Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3 Temperature Rise Insulation Class Frequency 60Hz DESCRIPTION Type DRY TYPE DISTRIBUTION (ANN) Weight (LBS/KG) MODEL: MT 3A1-P TECHNICAL DATA MARCUS 3-PHASE ISOLATING Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: [email protected] PERFORMANCE No load loss Total loss Noise level EFFICIENCY Efficiency = 94.0% Primary connectors per phase : #14-#4 Secondary connectors per phase: #14-#4 PHYSICAL DIMENSIONS MOUNTING: WALL Customer / PO COMMENTS Project Engineer Revision Date Connection Impedance Contractor BIL. FEATURES: - Anti-vibration pads installed between the core/coil and the enclosure - Ground lug provided - Leads brought-up and solidly positioned into separate terminal boards - CSA enclosure: ventilated painted ASA 61gray - Copper windings - Copper ground strap between core/coil and enclosure 11" 11" 11 1 2 " 11" FRONT VIEW SIDE VIEW 3 8 1 4 " 9 1 2 " 600 208Y / 120 & & 55 / 25 (%z) - CSA certified / UL listed 5.1 Dyn1(TT-1) 10KV 180W 24W 45dB .26 1" 14 1 2 "

Upload: vodat

Post on 05-Dec-2018

235 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

Enclosure Drip shield

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight (LBS/KG)

MODEL: MT 3A1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 94.0%

Primary connectors per phase : #14-#4

Secondary connectors per phase: #14-#4

PHYSICAL DIMENSIONS

MOUNTING: WALL

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- CSA enclosure: ventilated painted ASA 61gray

- Copper windings

- Copper ground strap between core/coil and enclosure

11"

11"

11

1

2

"

11"

FRONT VIEW

SIDE VIEW

3

8

1

4

"

9

1

2

"

600

208Y / 120

220°C

150°C

55 / 25

(%z)

- CSA certified / UL listed

5.1

Dyn1(TT-1)

10KV

180W

24W

45dB

K.O.'S Ø1"

1"

14

1

2

"

Page 2: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

Enclosure Drip shield

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight (LBS/KG)

MODEL: MT 3B1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 94.0%

Primary connectors per phase : #14-#4

Secondary connectors per phase: #14-#4

PHYSICAL DIMENSIONS

MOUNTING: WALL

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- CSA enclosure: ventilated painted ASA 61gray

- Copper windings

- Copper ground strap between core/coil and enclosure

11"

11"

11

1

2

"

11"

FRONT VIEW

SIDE VIEW

3

8

1

4

"

9

1

2

"

480

208Y / 120

220°C

150°C

55 / 25

(%z)

- CSA certified / UL listed

5.1

Dyn1(TT-1)

10KV

180W

24W

45dB

K.O.'S Ø1"

1"

14

1

2

"

Page 3: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

MARCUS

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

13

1

16

"

21"18

3

16

" 18"

13

3

16

"

21"

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight (LBS/KG)

MODEL: MT 6A1-PTECHNICAL DATA

3-PHASE ISOLATING

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

PHYSICAL DIMENSIONS

MOUNTING: WALL

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Impedance

Contractor

BIL.

6

10

1

2

"

19

1

4

"

FRONT VIEW SIDE VIEW

600

208Y / 120

220°C

150°C

85 / 39

Connection

(%z)

10KV

5.5

16

11

16

"

MOUNTING HOLE

Ø

3

4

"(TYP)

Ø1"(TYP)

10

1

2

"

5

1

4

"

3

8

"

3

8

"

Dyn1(TT-1)

335W

35W

45dB

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

- Copper windings

Primary connectors per phase : #14-#4

Secondary connectors per phase: #14-#4

Efficiency = 94.1%

Page 4: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

MARCUS

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

13

1

16

"

21"18

3

16

" 18"

13

3

16

"

21"

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight (LBS/KG)

MODEL: MT 6B1-PTECHNICAL DATA

3-PHASE ISOLATING

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

PHYSICAL DIMENSIONS

MOUNTING: WALL

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Impedance

Contractor

BIL.

