© abb group - 1 - 20-aug-15 product choice offered by abb oy, distribution automation jan...
TRANSCRIPT
© A
BB
Gro
up
- 1
-A
pr
19
, 2
02
3
Product choice offered byABB Oy, Distribution Automation
Jan Kulczynski
© F
ISU
B 2
/ 22
Mic
roS
CA
DA
Par
tner
s C
lub.
ppt 0
2.04
.200
7
Distribution Automation – Content
Introduction & overview of Distribution Automation
Product range
Protection relays & terminals
Simulator
Communication
Commitment to new standard IEC61850
Training, Support & Service
© F
ISU
B 3
/ 22
Mic
roS
CA
DA
Par
tner
s C
lub.
ppt 0
2.04
.200
7
ABB Oy Distribution Automation
Global market leader in protection relay sales
~275 employees, ~120 R&D engineers
Turnover ~90 million euros (in 2006)
> 500 000 SPACOM units installed
> 120 000 units of 500-series installed.
A reliable distribution of electricity helps preserving the environment
© F
ISU
B 4
/ 22
Mic
roS
CA
DA
Par
tner
s C
lub.
ppt 0
2.04
.200
7
The Role of the Vaasa Unit within ABB
Global responsibility for the development and marketing of protection relays software tools communication devicesfor Distribution Automation
Worldwide responsibility for the sales of products (with local sales units)
Responsible for the development of technology and solutions.
© F
ISU
B 5
/ 22
Mic
roS
CA
DA
Par
tner
s C
lub.
ppt 0
2.04
.200
7
Distribution Automation – Content
Introduction & overview of Distribution Automation
Product range
Protection relays & terminals
Simulator
Communication
Commitment to new standard IEC61850
Training, Support & Service
© F
ISU
B 6
/ 22
Mic
roS
CA
DA
Par
tner
s C
lub.
ppt 0
2.04
.200
7
© F
ISU
B 7
/ 22
Mic
roS
CA
DA
Par
tner
s C
lub.
ppt 0
2.04
.200
7
Production Part of the Delivery Process
Logistics
Supply Management
Order handling
&productionplanning
Collectionof
customerorders
Production PackingShipping
&invoicing
Transportation
Manufacturing
Supporting Functions Production testing engineering Product maintenance License manufacturing: India, Malaysia, Russia, China
© F
ISU
B 8
/ 22
Mic
roS
CA
DA
Par
tner
s C
lub.
ppt 0
2.04
.200
7
Distribution Automation – Content
Introduction & overview of Distribution Automation
Product range
Protection relays & terminals
Simulator
Communication
Commitment to new standard IEC61850
Training, Support & Service
© F
ISU
B 9
/ 22
Mic
roS
CA
DA
Par
tner
s C
lub.
ppt 0
2.04
.200
7
SPACOM
SPACOM
500 Series
REJ-REUREA REF 542plusREX RE_ 541/3/5
Distribution Automation – Product range
REU 610REF 610
600 Series
REM 610
© F
ISU
B 1
0/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
SPACOM
SPACOM
REM 610REF 610
600 Series
Distribution Automation – Product range
500 Series
REJ-REUREA REF 542plusREX RE_ 541/3/5
REU 610
SPACOM
© F
ISU
B 1
1/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
SPACOM SeriesSPACOM
Complete range of relays: Feeder protection Motor protection Voltage protection Transformer protection Capacitor bank protection
Annunciator systems Analogue input systems On-off input systems
Produced, delivered and supported, but not actively promoted.
