350 to 1200 kWTwo-stage gas burners
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
Boiler coupling kit
Gas burner accessories
Part no. Description97980055 Soundproof burner cover
On request
0085
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
4) Equipped with automatic device for air closing.5) Valve tightness control not required by EN676.6) Where gas pressure at the safety valve is less than 12mbar, replace the
minimum pressure switch with a GW50 pressure switch.CTV)Gas train with Valve Tightness Control.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.**) Maximum gas pressure at pressure regulator in CE version, at gas train for
EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Notes
350 ÷ 1200 BGN 120 P 16610010 3N AC 50Hz 400V 1,5 590 365 137 1400 220 ÷ 440 195 1510 x 750 x 720 100 4)
350 ÷ 1200 BGN 120 P 16615410 3N AC 60Hz 400V 2,6 590 365 137 1400 220 ÷ 440 195 1510 x 750 x 720 100 4)
Frequency 50 Hz
Frequency 60 Hz
3
3
BGN120PBGN100PBGN60PBGN40PBGN120DSPGN
504846
130120
13001200kW
n
n
m /h G.P.L.
m /h Metano
444240383634323028262422201816141210864
1101009080706050403020
11001000900800700600500400300200
10
100
0002
9222
81-T
BGN60DSPGNBGN40DSPGN BGN100DSPGNBGN120DSPGN MEBGN60DSPGN MEBGN40DSPGN ME BGN100DSPGN ME
mbar14
12
10
0
8
6
4
2
Natural gas
LPG
8989
BGN 120 P from 350 to 1200 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 120P metanoCE
ediz.04/2003
0123456789
1011121314151617181920212223242526272829303132333435363738394041424344
20 30 40 50 60 70 80 90 100 110 120 130
PORTATA kW x10
PR
ES
SIO
NE
m
bar
18B
18C
18A
18D
18E
18F
colore molla regolatore
verde
neutra
18A360 19990404 Included 96000009 B2
CTV 360 19990454 Included 96000009 B2 5)
18B360 19990405 Included — B2
CTV 360 19990455 Included — B2 5)
18C200 19990456 97390700 — B4 6)
CECTV 200 19990457 97390700 — B4 5) 6)
18D200 19990458 97390700 — B4 6)
CTV 200 19990459 97390700 — B4 5) 6)
18E200 19990460 97390700 96005002 B5 6)
CTV 200 19990461 97390700 96005002 B5 5) 6)
18F200 19990462 97390710 96005007 B5
BGN 120 PNATURAL CTV 200 19990463 97390710 96005007 B5 5)
GAS18A
360 19990404 Included 96000009 B2
CTV 360 19990454 Included 96000009 B2
18B360 19990405 Included — B2
CTV 360 19990455 Included — B2
18J140 19990456 — — BE4 6)
EXPCTV 140 19990457 — — BE4 6)
18K140 19990458 — — BE4 6)
CTV 140 19990459 — — BE4 6)
18L140 19990460 — 96005002 BE5 6)
CTV 140 19990461 — 96005002 BE5 6)
18M140 19990462 — 96005007 BE5
CTV 140 19990463 — 96005007 BE5
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
BGN 120 P LPG CE / EXP30 19990404 Included 96000009 B2
CTV 30 19990454 Included 96000009 B2 5)
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type Gas train
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.Execution
Head loss (combustion head + gas train+ pressure regulator)
Pres
sure
Thermal output
Natural gas Head loss (combustion head + gas train)
Pres
sure
Thermal output
Natural gas
Regulatorspring colour
greenneutral
9090
BGN 150P
BGN 200P BGN 250P
BGN 300P
BGN 350P
mn3/h
mn3/h
kWMetano
G.P.L.40 80 120 160 200 240 280
400 800 1200 1600 2000 2400 2800 3200
320 360 400
3600 4000
10 20 30 40 50 60 70 110 120 130 140 1501009080
17.5
15
12.5
10
20
7.5
5
2.5
0
mbar
BT76
05_5
-T
0002
4705
81/2
-T B1B5
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• Valves tightness control compliant with Europeanstandard EN676 in the CE execution; on requestin the EXP execution.
• Equipped with one flange and one insulating sealfor boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, valves seal control, minimum pressureswitch, pressure regulator and gas filter.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by ionisation electrode.• Control panel comprising stop/go switch, 1st/2nd
stage selector, operation and block indicator.• Terminal block for the electrical and thermostatic
connections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
Series BGN...P from 414 to 3500 kWTwo-stage gas burners
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
Boiler coupling kit
Gas burner accessories
Part no. Description97980055 Soundproof burner cover for BGN 15097980057 Soundproof burner cover for BGN 200-250-300-350
Accessories available on request
0085
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
4) Equipped with automatic device for air closing.6) Where gas pressure at the safety valve is less than 12mbar, replace the
minimum pressure switch with a GW50 pressure switch.7) Regulator and filter are supplied separately: both must be ordered.CTV)Gas train with Valve Tightness Control.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.**) Maximum gas pressure at pressure regulator in CE version, at gas train for
EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Notes
414 ÷ 1428 BGN 150 P 16660010 3N AC 50Hz 400V 2,2 655 450 137 1500 220 ÷ 440 195 1730 x 1030 x 880 148 4)
590 ÷ 2000 BGN 200 P 16710010 3N AC 50Hz 400V 3 830 580 150 1850 300 ÷ 600 220 2030 x 1210 x 990 220 4)
490 ÷ 2500 BGN 250 P 16760010 3N AC 50Hz 400V 7,5 875 580 150 1850 300 ÷ 600 220 2030 x 1210 x 990 249 4)
657 ÷ 2982 BGN 300 P 16810010 3N AC 50Hz 400V 7,5 875 580 177 1850 275 ÷ 465 275 2030 x 1210 x 990 286 4)
924 ÷ 3500 BGN 350 P 16860010 3N AC 50Hz 400V 7,5 880 580 177 1850 275 ÷ 465 275 2030 x 1210 x 990 290 4)
414 ÷ 1428 BGN 150 P 16665410 3N AC 60Hz 400V 3,4 655 450 137 1500 220 ÷ 440 195 1730 x 1030 x 880 148 4)
590 ÷ 2000 BGN 200 P 16715410 3N AC 60Hz 400V 3,5 830 580 150 1850 300 ÷ 600 220 2030 x 1210 x 990 220 4)
490 ÷ 2500 BGN 250 P 16765410 3N AC 60Hz 400V 9 875 580 150 1850 300 ÷ 600 220 2030 x 1210 x 990 249 4)
657 ÷ 2982 BGN 300 P 16815410 3N AC 60Hz 400V 9 875 580 177 1850 275 ÷ 465 275 2030 x 1210 x 990 286 4)
924 ÷ 3500 BGN 350 P 16865410 3N AC 60Hz 400V 9 880 580 177 1850 275 ÷ 465 275 2030 x 1210 x 990 290 4)
Frequency 50 Hz
Frequency 60 Hz
Natural gas
LPG
9191
19A 360 19990454 Included 96000009 B2
19B 360 19990455 Included — B2
CE19C 200 19990457 97390700 — B4 6)
19D 200 19990459 97390700 — B4 6)
19E 200 19990461 97390700 96005002 B5 6)
19F 200 19990463 97390710 96005007 B5
19J360 19990404 Included 96000009 B2
CTV 360 19990454 Included 96000009 B2
NATURAL19K
360 19990405 Included — B2BGN 150P
GAS CTV 360 19990455 Included — B2
19L140 19990456 — — BE4 6)
EXP CTV 140 19990457 — — BE4 6)
19M140 19990458 — — BE4 6)
CTV 140 19990459 — — BE4 6)
19N140 19990460 — 96005002 BE5 6)
CTV 140 19990461 — 96005002 BE5 6)
19P140 19990462 — 96005007 BE5
CTV 140 19990463 — 96005007 BE5
BGN 150 P from 414 to 1428 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 150P metanoCE
ediz.04/2003
0
5
10
15
20
25
30
35
40
45
50
55
30 40 50 60 70 80 90 100 110 120 130 140 150 160
PORTATA kW x10
PR
ES
SIO
NE
m
bar
19B
19C
19A
19D
19E
19F
colore molla regolatore
verde
neutra
CE 30 19990454 Included 96000009 B2
BGN 150P LPGEXP
30 19990404 Included 96000009 B2
CTV 30 19990454 Included 96000009 B2
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type Gas train
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.Execution
Head loss (combustion head + gas train+ pressure regulator)
Pres
sure
Thermal output
Natural gasHead loss (combustion head + gas train)
Pres
sure
Thermal output
Natural gas
Regulatorspring colour
greenneutral
9292
BGN 200 P from 590 to 2000 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 200P metanoCE
ediz.02/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
0 5 10 15 20 25
PORTATA kW x100
PR
ES
SIO
NE
m
bar
20B
20C
20D
20E
20F
20A
colore molla regolatore
verde
neutra
rossa
Perdite di carico(testa di combustione + rampa gas)
BGN 200P metanoEXP
ediz.02/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
0 5 10 15 20 25
PORTATA kW x100
PR
ES
SIO
NE
m
bar
20K
20M
20N
20P
20Q
20J
20L
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Burnermodel Pic.
Gas train
Part no.Notes
Gasfilter
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorpo-rated filter without filter
Part no. Part no.
P.Max**mbar
Curveon
graphExecutionVersionGas
type
20A 360 19990454 Included — 96000011 B2
20B 360 19990455 Included — 96000012 B2
CE20C 200 19990459 97390700 — 96000012 B4 6)
20D 200 19990461 97390700 — — B5 6)
20E 200 19990463 97390710 — 96005004 B5
20F 200 19990465 97390720 97439999 96005004 B5 7)
20J360 19990404 Included — 96000011 B2
CTV 360 19990454 Included — 96000011 B2
20K360 19990405 Included — 96000012 B2
BGN 200PNATURAL CTV 360 19990455 Included — 96000012 B2
GAS20L
140 19990456 — — 96000012 BE4 6)
CTV 140 19990457 — — 96000012 BE4 6)
EXP 20M140 19990458 — — 96000012 BE4 6)
CTV 140 19990459 — — 96000012 BE4 6)
20N140 19990460 — — — BE5 6)
CTV 140 19990461 — — — BE5 6)
20P140 19990462 — — 96005004 BE5
CTV 140 19990463 — — 96005004 BE5
20Q140 19990464 — — 96005004 BE5
CTV 140 19990465 — — 96005004 BE5
CE 30 19990457 97390700 96000012 B4
BGN 200P LPGEXP
30 19990456 — 96000012 BE4
CTV 30 19990457 — 96000012 BE4
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type Gas train
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.Execution
Head loss (combustion head + gas train+ pressure regulator)
Pres
sure
Thermal output
Natural gasHead loss (combustion head + gas train)
Pres
sure
Thermal output
Natural gas
Regulatorspring colour
greenneutralred
9393
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 250P metanoCE
ediz.04/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
0 5 10 15 20 25 30
PORTATA kW x100
PR
ES
SIO
NE
m
bar
21B
21C
21E
21A
colore molla regolatore
verde
neutra
rossa
21D
BGN 250 P from 490 to 2500 kWGas train
CE 33 19990457 97390700 96000012 B4
BGN 250P LPGEXP
30 19990456 — 96000012 BE4
CTV 30 19990457 — 96000012 BE4
21A200 19990457 97390700 — 96000012 B4 6)
500 19990457 97390730 — 96000012 B4 6)
CE21B 200 19990459 97390700 — 96000012 B4 6)
21C 200 19990461 97390700 — 96005003 B5 6)
21D 200 19990463 97390710 — — B5
21E 200 19990465 97390720 97439999 — B5 7)
21J140 19990456 — — 96000012 BE4 6)
NATURAL CTV 140 19990457 — — 96000012 BE4 6)BGN 250P
GAS21K21K
140 19990458 — — 96000012 BE4 6)
CTV 140 19990459 — — 96000012 BE4 6)
EXP 21L140 19990460 — — 96005003 BE5 6)
CTV 140 19990461 — — 96005003 BE5 6)
21M140 19990462 — — — BE5
CTV 140 19990463 — — — BE5
21N140 19990464 — — — BE5
CTV 140 19990465 — — — BE5
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Gasfilter
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorpo-rated filter without filter
Part no. Part no.
P.Max**mbar
Curveon
graphExecutionVersionGas
type
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type Gas train
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.Execution
Head loss (combustion head + gas train+ pressure regulator)
Pres
sure
Thermal output
Natural gasHead loss (combustion head + gas train)
Pres
sure
Thermal output
Natural gas
Regulatorspring colour
greenneutralred
9494
BGN 300 P from 657 to 2982 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 300P metanoCE
ediz.04/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
0 5 10 15 20 25 30 35
PORTATA kW x100
PR
ES
SIO
NE
m
bar
22B
22C
22D
22E
22A
colore molla regolatore
verde
neutra
rossa
viola
CE 33 19990459 97390700 — B4
BGN 300P LPGEXP
30 19990458 — — BE4
CTV 30 19990459 — — BE4
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Gasfilter
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorpo-rated filter without filter
Part no. Part no.
P.Max**mbar
Curveon
graphExecutionVersionGas
type
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type Gas train
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.Execution
22A200 19990457 97390700 — — B4 6)
500 19990457 97390730 — — B4 6)
CE22B 200 19990459 97390700 — — B4 6)
22C 200 19990461 97390700 — 96005003 B5 6)
22D 200 19990463 97390710 — 96005004 B5
22E 200 19990465 97390720 97439999 96005004 B5 7)
22J140 19990456 — — — BE4 6)
BGN 300PNATURAL CTV 140 19990457 — — — BE4 6)
GAS22K
140 19990458 — — — BE4 6)
CTV 140 19990459 — — — BE4 6)
EXP 22L140 19990460 — — 96005003 BE5 6)
CTV 140 19990461 — — 96005003 BE5 6)
22M140 19990462 — — 96005004 BE5
CTV 140 19990463 — — 96005004 BE5
22N140 19990464 — — 96005004 BE5
CTV 140 19990465 — — 96005004 BE5
Head loss (combustion head + gas train+ pressure regulator)
Pres
sure
Thermal output
Natural gasHead loss (combustion head + gas train)
Pres
sure
Thermal output
Natural gas
Regulatorspring colour
green
neutral
red
violet
9595
BGN 350 P from 924 to 3500 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 350P metanoCE
ediz.04/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
155
5 10 15 20 25 30 35 40
PORTATA kW x100
PR
ES
SIO
NE
m
bar
23B
23C
23D
23E
23A
colore molla regolatore verde
neutra
rossa
viola
CE 36 19990461 97390700 96005003 B5
BGN 350P LPGEXP
30 19990460 — 96005003 BE5
CTV 30 19990461 — 96005003 BE5
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Gasfilter
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorpo-rated filter without filter
Part no. Part no.
P.Max**mbar
Curveon
graphExecutionVersionGas
type
Burnermodel Pic. NotesP.Gas*
mbarVersionGas
type Gas train
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.Execution
23A200 19990457 97390700 — — B4 6)
500 19990457 97390730 — — B4 6)
CE 23B200 19990459 97390700 — — B4 6)
500 19990459 97390730 — — B4 6)
23C 200 19990461 97390700 — 96005003 B5 6)
23D 200 19990463 97390710 — 96005004 B5
23E 200 19990465 97390720 97439999 96005004 B5 7)
23J140 19990456 — — — BE4 6)
BGN 350PNATURAL CTV 140 19990457 — — — BE4 6)
GAS23K
140 19990458 — — — BE4 6)
CTV 140 19990459 — — — BE4 6)
EXP 23L140 19990460 — — 96005003 BE5 6)
CTV 140 19990461 — — 96005003 BE5 6)
23M140 19990462 — — 96005004 BE5
CTV 140 19990463 — — 96005004 BE5
23N140 19990464 — — 96005004 BE
CTV 140 19990465 — — 96005004 BE5
Head loss (combustion head + gas train+ pressure regulator)
Pres
sure
Thermal output
Natural gas Head loss (combustion head + gas train)
Pres
sure
Thermal output
Natural gas
Regulatorspring colour
greenneutralredviolet
969696
0002
4709
90-T
D
B5
B1 flF
CA
B
BTG 20 LX from 60 to 205 kWProgressive/modulating two-stage gas burners
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
1) Equipped with air closure device.5) Valve tightness control not required by EN676.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
0
1
2
3
4
5
6
7
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 kW
mbar BTG 20
Boiler coupling kit - 4 and 7 pin plug
Gas burner accessories
Modulating modeComplete the burner with the automatic RWF40 regulator and the modulation kit(see page 166).
Notes
LOWNOx
0085
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Frequency 50 Hz
Frequency 60 Hz
Natural gas
NEW
60 ÷ 205 BTG 20 LX 15100010 1N AC 50Hz 230V 0,18 303 275 70 695 150 ÷ 300 114 710 x 370 x 410 18 1)
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage progressive output operation.• Ability to operate with output modulation by
means of automatic RWF40 regulator mounted onthe control panel (to be ordered separately withthe modulation kit).
• Ability to operate with any type of combustionchamber.
• Air-gas mixing at blast-pipe.• Burnt gas recycling blast-pipe able to achieve
very low pollutant emissions, particularly withregard to nitrous oxides (NOx).
• Maintenance facilitated by txhe fact that themixing unit can be removed without having toremove the burner from the boiler.
• Minimum and maximum air flow regulation forfirst and second stage by means of electricservomotor with pause closure of gate to preventany heat dispersion to flue.
• A valve tightness control can be fitted on the burner.• Equipped with one flange and one insulating seal
for boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air inlet with automatically closing
gate to adjust the air flow.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Flame viewer.• Monophase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Monoblock modulating gas train complete with
operation and safety valve, minimum pressureswitch, pressure regulator and gas filter.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by ionisation electrode.• 7 pole outlet for burner electrical and thermostat
connections, and 4 pole outlet for second stage controlor for the connection of the electronic regulator.
• Prepared for microamperometer connection withionisation cable.
• Electrical protection rating IP40.• Sound-proof plastic protective cover.
60 ÷ 205 BTG 20 LX 15100010 1N AC 60Hz 230V 0,18 303 275 70 695 150 ÷ 300 114 710 x 370 x 410 18 1)
979797
BTG 20 LX from 60 to 205 kWGas train
Perdite di carico�(testa di combustione + rampa�gas + regolazione di pressione)�
BTG 20LX metano
ediz.11/2004
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
0 25 50 75 100 125 150 175 200 225
PORTATA kW
PR
ES
SIO
NE
m
bar
45A
45B
CE / EXP
100 19990440 Included — — D3
45A360 19990447 Included — — D3
CTV 100 19990440 Included — 98000100 D3 5)
BTG 20LX NATURALCE / EXP
CTV 360 19990447 Included — 98000100 D3 5)
GAS45B
100 19990441 Included 96000031 — D3
CTV 100 19990441 Included 96000031 98000100 D3 5)
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
9898
A C
D
B1
B5
SPARKGAS 30 LX and LX V from 60 to 340 kWProgressive/modulating two-stage gas burners
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
3) Soundproof lid on burner air intake.4) Equipped with automatic device for air closing.5) Valve tightness control not required by EN676.CTV)Gas train with Valve Tightness Control.**) Maximum gas pressure at pressure regulator in CE version, at gas train for
EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
SPARKGAS 30 LX
50 75 100 125 150 175 200 225 250 275 300 325 350 375
mbar
0,0
0,5
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0
5,5
6,0
6,5
kW
mn2,5 5 7,5 10 12,5 15 17,5 20 22,5 25 27,5 30 32,5 35 37,5
3/h metano
Boiler coupling kit
Gas burner accessories
Modulating modeComplete the burner with the automatic RWF40 regulator and the modulation kit(see page 166).
Notes
LOWNOx
0085 TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage progressive output operation.• Ability to operate with output modulation by
means of automatic RWF40 regulator mounted onthe control panel (to be ordered separately withthe modulation kit).
• Ability to operate with any type of combustionchamber.
• Air-gas mixing at blast-pipe.• Burnt gas recycling blast-pipe able to achieve
very low pollutant emissions, particularly withregard to nitrous oxides (NOx).
• Maintenance facilitated by the fact that the mixingunit can be removed without having to removethe burner from the boiler.
• Minimum and maximum air flow regulation forfirst and second stage by means of electricservomotor with pause closure of gate to preventany heat dispersion to flue.
• Fan speed adjustment in relation to changes inburner demand provided by means of inverter, toobtain a significant reduction in noise levels andelectricity consumption (version V only).
• Possibility to chose gas train with valve tightnesscontrol.
• Equipped with one flange and one insulating sealfor boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Monophase electric motor to run fan (with
electronic inverter control in version V).• Device made from sound-absorbing material to
reduce fan noise.• Air pressure switch to ensure the presence of
combustion air.• Monoblock modulating gas train complete with
operation and safety valve, minimum pressureswitch, pressure regulator and gas filter.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by ionisation electrode.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximumselector, operation and block indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Prepared for microamperometer connection withionisation cable.
• Electrical protection rating IP40.
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
60 ÷ 340 SPARKGAS 30 LX 15145410 1N AC 60Hz 230V 0,37 560 275 102 900 140 ÷ 310 135 1010 x 640 x 390 45 3) 4)
60 ÷ 340 SPARKGAS 30 LX V 15145415 1N AC 60Hz 230V 0,37 670 275 102 900 140 ÷ 310 135 1030 x 730 x 610 45 3) 4)
60 ÷ 340 SPARKGAS 30 LX 15140010 1N AC 50Hz 230V 0,37 560 275 102 900 140 ÷ 310 135 1010 x 640 x 390 45 3) 4)
60 ÷ 340 SPARKGAS 30 LX V 15140015 1N AC 50Hz 230V 0,37 670 275 102 900 140 ÷ 310 135 1030 x 730 x 610 45 3) 4)
Frequency 50 Hz
Frequency 60 Hz
Natural gas
Part no. Description97980054 Soundproof burner cover for SPARKGAS 30 LX97980055 Soundproof burner cover for SPARKGAS 30 LX V
Accessories available on request
NEW
9999
SPARKGAS 30 LX and LX V from 60 to 340 kWGas train
Perdite di carico(testa di combustione + rampagas + regolazione di pressione)
SPARKGAS 30LX metanoCE / EXP
ediz.03/2003
0
5
10
15
20
25
30
35
40
45
50
0 50 100 150 200 250 300 350 400
PORTATA kW
PR
ES
SIO
NE
m
bar
24A
24B
24C
100 19990440 Included 96000005 — D3
24A360 19990447 Included 96000005 — D3
CTV 100 19990440 Included 96000005 98000100 D3 5)
SPARKGAS 30LX NATURALCE / EXP
CTV 360 19990447 Included 96000005 98000100 D3 5)
SPARKGAS 30LX V GAS24B
100 19990441 Included 96000004 — D3
CTV 100 19990441 Included 96000004 98000100 D3 5)
24C100 19990443 Included 96000013 — D3
CTV 100 19990443 Included 96000013 98000100 D3 5)
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
100100
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage progressive output operation.• Ability to operate with output modulation by
means of automatic RWF40 regulator mounted onthe control panel (to be ordered separately withthe modulation kit).
• Ability to operate with any type of combustionchamber.
• Air-gas mixing at blast-pipe.• Burnt gas recycling blast-pipe able to achieve
very low pollutant emissions, particularly withregard to nitrous oxides (NOx).
• Maintenance facilitated by the fact that the mixingunit can be removed without having to removethe burner from the boiler.
• Minimum and maximum air flow regulation forfirst and second stage by means of electricservomotor with pause closure of gate to preventany heat dispersion to flue.
• Fan speed adjustment in relation to changes inburner demand provided by means of inverter, toobtain a significant reduction in noise levels andelectricity consumption (version V only).
• Possibility to chose gas train with valve tightnesscontrol.
• Equipped with one flange and one insulating seal
for boiler fastening.CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan (with
electronic inverter control in version V).• Air pressure switch to ensure the presence of
combustion air.• Monoblock modulating gas train complete with
operation and safety valve, minimum pressureswitch, pressure regulator and gas filter.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by ionisation electrode.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximumselector, operation and block indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
Series BGN…LX and LX V from 60 to 1200 kWProgressive/modulating two-stage gas burners
C
F
D
A
0002
4708
41-T
B5B1
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
BGN 40 LX BGN 60 LX BGN 120 LX
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
mbar
100 200 300 400 500 600 700 800 900 1000 1100 1200 1300
0 10 20 30 40 50 60 70 80 90 100 110 120 130
kW
mn3/h Metano
4) Equipped with automatic device for air closing.5) Valve tightness control not required by EN676.CTV)Gas train with Valve Tightness Control.**) Maximum gas pressure at pressure regulator in CE version, at gas train for
EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Boiler coupling kit
Gas burner accessories
Modulating modeComplete the burner with the automatic RWF40 regulator and the modulation kit(see page 166).
Notes
LOWNOx
0085
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
60 ÷ 400 BGN 40 LX 15160010 3N AC 50Hz 400V 0,37 455 295 102 1080 140 ÷ 310 135 1260 x 660 x 680 70 4)
60 ÷ 400 BGN 40 LX V 15160015 1N AC 50Hz 230V 0,37 620 295 102 1080 140 ÷ 310 135 1260 x 660 x 680 70 4)
80 ÷ 720 BGN 60 LX 15180010 3N AC 50Hz 400V 1,1 540 365 120 1270 190 ÷ 380 160 1510 x 750 x 720 98 4)
80 ÷ 720 BGN 60 LX V 15180015 3N AC 50Hz 400V 1,1 525 365 120 1270 190 ÷ 380 160 1510 x 750 x 720 103 4)
150 ÷ 1200 BGN 120 LX 15220010 3N AC 50Hz 400V 2,2 630 450 137 1435 250 ÷ 410 195 1730 x 1030 x 880 165 4)
150 ÷ 1200 BGN 120 LX V 15220015 3N AC 50Hz 400V 2,2 620 450 137 1435 250 ÷ 410 195 1730 x 1030 x 880 170 4)
60 ÷ 400 BGN 40 LX 15165410 3N AC 60Hz 400V 0,55 455 295 102 1080 140 ÷ 310 135 1260 x 660 x 680 70 4)
60 ÷ 400 BGN 40 LX V 15165415 1N AC 50Hz 230V 0,37 620 295 102 1080 140 ÷ 310 135 1260 x 660 x 680 70 4)
80 ÷ 720 BGN 60 LX 15185410 3N AC 60Hz 400V 1,5 540 365 120 1270 190 ÷ 380 160 1510 x 750 x 720 98 4)
80 ÷ 720 BGN 60 LX V 15185415 3N AC 60Hz 400V 1,1 525 365 120 1270 190 ÷ 380 160 1510 x 750 x 720 103 4)
150 ÷ 1200 BGN 120 LX 15225410 3N AC 60Hz 400V 3,5 630 450 137 1435 250 ÷ 410 195 1730 x 1030 x 880 165 4)
150 ÷ 1200 BGN 120 LX V 15225415 3N AC 60Hz 400V 2,2 620 450 137 1435 250 ÷ 410 195 1730 x 1030 x 880 170 4)
Frequency 50 Hz
Frequency 60 Hz
Natural gas
Part no. Description97980054 Soundproof burner cover for BGN 40 LX97980055 Soundproof burner cover for BGN 40 LX V-BGN 60-120
Accessories available on request
NEW
101101
BGN 40 LX and LX V from 60 to 400 kW Gas train
Perdite di carico(testa di combustione + rampagas +regolatore di pressione)
BGN 40LX metanoCE / EXP
ediz.03/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
0 50 100 150 200 250 300 350 400 450
PORTATA kW
PR
ES
SIO
NE
m
bar
25A
25B
25C
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
100 19990440 Included 96000005 — D3
25A360 19990447 Included 96000005 — D3
CTV 100 19990440 Included 96000005 98000101 D3 5)
BGN 40LX NATURAL CE / EXP
CTV 360 19990447 Included 96000005 98000101 D3 5)
BGN 40LX V GAS25B
100 19990441 Included 96000004 — D3
CTV 100 19990441 Included 96000004 98000101 D3 5)
25C100 19990443 Included 96000013 — D3
CTV 100 19990443 Included 96000013 98000101 D3 5)
102102
BGN 60 LX and LX V from 80 to 720 kW Gas train
Perdite di carico(testa di combustione + rampagas +regolatore di pressione)
BGN 60LX metanoCE / EXP
ediz.03/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
0 10 20 30 40 50 60 70 80
PORTATA kW x10
PR
ES
SIO
NE
m
bar
26A
26C
26B
26D
26E
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
100 19990440 Included 96000014 — D3
26A360 19990447 Included 96000014 — D3
CTV 100 19990440 Included 96000014 98000101 D3 5)
CTV 360 19990447 Included 96000014 98000101 D3 5)
100 19990441 Included 96000032 — D3
26B360 19990448 Included 96000032 — D3
BGN 60LX NATURALCE / EXP
CTV 100 19990441 Included 96000032 98000101 D3 5)
BGN 60LX V GAS CTV 360 19990448 Included 96000032 98000101 D3 5)
26C100 19990442 Included 96000007 — D3
CTV 100 19990442 Included 96000007 98000101 D3 5)
26D100 19990443 Included — — D3
CTV 100 19990443 Included — 98000101 D3 5)
26E100 19990444 Included — — D3
CTV 100 19990444 Included — 98000101 D3 5)
103103
BGN 120 LX and LX V from 150 to 1200 kW Gas train
Perdite di carico(testa di combustione + rampagas + regolatore di pressione)
BGN 120LX metanoCE / EXP
ediz.03/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130
PORTATA kW x10
PR
ES
SIO
NE
m
bar
27A
27C
27B
27D
27E
100 19990441 Included 96000033 — D3
27A360 19990448 Included 96000033 — D3
CTV 100 19990441 Included 96000033 98000101 D3 5)
CTV 360 19990448 Included 96000033 98000101 D3 5)
27B100 19990442 Included 96000009 — D3
BGN 120LX NATURAL CE / EXP
CTV 100 19990442 Included 96000009 98000101 D3 5)
BGN 120LX V GAS27C
100 19990443 Included 96000010 — D3
CTV 100 19990443 Included 96000010 98000101 D3 5)
27D100 19990444 Included 96000010 — D3
CTV 100 19990444 Included 96000010 98000101 D3 5)
27E360 19990445 Included 96005007 — D3
CTV 360 19990445 Included 96005007 98000101 D3 5)
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
104104
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the controlpanel (to be ordered separately with the modulation kit).
