GRUNDFOS DATA BOOKLET TPE2 50-240-N-A-F-A-BQQE Grundfos pump 98437897 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/TPE00/98437897/TPE2-50-240-N-A-F-A-BQQE.html [email protected] tel. +31 152 610 900 fax. +31 152 616 289 BE > THINK > INNOVATE

Upload: others

Post on 01-Apr-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump

GRUNDFOS DATA BOOKLET

TPE2 50-240-N-A-F-A-BQQE Grundfos pump 98437897

Thank you for your interest in our products. Please contact us for more information, or visit our website

https://www.lenntech.com/grundfos/TPE00/98437897/TPE2-50-240-N-A-F-A-BQQE.html

[email protected]. +31 152 610 900 fax. +31 152 616 289

BE > THINK > INNOVATE

Page 2: Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump

Printed from Grundfos Product Centre [2018.06.003]

Position Qty. Description1 TPE2 50-240-N A-F-A-BQQE

Product No.: On request

Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter.The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can beremoved for maintenance or service while the pump housing remains in the pipework.The shaft seal is according to EN 12756. Pipework connection is via PN 6/10 DIN flanges (EN 1092-2and ISO 7005-2).The pump is fitted with a fan-cooled, permanent-magnet synchronous motor. The motor efficiency isclassified as IE5 in accordance with IEC 60034-30-2.The motor includes a frequency converter and PI controller in the motor terminal box. This enablescontinuously variable control of the motor speed, which again enables adaptation of the performance toa given requirement.

Further product detailsAn operating panel on the motor terminal box enables setting of required setpoint as well as setting ofpump to "Min." or "Max." operation or to "Stop". The Grundfos Eye indicator on the operating panelprovides visual indication of pump status:

• "Power on": Motor is running (rotating green indicator lights) or not running (permanently greenindicator lights)

• "Warning": Motor is still running (rotating yellow indicator lights) or has stopped (permanentlyyellow indicator lights)

• "Alarm": Motor has stopped (flashing red indicator lights).

Communication with the pump is possible by means of Grundfos GO Remote (accessory). The remotecontrol enables further settings as well as reading out of a number of parameters such as "Actualvalue", "Speed", "Power input" and total "Power consumption".

The product's minimum efficiency index (MEI) is greater or equal to 0.70. This is by the CommissionRegulation (EU) considered as an indicative benchmark for best-performing water pump available onthe market as from 1 January 2013.

PumpPump housing and pump head are electrocoated to improve the corrosion resistance.Electrocoating includes:1) Alkaline-based cleaning.2) Pretreatment with zinc phosphate coating.3) Cathodic electrocoating (epoxy).4) Curing of paint film at 200-250 °C.

1: Pump housing2: Impeller3: Neck ring4: Pump head/motor stool5: Stub shaft

1/12

Page 3: Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump

Printed from Grundfos Product Centre [2018.06.003]

Position Qty. DescriptionTWINPUMP=D}The twin-head pump is designed with two parallel power-heads. A flap valve in thecommon discharge port is opened by the flow of the pumped liquid and prevents backflow of liquid intothe idle pump head.The pump housing is provided with a replaceable stainles steel/PTFE neck ring to reduce the amount ofliquid running from the discharge side of the impeller to the suction side. The impeller is secured to theshaft with a nut.

The pump is fitted with an unbalanced rubber bellows seal with torque transmission across the springand around the bellows. Due to the bellows, the seal does not wear the shaft, and the axial movementis not prevented by deposits on the shaft.Primary seal:

• Rotating seal ring material: silicon carbide (SiC)• Stationary seat material: silicon carbide (SiC)

This material pairing is used where higher corrosion resistance is required. The high hardness of thismaterial pairing offers good resistance against abrasive particles.Secondary seal material: EPDM (ethylene-propylene rubber)EPDM has excellent resistance to hot water. EPDM is not suitable for mineral oils.

The motor stool forms connection between the pump housing and the motor, and is equipped with amanual air vent screw for venting of the pump housing and the shaft seal chamber. The sealingbetween motor stool and pump housing is an O-ring.The central part of the motor stool is provided with guards for protection against the shaft and coupling.The pump shaft is fastened directly on the motor shaft with key and set screws.

MotorThe motor is a totally enclosed, fan-cooled motor with principal dimensions to IEC and DIN standards.Electrical tolerances comply with IEC 60034.

The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.The motor requires no external motor protection. The motor control unit incorporates protection againstslow- and quick-rising temperatures, e.g. constant overload and stalled conditions.

The terminal box holds terminals for these connections:• one dedicated digital input• two analog inputs, 0(4)-20 mA, 0-5 V, 0-10 V, 0.5 - 3.5 V• 5 V voltage supply to potentiometer and sensor• one configurable digital input or open-collector output• Grundfos Digital Sensor input and output• 24 V voltage supply for sensors• two signal-relay outputs (potential-free contacts)• GENIbus connection• interface for Grundfos CIM fieldbus module.