© F
ISU
B 1
2/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
DA products deliveries Deliveries
1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006ORDERS 1994ORDERS 1995ORDERS 1996ORDERS 1997ORDERS 1998ORDERS 1999ORDERS 2000ORDERS 2001ORDERS 2002ORDERS 2003ORDERS 2004ORDERS 2005ORDERS 2006
PCS PCS PCS PCS PCS PCS PCS PCS PCS PCS PCS PCS PCSSPAJ 135 212 384 708 356 122 158 237 456 45 45 53 176 19SPAJ 140 10,537 10,356 9186 9779 9673 10675 10594 11201 13377 13629 12270 6595 3833SPAJ 141 1,314 1,479 1417 1663 1260 1220 1225 1358 863 1012 960 806 769SPAJ 142 1,538 1,143 1192 1293 1242 1262 579 2049 1584 2132 2014 1481 794SPAJ 144 0 30 323 1029 999 933 1365 1186 462 582 543 455 403
SPACOM 100 series > 400 000 pcs
WORLD LEADER SPAJ 14_ C > 270 000 pcs
© F
ISU
B 1
3/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Disturbance Recorder Module SPCR 8C27
Features
Recorder with 8 analog and 8 digital channels
Tool to analyze network behaviour in fault situations
Helps to locate disturbances
Makes it easier to find correct settings for protective devices
Gives information about normal phenomenaof network ( inrush currents, etc. )
SPACOM
© F
ISU
B 1
4/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Recording capacity
Total recording time 12 s ( 55 s option ) when all channels recorded
Total time can be divided up into 24 ( 26 ) different recordings
Recordings can consist of 0 ... 100% history
Triggering moment
Disturbance Recorder Module SPCR 8C27SPACOM
© F
ISU
B 1
5/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
SPACOM
SPACOM
Distribution Automation – Product range
500 Series
REJ-REUREA REF 542plusREX RE_ 541/3/5
REM 610REF 610
600 Series
REU 610
500 Series
© F
ISU
B 1
6/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Arc protection system – REA 10_
State of the art arc protection system
Tripping time <2.5ms. Selective tripping, even when
there is arc on the busbar. Big installed base.
500 Series
Protects human beeings and equipment.
© F
ISU
B 1
7/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
© F
ISU
B 1
8/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
© F
ISU
B 1
9/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
500 Series Arc protection system – REA 10_
© F
ISU
B 2
0/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
500 Series REJ5_ and REU5_ Protection Relays
Modern protection for simple applications
Standard functions like: Disturbance recorderMeasurement functionsEvent registerCircuit breaker failure protection
Complement to other 500 series relays incl:Overcurrent / Earthfault relaysDirectional earth fault relaysOver / under voltage relays
© F
ISU
B 2
1/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Multifunction protection – REX 521
REX 521 is a multifunction relay designed for protecting feeders and motors
Power quality THD, current harmonics and voltage harmonics
up to the 13th harmonic
Advanced condition monitoring functions for the supervision of primary devices
Several pre-configured applications HMI with many languages, now also Chinese
language available Communication
SPA, LON, Modbus RTU/ASCII, IEC 60870-5-103, DNP 3.0
Profibus & IEC 61850-8 via adapters
500 Series
© F
ISU
B 2
2/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Feeder terminals – REF 541/543/545
Advanced Bay Terminals Protection functions for all applications Freely configurable Advanced condition monitoring functions Monitoring functions like:
Sags and swells Fault locator
Communication Simultaneous dual channel communication Most used protocols available
500 Series
© F
ISU
B 2
3/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Feeder terminals – REF 541/543/545
Applications for: Feeders Capacitor banks / filters Transformers Motors <40MW Generators < 80MW
500 Series
© F
ISU
B 2
4/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Motor/generator terminals – REM 543/545
Motor and generator terminal Protection functions for motor and
generator applications Freely configurable terminal Pre-configured applications prepared for
ease of use Several language variants including e.g.
Russian, Polish, Czech.. Communication
Simultaneous dual channel communication SPA, LON, Modbus RTU & ASCII Profibus & IEC 61850-8 via adapters
500 Series
© F
ISU
B 2
5/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Transformer terminals – RET 541/543/545
Transformer terminal
All-in-one solution for two-winding power transformer protection & control completing REF 541/3/5 and REM 543/5 series
Differential protection based on long field experience and well proven algorithms
On-load tap changer control, AVR
Versatile communication capabilities as in REF 541/3/5
500 Series
© F
ISU
B 2
6/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Feeder terminal – REF542plus
Feeder terminal Covers most of the needed protection functions for
feeder protection Transformer differential protection Motor Protection Distance protection for MV (5 zones)
Embedded web server Freely programmable protection functions and
generic functions available Pre-configured applications prepared for ease of
use Communication
SPA, LON, Modbus RTU, IEC 60870-5-103 Profibus & IEC 61850-8 via adapters
500 Series
© F
ISU
B 2
7/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Feeder terminal – REF542plus
Area of application Any kind of medium voltage switchgear
(Incoming feeder, Transformer, Overhead line, Motor, Busbar, ...)