6

10

1

2

"

19

1

4

"

FRONT VIEW SIDE VIEW

480

208Y / 120

220°C

150°C

85 / 39

Connection

(%z)

10KV

5.5

16

11

16

"

MOUNTING HOLE

Ø

3

4

"(TYP)

Ø1"(TYP)

10

1

2

"

5

1

4

"

3

8

"

3

8

"

Dyn1(TT-1)

335W

35W

45dB

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

- Copper windings

Primary connectors per phase : #14-#4

Secondary connectors per phase: #14-#4

Efficiency = 94.1%

Page 5: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

13

1

16

"

21"18

3

16

" 18"

13

3

16

"

21"

10

1

2

"

19

1

4

"

FRONT VIEW SIDE VIEW

16

11

16

"

MOUNTING HOLE

Ø

3

4

(TYP)

Ø1"(TYP)

10

1

2

"

5

1

4

"

3

8

"

3

8

"

MARCUS

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight (LBS/KG)

MODEL: MT 10A1-PTECHNICAL DATA

3-PHASE ISOLATING

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 94.8%

Primary connectors per phase : #14-#4

Secondary connectors per phase: #14-#4

PHYSICAL DIMENSIONS

MOUNTING: WALL

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Impedance

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

10

600

208Y / 120

220°C

150°C

110 / 50

Connection

(%z)

10KV

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

- Copper windings

5.6

Dyn1(TT-1)

520W

42W

45dB

Page 6: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

13

1

16

"

21"18

3

16

" 18"

13

3

16

"

21"

10

1

2

"

19

1

4

"

FRONT VIEW SIDE VIEW

16

11

16

"

MOUNTING HOLE

Ø

3

4

(TYP)

Ø1"(TYP)

10

1

2

"

5

1

4

"

3

8

"

3

8

"

MARCUS

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight (LBS/KG)

MODEL: MT 10B1-PTECHNICAL DATA

3-PHASE ISOLATING

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 94.8%

Primary connectors per phase : #14-#4

Secondary connectors per phase: #14-#4

PHYSICAL DIMENSIONS

MOUNTING: WALL

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Impedance

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

10

480

208Y / 120

220°C

150°C

110 / 50

Connection

(%z)

10KV

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

- Copper windings

5.6

Dyn1(TT-1)

520W

42W

45dB

Page 7: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

13

1

16

"

21"18

3

16

" 18"

13

3

16

"

21"

10

1

2

"

19

1

4

"

FRONT VIEW SIDE VIEW

16

11

16

"

MOUNTING HOLE

Ø

3

4

(TYP)

Ø1"

10

1

2

"

5

1

4

"

3

8

"

5

1

4

"

MARCUS

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight (LBS/KG)

MODEL: MT 15A1-PTECHNICAL DATA

3-PHASE ISOLATING

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 97.48%

NEMA TP-1)

Primary connectors per phase : #14-#4

Secondary connectors per phase: #8-2/0

PHYSICAL DIMENSIONS

MOUNTING: WALL

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Impedance

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

15

600

208Y / 120

220°C

150°C

170 / 78

Connection

(%z)

10KV

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

5.3

Dyn1(TT-1)

- Copper windings

861W

55W

45dB

Page 8: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

13

1

16

"

21"18

3

16

" 18"

13

3

16

"

21"

10

1

2

"

19

1

4

"

FRONT VIEW SIDE VIEW

16

11

16

"

MOUNTING HOLE

Ø

3

4

(TYP)

Ø1"

10

1

2

"

5

1

4

"

3

8

"

5

1

4

"

MARCUS

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight (LBS/KG)

MODEL: MT 15B1-PTECHNICAL DATA

3-PHASE ISOLATING

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 97.48%

NEMA TP-1)

Primary connectors per phase : #14-#4

Secondary connectors per phase: #8-2/0

PHYSICAL DIMENSIONS

MOUNTING: WALL

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Impedance

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

15

480

208Y / 120

220°C

150°C

170 / 78

Connection

(%z)

10KV

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

5.3

Dyn1(TT-1)

- Copper windings

861W

55W

45dB

Page 9: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

22

1

2

"

14

1

4

"

12

3

4

"

21"

22

1

2

"

18

3

4

"

FRONT VIEW SIDE VIEW

MOUNTING HOLE

Ø

3

4

"(TYP)

Ø1"

17

3

4

"

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 30A1TECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure NEMA 2

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Primary connectors per phase : #14-#4

Secondary connectors per phase: #8-2/0

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

30

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

600

208Y / 120

220°C

(LBS/KG) 250 / 140

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

5.1

Open Delta auto

10KV

1250W

106W

45dB

- Copper windings

1

1

8

"

3

4

"1

1

8

"

3

4

"

Efficiency = 97.56%

( As per CSA C802.2 &

NEMA TP-1)

Page 10: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

22

1

2

"

14

1

4

"

12

3

4

"

21"

22

1

2

"

18

3

4

"