Technical data

Controls:Frequency converter: Built-in

Liquid:Pumped liquid: WaterLiquid temperature range: -25 .. 120 °CLiquid temperature during operation: 20 °CDensity: 998.2 kg/m³

Technical:Rated flow: 33.1 m³/hRated head: 19.6 mActual impeller diameter: 74 mmPrimary shaft seal: BQQECurve tolerance: ISO9906:2012 3B

Materials:Pump housing: Cast iron

EN-JL1040

2/12

Page 4: Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump

Printed from Grundfos Product Centre [2018.06.003]

Position Qty. DescriptionASTM A48-40 B

Impeller: Composite PES/PP 30% GF

Installation:Range of ambient temperature: -20 .. 50 °CMaximum operating pressure: 10 barFlange standard: DINPipe connection: DN 50Pressure rating: PN 6/10(@): 280 mmFlange size for motor: 56C

Electrical data:Motor type: 90LCIE Efficiency class: IE5Rated power - P2: 2.2 kWMains frequency: 50 HzRated voltage: 3 x 380-500 VRated current: 4.35-3.55 ACos phi - power factor: 0.91-0.85Rated speed: 480-5900 rpmEfficiency: 90.1%Motor efficiency at full load: 90.1 %Enclosure class (IEC 34-5): IP55Insulation class (IEC 85): F

Others:Minimum efficiency index, MEI ≥: 0.7ErP status: EuP Standalone/Prod.Net weight: 29.1 kgGross weight: 36.3 kgShipping volume: 0.1 m³

3/12

Page 5: Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump

Printed from Grundfos Product Centre [2018.06.003]

On request TPE2 50-240-N A-F-A-BQQE 50 HzH

[m]

0

2

4

6

8

10

12

14

16

18

20

22

24

26

Q [m³/h]0 5 10 15 20 25 30 35 40 45 50

eta[%]

0

20

40

60

80

100

TPE2 50-240-N, 3*400 V

100 %

90 %

80 %

70 %

60 %

50 %

40 %

25 %19 %

P[kW]

0.0

0.5

1.0

1.5

2.0

2.5

NPSH[m]

0

10

20

30

40

50P1 (motor+freq.converter)

P2

4/12

Page 6: Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump

Printed from Grundfos Product Centre [2018.06.003]

H[m]

0

2

4

6

8

10

12

14

16

18

20

22

24

26

Q [m³/h]0 10 20 30 40

eta[%]

0

20

40

60

80

100

TPE2 50-240-N, 3*400 V

100 %

90 %

80 %

70 %

60 %

50 %

40 %

25 %19 %

P[kW]

0.0

0.5

1.0

1.5

2.0

2.5

NPSH[m]

0

10

20

30

40

50P1 (motor+freq.converter)

P2

158

158 158

50

75 91 280

165

72

469

162

134

134

122

3

15

8

26

23

25

24

7

B

Y

6

5

2

4

10

A

+24 V*+24 V*

AI2

GDS RX

GDS TX

GND

GENIbus A

GENIbus B

+24 V

GND

GENIbus Y

GND

DI1

AI1

DI3/OC1+24 V*

OC DIGND

NC

C2

NO

NC

C1

NO

+24 V*+24 V* +24 V*/5 V*

L2

L1

L3

PE

L3

L2

L1

+24 V*/5 V*

+5 V*

+5 V

+24 V

+5 V

Description ValueGeneral information:Product name: TPE2 50-240-N A-F-A-BQQEProduct No: On requestEAN number: On requestTechnical:Rated flow: 33.1 m³/hRated head: 19.6 mHead max: 240 dmActual impeller diameter: 74 mmPrimary shaft seal: BQQECurve tolerance: ISO9906:2012 3BPump version: AModel: AMaterials:Pump housing: Cast iron

EN-JL1040ASTM A48-40 B

Impeller: Composite PES/PP 30% GFMaterial code: AInstallation:Range of ambient temperature: -20 .. 50 °CMaximum operating pressure: 10 barFlange standard: DINPipe connection: DN 50Pressure rating: PN 6/10(@) 280 mmFlange size for motor: 56CConnect code: FLiquid:Pumped liquid: WaterLiquid temperature range: -25 .. 120 °C

Liquid temperature duringoperation:

20 °C

Density: 998.2 kg/m³Electrical data:Motor type: 90LCIE Efficiency class: IE5Rated power - P2: 2.2 kWMains frequency: 50 HzRated voltage: 3 x 380-500 VRated current: 4.35-3.55 ACos phi - power factor: 0.91-0.85Rated speed: 480-5900 rpmEfficiency: 90.1%Motor efficiency at full load: 90.1 %Enclosure class (IEC 34-5): IP55Insulation class (IEC 85): FMotor protec: YESMotor No: 99137907Controls:Control panel: HMI200 - StandardFunction Module: FM200 - StandardFrequency converter: Built-inOthers:Minimum efficiency index, MEI ≥: 0.7ErP status: EuP Standalone/Prod.Net weight: 29.1 kgGross weight: 36.3 kgShipping volume: 0.1 m³Config. file no: 98819282