Low voltage switchgear with complex automation requirements
All secondary functions are integrated in one single unit: Control Protection Measurements Monitoring Communications
500 Series
© F
ISU
B 2
8/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
High Speed Busbar transfer, SUE 3000SUE 3000
Ensuring continuous power supply to essential electrical equipment by changing over from a main to a stand-by feeder as fast as possible
Improvement of plant availability
Protection of production facilities
Prevention of costly outages
Improvement of product quality
Protection of employees and environment
© F
ISU
B 2
9/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
For power system automation
Developed for: Ring Main Units (RMUs) Overhead lines and cable feeders in
medium voltage networks Switch disconnectors and pole-mounted
disconnectors Small kiosk-type transformer substations Wind power stations
Fast fault location and network restoration
Utilisation of new or existing communication solutions
Optimised network management secures high-quality and reliable energy supply
REC 523 Remote Supervision and Control500 Series
© F
ISU
B 3
0/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
SPACOM
SPACOM
Distribution Automation – Product range
500 Series
REJ-REUREA REF 542plusREX RE_ 541/3/5
REM 610REF 610
600 Series
REU 610
600 Series
© F
ISU
B 3
1/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
RE_ 610 Series
Compact universal feeder / motor / voltage protection.
Unique draw out design. Optional arc protection Current or voltage based functions. Including:
Disturbance recorder Measurements Event register Real time clock
600 Series
© F
ISU
B 3
2/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Basic protection relay – REF 610
REF 610 protection functions:
3 stage overcurrent protection 50/51
2 stage earth fault protection 50N/51N
Thermal overload protection 49
Phase discontinuity protection 46
Circuit breaker failure protection 62BF
Arc protection as option 50/50NL
Automatic reclosing function 79
600 Series
© F
ISU
B 3
3/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Motor protection relay – REM 610600 Series
REM 610 protection functions: Thermal overload protection (49) Temperature supervision based on RTDs (49/38) Motor startup supervision (48) Cumulative motor start-up time counter (66) Short-circuit protection (50) Overcurrent protection (51) Earth-fault protection (50N/51N) Phase unbalance / phase reversal protection (46) Undercurrent (loss of load) protection (37) Circuit-breaker failure protection (62BF) Electrically latched lockout relay (86) Emergency restart
© F
ISU
B 3
4/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Over / under voltage relay – REU 610600 Series
REU 610 protection functions:
2 stage over voltage protection
2 stage under voltage protection
2 stage residual voltage protection
© F
ISU
B 3
5/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Installation example for swgr. builders
Install the case (with protective cover)
Wire up the case to the switchgear
Deliver to customer
600 Series
© F
ISU
B 3
6/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Remove protective cover
Installation example for swgr. builders
SAVINGS INCASH FLOW
Install the plug in unit
600 Series
© F
ISU
B 3
7/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
DA products deliveries Deliveries
0
10,00020,000
30,000
40,00050,000
60,000
70,00080,000
90,000
Number of Sold Units
RE_600 509 3,201 5,007
REF542 plus 6,389 8,236 9,539
RE_ TOTAL 19,452 22,086 28,556
SPACOM TOTAL 40,621 31,865 26,034
2004 2005 2006
© F
ISU
B 3
8/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
DA products deliveries since 1997
REA 10_> 8 000 pcs
REJ_/REU_> 18 000 pcs
REX 521> 22 000 pcs
REF 541/3/5> 54 000 pcs
REM 543 /545> 7 700 pcs
RET 541/3/5 > 1 200 pcs
REF 542 plus > 48 000 pcs
REC 501/523 > 2 300 pcs
Deliveries
© F
ISU
B 3
9/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Distribution Automation – Content
Introduction & overview of Distribution Automation
Product range
Protection relays & terminals
Simulator
Communication
Commitment to new standard IEC61850
Training, Support & Service
© F
ISU
B 4
0/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
NewSignal simulator – SIM600
The programmable Protection Relay Appliance SIM 600 is designed for simulating and visualizing
protection schemes and applications
Any analog or digital signal needed to simulate the function of a substation configuration, switchgear system and protection scheme can conveniently be generated with SIM 600
SIM600
© F
ISU
B 4
1/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Distribution Automation – Content
Introduction & overview of Distribution Automation
Product range
Protection relays & terminals
Simulator
Communication
Commitment to new standard IEC61850
Training, Support & Service
© F
ISU
B 4
2/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Communication Communication
© F
ISU
B 4
3/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Communication
Local Communication
Remote CommunicationTwo major areas
Gateway
Communication
© F
ISU
B 4
4/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
REX 521 Feeder Protection Relay
Note! Only one communication port and protocol can be active at a time (optical front connector can be used simultaneously, naturally).