FRONT VIEW SIDE VIEW

MOUNTING HOLE

Ø

3

4

"(TYP)

Ø1"

17

3

4

"

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 30B1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 97.56%

NEMA TP-1)

Primary connectors per phase : #14-#4

Secondary connectors per phase: #8-2/0

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

30

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

480

208Y / 120

220°C

(LBS/KG)250 / 140

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

5.1

Dyn1(TT-1)

10KV

1664W

106W

45dB

- Copper windings

1

1

8

"

3

4

"1

1

8

"

3

4

"

Page 11: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

FRONT VIEWSIDE VIEW

25

1

2

"

27"

16

3

8

"

23"15

3

8

"

MOUNTING HOLE

Ø

3

4

"(TYP)

Ø1"

19

7

8

"

1

1

4

"

1

2

"

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 45A1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 97.98%

NEMA TP-1)

Primary connectors per phase : #14-#4

Secondary connectors per phase: #6-250MCM

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

45

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

600

208Y / 120

220°C

(LBS/KG) 370 / 169

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

4.8

Dyn1(TT-1)

10KV

2000W

137W

45dB

- Copper windings

Page 12: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

FRONT VIEWSIDE VIEW

25

1

2

"

27"

16

3

8

"

23"15

3

8

"

MOUNTING HOLE

Ø

3

4

"(TYP)

Ø1"

19

7

8

"

1

1

4

"

1

2

"

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 45B1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 97.98%

NEMA TP-1)

Primary connectors per phase : #14-#4

Secondary connectors per phase: #6-250MCM

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

45

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

480

208Y / 120

220°C

(LBS/KG) 370 / 169

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

4.8

Dyn1(TT-1)

10KV

2000W

137W

45dB

- Copper windings

Page 13: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

FRONT VIEWSIDE VIEW

25

1

2

"

27"

16

3

8

"

23"15

3

8

"

MOUNTING HOLE

Ø

3

4

"(TYP)

Ø1"

19

7

8

"

1

1

4

"

1

2

"

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 50A1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 97.98%

NEMA TP-1)

Primary connectors per phase : #14-#4

Secondary connectors per phase: #6-250MCM

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

50

PHYSICAL DIMENSIONS

MOUNTING: WALL / FLOOR

600

208Y / 120

220°C

(LBS/KG)425 / 193

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

4.8

Dyn1(TT-1)

10KV

2080W

45dB

137W

- Copper windings

Page 14: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

FRONT VIEWSIDE VIEW

25

1

2

"

27"

16

3

8

"

23"15

3

8

"

MOUNTING HOLE

Ø

3

4

"(TYP)

Ø1"

19

7

8

"

1

1

4

"

1

2

"

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 50B1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 97.98%

NEMA TP-1)

Primary connectors per phase : #14-#4

Secondary connectors per phase: #6-250MCM

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

50

PHYSICAL DIMENSIONS

MOUNTING: WALL / FLOOR

480

208Y / 120

220°C

(LBS/KG)425 / 193

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

4.8

Dyn1(TT-1)

10KV

2080W

45dB

137W

- Copper windings

Page 15: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

FRONT VIEW SIDE VIEW

25

1

2

"

27"

16

3

8

"

23"15

3

8

"

MOUNTING HOLE Ø

3

4

"(TYP)

Ø1"

19

7

8

"

1

1

4

"

1

2

"

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 75A1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 98.27%

NEMA TP-1)

Primary connectors per phase : #6-2/0

Secondary connectors per phase: #6-250MCM

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

75

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

600

208Y / 120

220°C

(LBS/KG)520 / 237

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

- Copper windings

4.7

Dyn1(TT-1)

10KV

2800W

50dB

200W

Page 16: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

FRONT VIEW SIDE VIEW

25

1

2

"

27"

16

3

8

"

23"15

3

8

"

MOUNTING HOLE Ø

3

4

"(TYP)

Ø1"

19

7

8

"

1

1

4

"

1

2

"

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 75B1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 98.27%

NEMA TP-1)

Primary connectors per phase : #6-2/0

Secondary connectors per phase: #6-250MCM

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

75

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

480

208Y / 120

220°C

(LBS/KG)520 / 237

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

- Copper windings

4.7

Dyn1(TT-1)

10KV

2800W

50dB

200W

Page 17: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

FRONT VIEW SIDE VIEW

30

3

8

"

20"

36

1

4

"

27

1

2

" 15

5

8

"

MOUNTING HOLE

Ø

3

4

"(TYP)

23

1

2

"

1

3

8

"2"

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 112.5A1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 98.35%