• Ability to operate with any type of combustionchamber.
• Air-gas mixing at blast-pipe.• Burnt gas recycling blast-pipe able to achieve very
low pollutant emissions, particularly with regard tonitrous oxides (NOx).
• Maintenance facilitated by the fact that the mixingunit can be removed without having to remove theburner from the boiler.
• Minimum and maximum air flow regulation for firstand second stage by means of electric servomotorwith pause closure of gate to prevent any heatdispersion to flue.
• Fan speed adjustment in relation to changes in burnerdemand provided by means of inverter, to obtain asignificant reduction in noise levels and electricityconsumption (version V only).
• Valves tightness control compliant with Europeanstandard EN676 in the CE execution; on request inthe EXP execution.
• Equipped with one flange and one insulating seal forboiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle and
deflector disk in steel.• Three-phase electric motor to run fan (with electronic
inverter control in version V).• Air pressure switch to ensure the presence of
combustion air.• Monoblock modulating gas train complete with
operation and safety valve, valves seal control,minimum pressure switch, pressure regulator and gasfilter.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by ionisation electrode.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximum selector,operation and block indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control the secondstage of working or for the connection of theelectronic output regolator.
• Electrical protection rating IP40.
Series BGN…LX and LX V from 250 to 3950 kWProgressive/modulating two-stage gas burners
0123456789
10111213141516171819202122
50 100 150 200 250 300 350 400 450 500 550 600 650
0
kW x10
mbar
5 10 15 20 25 30 35 40 45 50 55 60 65mn3/h x 10
(Metano)
BGN 200 LX BGN 300 LX BGN 390 LX BGN 540 LX
C
F
D
A
0002
4708
41-T
B5B1
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
4) Equipped with automatic device for air closing.CTV)Gas train with Valve Tightness Control.**) Maximum gas pressure at pressure regulator in CE version, at gas train for
EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Boiler coupling kit
Gas burner accessories
Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
Notes
LOWNOx
0085
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
250 ÷ 2150 BGN 200 LX 15240010 3N AC 50Hz 400V 3 800 580 150 1740 280 ÷ 480 220 2030 x 1210 x 990 240 4)
250 ÷ 2150 BGN 200 LX V 15240015 3N AC 50Hz 400V 3 800 580 150 1740 280 ÷ 480 220 2030 x 1210 x 990 248 4)
400 ÷ 3600 BGN 300 LX 15260010 3N AC 50Hz 400V 7,5 845 580 177 1740 270 ÷ 450 275 2030 x 1210 x 990 305 4)
400 ÷ 3600 BGN 300 LX V 15260015 3N AC 50Hz 400V 7,5 845 580 177 1740 270 ÷ 450 275 2030 x 1210 x 990 317 4)
400 ÷ 3950 BGN 390 LX 15280010 3N AC 50Hz 400V 7,5 845 580 177 1740 270 ÷ 450 275 2030 x 1210 x 990 310 4)
400 ÷ 3950 BGN 390 LX V 15280015 3N AC 50Hz 400V 7,5 845 580 177 1740 270 ÷ 450 275 2030 x 1210 x 990 322 4)
250 ÷ 2150 BGN 200 LX 15245410 3N AC 60Hz 400V 3,5 800 580 150 1740 280 ÷ 480 220 2030 x 1210 x 990 240 4)
250 ÷ 2150 BGN 200 LX V 15245415 3N AC 60Hz 400V 3 800 580 150 1740 280 ÷ 480 220 2030 x 1210 x 990 248 4)
400 ÷ 3600 BGN 300 LX 15265410 3N AC 60Hz 400V 9 845 580 177 1740 270 ÷ 450 275 2030 x 1210 x 990 305 4)
400 ÷ 3600 BGN 300 LX V 15265415 3N AC 60Hz 400V 7,5 845 580 177 1740 270 ÷ 450 275 2030 x 1210 x 990 317 4)
400 ÷ 3950 BGN 390 LX 15285410 3N AC 60Hz 400V 9 845 580 177 1740 270 ÷ 450 275 2030 x 1210 x 990 310 4)
400 ÷ 3950 BGN 390 LX V 15285415 3N AC 60Hz 400V 7,5 845 580 177 1740 270 ÷ 450 275 2030 x 1210 x 990 322 4)
Frequency 50 Hz
Frequency 60 Hz
Natural gas
Part no. Description97980057 Soundproof burner cover
Accessories available on request
NEW
105105
BGN 200 LX and LX V from 250 to 2150 kWGas train
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 200LX metanoEXP
ediz.03/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
PORTATA kW x100
PR
ES
SIO
NE
m
bar
28J
28L
28K
28M
28N
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 200LX metanoCE
ediz.03/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
PORTATA kW x100
PR
ES
SIO
NE
m
bar
28A
28C
28B
28D
28E
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
100 19990442 Included 96000011 D3
28AComplete the gas train with the VPS.S02 kit part. no 98000101
360 19990449 Included 96000011 D3
Complete the gas train with the VPS.S02 kit part. no 98000101
100 19990443 Included 96000012 D3
28BComplete the gas train with the VPS.S02 kit part. no 98000101
CE 360 19990450 Included 96000012 D3
Complete the gas train with the VPS.S02 kit part. no 98000101
28C100 19990444 Included 96000012 D3
Complete the gas train with the VPS.S02 kit part. no 98000101
28D360 19990445 Included 96005004 D3
Complete the gas train with the VPS.S02 kit part. no 98000101
28E360 19990446 Included 96005004 D3
BGN 200LX NATURAL Complete the gas train with the VPS.S02 kit part. no 98000101
BGN 200LX V GAS 100 19990442 Included 96000011 — D3
28J360 19990449 Included 96000011 — D3
CTV 100 19990442 Included 96000011 98000101 D3
CTV 360 19990449 Included 96000011 98000101 D3
100 19990443 Included 96000012 — D3
28K360 19990450 Included 96000012 — D3
EXPCTV 100 19990443 Included 96000012 98000101 D3
CTV 360 19990450 Included 96000012 98000101 D3
28L100 19990444 Included 96000012 — D3
CTV 100 19990444 Included 96000012 98000101 D3
28M360 19990445 Included 96005004 — D3
CTV 360 19990445 Included 96005004 98000101 D3
28N360 19990446 Included 96005004 — D3
CTV 360 19990446 Included 96005004 98000101 D3
Head loss (combustion head + gas train+ pressure regulator)
Pres
sure
Thermal output
Natural gas Head loss (combustion head + gas train+ pressure regulator)
Pres
sure
Thermal output
Natural gas
106106
BGN 300 LX and LX V from 400 to 3600 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 300LX metanoCE
ediz.03/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
0 5 10 15 20 25 30 35 40
PORTATA kW x100
PR
ES
SIO
NE
m
bar
29C
29B
29D
29A
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 300LX metanoEXP
ediz.03/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
0 5 10 15 20 25 30 35 40
PORTATA kW x100
PR
ES
SIO
NE
m
bar
29L
29K
29M
29J
100 19990443 Included 96000012 D3
29AComplete the gas train with the VPS.S02 kit part. no 98000101
360 19990450 Included 96000012 D3
Complete the gas train with the VPS.S02 kit part. no 98000101
100 19990444 Included 96000012 D3
CE 29BComplete the gas train with the VPS.S02 kit part. no 98000101
360 19990451 Included 96000012 D3
Complete the gas train with the VPS.S02 kit part. no 98000101
29C360 19990445 Included 96005004 D3
Complete the gas train with the VPS.S02 kit part. no 98000101
29D360 19990446 Included 96005004 D3
BGN 300LX NATURAL Complete the gas train with the VPS.S02 kit part. no 98000101
BGN 300LX V GAS 100 19990443 Included 96000012 — D3
29J360 19990450 Included 96000012 — D3
CTV 100 19990443 Included 96000012 98000101 D3
CTV 360 19990450 Included 96000012 98000101 D3
100 19990444 Included 96000012 — D3
EXP 29K360 19990451 Included 96000012 — D3
CTV 100 19990444 Included 96000012 98000101 D3
CTV 360 19990451 Included 96000012 98000101 D3
29L360 19990445 Included 96005004 — D3
CTV 360 19990445 Included 96005004 98000101 D3
29M360 19990446 Included 96005004 — D3
CTV 360 19990446 Included 96005004 98000101 D3
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gas train+ pressure regulator)
Pres
sure
Thermal output
Natural gas Head loss (combustion head + gas train+ pressure regulator)
Pres
sure
Thermal output
Natural gas
107107
BGN 390 LX and LX V from 400 to 3950 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 390LX metanoCE
ediz.03/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
155
0 5 10 15 20 25 30 35 40 45
PORTATA kW x100
PR
ES
SIO
NE
m
bar
30C
30B
30A
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 390LX metanoEXP
ediz.03/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
155
0 5 10 15 20 25 30 35 40 45
PORTATA kW x100
PR
ES
SIO
NE
m
bar
30L
30K
30J
100 19990444 Included 96000012 D3
30AComplete the gas train with the VPS.S02 kit part. no 98000101
360 19990451 Included 96000012 D3
CEComplete the gas train with the VPS.S02 kit part. no 98000101
30B360 19990445 Included 96005004 D3
Complete the gas train with the VPS.S02 kit part. no 98000101
30C360 19990446 Included 96005004 D3
BGN 390LX NATURAL Complete the gas train with the VPS.S02 kit part. no 98000101
BGN 390LX V GAS 100 19990444 Included 96000012 — D3
30J360 19990451 Included 96000012 — D3
CTV 100 19990444 Included 96000012 98000101 D3
EXPCTV 360 19990451 Included 96000012 98000101 D3
30K360 19990445 Included 96005004 — D3
CTV 360 19990445 Included 96005004 98000101 D3
30L360 19990446 Included 96005004 — D3
CTV 360 19990446 Included 96005004 98000101 D3
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gas train+ pressure regulator)
Pres
sure
Thermal output
Natural gas Head loss (combustion head + gas train+ pressure regulator)
Pres
sure
Thermal output
Natural gas
108108
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage progressive output operation.• Ability to operate with output modulation by
means of automatic RWF40 regulator mounted onthe control panel (to be ordered separately withthe modulation kit).
• Ability to operate with any type of combustionchamber.
• Air-gas mixing at blast-pipe.• Burnt gas recycling blast-pipe able to achieve
very low pollutant emissions, particularly withregard to nitrous oxides (NOx).
• Maintenance facilitated by the fact that the mixingunit can be removed without having to removethe burner from the boiler.
• Minimum and maximum air flow regulation forfirst and second stage by means of electricservomotor with pause closure of gate to preventany heat dispersion to flue.
• Fan speed adjustment in relation to changes inburner demand provided by means of inverter, toobtain a significant reduction in noise levels andelectricity consumption (version V only).
• Valves tightness control compliant with Europeanstandard EN676 in the CE execution; on requestin the EXP execution.
• Equipped with one flange and one insulating sealfor boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan (with
electronic inverter control in version V).• Air pressure switch to ensure the presence of
combustion air.• Monoblock modulating gas train complete with
operation and safety valve, valves seal control,minimum pressure switch, pressure regulator andgas filter.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by UV photo-electronic cell.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximumselector, operation and block indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
BGN 540 LX and LX V from 600 to 5900 kWProgressive/modulating two-stage gas burners
0123456789
10111213141516171819202122
50 100 150 200 250 300 350 400 450 500 550 600 650
0
kW x10
mbar
5 10 15 20 25 30 35 40 45 50 55 60 65mn3/h x 10
(Metano)
BGN 200 LX BGN 300 LX BGN 390 LX BGN 540 LX
C
F
D
A
0002
4708
41-T
B5B1
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
4) Equipped with automatic device for air closing.CTV)Gas train with Valve Tightness Control. Please add the relevant kit.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Boiler coupling kit
Gas burner accessories
Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
Notes
LOWNOx
0085
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
600 ÷ 5900 BGN 540 LX 15320010 3N AC 50Hz 400V 15 1154 695 283 2110 330 ÷ 600 355 2260 x 1520 x 1200 518 4)
600 ÷ 5900 BGN 540 LX V 15320015 3N AC 50Hz 400V 15 1154 695 283 2110 330 ÷ 600 355 2260 x 1520 x 1200 541 4)
600 ÷ 5900 BGN 540 LX 15325410 3N AC 60Hz 400V 22 1154 695 283 2110 330 ÷ 600 355 2260 x 1520 x 1200 518 4)
600 ÷ 5900 BGN 540 LX V 15325415 3N AC 60Hz 400V 15 1154 695 283 2110 330 ÷ 600 355 2260 x 1520 x 1200 541 4)
Frequency 50 Hz
Frequency 60 Hz
Natural gas
NEW
109109
BGN 540 LX and LX V from 600 to 5900 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 540LX metanoCE
ediz.03/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
155
160
0 5 10 15 20 25 30 35 40 45 50 55 60 65
PORTATA kW x100
PR
ES
SIO
NE
m
bar
31B
31A
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 540LX metanoEXP
ediz.03/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
155
160
0 5 10 15 20 25 30 35 40 45 50 55 60 65
PORTATA kW x100
PR
ES
SIO
NE
m
bar
31K
31J
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
31A360 19990452 Included — D3
CEComplete the gas train with the VPS.S02 kit part. no 98000101
31B360 19990453 Included — D3
BGN 540LX NATURAL Complete the gas train with the VPS.S02 kit part. no 98000101
BGN 540LX V GAS31J
360 19990452 Included — — D3
EXPCTV 360 19990452 Included — 98000101 D3
31K360 19990453 Included — — D3
CTV 360 19990453 Included — 98000101 D3
110110110
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage progressive output operation.• Ability to operate with output modulation by
means of automatic RWF40 regulator mounted onthe control panel (to be ordered separately withthe modulation kit).
• Ability to operate with any type of combustionchamber.
• Air-gas mixing at blast-pipe.• Burnt gas recycling blast-pipe able to achieve
very low pollutant emissions, particularly withregard to nitrous oxides (NOx).
• Maintenance facilitated by the fact that the mixingunit can be removed without having to removethe burner from the boiler.
• Minimum and maximum air flow regulation forfirst and second stage by means of electricservomotor with pause closure of gate to preventany heat dispersion to flue.
• Fan speed adjustment in relation to changes inburner demand provided by means of inverter, toobtain a significant reduction in noise levels andelectricity consumption (version V only).
• Valves tightness control compliant with Europeanstandard EN676 in the CE execution; on requestin the EXP execution.
• Equipped with one insulating seal for boilerfastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Steel fan part.• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Boiler coupling flange with hinge to facilitate
dismantling of deflector disk.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan (with
electronic inverter control in version V).• Air pressure switch to ensure the presence of
combustion air.• Monoblock modulating gas train complete with
operation and safety valve, valves seal control,minimum pressure switch, pressure regulator andgas filter.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by UV photo-electronic cell.• Synoptic control panel with Stop/Go switch,
automatic/manual and mininum/maximum selectorand operation block indicators.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
GI 1000 LX and LX V from 1500 to 10850 kWProgressive/modulating two-stage gas burners
30
11100
25
1098
20
15
mbar
10
5
kWx1000765432
0002
9224
20-T
GI 1000 LX
B
C
A
D
E
0002
6706
10-T
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
4) Equipped with automatic device for air closing.CTV)Gas train with Valve Tightness Control. Please add the relevant kit.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Boiler coupling kit
Gas burner accessories
Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
Notes
LOWNOx
0085
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Frequency 50 Hz
Natural gas
1500 ÷ 10850 GI 1000 LX 15360010 3N AC 50Hz 400V 22 1235 1205 - 2350 600 486 2260 x 1710 x 1500 640 4)
1500 ÷ 10850 GI 1000 LX V 15360015 3N AC 50Hz 400V 22 1235 1205 - 2350 600 486 2260 x 1710 x 1500 673 4)
NEW
111111111
GI 1000 LX and LX V from 1500 to 10850 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
GI 1000LX metanoCE
ediz.01/2004
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
0 10 20 30 40 50 60 70 80 90 100 110 120
PORTATA kW x100
PR
ES
SIO
NE
m
bar
42C
42B
42A
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
GI 1000LX metanoEXP
ediz.01/2004
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
0 10 20 30 40 50 60 70 80 90 100 110 120
PORTATA kW x100
PR
ES
SIO
NE
m
bar
42L
42K
42J
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output Thermal output
Natural gas Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Natural gas
42A500 19990468 Included — D3
Complete the gas train with the VPS.S02 kit part. no 98000101
CE 42B500 19990469 Included — D3
Complete the gas train with the VPS.S02 kit part. no 98000101
42C500 19990470 Included — D3
GI 1000LX NATURAL Complete the gas train with the VPS.S02 kit part. no 98000101
GI 1000LX V GAS42J
500 19990468 Included — — D3
EXPCTV 500 19990468 Included — 98000101 D3
42K500 19990469 Included — — D3
CTV 500 19990469 Included — 98000101 D3
42L500 19990470 Included — — D3
CTV 500 19990470 Included — 98000101 D3
112
Series BGN…DSPGN ME from 185 to 738 kW Progressive/modulating two-stage gas burners
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the controlpanel (to be ordered separately with the modulation kit).
• Ability to operate with any type of combustion chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Minimum/maximum air flow adjustment by meansof electric servo step motor with air gate closurein pause to avoid heat loss to flue.
• With valve tightness control.• Equipped with one flange and one insulating seal
for boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Electric servo step motors for simultaneous control of
combustion air and fuel. • In the CE version gas train complete with control,
operating and safety valve, valve tightnesscontrol, minimum and maximum pressure switch,pressure regulator and gas filter; in the EXPORTversion gas train complete with control, operatingand safety valve, valve tightness control, minimumand maximum pressure switch.
• Burner automatic command and control equipmentwith microprocessor (electronic cam) in compliancewith European standard EN298, with valve tightnesscontrol and eBus connection. Display for operatingsequence, modulation percentage, and error code inthe event of a lockout.
• Flame detection by ionisation electrode.• Control panel with burner Stop/Go switch,
automatic/manual and minimum/maximumselector operation and block indicators.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
Conformi alla:Direttiva gas 90/396/CEE
Direttiva E.M.C. 89/336/CEEDirettiva L.V. 73/23/CEE
Norma di riferimento: EN676
185 ÷ 425 BGN 40 DSPGN ME 16070050 3N AC 50Hz 400V 0,37 470 295 102 1100 150 ÷ 330 135 1260 x 660 x 680 63 4)
248 ÷ 738 BGN 60 DSPGN ME 16520050 3N AC 50Hz 400V 1,1 560 365 120 1270 170 ÷ 400 160 1510 x 750 x 720 88 4)
Frequency 50 Hz
Frequency 60 Hz
185 ÷ 425 BGN 40 DSPGN ME 16075410 3N AC 60Hz 400V 0,55 470 295 102 1100 150 ÷ 330 135 1260 x 660 x 680 63 4)
248 ÷ 738 BGN 60 DSPGN ME 16525410 3N AC 60Hz 400V 1,5 560 365 120 1270 170 ÷ 400 160 1510 x 750 x 720 88 4)
0085
0002
4705
81/2
-T B1B5
4) Equipped with automatic device for air closing.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Boiler coupling kit
Gas burner accessories
Notes
Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
NEW ElectrElectroniconic
modulation modulation
3
3
BGN120PBGN100PBGN60PBGN40PBGN120DSPGN
504846
130120
13001200kW
n
n
m /h G.P.L.
m /h Metano
444240383634323028262422201816141210864
1101009080706050403020
11001000900800700600500400300200
10
100
0002
9222
81-T
BGN60DSPGNBGN40DSPGN BGN100DSPGNBGN120DSPGN MEBGN60DSPGN MEBGN40DSPGN ME BGN100DSPGN ME
mbar14
12
10
0
8
6
4
2
Natural gas
LPG
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
LPG version available: please contact sales office for quot.
113
Series BGN…DSPGN ME from 185 to 738 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 40DSPGN ME metanoCE / EXP
ediz.11/2004
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
150 175 200 225 250 275 300 325 350 375 400 425 450
PORTATA [kW]
PR
ES
SIO
NE
[
mb
ar]
52C
52B
52A
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphVersionGas
type
52A 360 19990500 Included – D2
BGN 40 DSPGN ME NATURAL CE / EXP 52B 360 19990501 Included – D2
52C 360 19990502 Included – D2
53A 360 19990500 Included 96000007 D2
53B 360 19990501 Included 96000007 D2
BGN 60 DSPGN ME NATURAL CE / EXP 53C 360 19990502 Included 96000007 D2
53D 360 19990503 Included – D2
53E 500 19990504 Included 96000034 D2
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 60DSPGN ME metanoCE / EXP
ediz.11/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
65
200 250 300 350 400 450 500 550 600 650 700 750 800
PORTATA [kW]
PR
ES
SIO
NE
[
mb
ar]
53C
53E
53B
53A
53D
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
114
Series BGN…DSPGN ME from 280 to 1200 kWProgressive/modulating two-stage gas burners
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the controlpanel (to be ordered separately with the modulation kit).
• Ability to operate with any type of combustion chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Minimum/maximum air flow adjustment by meansof electric servo step motor with air gate closurein pause to avoid heat loss to flue.
• With valve tightness control.• Equipped with one flange and one insulating seal
for boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Servomotori elettrici passo-passo per la regolazione
contemporanea dell'aria comburente e del combustibile.• In the CE version gas train complete with control,
operating and safety valve, valve tightnesscontrol, minimum and maximum pressure switch,pressure regulator and gas filter; in the EXPORTversion gas train complete with control, operatingand safety valve, valve tightness control, minimumand maximum pressure switch.
• Burner automatic command and controlequipment with microprocessor (electronic cam) incompliance with European standard EN298, withvalve tightness control and eBus connection.Display for operating sequence, modulationpercentage, and error code in the event of alockout.
• Flame detection by ionisation electrode.• Control panel with burner Stop/Go switch,
automatic/manual and minimum/maximumselector operation and block indicators.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
Conformi alla:Direttiva gas 90/396/CEE
Direttiva E.M.C. 89/336/CEEDirettiva L.V. 73/23/CEE
Norma di riferimento: EN676
Frequency 50 Hz
Frequency 60 Hz
280 ÷ 995 BGN 100 DSPGN ME 16570050 3N AC 50Hz 400V 1,1 560 365 120 1330 240 ÷ 460 160 1510 x 750 x 720 91 4)
350 ÷ 1200 BGN 120 DSPGN ME 16620050 3N AC 50Hz 400V 1,5 590 365 137 1400 220 ÷ 440 195 1510 x 750 x 720 100 4)
280 ÷ 995 BGN 100 DSPGN ME 16575410 3N AC 60Hz 400V 1,5 560 365 120 1330 240 ÷ 460 160 1510 x 750 x 720 91 4)
350 ÷ 1200 BGN 120 DSPGN ME 16625410 3N AC 60Hz 400V 2,6 590 365 137 1400 220 ÷ 440 195 1510 x 750 x 720 100 4)
0085
NEW ElectrElectroniconic
modulation modulation
0002
4705
81/2
-T B1B5
Notes
Boiler coupling kit
Gas burner accessories
Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
4) Equipped with automatic device for air closing.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
3
3
BGN120PBGN100PBGN60PBGN40PBGN120DSPGN
504846
130120
13001200kW
n
n
m /h G.P.L.
m /h Metano
444240383634323028262422201816141210864
1101009080706050403020
11001000900800700600500400300200
10
100
0002
9222
81-T
BGN60DSPGNBGN40DSPGN BGN100DSPGNBGN120DSPGN MEBGN60DSPGN MEBGN40DSPGN ME BGN100DSPGN ME
mbar14
12
10
0
8
6
4
2
Natural gas
LPG
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
LPG version available: please contact sales office for quot.
115
Series BGN…DSPGN ME from 280 to 1200 kWGas train
For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 120DSPGN ME metanoCE / EXP
ediz.11/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
20 30 40 50 60 70 80 90 100 110 120 130
PORTATA [kW x10]
PR
ES
SIO
NE
[
mb
ar]
55C
55E
55B
55A
55D
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
54A 360 19990500 Included 96000007 D2
54B 360 19990501 Included 96000007 D2
BGN 100 DSPGN ME NATURAL CE / EXP 54C 360 19990502 Included 96000007 D2
54D 360 19990503 Included – D2
54E 500 19990504 Included 96000034 D2
55A 360 19990501 Included 96000009 D2
55B 360 19990502 Included 96000009 D2
BGN 120 DSPGN ME NATURAL CE / EXP 55C 360 19990503 Included 96000010 D2
55D 500 19990504 Included 96000010 D2
55E 500 19990505 Included 96005002 D2
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 100DSPGN ME metanoCE / EXP
ediz.11/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
20 30 40 50 60 70 80 90 100 110
PORTATA [kW x10]
PR
ES
SIO
NE
[
mb
ar]
54C
54E
54B
54A
54D
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphVersionGas
type
116
Series BGN…DSPGN ME from 414 to 2000 kWProgressive/modulating two-stage gas burners
Conformi alla:Direttiva gas 90/396/CEE
Direttiva E.M.C. 89/336/CEEDirettiva L.V. 73/23/CEE
Norma di riferimento: EN676
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the control panel(to be ordered separately with the modulation kit).
• Ability to operate with any type of combustion chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to remove theburner from the boiler.
• Minimum/maximum air flow adjustment by meansof electric servo step motor with air gate closure inpause to avoid heat loss to flue.
• Valves tightness control device compliant withEuropean standard EN676.
• Equipped with one flange and one insulating sealfor boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan.• Air pressure switch to ensure the presence of combustion air.• Electric servo step motors for simultaneous control of
combustion air and fuel. • In the CE version gas train complete with control,
operating and safety valve, valve tightness control,minimum and maximum pressure switch, pressureregulator and gas filter; in the EXPORT version gas traincomplete with control, operating and safety valve, valvetightness control, minimum and maximum pressure switch.
• Burner automatic command and control equipmentwith microprocessor (electronic cam) in compliancewith European standard EN298, with valve tightnesscontrol and eBus connection. Display for operatingsequence, modulation percentage, and error code inthe event of a lockout.