A PROTOCOLFOR ALMOST
ANY APPLICATION
Protocol ADAPTERProfiBus DPV1 SPA-ZC 302IEC 61850-8-1 SPA-ZC 402
WITH ADAPTER
ProtocolRear port
opticalRear port
opto isolated RS-485SPA X XLON XIEC 60870-5-103 XModBus (RTU & ASCII) X XDNP 3.0 X X
INBUILT PROTOCOLS IN REX 521
OPTICAL
RS - 485
Communication
© F
ISU
B 4
5/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
X3.2 (RS-232, Non-isolated)
X3.1
SPALON
SPAIEC-103ModBusDNP 3.0
BDM
X3.3 (RS-485)
RER 123 to this port (SPA, IEC)RER 133 for ModBus, DNP 3.0
RER 103 to this port
Protocol ADAPTERProfiBus DPV1 SPA-ZC 302IEC 61850-8-1 SPA-ZC 400
WITH ADAPTER
REF 541/3/5 Feeder Terminal
Communication
Communication
© F
ISU
B 4
6/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Programming Tool CAP 50_
Setting and supervision tool for ABB's protection relays for distribution networks
CAP 505 &
SMS 510
CAP 505
CAP 505 Configuration of terminals
Setting of distribution protection
LON/SPA communication protocol
CAP 501 Setting of distribution protection
LON/SPA communication protocol
Communication
© F
ISU
B 4
7/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Station automation series COM 600
Embedded communication gateway for industry and utility substations No moving parts
Remote communication IEC 60870-5-101/104 DNP 3.0 (serial and LAN/WAN) OPC Client access allows external OPC clients to
access data gathered from IEDs SPA Router protocol enables engineering tool
access to IEDs through COM 610
Local HMI with events, alarms, settings etc. Process communication
LON/LAG SPA IEC 61850-8-1 Client IEC 60870-5-103
Communication
© F
ISU
B 4
8/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Station automation series COM 600
Indication LEDs
USB
ON/OFF
PCMCI
Compact Flash
PowerSupply
LANAudio
USB
PCI
Serial portsRS 2324
Serial portsRS 232/485
VGA
All Interfaces are accessible from the front
Communication
© F
ISU
B 4
9/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Station automation series COM 600
COM 605 Control & Monitoring Unit COM 610 Communication Gateway COM 615 Station Computer
Provides substation data to any personnel through local HMI in substation or/and to any user through WAN/LAN networks
Utilizing latest SW and HW technology SW bundled with ruggedize industrial HW Fully complaint to IEC 61850 standard Efficient and easy engineering with ABB IEDs Suitable for any indoor installation
Communication
© F
ISU
B 5
0/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Station automation series COM 600C
OM
610
Control and Monitoring
Parameter settings & DR
Local HMI
StationCommunication
NCC Communication
External OPC client
Remote parameter
setting
CO
M 6
05
COM 615
L
AN
/WA
N/
Intr
anet
/In
tern
et
Industrial Embedded Computer
Communication
© F
ISU
B 5
1/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Station automation series COM 600
UserManual
HW FW / Tools Documentation
Control & Monitoring UnitCOM 605
NCC connection
Communication GatewayCOM 610
NCC connection
Station ComputerCOM 615
Licence key based on type of OPC and product
Upgrade based on license key generation only
Communication
© F
ISU
B 5
2/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Functionality coverageCommunication
© F
ISU
B 5
3/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Gateways Overview
