FACP FSCU VS WF FAA DH 2 E4.2 F FIRE ALARM PULL STATION. WALL MOUNTED WITH OPERABLE PART OF THE DEVICE AT 46" AFF. FIRE ALARM SIGNAL, SPEAKER AND FLASHING LIGHT, 80" AFF TO THE BOTTOM OF THE LINES. "C" DESIGNATION INDICATES CEILING MOUNTED. FIRE ALARM STROBE LIGHT, 80" AFF TO THE BOTTOM OF THE LENS. FIRE ALARM CONNECTION, HOOD EXTINGUISHING SYSTEM, SEE MECHANICAL DRAWINGS FOR LOCATION. INTERLOCK WITH SHUNT TRIP BREAKERS FOR EQUIPMENT UNDER HOOD. FIRE ALARM REMOTE LCD ANNUNCIATOR PANEL. FLUSH RECESSED WALL MOUNTED. FIRE ALARM DOOR HOLDER, WALL MOUNTED, CONSULT ARCHITECTURAL DRAWINGS TO DETERMINE TYPE REQUIRED. PROVIDE POWER FROM NEAREST RECEPTACLE CIRCUIT AND CONNECT TO FIRE ALARM SYSTEM. TAMPER SWITCH, FURNISHED AND INSTALLED WITH SPRINKLER SYSTEM. INTERLOCK WITH FIRE ALARM SYSTEM BY ELECTRICAL. FLOW SWITCH, FURNISHED AND INSTALLED WITH SPRINKLER SYSTEM. INTERLOCK WITH FIRE ALARM SYSTEM BY ELECTRICAL. FIRE ALARM SMOKE DETECTOR, CEILING MOUNTED. FIRE ALARM DUCT SMOKE DETECTOR LOCATED IN HVAC DUCT. FIRE ALARM CONTROL PANEL, SURFACE WALL MOUNTED. FIRE ALARM SIGNAL, HORN. 90" AFF TO THE TOP OF THE DEVICE. WEATHER PROOF. FIRE ALARM HEAT DETECTOR, 135 DEG, OPERATION. FIRE ALARM STROBE LIGHT, CEILING MOUNTED. S M FIRE ALARM: H S WP IC AD AC S 2. COORDINATE MOUNTING HEIGHTS, DEVICE LOCATIONS & POWER/CONTROL REQUIREMENTS WITH ARCHITECTURAL DRAWINGS AND SYSTEM INSTALLER. INTRUSION DETECTION SYSTEM: CONDUIT SLEEVE: NUMBER & SIZE, (2)-2" FOR ALL CLASSROOMS, (1)-2" FOR ALL OFFICES, UNO CABLE TRAY: SIZE AS INDICATED, 18"W x 4"H TYP. INTERCOM SPEAKER: WEATHERPROOF WALL MOUNTED AT 96"AFF. MICROPHONE JACK: WALL MOUNTED AT 18" AFF, UNO. PUSH BUTTON EMERGENCY CALL STATION: 46" AFF, UNO. ADMINISTRATIVE DISPLAY PHONE: WALL MOUNT AT 46" AFF INTRUSION SYSTEM: KEY-PAD, MOUNT 48"AFF INTRUSION DETECTION DEVICE: WALL MTD. ACCESS CONTROL SYSTEMS SEE DETAIL 2/T3.0 FOR POWER, POWER DISCONNECT, LOW VOLTAGE CABLING, BOXES AND CONDUIT REQUIREMENTS. REFER TO ARCHITECTURAL PLANS AND DOOR SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. INTERCOM SPEAKER: 2' X 2' SQUARE CEILING MOUNTED COORDINATE MOUNTING HEIGHTS, DEVICE LOCATIONS & POWER/CONTROL REQUIREMENTS WITH ARCHITECTURAL DRAWINGS AND SYSTEM INSTALLER. SPEAKER SYSTEM: CABLING COMPONENTS: THE CONTRACTOR SHALL PROVIDE ROUGH-IN FOR ALL DEVICES AND WIRING. ROUGH-IN REQUIREMENTS ARE SPECIFIED IN SECTION 261010. VERIFY ADJACENCY TO CORRESPONDING POWER RECEPTACLES. OTHER DEVICES WHOSE LOCATIONS ARE NOT DEPENDENT ON RECEPTACLE PLACEMENT SHALL BE COORDINATED WITH SYSTEM INSTALLER. WALL MTD. TELECOMMUNICATION JUNCTION BOX AND CONDUIT ROUGH-IN TO NEAREST ACCESSIBLE CEILING CEILING MTD. TELECOMMUNICATION JUNCTION BOX WALL MTD. TELECOMMUNICATION JUNCTION BOX AND CONDUIT ROUGH-IN TO NEAREST ACCESSIBLE CEILING CEILING MTD. TELECOMMUNICATION JUNCTION BOX AND CONDUIT ROUGH-IN TO NEAREST ACCESSIBLE CEILING WALL MTD. TELECOMMUNICATION JUNCTION BOX AND CONDUIT ROUGH-IN TO NEAREST ACCESSIBLE CEILING ROUGH-IN FOR LOW VOLTAGE SYSTEMS: K P PC XX-1 T M ABBREVIATIONS: LEGEND: LIGHTING FIXTURES: ELECTRICAL EQUIPMENT: GENERAL NOTES: BRANCH CIRCUITS: CONDUCTOR COUNTS ARE SHOWN ON THE HOMERUNS ONLY. CONTRACTOR SHALL DETERMINE COUNTS FOR INTERMEDIATE RUNS BASED ON THE MANNER IN WHICH THE CIRCUIT ELEMENTS ARE CONNECTED. REFER TO THE SPECIFICATION SECTIONS 262010, 262080, & 26030 FOR SPECIAL REQUIREMENTS. LA-1,3,5 SWITCH: MOTOR RATED, WITHOUT OVERLOAD PROTECTION DISCONNECT SWITCH DRY-TYPE TRANSFORMER PANELBOARD: SURFACE MOUNTED EQUIPMENT AS NOTED, SEE ABBREVIATIONS, THIS SHEET PHOTOCELL: LOCATE UNDER EAVES, FACING NORTH, AVOID ANY OTHER OUTSIDE LIGHT SOURCE BRANCH CIRCUIT: CONCEALED BRANCH CIRCUIT: CONCEALED IN FLOOR SLAB BRANCH CIRCUIT: EXPOSED 'HOMERUN' TO PANEL: NUMBER OF HASH MARKS INDICATES QUANTITY OF No. 12 AWG UNGROUNDED CONDUCTORS IN 3/4" RACEWAY. GROUNDED CONDUCTORS (NEUTRALS) ARE NOT SHOWN - ONE DEDICATED NEUTRAL IS REQUIRED FOR EACH UNGROUNDED CONDUCTOR INSTALLED, SEE SPECIFICATIONS. EACH CONDUCTOR SHALL BE MIN. No. 12 AWG UNLESS NOTED OTHERWISE. WHERE COMPLETE BRANCH CIRCUIT WIRING IS NOT SHOWN, PROVIDE ACCORDING TO HOMERUNS SHOWN AND CORRESPONDING CIRCUIT NUMBERS ADJACENT TO THE DEVICE OR FIXTURE. REFER TO THE SPECIFICATIONS FOR THE WIRING METHODS. BRANCH CIRCUIT RATINGS SHALL BE BASED ON OVERCURRENT DEVICE RATINGS SHOWN IN THE PANEL SCHEDULES. REFER TO THE ELECTRICAL PANELBOARD SCHEDULES AND EQUIPMENT RATINGS & CONNECTIONS SCHEDULE FOR VOLTAGE, BRANCH CIRCUITS REQUIREMENTS, BREAKERS SIZES AND OTHER RELATED ELECTRICAL EQUIPMENT TO BE PROVIDED AND/OR INSTALLED BY THE ELECTRICAL CONTRACTOR. A AMPERES AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AH AIR HANDLER AIC AMPERAGE INTERRUPT CAPABILITY ATU AIR TERMINAL UNIT A/V AUDIO/VISUAL AWG AMERICAN WIRE GAUGE BFG BELOW FINISHED GRADE B.E. BOTTOM EDGE C. CONDUIT CU CONDENSING UNIT DAH DUCTLESS AIR HANDLER DHP DUCTLESS HEAT PUMP DACS DIGITAL ALARM COMMUNICATOR SYSTEM DIA. DIAMETER THE ELECTRICAL DRAWINGS ARE ONLY PART OF THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL REVIEW ALL OF THE DRAWINGS AND SPECIFICATIONS FOR THEIR INTERRELATIONSHIP AND REQUIRED COORDINATION BETWEEN DISCIPLINES. SYMBOL WHERE SHOWN AT OR NEAR A ROOM INDICATES THAT ROOM IS SHOWN AS A TYPICAL LARGE SCALE. (2) INDICATES THE DETAIL NUMBER AND (E4.2) INDICATES THE SHEET NUMBER. ALL CONDUCTORS SHALL BE COPPER UNLESS NOTED WITH THE WORD "ALUMINUM" IN THE DESCRIPTION. EACH DOOR SHALL HAVE ONE 3/4"C. FROM DOOR FRAME TO DOOR CONTROLLER ENCLOSURE (ASSUME WITHIN 50' OF DOOR), ONE DEDICATED 20A, 120 VOLT CIRCUIT TO SAME CONTROLLER ENCLOSURE. PRIOR TO RUNNING ANY CONDUIT, COORDINATE LOCATIONS OF ALL WALL MOUNTED DEVICES WITH WALL MOUNTED ACOUSTICAL PANELS. SEE ARCHITECTURAL DRAWINGS FOR SPACES IN WHICH WALL PANELS ARE INSTALLED. PRIOR TO RUNNING CONDUIT, COORDINATE LOCATIONS OF ALL WALL MOUNTED DEVICES WITH WALL MOUNTED SAFETY PADS IN GYMNASIUM. 1. 3. 4. 5. 