Maintenance LED Indication Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. © 2009-2013 SMC Corporation All Rights Reserved Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku,Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362 URL http://www.smcworld.com Troubleshooting EX※※-OMK0001-B Refer to the operation manual from SMC website (URL http://www.smcworld.com ) for more information about troubleshooting. Dimensions Switch Setting Open the switch protective cover and set the switches with a sharp-pointed watchmakers screwdriver etc. 5 6 7 0 - - 1 - - 1 0 - 1 1 - 1 - 0 1 - 1 SW1 SW1 8 0 1 1 2 3 4 5 6 7 8 ON 1 0 Remote control X : 3 2 1 14 DHCP mode 1 2 3 4 0 0 0 0 1 0 0 0 0 1 0 0 1 1 0 0 : : : : 0 1 1 1 1 1 1 1 SW1 SW1 CLEAR/HOLD IP address 192.168.0.X Manual set up of IP address Description Item Communication setting Communication speed Communication method AUTO: The communication setting is automatically selected. MANUAL: The communication setting follows the setting result by the switch No. 6 and No. 7. Communicated at 100 Mbps Communicated at 10 Mbps Communicated at half duplex Communicated at full duplex Communication setting Description The output signal is cleared when the communication error occurs. The output signal is held when the communication error occurs. NOTE 1. Be sure to turn off the power supply before setting the switches. 2. Be sure to set these switches before use. 3. After setting the switch, close the switch protective cover and tighten the screws with proper tightening torque. (Tightening torque: 0.6 Nm) •Remote control (SW1 Dip switches 1-4 OFF) SMC's EX250 SI Unit will respond to the following Rockwell Automation BOOTP/DHCP Server commands. Enable DHCP Selecting this function will enable the EX250 SI Unit to retrieve its IP addressfrom the BOOTP/DHCP Server. If DHCP is enabled the EX250 SI Unit will retrieve its IP addressduring the next power up. If the IP addressis not acquired after approximately 30 seconds from when the power is supplied, the previous IP addressfrom immediately before will be set. Disable BOOTP/DHCP Selecting this function will disable the EX250 from retrieving its IP addressfrom the BOOTP/DHCP Server, and will cause the EX250 to retain its current configuration during the next power up. •DHCP mode (SW1 Dip switches 1-4 ON) The IP addressis acquired from the DHCP Server. If the IP addressis not acquired after approximately 30 seconds from when the power is supplied, the previous IP addressfrom immediately before will be set. The IP addresswill be lost if the power supply is disconnected. •Manual set up of IP address The IP addressrange is 192.168.0.1 to 192.168.0.14. : Information such as the subnet masks is included. Default settings At the time of factory shipment, the product is in "Remote Control Mode" and set to "Enable DHCP". NOTE If the stored address of an EX250 is not known, please go to the "DHCP Mode" section. Display Description Insufficient power supply for input and control Insufficient power supply for solenoids Normal power supply for solenoids Normal power supply for input and control Setting error (Device has not been configured) The power supply for control is OFF Operating normally Recoverable internal error Unrecoverable internal error The power supply for control is OFF or IP address not set Multiple EtherNet/IP TM -level communications time out EtherNet/IP TM -level communication not established Multiple EtherNet/IP TM -level communications established IP address duplicated OFF OFF Green light ON Green light ON Green flashes OFF Green light ON Red flashes Red light ON OFF Red flashes Green flashes Green light ON Red light ON SOL PWR MS NS Refer to the operation manual from SMC website (URL http://www.smcworld.com ) for more information about maintenance. Specifications Refer to the operation manual from SMC website (URL http://www.smcworld.com ) for more information about dimensions. Power for SI Unit/Input Block: 24 VDC ±20%, 1.1 A or less Inside of SI Unit: 0.1 