NEMA TP-1)

Primary connectors per phase : #8-250MCM

Secondary connectors per phase: #2/0-600MCM

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

112.5

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

600

208Y / 120

220°C

(LBS/KG)820 / 375

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

3.8

Dyn1(TT-1)

10KV

- Copper windings

3438W

350W

50dB

1

3

8

"2"

Page 18: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

FRONT VIEW SIDE VIEW

30

3

8

"

20"

36

1

4

"

27

1

2

" 15

5

8

"

MOUNTING HOLE

Ø

3

4

"(TYP)

23

1

2

"

1

3

8

"2"

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 112.5B1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 98.35%

NEMA TP-1)

Primary connectors per phase : #8-250MCM

Secondary connectors per phase: #2/0-600MCM

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

112.5

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

480

208Y / 120

220°C

(LBS/KG)820 / 375

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

3.8

Dyn1(TT-1)

10KV

- Copper windings

3438W

350W

50dB

1

3

8

"2"

Page 19: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 150A1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 98.53%

NEMA TP-1)

Primary connectors per phase : #4-250MCM

Secondary connectors per phase: #2/0-350MCM(D)

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

150

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

600

208Y / 120

220°C

(LBS/KG) 995 / 451

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

4.0

Dyn1(TT-1)

10KV

4042W

422W

50dB

- Copper windings

FRONT VIEW SIDE VIEW

30

3

8

"

20"

36

1

4

"

27

1

2

" 15

5

8

"

MOUNTING HOLE

Ø

3

4

"(TYP)

23

1

2

"

1

3

8

"2"

1

3

8

"2"

Page 20: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

FRONT VIEW SIDE VIEW

35" 24

1

2

"

46

3

4

"

28"

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 225A1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 98.55%

NEMA TP-1)

Primary connectors per phase : 2/0-350MCM

Secondary connectors per phase: 4/0-600MCM(D)

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

225

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

600

208Y / 120

220°C

(LBS/KG)1450 / 658

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

33"21

1

4

"

4.1

Dyn1(TT-1)

10KV

6058W

610W

55dB

- Copper windings

7

8

"

7

8

"

1

1

2

" 1

1

2

"

MOUNTING HOLE Ø

3

4

"

Page 21: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 150B1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 98.53%

NEMA TP-1)

Primary connectors per phase : #4-250MCM

Secondary connectors per phase: #2/0-350MCM(D)

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

150

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

480

208Y / 120

220°C

(LBS/KG) 995 / 451

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

4.0

Dyn1(TT-1)

10KV

4042W

422W

50dB

- Copper windings

FRONT VIEW SIDE VIEW

30

3

8

"

20"

36

1

4

"

27

1

2

" 15

5

8

"

MOUNTING HOLE

Ø

3

4

"(TYP)

23

1

2

"

1

3

8

"2"

1

3

8

"2"

Page 22: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

FRONT VIEW SIDE VIEW

35" 24

1

2

"

46

3

4

"

28"

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 225B1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 98.55%

NEMA TP-1)

Primary connectors per phase : 2/0-350MCM

Secondary connectors per phase: 4/0-600MCM(D)

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

225

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

480

208Y / 120

220°C

(LBS/KG)1450 / 658

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

33"21

1

4

"

4.1

Dyn1(TT-1)

10KV

6058W

610W

55dB

- Copper windings

7

8

"

7

8

"

1

1

2

" 1

1

2

"

MOUNTING HOLE Ø

3

4

"

Page 23: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 300A1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 98.6%

NEMA TP-1)

Primary connectors per phase : 4/0-350MCM(S)

Secondary connectors per phase: 4/0-750MCM(D)

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

300

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

600

208Y / 120

220°C

(LBS/KG)1810 / 821

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

4.0

Dyn1(TT-1)

10KV

- Copper windings

7790W

790W

55dB

FRONT VIEW SIDE VIEW

35" 24

1

2

"

46

3

4

"

28"

33"21

1

4

"

7

8

"

7

8

"

1

1

2

" 1

1

2

"

MOUNTING HOLE Ø

3

4

"

Page 24: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 300B1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 98.6%

NEMA TP-1)

Primary connectors per phase : 4/0-350MCM(S)

Secondary connectors per phase: 4/0-750MCM(D)

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

300

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

480

208Y / 120

220°C

(LBS/KG)1810 / 821

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

4.0

Dyn1(TT-1)

10KV

- Copper windings

7790W

790W

55dB

FRONT VIEW SIDE VIEW

35" 24

1

2

"