6. E.C.B. ENCLOSED CIRCUIT BREAKER EF EXHAUST FAN EH ELECTRIC HEATER EMCS ENERGY MANAGEMENT CONTROL UNIT FAAP FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL G GROUND GFI GROUND-FAULT INTERRUPTING HP HORSE POWER HRVU HEAT RECOVERY VENTILATING UNIT HWCP HOT WATER CIRCULATING PUMP KCMIL KILO CIRCULAR MIL MAH MAKEUP AIR HEATER MB MAIN BREAKER MCA MINIMUM CIRCUIT AMPS MIN MINIMUM MOCP MAXIMUM OVERCURRENT PROTECTION MTD MOUNTED No. NUMBER NEC NATIONAL ELECTRIC CODE NTS NOT TO SCALE PIV POST INDICATOR VALVE RGS RIGID GALVANIZED STEEL RTU ROOFTOP UNIT SF SUPPLY FAN SPD SURGE PROTECTION DEVICE SWBD SWITCHBOARD TGB TELECOMMUNICATIONS GROUND BUS TMGB TELECOMMUNICATIONS MAIN GROUND BUS TTW THROUGH-THE-WALL HEAT PUMP TYP TYPICAL UH UNIT HEATER UNO UNLESS NOTED OTHERWISE V VOLTAGE W WATTAGE W/ WITH WH WATER HEATER WHP WALL-MOUNTED HEAT PUMP WP WEATHER PROOF XFMR TANSFORMER SMOKE DAMPER, 120V, PROVIDE POWER CONNECTION AND ALL NEEDED SMOKE DETECTION AND CONTROL MODULES AS REQUIRED BY NFPA 72 FOR PROPER OPERATION. SD FIRE ALARM REMOTE VOICE EVACUATION MICROPHONE FLUSH RECESSED WALL MOUNTED. MIC S SPEAKER - SEE DRAWINGS AND SPECIFICATIONS FOR TYPE. LA-1,3,5 'HOMERUN' TO PANEL FOR EQUIPMENT: SEE EQUIPMENT CONNECTION SCHEDULES FOR SIZE OF FEEDER AND NUMBER OF CONDUCTORS. FIRE ALARM CARBON MONOXIDE DETECTOR, PROVIDE 120 VOLT CONNECTION TO NEAREST UNSWITCHED RECEPTACLE CIRCUIT. UPPERCASE LETTER ADJACENT TO FIXTURE DENOTES DESIGNATION PER THE LIGHTING FIXTURE SCHEDULE. LOWERCASE LETTER DENOTES SWITCHLEG. THE RESPECTIVE SWITCH WILL HAVE THE SAME DESTINATIONS. NUMERAL DENOTES BRANCH CIRCUIT CONNECTION. REFER TO THE FIXTURE SCHEDULE FOR THE SPECIFIC FIXTURE INFORMATION. EMERGENCY FIXTURES SHALL HAVE FACTORY INSTALLED INTERNAL BATTERIES, PER SPECIFICATIONS. O S O S OS W HD C RECEPTACLES: NOMINAL MOUNTING HEIGHT OF RECEPTACLES SHALL BE 18" TO CENTER, UNO. IF APPLICABLE, ADJUST SO DEVICE COVER IS IN THE CENTER OF MASONRY COURSE NEAREST THAT HEIGHT. THE HEIGHT ESTABLISHED SHALL GOVERN FOR ALL BOX INSTALLATIONS, WHERE INSTALLED IN MASONRY OR FRAMED WALLS. SWITCHES: MOUNTING HEIGHT OF SWITCHES SHALL BE 46" NOMINAL, ADJUSTED IN THE SAME MANNER AS SPECIFIED ABOVE, FOR RECEPTACLES. LOWERCASE LETTER INDICATES SWITCHLEG CONNECTION. THE RESPECTIVE FIXTURE(S) WILL HAVE THE SAME DESIGNATION. 3 4 a K O RECEPTACLE: SIMPLEX RECEPTACLE: DUPLEX, TAMPER RESISTANT TYPE. RECEPTACLE: GROUND-FAULT-INTERRUPTING, TAMPER RESISTANT TYPE. IN-SLAB FLOOR BOX: SEE SPECIFICATIONS RECEPTACLE: DRYER, 30 AMP, 120/250 VOLT RECEPTACLE: SPECIAL PURPOSE , COORDINATE NEMA RATING WITH SPECIFIED EQUIPMENT ELECTRIC WATER COOLER POWER CONNECTION, GFI OUTLET HAND DRYER POWER CONNECTION: COORDINATE MOUNTING HEIGHT W/ ARCHITECTURAL ELEVATIONS SEE HAND DRYER INSTALLATION DETAIL. RECEPTACLE FOR CLOCK (RECESSED) AND CLOCK; COORDINATE MOUNTING HEIGHT & LOCATION WITH ARCHITECTURAL FLOOR PLAN AND ELEVATIONS RECEPTACLE: QUADRUPLEX, CEILING MOUNTED SWITCH: SINGLE-POLE SWITCH: THREE-WAY TYPE SWITCH: FOUR-WAY TYPE SWITCH: SUBSCRIPT THAT INDICATES CORRESPONDING FIXTURES THAT SWITCH CONTROLS SWITCH: KEY-OPERATED SWITCH: OVERRIDE OCCUPANCY SENSOR, CEILING MOUNTED OCCUPANCY SENSOR, CORNER MOUNTED OCCUPANCY SENSOR, WALL MOUNTED V S V S VS VACANCY SENSOR, CEILING MOUNTED VACANCY SENSOR, CORNER MOUNTED VACANCY SENSOR, WALL MOUNTED V SWITCH: LOW VOLTAGE OVERRIDE SWITCH FOR VACANCY SENSOR. WHERE MULTIPLE SUBSCRIPTS ARE INDICATED ("ab" FOR EXAMPLE) PROVIDE A PUSHBUTTON FOR EACH CORRESPONDING GROUP OF FIXTURES TO BE CONTROLLED (2 BUTTON SWITCH FOR "ab" FOR EXAMPLE). THE PUSHBUTTONS SHALL BE MOUNTED UNDER A SINGLE GANG FACEPLATE. D SWITCH: 0-10V DIMMER TYPE COMPATIBLE WITH DIMMING ROOM CONTROLLER. O S HB OCCUPANCY SENSOR, CEILING MOUNTED HIGHBAY TYPE LIGHTING FIXTURE: LINEAR FLUORESCENT NON- EMERGENCY EMERGENCY/ BATTERY BACKUP LIGHTING FIXTURE: LINEAR FLUORESCENT LIGHTING FIXTURE: LINEAR FLUORESCENT LIGHTING FIXTURE: FLUORESCENT STRIP LIGHTING FIXTURE: FLUORESCENT, WALL MTD. DOWNLIGHT/SCONCE FIXTURE EXIT LIGHT: UNIVERSAL MTD. DIRECTIONAL FIXTURES: EMERGENCY TYPE LIGHT TRACK: LENGTH AS SHOWN DEVICE IDENTIFIER TAGS: NUMERAL ADJACENT TO DEVICE DENOTES BRANCH CIRCUIT CONNECTION. IDENTIFIER TAGS ADJACENT TO DEVICES INDICATE: MOUNT ABOVE COUNTERTOP OR BACKSPLASH, 9" ABOVE WORK SURFACE TO CENTER MOUNT DEVICE AT HEIGHT INDICATED PROVIDE WEATHER-PROOF COVER C XX" WP REFER TO ONE-LINE DIAGRAM AND EQUIPMENT CONNECTION SCHEDULE FOR LOAD DATA USED AS THE BASIS OF DESIGN AND REQUIRED CONNECTIONS. VERIFY LOAD AND LOCATION WITH EQUIPMENT CUT-SHEETS AND INSTALLER. FIRE ALARM SIGNAL, HORN AND FLASHING LIGHT, 80" AFF TO THE BOTTOM OF THE LINES. "C" DESIGNATION INDICATES CEILING MOUNTED. 7. 8. J J MISCELLANEOUS COMPONENTS: JUNCTION BOX: MTD. ABOVE CEILING JUNCTION BOX: WALL MTD. STARTER / DISCONNECT SWITCH. SEE PLAN FOR SIZE SEE SPECIFICATIONS FOR TYPE. SCENE CONTROLLER. RECEPTACLE: QUADRUPLEX, TAMPER RESISTANT TYPE. 0-10V DIMMING SYSTEM USED IN SPACES WITH ONE DIMMED LIGHTING LOAD. SEE 0-10V DIMMING WIRING SCHEMATIC. DETAIL ON 6/E0.1. 0-10V DIMMING SYSTEM. SEE CAFETORIUMLIGHTING SCHEMATIC 0-10V DIMMING, DETAIL 5/E0.1. 0-10V DIMMING SYSTEM USED IN SPACES WITH ONE DIMMED LIGHTING LOAD. SEE 0-10V DIMMING WIRING SCHEMATIC. DETAIL 6/E0.1. D1 D2 D3 CEILING MTD. TELECOMMUNICATION JUNCTION BOX AND CONDUIT ROUGH-IN TO NEAREST ACCESSIBLE CEILING T PROFESSIONAL N E E R I G N E S I G E R E R E D No. 26308 I G R O E G A A W R. L N E R R A W WARNING: Contractors, subcontractors, vendors and suppliers are advised that the contract documents consist of Architect-reproduced printed, bound and numbered specifications, Architect-reproduced printed, bound and numbered blue- or black-line prints, addenda, post-bid addenda, and change orders only. Documents reproduced by parties other than the Architect, whether in hard copy or in electronic format, shall not be considered part of the contract documents and do not supersede the provisions of the contract documents. The contractor, subcontractors, vendors and suppliers are solely responsible for verification that information utilized in bidding, development of shop drawings, and