A or less Input block: 1 A or less (Depending on number of connecting sensors and specifications) Power for solenoid valve: 24 VDC +10%/-5%, 2 A or less (Depending on number of solenoid valve station and specifications) Connection load: Solenoid valve with protection circuit for 24 VDC and 1.5 W or less surge voltage. (made by SMC) Operating ambient temp: 5 to 45 o C Storage ambient temp: -20 to +60 o C Pollution degree: Pollution degree 3 (UL508) Technical documentation giving detailed specification information can be found on the SMC website (URL http://www.smcworld.com ). ) ( Fieldbus device Operation Manual EX250 Series for EtherNet/IP TM Safety Instructions Safety Instructions Summary of Product parts Mounting and Installation CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning: Danger: WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Thank you for purchasing an SMC EX250 series Fieldbus device (Hereinafter referred to as "SI Unit" ). Please read this manual carefully before operating the product and make sure you understand its capabilities and limitations. Please keep this manual handy for future reference. These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International standards (ISO/IEC) and other safety regulations. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. If using the product in an interlocking circuit: •Provide a double interlocking system, for example a mechanical system. •Check the product regularly for proper operation. Otherwise malfunction can result, causing an accident. The following instructions must be followed during maintenance: •Turn off the power supply. •Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance. Otherwise an injury can result. After maintenance is complete, perform appropriate functional inspections. Stop operation if the equipment does not function properly. Safety cannot be assured in the case of unexpected malfunction. When handling the unit or assembling/replacing units: •Do not touch the sharp metal parts of the connector or plug for connecting units. •Take care not to hit your hand when disassembling the unit. The connecting portions of the unit are firmly joined with seals. •When joining units, take care not to get fingers caught between units. An injury can result. Warning Caution Operator The operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are allowed to perform assembly, operation and maintenance. Read and understand the operation manual carefully before assembling, operating or providing maintenance to the product. NOTE •The direct current power supply to combine should be UL1310 Class2 power supply when conformity to UL is necessary. To obtain the operation manual about this product, please refer to the SMC website (URL http://www.smcworld.com ) or contact SMC directly. Refer to the operation manual EX250-IE1 / -IE2 / -IE3 for the input block specifications, and EX9-OET1 / -OET2 / -OEP1 / -OEP2 / PE1 for the output block and power block specifications. Provide grounding to assure the safety and noise resistance of the Fieldbus system. Individual grounding should be provided close to the product with a short cable. 66 L2 = 21 x m + 89.8 L1 = 10.5 x n + 45 The number of Input Brocks = m (pcs.) M4 x 6 Thickness: 13.2 The number of solenoids = n (pcs.) 45 0 89.8 L1 L2 Element Description Communication connector Input block connector Power supply connector Output block connector Display Switch protective cover MAC address Ground terminal Communication connector Connect the EtherNet/IP TM line. n,m L 55.5 1 110.8 66 2 131.8 76.5 3 152.8 87 4 173.8 97.5 5 194.8 108 6 215.8 118.5 7 236.8 129 8 257.8 139.5 9 278.8 150 10 299.8 160.5 11 L1 n,m L 171 12 181.5 13 192 14 202.5 15 213 16 [mm] 66 L3 = 21 x m + 93 M4 x 4 Thickness: 13.2 The number of Output Blocks and Power Blocks The number of Input Blocks Installation example: With output block connected : The number of Input Blocks + The number of Output Blocks + The number of Power Blocks: m Tie-rod (2 pcs.) Accessory 114 L3 : L1 shows the dimensions of the VQC1000 series solenoid valve. : Each dimension shows the SI Unit without solenoid valves connected and with the end plate R (on the Output block side) connected. Standard settings of L dimensions are with 10 or less m blocks. Contact SMC sales for the setting with over 10 blocks mounted. 