158158158

50

7591280

165

5/12

Page 7: Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump

Printed from Grundfos Product Centre [2018.06.003]

On request TPE2 50-240-N A-F-A-BQQE 50 Hzcos phi

eta

0.0

0.2

0.4

0.6

0.8

P2 [kW]0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1

I[A]

0.0

1.0

2.0

3.0

4.0

TPE250-240-N + 90LC 2.2 kW 3*400 V, 50 Hz

eta

cos phi

I

n[rpm]

0

1000

2000

3000

4000

5000

P1[kW]

0.0

1.0

2.0

3.0

4.0

5.0

n

P1 (motor+freq.converter)

n = 100 %

6/12

Page 8: Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump

Printed from Grundfos Product Centre [2018.06.003]

On request TPE2 50-240-N A-F-A-BQQE 50 Hz

Note! All units are in [mm] unless others are stated.Disclaimer: This simplified dimensional drawing does not show all details.

158

158 158

50

75 91 280

165

72

469

162

134

134

122

7/12

Page 9: Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump

Printed from Grundfos Product Centre [2018.06.003]

Exploded view

301a

219

92

7

7a

77

301a

92

11

9

51

100

49

105

45

215a

215

18

217215a

534a534

531531a

28

17

251d

251a

6

11b

66a

67

530530a

8/12

Page 10: Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump

Printed from Grundfos Product Centre [2018.06.003]

Sectional drawing (TM058200 for TPE2,TPE3)

4

2 13

5

TM058200

9/12

Page 11: Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump

Printed from Grundfos Product Centre [2018.06.003]

Exploded view ( TM057026 for MGE model H/I )

251d

251b

290

287277a

286

277

273a

273

268268a289a289

288b288288a

251a

252b

156c

159d

156b

156d188

275a

153

154

158

178

185

192

191

159e

156c 156

151152

266

187

291

293

252a

172

150

287a

502

273b

157

10/12

Page 12: Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump

Printed from Grundfos Product Centre [2018.06.003]

Parts list TPE2 50-240-N, Product No. On requestValid from 25.12.2012 (1252)

Pos Description Annotation Données de classification Référence Quantité Unité- Motor 1 pcs

Terminal 3Pan head thread forming screw 4

150 Stator housing 1150 Stator 1151 Fan cover 1152 Pan head thread forming screw 6152 Pan head thread forming screw 1152 Pan head thread forming screw 4152 Pan head thread forming screw 1153 Ball bearing 1154 Ball bearing Designation: 6204.2Z.C3.SYN 1156 Fan 1156b Flange 1156d Gasket Internal diameter: 114,80 1

Outer diameter: 121,20Thickness: 0,25

157 O-ring Diameter: 47 1Material type: NBRThickness: 3

158 Waved washer 1159a Seal ring 1159c Seal ring 1166 Torx Screw 2172 Shaft w/rotor 1172a Parallel key 1173a Base 1185 Cross recess Pan head screw 4186 Drain plug 1187 Retaining ring 1188 Retaining ring 1203 Terminal plug 1251a Control box 1251b Control box 1251d Pan head thread forming screw 4266 Connector plug 3-pole 1266 Connector plug 3-pole 1266 Connector plug 8-pole 1266 Connector plug 8-pole 1266 Connector plug 10-pole 1268 Pan head screw 1273 Funct. Module cpl. 1275a Pin 1277 Isolation cover 1277a Cross recess Pan head screw 4277a Cross recess Pan head screw 1277a Cross recess Pan head screw 1286 Spacer 1286 Spacer 1287 Cover 1288 Wire clamp 3288b Washer 6289 Wire clamp 1290 Control panel, cpl. 1300 Plug cpl. 4301 Jumper 1

- Guard 2 pcs7 Guard 17a Pan head screw 2

11/12

Page 13: Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump

Printed from Grundfos Product Centre [2018.06.003]

Pos Description Annotation Données de classification Référence Quantité Unité66 Lock washer 2

- Motor stool cpl. 1 pcs17 Air vent screw 128 Hex head cap screw Length (mm): 25 4

Thread: UNC 3/8"77 Motor stool 1

- Pump housing cpl. 1 pcs6 Pump housing 145 Neck ring cpl. 1

- Shaft cpl. 1 pcs9 Socket set screw 311b Key 151 Shaft 166a Wedge lock washer 167 Lock nut Thread: M8 1

- 49 Impeller cpl. 1 pcsImpeller cpl. 1

100 Spacer ring 1 pcs105 Shaft seal 1 pcs

12/12

Page 14: Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump

Disclaimer: The information about the Grundfos pump in this document may be outdated. Data may be subject to alterations without further notice. Please contact us to verify the data above is still accurate/up-to-date.

All information is copyright Grundfos.

[email protected]://www.lenntech.comtel. +31 152 610 900 fax. +31 152 616 289