construction of the facility are identical to the contract documents. PROJECT NUMBER PROJECT DATE APPROVED BY CHECKED BY DRAWN BY Copyright (c) 2008 All Rights Reserved. ISSUED FOR: NOT VALID UNLESS SIGNED JAMES W. BUCKLEY & ASSOCIATES INC. -- ARCHITECTS SWAINSBORO, ALBANY, ROME, SAVANNAH AND ATHENS GEORGIA SHEET NUMBER: 3/11/2016 11:22:35 AM E:\$ACTIVE JOBS\Haven Elementary\20151027ELEC-Haven-Gjc.rvt ELECTRICAL LEGEND AND SCHEDULES HAVEN ELEMENTARY 03-11-2016 11415 WAL WAL GJC FINAL SAVANNAH SAVANNAH-CHATHAM COUNTY PUBLIC SCHOOL SYSTEM GEORGIA SCHOOL CODE: 625-0131 E0.0 LIGHT FIXTURE SCHEDULE TYPE DESCRIPTION LAMPS MANUFACTURER / SERIES FINISH MOUNTING NOTES A1 2'X4' LENSED TROFFER WITH 0.125" MIN. #A12 LENS AND FLUSH STEEL DOOR WITH MITERED CORNERS. LED: 4000 LUMEN, 3500K METALUX "GRLED" SERIES, LITHONIA,LUMAX, CREE WHITE RECESSED NOTE 1, NOTE 6 A3 1'X4' LENSED TROFFER WITH 0.125" MIN. #A12 LENS, AND FLUSH STEEL DOOR WITH MITERED CORNERS. LED: 2000 LUMEN, 3500K METALUX "GRLED" SERIES, LITHONIA,LUMAX, CREE WHITE RECESSED NOTE 1, NOTE 6 A5 KITCHEN SEALED GASKETED 2'X4' LENSED TROFFER WITH 0.125" MIN. #A12 LENS AND FLUSH STEEL DOOR. PROVIDE GASKETING BETWEEN LENS AND DOOR FRAME. LED: 4000 LUMEN, 3500K METALUX "GRLED" SERIES, LITHONIA,LUMAX, CREE WHITE RECESSED NOTE 6 B1 2'X4' VOLUMETRIC TROFFER WITH LINEAR FACETED REFLECTOR AND REGRESSED REFRACTIVE SYSTEM. LED: 4000 LUMEN, 3500K METALUX "CRUZE" SERIES, LITHONIA, LUMAX, CREE WHITE RECESSED NOTE 1, NOTE 6 B2 2'X4' VOLUMETRIC TROFFER WITH LINEAR FACETED REFLECTOR AND REGRESSED REFRACTIVE SYSTEM. LED: 5000 LUMEN, 3500K METALUX "CRUZE" SERIES, LITHONIA, LUMAX, CREE WHITE RECESSED NOTE 1, NOTE 6 C LED HIGHBAY WITH WIDE DISTRIBUTION AND SEMI-DIFFUSE ACRYLIC SHIELDING AND WIREGUARD. LED: 18000 LUMEN, 3500K METALUX "HBLED" SERIES LITHONIA, LUMAX, H.E. WILLIAMS WHITE CHAIN NOTE 1, NOTE 6 D NARROW (4" MAX) EXTRUDED ALUMINUM SLOT FIXTURE, CONTINUOUS FROSTED ACRYLIC LENSE PROVIDE END PLATES AND CORNER COMPANIONS FOR COMPLETE SEAMLESS INSTALLATION FOR LENGTH INDICATED, INCLUDING CORNERS. LED: 1500 LUMENS, 4000K FOCAL POINT "SEEM 4", LEADALITE, MARK, NEORAY WHITE FLANGE - CONTINUOUS E STRIP FIXTURE, 4 FOOT LENGTH, WITH LENS. LED: 3000 LUMEN, 3500K LITHONIA "ZL" SERIES, METALUX, CREE, LUMAX, H.E. WILLIAMS WHITE SURFACE NOTE 2 F DOWNLIGH, 6" APERTURE CLEAR SPECULAR LOW IRIDECENT REFLECTOR LED: 2000 LUMEN, 3500K HALO COMMERICIAL, "PD6V132" SERIES, LITHONIA, DAYBRITE, LIGHTOLIER, PRESCOLITE WHITE TRIM RING RECESSED 0-10V DIMMING G 24" RECTANGULAR SURFACE MOUNT FIXTURE, CLEAR OPAL LENS, VANDAL RESISTANT. FIXTURE SHALL BE EQUIPPED DIMMABLE DRIVER. LED: 2600 LUMEN, 25 WATTS, 3500K LUMINAIRE "SPC 8" SERIES, LITHONIA, METALUX, COLUMBIA, H.E. WILLIAMS BLACK WALL - SURFACE H ELEVATOR PIT LIGHT, CLEAR GLASS GLOBE WITH DIE CAST ALUMINUM GUARD. 1-42 WATT TTT, 3500K RIG-A-LITE "CVPW" SERIES, STONECO "VWXL" SERIES, EXCELINE "RLW" SERIES, DAYBRITE "VFSW" SERIES, BASELITE "W2" SERIES EXPOSED PARTS CORROSION RESISTANT WALL OA WALL MOUNTED, WEDGE SHAPE EXTERIOR GRADE FIXTURE. LED: 2000 LUMEN, 3500K LITHONIA "WST" SERIES, HUBBELL, McGRAW EDISON, BETA, PHILLIPS BY ARCHITECT WALL - SURFACE PROVIDE FIXTURE WITH 90 MINUTE BATTERY. OB OPEN DOWNLIGHT, 6" APERTURE CLEAR SPECULAR LOW IRIDECENT REFLECTOR, WET LOCATION LISTED. LED: 2000 LUMEN, 3500K LITHONIA "LDN6" SERIES, HALO COMMERICIAL, DAYBRITE, LIGHTOLIER, PRESCOLITE WHITE TRIM RING RECESSED OC BUILDING MOUNTED FLOOD LIGHT WITH MOUNTING BRACKET AND ASSOCIATED HARDWARE. WIDE SYMETRIC FLOOD. LED: 14,000 LUMEN, 3500K COOPER "NIGHT FALCON" SERIES, LITHONIA "D" SERIES, BETA, PHILLIPS BY ARCHITECT WALL/VERTICAL SURFACE OD ROUND, CANOPY CEILING SURFACE MOUNTED LED LIGHT, MAX 14" DIAMETER, 4" DEEP, OPAL LENS. LED: 2385 LUMEN, 3500K LUMINAIRE LED "ARV13" SERIES, LITHONIA, HUBBELL, McGRAW EDISON, PHILLIPS BY ARCHITECT SURFACE T1 TRACK LIGHT. SEE TRACK LIGHT DETAIL SHEET E0.2. T2 7/8" METAL SNOOT, 12V, TRACK LIGHT HEAD WITH STRAIGHT TRACK. DIRECT FEED TRANSFORMER. 6 WATT DIMMABLE LED MR16 BRUCK "CLAREO SPOT" SERIES, HALO, ARCHITRAK MATT CHROME SURFACE W1 1'X4' FIXTURE, SURFACE MOUNT, LOW PROFILE, VANDLE RESISTANT. FIXTURE SHALL BE EQUIPPED WITH MOTION SENSOR. LED: 5900 LUMEN, 3500K LUMINAIRE "TSL" SERIES, LITHONIA, METALUX, COLUMBIA, H.E. WILLIAMS WHITE WALL - SURFACE XA WALL MOUNT SINGLE/DOUBLE FACE EXIT LIGHT, DIE CAST ALUMINUM, UNIVERSAL MOUNTING, GREEN LETTERS - DIRECTION OF ARROWS AS INDICATED LED LITHONIA "LE" SERIES, BEGHELLI "LC1E" SERIES, DUAL LITE "CVD" SERIES, SURE-LIGHT "CX" SERIES BRUSHED STAINLESS UNIVERSAL 90 MINUTE BATTERY XB CEILING MOUNTED SINGLE/DOUBLE FACE EXIT LIGHT, DIE CAST ALUMINUM, UNIVERSAL MOUNTING, GREEN LETTERS - DIRECTION OF ARROWS AS INDICATED LED LITHONIA "LE" SERIES, BEGHELLI "LC1E" SERIES, DUAL LITE "CVD" SERIES, SURE-LIGHT "CX" SERIES BRUSHED STAINLESS UNIVERSAL 90 MINUTE BATTERY XEM 2 HEAD, WALL MOUNT EMERGENCY BATTERY WITH FIXTURE LITHONIA "ELM" SERIES, BEGHELLI, HUBBELL, SURE-LIGHT, DUAL-LIGHT WHITE SURFACE 90 MINUTE BATTERY LIGHT FIXTURE SCHEDULE NOTES: 1 GENERAL: REFER TO LIGHTING PLANS FOR BALLAST VOLTAGES AND CONFIGURATION OF FIXTURES. FIXTURES INDICATED TO BE DIMMED SHALL BE SUPPLIED WITH DIMMING BALLAST AND ALL ASSOCIATED 0-10 VOLT WIRING. SEE DETAILS ON SHEET E0.1. 2 FIXTURES SHALL BE MOUNTED SUSPENDED OR SURFACE, GIVING RIGHT OF WAY TO HVAC DUCT WORK AND/OR EQUIPMENT. 3 PROVIDE BACKBOX ON ALL FIXTURES OF THIS TYPE SO THAT FIXTURES WITH AND WITHOUT EMERGENCY BALLAST ARE AT THE SAME DEPTH. 4 GENERAL: COORINATE ALL MOUNTING OF FIXTURES (GRID/FLANGE) WITH ARCHITECTURAL RCP. 5 FIXTURES SHALL BE SELECTED FROM THE FIXTURE SCHEDULE NOT ONLY BY CATALOG NUMBER BUT WITH CONSIDERATION TO MOUNTING, NUMBER AND TYPE OF LAMPS, AND REFERENCED NOTES. THE FIRST FIXTURE INDICATED FOR EACH TYPE WITH CATALOG NUMBER IS THE BASIS OF DESIGN FIXTURE, OTHER LISTED MANUFACTURERS PRODUCING AN EQUAL FIXTURE TO THE BASIS OF DESIGNFIXTURE MAY BE PROVIDED. 6 THIS LIGHT FIXTURE IS TO BE SUPPLIED BY THE OWNER, INSTALLED BY THE CONTRACTOR.

