1 R CR FFU 潔淨室- 風機濾網機組 TOPWELL 累積30年的潔淨室工程經驗,結合台灣高科技電子產業技術,及傑出的軟體技術人 才,並應用台灣企業優良的加工技術與品質,生產出優於國際品牌的新一代高效率風機濾網機 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU TOPWELL , accumulated 30 years of service in cleanroom construction, developed the new generation of high 節能省電高效率 FFU 機組,整機效率高達56% Total Eff 56% 多種不同特性葉輪的組合應用, 達成高效率低噪音的使用目標。 Aerofoil or centrifugal fan is selected to meet the application requirement. 藉由3D 氣流模擬軟體,研發最佳 氣流場的箱體結構,可降低風道擾 流,提升風機效率,促使風量風佈 均勻。 FFU casing is designed, via air flow simulation software, to ensure the efficiency and flow distribution. 產品經專業研究機構的測試與驗證,確保研發數據的正確性,提升產品的效率及品質。 FFU performance is tested and verified by third party lab or research institute. efficiency Fan Filter Unit, in synergy of Taiwan hi-tech electronic technology and HMI software development, manufactured under the reliable quality in Taiwan. 風扇特性分析 Fan Features 研發與測試 Research and Development 65% of static pressure efficiency 65%高靜壓效率 3D葉片風輪 Aerofoil fan 多翼式葉片風輪 Centrifugal fan

Upload: others

Post on 02-Apr-2022

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

1

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

TOPWELL 累積30年的潔淨室工程經驗,結合台灣高科技電子產業技術,及傑出的軟體技術人

才,並應用台灣企業優良的加工技術與品質,生產出優於國際品牌的新一代高效率風機濾網機

組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU。

TOPWELL , accumulated 30 years of service in cleanroom construction, developed the new generation of high

節能省電高效率 FFU 機組,整機效率高達56% Total Eff 56%

多種不同特性葉輪的組合應用,

達成高效率低噪音的使用目標。

Aerofo i l or centr i fugal fan is selected to meet the application requirement.

藉 由 3 D 氣 流 模 擬 軟 體 , 研 發 最 佳

氣流場的箱體結構,可降低風道擾

流,提升風機效率,促使風量風佈

均勻。

FFU casing is designed, via air flow simulation software, to ensure the efficiency and flow distribution.

產品經專業研究機構的測試與驗證,確保研發數據的正確性,提升產品的效率及品質。

FFU performance is tested and verified by third party lab or research institute.

efficiency Fan Filter Unit, in synergy of Taiwan hi-tech electronic technology and HMI software development, manufactured under the reliable quality in Taiwan.

風扇特性分析Fan Features

研發與測試Research and Development

65% of static pressure efficiency65%高靜壓效率

3D葉片風輪

Aerofoil fan

多翼式葉片風輪

Centrifugal fan

Page 2: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

2

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

AC/DC motor controller

目前 Harmonic 數據的要

求,大多參照 IEEE 的規

範,電壓 380V 以上的為

15% 以下,380V 以下為

18% 以下,topwel l 也是

依據此一規定,全機種的

Harmonic 值均訂在11%

以下的標準。

Refer to IEEE specifications, the harmonic is to be less t han 15% and 18% fo r voltage > 380V and voltage < 380V, respectively. However, TOPWELL FFU controller is able to achieve the higher standard of harmonic less than 11%.

控制機板由國際大廠在台灣投資設

立的專業製造廠商開發生產,產品

符 合 E M C 、 S E M I 相 關 規 範 或 標

準。控制基板內建諧波抑制器,有

效降低用戶端的干擾。

FFU controller is designed by Taiwan professional company, which is invested by international well known company, and is manufactured in Taiwan. The controller is tested to meet the EMC and SEMI standards and the harmonic filter is built-in to minimize the interference of power source.