• Flame detection by ionisation electrode.• Control panel with burner Stop/Go switch,
automatic/manual and minimum/maximumselector operation and block indicators.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
Frequency 50 Hz
Frequency 60 Hz
414 ÷ 1428 BGN 150 DSPGN ME 16670050 3N AC 50Hz 400V 2,2 655 450 137 1500 220 ÷ 440 195 1730 x 1030 x 880 148 4)
590 ÷ 2000 BGN 200 DSPGN ME 16720050 3N AC 50Hz 400V 3 830 580 150 1850 300 ÷ 600 220 2030 x 1210 x 990 220 4)
414 ÷ 1428 BGN 150 DSPGN ME 16675410 3N AC 60Hz 400V 3,4 655 450 137 1500 220 ÷ 440 195 1730 x 1030 x 880 148 4)
590 ÷ 2000 BGN 200 DSPGN ME 16725410 3N AC 60Hz 400V 3,5 830 580 150 1850 300 ÷ 600 220 2030 x 1210 x 990 220 4)
0085
NEW ElectrElectroniconic
modulation modulation
0002
4705
81/2
-T B1B5
BGN 150 DSPGN
BGN 200 DSPGN BGN 250 DSPGN
BGN 300 DSPGNBGN 150 DSPGN ME BGN 300 DSPGN ME
BGN 350 DSPGNBGN 200 DSPGN ME BGN 250 DSPGN ME BGN 350 DSPGN ME
mn3/h
mn3/h
kW(Metano)
(G.P.L.)40 80 120 160 200 240 280
400 800 1200 1600 2000 2400 2800 3200
320 360 400
3600 4000
10 20 30 40 50 60 70 110 120 130 140 1501009080
17.5
15
12.5
10
20
7.5
5
2.5
0
mbar
BT76
05_5
/1-T
4) Equipped with automatic device for air closing.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Boiler coupling kit
Gas burner accessories
Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
Notes
Natural gas
LPG
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
LPG version available: please contact sales office for quot.
117
Series BGN…DSPGN ME from 414 to 2000 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 200DSPGN ME metanoCE / EXP
ediz.11/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
0 5 10 15 20 25
PORTATA [kW x100]
PR
ES
SIO
NE
[
mb
ar]
57C
57B
57A
57D
57E
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gasPerdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 150DSPGN ME metanoCE / EXP
ediz.11/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
30 40 50 60 70 80 90 100 110 120 130 140 150 160
PORTATA [kW x10]
PR
ES
SIO
NE
[
mb
ar]
56C
56B
56A
56D
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
56A 360 19990502 Included 96000009 D2
56B 360 19990503 Included 96000010 D2BGN 150 DSPGN ME NATURAL CE / EXP
56C 500 19990504 Included 96000010 D2
56D 500 19990505 Included 96005002 D2
57A 360 19990502 Included 96000011 D2
57B 360 19990503 Included 96000012 D2
BGN 200 DSPGN ME NATURAL CE / EXP 57C 500 19990504 Included 96000012 D2
57D 500 19990505 Included 96005003 D2
57E 500 19990506 Included 96005004 D2
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphVersionGas
type
118
Series BGN…DSPGN ME from 490 to 2982 kWProgressive/modulating two-stage gas burners
Conformi alla:Direttiva gas 90/396/CEE
Direttiva E.M.C. 89/336/CEEDirettiva L.V. 73/23/CEE
Norma di riferimento: EN676
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the controlpanel (to be ordered separately with the modulation kit).
• Ability to operate with any type of combustion chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Minimum/maximum air flow adjustment by meansof electric servo step motor with air gate closurein pause to avoid heat loss to flue.
• Valves tightness control device compliant withEuropean standard EN676.
• Equipped with one flange and one insulating sealfor boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan.• Air pressure switch to ensure the presence of combustion air.• Electric servo step motors for simultaneous control of
combustion air and fuel. • In the CE version gas train complete with control,
operating and safety valve, valve tightness control,minimum and maximum pressure switch, pressureregulator and gas filter; in the EXPORT version gas traincomplete with control, operating and safety valve, valvetightness control, minimum and maximum pressure switch.
• Burner automatic command and control equipmentwith microprocessor (electronic cam) in compliancewith European standard EN298, with valve tightnesscontrol and eBus connection. Display for operatingsequence, modulation percentage, and error code inthe event of a lockout.
• Flame detection by ionisation electrode.• Control panel with burner Stop/Go switch,
automatic/manual and minimum/maximumselector operation and block indicators.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
Frequency 50 Hz
Frequency 60 Hz
490 ÷ 2500 BGN 250 DSPGN ME 16770050 3N AC 50Hz 400V 7,5 875 580 150 1850 300 ÷ 600 220 2030 x 1210 x 990 249 4)
657 ÷ 2982 BGN 300 DSPGN ME 16820050 3N AC 50Hz 400V 7,5 875 580 177 1850 275 ÷ 465 275 2030 x 1210 x 990 286 4)
490 ÷ 2500 BGN 250 DSPGN ME 16775410 3N AC 60Hz 400V 9 875 580 150 1850 300 ÷ 600 220 2030 x 1210 x 990 249 4)
657 ÷ 2982 BGN 300 DSPGN ME 16825410 3N AC 60Hz 400V 9 875 580 177 1850 275 ÷ 465 275 2030 x 1210 x 990 286 4)
0085
NEW ElectrElectroniconic
modulation modulation
0002
4705
81/2
-T B1B5
4) Equipped with automatic device for air closing.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Notes
Boiler coupling kit
Gas burner accessories
Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
LPG version available: please contact sales office for quot.
BGN 150 DSPGN
BGN 200 DSPGN BGN 250 DSPGN
BGN 300 DSPGNBGN 150 DSPGN ME BGN 300 DSPGN ME
BGN 350 DSPGNBGN 200 DSPGN ME BGN 250 DSPGN ME BGN 350 DSPGN ME
mn3/h
mn3/h
kW(Metano)
(G.P.L.)40 80 120 160 200 240 280
400 800 1200 1600 2000 2400 2800 3200
320 360 400
3600 4000
10 20 30 40 50 60 70 110 120 130 140 1501009080
17.5
15
12.5
10
20
7.5
5
2.5
0
mbar
BT76
05_5
/1-T
Natural gas
LPG
119
Series BGN…DSPGN ME from 490 to 2982 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 300DSPGN ME metanoCE / EXP
ediz.11/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
0 5 10 15 20 25 30 35
PORTATA [kW x100]
PR
ES
SIO
NE
[
mb
ar]
59C
59B
59A
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gasPerdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 250DSPGN ME metanoCE / EXP
ediz.11/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
0 5 10 15 20 25 30
PORTATA [kW x100]
PR
ES
SIO
NE
[
mb
ar]
58C
58B
58A
58D
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
58A 360 19990503 Included 96000012 D2
58B 500 19990504 Included 96000012 D2BGN 250 DSPGN ME NATURAL CE / EXP
58C 500 19990505 Included 96005003 D2
58D 500 19990506 Included 96005004 D2
59A 500 19990504 Included 96000012 D2
BGN 300 DSPGN ME NATURAL CE / EXP 59B 500 19990505 Included 96005003 D2
59C 500 19990506 Included 96005004 D2
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphVersionGas
type
120120
BGN 350 DSPGN ME from 924 to 3500 kWProgressive/modulating two-stage gas burners
Conformi alla:Direttiva gas 90/396/CEE
Direttiva E.M.C. 89/336/CEEDirettiva L.V. 73/23/CEE
Norma di riferimento: EN676
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the controlpanel (to be ordered separately with the modulation kit).
• Ability to operate with any type of combustion chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Minimum/maximum air flow adjustment by meansof electric servo step motor with air gate closurein pause to avoid heat loss to flue.
• Valves tightness control device compliant withEuropean standard EN676.
• Equipped with one flange and one insulating sealfor boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan.• Air pressure switch to ensure the presence of combustion air.• Electric servo step motors for simultaneous control of
combustion air and fuel. • In the CE version gas train complete with control,
operating and safety valve, valve tightness control,minimum and maximum pressure switch, pressureregulator and gas filter; in the EXPORT version gas traincomplete with control, operating and safety valve, valvetightness control, minimum and maximum pressure switch.
• Burner automatic command and control equipmentwith microprocessor (electronic cam) in compliancewith European standard EN298, with valve tightnesscontrol and eBus connection. Display for operatingsequence, modulation percentage, and error code inthe event of a lockout.
• Flame detection by ionisation electrode.• Control panel with burner Stop/Go switch,
automatic/manual and minimum/maximumselector operation and block indicators.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
Frequency 50 Hz
Frequency 60 Hz
0085
NEW ElectrElectroniconic
modulation modulation
4) Equipped with automatic device for air closing.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Notes
Boiler coupling kit
Gas burner accessories
Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
924 ÷ 3500 BGN 350 DSPGN ME 16870050 3N AC 50Hz 400V 7,5 880 580 177 1850 275 ÷ 465 275 2030 x 1210 x 990 290 4)
924 ÷ 3500 BGN 350 DSPGN ME 16875410 3N AC 60Hz 400V 9 880 580 177 1850 275 ÷ 465 275 2030 x 1210 x 990 290 4)
Amm
B 5mm
B 1mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
0002
4705
81/2
-T B1B5
LPG version available: please contact sales office for quot.
BGN 150 DSPGN
BGN 200 DSPGN BGN 250 DSPGN
BGN 300 DSPGNBGN 150 DSPGN ME BGN 300 DSPGN ME
BGN 350 DSPGNBGN 200 DSPGN ME BGN 250 DSPGN ME BGN 350 DSPGN ME
mn3/h
mn3/h
kW(Metano)
(G.P.L.)40 80 120 160 200 240 280
400 800 1200 1600 2000 2400 2800 3200
320 360 400
3600 4000
10 20 30 40 50 60 70 110 120 130 140 1501009080
17.5
15
12.5
10
20
7.5
5
2.5
0
mbar
BT76
05_5
/1-T
Natural gas
LPG
121121
BGN 350 DSPGN ME from 924 to 3500 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
BGN 350DSPGN ME metanoCE / EXP
ediz.11/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
5 10 15 20 25 30 35 40
PORTATA [kW x100]
PR
ES
SIO
NE
[
mb
ar]
60C
60B
60A
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Natural gas
For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
60A 500 19990504 Included 96000012 D2
BGN 350 DSPGN ME NATURAL CE / EXP 60B 500 19990505 Included 96005003 D2
60C 500 19990506 Included 96005004 D2
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphVersionGas
type
122
Series GI…DSPGN ME from 1188 to 6500 kWProgressive/modulating two-stage gas burners
Conformi alla:Direttiva gas 90/396/CEE
Direttiva E.M.C. 89/336/CEEDirettiva L.V. 73/23/CEE
Norma di riferimento: EN676
Thermaloutput
kWElectrical supply
Motor kW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Gastype
P.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
CE version - Frequency 50 Hz
Export version - Frequency 50 Hz
Export version - Frequency 60 Hz
1188 ÷ 4752 GI 350 ME 66480010 N.G. 200 97390074 D4 3N AC 50Hz 400V 15 2260 x 1520 x 1200 550 4)
1300 ÷ 6500 GI 510 ME 66540010 N.G. 200 97390083 D4 3N AC 50Hz 400V 18,5 2260 x 1520 x 1200 565 4)
1188 ÷ 4752 GI 350 ME 66480010 N.G. 200 - DE4 3N AC 50Hz 400V 15 2260 x 1520 x 1200 550 4)
1300 ÷ 6500 GI 510 ME 66540010 N.G. 150 - DE4 3N AC 50Hz 400V 18,5 2260 x 1520 x 1200 565 4)
1188 ÷ 4752 GI 350 ME 66485410 N.G. 200 - DE4 3N AC 60Hz 400V 11 2260 x 1520 x 1200 550 4)
1300 ÷ 6500 GI 510 ME 66545410 N.G. 150 - DE4 3N AC 60Hz 400V 22 2260 x 1520 x 1200 565 4)
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Power modulation operation by means of electronic
regulator integrated in the burner controlequipment (order specific modulation kit).
• Ability to operate with any type of combustion chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Minimum/maximum air flow adjustment by meansof electric servo step motor with air gate closurein pause to avoid heat loss to flue.
• Valves tightness control device compliant withEuropean standard EN676.
• Equipped with one flange and one insulating sealfor boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.
• Adjustable blast-pipe with stainless steel nozzleand deflector disk in steel.
• Three-phase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Electric servo step motors for simultaneous control of
combustion air and fuel. • In the CE version gas train complete with control,
operating and safety valve, valve tightnesscontrol, minimum and maximum pressure switch,pressure regulator and gas filter; in the EXPORTversion gas train complete with control, operatingand safety valve, valve tightness control, minimumand maximum pressure switch.
• Burner automatic command and control equipmentwith microprocessor (electronic cam) in compliancewith European standard EN298, with valve tightnesscontrol and electronic power regulator, equipped withMOD Bus connection. Display for operatingsequence, modulation percentage, and error code inthe event of a lockout.
• Flame detection by UV photo-electronic cell.• Control panel with burner Stop/Go switch,
automatic/manual and minimum/maximumselector operation and block indicators.
• Terminal block for electrical and thermostaticconnections to the burner.
• Electrical protection rating IP40.
0085
NEW ElectrElectroniconic
modulation modulation
Gas train is included already; to check if the gas train is suitable for the application, it is necessary to subtract the boiler backpressu-re from the mains gas pressure and select, in the P.Gas column, the value lower than this difference, to which there will correspond acorrect gas train with relative regulator and any adapter. If the difference between mains gas pressure and backpressure is lowerthan the value expressed in the P.Gas column, contact the Sales Office to arrange a non-standard set-up.
Amm
Bmm
Cmm
Dmm
FmmModel
0002
4705
81/3
-T
GI 350 ME 1160 1585 1970 230 ÷ 600 325
GI 510 ME 1175 1540 2030 320 ÷ 625 355
4) Equipped with automatic device for air closing.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Notes
Boiler coupling kit
Gas burner accessories
For information on the structure, composition, and size of the gas train pleaserefer to the diagrams on page 170.
To complete the burnermodulation kit (see page 166).
30
0
25
20
15
mbar
10
5
0
0002
9212
92-T
1 8kWx1000
765432
8007006005004003002001003m n/h Metano
GI 420 DSPGNGI 510 DSPGN
GI 350 DSPGN ME GI 510 DSPGN MEGI 350 DSPGN
Natural gas
123
GI 1000 LX ME from 1500 to 10850 kW Progressive/modulating two-stage gas burners
30
11100
25
1098
20
15
mbar
10
5
kWx1000765432
0002
9224
20-T
GI 1000 LX
B
C
A
D
E
0002
6706
10-T
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN676
4) Equipped with automatic device for air closing.9) On the main gas train regulator and filter are supplied separately; on the pilot
flame gas train the filter is incorporated in the regulator. All components mustbe ordered.
*) Minimum gas train inlet pressure needed to obtain maximum burner powerwith a combustion chamber backpressure of zero.
Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Boiler coupling kit
Gas burner accessories
Notes
Amm
Bmm
Cmm
Dmm
Emm
GI 1000 LX ME 1235 1205 2350 600 486
ModelGas train is included already; to check if the gas train is suitable for the application, it is necessary to subtract the boiler backpressu-re from the mains gas pressure and select, in the P.Gas column, the value lower than this difference, to which there will correspond acorrect gas train with relative regulator and any adapter. If the difference between mains gas pressure and backpressure is lowerthan the value expressed in the P.Gas column, contact the Sales Office to arrange a non-standard set-up.
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Gastype
P.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
1500 ÷ 10850 GI 1000 LX ME 66570010 N.G. 220 Included D4 3N AC 50Hz 400V 22 2600 x 1710 x 1500 925 4) 9)
For information on the structure, composition, and size of the gas train pleaserefer to the diagrams on page 170.
CE Version - Frequency 50 Hz
Export Version - Frequency 50 Hz1500 ÷ 10850 GI 1000 LX ME 66570010 N.G. 220 Included D4 3N AC 50Hz 400V 22 2600 x 1710 x 1500 925 4) 9)
LOWNOx
To complete the burnermodulation kit (see page 166).
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Power modulation operation by means of electronic
regulator integrated in the burner control equipment(order specific modulation kit).
• Ability to operate with any type of combustionchamber.
• Air-gas mixing at blast-pipe.• Burnt gas recycling blast-pipe able to achieve very
low pollutant emissions, particularly with regard tonitrous oxides (NOx).
• Maintenance facilitated by the fact that the mixingunit can be removed without having to remove theburner from the boiler.
• Minimum/maximum air flow adjustment by meansof electric servo step motor with air gate closure inpause to avoid heat loss to flue.
• Valves tightness control compliant with Europeanstandard EN676.
• Equipped with one insulating seal for boilerfastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Steel fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.
• Boiler coupling flange with hinge to facilitatedismantling of the atomising unit and deflectordisk.
• Adjustable blast-pipe with stainless steel nozzleand deflector disk in steel.
• Three-phase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Electric servo step motors for simultaneous control of
combustion air and fuel. • Monoblock modulating gas train complete with
operation and safety valve, valves seal control,minimum pressure switch, pressure regulator andgas filter.
• Burner automatic command and control equipmentwith microprocessor (electronic cam) in compliancewith European standard EN298, with valve tightnesscontrol and electronic power regulator, equippedwith MOD Bus connection. Display for operatingsequence, modulation percentage, and error codein the event of a lockout.
• Flame detection by UV photo-electronic cell.• Control panel with burner Stop/Go and Off
operation and block indicators.• Terminal block for the electrical and thermostatic
connections to the burner.• Electrical protection rating IP40.
NEW ElectrElectroniconic
modulation modulation
124124
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the controlpanel (to be ordered separately with the modulation kit).
• Ability to operate with any type of combustion chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Minimum and maximum air flow regulation for first andsecond stage by means of electric servomotor with pauseclosure of gate to prevent any heat dispersion to flue.
• A valve tightness control can be fitted on theburner.
• Equipped with one flange and one insulating sealfor boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.
• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• In the CE version the gas train is complete with regulator,
operating, safety and pilot valves, minimum pressureswitch, pressure regulator and gas filter; in the EXPORTversion the gas train is complete with regulator, operating,safety and pilot valves and minimum pressure switch.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by ionisation electrode.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximumselector, operation and block indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
Series BGN…DSPGN from 185 to 738 kW Progressive/modulating two-stage gas burners
0002
4705
81/2
-T
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676
4) Equipped with automatic device for air closing.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
3
3
BGN120PBGN100PBGN60PBGN40PBGN120DSPGN
504846
130120
13001200kW
n
n
m /h G.P.L.
m /h Metano
444240383634323028262422201816141210864
1101009080706050403020
11001000900800700600500400300200
10
100
0002
9222
81-T
BGN60DSPGNBGN40DSPGN BGN100DSPGNBGN120DSPGN MEBGN60DSPGN MEBGN40DSPGN ME BGN100DSPGN ME
mbar14
12
10
0
8
6
4
2
For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Boiler coupling kit
Gas burner accessories
Notes
Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
0085
Thermaloutput
kWElectrical supply
Motor kW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Gastype
Amm
Bmm
Cmm
Dmm
Fmm
BGN 40 DSPGN 540 690 1100 150 ÷ 330 135
BGN 60 DSPGN 630 800 1270 170 ÷ 400 160
ModelGas train is included already; to check if the gas train is suitable for the application, it is necessary to subtract the boiler backpressu-re from the mains gas pressure and select, in the P.Gas column, the value lower than this difference, to which there will correspond acorrect gas train with relative regulator and any adapter. If the difference between mains gas pressure and backpressure is lowerthan the value expressed in the P.Gas column, contact the Sales Office to arrange a non-standard set-up.
P.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
185 ÷ 425 BGN 40 DSPGN 4150010 N.G. 22 97390050 D5 3N AC 50Hz 400V 0,37 1510 x 750 x 720 100 4)
248 ÷ 738 BGN 60 DSPGN 4154010 N.G. 22 97390060 D5 3N AC 50Hz 400V 1,1 1730 x 1030 x 880 123 4)
185 ÷ 425 BGN 40 DSPGN 4150010 N.G. 16 – DE5 3N AC 50Hz 400V 0,37 1510 x 750 x 720 100 4)
248 ÷ 738 BGN 60 DSPGN 4154010 N.G. 16 – DE5 3N AC 50Hz 400V 1,1 1730 x 1030 x 880 123 4)
CE version - Frequency 50 Hz
Export version - Frequency 50 Hz
Export version - Frequency 60 Hz
185 ÷ 425 BGN 40 DSPGN 41505410 N.G. 16 – DE5 3N AC 60Hz 400V 0,55 1510 x 750 x 720 100 4)
248 ÷ 738 BGN 60 DSPGN 41545410 N.G. 16 – DE5 3N AC 60Hz 400V 1,5 1730 x 1030 x 880 123 4)
LPG version available: please contact sales office for quot.
OptionalsDescriptionLDU 11 valve tightness control.
Natural gas
LPG
125
Series BGN…DSPGN from 280 to 1200 kWProgressive/modulating two-stage gas burners
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the controlpanel (to be ordered separately with the modulation kit).
• Ability to operate with any type of combustion chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Minimum and maximum air flow regulation for first andsecond stage by means of electric servomotor with pauseclosure of gate to prevent any heat dispersion to flue.
• A valve tightness control can be fitted on the burner.• Equipped with one flange and one insulating seal
for boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.
• Sliding boiler coupling flange to adapt the headprotrusion to the various types of boilers.
• Adjustable blast-pipe with stainless steel nozzleand deflector disk in steel.
• Three-phase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• In the CE version the gas train is complete with
regulator, operating, safety and pilot valves, minimumpressure switch, pressure regulator and gas filter; inthe EXPORT version the gas train is complete withregulator, operating, safety and pilot valves andminimum pressure switch.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by ionisation electrode.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximumselector, operation and block indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
0002
4705
81/2
-T
Conformi alla:Direttiva gas 90/396/CEE
Direttiva E.M.C. 89/336/CEEDirettiva L.V. 73/23/CEE
Norma di riferimento: EN676
For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Notes
Boiler coupling kit
Gas burner accessories
Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
0085
To choose a suitable gas train, it is necessary to subtract the boiler backpressure from the mains gas pressure and select, in the P.Gascolumn, the value lower than this difference, to which there will correspond a correct gas train with relative regulator and any adapter. Ifthe difference between mains gas pressure and backpressure is lower than the value expressed in the P.Gas column, contact the SalesOffice to arrange a non-standard set-up.
Thermaloutput
kWElectrical supply
Motor kW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Gastype
P.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
280 ÷ 995 BGN 100 DSPGN 4158010 N.G. 30 97390060 D5 3N AC 50Hz 400V 1,1 1730 x 1030 x 880 128 4)
350 ÷ 1200 BGN 120 DSPGN 4162010 N.G. 40 97390060 D5 3N AC 50Hz 400V 1,5 1730 x 1030 x 880 137 4)
280 ÷ 995 BGN 100 DSPGN 4158010 N.G. 17 – DE5 3N AC 50Hz 400V 1,1 1730 x 1030 x 880 128 4)
350 ÷ 1200 BGN 120 DSPGN 4162010 N.G. 22 – DE5 3N AC 50Hz 400V 1,5 1730 x 1030 x 880 137 4)
CE version - Frequency 50 Hz
Export version - Frequency 50 Hz
Export version - Frequency 60 Hz
4) Equipped with automatic device for air closing.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
LPG version available: please contact sales office for quot.
Amm
Bmm
Cmm
Dmm
Fmm
BGN 100 DSPGN 630 815 1330 240 ÷ 460 160
BGN 120 DSPGN 660 855 1400 220 ÷ 440 195
Model
280 ÷ 995 BGN 100 DSPGN 41585410 N.G. 17 – DE5 3N AC 60Hz 400V 1,5 1730 x 1030 x 880 128 4)
350 ÷ 1200 BGN 120 DSPGN 41625410 N.G. 22 – DE5 3N AC 60Hz 400V 2,6 1730 x 1030 x 880 137 4)
OptionalsDescriptionLDU 11 valve tightness control.
3
3
BGN120PBGN100PBGN60PBGN40PBGN120DSPGN
504846
130120
13001200kW
n
n
m /h G.P.L.
m /h Metano
444240383634323028262422201816141210864
1101009080706050403020
11001000900800700600500400300200
10
100
0002
9222
81-T
BGN60DSPGNBGN40DSPGN BGN100DSPGNBGN120DSPGN MEBGN60DSPGN MEBGN40DSPGN ME BGN100DSPGN ME
mbar14
12
10
0
8
6
4
2
Natural gas
LPG
126126
BGN 150 DSPGN
BGN 200 DSPGN BGN 250 DSPGN
BGN 300 DSPGNBGN 150 DSPGN ME BGN 300 DSPGN ME
BGN 350 DSPGNBGN 200 DSPGN ME BGN 250 DSPGN ME BGN 350 DSPGN ME
mn3/h
mn3/h
kW(Metano)
(G.P.L.)40 80 120 160 200 240 280
400 800 1200 1600 2000 2400 2800 3200
320 360 400
3600 4000
10 20 30 40 50 60 70 110 120 130 140 1501009080
17.5
15
12.5
10
20
7.5
5
2.5
0
mbar
BT76
05_5
/1-T
Amm
Bmm
Cmm
Dmm
Fmm
BGN 150 DSPGN 655 990 1500 220 ÷ 440 195
BGN 200 DSPGN 830 1300 1850 300 ÷ 600 220
ModelGas train is included already; to check if the gas train is suitable for the application, it is necessary to subtract the boiler backpressu-re from the mains gas pressure and select, in the P.Gas column, the value lower than this difference, to which there will correspond acorrect gas train with relative regulator and any adapter. If the difference between mains gas pressure and backpressure is lowerthan the value expressed in the P.Gas column, contact the Sales Office to arrange a non-standard set-up.
Series BGN…DSPGN from 414 to 2000 kWProgressive/modulating two-stage gas burners
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the control panel(to be ordered separately with the modulation kit).
• Ability to operate with any type of combustion chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to remove theburner from the boiler.
• Minimum and maximum air flow regulation for first andsecond stage by means of electric servomotor with pauseclosure of gate to prevent any heat dispersion to flue.
• Valves tightness control device compliant withEuropean standard EN676.
• Equipped with one flange and one insulating sealfor boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.
• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan.• Air pressure switch to ensure the presence of combustion air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• In the CE version the gas train is complete with
regulator, operating, safety and pilot valves tightnesscontrol, minimum pressure switch, pressure regulatorand gas filter; in the EXPORT version the gas train iscomplete with regulator, operating, safety and pilotvalves and minimum pressure switch.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by ionisation electrode.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximumselector, operation and block indicator.
• Terminal block for the electrical and thermostatic connectionsto the burner and to control the second stage of working orfor the connection of the electronic output regolator.
• Electrical protection rating IP40.
0002
4705
81/2
-T
4) Equipped with automatic device for air closing.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Conformi alla:Direttiva gas 90/396/CEE
Direttiva E.M.C. 89/336/CEEDirettiva L.V. 73/23/CEE
Norma di riferimento: EN676
For information on the structure, composition, and size of the gas train pleaserefer to the diagrams on page 170.
Boiler coupling kit
Gas burner accessories
Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
0085
Thermaloutput
kWElectrical supply
Motor kW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Gastype
P.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
414 ÷ 1428 BGN 150 DSPGN 4672010 N.G. 27 97390070 D5 3N AC 50Hz 400V 2,2 1730 x 1030 x 880 195 4)
414 ÷ 1428 BGN 150 DSPGN 4672020 N.G. 150 97390053 D5 3N AC 50Hz 400V 2,2 1730 x 1030 x 880 195 4)
590 ÷ 2000 BGN 200 DSPGN 4676010 N.G. 37 97390082 D5 3N AC 50Hz 400V 3 2030 x 1210 x 990 300 4)
590 ÷ 2000 BGN 200 DSPGN 4676020 N.G. 150 97390064 D5 3N AC 50Hz 400V 3 2030 x 1210 x 990 395 4)
414 ÷ 1428 BGN 150 DSPGN 4672010 N.G. 22 – DE5 3N AC 50Hz 400V 2,2 1730 x 1030 x 880 195 4)
414 ÷ 1428 BGN 150 DSPGN 4672020 N.G. 50 – DE5 3N AC 50Hz 400V 2,2 1730 x 1030 x 880 195 4)
590 ÷ 2000 BGN 200 DSPGN 4676010 N.G. 28 – DE5 3N AC 50Hz 400V 3 2030 x 1210 x 990 300 4)
590 ÷ 2000 BGN 200 DSPGN 4676020 N.G. 100 – DE5 3N AC 50Hz 400V 3 2030 x 1210 x 990 395 4)
414 ÷ 1428 BGN 150 DSPGN 46725410 N.G. 22 – DE5 3N AC 60Hz 400V 3,5 1730 x 1030 x 880 195 4)
590 ÷ 2000 BGN 200 DSPGN 46765410 N.G. 28 – DE5 3N AC 60Hz 400V 3,5 2030 x 1210 x 990 300 4)
CE version - Frequency 50 Hz
EXPORT version - Frequency 50 Hz
EXPORT version - Frequency 60 Hz
LPG version available: please contact sales office for quot.
Notes
Natural gas
LPG
127
LPG version available: please contact sales office for quot.
Amm
Bmm
Cmm
Dmm
FmmModel
Gas train is included already; to check if the gas train is suitable for the application, it is necessary to subtract the boiler backpressu-re from the mains gas pressure and select, in the P.Gas column, the value lower than this difference, to which there will correspond acorrect gas train with relative regulator and any adapter. If the difference between mains gas pressure and backpressure is lowerthan the value expressed in the P.Gas column, contact the Sales Office to arrange a non-standard set-up.