135 156 177 198 219 240 261 282 303 Installation Installation example: With solenoid valve connected 2. Ground terminal Connect the ground terminal to ground. Resistance to ground should be 100 ohms or less. Wiring Wiring (for power supply, communication, input and output) and piping are done on only one side. On the side, make a space for wiring and piping. 2 4 3 1 SI unit communication connector pin layout Cable connection 1) Aligning the key groove with the communication connector (4-pin, socket) of SI Unit, plug the Ethernet communication cable (plug). 2) Tighten the lock nut on the cable side by turning it clockwise by hand. 3) Confirm that the connector does not move. M12 RJ45 +Tx +Rx -Tx -Rx 1 2 3 4 1 White/Orange 2 Orange 3 White/Green 4 5 6 Green 7 8 Terminal No. Cable core wire external color Wiring diagram Shield 1 2 4 6 8 3 5 7 Pin assignment of plug connector Pin layout and connection diagram of Ethernet communication cable Model No.: EX9-AC EN-PSRJ Cable specifications Core wire AWG26 Sheath color Blue green Refer to "Media Planning and Installation Manual" of ODVA for detail of Wiring. M12 Connecting one or two power supplies to SI Unit Both of single power supply and two power supply systems can be adopted, however, the wiring should be made separately (for solenoid valves/output and for input and control) for both systems. 2 4 3 1 5 Socket connector pin layout 24 VDC 24 VDC 1 4 3 2 5 Brown: 24 VDC (for solenoid valves/output) White : 0 V (for solenoid valves/output) Blue : 24 VDC (for input and controlling) Black : 0 V (for input and controlling) Power supply connector Power cable 24 VDC 1 4 3 2 5 Power supply connector Power cable Brown: 24 VDC (for solenoid valves/output) White : 0 V (for solenoid valves/output) Blue : 24 VDC (for input and controlling) Black : 0 V (for input and controlling) 3. Power supply wiring Connect the power supply cable to the power supply connector of SI Unit. M3 ground terminal Cable connection 1) Aligning the key groove with the power supply connector (plug) of SI Unit, plug the power supply cable (socket). 2) Tighten the lock nut on the cable side by turning it clockwise by hand. 3) Confirm that the connector does not move. NOTE D class grounding (with the ground resistance of 100 ohm or less) should be performed for ground terminal, and ground at one point. Pin layout and connection diagram of power supply connector cable (unit: mm) Model No.: EX500-AP -S Model No.: PCA-140180 Pin No. 1 2 Brown: 24 VDC +10%/-5% (for solenoid valves/output) Cable color: Signal name White: 0 V (for solenoid valves/output) 3 4 Blue: 24 VDC ±10% (for input and control) Black: 0 V (for input and control) 5 Gray: Not connected M12 SPEEDCON 2 4 3 1 5 Socket connector pin layout Pin No. 1 2 Brown: 24 VDC +10%/-5% (Solenoid valve power supply) Cable color: Signal name White: 0 V (Solenoid valve power supply) 3 4 Blue: 24 VDC ±10% (Control power supply) Black: 0 V (Control power supply) 5 Green / Yellow: Not connected A. Two power supplies B. Single power supply Power supply connector Supplies power to the solenoid valve, Output block, SI Unit and Input block. Input block connector Connects the Input block. Output block connector Connects the solenoid valve, Output block, etc. Display LED display showing the SI Unit status. Switch protective cover Incorporates the internal switch setting IP address and communication method. Ground terminal Used for grounding. MAC address A unique MAC address of 12 hexadecimal number digits to each SI Unit. 1. Communication wiring Connect the Ethernet communication cable to the communication connector of SI Unit. 1 4 3 2 Pin assignment of plug connector