Upload: phamnga

Post on 06-Jul-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

FACP

FSCU

VS

WF

FAA

DH

2E4.2

F FIRE ALARM PULL STATION. WALL MOUNTED WITH OPERABLEPART OF THE DEVICE AT 46" AFF.

FIRE ALARM SIGNAL, SPEAKER AND FLASHING LIGHT, 80" AFF TOTHE BOTTOM OF THE LINES. "C" DESIGNATION INDICATESCEILING MOUNTED.

FIRE ALARM STROBE LIGHT, 80" AFF TO THE BOTTOM OF THE LENS.

FIRE ALARM CONNECTION, HOOD EXTINGUISHING SYSTEM, SEEMECHANICAL DRAWINGS FOR LOCATION. INTERLOCK WITHSHUNT TRIP BREAKERS FOR EQUIPMENT UNDER HOOD.

FIRE ALARM REMOTE LCD ANNUNCIATOR PANEL. FLUSHRECESSED WALL MOUNTED.

FIRE ALARM DOOR HOLDER, WALL MOUNTED, CONSULTARCHITECTURAL DRAWINGS TO DETERMINE TYPE REQUIRED.PROVIDE POWER FROM NEAREST RECEPTACLE CIRCUIT ANDCONNECT TO FIRE ALARM SYSTEM.

TAMPER SWITCH, FURNISHED AND INSTALLED WITH SPRINKLERSYSTEM. INTERLOCK WITH FIRE ALARM SYSTEM BY ELECTRICAL.

FLOW SWITCH, FURNISHED AND INSTALLED WITH SPRINKLERSYSTEM. INTERLOCK WITH FIRE ALARM SYSTEM BY ELECTRICAL.

FIRE ALARM SMOKE DETECTOR, CEILING MOUNTED.

FIRE ALARM DUCT SMOKE DETECTOR LOCATED IN HVAC DUCT.

FIRE ALARM CONTROL PANEL, SURFACE WALL MOUNTED.

FIRE ALARM SIGNAL, HORN. 90" AFF TO THE TOP OF THE DEVICE.WEATHER PROOF.

FIRE ALARM HEAT DETECTOR, 135 DEG, OPERATION.

FIRE ALARM STROBE LIGHT, CEILING MOUNTED.

S

M

FIRE ALARM:

H

S WP

IC

AD

AC

S

2.

COORDINATE MOUNTING HEIGHTS, DEVICE LOCATIONS & POWER/CONTROL REQUIREMENTSWITH ARCHITECTURAL DRAWINGS AND SYSTEM INSTALLER.

INTRUSION DETECTION SYSTEM:

CONDUIT SLEEVE: NUMBER & SIZE, (2)-2" FOR ALL CLASSROOMS,(1)-2" FOR ALL OFFICES, UNO

CABLE TRAY: SIZE AS INDICATED, 18"W x 4"H TYP.

INTERCOM SPEAKER: WEATHERPROOF WALL MOUNTED AT 96"AFF.

MICROPHONE JACK: WALL MOUNTED AT 18" AFF, UNO.

PUSH BUTTON EMERGENCY CALL STATION: 46" AFF, UNO.

ADMINISTRATIVE DISPLAY PHONE: WALL MOUNT AT 46" AFF

INTRUSION SYSTEM: KEY-PAD, MOUNT 48"AFF

INTRUSION DETECTION DEVICE: WALL MTD.

ACCESS CONTROL SYSTEMS

SEE DETAIL 2/T3.0 FOR POWER, POWER DISCONNECT, LOWVOLTAGE CABLING, BOXES AND CONDUIT REQUIREMENTS.REFER TO ARCHITECTURAL PLANS AND DOOR SPECIFICATIONSFOR ADDITIONAL REQUIREMENTS.

INTERCOM SPEAKER: 2' X 2' SQUARE CEILING MOUNTED

COORDINATE MOUNTING HEIGHTS, DEVICE LOCATIONS & POWER/CONTROL REQUIREMENTSWITH ARCHITECTURAL DRAWINGS AND SYSTEM INSTALLER.

SPEAKER SYSTEM:

CABLING COMPONENTS:

THE CONTRACTOR SHALL PROVIDE ROUGH-IN FOR ALL DEVICES AND WIRING.ROUGH-IN REQUIREMENTS ARE SPECIFIED IN SECTION 261010. VERIFY ADJACENCYTO CORRESPONDING POWER RECEPTACLES. OTHER DEVICES WHOSE LOCATIONSARE NOT DEPENDENT ON RECEPTACLE PLACEMENT SHALL BE COORDINATED WITHSYSTEM INSTALLER.

WALL MTD. TELECOMMUNICATION JUNCTION BOX ANDCONDUIT ROUGH-IN TO NEAREST ACCESSIBLE CEILING

CEILING MTD. TELECOMMUNICATION JUNCTION BOX

WALL MTD. TELECOMMUNICATION JUNCTION BOX ANDCONDUIT ROUGH-IN TO NEAREST ACCESSIBLE CEILING

CEILING MTD. TELECOMMUNICATION JUNCTION BOX ANDCONDUIT ROUGH-IN TO NEAREST ACCESSIBLE CEILING

WALL MTD. TELECOMMUNICATION JUNCTION BOX ANDCONDUIT ROUGH-IN TO NEAREST ACCESSIBLE CEILING

ROUGH-IN FOR LOW VOLTAGE SYSTEMS:

KP

PC

XX-1

T

M

ABBREVIATIONS:

LEGEND:

LIGHTING FIXTURES: ELECTRICAL EQUIPMENT:

GENERAL NOTES:

BRANCH CIRCUITS:

CONDUCTOR COUNTS ARE SHOWN ON THE HOMERUNS ONLY. CONTRACTOR SHALLDETERMINE COUNTS FOR INTERMEDIATE RUNS BASED ON THE MANNER IN WHICH THECIRCUIT ELEMENTS ARE CONNECTED. REFER TO THE SPECIFICATION SECTIONS 262010,262080, & 26030 FOR SPECIAL REQUIREMENTS.

LA-1,3,5

SWITCH: MOTOR RATED, WITHOUT OVERLOAD PROTECTION

DISCONNECT SWITCH

DRY-TYPE TRANSFORMER

PANELBOARD: SURFACE MOUNTED

EQUIPMENT AS NOTED, SEE ABBREVIATIONS, THIS SHEET

PHOTOCELL: LOCATE UNDER EAVES, FACING NORTH,AVOID ANY OTHER OUTSIDE LIGHT SOURCE

BRANCH CIRCUIT: CONCEALED

BRANCH CIRCUIT: CONCEALED IN FLOOR SLAB

BRANCH CIRCUIT: EXPOSED

'HOMERUN' TO PANEL: NUMBER OF HASH MARKS INDICATESQUANTITY OF No. 12 AWG UNGROUNDED CONDUCTORS IN 3/4"RACEWAY. GROUNDED CONDUCTORS (NEUTRALS) ARE NOTSHOWN - ONE DEDICATED NEUTRAL IS REQUIRED FOR EACHUNGROUNDED CONDUCTOR INSTALLED, SEE SPECIFICATIONS.EACH CONDUCTOR SHALL BE MIN. No. 12 AWG UNLESS NOTEDOTHERWISE.

WHERE COMPLETE BRANCH CIRCUIT WIRING IS NOT SHOWN, PROVIDEACCORDING TO HOMERUNS SHOWN AND CORRESPONDING CIRCUIT NUMBERSADJACENT TO THE DEVICE OR FIXTURE. REFER TO THE SPECIFICATIONS FORTHE WIRING METHODS. BRANCH CIRCUIT RATINGS SHALL BE BASED ONOVERCURRENT DEVICE RATINGS SHOWN IN THE PANEL SCHEDULES.

REFER TO THE ELECTRICAL PANELBOARD SCHEDULES AND EQUIPMENTRATINGS & CONNECTIONS SCHEDULE FOR VOLTAGE, BRANCH CIRCUITSREQUIREMENTS, BREAKERS SIZES AND OTHER RELATED ELECTRICALEQUIPMENT TO BE PROVIDED AND/OR INSTALLED BY THE ELECTRICALCONTRACTOR.

A AMPERES

AFFABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AH AIR HANDLER

AIC AMPERAGE INTERRUPT CAPABILITY

ATU AIR TERMINAL UNIT

A/V AUDIO/VISUAL

AWG AMERICAN WIRE GAUGE

BFG BELOW FINISHED GRADE

B.E. BOTTOM EDGE

C. CONDUIT

CU CONDENSING UNIT

DAH DUCTLESS AIR HANDLER

DHP DUCTLESS HEAT PUMP

DACS DIGITAL ALARM COMMUNICATOR SYSTEM

DIA. DIAMETER

THE ELECTRICAL DRAWINGS ARE ONLY PART OF THE CONTRACT DOCUMENTS.THE CONTRACTOR SHALL REVIEW ALL OF THE DRAWINGS AND SPECIFICATIONSFOR THEIR INTERRELATIONSHIP AND REQUIRED COORDINATION BETWEENDISCIPLINES.

SYMBOL WHERE SHOWN AT OR NEAR A ROOM INDICATES THATROOM IS SHOWN AS A TYPICAL LARGE SCALE. (2) INDICATESTHE DETAIL NUMBER AND (E4.2) INDICATES THE SHEET NUMBER.