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the controlpanel (to be ordered separately with the modulation kit).
• Ability to operate with any type of combustion chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Minimum and maximum air flow regulation for first andsecond stage by means of electric servomotor with pauseclosure of gate to prevent any heat dispersion to flue.
• Valves tightness control device compliant withEuropean standard EN676.
• Equipped with one flange and one insulating sealfor boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.
• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• Three-phase electric motor to run fan.• Air pressure switch to ensure the presence of combustion air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• In the CE version the gas train is complete with
regulator, operating, safety and pilot valves tightnesscontrol, minimum pressure switch, pressure regulatorand gas filter; In the EXPORT version the gas train iscomplete with regulator, operating, safety and pilotvalves and minimum pressure switch.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by ionisation electrode.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximumselector, operation and block indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
Series BGN…DSPGN from 490 to 3500 kWProgressive/modulating two-stage gas burners
BGN 150 DSPGN
BGN 200 DSPGN BGN 250 DSPGN
BGN 300 DSPGNBGN 150 DSPGN ME BGN 300 DSPGN ME
BGN 350 DSPGNBGN 200 DSPGN ME BGN 250 DSPGN ME BGN 350 DSPGN ME
mn3/h
mn3/h
kW(Metano)
(G.P.L.)40 80 120 160 200 240 280
400 800 1200 1600 2000 2400 2800 3200
320 360 400
3600 4000
10 20 30 40 50 60 70 110 120 130 140 1501009080
17.5
15
12.5
10
20
7.5
5
2.5
0
mbar
BT76
05_5
/1-T
0002
4705
81/2
-T
Conformi alla:Direttiva gas 90/396/CEE
Direttiva E.M.C. 89/336/CEEDirettiva L.V. 73/23/CEE
Norma di riferimento: EN676
4) Equipped with automatic device for air closing.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Notes
Boiler coupling kit
Gas burner accessories
Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
BGN 250 DSPGN 875 1235 1850 300 ÷ 600 220
BGN 300 DSPGN 875 1265 1850 275 ÷ 465 275
BGN 350 DSPGN 880 1270 1850 275 ÷ 465 275
For information on the structure, composition, and size of the gas train please refer to thediagrams on page 170.
Thermaloutput
kWElectrical supply
Motor kW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Gastype
P.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
CE version - Frequency 50 Hz490 ÷ 2500 BGN 250 DSPGN 13930050 N.G. 150 97390063 D5 3N AC 50Hz 400V 7,5 2030 x 1210 x 990 297 4)
657 ÷ 2982 BGN 300 DSPGN 4680050 N.G. 150 97390072 D5 3N AC 50Hz 400V 7,5 2030 x 1210 x 990 366 4)
924 ÷ 3500 BGN 350 DSPGN 4684050 N.G. 150 97390073 D5 3N AC 50Hz 400V 7,5 2030 x 1210 x 990 370 4)
490 ÷ 2500 BGN 250 DSPGN 13930050 N.G. 65 – DE5 3N AC 50Hz 400V 7,5 2030 x 1210 x 990 297 4)
657 ÷ 2982 BGN 300 DSPGN 4680050 N.G. 80 – DE5 3N AC 50Hz 400V 7,5 2030 x 1210 x 990 366 4)
924 ÷ 3500 BGN 350 DSPGN 4684050 N.G. 90 – DE5 3N AC 50Hz 400V 7,5 2030 x 1210 x 990 370 4)
490 ÷ 2500 BGN 250 DSPGN 13935410 N.G. 65 – DE5 3N AC 60Hz 400V 9 2030 x 1210 x 990 297 4)
657 ÷ 2982 BGN 300 DSPGN 46805410 N.G. 80 – DE5 3N AC 60Hz 400V 9 2030 x 1210 x 990 366 4)
924 ÷ 3500 BGN 350 DSPGN 46845410 N.G. 90 – DE5 3N AC 60Hz 400V 9 2030 x 1210 x 990 370 4)
EXPORT version - Frequency 60 Hz
EXPORT version - Frequency 50 Hz
0085
Natural gas
LPG
128128
Amm
Bmm
Cmm
Dmm
FmmModel
Gas train is included already; to check if the gas train is suitable for the application, it is necessary to subtract the boiler backpressu-re from the mains gas pressure and select, in the P.Gas column, the value lower than this difference, to which there will correspond acorrect gas train with relative regulator and any adapter. If the difference between mains gas pressure and backpressure is lowerthan the value expressed in the P.Gas column, contact the Sales Office to arrange a non-standard set-up.
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the controlpanel (to be ordered separately with the modulation kit).
• Ability to operate with any type of combustion chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Minimum and maximum air flow regulation for first andsecond stage by means of electric servomotor with pauseclosure of gate to prevent any heat dispersion to flue.
• Valves tightness control device compliant withEuropean standard EN676.
• Equipped with one flange and one insulating sealfor boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.
• Sliding boiler coupling flange to adapt the headprotrusion to the various types of boilers.
• Adjustable blast-pipe with stainless steel nozzleand deflector disk in steel.
• Three-phase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• In the CE version the gas train is complete with regulator,
operating, safety and pilot valves, valve tightness control,minimum pressure switch, pressure regulator and gasfilter; in the EXPORT version gas train is complete withregulator, operating, safety device and pilot valves, valvetightness control and minimum pressure switch.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by UV photo-electronic cell.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximumselector, operation and block indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control the second stageof working or for the connection of the electronic outputregolator.
• Electrical protection rating IP40.
Series GI…DSPGN from 1188 to 5544 kW Progressive/modulating two-stage gas burners
30
0
25
20
15
mbar
10
5
0
0002
9212
92-T
1 8kWx1000
765432
8007006005004003002001003m n/h Metano
GI 420 DSPGNGI 510 DSPGN
GI 350 DSPGN ME GI 510 DSPGN MEGI 350 DSPGN
0002
4705
81/3
-T
GI 350 DSPGN 1160 1585 1970 230 ÷ 600 325
GI 420 DSPGN 1175 1530 2030 320 ÷ 625 355
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Gastype
P.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
1188 ÷ 4752 GI 350 DSPGN 6647050 N.G. 200 97390074 D5 3N AC 50Hz 400V 15 2260 x 1520 x 1200 565 4)
1386 ÷ 5544 GI 420 DSPGN 6650050 N.G. 200 97390083 D5 3N AC 50Hz 400V 18,5 2260 x 1520 x 1200 570 4)
1188 ÷ 4752 GI 350 DSPGN 6647050 N.G. 150 – DE5 3N AC 50Hz 400V 15 2260 x 1520 x 1200 565 4)
1386 ÷ 5544 GI 420 DSPGN 6650050 N.G. 150 – DE5 3N AC 50Hz 400V 18,5 2260 x 1520 x 1200 570 4)
4) Equipped with automatic device for air closing.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Notes
Boiler coupling kit
Gas burner accessories
Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
For information on the structure, composition, and size of the gas train pleaserefer to the diagrams on page 170.
CE version - Frequency 50 Hz
EXPORT version - Frequency 50 Hz
EXPORT version - Frequency 60 Hz1188 ÷ 4752 GI 350 DSPGN 66475410 N.G. 150 – DE5 3N AC 60Hz 400V 11 2260 x 1520 x 1200 565 4)
1386 ÷ 5544 GI 420 DSPGN 66505410 N.G. 150 – DE5 3N AC 60Hz 400V 13 2260 x 1520 x 1200 570 4)
Natural gas
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN676
129
Amm
Bmm
Cmm
Dmm
FmmModel
Gas train is included already; to check if the gas train is suitable for the application, it is necessary to subtract the boiler backpressu-re from the mains gas pressure and select, in the P.Gas column, the value lower than this difference, to which there will correspond acorrect gas train with relative regulator and any adapter. If the difference between mains gas pressure and backpressure is lowerthan the value expressed in the P.Gas column, contact the Sales Office to arrange a non-standard set-up.
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Gas-fired burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the controlpanel (to be ordered separately with the modulation kit).
• Ability to operate with any type of combustion chamber.• Air-gas mixing at blast-pipe.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit can be removed without having to removethe burner from the boiler.
• Minimum and maximum air flow regulation for first andsecond stage by means of electric servomotor with pauseclosure of gate to prevent any heat dispersion to flue.
• Valves tightness control device compliant withEuropean standard EN676.
• Equipped with one flange and one insulating sealfor boiler fastening.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.
• Sliding boiler coupling flange to adapt the headprotrusion to the various types of boilers.
• Adjustable blast-pipe with stainless steel nozzleand deflector disk in steel.
• Three-phase electric motor to run fan.• Air pressure switch to ensure the presence of
combustion air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• In the CE version the gas train is complete with regulator,
operating, safety and pilot valves, valve tightness control,minimum pressure switch, pressure regulator and gasfilter; in the EXPORT version gas train is complete withregulator, operating, safety device and pilot valves, valvetightness control and minimum pressure switch.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by UV photo-electronic cell.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximumselector, operation and block indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control the second stageof working or for the connection of the electronic outputregolator.
• Electrical protection rating IP40.
GI 510 DSPGN from 1300 to 6500 kW Progressive/modulating two-stage gas burners
30
0
25
20
15
mbar
10
5
0
0002
9212
92-T
1 8kWx1000
765432
8007006005004003002001003m n/h Metano
GI 420 DSPGNGI 510 DSPGN
GI 350 DSPGN ME GI 510 DSPGN MEGI 350 DSPGN
0002
4705
81/3
-T
GI 510 DSPGN 1175 1540 2030 320 ÷ 625 355
Thermaloutput
kWElectrical supply
MotorkW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Gastype
P.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
4) Equipped with automatic device for air closing.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.Net calorific value of natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,at reference conditions of 0°C, 1013 mbar.
Notes
Boiler coupling kit
Gas burner accessories
Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
For information on the structure, composition, and size of the gas train pleaserefer to the diagrams on page 170.
CE version - Frequency 50 Hz
EXPORT version - Frequency 50 Hz
EXPORT version - Frequency 60 Hz
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN676
1300 ÷ 6500 GI 510 DSPGN 6653050 N.G. 200 97390083 D5 3N AC 50Hz 400V 18,5 2260 x 1520 x 1200 580 4)
1300 ÷ 6500 GI 510 DSPGN 6653050 N.G. 150 – DE5 3N AC 50Hz 400V 18,5 2260 x 1520 x 1200 580 4)
1300 ÷ 6500 GI 510 DSPGN 66535410 N.G. 150 – DE5 3N AC 60Hz 400V 22 2260 x 1520 x 1200 580 4)
130130
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/light oil burner.• Single stage operation (on/off).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe and high pressure
mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit and the atomisation unit can be removedwithout having to remove the burner from theboiler.
• Manual air flow adjustment.• Possibility to chose gas train with valve tightness
control.• Equipped with one flange and one insulating seal
for boiler fastening, 2 flexible hoses, one linefilter and one nozzle.
• On request: longer blast tube and possibility tomount an automatic device for the switchover offuel outside the burner.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• One monophase electric motor to run the fan and
one to run the pump.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Gear pump with pressure regulator and fuel stop-cock valve.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch, fuel
change switch, and operation, block and fuelindicators.
• Terminal block for the electrical and thermostaticconnections to the burner.
• Electrical protection rating IP40.
MINICOMIST 7 from 38,5 to 66,8 kWSingle-stage gas/light oil dual fuel burners
mbar
3
1 2
2.5
0
2
1.5
1
0.5
2
20
20
2120191817161514131211109876543kg/h
Nm/h240
2422201816141210864
220200180160140120100806040 3
180 220kcal/hx1.000
200160140120100806040kW
0002
9223
22-T
05
MINICOMIST 7 MINICOMIST 11 COMIST 20
0002
5700
51-T
B1B5
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676 end EN267
5) Valve tightness control not required by EN676.CTV)Gas train with Valve Tightness Control.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Line filter - Flex hoses - Nozzle - Boiler coupling kit
Gas burner accessories
OptionalsDescription350 mm long combustion head Device for the automatic fuel switch-over outside the burner.
Notes
38,5 ÷ 66,8 MINICOMIST 7 54700010 1,5 1N AC 50Hz 230V 0,13 + 0,1 575 205 80 510 40 ÷ 156 95 770 x 640 x 680 45
38,5 ÷ 66,8 MINICOMIST 7 54705410 1,5 1N AC 60Hz 230V 0,13 + 0,1 575 205 80 510 40 ÷ 156 95 770 x 640 x 680 45
0085
Amm
B1mm
B5mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
Frequency 50 Hz
Frequency 60 Hz
Natural gas
Light oil
131131
MINICOMIST 7 from 38,5 to 66,8 kWGas train
32A 200 19990338 Included 96000001 M2
CE32B
360 19990002 Included — M2
CTV 360 19990332 Included — M2 5)
MINICOMIST 7NATURAL
32A 200 19990338 Included 96000001 M2GAS
EXP 32B360 19990002 Included — M2
CTV 360 19990332 Included — M2
32J 40 19990235 — — ME1
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
MINICOMIST 7CE
ediz.03/2003
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
30 35 40 45 50 55 60 65 70 75
PORTATA kW
PR
ES
SIO
NE
m
bar
32A
32B
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
132132
MINICOMIST 11 from 58,4 to 103 kWSingle-stage gas/light oil dual fuel burners
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/light oil burner.• Single stage operation (on/off).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe and high pressure
mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit and the atomisation unit can be removedwithout having to remove the burner from theboiler.
• Manual air flow adjustment.• Possibility to chose gas train with valve tightness
control.• Equipped with one flange and one insulating seal
for boiler fastening, 2 flexible hoses, one linefilter and one nozzle.
• On request: longer blast tube and possibility tomount an automatic device for the switchover offuel outside the burner.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• One monophase electric motor to run the fan and
one to run the pump.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Gear pump with pressure regulator and fuel stop-cock valve.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch, fuel
change switch, and operation, block and fuelindicators.
• Terminal block for the electrical and thermostaticconnections to the burner.
• Electrical protection rating IP40.
mbar
3
1 2
2.5
0
2
1.5
1
0.5
2
20
20
2120191817161514131211109876543kg/h
Nm/h240
2422201816141210864
220200180160140120100806040 3
180 220kcal/hx1.000
200160140120100806040kW
0002
9223
22-T
05
MINICOMIST 7 MINICOMIST 11 COMIST 20
0002
5700
51-T
B1B5
5) Valve tightness control not required by EN676.CTV)Gas train with Valve Tightness Control.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Line filter - Flex hoses - Nozzle - Boiler coupling kit
Gas burner accessories
OptionalsDescription350 mm long combustion head Device for the automatic fuel switch-over outside the burner.
Notes
0085
Amm
B1mm
B5mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676 end EN267
58,4 ÷ 103 MINICOMIST 11 54730010 1,5 1N AC 50Hz 230V 0,13 + 0,1 575 205 80 510 40 ÷ 156 95 770 x 640 x 680 45
58,4 ÷ 103 MINICOMIST 11 54735410 1,5 1N AC 60Hz 230V 0,13 + 0,1 575 205 80 510 40 ÷ 156 95 770 x 640 x 680 45
Frequency 50 Hz
Frequency 60 Hz
Natural gas
Light oil
133133
MINICOMIST 11 from 58,4 to 103 kWGas train
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
MINICOMIST 11CE / EXP
ediz.03/2003
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
50 55 60 65 70 75 80 85 90 95 100 105 110
PORTATA kW
PR
ES
SIO
NE
m
bar
33A
33B
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
33A 200 19990338 Included 96000001 M2
MINICOMIST 11NATURAL
CE / EXP33B
360 19990002 Included — M2GAS
CTV 360 19990332 Included — M2 5)
134134
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/light oil burner.• Single stage operation (on/off).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe and high pressure
mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit and the atomisation unit can be removedwithout having to remove the burner from theboiler.
• Manual air flow adjustment.• Possibility to chose gas train with valve tightness
control.• Equipped with one flange and one insulating seal
for boiler fastening, 2 flexible hoses, one linefilter and one nozzle.
• On request: automatic device for the switchover offuel outside the burner.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• One monophase electric motor to run the fan and
one to run the pump.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Gear pump with pressure regulator and fuel stop-cock valve.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch, fuel
change switch, and operation, block and fuelused indicators.
• Terminal block for the electrical and thermostaticconnections to the burner.
• Electrical protection rating IP40.
COMIST 20 from 80 to 230 kWSingle-stage gas/light oil dual fuel burners
mbar
3
1 2
2.5
0
2
1.5
1
0.5
2
20
20
2120191817161514131211109876543kg/h
Nm/h240
2422201816141210864
220200180160140120100806040 3
180 220kcal/hx1.000
200160140120100806040kW
0002
9223
22-T
05
MINICOMIST 7 MINICOMIST 11 COMIST 20
B5
B1F
CA
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676 end EN267
5) Valve tightness control not required by EN676.CTV)Gas train with Valve Tightness Control.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Line filter - Flex hoses - Nozzle - Boiler coupling kit
Supplied accessories
OptionalsDescriptionDevice for the automatic fuel switch-over outside the burner.
Notes
80 ÷ 230 COMIST 20 54770010 1,5 1N AC 50Hz 230V 0,25 + 0,1 660 270 127 820 120 ÷ 290 114 1070 x 720 x 710 61
80 ÷ 230 COMIST 20 54775410 1,5 1N AC 60Hz 230V 0,37 + 0,1 660 270 127 820 120 ÷ 290 114 1070 x 720 x 710 61
0085
Amm
B1mm
B5mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
Frequency 50 Hz
Frequency 60 Hz
Natural gas
Light oil
135135
COMIST 20 from 80 to 230 kWGas train
Perdite di carico(testa di combustione + rampagas +regolatore di pressione)
COMIST 20 CE / EXP
ediz.02/2004
0123456789
101112131415161718192021222324252627282930313233343536373839404142434445
50 75 100 125 150 175 200 225 250 275
PORTATA kW
PR
ES
SIO
NE
m
bar
34A
34C
34B
34A360 19990002 Included 96000003 — M2
CTV 360 19990002 Included 96000003 98000101 M2 5)
COMIST 20NATURAL
CE / EXP 34B360 19990005 Included 96000003 — M2
GAS CTV 360 19990005 Included 96000003 98000101 M2 5)
34C360 19990008 Included — — M2
CTV 360 19990008 Included — 98000101 M2 5)
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
136136
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/light oil burner.• Two-stage pressure stage operation (high/low
flame).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe and high pressure
mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit and the atomisation unit can be removedwithout having to remove the burner from theboiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• Possibility to chose gas train with valve tightnesscontrol.
• Equipped with one flange and one insulating sealfor boiler fastening, 2 flexible hoses, one linefilter and one nozzle.
• On request: automatic device for the switchover offuel outside the burner.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• One monophase electric motor to run the fan and
one to run the pump.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Gear pump with pressure regulator and fuel stop-cock valves.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch, 1st/2nd
stage selector, fuel change switch, and operation,block and fuel used indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
COMIST 26 SP from 130 to 340 kWPressure drop gas/light oil dual fuel burners
320
3130
36
360
COMIST 26 SP
5.5
5
4.5
4
2928272625242322
3432302826
340
300
320300280260
280260240
21
220
201918171615141312111098kg/h Gasolio
Nm/h Metano240
2422201816141210
220200180160140120100
kcal/hx1.000
mbar
3.5
3
2.5
0
2
1.5
1
0.5
200180160140120100kW
0002
9223
20/1
-T03
3
B5
B1F
CA
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676 end EN267
4) Equipped with automatic device for air closing.5) Valve tightness control not required by EN676.CTV)Gas train with Valve Tightness Control.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Line filter - Flex hoses - Nozzle - Boiler coupling kit
Supplied accessories
OptionalsDescriptionDevice for the automatic fuel switch-over outside the burner.
Notes
130 ÷ 340 COMIST 26 SP 54800010 1,5 1N AC 50Hz 230V 0,37 + 0,1 660 270 127 830 140 ÷ 300 135 1030 x 730 x 610 62 4)
130 ÷ 340 COMIST 26 SP 54805410 1,5 1N AC 60Hz 230V 0,37 + 0,1 660 270 127 830 140 ÷ 300 135 1030 x 730 x 610 62 4)
0085
Amm
B1mm
B5mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
Natural gas
Light oil
Frequency 50 Hz
Frequency 60 Hz
137137
COMIST 26 SP from 130 to 340 kWGas train
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
COMIST 26 SPCE / EXP
ediz.02/2004
0
5
10
15
20
25
30
35
40
45
50
55
100 125 150 175 200 225 250 275 300 325 350 375
PORTATA kW
PR
ES
SIO
NE
m
bar
35A
35C
35B
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Valve tightnesscontrol kit
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
35A360 19990020 Included 96000003 — B2
CTV 360 19990020 Included 96000003 98000101 B2 5)
COMIST 26 SPNATURAL
CE / EXP 35B360 19990024 Included — — B2
GAS CTV 360 19990024 Included — 98000101 B2 5)
35C360 19990168 Included — — B2
CTV 360 19990168 Included — 98000101 B2 5)
138138
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/light oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe and high pressure
mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit and the atomisation unit can be removedwithout having to remove the burner from theboiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• Possibility to chose gas train with valve tightnesscontrol.
• Equipped with one flange and one insulating sealfor boiler fastening, 2 flexible hoses, one linefilter and 2 nozzles.
• On request: automatic device for the switchover offuel outside the burner.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Fixed boiler coupling flange.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• A three-phase electric motor to run fan and a
monophase electric motor to run the pump.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Gear pump with pressure regulator, fuel stop-cockvalve and safety valve.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch, 1st/2nd
stage selector, fuel change switch, and operation,block and fuel indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
COMIST 36 from 210 to 438 kWTwo-stage gas/light oil dual fuel burners
Metano
Gasolio
COMIST 36
BT81
87_1
-T
40 8020 60
40 8020 60 100
400 800200 600 1000kWmn3/h
17.5
15
12.5
10
7.5
5
2.5
0
kg/h
mbar
COMIST 72
0002
5700
51/3
-T B1B5
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676 end EN267
4) Equipped with automatic device for air closing.5) Valve tightness control not required by EN676.CTV)Gas train with Valve Tightness Control.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Line filter - Flex hoses - Nozzles - Boiler coupling kit
Supplied accessories
Notes
OptionalsDescriptionDevice for the automatic fuel switch-over outside the burner.
210 ÷ 438 COMIST 36 54910010 1,5 3N AC 50Hz 400V 0,37 + 0,1 485 330 115 1120 380 150 1510 x 750 x 720 115 4)
210 ÷ 438 COMIST 36 54915410 1,5 3N AC 60Hz 400V 0,76 + 0,1 485 330 115 1120 380 150 1510 x 750 x 720 115 4)
0085
Amm
B1mm
B5mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
Frequency 50 Hz
Frequency 60 Hz
Natural gas
Light oil
139139
COMIST 36 from 210 to 438 kWGas train
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
COMIST 36CE / EXP
ediz.03/2003
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
175 200 225 250 275 300 325 350 375 400 425 450 475
PORTATA kW
PR
ES
SIO
NE
m
bar
36A
36C
36B
36A 360 19990411 Included — B2
COMIST 36NATURAL
CE / EXP36B 360 19990410 Included — B2
GAS36C
360 19990404 Included — B2
CTV 360 19990454 Included — B2 5)
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
140140
COMIST 72 from 348 to 916 kWTwo-stage gas/light oil dual fuel burners
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/light oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe and high pressure
mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit and the atomisation unit can be removedwithout having to remove the burner from theboiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• Possibility to chose gas train with valve tightnesscontrol.
• Equipped with one flange and one insulating sealfor boiler fastening, 2 flexible hoses, one linefilter and 2 nozzles.
• On request: automatic device for the switchover offuel outside the burner.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• A three-phase electric motor to run fan and
another to run the pump.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, minimum pressure switch, pressureregulator and gas filter.
• Gear pump with pressure regulator, fuel stop-cockvalve and safety valve.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch, 1st/2nd
stage selector, fuel change switch, and operation,block and fuel indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
Metano
Gasolio
COMIST 36
BT81
87_1
-T
40 8020 60
40 8020 60 100
400 800200 600 1000kWmn3/h
17.5
15
12.5
10
7.5
5
2.5
0
kg/h
mbar
COMIST 72
0002
5700
51/3
-T B1B5
4) Equipped with automatic device for air closing.5) Valve tightness control not required by EN676.6) Where gas pressure at the safety valve is less than 12mbar, replace the
minimum pressure switch with a GW50 pressure switch.CTV)Gas train with Valve Tightness Control. **) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Line filter - Flex hoses - Nozzles - Boiler coupling kit
Supplied accessories
Notes
OptionalsDescriptionDevice for the automatic fuel switch-over outside the burner.
0085
Amm
B1mm
B5mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
348 ÷ 916 COMIST 72 54960010 1,5 3N AC 50Hz 400V 1,1 + 0,37 575 380 135 1310 175 ÷ 345 187 1510 x 750 x 720 150 4)
348 ÷ 916 COMIST 72 54965410 1,5 3N AC 60Hz 400V 1,5 + 0,37 575 380 135 1310 175 ÷ 345 187 1510 x 750 x 720 150 4)
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676 end EN267
Frequency 50 Hz
Frequency 60 Hz
Natural gas
Light oil
141141
COMIST 72 from 348 to 916 kWGas train
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
COMIST 72/72NCE
ediz.02/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
20 30 40 50 60 70 80 90 100
PORTATA kW x10
PR
ES
SIO
NE
m
bar
37B
37C
37A
37D
colore molla regolatore
verde
neutra
Perdite di carico(testa di combustione + rampa gas)
COMIST 72/72NEXP
ediz.02/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
20 30 40 50 60 70 80 90 100
PORTATA kW x10
PR
ES
SIO
NE
m
bar
37B
37C
37A
37J
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Regulatorspring colour
greenneutral
37A 360 19990410 Included — B2
37B360 19990404 Included — B2
CTV 360 19990454 Included — B2 5)
CE37C
360 19990405 Included — B2
CTV 360 19990455 Included — B2 5)
37D200 19990456 97390700 — B4 6)
COMIST 72NATURAL CTV 200 19990457 97390700 — B4 5) 6)
GAS 37A 360 19990410 Included — B2
37B360 19990404 Included — B2
CTV 360 19990454 Included — B2
EXP37C
360 19990405 Included — B2
CTV 360 19990455 Included — B2
37J140 19990456 — — BE4 6)
CTV 140 19990457 — — BE4 6)
142142
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/light oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe and high pressure
mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit and the atomisation unit can be removedwithout having to remove the burner from theboiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• Valves tightness control compliant with Europeanstandard EN676 in the CE execution; on requestin the EXP execution.
• Equipped with one flange and one insulating sealfor boiler fastening, 2 flexible hoses, one linefilter and 2 nozzles.
• On request: automatic device for the switchover offuel outside the burner.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• A three-phase electric motor to run fan and
another to run the pump.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, valves tightness control, minimum pressureswitch, pressure regulator and gas filter.
• Gear pump with pressure regulator, fuel stop-cockvalve and safety valve.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch, 1st/2nd
stage selector, fuel change switch, and operation,block and fuel indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
COMIST 122 from 652 to 1364 kWTwo-stage gas/light oil dual fuel burners
0002
9222
90/1
-T
mbar
30
25
0
20
15
10
5
4500kg/h Gasolio
Nm/h Metano450
kW
3
350025001500500
40035030025020015010050
35030025020015010050
4000300020001000
COMIST 180COMIST 122 COMIST 250 COMIST 300
0002
5700
51/3
-T B1B5
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN676 end EN267
4) Equipped with automatic device for air closing.6) Where gas pressure at the safety valve is less than 12mbar, replace the
minimum pressure switch with a GW50 pressure switch.CTV)Gas train with Valve Tightness Control.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Line filter - Flex hoses - Nozzles - Boiler coupling kit
Supplied accessories
OptionalsDescriptionDevice for the automatic fuel switch-over outside the burner.