Upload: ngophuc

Post on 18-May-2018

215 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: ˆ+’& ˆ&,ˆ$ ˇ)& 3 . ’ ˚ )*, ($0 & - SMC株式会社 · 4 173.8 97.5 5 194.8 108 6 215.8 118.5 7 236.8 129 8 257.8 139.5 9 ... 4 6 8 3 5 7 Pin assignment of ... 3 4 2 5 Power

Maintenance

LED Indication

Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.© 2009-2013 SMC Corporation All Rights Reserved

Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPANPhone: +81 3-5207-8249 Fax: +81 3-5298-5362

URL http://www.smcworld.com

Troubleshooting

EX※※-OMK0001-B

Refer to the operation manual from SMC website (URL http://www.smcworld.com) for moreinformation about troubleshooting.

Dimensions

Switch SettingOpen the switch protective cover and set the switches with a sharp-pointed watchmakersscrewdriver etc.

5 6 70 - -

1 - -

1 0 -1 1 -1 - 01 - 1

SW1

SW1801

1 2 3 4 5 6 7 8

ON1

0

Remote control

X

:321

14DHCP mode

1 2 3 40 0 0 01 0 0 00 1 0 01 1 0 0: : : :0 1 1 11 1 1 1

SW1

SW1

CLEAR/HOLD

IP address192.168.0.X

Manual set up of IP address

DescriptionItem

Communicationsetting

Communicationspeed

Communicationmethod

AUTO: The communication setting is automatically selected.MANUAL: The communication setting follows the setting result by the switch No. 6 and No. 7.

Communicated at 100 MbpsCommunicated at 10 Mbps

Communicated at half duplexCommunicated at full duplex

Communicationsetting

Description

The output signal is cleared when the communication error occurs.The output signal is held when the communication error occurs.

NOTE1. Be sure to turn off the power supply before setting the switches.2. Be sure to set these switches before use.3. After setting the switch, close the switch protective cover and tighten the screws with

proper tightening torque. (Tightening torque: 0.6 Nm)

•Remote control (SW1 Dip switches 1-4 OFF)SMC's EX250 SI Unit will respond to the following Rockwell Automation BOOTP/DHCPServer commands.

Enable DHCPSelecting this function will enable the EX250 SI Unit to retrieve its IP address∗ from theBOOTP/DHCP Server. If DHCP is enabled the EX250 SI Unit will retrieve its IP address∗during the next power up.If the IP address∗ is not acquired after approximately 30 seconds from when the power issupplied, the previous IP address∗ from immediately before will be set.

Disable BOOTP/DHCPSelecting this function will disable the EX250 from retrieving its IP address∗ from theBOOTP/DHCP Server, and will cause the EX250 to retain its current configuration duringthe next power up.

•DHCP mode (SW1 Dip switches 1-4 ON)The IP address∗ is acquired from the DHCP Server. If the IP address∗ is not acquired afterapproximately 30 seconds from when the power is supplied, the previous IP address∗ fromimmediately before will be set. The IP address∗ will be lost if the power supply isdisconnected.

•Manual set up of IP address∗The IP address∗ range is 192.168.0.1 to 192.168.0.14.

∗: Information such as the subnet masks is included.

Default settingsAt the time of factory shipment, the product is in "Remote Control Mode" and set to "EnableDHCP".

NOTEIf the stored address of an EX250 is not known, please go to the "DHCP Mode" section.

Display Description

Insufficient power supply for input and control

Insufficient power supply for solenoids

Normal power supply for solenoids

Normal power supply for input and control

Setting error (Device has not been configured)

The power supply for control is OFF

Operating normally

Recoverable internal error

Unrecoverable internal error

The power supply for control is OFF or IP address not set

Multiple EtherNet/IPTM-level communications time out

EtherNet/IPTM-level communication not established

Multiple EtherNet/IPTM-level communications established

IP address duplicated

OFF

OFF

Green light ON

Green light ON

Green flashes

OFF

Green light ON

Red flashes

Red light ON

OFF

Red flashes

Green flashes

Green light ON

Red light ON

SOL

PWR

MS

NS

Refer to the operation manual from SMC website (URL http://www.smcworld.com) for moreinformation about maintenance.

Specifications

Refer to the operation manual from SMC website (URL http://www.smcworld.com) for moreinformation about dimensions.

Power for SI Unit/Input Block: 24 VDC ±20%, 1.1 A or lessInside of SI Unit: 0.1 A or lessInput block: 1 A or less (Depending on number of connecting

sensors and specifications)Power for solenoid valve: 24 VDC +10%/-5%, 2 A or less

(Depending on number of solenoid valve station andspecifications)

Connection load: Solenoid valve with protection circuit for 24 VDC and 1.5 W or less surgevoltage. (made by SMC)

Operating ambient temp: 5 to 45 oC Storage ambient temp: -20 to +60 oCPollution degree: Pollution degree 3 (UL508)

Technical documentation giving detailed specification information can be found on the SMCwebsite (URL http://www.smcworld.com).