ALL CONDUCTORS SHALL BE COPPER UNLESS NOTED WITH THE WORD"ALUMINUM" IN THE DESCRIPTION.

EACH DOOR SHALL HAVE ONE 3/4"C. FROM DOOR FRAME TO DOORCONTROLLER ENCLOSURE (ASSUME WITHIN 50' OF DOOR), ONE DEDICATED20A, 120 VOLT CIRCUIT TO SAME CONTROLLER ENCLOSURE.

PRIOR TO RUNNING ANY CONDUIT, COORDINATE LOCATIONS OF ALL WALLMOUNTED DEVICES WITH WALL MOUNTED ACOUSTICAL PANELS. SEEARCHITECTURAL DRAWINGS FOR SPACES IN WHICH WALL PANELS AREINSTALLED.

PRIOR TO RUNNING CONDUIT, COORDINATE LOCATIONS OF ALL WALLMOUNTED DEVICES WITH WALL MOUNTED SAFETY PADS IN GYMNASIUM.

1.

3.

4.

5.

6.

E.C.B. ENCLOSED CIRCUIT BREAKER

EF EXHAUST FAN

EH ELECTRIC HEATER

EMCS ENERGY MANAGEMENT CONTROL UNIT

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

G GROUND

GFI GROUND-FAULT INTERRUPTING

HP HORSE POWER

HRVU HEAT RECOVERY VENTILATING UNIT

HWCP HOT WATER CIRCULATING PUMP

KCMIL KILO CIRCULAR MIL

MAH MAKEUP AIR HEATER

MB MAIN BREAKER

MCA MINIMUM CIRCUIT AMPS

MIN MINIMUM

MOCP MAXIMUM OVERCURRENT PROTECTION

MTD MOUNTED

No. NUMBER

NEC NATIONAL ELECTRIC CODE

NTS NOT TO SCALE

PIV POST INDICATOR VALVE

RGS RIGID GALVANIZED STEEL

RTU ROOFTOP UNIT

SF SUPPLY FAN

SPD SURGE PROTECTION DEVICE

SWBD SWITCHBOARD

TGB TELECOMMUNICATIONS GROUND BUS

TMGB TELECOMMUNICATIONS MAIN GROUND BUS

TTW THROUGH-THE-WALL HEAT PUMP

TYP TYPICAL

UH UNIT HEATER

UNO UNLESS NOTED OTHERWISE

V VOLTAGE

W WATTAGE

W/ WITH

WH WATER HEATER

WHP WALL-MOUNTED HEAT PUMP

WP WEATHER PROOF

XFMR TANSFORMER

SMOKE DAMPER, 120V, PROVIDE POWER CONNECTION AND ALLNEEDED SMOKE DETECTION AND CONTROL MODULES ASREQUIRED BY NFPA 72 FOR PROPER OPERATION.

SD

FIRE ALARM REMOTE VOICE EVACUATION MICROPHONE FLUSHRECESSED WALL MOUNTED.

MIC

S SPEAKER - SEE DRAWINGS AND SPECIFICATIONS FOR TYPE.

LA-1,3,5

'HOMERUN' TO PANEL FOR EQUIPMENT: SEE EQUIPMENTCONNECTION SCHEDULES FOR SIZE OF FEEDER AND NUMBEROF CONDUCTORS.

FIRE ALARM CARBON MONOXIDE DETECTOR, PROVIDE 120 VOLTCONNECTION TO NEAREST UNSWITCHED RECEPTACLE CIRCUIT.

UPPERCASE LETTER ADJACENT TO FIXTURE DENOTES DESIGNATION PER THELIGHTING FIXTURE SCHEDULE. LOWERCASE LETTER DENOTES SWITCHLEG. THERESPECTIVE SWITCH WILL HAVE THE SAME DESTINATIONS. NUMERAL DENOTESBRANCH CIRCUIT CONNECTION.

REFER TO THE FIXTURE SCHEDULE FOR THE SPECIFIC FIXTURE INFORMATION.

EMERGENCY FIXTURES SHALL HAVE FACTORY INSTALLED INTERNAL BATTERIES,PER SPECIFICATIONS.

OS

OS

OS

W

HD

C

RECEPTACLES:

NOMINAL MOUNTING HEIGHT OF RECEPTACLES SHALL BE 18" TO CENTER, UNO. IFAPPLICABLE, ADJUST SO DEVICE COVER IS IN THE CENTER OF MASONRY COURSENEAREST THAT HEIGHT. THE HEIGHT ESTABLISHED SHALL GOVERN FOR ALL BOXINSTALLATIONS, WHERE INSTALLED IN MASONRY OR FRAMED WALLS.

SWITCHES:

MOUNTING HEIGHT OF SWITCHES SHALL BE 46" NOMINAL, ADJUSTED IN THE SAMEMANNER AS SPECIFIED ABOVE, FOR RECEPTACLES. LOWERCASE LETTERINDICATES SWITCHLEG CONNECTION. THE RESPECTIVE FIXTURE(S) WILL HAVE THESAME DESIGNATION.

3

4

a

K

O

RECEPTACLE: SIMPLEX

RECEPTACLE: DUPLEX, TAMPER RESISTANT TYPE.

RECEPTACLE: GROUND-FAULT-INTERRUPTING, TAMPERRESISTANT TYPE.

IN-SLAB FLOOR BOX: SEE SPECIFICATIONS

RECEPTACLE: DRYER, 30 AMP, 120/250 VOLT

RECEPTACLE: SPECIAL PURPOSE , COORDINATE NEMARATING WITH SPECIFIED EQUIPMENT

ELECTRIC WATER COOLER POWER CONNECTION, GFI OUTLET

HAND DRYER POWER CONNECTION: COORDINATE MOUNTINGHEIGHT W/ ARCHITECTURAL ELEVATIONS SEE HAND DRYERINSTALLATION DETAIL.

RECEPTACLE FOR CLOCK (RECESSED) AND CLOCK;COORDINATE MOUNTING HEIGHT & LOCATION WITHARCHITECTURAL FLOOR PLAN AND ELEVATIONS

RECEPTACLE: QUADRUPLEX, CEILING MOUNTED

SWITCH: SINGLE-POLE

SWITCH: THREE-WAY TYPE

SWITCH: FOUR-WAY TYPE

SWITCH: SUBSCRIPT THAT INDICATES CORRESPONDINGFIXTURES THAT SWITCH CONTROLS

SWITCH: KEY-OPERATED

SWITCH: OVERRIDE

OCCUPANCY SENSOR, CEILING MOUNTED

OCCUPANCY SENSOR, CORNER MOUNTED

OCCUPANCY SENSOR, WALL MOUNTED

VS

VS

VS

VACANCY SENSOR, CEILING MOUNTED

VACANCY SENSOR, CORNER MOUNTED

VACANCY SENSOR, WALL MOUNTED

VSWITCH: LOW VOLTAGE OVERRIDE SWITCH FOR VACANCYSENSOR. WHERE MULTIPLE SUBSCRIPTS ARE INDICATED("ab" FOR EXAMPLE) PROVIDE A PUSHBUTTON FOR EACHCORRESPONDING GROUP OF FIXTURES TO BE CONTROLLED(2 BUTTON SWITCH FOR "ab" FOR EXAMPLE). THEPUSHBUTTONS SHALL BE MOUNTED UNDER A SINGLE GANGFACEPLATE.

D SWITCH: 0-10V DIMMER TYPE COMPATIBLE WITH DIMMINGROOM CONTROLLER.

OSHB

OCCUPANCY SENSOR, CEILING MOUNTED HIGHBAY TYPE

LIGHTING FIXTURE: LINEAR FLUORESCENT

NON-EMERGENCY

EMERGENCY/BATTERY BACKUP

LIGHTING FIXTURE: LINEAR FLUORESCENT

LIGHTING FIXTURE: LINEAR FLUORESCENT

LIGHTING FIXTURE: FLUORESCENT STRIP

LIGHTING FIXTURE: FLUORESCENT, WALL MTD.

DOWNLIGHT/SCONCE FIXTURE

EXIT LIGHT: UNIVERSAL MTD.

DIRECTIONAL FIXTURES: EMERGENCY TYPE

LIGHT TRACK: LENGTH AS SHOWN

DEVICE IDENTIFIER TAGS:

NUMERAL ADJACENT TO DEVICE DENOTES BRANCH CIRCUIT CONNECTION.IDENTIFIER TAGS ADJACENT TO DEVICES INDICATE:

MOUNT ABOVE COUNTERTOP OR BACKSPLASH, 9" ABOVEWORK SURFACE TO CENTER

MOUNT DEVICE AT HEIGHT INDICATED

PROVIDE WEATHER-PROOF COVER

C

XX"

WP

REFER TO ONE-LINE DIAGRAM AND EQUIPMENT CONNECTION SCHEDULE FORLOAD DATA USED AS THE BASIS OF DESIGN AND REQUIRED CONNECTIONS.VERIFY LOAD AND LOCATION WITH EQUIPMENT CUT-SHEETS AND INSTALLER.

FIRE ALARM SIGNAL, HORN AND FLASHING LIGHT, 80" AFF TO THEBOTTOM OF THE LINES. "C" DESIGNATION INDICATES CEILINGMOUNTED.

7.

8.

J

J

MISCELLANEOUS COMPONENTS:

JUNCTION BOX: MTD. ABOVE CEILING

JUNCTION BOX: WALL MTD.

STARTER / DISCONNECT SWITCH. SEE PLAN FOR SIZESEE SPECIFICATIONS FOR TYPE.

SCENE CONTROLLER.

RECEPTACLE: QUADRUPLEX, TAMPER RESISTANT TYPE.

0-10V DIMMING SYSTEM USED IN SPACES WITH ONEDIMMED LIGHTING LOAD. SEE 0-10V DIMMING WIRINGSCHEMATIC. DETAIL ON 6/E0.1.

