© 2006 ibm corporation xseries and bladecenter xseries technical support cristian giacci ibm...

17
© 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross Italia S.p.A.

Upload: alaina-little

Post on 17-Dec-2015

223 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: © 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross

© 2006 IBM Corporation

xSeries and BladeCenterxSeries Technical Support

CRISTIAN GIACCI IBM eServer xSeries Sales & Technical SpecialistComputer Gross Italia S.p.A.

Page 2: © 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross

© 2006 IBM Corporation

IBM Systems Group

Sca

le u

p /

SM

P c

om

pu

tin

g

Scale out / distributed computing

BladeCenterx336

tended Design Architecturetended Design Architecture

x346

x226x236

x306m

x366

Clusters andvirtualization

High density

Large symmetrical multiprocessing (SMP)

e326

x206m

x460

Cluster 1350

xSeries portfolio leads in the industry

x260

x100

eServer 326m

Page 3: © 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross

© 2006 IBM Corporation

IBM Systems Group

LinuxSuse

Appl2

Win2000

Appl3

LinuxRH

Appl4

WinNT 4

Appl1

Win2003

Appl5

LinuxDebian

Appl6

LinuxSuse

Appl7

Win2000

Appl8

LinuxRH

Appl9

We don’t see this 1_Appl–1_OS limitation changing any soon....

.... but we can change the system infrasctructure to support it

..and so on...

..and so on...

Common Intel landscapeCommon Intel landscape

Page 4: © 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross

© 2006 IBM Corporation

IBM Systems Group

LinuxSuse

Appl2

Win2000

Appl3

LinuxRH

Appl4

WinNT 4

Appl1

Win2003

Appl5

LinuxDebian

Appl6

LinuxSuse

Appl7

Win2000

Appl8

LinuxRH

Appl9

ethernetSAN

bladecenter

..and so on...

Evoluzione

Page 5: © 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross

© 2006 IBM Corporation

Blades offering

Page 6: © 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross

© 2006 IBM Corporation

IBM Systems Group

Layer 2 Switches

SSL Appliances

Caching Appliances

Storage Fibre

Switches

Storage Fibre

Switches

SSL Appliances

Caching Appliances

Layer 4-7 Switches

Public Internet/Intranet Clients

Routers (Layer 3

Switches)

Firewalls

Storage Area

Network

Step 1Consolidate ServersStep 2Integrate First Layerof the Network (L2)

Storage Fibre

Switches

Storage Fibre

Switches

Storage Area

Network

Layer 2 Switches

SSL Appliances

Caching Appliances

SSL Appliances

Caching Appliances

Layer 4-7 Switches

Public Internet/Intranet Clients

Routers (Layer 3

Switches)

Firewalls

Step 3Integrate Storage Fabric

Storage Fibre

Switches

Storage Fibre

Switches

Storage Area

Network

SSL Appliances

Caching Appliances

SSL Appliances

Caching Appliances

Layer 4-7 Switches

Public Internet/Intranet Clients

Routers (Layer 3

Switches)

Firewalls

Step 4Integrate Second Layerof the Network (L4-7)

Storage Area

Network

SSL Appliances

Caching Appliances

SSL Appliances

Caching Appliances

Layer 4-7 Switches

Public Internet/Intranet Clients

Routers (Layer 3

Switches)

Firewalls

Step 5Consolidate Applications

Storage Area

Network

Public Internet/Intranet Clients

Routers (Layer 3

Switches)

Firewalls

SSL Appliances

Caching Appliances

SSL Appliances

Caching Appliances

Storage Area

Network

Public Internet/Intranet Clients

Routers (Layer 3

Switches)

Firewall

ResultBladeCenterCollapses Complexity

Page 7: © 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross

© 2006 IBM Corporation

IBM Systems Group

BladeCenter Chassis - Front

►Up to 4 Processors / 4 Cores each Blade

►Up to 14 Blades each BladeCenter

►Up to 6 BC’s each Enterprise 42U Rack

►Hot-swap of PS’s, Blowers, Switches and Blades

►Hot-swap switchable Media tray (DVD-ROM, Floppy, USB 1.1)

►Dual midplane and double connections to Blades

Page 8: © 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross

© 2006 IBM Corporation

IBM Systems Group

What is a “Blade” A “server on a card” – each “Blade” has

its own:► processor► networking► memory► optional storage► etc.

The chassis provides shared:► Console Access (KVM)► Power Supplies► Cooling► Network Connectivity (SAN/LAN/Myrinet

Switches)► CD-ROM/DVD-ROM drive► diskette drive

IBM Blade - in its own rugged-ized chassis

IBM Blade - with its cover on - ready for insertion into the BladeCenter

IBM BladeCenter chassis - 7U rackable

Page 9: © 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross

© 2006 IBM Corporation

IBM Systems Group

BladeCenter Chassis - Rear

Ethernet Switch

Redundant BlowerKVM Switch /

Management ModuleRedundant Power

Gigabit Ethernet Switches (Layer 2-3)► D-Link, Cisco, Nortel

► Commodity level networking

► Link aggregation

► VLAN creation and management

Nortel Layer 2-7 Switch► Advanced networking

► Content-based routing

Fibre Channel Switches (2/4Gb FC Fabric)► Brocade, McData, Qlogic

► Potentially lower cost via integration

► Full support of FC-SW-2 standards

Power (4 x 2000W load-balancing)► Upgradeable as required

► Redundant and load balancing for high availability

Calibrated, vectored cooling™► Highly fault tolerant

► Status Monitoring/PFA

► Allow maximum processor speeds

KVM Switches / Management Modules► Full remote video redirection► In many cases out-of-band / lights out systems management