SPA-ZC 200/202IEC 103/SPA Gateway
SPA-ZC 100/102LON/SPA Gateway
SPA-ZC 302Profibus DPV1/SPA Gateway
SPA-ZC 400/402Ethernet Adapters
IEC 61850
Communication
© F
ISU
B 5
4/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Different communication demands
End Users, Utilities - Industries
DistributorsOEMs
Systems
Distribution Automation Products
SWG
EPC
LON BusIEC 103IEC 61850
LON BusIEC 103IEC 61850
SPA BusModbusProfbusDNP 3.0
SPA BusModbusProfbusDNP 3.0IEC 103
SPA BusModbusProfbusDNP 3.0IEC103
Communication
© F
ISU
B 5
5/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
What we can offer to our customers
Supported communication protocols / IED type
SPAIEC 60870-
5-103 Modbus DNP 3.0 LON ProfibusIEC
61850-8
SPACOM SPA-ZC 20x SPA-ZC 10x SPA-ZC 302 SPA-ZC 402
REJ, REU 52x SPA-ZC 102 SPA-ZC 302 SPA-ZC 402
REF, REM, REU 610 SPA-ZC 102 SPA-ZC 302 SPA-ZC 402
REX 521 SPA-ZC 302 SPA-ZC 402
REF 542plus SPA-ZC 302 SPA-ZC 402
REF, REM, RET 541/543/545 SPA-ZC 302 SPA-ZC 400
Supported
Supported through external converter. Some or all types verified.
Supported through external converter. NOT VERIFIED!
Not Supported
Communication
© F
ISU
B 5
6/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Communication solutions for utility
Producers have proprietary solutions which are pushed ABB “is” pushing LON Bus solution Standard for field bus communication
IEC 60870 – 5 -103 is only “standard” for IEC world DNP 3.0 is standard for ANSI world
Standards for remote communication IEC 60870 – 5 – 101 and 104 are standardized for remote communication for IEC world DNP 3.0 is standardized for remote communication for ANSI world
Variety of architecture solutions Requirements are quite clear MicroSCADA with COM500 or COM581 is a ABB solution COM 600 will enter the market soon Some markets and customers prefer RTU approach ….and IEC 61850
Communication
© F
ISU
B 5
7/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Communication solutions for IEC 61850
Communication
© F
ISU
B 5
8/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
SPA-ZC 40x Ethernet adapters
Any product with SPA interface can be connected to any IEC 61850 system
Supports IEC61850-8-1 vertical communication Horizontal communication (GOOSE) supported
for REF 541/3/5 v3.5 and SPA-ZC 400 v2.0 only.
IEC61850-6 compatible tool for SCL import & export
Connectivity concept used for easy engineering
KEMA certified
Communication
© F
ISU
B 5
9/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Ethernet interface for REF 541/3/5, REM 543/5 and RET 541/3/5 Mechanical solution optimized for RE_ 541/3/5 Mounted on the rear ports Powered from the IED Optionally fiber optic connectors to LON or SPA for
simultaneous use with IEC 61850
100Base-Fx (100Mb fiber-optic) Ethernet communication MTRJ, LC, and RJ-45 connector
SPA-ZC 40x Ethernet adaptersCommunication
© F
ISU
B 6
0/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Externally mounted Ethernet adapter for any SPA device Power supply 110 V...240 V AC/DC or 24
V...60 V DC Fiber-optic connection to the IED Plastic and glass-fiber
100Base-Fx (100Mb fiber-optic) Ethernet communication MTRJ, LC, and RJ-45 connector
SPA-ZC 40x Ethernet adaptersCommunication
© F
ISU
B 6
1/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
What is the current situation…?