0-10V DIMMING SYSTEM. SEE CAFETORIUMLIGHTING SCHEMATIC0-10V DIMMING, DETAIL 5/E0.1.

0-10V DIMMING SYSTEM USED IN SPACES WITH ONEDIMMED LIGHTING LOAD. SEE 0-10V DIMMING WIRINGSCHEMATIC. DETAIL 6/E0.1.

D1

D2

D3

CEILING MTD. TELECOMMUNICATION JUNCTION BOX ANDCONDUIT ROUGH-IN TO NEAREST ACCESSIBLE CEILING

T

PROFESSIONAL

NE ER

IGNE

SIGER

ERED

No. 26308

IGROEG

A

A

W

R.L

NERRA

W

WA

RN

ING

: C

ontra

ctor

s, s

ubco

ntra

ctor

s, v

endo

rs a

nd s

uppl

iers

are

adv

ised

that

the

cont

ract

doc

umen

ts c

onsi

st o

fA

rchi

tect

-rep

rodu

ced

prin

ted,

bou

nd a

nd n

umbe

red

spec

ifica

tions

, Arc

hite

ct-r

epro

duce

d pr

inte

d, b

ound

and

num

bere

dbl

ue- o

r bla

ck-li

ne p

rints

, add

enda

, pos

t-bid

add

enda

, and

cha

nge

orde

rs o

nly.

Doc

umen

ts re

prod

uced

by

parti

es o

ther

than

the

Arc

hite

ct, w

heth

er in

har

d co

py o

r in

elec

troni

c fo

rmat

, sha

ll no

t be

cons

ider

ed p

art o

f the

con

tract

doc

umen

ts a

nddo

not

sup

erse

de th

e pr

ovis

ions

of t

he c

ontra

ct d

ocum

ents

. T

he c

ontra

ctor

, sub

cont

ract

ors,

ven

dors

and

sup

plie

rs a

reso

lely

resp

onsi

ble

for v

erifi

catio

n th

at in

form

atio

n ut

ilize

d in

bid

ding

, dev

elop

men

t of s

hop

draw

ings

, and

con

stru

ctio

n of

the

faci

lity

are

iden

tical

to th

e co

ntra

ct d

ocum

ents

.

PROJECT NUMBER

PROJECT DATE

APPROVED BY

CHECKED BY

DRAWN BY

Copyright (c) 2008All Rights Reserved.

ISSUED FOR:

NOT VALID UNLESS SIGNED

JAM

ES

W.

BU

CK

LE

Y &

AS

SO

CIA

TE

S I

NC

. --

AR

CH

ITE

CT

SS

WA

INS

BO

RO

, A

LB

AN

Y,

RO

ME

, S

AV

AN

NA

H A

ND

AT

HE

NS

GE

OR

GIA

SHEET

NUMBER:

3/11

/201

6 11

:22:

35 A

ME

:\$A

CTI

VE

JO

BS

\Hav

en E

lem

enta

ry\2

0151

027E

LEC

-Hav

en-G

jc.rv

t

ELE

CT

RIC

AL L

EG

EN

D A

ND

SC

HE

DU

LE

S

HA

VE

N E

LE

ME

NT

AR

Y

03-11-2016

11415

WAL

WAL

GJC

FINAL

SA

VA

NN

AH

S

AV

AN

NA

H-C

HA

TH

AM

CO

UN

TY

PU

BLIC

SC

HO

OL S

YS

TE

M G

EO

RG

IAS

CH

OO

L C

OD

E: 625-0

131

E0.0

LIGHT FIXTURE SCHEDULE

TYPE DESCRIPTION LAMPS

MANUFACTURER /

SERIES FINISH MOUNTING NOTES

A1 2'X4' LENSED TROFFER WITH 0.125" MIN. #A12LENS AND FLUSH STEEL DOOR WITH MITEREDCORNERS.

LED: 4000 LUMEN,3500K

METALUX "GRLED" SERIES,LITHONIA,LUMAX, CREE

WHITE RECESSED NOTE 1, NOTE 6

A3 1'X4' LENSED TROFFER WITH 0.125" MIN. #A12LENS, AND FLUSH STEEL DOOR WITH MITEREDCORNERS.

LED: 2000 LUMEN,3500K

METALUX "GRLED" SERIES,LITHONIA,LUMAX, CREE

WHITE RECESSED NOTE 1, NOTE 6

A5 KITCHEN SEALED GASKETED 2'X4' LENSEDTROFFER WITH 0.125" MIN. #A12 LENS ANDFLUSH STEEL DOOR. PROVIDE GASKETINGBETWEEN LENS AND DOOR FRAME.

LED: 4000 LUMEN,3500K

METALUX "GRLED" SERIES,LITHONIA,LUMAX, CREE

WHITE RECESSED NOTE 6

B1 2'X4' VOLUMETRIC TROFFER WITH LINEARFACETED REFLECTOR AND REGRESSEDREFRACTIVE SYSTEM.

LED: 4000 LUMEN,3500K

METALUX "CRUZE" SERIES,LITHONIA, LUMAX, CREE

WHITE RECESSED NOTE 1, NOTE 6

B2 2'X4' VOLUMETRIC TROFFER WITH LINEARFACETED REFLECTOR AND REGRESSEDREFRACTIVE SYSTEM.

LED: 5000 LUMEN,3500K

METALUX "CRUZE" SERIES,LITHONIA, LUMAX, CREE

WHITE RECESSED NOTE 1, NOTE 6

C LED HIGHBAY WITH WIDE DISTRIBUTION ANDSEMI-DIFFUSE ACRYLIC SHIELDING ANDWIREGUARD.

LED: 18000LUMEN, 3500K

METALUX "HBLED" SERIESLITHONIA, LUMAX, H.E.WILLIAMS

WHITE CHAIN NOTE 1, NOTE 6

D NARROW (4" MAX) EXTRUDED ALUMINUM SLOTFIXTURE, CONTINUOUS FROSTED ACRYLICLENSE PROVIDE END PLATES AND CORNERCOMPANIONS FOR COMPLETE SEAMLESSINSTALLATION FOR LENGTH INDICATED,INCLUDING CORNERS.

LED: 1500LUMENS, 4000K

FOCAL POINT "SEEM 4",LEADALITE, MARK, NEORAY

WHITE FLANGE -CONTINUOUS

E STRIP FIXTURE, 4 FOOT LENGTH, WITH LENS. LED: 3000 LUMEN,3500K

LITHONIA "ZL" SERIES,METALUX, CREE, LUMAX,H.E. WILLIAMS

WHITE SURFACE NOTE 2

F DOWNLIGH, 6" APERTURE CLEAR SPECULARLOW IRIDECENT REFLECTOR

LED: 2000 LUMEN,3500K

HALO COMMERICIAL,"PD6V132" SERIES,LITHONIA, DAYBRITE,LIGHTOLIER, PRESCOLITE

WHITE TRIMRING

RECESSED 0-10V DIMMING

G 24" RECTANGULAR SURFACE MOUNT FIXTURE,CLEAR OPAL LENS, VANDAL RESISTANT.FIXTURE SHALL BE EQUIPPED DIMMABLEDRIVER.

LED: 2600 LUMEN,25 WATTS, 3500K

LUMINAIRE "SPC 8" SERIES,LITHONIA, METALUX,COLUMBIA, H.E. WILLIAMS

BLACK WALL - SURFACE

H ELEVATOR PIT LIGHT, CLEAR GLASS GLOBEWITH DIE CAST ALUMINUM GUARD.

1-42 WATT TTT,3500K

RIG-A-LITE "CVPW" SERIES,STONECO "VWXL" SERIES,EXCELINE "RLW" SERIES,DAYBRITE "VFSW" SERIES,BASELITE "W2" SERIES

EXPOSEDPARTS

CORROSIONRESISTANT

WALL

OA WALL MOUNTED, WEDGE SHAPE EXTERIORGRADE FIXTURE.

LED: 2000 LUMEN,3500K

LITHONIA "WST" SERIES,HUBBELL, McGRAW EDISON,BETA, PHILLIPS

BYARCHITECT

WALL - SURFACE PROVIDEFIXTURE WITH90 MINUTEBATTERY.

OB OPEN DOWNLIGHT, 6" APERTURE CLEARSPECULAR LOW IRIDECENT REFLECTOR, WETLOCATION LISTED.

LED: 2000 LUMEN,3500K

LITHONIA "LDN6" SERIES,HALO COMMERICIAL,DAYBRITE, LIGHTOLIER,PRESCOLITE

WHITE TRIMRING

RECESSED

OC BUILDING MOUNTED FLOOD LIGHT WITHMOUNTING BRACKET AND ASSOCIATEDHARDWARE. WIDE SYMETRIC FLOOD.

LED: 14,000LUMEN, 3500K

COOPER "NIGHT FALCON"SERIES, LITHONIA "D"SERIES, BETA, PHILLIPS

BYARCHITECT

WALL/VERTICALSURFACE

OD ROUND, CANOPY CEILING SURFACE MOUNTEDLED LIGHT, MAX 14" DIAMETER, 4" DEEP, OPALLENS.

LED: 2385 LUMEN,3500K

LUMINAIRE LED "ARV13"SERIES, LITHONIA, HUBBELL,McGRAW EDISON, PHILLIPS

BYARCHITECT

SURFACE

T1 TRACK LIGHT. SEE TRACK LIGHT DETAIL SHEETE0.2.

T2 7/8" METAL SNOOT, 12V, TRACK LIGHT HEADWITH STRAIGHT TRACK. DIRECT FEEDTRANSFORMER.

6 WATTDIMMABLE LED

MR16

BRUCK "CLAREO SPOT"SERIES, HALO, ARCHITRAK

MATTCHROME

SURFACE

W1 1'X4' FIXTURE, SURFACE MOUNT, LOW PROFILE,VANDLE RESISTANT. FIXTURE SHALL BEEQUIPPED WITH MOTION SENSOR.