Nortel Layer 2-7 SwitchQLogic, MCData orBrocade 2/4Gb Fibre Channel Switch Module

Page 10: © 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross

© 2006 IBM Corporation

IBM Systems Group

ethernet

1. Director Console

3. Telnet Interface

4. Command Line Interface (MPCLI)

2. Web Interface

Page 11: © 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross

© 2006 IBM Corporation

IBM Systems Group

Integrated System Management Blade Center

Page 12: © 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross

© 2006 IBM Corporation

IBM Systems Group

What is about ?

BladeCenterBladeCenter T

Management Module

2-way Xeon2-way low voltage Xeon

2-socket Opteron2-way PowerPC

NortelCisco

QLogicBrocadeMcDataTopspin

Cisco 4X InfiniBand Switch Module (preannounce)

2-socket PowerPC Refresh (dual core)2-way low voltage Xeon speedbumps

2-way Xeon RoHS2-socket Opteron speed bump and RoHS

2-socket Sossaman (preannounce)

Blades

Chassis

Switches

AdaptersDual 4X InfiniBand HCA

Dual Gigabit EthernetDual iSCSI/TOE EthernetDual QLogic Fibre HBADual Emulex Fibre HBA

Dual Topspin 1X InfinibandDual Myrinet Fabric

Ecosystem

Base Additions

BladeCenter H

IBM BladeCenterAdvanced Management Module

The strength of the entire BladeCenter ecosystem – Includes 700 Alliance and OpenSpec Partners Blade.Org

CURRENT

THE FOUNDATION CONTINUES

NEW

Page 13: © 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross

© 2006 IBM Corporation

IBM Systems Group

Two socket AMD

Single- and dual- core

Similar feature set to HS20

32- or 64-bit HPC

High memory bandwidth applications

LS20 2-core AMD

Tar

get

Ap

ps

Fea

ture

s

HS20 2-core Xeon HS40 4-core Xeon

Common Chassis and Infrastructure

Intel Xeon MP processors

4-way SMP capability

Supports Windows®, Linux® and NetWare

Back-end workloads

Large mid-tier apps

Intel® Xeon™ DP

EM64T

Intel® Xeon™ dualcore 32bit

Mainstream rack dense blade

High availability apps

Optional HS HDD

Edge and mid-tier workloads

Collaboration

Web serving

JS21 4-core PPC

Dual-core PowerPC® 970MP Processor

Built-in virtualization1

Scalable UNIX® Blade

Integrated vector co-processor for high-performance parallel computing

HPC: life/earth sciences, AltiVec™2 acceleration

UNIX workloads (WebSphere®)

AIX 5L™ SCON

Portfolio breadth for customizing solutions

1. Must acquire optional VIOS license to utilize Micro-Partitioning™2. AltiVec is a trademark of Freescale Semiconductor, Inc.

Page 14: © 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross

© 2006 IBM Corporation

IBM Systems Group

IBM eServer BladeCenter HS20Full Performance and

Manageability you expect from 1U/2U/3U platforms...at TWICE the density!

• Up to two Xeon DP Processors with EAM64T• 2.4GHz, 2.80 GHz,

3.06GHz EM64T, 3.6GHz, 800MHz FSB

• Dual Gigabit Ethernet Channels

• Up to 8GB Chipkill ECC DDR Memory

• Integrated Systems Management Processor

• High Availability Midplane Connections

Server Processors...

for Server Workloads!

Page 15: © 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross

© 2006 IBM Corporation

IBM Systems Group

HS20 and BSE2 Architecture

New access door

Existing form factor daughter cards

BSE2

SFF SCSI HDDs

Memory (4x)

CPU 1

CPU 2

HS20

New SFF daughter card

OR New SFF daughter cards

New HS20 Two SFF SCSI drive bays standard and

One I/O Expansion Card slot standard Two SFF SCSI drives can coexist with

One SFF Expansion Card One SFF SCSI drive can coexist with

One legacy Expansion Card

New BladeCenter SCSI Expansion2 Two 3.5” hot-swappable HDD bays Two I/O Expansion Card connections

► 1st must be Gb Ethernet daughter card► 2nd connection is flexible ► Supports legacy Exp Cards and SFF DC

Note: current BSE (48P7058 or 26K4847) will not function with this blade. New BSE is not backward compatible with Laurel, McCarran or Arbuckle

Page 16: © 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross

© 2006 IBM Corporation

IBM Systems Group

Optical Pass-thru Module

Provide direct connectivity between server blade and external devices► Ethernet network devices► Fibre Channel network devices► Myrinet cluster switches

Page 17: © 2006 IBM Corporation xSeries and BladeCenter xSeries Technical Support CRISTIAN GIACCI IBM eServer xSeries Sales & Technical Specialist Computer Gross

© 2006 IBM Corporation

IBM Systems Group

Copper Pass-thru Module

Provide direct connectivity between server blade integrated ethernet adapter and external devices► Only 1Gb connection allowed► Requires cat-5e or above inteface cable