Notes
652 ÷ 1364 COMIST 122 55010010 1,5 3N AC 50Hz 400V 2,2 + 0,37 685 490 152 1490 195 ÷ 445 220 1730 x 1030 x 880 187 4)
652 ÷ 1364 COMIST 122 55015410 1,5 3N AC 60Hz 400V 3,5 + 0,37 685 490 152 1490 195 ÷ 445 220 1730 x 1030 x 880 187 4)
Amm
B1mm
B5mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
Frequency 50 Hz
Frequency 60 Hz
Light oil
Natural gas
143143
COMIST 122 from 652 to 1364 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
COMIST 122/122NCE
ediz.04/2003
0
5
10
15
20
25
30
35
40
45
50
55
50 60 70 80 90 100 110 120 130 140 150
PORTATA kW x10
PR
ES
SIO
NE
m
bar 38B
38C
38A
38D
38E
38F
colore molla regolatore
verde
neutra
38A 360 19990454 Included 96000009 B2
38B 360 19990455 Included — B2
CE38C 200 19990457 97390700 — B4 6)
38D 200 19990459 97390700 — B4 6)
38E 200 19990461 97390700 96005002 B5 6)
38F 200 19990463 97390710 96005007 B5
38J360 19990404 Included 96000009 B2
CTV 360 19990454 Included 96000009 B2
COMIST 122 NATURAL
38K360 19990405 Included — B2
GAS CTV 360 19990455 Included — B2
38L140 19990456 — — BE4 6)
EXPCTV 140 19990457 — — BE4 6)
38M140 19990458 — — BE4 6)
CTV 140 19990459 — — BE4 6)
38N140 19990460 — 96005002 BE5 6)
CTV 140 19990461 — 96005002 BE5 6)
38P140 19990462 — 96005007 BE5
CTV 140 19990463 — 96005007 BE5
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Head loss (combustion head + gas train)
Pres
sure
Thermal output
Regulatorspring colour
greenneutral
144144
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/light oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe and high pressure
mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit and the atomisation unit can be removedwithout having to remove the burner from theboiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• Valves tightness control compliant with Europeanstandard EN676 in the CE execution; on requestin the EXP execution.
• Prepared for automatic fuel switching.• Equipped with one flange and one insulating seal
for boiler fastening, 2 flexible hoses, one linefilter and 3 nozzles.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• A three-phase electric motor to run fan and
another to run the pump.• Air pressure switch to ensure the presence of
combustion air.• Gas train complete with operation and safety
valve, valves tightness control, minimum pressureswitch, pressure regulator and gas filter.
• Gear pump with pressure regulator, fuel stop-cockvalve and safety valve.
• Atomisation unit with nozzle-closing pin.• Automatic control and command equipment for the
burner, compliant with European standard EN298.• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch, 1st/2nd
stage selector, fuel change switch, and operation,block and fuel indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
Series COMIST... from 688 to 3878 kWTwo-stage gas/light oil dual fuel burners
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN676 end EN267
0002
9222
90/1
-T
mbar
30
25
0
20
15
10
5
4500kg/h Gasolio
Nm/h Metano450
kW
3
350025001500500
40035030025020015010050
35030025020015010050
4000300020001000
COMIST 180COMIST 122 COMIST 250 COMIST 300
0002
5700
51/3
-T B1B5
Line filter - Flex hoses - Nozzles - Boiler coupling kit
Supplied accessories
688 ÷ 1981 COMIST 180 55060010 1,5 3N AC 50Hz 400V 3 + 0,55 875 450 151 1700 330 ÷ 540 245 1730 x 1030 x 880 233 4) 8)
1127 ÷ 3380 COMIST 250 55110010 1,5 3N AC 50Hz 400V 7,5 + 0,75 1025 580 166 1750 320 ÷ 500 273 2030 x 1210 x 990 330 4) 8)
1304 ÷ 3878 COMIST 300 55160010 1,5 3N AC 50Hz 400V 7,5 + 0,75 1025 580 166 1750 320 ÷ 500 273 2030 x 1210 x 990 330 4) 8)
688 ÷ 1981 COMIST 180 55065410 1,5 3N AC 60Hz 400V 3,5 + 0,65 875 450 151 1700 330 ÷ 540 245 1730 x 1030 x 880 233 4) 8)
1127 ÷ 3380 COMIST 250 55115410 1,5 3N AC 60Hz 400V 9 + 1,3 1025 580 166 1750 320 ÷ 500 273 2030 x 1210 x 990 330 4) 8)
1304 ÷ 3878 COMIST 300 55165410 1,5 3N AC 60Hz 400V 9 + 1,3 1025 580 166 1750 320 ÷ 500 273 2030 x 1210 x 990 330 4) 8)
Amm
B1mm
B5mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°C
4) Equipped with automatic device for air closing.6) Where gas pressure at the safety valve is less than 12mbar, replace the
minimum pressure switch with a GW50 pressure switch.7) Regulator and filter are supplied separately: both must be ordered.8) Can be used for automatic fuel switching.CTV)Gas train with Valve Tightness Control.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Notes
Frequency 50 Hz
Frequency 60 Hz
Light oil
Natural gas
145145
COMIST 180 from 688 to 1981 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
COMIST 180/180NMCE
ediz.02/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210
PORTATA kW x10
PR
ES
SIO
NE
m
bar
39B
39C
39D
39E
39F
39A
colore molla regolatore
verde
neutra
rossa
Perdite di carico(testa di combustione + rampa gas)
COMIST 180/180NMEXP
ediz.02/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210
PORTATA kW x10
PR
ES
SIO
NE
m
bar
39K
39L
39M
39N
39Q
39J
39P
39A 360 19990454 Included — 96000011 B2
39B 360 19990455 Included — 96000012 B2
CE39C 200 19990459 97390700 — 96000012 B4 6)
39D 200 19990461 97390700 — — B5 6)
39E 200 19990463 97390710 — 96005004 B5
39F 200 19990465 97390720 97439999 96005004 B5 7)
39J360 19990404 Included — 96000011 B2
CTV 360 19990454 Included — 96000011 B2
39K360 19990405 Included — 96000012 B2
COMIST 180NATURAL CTV 360 19990455 Included — 96000012 B2
GAS39L
140 19990456 — — 96000012 BE4 6)
CTV 140 19990457 — — 96000012 BE4 6)
EXP 39M140 19990458 — — 96000012 BE4 6)
CTV 140 19990459 — — 96000012 BE4 6)
39N140 19990460 — — — BE5 6)
CTV 140 19990461 — — — BE5 6)
39P140 19990462 — — 96005004 BE5
CTV 140 19990463 — — 96005004 BE5
39Q140 19990464 — — 96005004 BE5
CTV 140 19990465 — — 96005004 BE5
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Burnermodel Pic.
Gas train
Part no.Notes
Gasfilter
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorpo-rated filter without filter
Part no. Part no.
P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Head loss (combustion head + gas train)
Pres
sure
Thermal output
Regulatorspring colour
greenneutralred
146146
COMIST 250 from 1127 to 3380 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
COMIST 250/250NMCE
ediz.04/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
155
5 10 15 20 25 30 35 40
PORTATA kW x100
PR
ES
SIO
NE
m
bar
40B
40D
40E
40A
colore molla regolatore
verde
neutra
rossa
viola
40C
40A200 19990457 97390700 — — B4 6)
500 19990457 97390730 — — B4 6)
40B200 19990459 97390700 — — B4 6)
CE 500 19990459 97390730 — — B4 6)
40C 200 19990461 97390700 — 96005003 B5 6)
40D 200 19990463 97390710 — 96005004 B5
40E 200 19990465 97390720 97439999 96005004 B5 7)
40J140 19990456 — — — BE4 6)
COMIST 250NATURAL CTV 140 19990457 — — — BE4 6)
GAS40K
140 19990458 — — — BE4 6)
CTV 140 19990459 — — — BE4 6)
EXP 40L140 19990460 — — 96005003 BE5 6)
CTV 140 19990461 — — 96005003 BE5 6)
40M140 19990462 — — 96005004 BE5
CTV 140 19990463 — — 96005004 BE5
40N140 19990464 — — 96005004 BE5
CTV 140 19990465 — — 96005004 BE5
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Burnermodel Pic.
Gas train
Part no.Notes
Gasfilter
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorpo-rated filter without filter
Part no. Part no.
P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Head loss (combustion head + gas train)
Pres
sure
Thermal output
Regulatorspring colour
green
neutral
red
violet
147147
COMIST 300 from 1304 to 3878 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
COMIST 300/300NMCE
ediz.04/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
155
160
165
170
5 10 15 20 25 30 35 40 45
PORTATA kW x100
PR
ES
SIO
NE
m
bar
41A
41B
41C
41D
41E
colore molla regolatore
verde
neutra
rossa
viola
41A200 19990457 97390700 — 96000012 B4 6)
500 19990457 97390730 — 96000012 B4 6)
41B200 19990459 97390700 — 96000012 B4 6)
CE 500 19990459 97390730 — 96000012 B4 6)
41C 200 19990461 97390700 — — B5 6)
41D 200 19990463 97390710 — 96005004 B5
41E 200 19990465 97390720 97439999 96005004 B5 7)
41J140 19990456 — — 96000012 BE4 6)
COMIST 300NATURAL CTV 140 19990457 — — 96000012 BE4 6)
GAS41K
140 19990458 — — 96000012 BE4 6)
CTV 140 19990459 — — 96000012 BE4 6)
EXP 41L140 19990460 — — — BE5 6)
CTV 140 19990461 — — — BE5 6)
41M140 19990462 — — 96005004 BE5
CTV 140 19990463 — — 96005004 BE5
41N140 19990464 — — 96005004 BE5
CTV 140 19990465 — — 96005004 BE5
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Burnermodel Pic.
Gas train
Part no.Notes
Gasfilter
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorpo-rated filter without filter
Part no. Part no.
P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Head loss (combustion head + gas train)
Pres
sure
Thermal output
Regulatorspring colour
green
neutral
red
violet
148148
COMIST 72 DSPGM 775 895 1430 175 ÷ 445 220
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°CP.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
COMIST 72 DSPGM from 348 to 916 kWProgressive/modulating two-stage gas/light oil dual fuel burners
0002
5700
51/3
-T
Conform to:Gas Directive 90/396/CEE
E.M.C. Directive 89/336/CEEL.V. Directive 73/23/CEE
Reference standard: EN676 end EN267
4) Equipped with automatic device for air closing.8) Can be used for automatic fuel switching.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Metano
Gasolio
BT
8187
_1/2
-T
40 8020 60 100
40 80 12020 60 100
400 800 1200200 600 1000kWmn3/h
17.5
15
12.5
10
7.5
5
2.5
0
kg/h
mbar
COMIST 72 DSPGM
For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Line filter - Flex hoses - Boiler coupling kit
Amm
Bmm
Cmm
Dmm
FmmModel
Gas train is included already; to check if the gas train is suitable for the application, it is necessary to subtract the boiler backpressu-re from the mains gas pressure and select, in the P.Gas column, the value lower than this difference, to which there will correspond acorrect gas train with relative regulator and any adapter. If the difference between mains gas pressure and backpressure is lowerthan the value expressed in the P.Gas column, contact the Sales Office to arrange a non-standard set-up.
348 ÷ 916 COMIST 72 DSPGM 5227010 1,5 24 97390061 D5 3N AC 50Hz 400V 1,1 + 0,55 1730 x 1030 x 880 205 4) 8)
Supplied accessories
Notes
0085
CE version - Frequency 50 Hz
EXPORT version - Frequency 50 Hz348 ÷ 916 COMIST 72 DSPGM 5227010 1,5 15 – DE5 3N AC 50Hz 400V 1,1 + 0,55 1730 x 1030 x 880 205 4) 8)
60 Hz power supply on request
OptionalsDescriptionLDU 11 valve tightness control.
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/light oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by
means of automatic RWF40 regulator mounted onthe control panel (to be ordered separately withthe modulation kit).
• Ability to operate with any type of combustion chamber.• Air-gas mixing at blast-pipe and high pressure
mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit and the atomisation unit can be removedwithout having to remove the burner from the boiler.
• Minimum and maximum air flow regulation for first andsecond stage by means of electric servomotor with pauseclosure of gate to prevent any heat dispersion to flue.
• A valve tightness control can be fitted on the burner.• Prepared for automatic fuel switching.• Equipped with one flange and one insulating seal
for boiler fastening, 2 flexible hoses and one linefilter; nozzle not included, to be orderedseparately depending on the required flow.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.
• Sliding boiler coupling flange to adapt the headprotrusion to the various types of boilers.
• Adjustable blast-pipe with stainless steel nozzleand deflector disk in steel.
• A three-phase electric motor to run fan andanother to run the pump.
• Air pressure switch to ensure the presence ofcombustion air.
• Electric servomotor with mechanical cam forsimultaneous regulation of combustion air and fuel.
• In the CE version the gas train is complete withregulator, operating, safety and pilot valves, minimumpressure switch, pressure regulator and gas filter; Inthe EXPORT version the gas train is complete withregulator, operating, safety and pilot valves andminimum pressure switch.
• Gear pump with pressure regulator.• Atomisation unit with magnet to control the
outlet/nozzle return pins.• Automatic control and command equipment for the
burner, compliant with European standard EN298.• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximumselector, fuel change switch and operation, blockand fuel indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
Natural gas
Light oil
To complete the burnerNozzle with 1-3 ratio (see page 167).Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
149149
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°CP.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
COMIST 122 DSPGM from 652 to 1364 kWProgressive/modulating two-stage gas/light oil dual fuel burners
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN676 end EN267
0002
5700
51/3
-T
Amm
Bmm
Cmm
Dmm
FmmModel
Gas train is included already; to check if the gas train is suitable for the application, it is necessary to subtract the boiler backpressu-re from the mains gas pressure and select, in the P.Gas column, the value lower than this difference, to which there will correspond acorrect gas train with relative regulator and any adapter. If the difference between mains gas pressure and backpressure is lowerthan the value expressed in the P.Gas column, contact the Sales Office to arrange a non-standard set-up.
4 Equipped with automatic device for air closing.8) Can be used for automatic fuel switching.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Line filter - Flex hoses - Boiler coupling kit
Supplied accessories
Notes
0002
9222
90/2
-T
mbar
30
25
0
20
15
10
5
4500kg/h Gasolio
Nm/h Metano450
kW
3
350025001500500
40035030025020015010050
35030025020015010050
4000300020001000
COMIST 180 DSPGMCOMIST 122 DSPGM COMIST 250 DSPGM COMIST 300 DSPGM
652 ÷ 1364 COMIST 122 DSPGM 5354010 1,5 23 97390070 D5 3N AC 50Hz 400V 2,2 + 0,75 1730 x 1030 x 880 250 4) 8)
COMIST 122 DSPGM 845 1005 1490 195 ÷ 445 220
For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
CE version - Frequency 50 Hz
EXPORT version - Frequency 50 Hz
60 Hz power supply on request
652 ÷ 1364 COMIST 122 DSPGM 5354010 1,5 18 – DE5 3N AC 50Hz 400V 2,2 + 0,75 1730 x 1030 x 880 250 4) 8)
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/light oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by
means of automatic RWF40 regulator mounted onthe control panel (to be ordered separately withthe modulation kit).
• Ability to operate with any type of combustionchamber.
• Air-gas mixing at blast-pipe and high pressuremechanical atomisation of fuel using nozzle.
• Ability to obtain optimal combustion values byregulating combustion air and blast-pipe.
• Maintenance facilitated by the fact that the mixingunit and the atomisation unit can be removed withouthaving to remove the burner from the boiler.
• Minimum and maximum air flow regulation for first andsecond stage by means of electric servomotor with pauseclosure of gate to prevent any heat dispersion to flue.
• Valves tightness control device compliant withEuropean standard EN676.
• Prepared for automatic fuel switching.• Equipped with one flange and one insulating seal
for boiler fastening, 2 flexible hoses and one linefilter; nozzle not included, to be separatelyordered depending on the required flow.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.
• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle and
deflector disk in steel.• A three-phase electric motor to run fan and another
to run the pump.• Air pressure switch to ensure the presence of combustion air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• In the CE version the gas train is complete with regulator,
operating, safety and pilot valves, valve tightness control,minimum pressure switch, pressure regulator and gasfilter; in the EXPORT version gas train is complete withregulator, operating, safety device and pilot valves, valvetightness control and minimum pressure switch.
• Gear pump with pressure regulator.• Atomisation unit with magnet to control the
outlet/nozzle return pins.• Automatic control and command equipment for the
burner, compliant with European standard EN298.• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximum selector, fuelchange switch and operation, block and fuel indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control the secondstage of working or for the connection of theelectronic output regolator.
• Electrical protection rating IP40.
Light oil
Natural gas
To complete the burnerNozzle with 1-3 ratio (see page 167).Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
150150
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°CP.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
COMIST 180 DSPGM from 688 to 1981 kWProgressive/modulating two-stage gas/light oil dual fuel burners
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN676 end EN267
0002
5700
51/3
-T
Amm
Bmm
Cmm
Dmm
FmmModel
Gas train is included already; to check if the gas train is suitable for the application, it is necessary to subtract the boiler backpressu-re from the mains gas pressure and select, in the P.Gas column, the value lower than this difference, to which there will correspond acorrect gas train with relative regulator and any adapter. If the difference between mains gas pressure and backpressure is lowerthan the value expressed in the P.Gas column, contact the Sales Office to arrange a non-standard set-up.
4 Equipped with automatic device for air closing.8) Can be used for automatic fuel switching.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Line filter - Flex hoses - Boiler coupling kit
Supplied accessories
To complete the burnerNozzle with 1-3 ratio (see page 167).Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
Notes
0002
9222
90/2
-T
mbar
30
25
0
20
15
10
5
4500kg/h Gasolio
Nm/h Metano450
kW
3
350025001500500
40035030025020015010050
35030025020015010050
4000300020001000
COMIST 180 DSPGMCOMIST 122 DSPGM COMIST 250 DSPGM COMIST 300 DSPGM
COMIST 180 DSPGM 875 1225 1700 330 ÷ 540 245
For information on the structure, composition, and size of the gas train pleaserefer to the diagrams on page 170.
CE version - Frequency 50 Hz688 ÷ 1981 COMIST 180 DSPGM 5356010 1,5 39 97390082 D5 3N AC 50Hz 400V 3 + 0,75 1730 x 1030 x 880 337 4) 8)
688 ÷ 1981 COMIST 180 DSPGM 5356010 1,5 31 – DE5 3N AC 50Hz 400V 3 + 0,75 1730 x 1030 x 880 337 4) 8)
EXPORT version - Frequency 50 Hz
60 Hz power supply on request
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/light oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the controlpanel (to be ordered separately with the modulation kit).
• Ability to operate with any type of combustionchamber.
• Air-gas mixing at blast-pipe and high pressuremechanical atomisation of fuel using nozzle.
• Ability to obtain optimal combustion values byregulating combustion air and blast-pipe.
• Maintenance facilitated by the fact that the mixingunit and the atomisation unit can be removedwithout having to remove the burner from the boiler.
• Minimum and maximum air flow regulation for first andsecond stage by means of electric servomotor with pauseclosure of gate to prevent any heat dispersion to flue.
• Valves tightness control device compliant withEuropean standard EN676.
• Prepared for automatic fuel switching.• Equipped with one flange and one insulating seal
for boiler fastening, 2 flexible hoses and one linefilter; nozzle not included, to be ordered separatelydepending on the required flow.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.
• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle and
deflector disk in steel.• A three-phase electric motor to run fan and another to
run the pump.• Air pressure switch to ensure the presence of
combustion air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• In the CE version the gas train is complete with regulator,
operating, safety and pilot valves, valve tightness control,minimum pressure switch, pressure regulator and gasfilter; in the EXPORT version gas train is complete withregulator, operating, safety device and pilot valves, valvetightness control and minimum pressure switch.
• Gear pump with pressure regulator.• Atomisation unit with magnet to control the
outlet/nozzle return pins.• Automatic control and command equipment for the
burner, compliant with European standard EN298.• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximum selector, fuelchange switch and operation, block and fuel indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control the secondstage of working or for the connection of the electronicoutput regolator.
• Electrical protection rating IP40.
Light oil
Natural gas
151151
Series COMIST...DSPGM from 1127 to 3878 kWProgressive/modulating two-stage gas/light oil dual fuel burners
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°CP.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/light oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the controlpanel (to be ordered separately with the modulation kit).
• Ability to operate with any type of combustionchamber.
• Air-gas mixing at blast-pipe and high pressuremechanical atomisation of fuel using nozzle.
• Ability to obtain optimal combustion values byregulating combustion air and blast-pipe.
• Maintenance facilitated by the fact that the mixingunit and the atomisation unit can be removedwithout having to remove the burner from the boiler.
• Minimum and maximum air flow regulation for first andsecond stage by means of electric servomotor with pauseclosure of gate to prevent any heat dispersion to flue.
• Valves tightness control device compliant withEuropean standard EN676.
• Prepared for automatic fuel switching.• Equipped with one flange and one insulating seal
for boiler fastening, 2 flexible hoses and one linefilter; nozzle not included, to be ordered separatelydepending on the required flow.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.
• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle and
deflector disk in steel.• A three-phase electric motor to run fan and another to
run the pump.• Air pressure switch to ensure the presence of
combustion air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• In the CE version the gas train is complete with regulator,
operating, safety and pilot valves, valve tightness control,minimum pressure switch, pressure regulator and gasfilter; in the EXPORT version gas train is complete withregulator, operating, safety device and pilot valves, valvetightness control and minimum pressure switch.
• Gear pump with pressure regulator.• Atomisation unit with magnet to control the
outlet/nozzle return pins.• Automatic control and command equipment for the
burner, compliant with European standard EN298.• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximum selector, fuelchange switch and operation, block and fuel indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control the secondstage of working or for the connection of the electronicoutput regolator.
• Electrical protection rating IP40.
0002
5700
51/3
-T
Amm
Bmm
Cmm
Dmm
FmmModel
Gas train is included already; to check if the gas train is suitable for the application, it is necessary to subtract the boiler backpressu-re from the mains gas pressure and select, in the P.Gas column, the value lower than this difference, to which there will correspond acorrect gas train with relative regulator and any adapter. If the difference between mains gas pressure and backpressure is lowerthan the value expressed in the P.Gas column, contact the Sales Office to arrange a non-standard set-up.
4 Equipped with automatic device for air closing.8) Can be used for automatic fuel switching.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Line filter - Flex hoses - Boiler coupling kit
Supplied accessories
To complete the burnerNozzle with 1-3 ratio (see page 167).Modulating modeComplete the burner with the automatic RWF40 regulator and the modulationkit (see page 166).
Notes
0002
9222
90/2
-T
mbar
30
25
0
20
15
10
5
4500kg/h Gasolio
Nm/h Metano450
kW
3
350025001500500
40035030025020015010050
35030025020015010050
4000300020001000
COMIST 180 DSPGMCOMIST 122 DSPGM COMIST 250 DSPGM COMIST 300 DSPGM
COMIST 250 DSPGM 1035 1260 1750 320 ÷ 500 273
COMIST 300 DSPGM 1035 1260 1750 320 ÷ 500 273
For information on the structure, composition, and size of the gas train pleaserefer to the diagrams on page 170.
CE version - Frequency 50 Hz1127 ÷ 3380 COMIST 250 DSPGM 5358050 1,5 150 97390072 D5 3N AC 50Hz 400V 7,5 + 1,5 2030 x 1210 x 990 400 4) 8)
1304 ÷ 3878 COMIST 300 DSPGM 5360050 1,5 150 97390073 D5 3N AC 50Hz 400V 7,5 + 1,5 2030 x 1210 x 990 400 4) 8)
1127 ÷ 3380 COMIST 250 DSPGM 5358050 1,5 70 – DE5 3N AC 50Hz 400V 7,5 + 1,5 2030 x 1210 x 990 400 4) 8)
1304 ÷ 3878 COMIST 300 DSPGM 5360050 1,5 90 – DE5 3N AC 50Hz 400V 7,5 + 1,5 2030 x 1210 x 990 400 4) 8)
EXPORT version - Frequency 50 Hz
60 Hz power supply on request
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN676 end EN267
Light oil
Natural gas
152
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°CP.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
152
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/light oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by
means of automatic RWF40 regulator mounted onthe control panel (to be ordered separately withthe modulation kit).
• Ability to operate with any type of combustionchamber.
• Air-gas mixing at blast-pipe and high pressuremechanical atomisation of fuel using nozzle.
• Ability to obtain optimal combustion values byregulating combustion air and blast-pipe.
• Maintenance facilitated by the fact that the mixingunit and the atomisation unit can be removed withouthaving to remove the burner from the boiler.
• Minimum and maximum air flow regulation for first andsecond stage by means of electric servomotor with pauseclosure of gate to prevent any heat dispersion to flue.
• Valves tightness control device compliant withEuropean standard EN676.
• Prepared for automatic fuel switching.• Equipped with one flange and one insulating seal
for boiler fastening, 2 flexible hoses and one linefilter; nozzle not included, to be orderedseparately depending on the required flow.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.
• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head protrusion
to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle and
deflector disk in steel.• A three-phase electric motor to run fan and another to run
the pump.• Air pressure switch to ensure the presence of combustion air.• Electric servomotor with mechanical cam for simultaneous
regulation of combustion air and fuel.• In the CE version the gas train is complete with regulator,
operating, safety and pilot valves, valve tightness control,minimum pressure switch, pressure regulator and gas filter;in the EXPORT version gas train is complete with regulator,operating, safety device and pilot valves, valve tightnesscontrol and minimum pressure switch.
• Gear pump with pressure regulator.• Atomisation unit with magnet to control the outlet/nozzle
return pins.• Automatic control and command equipment for the burner,
compliant with European standard EN298.• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch, automatic/manual
and minimum/maximum selector, fuel change switch andoperation, block and fuel indicator.
• Terminal block for the electrical and thermostaticconnections to the burner and to control the second stageof working or for the connection of the electronic outputregolator.
• Electrical protection rating IP40.
Series GI MIST...DSPGM from 1581 to 6500 kWProgressive/modulating two-stage gas/light oil dual fuel burners
Amm
Bmm
Cmm
Dmm
FmmModel
Gas train is included already; to check if the gas train is suitable for the application, it is necessary to subtract the boiler backpressu-re from the mains gas pressure and select, in the P.Gas column, the value lower than this difference, to which there will correspond acorrect gas train with relative regulator and any adapter. If the difference between mains gas pressure and backpressure is lowerthan the value expressed in the P.Gas column, contact the Sales Office to arrange a non-standard set-up.
0002
9212
82/5
-T30
0
25
20
15
mbar
10
5
1 8kWx1000
765432
0
800700600500400300200100
3m n/h Metano
kg/h Gasolio600500400300200100
GI MIST 350 DSPGM GI MIST 420 DSPGM GI MIST 510 DSPGM
4) Equipped with automatic device for air closing.8) Can be used for automatic fuel switching.*) Minimum gas train inlet pressure needed to obtain maximum burner power
with a combustion chamber backpressure of zero.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Line filter - Flex hoses - Boiler coupling kit
Supplied accessories
Notes
0002
5700
51/4
-T
1581 ÷ 4743 GI MIST 350 DSPGM 6675050 1,5 200 97390074 D5 3N AC 50Hz 400V 15 + 2,2 2260 x 1520 x 1200 640 4) 8)
1840 ÷ 5522 GI MIST 420 DSPGM 6678050 1,5 200 97390083 D5 3N AC 50Hz 400V 18,5 + 2,2 2260 x 1520 x 1200 680 4) 8)
2430 ÷ 6500 GI MIST 510 DSPGM 6681050 1,5 200 97390083 D5 3N AC 50Hz 400V 18,5 + 3 2260 x 1520 x 1200 700 4) 8)
1581 ÷ 4743 GI MIST 350 DSPGM 6675050 1,5 150 – DE5 3N AC 50Hz 400V 15 + 2,2 2260 x 1520 x 1200 640 4) 8)
1840 ÷ 5522 GI MIST 420 DSPGM 6678050 1,5 150 – DE5 3N AC 50Hz 400V 18,5 + 2,2 2260 x 1520 x 1200 680 4) 8)
2430 ÷ 6500 GI MIST 510 DSPGM 6681050 1,5 150 – DE5 3N AC 50Hz 400V 18,5 + 3 2260 x 1520 x 1200 700 4) 8)
GI MIST 350 DSPGM 1345 1585 1970 230 ÷ 600 325
GI MIST 420 DSPGM 1345 1530 2030 320 ÷ 625 355
GI MIST 510 DSPGM 1345 1540 2030 320 ÷ 625 355
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN676 end EN267
For information on the structure, composition, and size of the gas train pleaserefer to the diagrams on page 170.
CE version - Frequency 50 Hz
EXPORT version - Frequency 50 Hz
60 Hz power supply on request
Natural gas
Light oil
To complete the burner: Nozzle with 1-3 ratio (see page 167).Modulating mode: Complete the burner with the automatic RWF40regulator and the modulation kit (see page 166).
153153
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 20°CP.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/light oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the control panel(to be ordered separately with the modulation kit).
• Ability to operate with any type of combustionchamber.
• Air-gas mixing at blast-pipe and high pressuremechanical atomisation of fuel using nozzle.
• Ability to obtain optimal combustion values byregulating combustion air and blast-pipe.