)(

Fieldbus device

Operation ManualEX250 Series for EtherNet/IPTM

Safety Instructions

Safety Instructions

Summary of Product parts

Mounting and Installation

CAUTION indicates a hazard with a low level of risk which, ifnot avoided, could result in minor or moderate injury.Caution:

Warning:

Danger:

WARNING indicates a hazard with a medium level of riskwhich, if not avoided, could result in death or serious injury.

DANGER indicates a hazard with a high level of risk which, ifnot avoided, will result in death or serious injury.

Thank you for purchasing an SMC EX250 series Fieldbus device (Hereinafterreferred to as "SI Unit" ).Please read this manual carefully before operating the product and make sure youunderstand its capabilities and limitations. Please keep this manual handy forfuture reference.

These safety instructions are intended to prevent hazardous situations and/orequipment damage.These instructions indicate the level of potential hazard with the labels of"Caution", "Warning" or "Danger". They are all important notes for safety and mustbe followed in addition to International standards (ISO/IEC) and other safetyregulations.

Do not operate the product outside of the specifications.Do not use for flammable or harmful fluids.Fire, malfunction, or damage to the product can result.Verify the specifications before use.

Do not disassemble, modify (including changing the printed circuit board) or repair.An injury or failure can result.

Do not operate in an atmosphere containing flammable or explosive gases.Fire or an explosion can result.This product is not designed to be explosion proof.

If using the product in an interlocking circuit:•Provide a double interlocking system, for example a mechanical system.•Check the product regularly for proper operation.Otherwise malfunction can result, causing an accident.

The following instructions must be followed during maintenance:•Turn off the power supply.•Stop the air supply, exhaust the residual pressure and verify that the air is released before performingmaintenance.

Otherwise an injury can result.

After maintenance is complete, perform appropriate functional inspections.Stop operation if the equipment does not function properly.Safety cannot be assured in the case of unexpected malfunction.

When handling the unit or assembling/replacing units:•Do not touch the sharp metal parts of the connector or plug for connecting units.•Take care not to hit your hand when disassembling the unit.The connecting portions of the unit are firmly joined with seals.

•When joining units, take care not to get fingers caught between units.An injury can result.

Warning

Caution

Operator

The operation manual is intended for those who have knowledge of machineryusing pneumatic equipment, and have sufficient knowledge of assembly,operation and maintenance of such equipment. Only those persons areallowed to perform assembly, operation and maintenance.Read and understand the operation manual carefully before assembling,operating or providing maintenance to the product.

NOTE•The direct current power supply to combine should be UL1310 Class2 power supplywhen conformity to UL is necessary.

To obtain the operation manual about this product, pleaserefer to the SMC website (URL http://www.smcworld.com) or

contact SMC directly.Refer to the operation manual EX250-IE1 / -IE2 / -IE3 for the

input block specifications,and EX9-OET1 / -OET2 / -OEP1 / -OEP2 / PE1 for the output

block and power block specifications.

Provide grounding to assure the safety and noise resistance of the Fieldbus system.Individual grounding should be provided close to the product with a short cable.

66

L2 = 21 x m + 89.8 L1 = 10.5 x n + 45

The number of Input Brocks= m (pcs.)

M4 x 6Thickness: 13.2

The number of solenoids= n (pcs.)

45

0

89.8

L1

L2

Element Description

Communication connector

Input block connector

Power supply connector

Output block connector

Display

Switch protective cover

MAC address

Ground terminal

Communication connector Connect the EtherNet/IPTM line.

n,mL

55.5

1

110.8

66

2

131.8

76.5

3

152.8

87

4

173.8

97.5

5

194.8

108

6

215.8

118.5

7

236.8

129

8

257.8

139.5

9

278.8

150

10

299.8

160.5

11

L1

n,mL

171

12

181.5

13

192

14

202.5

15

213

16

[mm]

66

L3 = 21 x m + 93

M4 x 4Thickness: 13.2

The number of Output Blocks and Power Blocks

The number of Input Blocks

Installation example: With output block connected

∗: The number of Input Blocks + The number of Output Blocks + The number of Power Blocks: m

Tie-rod (2 pcs.)Accessory

114L3

∗: L1 shows the dimensions of the VQC1000 series solenoid valve.∗: Each dimension shows the SI Unit without solenoid valves connected and with the end plate R (on the Output

block side) connected.Standard settings of L dimensions are with 10 or less m blocks. Contact SMC sales for the setting with over 10blocks mounted.