IEC 61850 Standard Station level function SPA-ZC 40x *1.1 SPA-ZC 400 *2.0 SPA-ZC 402 *2.0
6, 7-2, 7-3, 7-4, 8-1 Data in Monitoring Direction
6, 7-2, 7-3, 7-4, 8-1 Commands in Control Direction
6, 8-1 SNTP Time Syncronization
N/A Parameter Setting (Transparent SPA over TCP)
6, 7-2, 7-3, 7-4, 8-1 Parameter Setting (Native IEC 61850)
N/A DR Upload (Transparent SPA over TCP)
6, 7-2, 7-3, 7-4, 8-1 DR Upload (Native IEC 61850)
6, 7-2, 7-3, 7-4, 8-1 Horizontal Communication (GOOSE)
9-2 Samples on Process Bus
Supported
Supported for Terminals having MEDREC function block
Supported for REF 541/543/545 *3.5
Not Supported
Communication
© F
ISU
B 6
2/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Parameters setting and Disturbance record upload SPA-ZC 400: When offering those functions you must be aware what
a tool or the system will be used to set the parameters. On the tools/system side this functionality is supported by just MicroSCADA and the CAP 50x release 2.4.0.
SPA-ZC 402: When offering those functions you must be aware what a tool or the system will be used to set the parameters. On the tools/system side this functionality is supported by just MicroSCADA and the CAP 50x release 2.4.0. The CAP 50x release 2.4.0 supports just RE_ 5__ IEDs.
Availability of connectivity packages
What is the current situation…?Communication
© F
ISU
B 6
3/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Engineering of IEC 61850 system
REx 541/543/545+
SPA-ZC 400
REX 521+
SPA-ZC 402
IEC
61850-8-1
LO
N o
r SP
A
(Op
tion
al) IEC
61850-8-1
Po
wer
SPA
Communication
© F
ISU
B 6
4/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Engineering of IEC 61850 system
REx 541/543/545+
SPA-ZC 400
IEC
61850-8-1
REX 521+
SPA-ZC 402
IEC
61850-8-1P
ow
er
SPA
CET for SPA-ZC 40x
SCLSCL
SCL
Connectivity Packages
1
CAP 505 *.AR filefor REx 541/543/545
2
SCLfile
3
SCLfile
4
Communication
© F
ISU
B 6
5/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Distribution Automation – Content
Introduction & overview of Distribution Automation
Product range Protection relays & terminals
Simulator
Communication
Commitment to new standard IEC61850
Training, Support & Service
© F
ISU
B 6
6/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
A new standard for open communication
A new communication and engineering standard for substation automation
Higher interoperability between devices, tools and systems from different vendors
We are committed to IEC 61850
All new ABB distribution IEDs will have an embedded IEC 61850 support
IEC 61850
”Where has been life – there has been communication”
© F
ISU
B 6
7/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Distribution Automation – Content
Introduction & overview of Distribution Automation
Product range
Protection relays & terminals
Simulator
Communication
Commitment to new standard IEC61850
Training, Service and Support
© F
ISU
B 6
8/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Vaasa University
22
hhhhh
Training, Service and Support
© F
ISU
B 6
9/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Product Training
Standard and tailor-made training courses for Distribution Automation products
Designed for Engineers and Users of protection and control products Medium voltage protection applications Relays and terminals Substation communication
Well-structured training materials and methods Theory and presentations Hands-on exercises and simulations
Scope of training services Training and exercises at ABB or at customer’s
premises
Training, Service and Support
© F
ISU
B 7
0/ 2
2M
icro
SC
AD
A P
artn
ers
Clu
b.pp
t 02.
04.2
007
Technical Support
Well structured local and global technical support local experts support local customers on-site / off-site global specialists (factory) support the local experts
Technical guides, documentation and product information available online on the web:
http://www.abb.com/substationautomation
Customer / OEM
local field engineer
local or regional experts global factory specialist
Training, Service and Support