• Maintenance facilitated by the fact that the mixing unitand the atomisation unit can be removed withouthaving to remove the burner from the boiler.
• Minimum and maximum air flow regulation for first andsecond stage by means of electric servomotor with pauseclosure of gate to prevent any heat dispersion to flue.
• Valves tightness control device compliant with Europeanstandard EN676.
• Prepared for automatic fuel switching.• Equipped with one insulating seal for boiler fastening,
2 flexible hoses and one line filter; nozzle not included,to be separately ordered depending on the requiredflow.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Steel fan part.• High performance centrifugal fan.
• Combustion air intake with air flow adjustment device.• Boiler coupling flange with hinge to facilitate dismantling
of the atomising unit and deflector disk.• Adjustable blast-pipe with stainless steel nozzle and
deflector disk in steel.• A three-phase electric motor to run fan and another to
run the pump.• Air pressure switch to ensure the presence of combustion air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• In the CE version the gas train is complete with regulator,
operating, safety and pilot valves, valve tightness control,minimum pressure switch, pressure regulator and gas filter;in the EXPORT version gas train is complete with regulator,operating, safety device and pilot valves, valve tightnesscontrol and minimum pressure switch.
• Gear pump with pressure regulator.• Atomisation unit with magnet to control the outlet/nozzle
return pins.• Automatic control and command equipment for the
burner, compliant with European standard EN298.• Flame detection by UV photo-electric cell.• On-board terminal box and separate control panel
comprising stop/go switch, automatic/manual andminimum/maximum selector, fuel change switch andoperation, block and fuel indicators.
• Terminal block for the electrical and thermostaticconnections to the burner and to control the secondstage of working or for the connection of the electronicoutput regolator.
• Electrical protection rating IP40.
GI MIST 1000 DSPGM from 2500 to 10500 kWProgressive/modulating two-stage gas/light oil dual fuel burners
Amm
Bmm
Cmm
Dmm
EmmModel
Gas train is included already; to check if the gas train is suitable for the application, it is necessary to subtract the boiler backpressu-re from the mains gas pressure and select, in the P.Gas column, the value lower than this difference, to which there will correspond acorrect gas train with relative regulator and any adapter. If the difference between mains gas pressure and backpressure is lowerthan the value expressed in the P.Gas column, contact the Sales Office to arrange a non-standard set-up.
GI MIST 1000 DSPGM
1110
25
1098
0002
9212
82/6
-T
20
15
mbar
10
5
kWx1000765432
0
800700 900 1000 1100600500400300200100
3m n/h Metano
kg/h Gasolio600500 700 800 900400300200100
4) Equipped with air closure device.8) Can be used for automatic fuel switching.9) On the main gas train regulator and filter are supplied separately; on the pilot
flame gas train the filter is incorporated in the regulator. All components mustbe ordered.
*) Minimum gas train inlet pressure needed to obtain maximum burner power with acombustion chamber backpressure of zero.
Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Light oil: Hi = 42,70 MJ/kg = 10200 kcal/kg.
Line filter - Flex hoses - Boiler coupling kit
Supplied accessories
Notes
C
D
E
B
A
0002
6705
11-T
97390637
2500 ÷ 10500 GI MIST 1000 DSPGM 6687010 1,5 350 97439999 D6 3N AC 50Hz 400V 22 + 4 2600 x 1710 x 1500 980 4) 8) 9)
97390312
2500 ÷ 10500 GI MIST 1000 DSPGM 6687010 1,5 300 – DE6 3N AC 50Hz 400V 22 + 4 2600 x 1710 x 1500 980 4) 8)
GI MIST 1000 DSPGM 1465 1257 2060 440 480
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN676 end EN267
For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
CE version - Frequency 50 Hz
EXPORT version - Frequency 50 Hz
60 Hz power supply on request
Natural gas
Light oil
To complete the burner: Nozzle with 1-5 ratio (see page 167).Modulating mode: Complete the burner with the automatic RWF40regulator and the modulation kit (see page 166).
154154
0002
5700
51/5
-T B1B5
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/heavy oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe and high pressure
mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit and the atomisation unit can be removedwithout having to remove the burner from theboiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• Possibility to chose gas train with valve tightnesscontrol.
• Prepared for automatic fuel switching.• Equipped with one flange and one insulating seal
for boiler fastening, 2 flexible hoses, one linefilter and 2 nozzles.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment
device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.
• Adjustable blast-pipe with stainless steel nozzleand deflector disk in steel.
• A three-phase electric motor to run fan andanother to run the pump.
• Air pressure switch to ensure the presence ofcombustion air.
• Gas train complete with operation and safetyvalve, minimum pressure switch, pressureregulator and gas filter.
• Gear pump with pressure regulator, fuel stop-cockvalve and safety valve.
• Atomisation unit with nozzle-closing pin.• Electrical fuel preheater comprising antigas valve,
filter, thermometer and minimum and regulationthermostat.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch, 1st/2nd
stage selector, fuel change switch, and operation,block, pre-heating resistors on and fuel indicators.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
COMIST 72 N from 348 to 916 kWTwo-stage gas/heavy oil dual fuel burners
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN676
Olio c.
Metano
BT
8187
_1/1
-T
40 80 12020 60 100
400 800 1200200 600 1000
40 8020 60 100
kWmn3/h
17.5
15
12.5
10
7.5
5
2.5
0
kg/h
mbar
COMIST 72 N
Line filter - Flex hoses - Nozzle - Boiler coupling kit
Supplied accessories
348 ÷ 916 COMIST 72 N 55380010 7 3N AC 50Hz 400V 1,1+0,75 575 380 135 1310 175 ÷ 345 187 1730 x 1030 x 880 180 4) 8)
348 ÷ 916 COMIST 72 N 55385410 7 3N AC 60Hz 400V 1,5+0,75 575 380 135 1310 175 ÷ 345 187 1730 x 1030 x 880 180 4) 8)
Amm
B1mm
B5mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 50°C
Frequency 50 Hz
Frequency 60 Hz
4) Equipped with automatic device for air closing.5) Valve tightness control not required by EN676.6) Where gas pressure at the safety valve is less than 12mbar, replace the
minimum pressure switch with a GW50 pressure switch.8) Can be used for automatic fuel switching.CTV)Gas train with Valve Tightness Control. **) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Heavy oil: Hi = 40,19 MJ/kg = 9600 kcal/kg.
Notes
Natural gas
Heavy oil
155155
COMIST 72 N from 348 to 916 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
COMIST 72/72NCE
ediz.02/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
20 30 40 50 60 70 80 90 100
PORTATA kW x10
PR
ES
SIO
NE
m
bar
37B
37C
37A
37D
colore molla regolatore
verde
neutra
Perdite di carico(testa di combustione + rampa gas)
COMIST 72/72NEXP
ediz.02/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
20 30 40 50 60 70 80 90 100
PORTATA kW x10
PR
ES
SIO
NE
m
bar
37B
37C
37A
37J
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
37A 360 19990410 Included — B2
37B360 19990404 Included — B2
CTV 360 19990454 Included — B2 5)
CE37C
360 19990405 Included — B2
CTV 360 19990455 Included — B2 5)
37D200 19990456 97390700 — B4 6)
COMIST 72NNATURAL CTV 200 19990457 97390700 — B4 5) 6)
GAS 37A 360 19990410 Included — B2
37B360 19990404 Included — B2
CTV 360 19990454 Included — B2
EXP37C
360 19990405 Included — B2
CTV 360 19990455 Included — B2
37J140 19990456 — — BE4 6)
CTV 140 19990457 — — BE4 6)
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Head loss (combustion head + gas train)
Pres
sure
Thermal output
Regulatorspring colour
green
neutral
156156
COMIST 122 N from 652 to 1364 kWTwo-stage gas/heavy oil dual fuel burners
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN676
0002
5700
51/5
-T B1B5
Line filter - Flex hoses - Nozzle - Boiler coupling kit.
Supplied accessories
OptionalsDescriptionSteam pre-heater
0002
9222
90-T
mbar
30
25
0
20
15
10
5
4500kg/h Olio c.
Nm/h Metano450
400
kW
3
350025001500500
40035030025020015010050
35030025020015010050
4000300020001000
COMIST 180 NMCOMIST 122 N COMIST 250 NM COMIST 300 NM
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/heavy oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe and high pressure
mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit and the atomisation unit can be removedwithout having to remove the burner from theboiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• On request it is possible to add to the burner asupplementary heavy oil pre-heater using steam,which means the fuel can be heated by the steamfrom the boiler to provide an energy saving.
• Valves tightness control compliant with Europeanstandard EN676 in the CE execution; on requestin the EXP execution.
• Prepared for automatic fuel switching.• Equipped with one flange and one insulating seal
for boiler fastening, 2 flexible hoses, one linefilter and 2 nozzles.
• On request: steam pre-heater.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.
• Combustion air intake with air flow adjustmentdevice.
• Sliding boiler coupling flange to adapt the headprotrusion to the various types of boilers.
• Adjustable blast-pipe with stainless steel nozzleand deflector disk in steel.
• A three-phase electric motor to run fan andanother to run the pump.
• Air pressure switch to ensure the presence ofcombustion air.
• Gas train complete with operation and safetyvalve, valves tightness control, minimum pressureswitch, pressure regulator and gas filter.
• Gear pump with pressure regulator, fuel stop-cockvalve and safety valve.
• Atomisation unit with nozzle-closing pin.• Electrical fuel preheater comprising antigas valve,
filter, thermometer and minimum and regulationthermostat.
• Automatic control and command equipment forthe burner, compliant with European standardEN298.
• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch, 1st/2nd
stage selector, fuel change switch, and operation,block, pre-heating resistors on and fuel indicators.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
652 ÷ 1364 COMIST 122 N 55410010 7 3N AC 50Hz 400V 2,2 + 0,55 940 490 152 1490 195 ÷ 445 220 1730 x 1030 x 880 196 4) 8)
652 ÷ 1364 COMIST 122 N 55415410 7 3N AC 60Hz 400V 3,5 + 0,65 940 490 152 1490 195 ÷ 445 220 1730 x 1030 x 880 196 4) 8)
Amm
B1mm
B5mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 50°C
Frequency 50 Hz
Frequency 60 Hz
4) Equipped with automatic device for air closing.6) Where gas pressure at the safety valve is less than 12mbar, replace the
minimum pressure switch with a GW50 pressure switch.8) Can be used for automatic fuel switching.CTV)Gas train with Valve Tightness Control.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train
for EXP version.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Heavy oil: Hi = 40,19 MJ/kg = 9600 kcal/kg.
Notes
Heavy oil
Natural gas
157157
COMIST 122 N from 652 to 1364 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
COMIST 122/122NCE
ediz.04/2003
0
5
10
15
20
25
30
35
40
45
50
55
50 60 70 80 90 100 110 120 130 140 150
PORTATA kW x10
PR
ES
SIO
NE
m
bar 38B
38C
38A
38D
38E
38F
colore molla regolatore
verde
neutra
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
38A 360 19990454 Included 96000009 B2
38B 360 19990455 Included — B2
CE38C 200 19990457 97390700 — B4 6)
38D 200 19990459 97390700 — B4 6)
38E 200 19990461 97390700 96005002 B5 6)
38F 200 19990463 97390710 96005007 B5
38J360 19990404 Included 96000009 B2
CTV 360 19990454 Included 96000009 B2
COMIST 122N NATURAL
38K360 19990405 Included — B2
GAS CTV 360 19990455 Included — B2
38L140 19990456 — — BE4 6)
EXPCTV 140 19990457 — — BE4 6)
38M140 19990458 — — BE4 6)
CTV 140 19990459 — — BE4 6)
38N140 19990460 — 96005002 BE5 6)
CTV 140 19990461 — 96005002 BE5 6)
38P140 19990462 — 96005007 BE5
CTV 140 19990463 — 96005007 BE5
Burnermodel Pic.
Gas train
Part no.Notes
Burner/gas trainadapter
Part no.
Regulatorwith incorporated filter
Part no.P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Head loss (combustion head + gas train)
Pres
sure
Thermal output
Regulatorspring colour
green
neutral
158158
Series COMIST...NM from 688 to 3878 kWTwo-stage gas/heavy oil dual fuel burners
0002
5700
51/5
-T B1B5
Line filter - Flex hoses - Nozzle - Boiler coupling kit.
Supplied accessories
To complete the burnerNozzle with 1-3 ratio (see page 167).
OptionalsDescription
Steam pre-heater
0002
9222
90-T
mbar
30
25
0
20
15
10
5
4500kg/h Olio c.
Nm/h Metano450
400
kW
3
350025001500500
40035030025020015010050
35030025020015010050
4000300020001000
COMIST 180 NMCOMIST 122 N COMIST 250 NM COMIST 300 NM
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/heavy oil burner.• Two-stage operation (high/low flame).• Ability to operate with any type of combustion
chamber.• Air-gas mixing at blast-pipe and high pressure
mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit and the atomisation unit can be removedwithout having to remove the burner from theboiler.
• Air flow regulation for first and second stage bymeans of electric servomotor with pause closureof gate to prevent any heat dispersion to flue.
• On request it is possible to add to the burner asupplementary heavy oil pre-heater using steam,which means the fuel can be heated by the steamfrom the boiler to provide an energy saving.
• Valves tightness control compliant with Europeanstandard EN676 in the CE execution; on requestin the EXP execution.
• Prepared for automatic fuel switching.• Equipped with one flange and one insulating seal
for boiler fastening, 2 flexible hoses and one linefilter; nozzle not included, to be orderedseparately depending on the required flow.
• On request: steam pre-heater.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.•Adjustable blast-pipe with stainless steel nozzleand deflector disk in steel.
• A three-phase electric motor to run fan andanother to run the pump.
• Air pressure switch to ensure the presence ofcombustion air.
• Gas train complete with operation and safetyvalve, valves tightness control, minimum pressureswitch, pressure regulator and gas filter.
• Gear pump with pressure regulator.• Atomisation unit with magnet to control the
outlet/nozzle return pins.• Electrical fuel preheater comprising antigas valve,
filter, thermometer, regulation thermostats andminimum safety device.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch, 1st/2nd
stage selector, fuel change switch, and operation,block, pre-heating resistors on and fuel indicators.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working.
• Electrical protection rating IP40.
Amm
B1mm
B5mm
Cmm
Dmm
Fmm
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 50°C
688 ÷ 1981 COMIST 180 NM 55460010 7 3N AC 50Hz 400V 3 + 1,1 915 450 151 1700 330 ÷ 540 245 2030 x 1210 x 990 325 4) 8)
1127 ÷ 3380 COMIST 250 NM 55510010 7 3N AC 50Hz 400V 7,5 + 1,1 1025 580 166 1750 320 ÷ 500 273 2030 x 1210 x 990 330 4) 8)
1304 ÷ 3878 COMIST 300 NM 55560010 7 3N AC 50Hz 400V 7,5 + 2,2 1025 580 166 1750 320 ÷ 500 273 2030 x 1210 x 990 330 4) 8)
688 ÷ 1981 COMIST 180 NM 55465410 7 3N AC 60Hz 400V 3,5 + 1,3 915 450 151 1700 330 ÷ 540 245 2030 x 1210 x 990 325 4) 8)
1127 ÷ 3380 COMIST 250 NM 55515410 7 3N AC 60Hz 400V 9 + 1,3 1025 580 166 1750 320 ÷ 500 273 2030 x 1210 x 990 330 4) 8)
1304 ÷ 3878 COMIST 300 NM 55565410 7 3N AC 60Hz 400V 9 + 2,6 1025 580 166 1750 320 ÷ 500 273 2030 x 1210 x 990 330 4) 8)
Frequency 50 Hz
Frequency 60 Hz
4) Equipped with automatic device for air closing.6) Where gas pressure at the safety valve is less than 12mbar, replace the
minimum pressure switch with a GW50 pressure switch.7) Regulator and filter are supplied separately: both must be ordered.8) Can be used for automatic fuel switching.CTV)Gas train with Valve Tightness Control.**) Maximum gas inlet pressure at pressure regulator in CE version, at gas train for EXP version.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Heavy oil: Hi = 40,19 MJ/kg = 9600 kcal/kg.
Notes
Heavy oil
Natural gas
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN676
159159
COMIST 180 NM from 688 to 1981 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
COMIST 180/180NMCE
ediz.02/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210
PORTATA kW x10
PR
ES
SIO
NE
m
bar
39B
39C
39D
39E
39F
39A
colore molla regolatore
verde
neutra
rossa
Perdite di carico(testa di combustione + rampa gas)
COMIST 180/180NMEXP
ediz.02/2004
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210
PORTATA kW x10
PR
ES
SIO
NE
m
bar
39K
39L
39M
39N
39Q
39J
39P
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
39A 360 19990454 Included — 96000011 B2
39B 360 19990455 Included — 96000012 B2
CE39C 200 19990459 97390700 — 96000012 B4 6)
39D 200 19990461 97390700 — — B5 6)
39E 200 19990463 97390710 — 96005004 B5
39F 200 19990465 97390720 97439999 96005004 B5 7)
39J360 19990404 Included — 96000011 B2
CTV 360 19990454 Included — 96000011 B2
39K360 19990405 Included — 96000012 B2
COMIST 180NMNATURAL CTV 360 19990455 Included — 96000012 B2
GAS39L
140 19990456 — — 96000012 BE4 6)
CTV 140 19990457 — — 96000012 BE4 6)
EXP 39M140 19990458 — — 96000012 BE4 6)
CTV 140 19990459 — — 96000012 BE4 6)
39N140 19990460 — — — BE5 6)
CTV 140 19990461 — — — BE5 6)
39P140 19990462 — — 96005004 BE5
CTV 140 19990463 — — 96005004 BE5
39Q140 19990464 — — 96005004 BE5
CTV 140 19990465 — — 96005004 BE5
Burnermodel Pic.
Gas train
Part no.Notes
Gasfilter
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorpo-rated filter without filter
Part no. Part no.
P.Max**mbar
Curveon
graphExecutionVersionGas
type
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Head loss (combustion head + gas train)
Pres
sure
Thermal output
Regulatorspring colour
green
neutral
red
160160
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
COMIST 250/250NMCE
ediz.04/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
155
5 10 15 20 25 30 35 40
PORTATA kW x100
PR
ES
SIO
NE
m
bar
40B
40D
40E
40A
colore molla regolatore
verde
neutra
rossa
viola
40C
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
COMIST 250 NM from 1127 to 3380 kWGas train
40A200 19990457 97390700 — — B4 6)
500 19990457 97390730 — — B4 6)
40B200 19990459 97390700 — — B4 6)
CE 500 19990459 97390730 — — B4 6)
40C 200 19990461 97390700 — 96005003 B5 6)
40D 200 19990463 97390710 — 96005004 B5
40E 200 19990465 97390720 97439999 96005004 B5 7)
40J140 19990456 — — — BE4 6)
COMIST 250NMNATURAL CTV 140 19990457 — — — BE4 6)
GAS40K
140 19990458 — — — BE4 6)
CTV 140 19990459 — — — BE4 6)
EXP 40L140 19990460 — — 96005003 BE5 6)
CTV 140 19990461 — — 96005003 BE5 6)
40M140 19990462 — — 96005004 BE5
CTV 140 19990463 — — 96005004 BE5
40N140 19990464 — — 96005004 BE5
CTV 140 19990465 — — 96005004 BE5
Burnermodel Pic.
Gas train
Part no.Notes
Gasfilter
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorpo-rated filter without filter
Part no. Part no.
P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Head loss (combustion head + gas train)
Pres
sure
Thermal output
Regulatorspring colour
green
neutral
red
violet
161161
COMIST 300 NM from 1304 to 3878 kWGas train
Perdite di carico(testa di combustione + rampa gas + regolatore di pressione)
COMIST 300/300NMCE
ediz.04/2003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
155
160
165
170
5 10 15 20 25 30 35 40 45
PORTATA kW x100
PR
ES
SIO
NE
m
bar
41A
41B
41C
41D
41E
colore molla regolatore
verde
neutra
rossa
viola
BURNER/GAS TRAIN MATCH – CE gas train version complies with EN676, EXP gas train version is for extra-European markets
To choose the correct natural gas train please refer to the information on page 10.For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
41A200 19990457 97390700 — 96000012 B4 6)
500 19990457 97390730 — 96000012 B4 6)
41B200 19990459 97390700 — 96000012 B4 6)
CE 500 19990459 97390730 — 96000012 B4 6)
41C 200 19990461 97390700 — — B5 6)
41D 200 19990463 97390710 — 96005004 B5
41E 200 19990465 97390720 97439999 96005004 B5 7)
41J140 19990456 — — 96000012 BE4 6)
COMIST 300NMNATURAL CTV 140 19990457 — — 96000012 BE4 6)
GAS41K
140 19990458 — — 96000012 BE4 6)
CTV 140 19990459 — — 96000012 BE4 6)
EXP 41L140 19990460 — — — BE5 6)
CTV 140 19990461 — — — BE5 6)
41M140 19990462 — — 96005004 BE5
CTV 140 19990463 — — 96005004 BE5
41N140 19990464 — — 96005004 BE5
CTV 140 19990465 — — 96005004 BE5
Burnermodel Pic.
Gas train
Part no.Notes
Gasfilter
Part no.
Burner/gas trainadapter
Part no.
Regulatorwith incorpo-rated filter without filter
Part no. Part no.
P.Max**mbar
Curveon
graphExecutionVersionGas
type
Head loss (combustion head + gastrain + pressure regulator)
Pres
sure
Thermal output
Head loss (combustion head + gas train)
Pres
sure
Thermal output
Regulatorspring colour
green
neutral
red
violet
162162
60 Hz power supply on request
COMIST 180 DSPNM from 688 to 1981 kWProgressive/modulating two-stage gas/heavy oil dual fuel burners
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN676
4) Equipped with automatic device for air closing.8) Can be used for automatic fuel switching.*) Minimum gas train inlet pressure needed to obtain maximum burner power with a
combustion chamber backpressure of zero.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Heavy oil: Hi = 40,19 MJ/kg = 9600 kcal/kg.
BT81
11_2
/1-T
mbar
500 1000 1500 2000 2500 3000 3500 4000
50 100 150 200 250 300 350
50 100 150 200 250 300 350
kWkg/hmn3/h
4500
400
Olio c.
Metano
400 450
0
5
10
15
20
25
30
COMIST 250 DSPNM
COMIST 300 DSPNM
COMIST 180 DSPNM
0002
5700
51/5
-T03
Line filter - Flex hoses - Boiler coupling kit
Supplied accessories
To complete the burner: Nozzle with 1-3 ratio (see page 167).Modulating mode: Complete the burner with the automatic RWF40regulator and the modulation kit (see page 166).
OptionalsDescriptionSteam pre-heater
Notes
Amm
Bmm
Cmm
Dmm
FmmModel
Gas train is included already; to check if the gas train is suitable for the applica-tion, it is necessary to subtract the boiler backpressure from the mains gas pres-sure and select, in the P.Gas column, the value lower than this difference, towhich there will correspond a correct gas train with relative regulator and anyadapter. If the difference between mains gas pressure and backpressure is lowerthan the value expressed in the P.Gas column, contact the Sales Office to arrangea non-standard set-up.
Thermaloutput
kWSize of packaging
L x P x H mmWeight
kgPart no.Model NotesMaxvisc.
°E at 50°CP.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
688 ÷ 1981 COMIST 180 DSPNM 5428010 7 39 97390082 D5 3N AC 50Hz 400V 3 + 1,1 2030 x 1210 x 990 405 4) 8)
688 ÷ 1981 COMIST 180 DSPNM 5428010 7 31 – DE5 3N AC 50Hz 400V 3 + 1,1 2030 x 1210 x 990 405 4) 8)
COMIST 180 DSPNM 915 1225 1700 330 ÷ 540 245
Electrical supply
MotorskW
For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
CE version - Frequency 50 Hz
EXPORT version - Frequency 50 Hz
Heavy oil
Natural gas
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/heavy oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the controlpanel (to be ordered separately with the modulation kit).
• Ability to operate with any type of combustion chamber.• Air-gas mixing at blast-pipe and high pressure
mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit and the atomisation unit can be removed withouthaving to remove the burner from the boiler.
• Minimum and maximum air flow regulation for first andsecond stage by means of electric servomotor with pauseclosure of gate to prevent any heat dispersion to flue.
• On request it is possible to add to the burner asupplementary heavy oil pre-heater using steam,which means the fuel can be heated by the steamfrom the boiler to provide an energy saving.
• Valves tightness control device compliant withEuropean standard EN676.
• Prepared for automatic fuel switching.• Equipped with one flange and one insulating seal
for boiler fastening, 2 flexible hoses and one linefilter; nozzle not included, to be orderedseparately depending on the required flow.
• On request: steam pre-heater.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.
• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• A three-phase electric motor to run fan and
another to run the pump.• Air pressure switch to ensure the presence of
combustion air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• In the CE version the gas train is complete with regulator,
operating, safety and pilot valves, valve tightness control,minimum pressure switch, pressure regulator and gasfilter; in the EXPORT version gas train is complete withregulator, operating, safety device and pilot valves, valvetightness control and minimum pressure switch.
• Gear pump with pressure regulator.• Atomisation unit with magnet to control the
outlet/nozzle return pins.• Electrical fuel preheater comprising antigas valve,
filter, thermometer, regulation thermostats andminimum safety device.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximumselector, fuel change switch and operation, block,pre-heating resistors on and fuel indicators.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
163163
60 Hz power supply on request
Series COMIST...DSPNM from 1127 to 3878 kWProgressive/modulating two-stage gas/heavy oil dual fuel burners
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN676
4) Equipped with automatic device for air closing.8) Can be used for automatic fuel switching.*) Minimum gas train inlet pressure needed to obtain maximum burner power with a
combustion chamber backpressure of zero.Net calorific value:Natural gas: Hi = 35,80 MJ/m3 = 8550 kcal/m3,
at reference conditions of 0°C, 1013 mbar;Heavy oil: Hi = 40,19 MJ/kg = 9600 kcal/kg.
BT81
11_2
/1-T
mbar
500 1000 1500 2000 2500 3000 3500 4000
50 100 150 200 250 300 350
50 100 150 200 250 300 350
kWkg/hmn3/h
4500
400
Olio c.
Metano
400 450
0
5
10
15
20
25
30
COMIST 250 DSPNM
COMIST 300 DSPNM
COMIST 180 DSPNM
0002
5700
51/5
-T03
Line filter - Flex hoses - Boiler coupling kit
Supplied accessories
To complete the burner: Nozzle with 1-3 ratio (see page 167).Modulating mode: Complete the burner with the automatic RWF40regulator and the modulation kit (see page 166).
Notes
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/heavy oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by means of
automatic RWF40 regulator mounted on the controlpanel (to be ordered separately with the modulation kit).
• Ability to operate with any type of combustion chamber.• Air-gas mixing at blast-pipe and high pressure
mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit and the atomisation unit can be removed withouthaving to remove the burner from the boiler.
• Minimum and maximum air flow regulation for first andsecond stage by means of electric servomotor with pauseclosure of gate to prevent any heat dispersion to flue.
• On request it is possible to add to the burner asupplementary heavy oil pre-heater using steam,which means the fuel can be heated by the steamfrom the boiler to provide an energy saving.
• Valves tightness control device compliant withEuropean standard EN676.
• Prepared for automatic fuel switching.• Equipped with one flange and one insulating seal
for boiler fastening, 2 flexible hoses and one linefilter; nozzle not included, to be orderedseparately depending on the required flow.
• On request: steam pre-heater.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.• High performance centrifugal fan.
• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle
and deflector disk in steel.• A three-phase electric motor to run fan and
another to run the pump.• Air pressure switch to ensure the presence of
combustion air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• In the CE version the gas train is complete with regulator,
operating, safety and pilot valves, valve tightness control,minimum pressure switch, pressure regulator and gasfilter; in the EXPORT version gas train is complete withregulator, operating, safety device and pilot valves, valvetightness control and minimum pressure switch.
• Gear pump with pressure regulator.• Atomisation unit with magnet to control the
outlet/nozzle return pins.• Electrical fuel preheater comprising antigas valve,
filter, thermometer, regulation thermostats andminimum safety device.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximumselector, fuel change switch and operation, block,pre-heating resistors on and fuel indicators.
• Terminal block for the electrical and thermostaticconnections to the burner and to control thesecond stage of working or for the connection ofthe electronic output regolator.
• Electrical protection rating IP40.
Amm
Bmm
Cmm
Dmm
FmmModel
Gas train is included already; to check if the gas train is suitable for the applica-tion, it is necessary to subtract the boiler backpressure from the mains gas pres-sure and select, in the P.Gas column, the value lower than this difference, towhich there will correspond a correct gas train with relative regulator and anyadapter. If the difference between mains gas pressure and backpressure is lowerthan the value expressed in the P.Gas column, contact the Sales Office to arrangea non-standard set-up.