135 156 177 198 219 240 261 282 303

InstallationInstallation example: With solenoid valve connected

2. Ground terminalConnect the ground terminal to ground.Resistance to ground should be 100 ohms or less.

WiringWiring (for power supply, communication, input and output) and piping are done on onlyone side.On the side, make a space for wiring and piping.

2

4 3

1

SI unit communicationconnector pin layout

Cable connection1) Aligning the key groove with the communication connector (4-pin, socket) of SI Unit,

plug the Ethernet communication cable (plug).2) Tighten the lock nut on the cable side by turning it clockwise by hand.3) Confirm that the connector does not move.

M12 RJ45

+Tx+Rx-Tx-Rx

1234

1 White/Orange2 Orange3 White/Green456 Green78

Terminal No.Cable core wireexternal color

Wiring diagram Shield

1

2

4

6

8

3

5

7Pin assignment of

plug connector

Pin layout and connection diagram of Ethernet communication cableModel No.: EX9-AC EN-PSRJ

Cable specifications

Core wire AWG26

Sheath color Blue green

Refer to "Media Planning and Installation Manual" of ODVA for detail of Wiring.

M12

Connecting one or two power supplies to SI UnitBoth of single power supply and two power supply systems can be adopted, however,the wiring should be made separately (for solenoid valves/output and for input andcontrol) for both systems.

2

4 3

1

5

Socket connector pin layout

24 VDC

24 VDC

1

43

25

Brown: 24 VDC (for solenoid valves/output) White : 0 V (for solenoid valves/output)

Blue : 24 VDC (for input and controlling)Black : 0 V (for input and controlling)

Power supplyconnector

Power cable

24 VDC1

43

25

Power supplyconnector

Power cableBrown: 24 VDC (for solenoid valves/output) White : 0 V (for solenoid valves/output)

Blue : 24 VDC (for input and controlling)Black : 0 V (for input and controlling)

3. Power supply wiringConnect the power supply cable to the power supply connector of SI Unit.

M3 ground terminal

Cable connection1) Aligning the key groove with the power supply connector (plug) of SI Unit, plug the

power supply cable (socket).2) Tighten the lock nut on the cable side by turning it clockwise by hand.3) Confirm that the connector does not move.

NOTED class grounding (with the ground resistance of 100 ohm or less) should be performed forground terminal, and ground at one point.

Pin layout and connection diagram of power supply connector cable (unit: mm)Model No.: EX500-AP -S

Model No.: PCA-140180

Pin No.

1

2

Brown: 24 VDC +10%/-5% (for solenoid valves/output)

Cable color: Signal name

White: 0 V (for solenoid valves/output)

3

4

Blue: 24 VDC ±10% (for input and control)

Black: 0 V (for input and control)

5 Gray: Not connected

M12SPEEDCON

2

4 3

1

5

Socket connector pin layout

Pin No.

1

2

Brown: 24 VDC +10%/-5% (Solenoid valve power supply)

Cable color: Signal name

White: 0 V (Solenoid valve power supply)

3

4

Blue: 24 VDC ±10% (Control power supply)

Black: 0 V (Control power supply)

5 Green / Yellow: Not connected

A. Two power supplies

B. Single power supply

Power supply connector Supplies power to the solenoid valve, Output block, SI Unit and Input block.

Input block connector Connects the Input block.

Output block connector Connects the solenoid valve, Output block, etc.

Display LED display showing the SI Unit status.

Switch protective cover Incorporates the internal switch setting IP address and communication method.

Ground terminal Used for grounding.

MAC address A unique MAC address of 12 hexadecimal number digits to each SI Unit.

1. Communication wiringConnect the Ethernet communication cable to the communication connector of SI Unit.

1

43

2

Pin assignment ofplug connector