46

3

4

"

28"

33"21

1

4

"

7

8

"

7

8

"

1

1

2

" 1

1

2

"

MOUNTING HOLE Ø

3

4

"

Page 25: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

FRONT VIEWSIDE VIEW

MOUNTING HOLE

Ø

3

4

"(TYP)

36

1

2

"30

3

4

"

51

5

8

"

34

1

4

"30

1

4

"

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 450A1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 98.68%

NEMA TP-1)

Primary connectors per phase : N/A

Secondary connectors per phase: N/A

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

450

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

600

208Y / 120

220°C

(LBS/KG)2550 / 1157

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

- Copper windings

Dyn1(TT-1)

10KV

4.3

10,100W

1100W

55dB

1"1"

1

8

"

1

8

"

36"

Page 26: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

FRONT VIEWSIDE VIEW

MOUNTING HOLE

Ø

3

4

"(TYP)

36

1

2

"30

3

4

"

51

5

8

"

34

1

4

"30

1

4

"

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 450B1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 98.68%

NEMA TP-1)

Primary connectors per phase : N/A

Secondary connectors per phase: N/A

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

450

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

480

208Y / 120

220°C

(LBS/KG)2550 / 1157

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

- Copper windings

Dyn1(TT-1)

10KV

4.3

10,100W

1100W

55dB

1"1"

1

8

"

1

8

"

36"

Page 27: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 500A1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 98.69%

NEMA TP-1)

Primary connectors per phase : N/A

Secondary connectors per phase: N/A

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

500

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

600

208Y / 120

220°C

(LBS/KG)2760 / 1252

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

- Copper windings

Dyn1(TT-1)

10KV

4.1

10,220W

1200W

55dB

FRONT VIEWSIDE VIEW

MOUNTING HOLE

Ø

3

4

"(TYP)

36

1

2

"30

3

4

"

51

5

8

"

34

1

4

"30

1

4

"

1"1"

1

8

"

1

8

"

36"

Page 28: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 500B1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 98.69%

NEMA TP-1)

Primary connectors per phase : N/A

Secondary connectors per phase: N/A

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

500

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

480

208Y / 120

220°C

(LBS/KG)2760 / 1252

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

- Copper windings

Dyn1(TT-1)

10KV

4.1

10,220W

1200W

55dB

FRONT VIEWSIDE VIEW

MOUNTING HOLE

Ø

3

4

"(TYP)

36

1

2

"30

3

4

"

51

5

8

"

34

1

4

"30

1

4

"

1"1"

1

8

"

1

8

"

36"

Page 29: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 600A1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 98.8%

NEMA TP-1)

Primary connectors per phase : N/A

Secondary connectors per phase: N/A

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

600

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

600

208Y / 120

220°C

(LBS/KG)3150 / 1429

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

- Copper windings

4.1

Dyn1(TT-1)

10KV

10,300W

1280W

55dB

FRONT VIEWSIDE VIEW

MOUNTING HOLE

Ø

3

4

"(TYP)

36

1

2

"30

3

4

"

51

5

8

"

34

1

4

"30

1

4

"

1"1"

1

8

"

1

8

"

36

Page 30: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3

KVA

Primary (Volts)

Secondary (Volts)

Phase 3

Temperature Rise

Insulation Class

Frequency 60Hz

DESCRIPTION

Type DRY TYPE DISTRIBUTION (ANN)

Weight

MODEL:MT 600B1-PTECHNICAL DATA

MARCUS

3-PHASE ISOLATING

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Enclosure Drip shield

PERFORMANCE

No load loss

Total loss

Noise level

EFFICIENCY

Efficiency = 98.8%

NEMA TP-1)

Primary connectors per phase : N/A

Secondary connectors per phase: N/A

Customer / PO

COMMENTS

Project

Engineer

Revision Date

Connection

Impedance (%z)

Contractor

BIL.

FEATURES:

- Anti-vibration pads installed between the core/coil and

the enclosure

- Ground lug provided

- Leads brought-up and solidly positioned into separate

terminal boards

- Transformer meets the efficiency values as per CSA

C802.2 / NEMA TP-1

(As per CSA C802.2 &

600

PHYSICAL DIMENSIONS

MOUNTING: FLOOR

480

208Y / 120

220°C

(LBS/KG)3150 / 1429

150°C

- CSA enclosure: ventilated painted ASA 61gray

- Copper ground strap between core/coil and enclosure

- CSA certified / UL listed

- Copper windings

4.1

Dyn1(TT-1)

10KV

10,300W

1280W

55dB