Thermaloutput
kWSize of packaging
L x P x H mmWeight
kgPart no.Model NotesMaxvisc.
°E at 50°CP.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
COMIST 250 DSPNM 1035 1260 1750 320 ÷ 500 273
COMIST 300 DSPNM 1035 1260 1750 320 ÷ 500 273
Electrical supply
MotorskW
For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
CE version - Frequency 50 Hz
EXPORT version - Frequency 50 Hz
1127 ÷ 3380 COMIST 250 DSPNM 5430050 7 150 97390072 D5 3N AC 50Hz 400V 7,5 + 1,1 2030 x 1210 x 990 428 4) 8)
1304 ÷ 3878 COMIST 300 DSPNM 5432050 7 150 97390073 D5 3N AC 50Hz 400V 7,5 + 2,2 2030 x 1210 x 990 448 4) 8)
1127 ÷ 3380 COMIST 250 DSPNM 5430050 7 70 – DE5 3N AC 50Hz 400V 7,5 + 1,1 2030 x 1210 x 990 428 4) 8)
1304 ÷ 3878 COMIST 300 DSPNM 5432050 7 90 – DE5 3N AC 50Hz 400V 7,5 + 2,2 2030 x 1210 x 990 448 4) 8)
Heavy oil
Natural gas
OptionalsDescriptionSteam pre-heater
164164
60 Hz power supply on request
0002
9212
82/7
-T30
0
25
20
15
mbar
10
5
1 8kWx1000
765432
800700600500400300200100
3m n/h Metano
0 700600500400300200100kg/h Olio c.
GI MIST 510 DSPNMGI MIST 420 DSPNMGI MIST 350 DSPNM
Series GI MIST...DSPNM from 1581 to 6500 kWProgressive/modulating two-stage gas/heavy oil dual fuel burners
Conformi alla:Direttiva E.M.C. 89/336/CEE
Direttiva L.V. 73/23/CEEReference standard: EN676
4) Equipped with automatic device for air closing.8) Can be used for automatic fuel switching.*) Minimum gas train inlet pressure needed to obtain maximum burner power with a
combustion chamber backpressure of zero.
0002
5700
51/6
-T
Line filter - Flex hoses - Boiler coupling kit
Supplied accessories
OptionalsDescriptionSteam pre-heater
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/heavy oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by
means of automatic RWF40 regulator mounted onthe control panel (to be ordered separately withthe modulation kit).
• Ability to operate with any type of combustion chamber.• Air-gas mixing at blast-pipe and high pressure
mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit and the atomisation unit can be removed withouthaving to remove the burner from the boiler.
• Minimum and maximum air flow regulation forfirst and second stage by means of electricservomotor with pause closure of gate to preventany heat dispersion to flue.
• On request it is possible to add to the burner asupplementary heavy oil pre-heater using steam,which means the fuel can be heated by the steamfrom the boiler to provide an energy saving.
• Valves tightness control device compliant withEuropean standard EN676.
• Prepared for automatic fuel switching.• Equipped with one flange and one insulating seal
for boiler fastening, 2 flexible hoses and one linefilter; nozzle not included, to be orderedseparately depending on the required flow.
• On request: steam pre-heater.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Light aluminium alloy fan part.
• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Sliding boiler coupling flange to adapt the head
protrusion to the various types of boilers.• Adjustable blast-pipe with stainless steel nozzle and
deflector disk in steel.• A three-phase electric motor to run fan and another to
run the pump.• Air pressure switch to ensure the presence of
combustion air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• In the CE version the gas train is complete with regulator,
operating, safety and pilot valves, valve tightness control,minimum pressure switch, pressure regulator and gasfilter; in the EXPORT version gas train is complete withregulator, operating, safety device and pilot valves, valvetightness control and minimum pressure switch.
• Gear pump with pressure regulator.• Atomisation unit with magnet to control the
outlet/nozzle return pins.• Electrical fuel preheater comprising antigas valve, filter,
thermometer, regulation thermostats and minimumsafety device.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by UV photo-electric cell.• Control panel comprising stop/go switch,
automatic/manual and minimum/maximum selector,fuel change switch and operation, block, pre-heatingresistors on and fuel indicators.
• Terminal block for the electrical and thermostaticconnections to the burner and to control the secondstage of working or for the connection of the electronicoutput regolator.
• Electrical protection rating IP40.
Amm
Bmm
Cmm
Dmm
FmmModel
Gas train is included already; to check if the gas train is suitable for the applica-tion, it is necessary to subtract the boiler backpressure from the mains gas pres-sure and select, in the P.Gas column, the value lower than this difference, towhich there will correspond a correct gas train with relative regulator and anyadapter. If the difference between mains gas pressure and backpressure is lowerthan the value expressed in the P.Gas column, contact the Sales Office to arrangea non-standard set-up.
Thermaloutput
kWSize of packaging
L x P x H mmWeight
kgPart no.Model NotesMaxvisc.
°E at 50°CP.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
1581 ÷ 4743 GI MIST 350 DSPNM 6705050 7 200 97390074 D5 3N AC 50Hz 400V 15 + 2,2 2260 x 1520 x 1200 802 4) 8)
1840 ÷ 5522 GI MIST 420 DSPNM 6708050 7 200 97390083 D5 3N AC 50Hz 400V 18,5 + 3 2260 x 1520 x 1200 847 4) 8)
2430 ÷ 6500 GI MIST 510 DSPNM 6711050 7 200 97390083 D5 3N AC 50Hz 400V 18,5 + 3 2260 x 1520 x 1200 870 4) 8)
1581 ÷ 4743 GI MIST 350 DSPNM 6705050 7 150 – DE5 3N AC 50Hz 400V 15 + 2,2 2260 x 1520 x 1200 802 4) 8)
1840 ÷ 5522 GI MIST 420 DSPNM 6708050 7 150 – DE5 3N AC 50Hz 400V 18,5 + 3 2260 x 1520 x 1200 847 4) 8)
2430 ÷ 6500 GI MIST 510 DSPNM 6711050 7 150 – DE5 3N AC 50Hz 400V 18,5 + 3 2260 x 1520 x 1200 870 4) 8)
GI MIST 350 DSPNM 1345 1585 1970 230 ÷ 600 325
GI MIST 420 DSPNM 1345 1530 2030 320 ÷ 625 355
GI MIST 510 DSPNM 1345 1530 2030 320 ÷ 625 355
Electrical supply
MotorskW
For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
Notes
CE version - Frequency 50 Hz
EXPORT version - Frequency 50 Hz
Natural gas
Heavy oil
To complete the burner: Nozzle with 1-3 ratio (see page 167).Modulating mode: Complete the burner with the automatic RWF40regulator and the modulation kit (see page 166).
165165
Notes
4) Equipped with automatic device for air closing.8) Can be used for automatic fuel switching.9) On the main gas train regulator and filter are supplied separately; on the pilot flame
gas train the filter is incorporated in the regulator. All components must be ordered.*) Minimum gas train inlet pressure needed to obtain maximum burner power with a
combustion chamber backpressure of zero.
GI MIST 1000 DSPNM30
1110
25
1098
0002
9212
81/8
-T
20
15
mbar
10
5
kWx1000765432
800700 900 1000 1100600500400300200100
3m n/h Metano
0 700600 800 900500 1000400300200100kg/h Olio c.
C
D
E
B
A
0002
6705
11-T
GI MIST 1000 DSPNM from 2500 to 10500 kWProgressive/modulating two-stage gas/heavy oil dual fuel burners
Conform to:E.M.C. Directive 89/336/CEE
L.V. Directive 73/23/CEEReference standard: EN676
Line filter - Flex hoses - Boiler coupling kit
Supplied accessories
TECHNICAL AND FUNCTIONALCHARACTERISTICS• Alternate natural gas/heavy oil burner.• Two-stage progressive output operation.• Ability to operate with output modulation by
means of automatic RWF40 regulator mounted onthe control panel (to be ordered separately withthe modulation kit).
• Ability to operate with any type of combustion chamber.• Air-gas mixing at blast-pipe and high pressure
mechanical atomisation of fuel using nozzle.• Ability to obtain optimal combustion values by
regulating combustion air and blast-pipe.• Maintenance facilitated by the fact that the mixing
unit and the atomisation unit can be removed withouthaving to remove the burner from the boiler.
• Minimum and maximum air flow regulation forfirst and second stage by means of electricservomotor with pause closure of gate to preventany heat dispersion to flue.
• On request it is possible to add to the burner asupplementary heavy oil pre-heater using steam,which means the fuel can be heated by the steamfrom the boiler to provide an energy saving.
• Valves tightness control device compliant withEuropean standard EN676.
• Prepared for automatic fuel switching.• Equipped with one insulating seal for boiler
fastening, 2 flexible hoses and one line filter;nozzle not included, to be ordered separatelydepending on the required flow.
• On request: steam pre-heater.
CONSTRUCTION CHARACTERISTICSThe burner consists of:• Steel fan part.
• High performance centrifugal fan.• Combustion air intake with air flow adjustment device.• Boiler coupling flange with hinge to facilitate
dismantling of the atomising unit and deflector disk.• Adjustable blast-pipe with stainless steel nozzle and
deflector disk in steel.• A three-phase electric motor to run fan and another to
run the pump.• Air pressure switch to ensure the presence of combustion air.• Electric servomotor with mechanical cam for
simultaneous regulation of combustion air and fuel.• In the CE version the gas train is complete with regulator,
operating, safety and pilot valves, valve tightness control,minimum pressure switch, pressure regulator and gasfilter; in the EXPORT version gas train is complete withregulator, operating, safety device and pilot valves, valvetightness control and minimum pressure switch.
• Gear pump with pressure regulator.• Atomisation unit with magnet to control the
outlet/nozzle return pins.• Two electrical preheaters in series and mounted on a
frame comprising antigas valve, self-cleaning filter,thermometer, electronic temperature regulation andsafety thermostats.
• Automatic control and command equipment for theburner, compliant with European standard EN298.
• Flame detection by UV photo-electric cell.• On-board terminal box and separate control panel
comprising stop/go switch, automatic/manual andminimum/maximum selector, fuel change switch andoperation, block, pre-heating resistors on and fuel indicators.
• Terminal block for the electrical and thermostaticconnections to the burner and to control the secondstage of working or for the connection of the electronicoutput regolator.
• Electrical protection rating IP40.
Amm
Bmm
Cmm
Dmm
Emm
GI MIST 1000 DSPNM 1465 1257 2060 440 480
Model
Gas train is included already; to check if the gas train is suitable for the appli-cation, it is necessary to subtract the boiler backpressure from the mains gaspressure and select, in the P.Gas column, the value lower than this difference, towhich there will correspond a correct gas train with relative regulator and anyadapter. If the difference between mains gas pressure and backpressure is lowerthan the value expressed in the P.Gas column, contact the Sales Office to arrangea non-standard set-up.
Thermaloutput
kWElectrical supply
MotorskW
Size of packagingL x P x H mm
WeightkgPart no.Model Notes
Maxvisc.
°E at 50°CP.Gas*mbar Pic.
Regulatorwith incorporated filterPart no.
97390637
2500 ÷ 10500 GI MIST 1000 DSPNM 6717010 7 350 97439999 D6 3N AC 50Hz 400V 22 + 4 2600 x 1700 x 1500 1120 4) 8) 9)
97390312
2500 ÷ 10500 GI MIST 1000 DSPNM 6717010 7 300 – DE6 3N AC 50Hz 400V 22 + 4 2600 x 1700 x 1500 1120 4) 8)
For information on the structure, composition, and size of the gas train please refer to the diagrams on page 170.
CE version - Frequency 50 Hz
EXPORT version - Frequency 50 Hz
OptionalsDescriptionSteam pre-heater
Natural gas
Heavy oil
To complete the burner: Nozzle with 1-5 ratio (see page 167).Modulating mode: Complete the burner with the automatic RWF40regulator and the modulation kit (see page 166).
166166
RWF 40 electronic regulator for all modulating burners, used to regulatetemperature or pressure.
Modulation kits
By inserting the RWF40 kit and the modulating kit intothe two progressive stage burners, these are trasformedinto modulating burners, that is, with the capacity toprovide thermal power which can be varied continuou-sly in accordance with the specific needs of the boiler.Naturally, the thermal power level varies only withinthe “minimum” and “maximum” limits applying to theburner.
Selecting modulation kit componentsWith reference to parameter: temperature (°C) orpressure (bar), select the regulation range correspon-ding to the operating value of the boiler. When thevalue falls within two different setting ranges, selectthe lower of the two.
Example:If the temperature of the water in the boiler is to be100°C, choose the modulation kit corresponding torange 0÷130°C. If the pressure of the steam in theboiler is to be 8 bar, select the modulation kit in theregulation range 0÷10 bar.
Part no. Model
98000051 Kit RWF 40
98000052 Kit RWF 40 for SPARKGAS 30 LX
Part no. TemperatureType Probe Male
probe length coupling
Part no. Steam pressureMale
coupling
98000020 0 °C ÷ 130 °C NI 1000 100 1) R 1/2”
98000021 0 °C ÷ 500 °C PT 1000 200 1) G 1/2”
98000022 0 °C ÷ 1100 °C Thermocouple 425 1) R 1/2”
For different modulation values please contact our Technical Assistance Service.1) Different lengths on request.
Notes
Automatic proportional modulation regulator
Temperature modulation kit
Steam pressure modulation kit
98000025 0 ÷ 1 bar G 1/2”
98000026 0 ÷ 10 bar G 1/2”
98000027 0 ÷ 16 bar G 1/2”
98000028 0 ÷ 25 bar G 1/2”
98000029 0 ÷ 40 bar G 1/2”
167167
Return nozzles
Part no.Rated Flow-rate
flow-rate anglekg/h
Part no.Rated Flow-rate
flow-rate anglekg/h
98000201 50 45°
98000202 60 45°
98000203 70 45°
98000204 80 45°
98000205 90 45°
98000206 100 45°
98000207 125 45°
98000208 150 45°
98000209 175 45°
98000210 200 45°
98000211 225 45°
98000212 250 45°
98000213 275 45°
98000214 300 45°
98000215 325 45°
98000216 350 45°
98000217 375 45°
98000218 400 45°
98000219 425 45°
98000220 450 45°
98000221 475 45°
98000222 500 45°
98000223 525 45°
98000224 550 45°
98000225 575 45°
98000226 600 45°
98000227 650 45°
98000228 700 45°
98000229 750 45°
98000230 800 45°
98000231 850 45°
98000232 900 45°
98000233 1000 45°
Burner nozzles for light oil and heavy oil (ratio 1:3) for progressive/modulating two-stage burnersand two-stage burners for heavy oil (GI 1000 excluded).
Part no.Rated Flow-rate
flow-rate anglekg/h
Part no.Rated Flow-rate
flow-rate anglekg/h
98000280 700 45°
98000281 750 45°
98000282 800 45°
98000283 850 45°
98000284 900 45°
98000285 1000 45°
Light oil and heavy oil burner nozzles (ratio 1:5)for GI 1000 burners only
Return nozzle with 1:5 modulation ratio for light oil/heavy oil modulating, two-stage progressive burners andheavy oil two-stage burners. This type of nozzle maintains pump pressure constant and varies fuel flow rate on thebasis of nozzle return pressure.
Goods supplied:To be ordered together with burner at the time of the order itselfaccording to the power requested for the application.
Return nozzle with 1:3 modulation ratio for light oil/heavy oil modulating, two-stage progressive burners andheavy oil two-stage burners. This type of nozzle maintains pump pressure constant and varies fuel flow rate on thebasis of nozzle return pressure.
168168
Accessories for connection of burners to gas mains
Part no. ModelConnections
diameter
97390010 BTFR/2CE 1/2"
97390020 BTFR/2CE 3/4"
97390030 BTFR/2CE 1"
97390040 BTFR/2CE 1"1/4
97390050 BTFR/2CE 1"1/2
97390060 BTFR/2CE 2"
97390070 BTFR/2CE DN 65
97390080 BTFR/2CE DN 80
CE gas pressure regulator with incorporated filterClosure control, upstream side / downstream side pressure take-offs, safety diaphragm.Max inlet pressure: 200 mbar.Outlet pressure: 6 - 150 mbar.
97390310 BTFR/5CE 1/2"
97390320 BTFR/5CE 3/4"
97390330 BTFR/5CE 1"
97390340 BTFR/5CE 1"1/4
97390350 BTFR/5CE 1"1/2
97390360 BTFR/5CE 2"
97390370 BTFR/5CE DN 65
97390380 BTFR/5CE DN 80
97390546 BTFR/1000 1"1/4
97390556 BTFR/1000 1"1/2
97390566 BTFR/1000 2”
97390576 BTFR/1000 DN65
97390586 BTFR/1000 DN80
Max inlet pressure: 500 mbar.Outlet pressure: 6 - 150 mbar.
Gas pressure regulator with incorporated filter.Closure control, upstream side / downstream side pressure take-offs, safety diaphragm.Max inlet pressure: 1000 mbar.Outlet pressure: 150 - 270 mbar.
169169
Accessories for connection of burners to gas mains
Max inlet pressure: 500 mbar.Outlet pressure: 6 - 150 mbar.
97390110 BTR/2CE DN 65
97390120 BTR/2CE DN 80
97390090 BTR/2CE DN 100
CE gas pressure regulatorClosure control, upstream side / downstream side pressure take-offs, safety diaphragm.Maximum pressure: 200 mbar.Outlet pressure: 6 - 150 mbar.
97390410 BTR/5CE DN 65
97390420 BTR/5CE DN 80
97390390 BTR/5CE DN 100
97390616 BTR/1000 DN 65
97390626 BTR/1000 DN 80
97360636 BTR/1000 DN 100
97029999 BTGA 1/2" MM
97039999 BTGA 3/4" MM
97049999 BTGA 1" MM
97059999 BTGA 1" 1/4 MM
97069999 BTGA 1" 1/2 MM
97079999 BTGA 2" MM
97089999 BTGA DN 65 - PN 16
97099999 BTGA DN 80 - PN 16
97109999 BTGA DN 100 - PN 16
97119999 BTGA DN 125 - PN 16
97129999 BTGA DN 150 - PN 16
97679999 BTVS 3/8" FF
97689999 BTVS 1/2" FF
97699999 BTVS 3/4" FF
97709999 BTVS 1" FF
97719999 BTVS 1" 1/4 FF
97729999 BTVS 1" 1/2 FF
97739999 BTVS 2" FF
97749999 BTVS DN 65-PN16
97759999 BTVS DN 80-PN16
97769999 BTVS DN 100-PN16
97419999 BTF DN 65
97429999 BTF DN 80
97439999 BTF DN 100
97449999 BTF DN 150
Gas pressure regulatorClosure control, flanged PN 16, upstream side / downstream side pressure take-offs, safety diaphragm.Max pressure: 1000 mbar.Outlet pressure: 150 - 270 mbar.
CE anti-vibration and compensation jointsDIN 30681 stainless steel.
CE ball valves
CE gas filtersFlanged PN 16, with pressure take-off.
Part no. ModelConnections
diameter
170170
19990436 ● ● ● ● 1" 3/4" 3/4" 1" 72 235 256 520 x 410 x 460 11
19990438 ● ● ● ● 1"1/2 1" 1" 1"1/2 83 235 296 520 x 410 x 460 13
19990456 ● ● DN65 2" 2" DN65 114 305 454 520 x 410 x 460 20
19990457 ● ● ● ● DN65 2" 2" DN65 114 305 454 520 x 410 x 460 21
19990458 ● ● DN65 2" DN65 DN65 114 305 682 830 x 430 x 620 36
19990459 ● ● ● ● DN65 2" DN65 DN65 114 305 682 830 x 430 x 620 37
19990016 ( MB... 405 ) ● ● ● ● ● 3/4" 72 210 204 310 x 210 x 350 5
19990020 ( MB... 407 ) ● ● ● ● ● 3/4" 72 210 204 310 x 210 x 350 5
19990024 ( MB... 410 ) ● ● ● ● ● 1"1/4 95 260 249 310 x 210 x 350 8
19990168 ( MB... 412 ) ● ● ● ● ● 1"1/4 95 260 249 310 x 210 x 350 8
19990404 ( MB... 415 ) ● ● ● ● ● 1"1/2 103 270 311 520 x 410 x 460 11
19990405 ( MB... 420 ) ● ● ● ● ● 2" 114 330 367 520 x 410 x 460 13
19990410 ( MB... 412 ) ● ● ● ● ● 1"1/4 103 260 255 520 x 410 x 460 9
19990411 ( MB... 410 ) ● ● ● ● ● 1"1/4 103 260 255 520 x 410 x 460 9
19990454 ( MB... 415 ) ● ● ● ● ● ● ● 1"1/2 103 270 311 520 x 410 x 460 12
19990455 ( MB... 420 ) ● ● ● ● ● ● ● 2" 114 330 367 520 x 410 x 460 14
Gas train structure and composition
VL2
VPS
R VS Pmin FLDU
Pct
PICTURE B2
PICTURE B4
C
B2
B1
VL2 VS PminPmax RFLDU Pct
B2
B1
C
B2
Gas train part no.Gas train dimensions
mmB1 B2 C
Size of packagingmm
L x P x HPosition
F LDU Pct Pmin R VL2 VPS VS øWeight
kg
Gas train part no.Gas train dimensions
mmB1 B2 C
Size of packagingmm
L x P x HPosition
LDU Pct Pmax Pmin RF VL2 VS øWeight
kg
B4
CTV - Valve tightness controlF - FilterLDU - LDU valve tightness controlPct - Pressure switch for gas controlPmax - Maximum pressure switch Pmc - Minimum and control pressure switch
gas leaks
Pmin - Minimum pressure switchR - Pressure regulatorRF - Pressure regulator with filterRFP - Pressure regulator with filter
for pilot gas trainRM - Manual flow rate regulator
RP - Pneumatic regulatorVF - Regulator throttle valveVL - Operating valveVL2 - Two-stage operating valveVLP - Operating pilot valveVP - Pilot valve
VPS - VPS valve tightness controlVS - Safety valveVSP - Safety pilot valveØ - Gas train diameterØ1 - Main gas train diameterØ2 - Pilot gas train diameter
Legend
171171
19990460 ● ● DN65 DN65 1”1/2 DN65 DN65 207 295 969 1260 x 660 x 670 63
19990461 ● ● ● ● DN65 DN65 1”1/2 DN65 DN65 207 295 969 1260 x 660 x 670 64
19990462 ● ● DN80 DN80 1”1/2 DN80 DN80 210 320 1016 1320 x 690 x 670 97
19990463 ● ● ● ● DN80 DN80 1”1/2 DN80 DN80 210 320 1016 1320 x 690 x 670 98
19990465 ● ● ● ● DN100 DN100 1”1/2 DN100 DN100 242 385 1125 1320 x 690 x 670 104
Gas train structure and composition
PminPmax VL LDU Pct VS RF
VP
B1
C
B2
B5
Gas train part no.Gas train dimensions
mmB1 B2 C
Size of packagingmm
L x P x HPosition
LDU Pct Pmax Pmin RF VL VP VS øWeight
kg
PICTURE B5
VL2 VS PminPmax LDU Pct
PICTURE BE4
B2
B1
C
BE4
Gas train part no.Gas train dimensions
mmB1 B2 C
Size of packagingmm
L x P x HPosition
LDU Pct Pmax Pmin VL2 VS øWeight
kg
19990436 ● ● ● ● 3/4" 3/4" 3/4" 72 235 256 520 x 410 x 460 11
19990438 ● ● ● ● 1" 1" 1" 83 235 296 520 x 410 x 460 13
19990456 ● ● 2" 2" 2" 114 305 454 520 x 410 x 460 20
19990457 ● ● ● ● 2" 2" 2" 114 305 454 520 x 410 x 460 21
19990458 ● ● 2" DN65 DN65 114 305 682 830 x 430 x 620 36
19990459 ● ● ● ● 2" DN65 DN65 114 305 682 830 x 430 x 620 37
CTV - Valve tightness controlF - FilterLDU - LDU valve tightness controlPct - Pressure switch for gas controlPmax - Maximum pressure switch Pmc - Minimum and control pressure switch
gas leaks
Pmin - Minimum pressure switchR - Pressure regulatorRF - Pressure regulator with filterRFP - Pressure regulator with filter
for pilot gas trainRM - Manual flow rate regulator
RP - Pneumatic regulatorVF - Regulator throttle valveVL - Operating valveVL2 - Two-stage operating valveVLP - Operating pilot valveVP - Pilot valve
VPS - VPS valve tightness controlVS - Safety valveVSP - Safety pilot valveØ - Gas train diameterØ1 - Main gas train diameterØ2 - Pilot gas train diameter
Legend
172
VL R VS FVFCTV
Pmc
D2
PICTURE D2
172
Gas train structure and composition
PminPmax VL LDU Pct VS
VP
B1
C
B2
C
B2
B1
BE5
Gas train part no.Gas train dimensions
mmB1 B2 C
Size of packagingmm
L x P x HPosition
LDU Pct Pmax Pmin VL VP VS øWeight
kg
PICTURE BE5
19990460 ● ● DN65 1"1/2 DN65 DN65 207 295 969 1260 x 660 x 670 63
19990461 ● ● ● ● DN65 1"1/2 DN65 DN65 207 295 969 1260 x 660 x 670 64
19990462 ● ● DN80 1"1/2 DN80 DN80 210 320 1016 1320 x 690 x 670 97
19990463 ● ● ● ● DN80 1"1/2 DN80 DN80 210 320 1016 1320 x 690 x 670 98
19990464 ● ● DN100 1"1/2 DN100 DN100 242 385 1125 1320 x 690 x 670 103
19990465 ● ● ● ● DN100 1"1/2 DN100 DN100 242 385 1125 1320 x 690 x 670 104
CTV - Valve tightness controlF - FilterLDU - LDU valve tightness controlPct - Pressure switch for gas controlPmax - Maximum pressure switch Pmc - Minimum and control pressure switch
gas leaks
Pmin - Minimum pressure switchR - Pressure regulatorRF - Pressure regulator with filterRFP - Pressure regulator with filter
for pilot gas trainRM - Manual flow rate regulator
RP - Pneumatic regulatorVF - Regulator throttle valveVL - Operating valveVL2 - Two-stage operating valveVLP - Operating pilot valveVP - Pilot valve
VPS - VPS valve tightness controlVS - Safety valveVSP - Safety pilot valveØ - Gas train diameterØ1 - Main gas train diameterØ2 - Pilot gas train diameter
Legend
Gas train part no.Gas train dimensions
mmB1 B2 C
Size of packagingmm
L x P x HPosition
F CTV Pmc R VF VL VS øWeight
kg
19990500 ( MB... 410 ) ● ● ● ● DK32 ● ● 1”1/4 103 162 385 650 x 500 x 380 15
19990501 ( MB... 412 ) ● ● ● ● DK32 ● ● 1”1/4 103 162 385 650 x 500 x 380 15
19990502 ( MB... 415 ) ● ● ● ● DK40 ● ● 1”1/2 103 170 430 650 x 500 x 380 18
19990503 ( MB... 420 ) ● ● ● ● DK50 ● ● 2” 114 220 445 650 x 500 x 380 20
19990504 ( VGD20.50 ) ● ● ● ● DK50 ● ● 2” 114 255 1080 990 x 300 x 500 24
19990505 ( VGD40.065 ) ● ● ● ● DK65 ● ● DN65 207 291 1225 1380 x 430 x 710 50
19990506 ( VGD40.080 ) ● ● ● ● DK80 ● ● DN80 210 298 1350 1380 x 430 x 710 57
173173
Gas train structure and composition
CTV - Valve tightness controlF - FilterLDU - LDU valve tightness controlPct - Pressure switch for gas controlPmax - Maximum pressure switch Pmc - Minimum and control pressure switch
gas leaks
Pmin - Minimum pressure switchR - Pressure regulatorRF - Pressure regulator with filterRFP - Pressure regulator with filter
for pilot gas trainRM - Manual flow rate regulator
RP - Pneumatic regulatorVF - Regulator throttle valveVL - Operating valveVL2 - Two-stage operating valveVLP - Operating pilot valveVP - Pilot valve
VPS - VPS valve tightness controlVS - Safety valveVSP - Safety pilot valveØ - Gas train diameterØ1 - Main gas train diameterØ2 - Pilot gas train diameter
Legend
PminPmax VL VS RFVF CTV
Pct
D4
PICTURE D4
Modello bruciatore CTV Pct Pmax Pmin RF VF VL VS ØGI 350 ME ● ● ● ● DN65 DK50 2" 2” DN65GI 510 ME ● ● ● ● DN80 DK65 DN65 DN65 DN80GI 1000 LX ME ● ● ● ● ● DK80 DN80 DN80 DN80
PminPmax VL VSVPS R F
RP
C
B2
B1
B1
C
B2
D3
Gas train part no.Gas train dimensions
mmB1 B2 C
Size of packagingmm
L x P x HPosition
F Pmax Pmin R RP VL VPS VS øWeight
kg
PICTURE D3
● - As standard; ▲ - As standard for burners with an output of more than 1200 kW.