LED: 5900 LUMEN,3500K

LUMINAIRE "TSL" SERIES,LITHONIA, METALUX,COLUMBIA, H.E. WILLIAMS

WHITE WALL - SURFACE

XA WALL MOUNT SINGLE/DOUBLE FACE EXITLIGHT, DIE CAST ALUMINUM, UNIVERSALMOUNTING, GREEN LETTERS - DIRECTION OFARROWS AS INDICATED

LED LITHONIA "LE" SERIES,BEGHELLI "LC1E" SERIES,DUAL LITE "CVD" SERIES,SURE-LIGHT "CX" SERIES

BRUSHEDSTAINLESS

UNIVERSAL 90 MINUTEBATTERY

XB CEILING MOUNTED SINGLE/DOUBLE FACE EXITLIGHT, DIE CAST ALUMINUM, UNIVERSALMOUNTING, GREEN LETTERS - DIRECTION OFARROWS AS INDICATED

LED LITHONIA "LE" SERIES,BEGHELLI "LC1E" SERIES,DUAL LITE "CVD" SERIES,SURE-LIGHT "CX" SERIES

BRUSHEDSTAINLESS

UNIVERSAL 90 MINUTEBATTERY

XEM 2 HEAD, WALL MOUNT EMERGENCY BATTERY WITH FIXTURE LITHONIA "ELM" SERIES,BEGHELLI, HUBBELL,SURE-LIGHT, DUAL-LIGHT

WHITE SURFACE 90 MINUTEBATTERY

LIGHT FIXTURE SCHEDULE NOTES:

1 GENERAL: REFER TO LIGHTING PLANS FOR BALLAST VOLTAGES ANDCONFIGURATION OF FIXTURES. FIXTURES INDICATED TO BE DIMMED SHALL BESUPPLIED WITH DIMMING BALLAST AND ALL ASSOCIATED 0-10 VOLT WIRING.SEE DETAILS ON SHEET E0.1.

2 FIXTURES SHALL BE MOUNTED SUSPENDED OR SURFACE, GIVING RIGHT OFWAY TO HVAC DUCT WORK AND/OR EQUIPMENT.

3 PROVIDE BACKBOX ON ALL FIXTURES OF THIS TYPE SO THAT FIXTURES WITHAND WITHOUT EMERGENCY BALLAST ARE AT THE SAME DEPTH.

4 GENERAL: COORINATE ALL MOUNTING OF FIXTURES (GRID/FLANGE) WITHARCHITECTURAL RCP.

5 FIXTURES SHALL BE SELECTED FROM THE FIXTURE SCHEDULE NOT ONLY BYCATALOG NUMBER BUT WITH CONSIDERATION TO MOUNTING, NUMBER ANDTYPE OF LAMPS, AND REFERENCED NOTES. THE FIRST FIXTURE INDICATEDFOR EACH TYPE WITH CATALOG NUMBER IS THE BASIS OF DESIGN FIXTURE,OTHER LISTED MANUFACTURERS PRODUCING AN EQUAL FIXTURE TO THEBASIS OF DESIGNFIXTURE MAY BE PROVIDED.

6 THIS LIGHT FIXTURE IS TO BE SUPPLIED BY THE OWNER, INSTALLED BY THECONTRACTOR.

.

.

.

W D

DN

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD FD

FDFD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FDFD

FD

FD

FDFD

FDFD

FD

FD

FD

FD

FD

FD

FDFD

FDFD

FD

FD

FD

FD

AC

AC

AC

AC

AC

ACAC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

KP

KP

PS

PS

KP

KP

KP

AC

ACACAC AC

AC

AC

AC

AC

AC

FINISHED CEILING3#12,1/2IN. FLEX

3#12, 1 / 2 IN. C

INTERIOR VIEW

1 IN. C.

1 IN. C.

MAKE ALL CONNECTIONS AND PROVIDE ALL ITEMS REQUIRED FORCOMPLETE OPERATING SYSTEM AS REQUIRED BY MANUFACTURER

ELECTRICDOORSTRIKE

INTERIOR VIEW

ELECTRICDOORSTRIKE

PUSH TOEXITBUTTONS

REQUESTTO EXITDETECTOR

REQUESTTO EXITDETECTOR

DOORS WITH ELECTRIC DOOR STRIKE

POWER SUPPLYAND CONTROLLER

(TYPICAL)

LOCATE AT RECEPTIONDESK COORDINATEEXACT LOCATION WITHARCHITECT

MOTOR RATEDSWITCH

1ST GRADE

1602

OFFICE

1204.1

KINDERGARTEN

1605

1ST GRADE

1601

2ND GRADE

1506

2ND GRADE

1507

1ST GRADE

1503

ART

1303

VEST

1303.1

CLOSET

1104.1

ELEC.

1113

VAULT

1111.1

RESTING

1109.1

T.

1104.3

2ND GRADE

1510

WOMEN

1502.1

MEN

1502.2

ELEC.

1600.6

JAN.

1600.2

KINDERGARTEN

1608

INFO SPEC

1107

VEST.

1104.2PRINCIPAL

1104

BOOK STOR.

1500.3

VEST

1502

TEACHER RESOURCE

1502.3

T.

1109.2

BOOK KEEPER

1105

CLINIC

1109

1ST GRADE

1501

EIP

1504

2ND GRADE

1505

2ND GRADE

1508

T.

1508.2

VEST.

1508.1

MECH

1500.4

T.

1508.3

T.

1504.2

VEST

1504.1

MECH

1500.2

T.

1504.3

MECH

1500.7

T.

1505.3

T.

1505.2

VEST.

1505.1

MECH

1500.5

T.

1501.3

T.

1501.2

VEST

1501.1

KINDERGARTEN

1606

1ST GRADE

1604

KINDERGARTEN

1603

KINDERGARTEN

1607

T.

1602.2

VEST.

1602.1

MECH

1600.8

T.

1602.3

T.

1606.2

VEST.

1606.1

MECH

1600.10

T.

1606.3

MECH

1600.1

T.

1601.3

T.

1601.2

VEST.

1601.1

MECH

1600.3

T.

1607.3

T.

1607.2

VEST.

1607.1

MECH.

1212

SPRINKLER/RISER

1211

ELEC

1213

GENERAL OFFICE

1101

DRY FOOD STORAGE

1205

MECH.

1117

ENTRY

1000

HALLWAY

1103.1

STUDENT RECEPTION

1103

WORKROOM

1111

COUNSELOR

1108

CONFERENCE

1203

LOCKERS

1208

TESTING

1110

SIS

1106

FREEZER

1209

COOLER

1207

SERVING

1202

KITCHEN

1204

ELEC

1400.2

PRE-K

1401

DATA

1400.4

CLO.

1404.1

MEN

1408

HALL

1200.1

CORRIDOR

1300

GIRLS

1306

CORRIDOR

1500CORRIDOR

1600

T.

1600.7

STORAGE

1500.11DATA

1500.1

ASSUMED PRIMARY STAFF ENTRYVERIFY WITH ARCHITECTPRIOR TO ROUGH IN

PROVIDE HINGEDTHERMOPLASTIC SHIELDCOMPATIBLE WITH KEYPADSTI-7511F OR EQUAL

E1.5

3J

MONUMENTAL STAIR

1001.3

MEN

1115.1

WOMEN

1115.2

VEST.

1115

STOR.

1301.1

STORAGE

1303.3

MECH

1300.1T.

1301.2

T.

1303.2

STAIR

2000.3

ENTRY

1001.2

JAN.

1300.6

VEST.

1401.1

T.

1401.2

STOR.

1409

STOR.

1407

PARENT RESOURCES

1302

T.

1208.1

T.

1100.1

JAN

1200.3

MECH

1400.1

T.

1403.2

GYM STOR.

1402.1

T.

1404.2

JAN.

1206.1

CAN WASH

1210

WOMEN

1410

VEST

1406

CORRIDOR

1001

STAGE

1201

CORRIDOR

1400

PRE-K

1403

BOYS

1304MUSIC

1301

CONF.

1102

VISITOR RECEPTION

1100

HALL

1206

OFFICE

1404

STORAGE

1200.4

ELEV.

1001.1

ATHLETICS

1402

STAIR

1500.9

STAIRS

1600.5

CAFETERIA

1200

@20' AFF@20' AFF

CRDPS

CR

DPSDPSDPS

CR CR

DPS

DPS

CR

CR

CR

DPS

DPS

DPS

DPS

CR

DPS

CR

DPS

DPS

DPS

CR

CR

B

B

CR

4

TO NEAREST 120 VOLT, 20 AMPUNSWITCHED RECEPTACLECIRCUIT

MOTOR RATEDSWITCH

3#12, 1 / 2 IN. C

INTERIOR VIEW

1 1

22

3

1/2" C. 1/2" C.

5 5

THIS DRAWING IS INTENDED TO INDICATE CONDUIT INFRASTRUCTUREREQUIREMENT ONLY. COORDINATE EXACT REQUIRED COMPONENTSWITH ARCHITECTURAL DOOR SPECIFICATIONS. PROVIDE ALL CONDUITAND BOXES FOR COMPLETE ACCESS CONTROL INSTALLATION.

3#12, 1/2"C.(FLEXIBLECONDUIT)

NOTES:1

2

4

(ACCESS CONTROL CONNECTIONS)

DOOR POSITION SWITCH.

CURRENT TRANSFER HINGE

POWER SUPPLY.

CARD READER.

DELAYED EGRESS SYSTEM - NORMALLY CLOSED FIRE ALARMRELAY REQUIRED, PLUGNPLAY. NORMALLY CLOSED FIRE ALARMRELAY REQUIRED FOR THE DELAYED EGRESS APPLICATION.

3

5

TO MDF/IDF

PROVIDE 12 CONDUCTOR20 GAUGE WIRE WITH THEFOLLOWING COLORS: BLACK,RED, WHITE, GREEN, ORANGE,BLUE, BROWN, YELLOW, PINK,GRAY, TAN AND VIOLET.

T

PROFESSIONAL

NE ER

IGNE

SIGER

ERED

No. 26308

IGROEG

A

A

W

R.L

NERRA

W

NORTH

WA

RN

ING

: C

ontra

ctor

s, s

ubco

ntra

ctor

s, v

endo

rs a

nd s

uppl

iers

are

adv

ised

that

the

cont

ract

doc

umen

ts c

onsi

st o

fA

rchi

tect

-rep

rodu

ced

prin

ted,

bou

nd a

nd n

umbe

red

spec

ifica

tions

, Arc

hite

ct-r

epro

duce

d pr

inte

d, b

ound

and

num

bere

dbl

ue- o

r bla

ck-li

ne p

rints

, add

enda

, pos

t-bid

add

enda

, and

cha

nge

orde

rs o

nly.

Doc

umen

ts re

prod

uced

by

parti

es o

ther

than

the

Arc

hite

ct, w

heth

er in

har

d co

py o

r in

elec

troni

c fo

rmat

, sha

ll no

t be

cons

ider

ed p

art o

f the

con

tract

doc

umen

ts a

nddo

not

sup

erse

de th

e pr

ovis

ions

of t

he c

ontra

ct d

ocum

ents

. T

he c

ontra

ctor

, sub

cont

ract

ors,

ven

dors

and

sup

plie

rs a

reso

lely

resp

onsi

ble

for v

erifi

catio

n th

at in

form

atio

n ut

ilize

d in

bid

ding

, dev

elop

men

t of s

hop

draw

ings

, and

con

stru

ctio

n of

the

faci

lity

are

iden

tical

to th

e co

ntra

ct d

ocum

ents

.

PROJECT NUMBER

PROJECT DATE

APPROVED BY

CHECKED BY

DRAWN BY

Copyright (c) 2008All Rights Reserved.

ISSUED FOR:

NOT VALID UNLESS SIGNED

JAM

ES

W.

BU

CK

LE

Y &

AS

SO

CIA

TE

S I

NC

. --

AR

CH

ITE

CT

SS

WA

INS

BO

RO

, A

LB

AN

Y,

RO

ME

, S

AV

AN

NA

H A

ND

AT

HE

NS

GE

OR

GIA

SHEET

NUMBER:

KEY PLAN - LEVEL 1 3/11

/201

6 11

:25:

42 A

ME

:\$A

CTI

VE

JO

BS

\Hav

en E

lem

enta

ry\2

0151

027E

LEC

-Hav

en-G

jc.rv

t

SE

CU

RIT

Y S

YS

TE

MS

PLA

N -

LE

VE

L 1

HA

VE

N E

LE

ME

NT

AR

Y

03-11-2016

11415

WAL

WAL

GJC

FINAL

SA

VA

NN

AH

S

AV

AN

NA

H-C

HA

TH

AM

CO

UN

TY

PU

BLIC

SC

HO

OL S

YS

TE

M G

EO

RG

IAS

CH

OO

L C

OD

E: 625-0

131

T3.0

SCALE: 1/16" = 1'-0"T3.0

1 SECURITY SYSTEMS - LEVEL 1

SCALE:NOT TO SCALET3.0

2 ACCESS CONTROL DOOR DETAIL

SCALE: 1/8" = 1'-0"T3.0

3 DOOR LOCK CONNECTIONS

GENERAL: WHERE DOOR ISLOCATED IN SPACE WITHCEILING ABOVE 10'-0" OR INSPACE WITH NON-ACCESSIBLE CEILING:POWER SUPPLY SHALL BELOCATED ON WALL ABOVENEAREST 10'-0" (ORLOWER) ACCESSIBLECEILING WHERE INDICATEDOR WITHIN 75' OF DOORBEING SERVED. LOCATIONSOF ALL POWER SUPPLIESSHALL BE NOTED ON AS-BUILT DRAWINGS.

CR

DPS DPS

.

FD FD

FD

FDFD

FD FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD FD

FD FD

FD

FD

FD

AC

DA

CS

INTRUSION ALARM

CONTROL PANEL

CLASSROOM

2502

3RD GRADE

2505

EIP

2501

5TH GRADE

2412

4TH GRADE

2406

5TH GRADE

2407

4TH GRADE

2403

WOMEN

2404.1

VEST.

2404

MEN

2404.2

TEACHER RESOURCE

2404.33RD GRADE

2508

CLOSET

2402.2

CONFERENCE

2402

ELEC.

2402.1

MECH

2500.2

4TH GRADE

2408

5TH GRADE

2410

5TH GRADE

2405

BOOK STOR.

2400.1

4TH GRADE

2401

T.

2410.2

VEST

2410.1

MECH

2400.4

T.

2410.3

T.

2406.2

VEST

2406.1

MECH

2400.2

T.

2406.3

MECH

2400.5

T.

2405.3

T.

2405.2

VEST.

2405.1

MECH

2400.3

T.

2401.3

T.

2401.2

VEST

2401.1

3RD GRADE

2504

GIFTED

2503

3RD GRADE

2507

T.

2502.2

VEST

2502.1

MECH

2500.4

T.

2502.3

MECH

2500.1

T.

2501.3

T.

2501.2

VEST

2501.1

MECH

2500.3

T.

2505.3

T.

2505.2

VEST

2505.1

3RD GRADE

2506

T.

2506.2

VEST

2506.1

T.

2506.3

MECH

2500.6

STAIR

2000.3

COMPUTER LAB

2112

HALLWAY

2000.1

TV BROADCAST

2116

WORKROOM

2104

PROF. INST.

RESOURCES

2105

ATHLETICS MEZZANINE

2220

DATA - MDF

2200.8

JAN.

2200.4

VEST.

2204

MECH

2200.5

JAN. OFF.

2200.10

CORRIDOR

2400 CORRIDOR

2500

CORRIDOR

2300

LEARNING

2103

ELEC.

2114

SCIENCE LAB

2208

AP

2212

SPED

2210

T.

2204.2

T.

2204.1

BEHAVIORAL

SPECIALIST

2205

MATH LAB

2203

WRITING LAB

2201

STORAGE

2407.1

STORAGE

2507.1

DATA

2300.1

MECH

2200.3

VEST.

2201.1

T.

2201.2

T.

2201.3

EQUIP.

2000.2

VEST.

2205.1

T.

2205.3

T.

2205.2

MECH

2204.3

LAB STOR.

2208.1

CORRIDOR

2000

CORRIDOR

2200

CR

OFFICE

2102

CLOSET

2102.1

EQ. STOR.

2106WOMEN

2108

MEN

2110

STORYTELLING

2101MEDIA CENTER

2100

ELEC.

2200.6

T

PROFESSIONAL

NE ER

IGNE

SIGER

ERED

No. 26308

IGROEG

A

A

W

R.L

NERRA

W

NORTH

WA

RN

ING

: C

ontra

ctor

s, s

ubco

ntra

ctor

s, v

endo

rs a

nd s

uppl

iers

are

adv

ised

that

the

cont

ract

doc

umen

ts c

onsi

st o

fA

rchi

tect

-rep

rodu

ced

prin

ted,

bou

nd a

nd n

umbe

red

spec

ifica

tions

, Arc

hite

ct-r

epro

duce

d pr

inte

d, b

ound

and

num

bere

dbl

ue- o

r bla

ck-li

ne p

rints

, add

enda

, pos

t-bid

add

enda

, and

cha

nge

orde

rs o

nly.

Doc

umen

ts re

prod

uced

by

parti

es o

ther

than

the

Arc

hite

ct, w

heth

er in

har

d co

py o

r in

elec

troni

c fo

rmat

, sha

ll no

t be

cons

ider

ed p

art o

f the

con

tract

doc

umen

ts a

nddo

not

sup

erse

de th

e pr

ovis

ions

of t

he c

ontra

ct d

ocum

ents

. T

he c

ontra

ctor

, sub

cont

ract

ors,

ven

dors

and

sup

plie

rs a

reso

lely

resp

onsi

ble

for v

erifi

catio

n th

at in

form

atio

n ut

ilize

d in

bid

ding

, dev

elop

men

t of s

hop

draw

ings

, and

con

stru

ctio

n of

the

faci

lity

are

iden

tical

to th

e co

ntra

ct d

ocum

ents

.

PROJECT NUMBER

PROJECT DATE

APPROVED BY

CHECKED BY

DRAWN BY

Copyright (c) 2008All Rights Reserved.

ISSUED FOR:

NOT VALID UNLESS SIGNED

JAM

ES

W.

BU

CK

LE

Y &

AS

SO

CIA

TE

S I

NC

. --

AR

CH

ITE

CT

SS

WA

INS

BO

RO

, A

LB

AN

Y,

RO

ME

, S

AV

AN

NA

H A

ND

AT

HE

NS

GE

OR

GIA

SHEET

NUMBER:

KEY PLAN - LEVEL 2 3/11

/201

6 11

:25:

52 A

ME

:\$A

CTI

VE

JO

BS

\Hav

en E

lem

enta

ry\2

0151

027E

LEC

-Hav

en-G

jc.rv

t

SE

CU

RIT

Y S

YS

TE

MS

PLA

N -

LE

VE

L 2

HA

VE

N E

LE

ME

NT

AR

Y

03-11-2016

11415

WAL

WAL

GJC

FINAL

SA

VA

NN

AH

S

AV

AN

NA

H-C

HA

TH

AM

CO

UN

TY

PU

BLIC

SC

HO

OL S

YS

TE

M G

EO

RG

IA

SC

HO

OL C

OD

E: 625-0

131

T3.1

SCALE: 1/16" = 1'-0"T3.1

1 SECURITY SYSTEMS - LEVEL 2