19990440 ( MB... 407 ) ● ● ● ● ● ● 3/4" 72 160 354 400 x 300 x 280 619990441 ( MB... 412 ) ● ● ● ● ● ● 1"1/4 95 175 500 520 x 410 x 460 919990442 ( MB... 415 ) ● ● ● ● ● ▲ ● 1"1/2 103 185 643 650 x 500 x 380 1219990443 ( MB... 420 ) ● ● ● ● ● ▲ ● 2" 114 225 711 990 x 300 x 500 1319990444 ( MB... 425 ) ● ● ● ● ● ▲ ● 2" 114 291 951 990 x 300 x 500 1919990445 ( DMV... 5080 ) ● ● ● ● ● ▲ ● DN80 210 304 1430 1380 x 430 x 710 7019990446 ( DMV... 5100 ) ● ● ● ● ● ● ● DN100 242 375 1750 1380 x 430 x 710 8519990447 ( MB... 407 ) ● ● ● ● ● ● 3/4" 72 160 354 400 x 300 x 280 619990448 ( MB... 412 ) ● ● ● ● ● ● 1"1/4 95 175 500 520 x 410 x 460 919990449 ( MB... 415 ) ● ● ● ● ● ● ● 1"1/2 103 185 643 650 x 500 x 380 1219990450 ( MB... 420 ) ● ● ● ● ● ● ● 2" 114 225 711 990 x 300 x 500 1319990451 ( MB... 425 ) ● ● ● ● ● ● ● 2" 114 291 951 990 x 300 x 500 1919990452 ( DMV... 5080 ) ● ● ● ● ● ● ● DN80 210 304 1430 1380 x 430 x 710 70 19990453 ( DMV... 5100 ) ● ● ● ● ● ● ● DN100 242 375 1750 1380 x 430 x 710 8519990468 ( VGD40.065) ● ● ● ● ● ● ● ● DN65 118 380 1020 1380 x 430 x 710 3019990469 ( VGD40.080) ● ● ● ● ● ● ● ● DN80 132 387 1150 1380 x 430 x 710 3919990470 ( VGD40.100) ● ● ● ● ● ● ● ● DN100 145 397 1350 1380 x 430 x 710 50
GI 1000 LX
174174
Gas train structure and composition
Pmin PmaxVL LDU Pct VS RFVF
VPSVP
D5
PICTURE D5
Burner model LDU Pct Pmax Pmin RF VF VL VP VPS VS ØBGN 40 DSPGN ● ● 1"1/2 DK32 1" 1/2" 1"1/2 1"1/2BGN 60 DSPGN ● ● 2" DK32 1"1/2 3/4" 2" 2"BGN 100 DSPGN ● ● 2" DK40 2" 1" 2" 2"BGN 120 DSPGN ● ● 2" DK40 2" 1" 2" 2"BGN 150 DSPGN (27 mbar) ● ● ● ● DN65 DK40 2" 1” 1/2 2" DN65BGN 150 DSPGN (150 mbar) ● ● ● ● 1”1/2 DK32 1”1/2 3/4” 1”1/2 1”1/2BGN 200 DSPGN (37 mbar) ● ● ● ● DN80 DK50 2" 1"1/2 DN65 DN80BGN 200 DSPGN (150 mbar) ● ● ● ● 2” DK32 1"1/2 3/4" 1"1/2 2”BGN 250 DSPGN ● ● ● ● 2" DK50 2" 1" 2" 2"BGN 300 DSPGN ● ● ● ● DN65 DK50 2" 1"1/2 2" DN65BGN 350 DSPGN ● ● ● ● DN65 DK50 2" 1"1/2 2" DN65COMIST 72 DSPGM ● ● 2" DK40 2" 1" 2" 2"COMIST 122 DSPGM ● ● ● ● DN65 DK50 2" 1" 2" DN65COMIST 180 DSPGM ● ● ● ● DN80 DK50 2" 1"1/2 DN65 DN80COMIST 250 DSPGM ● ● ● ● DN65 DK50 2" 1"1/2 DN65 DN65COMIST 300 DSPGM ● ● ● ● DN65 DK50 2" 1"1/2 DN65 DN65COMIST 180 DSPNM ● ● ● ● DN80 DK50 2" 1"1/2 DN65 DN80COMIST 250 DSPNM ● ● ● ● DN65 DK50 2" 1"1/2 DN65 DN65COMIST 300 DSPNM ● ● ● ● DN65 DK50 2" 1"1/2 DN65 DN65GI 350 DSPGN ● ● ● ● DN65 DK50 2" 1"1/2 DN65 DN65GI 420 DSPGN ● ● ● ● DN80 DK65 DN65 1"1/2 DN65 DN80GI 510 DSPGN ● ● ● ● DN80 DK80 DN80 1"1/2 DN80 DN80GI MIST 350 DSPGM ● ● ● ● DN65 DK50 2" 1"1/2 DN65 DN65GI MIST 420 DSPGM ● ● ● ● DN80 DK65 DN65 1"1/2 DN65 DN80GI MIST 510 DSPGM ● ● ● ● DN80 DK80 DN80 1"1/2 DN80 DN80GI MIST 350 DSPNM ● ● ● ● DN65 DK50 2" 1"1/2 DN65 DN65GI MIST 420 DSPNM ● ● ● ● DN80 DK65 DN65 1"1/2 DN65 DN80GI MIST 510 DSPNM ● ● ● ● DN80 DK80 DN80 1"1/2 DN80 DN80
CTV - Valve tightness controlF - FilterLDU - LDU valve tightness controlPct - Pressure switch for gas controlPmax - Maximum pressure switch Pmc - Minimum and control pressure switch
gas leaks
Pmin - Minimum pressure switchR - Pressure regulatorRF - Pressure regulator with filterRFP - Pressure regulator with filter
for pilot gas trainRM - Manual flow rate regulator
RP - Pneumatic regulatorVF - Regulator throttle valveVL - Operating valveVL2 - Two-stage operating valveVLP - Operating pilot valveVP - Pilot valve
VPS - VPS valve tightness controlVS - Safety valveVSP - Safety pilot valveØ - Gas train diameterØ1 - Main gas train diameterØ2 - Pilot gas train diameter
Legend
Modello bruciatore CTV Pct Pmax Pmin VF VL VS ØGI 350 ME ● ● ● ● DK50 2" 2” 2”GI 510 ME ● ● ● ● DK65 DN65 DN65 DN65
PminPmax VL VSVF CTV
Pct
DE4
PICTURE DE4
175175
Gas train structure and composition
Pmin PmaxVL LDU Pct VSVF
VPSVP
DE5
PICTURE DE5
Burner model LDU Pct Pmax Pmin VF VL VP VPS VS ØBGN 40 DSPGN ● ● DK32 1" 1/2" 1"1/2 1"1/2BGN 60 DSPGN ● ● DK32 1"1/2 3/4" 2" 2"BGN 100 DSPGN ● ● DK40 2" 1" 2" 2"BGN 120 DSPGN ● ● DK40 2" 1" 2" 2"BGN 150 DSPGN (22 mbar) ● ● ● ● DK40 2" 1” 1/2 2" 2"BGN 150 DSPGN (50 mbar) ● ● ● ● DK32 1”1/2 3/4” 1”1/2 1”1/2BGN 200 DSPGN (28 mbar) ● ● ● ● DK50 2" 1"1/2 DN65 DN65BGN 200 DSPGN (100 mbar) ● ● ● ● DK32 1"1/2 3/4" 1"1/2 1”1/2BGN 250 DSPGN ● ● ● ● DK50 2" 1" 2" 2"BGN 300 DSPGN ● ● ● ● DK50 2" 1"1/2 2" 2"BGN 350 DSPGN ● ● ● ● DK50 2" 1"1/2 2" 2"COMIST 72 DSPGM ● ● DK40 2" 1" 2" 2"COMIST 122 DSPGM ● ● ● ● DK50 2" 1" 2" 2"COMIST 180 DSPGM ● ● ● ● DK50 2" 1"1/2 DN65 DN65COMIST 250 DSPGM ● ● ● ● DK50 2" 1"1/2 DN65 DN65COMIST 300 DSPGM ● ● ● ● DK50 2" 1"1/2 DN65 DN65COMIST 180 DSPNM ● ● ● ● DK50 2" 1"1/2 DN65 DN65COMIST 250 DSPNM ● ● ● ● DK50 2" 1"1/2 DN65 DN65COMIST 300 DSPNM ● ● ● ● DK50 2" 1"1/2 DN65 DN65GI 350 DSPGN ● ● ● ● DK50 2" 1"1/2 DN65 DN65GI 420 DSPGN ● ● ● ● DK65 DN65 1"1/2 DN65 DN65GI 510 DSPGN ● ● ● ● DK80 DN80 1"1/2 DN80 DN80GI MIST 350 DSPGM ● ● ● ● DK50 2" 1"1/2 DN65 DN65GI MIST 420 DSPGM ● ● ● ● DK65 DN65 1"1/2 DN65 DN65GI MIST 510 DSPGM ● ● ● ● DK80 DN80 1"1/2 DN80 DN80GI MIST 350 DSPNM ● ● ● ● DK50 2" 1"1/2 DN65 DN65GI MIST 420 DSPNM ● ● ● ● DK65 DN65 1"1/2 DN65 DN65GI MIST 510 DSPNM ● ● ● ● DK80 DN80 1"1/2 DN80 DN80
CTV - Valve tightness controlF - FilterLDU - LDU valve tightness controlPct - Pressure switch for gas controlPmax - Maximum pressure switch Pmc - Minimum and control pressure switch
gas leaks
Pmin - Minimum pressure switchR - Pressure regulatorRF - Pressure regulator with filterRFP - Pressure regulator with filter
for pilot gas trainRM - Manual flow rate regulator
RP - Pneumatic regulatorVF - Regulator throttle valveVL - Operating valveVL2 - Two-stage operating valveVLP - Operating pilot valveVP - Pilot valve
VPS - VPS valve tightness controlVS - Safety valveVSP - Safety pilot valveØ - Gas train diameterØ1 - Main gas train diameterØ2 - Pilot gas train diameter
Legend
176176
Gas train structure and composition
Pmin Pmax
Pmin Pmax
VL LDU VS RFVF Pct
VLP VSP RFP
D6
PICTURE D6
Burner model LDU Pct Pmax Pmin RF RFP VF VL VLP VS VSP Ø1 Ø2
GI 1000 DSPGN ● ● ● ● DN100 1/2" DK80 DN80 1/2" DN80 1/2" DN100 1/2"
GI MIST 1000 DSPGM ● ● ● ● DN100 1/2" DK80 DN80 1/2" DN80 1/2" DN100 1/2"
GI MIST 1000 DSPNM ● ● ● ● DN100 1/2" DK80 DN80 1/2" DN80 1/2" DN100 1/2"
Pmin Pmax
Pmin Pmax
VL LDU VSVF Pct
VLP VSP
DE6
PICTURE DE6
Burner model LDU Pct Pmax Pmin VF VL VLP VS VSP Ø1 Ø2
GI 1000 DSPGN ● ● ● ● DK80 DN80 1/2" DN80 1/2" DN80 1/2"
GI MIST 1000 DSPGM ● ● ● ● DK80 DN80 1/2" DN80 1/2" DN80 1/2"
GI MIST 1000 DSPNM ● ● ● ● DK80 DN80 1/2" DN80 1/2" DN80 1/2"
CTV - Valve tightness controlF - FilterLDU - LDU valve tightness controlPct - Pressure switch for gas controlPmax - Maximum pressure switch Pmc - Minimum and control pressure switch
gas leaks
Pmin - Minimum pressure switchR - Pressure regulatorRF - Pressure regulator with filterRFP - Pressure regulator with filter
for pilot gas trainRM - Manual flow rate regulator
RP - Pneumatic regulatorVF - Regulator throttle valveVL - Operating valveVL2 - Two-stage operating valveVLP - Operating pilot valveVP - Pilot valve
VPS - VPS valve tightness controlVS - Safety valveVSP - Safety pilot valveØ - Gas train diameterØ1 - Main gas train diameterØ2 - Pilot gas train diameter
Legend
177177
Gas train structure and composition
VL LDU Pct PmaxPminVS
B2
B1
C
ME4
Gas train part no.Gas train dimensions
mmB1 B2 C
Size of packagingmm
L x P x HPosition
LDU Pct Pmax Pmin VL VS øWeight
kg
PICTURE ME4
PICTURE M2
19990062 ● ● 1”1/2 1”1/2 1”1/2 103 205 390 520 x 410 x 460 12
VL VPS R VS Pmin F
C
B2
B1
M2
Gas train part no.Gas train dimensions
mmB1 B2 C
Size of packagingmm
L x P x HPosition
F Pmin R VL VPS VS øWeight
kg
19990002 ( MB... 405 ) ● ● ● ● ● 3/4" 72 150 204 310 x 210 x 250 4
19990005 ( MB... 407 ) ● ● ● ● ● 3/4" 72 150 204 310 x 210 x 250 4
19990008 ( MB... 410 ) ● ● ● ● ● 1"1/4 95 162 249 310 x 210 x 250 7
19990166 ( MB... 412 ) ● ● ● ● ● 1"1/4 95 162 249 310 x 210 x 250 7
19990332 ( MB... 405 ) ● ● ● ● ● ● 3/4" 72 150 204 310 x 210 x 250 5
19990338 ( MB... 403 ) ● ● ● ● ● 1/2" 67 150 198 210 x 150 x 160 2
PICTURE M2
VL2 Pmin
B2
B1
C
ME1
Gas train part no.Gas train dimensions
mmB1 B2 C
Size of packagingmm
L x P x HPosition
Pmin VL øWeight
kg
PICTURE ME1
19990004 ● 3/4" 3/4" 72 177 114 240 x 220 x 210 3
19990134 ● 1" 1" 83 177 160 240 x 220 x 210 4
19990143 ● 1/2" 1/2" 66 123 94 240 x 220 x 210 2
19990235 ● 1/2" 1/2" 72 151 110 240 x 220 x 210 2
CTV - Valve tightness controlF - FilterLDU - LDU valve tightness controlPct - Pressure switch for gas controlPmax - Maximum pressure switch Pmc - Minimum and control pressure switch
gas leaks
Pmin - Minimum pressure switchR - Pressure regulatorRF - Pressure regulator with filterRFP - Pressure regulator with filter
for pilot gas trainRM - Manual flow rate regulator
RP - Pneumatic regulatorVF - Regulator throttle valveVL - Operating valveVL2 - Two-stage operating valveVLP - Operating pilot valveVP - Pilot valve
VPS - VPS valve tightness controlVS - Safety valveVSP - Safety pilot valveØ - Gas train diameterØ1 - Main gas train diameterØ2 - Pilot gas train diameter
Legend
178178
BTL 14 166 166 170 170 M10 135
BTL 14P 166 166 170 170 M10 135
BTL 20 185 185 170 170 M10 135
BTL 20P 185 185 170 170 M10 135
BTL 26 185 185 170 170 M10 140
BTL 26P 185 185 170 170 M10 140
SPARK 35 215 215 200 245 M12 165
SPARK 35 W 215 215 200 245 M12 165
SPARK 35 DSG 215 215 200 245 M12 165
SPARK 35 DSGW 215 215 200 245 M12 165
BT 40 G 215 215 200 245 M12 165
BT 40 DSG 215 215 200 245 M12 170
BT 55 DSG 215 215 200 245 M12 170
BTL 3 170 144 135 161 M8 85
BTL 3H 170 144 135 161 M8 85
BTL 0 170 140 130 155 M8 85
BTL 0H 170 140 130 155 M8 85
BTL 4 170 140 130 155 M8 85
BTL 4H 170 140 130 155 M8 85
BTL 4P 170 140 130 155 M8 85
BTL 6 170 140 130 155 M8 95
BTL 6H 170 140 130 155 M8 95
BTL 6P 170 140 130 155 M8 95
BTL 10 170 140 130 155 M8 95
BTL 10H 170 140 130 155 M8 95
BTL 10P 170 140 130 155 M8 95
Boiler connection flangeLIGHT OIL BURNERS
Model I I1 L M Nmin max
Model I I1 L M Nmin max
Model I I1 L M N
BT 60 G 290 - 233 M12 195
BT 75 DSG/3V 290 - 233 M12 180
BT 75 DSPG 290 - 233 M12 180
BT 100 DSG 320 - 276 M16 240
BT 100 DSPG 320 - 276 M16 240
BT 120 DSG/3V 320 - 276 M16 240
BT 120 DSPG 320 - 276 M16 240
BT 180 DSG/3V 400 - 339 M16 270
BT 180 DSPG 400 - 339 M16 270
BT 250 DSG 400 - 339 M16 270
BT 250 DSPG 400 - 339 M16 270
Model I I2 I3 L M Nmin max
BT 300 DSG 550 260 290 480 480 M20 380
BT 300 DSPG 550 260 290 480 480 M20 380
BT 350 DSG 550 260 290 480 480 M20 380
BT 350 DSPG 550 260 290 480 480 M20 380
179179
RINOX 190 L2 166 166 150 200 M10 110
SPARK 35 LX 215 215 200 245 M12 150
BT 40 LX 215 215 200 245 M12 150
Boiler connection flange
Model I I2 I3 L M Nmin max
GI 350 DSPG 550 260 290 480 510 M20 380
Model I I1 L M Nmin max
RINOX 35 L 170 140 130 155 M8 85
RINOX 60 L 170 140 130 155 M8 95
RINOX 60 L2 170 140 130 155 M8 95
Model I I1 L M Nmin max
Model I I1 L M Nmin max
BT 75 LX 290 - 233 - M12 170
Model I I1 L M N
GI 420 DSPG 580 - 520 M20 420
GI 510 DSPG 580 - 520 M20 420
Model I I1 L M N
GI 1000 DSPG 800 - 765 M16 495
LIGHT OIL BURNERS
Model I I1 L M N
BT 40 DSG Hinged 280 280 325 M12 170
BT 55 DSG Hinged 280 280 325 M12 170
BT 75 DSG 3V Hinged 280 280 325 M12 220
BT 100 DSG Hinged 300 300 340 M16 240
BT 120 DSG 3V Hinged 300 300 340 M16 240
BT 180 DSG 3V Hinged 340 340 396 M16 275
BT 250 DSG Hinged 340 340 396 M16 275
BT 300 DSG Hinged 430 430 509 M18 370
BT 350 DSG Hinged 430 430 509 M18 370
180180
GI 350 DSPN-D 550 260 290 480 510 M20 380
BT 300 DSN 4T 550 260 290 480 510 M20 380
BT 300 DSNM-D 550 260 290 480 510 M20 380
BT 300 DSPN 550 260 290 480 510 M20 380
BT 350 DSN 4T 550 260 290 480 510 M20 380
BT 350 DSNM-D 550 260 290 480 510 M20 380
BT 350 DSPN 550 260 290 480 510 M20 380
BT 75 DSN 4T 290 - 233 M12 180
BT 75 DSNM-D 290 - 233 M12 180
BT 75 DSPN 290 - 233 M12 180
BT 100 DSN 4T 320 - 276 M16 240
BT 100 DSNM-D 320 - 276 M16 240
BT 100 DSPN 320 - 276 M16 240
BT 120 DSN 4T 320 - 276 M16 240
BT 120 DSNM-D 320 - 276 M16 240
BT 120 DSPN 320 - 276 M16 240
BT 180 DSN 4T 400 - 339 M16 270
BT 180 DSNM-D 400 - 339 M16 270
BT 180 DSPN 400 - 339 M16 270
BT 250 DSN 4T 400 - 339 M16 270
BT 250 DSNM-D 400 - 339 M16 270
BT 250 DSPN 400 - 339 M16 270
Boiler connection flangeHEAVY OIL BURNERS
Model I I1 L M N
Model I I2 I3 L M Nmin max
BT 15 N 240 - 184 M12 130
BT 17 SPN 240 - 184 M12 145
BT 22 N 240 - 184 M12 145
Model I I1 L M N
BT 35 N 215 215 200 245 M12 165
BT 35 SPN 215 215 200 245 M12 165
BT 40 DSN 4T 215 215 200 245 M12 165
BT 50 DSN 4T 215 215 200 245 M12 165
Model I I1 L M Nmin max
Model I I2 I3 L M Nmin max
Model I I1 L M N
BT 40 DSN 4T Hinged 280 280 325 M12 170
BT 55 DSN 4T Hinged 280 280 325 M12 170
BT 75 DSN 4T Hinged 280 280 325 M12 220
BT 100 DSN 4T Hinged 300 300 340 M16 240
BT 120 DSN 4T Hinged 300 300 340 M16 240
BT 180 DSN 4T Hinged 340 340 396 M16 275
BT 250 DSN 4T Hinged 340 340 396 M16 275
BT 300 DSN 4T Hinged 430 430 509 M18 370
BT 350 DSN 4T Hinged 430 430 509 M18 370
181181
Boiler connection flange
Model I I1 L M Nmin max
BTG 3 170 144 135 161 M8 95
BTG 3,6 170 140 130 155 M8 95
BTG 3,6 P 170 140 130 155 M8 95
BTG 6 170 140 130 155 M8 95
BTG 6 P 170 140 130 155 M8 95
BTG 11 170 140 130 155 M8 95
BTG 11 P 170 140 130 155 M8 95
Model I I1 L M Nmin max
Model I I1 L M N
BTG 20 185 185 170 210 M10 120
BTG 20P 185 185 170 210 M10 120
SPARKGAS 30 215 215 200 245 M12 150
SPARKGAS 30 W 215 215 200 245 M12 150
SPARKGAS 30 P 215 215 200 245 M12 150
SPARKGAS 30 PW 215 215 200 245 M12 150
SPARKGAS 35 215 215 200 245 M12 150
SPARKGAS 35 W 215 215 200 245 M12 150
SPARKGAS 35 P 215 215 200 245 M12 150
SPARKGAS 30 PW 215 215 200 245 M12 150
BGN 40 P 215 215 200 245 M12 165
BGN 40 DSPGN 215 215 200 245 M12 165
BGN 40 DSPGN ME 215 215 200 245 M12 165
BGN 50 215 215 200 245 M12 180
BGN 60 P 290 - 233 M12 190
BGN 60 DSPGN 290 - 233 M12 190
BGN 60 DSPGN ME 290 - 233 M12 190
BGN 100 P 290 - 233 M12 190
BGN 100 DSPGN 290 - 233 M12 190
BGN 100 DSPGN ME 290 - 233 M12 190
BGN 120 P 320 - 276 M16 220
BGN 120 DSPGN 320 - 276 M16 220
BGN 120 DSPGN ME 320 - 276 M16 220
BGN 150 P 320 - 276 M16 220
BGN 150 DSPGN 320 - 276 M16 220
BGN 150 DSPGN ME 320 - 276 M16 220
BGN 200 P 400 - 339 M16 240
BGN 200 DSPGN 400 - 339 M16 240
BGN 200 DSPGN ME 400 - 339 M16 240
BGN 250 P 400 - 339 M16 240
BGN 250 DSPGN 400 - 339 M16 240
BGN 250 DSPGN ME 400 - 339 M16 240
GAS BURNERS
Model I I1 L M N
GI 420 DSPN-D 580 - 520 M20 420
GI 510 DSPN-D 580 - 520 M20 420
Model I I1 L M N
GI 1000 DSPN-D 800 - 765 M16 495
HEAVY OIL BURNERS
182182
BGN 60 LX 320 - 150 170 290 M12 225 12 67,5 80,5
BGN 60 LX V 320 - 150 170 290 M12 225 12 67,5 80,5
BGN 120 LX 365 - 175 190 330 M16 265 12 62,5 108
BGN 120 LX V 365 - 175 190 330 M16 265 12 62,5 108
BGN 200 LX 440 - 205 230 410 M16 330 12 78 135
BGN 200 LX V 440 - 205 230 410 M16 330 12 78 135
BGN 300 LX 550 - 260 290 480 510 M20 350 12 87 150,5
BGN 300 LX V 550 - 260 290 480 510 M20 350 12 87 150,5
BGN 390 LX 550 - 260 290 480510 M20 350 12 87 150,5
BGN 390 LX V 550 - 260 290 480 510 M20 350 12 87 150,5
Boiler connection flange
Model I I2 I3 L M Nmin max
BGN 300 P 550 260 290 480 510 M20 340
BGN 300 DSPGN 550 260 290 480 510 M20 340
BGN 300 DSPGN ME 550 260 290 480 510 M20 340
BGN 350 P 550 260 290 480 510 M20 390
BGN 350DSPGN 550 260 290 480 510 M20 390
BGN 350DSPGN ME 550 260 290 480 510 M20 390
GI 350 DSPGN 540 - 480 M20 375
GI 350 DSPGN ME 540 - 480 M20 375
GI 420 DSPGN 580 - 520 M20 420
GI 510 DSPGN 580 - 520 M20 420
GI 510 DSPGN ME 580 - 520 M20 420
GI 1000 LX ME 685 - 630 M16 495
GAS BURNERS
Model I I1 I2 I3 L M N Z Z1 Z2min max
BTG 20 LX 185 185 - - 170 210 M10 120 12 30,2 64,8
SPARKGAS 30 LX 215 215 - - 200 245 M12 180 12 42,5 73,6
SPARKGAS 30 LX V 215 215 - - 200 245 M12 180 12 42,5 73,6
BGN 40 LX 215 215 - - 200 245 M12 180 12 42,5 73,6
BGN 40 LX V 215 215 - - 200 245 M12 180 12 42,5 73,6
Model I I1 I2 I3 L M N Z Z1 Z2min max
BGN 540 LX 580 - - - 520 M20 430 12 131 156
BGN 540 LX V 580 - - - 520 M20 430 12 131 156
Model I I1 I2 I3 L M N Z Z1 Z2min max
GI 1000 LX 685 - - - 630 M16 495 12 260 65
GI 1000 LX V 685 - - - 630 M16 495 12 260 65
Model I I1 I2 I3 L M N Z Z1 Z2min max
Model I I1 L M N
Model I I1 L M N
183183
GI MIST 350 DSPGM 540 - 480 M20 375
GI MIST 350 DSPNM 540 - 480 M20 375
GI MIST 420 DSPGM 580 - 520 M20 420
GI MIST 420 DSPNM 580 - 520 M20 420
GI MIST 510 DSPGM 580 - 520 M20 420
GI MIST 510 DSPNM 580 - 520 M20 420
COMIST 20 185 185 170 210 M10 135
COMIST 26 SP 185 185 170 210 M10 140
COMIST 36 235 235 255 M12 175
Boiler connection flangeDUAL FUEL BURNERS
Model I I1 L M Nmin max
MINICOMIST 7 170 - 130 155 M8 115
MINICOMIST 11 170 - 130 155 M8 115
Model I I1 L M Nmin max
Model I I1 L M N
COMIST 180 460 - 400 M20 300
COMIST 180 NM 460 - 400 M20 300
COMIST 180 DSPGM 460 - 400 M20 300
COMIST 180 DSPNM 460 - 400 M20 300
Model I I2 I3 L M Nmin max
COMIST 250 550 260 290 480 510 M20 340
COMIST 250 NM 550 260 290 480 510 M20 340
COMIST 250 DSPGM 550 260 290 480 510 M20 340
COMIST 250 DSPNM 550 260 290 480 510 M20 340
COMIST 300 550 260 290 480 510 M20 340
COMIST 300 NM 550 260 290 480 510 M20 340
COMIST 300 DSPGM 550 260 290 480 510 M20 340
COMIST 300 DSPNM 550 260 290 480 510 M20 340
Model I I1 L M N
Model I I1 L M N
GI MIST 1000 DSPGM 685 - 630 M16 495
GI MIST 1000 DSPNM 685 - 630 M16 495
Model I I1 L M N
COMIST 72 320 - 276 M16 205
COMIST 72 N 320 - 276 M16 205
COMIST 72 DSPGM 400 - 339 M16 240
COMIST 122 400 - 339 M16 240
COMIST 122 N 400 - 339 M16 240
COMIST 122 DSPGM 400 - 339 M16 240
Data reported in this brochure shall be considered as indicative; Baltur reserves the right to change them without previous notice.
BALTUR S.p.A.Via Ferrarese, 10
44042 Cento (FE) - Italy
Tel. +39.051.684.37.11
Fax +39.051.685.75.27/28
www.baltur.com