MIT台灣設計製造的高品質高效率控制基板High efficiency design of FFU controller

Power Factor Correction VS Output Power Curve

AC 208V AC 220V AC 277V 輸出瓦特(W)

Total Harmonic Distortion VS Output Power Curve

輸出瓦特(W)AC 208V AC 220V AC 277V

AC / DC控制基板

DC控制基板

AC控制基板

Total Harmonic Distortion VS Output Power Curve

500.00%

2.00%

4.00%

6.00%TH

D(%

)

8.00%

10.00%

12.00%

14.00%

16.00%

100 150 200 250 300 350 400

THD% / Power Factor Correction CurvePowr Factor Correction VS Output Power Curve

0 50

0.82

0.84

0.86

0.88

0.92

0.94

0.96

0.98

1.02

1.00

0.90

PF

100 150 200 250 300 350 400 450

BLDC motor controller

AC motor controller

Page 3: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

3

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

高 效 率 直 流 無 刷 馬 達 , 機 電 效 率 高 達 9 0 % 以 上 , 軸 心 與 軸 承

處 , 具 抗 電 蝕 ( C u r r e n t B u r n ) 設 計 , 軸 承 設 計 使 用 年 限 可 達

100,000 小時。

The external rotor DC brushless motor is designed to achieve over 90% of efficiency, and the shaft/bearing is prevented from electrical pitting to assure the bearing life of 100,000 hours.

TOPWELL

馬達性能測試比較表

Motor performance comparison

備註:一般直流馬達效率約72~82%

Note: General DC motor efficiency is about 72 ~ 82%

沖模外殼

噪音 Noise震動 Vibration低效率 Lower efficiency

漏磁 Magnetic loss干擾 Interference低效率 Lower efficiency

電力諧波干擾 Poor requirements of THD & PFC軸電壓抑制 Higher haft voltage馬達升溫 Motor temperature rise電壓電流保護設計 Inadequate electrical surge protection

高效率高品質馬達High efficiency motor

鍛造外殼

旋波驅動

潔淨室FFU專用

OTHER

1

2

3

1

2

3

馬達特性分析

Motor Features

300

200

100

TopWellImported motor進口品

Domestic motor一般國產品

0

060

65

70

75

80

0.5 1Torque(Nm)

1200 rpm

Effi

cien

cy(%

)

Pow

er C

onsu

mpt

ion(

W)

1.5 2

Precision forged rotor shell

Sine-wave BLDC

High performance for cleanroom application

Stamping rotor shell

Square-wave BLDC

Applicable for air conditioning FCU

方波驅動

空調FCU挪用

Page 4: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

4

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

軸電壓可導致馬達軸承的損壞Electrical corrosion of motor bearing resulted from abnormal of shaft voltage

一般馬達轉動機械在軸與軸承間,及軸承本體內須有油膜的存在,以利軸的旋轉潤滑,而且此

油膜對於小的軸電壓具有絕緣作用。當軸電壓大至超過油膜絕緣強度時,電流即從轉軸通過軸

承路徑進入外殼導入地位,此時油膜將被破壞,而在軸承及軸的金屬接觸部形成電流流通造成

電弧(arc)作用,電弧的高溫即引起金屬的熔融現象。

While motor rotating, the shaft is rotated against the bearing, and the lubricant is presented in form of oil film in between to facilitate the rotation. In addition to the lubrication, this film shall also have the function of insulation against small shaft voltage. If the shaft voltage is too high (or the insulation is too small), high shaft current is generated across the shaft, via bearing, to motor shell and induced to grounding. The generation of high current will create the electrical arc. The high-temperature of arc may cause the melting of metal contact between shaft and bearing.

異常產品的軸電壓測試顯示

The high shaft voltage occurs in case of abnormal motor

Topwel l 對於軸電壓的設計限制為<3.5V

Topwell motor is designed to limit the shaft voltage to be <3.5V

此熔融現象對於滾動軸承構造,會在軸襯合金處呈現麻點(pit t ing)狀之孔蝕,或在軸上呈現

刮痕狀之損傷,同時電弧作用會導致碳的析出,使潤滑油變黑劣化,受損的金屬表面及碎屑將

造成軸承的異常磨耗加劇,終導致整個軸承損壞或是發生高頻噪音。大部份馬達軸承的設計使

用壽命為100,000小時,但發生此異常狀後,軸承有可能於1 年內就完全損壞。

This melting phenomenon will be presented in form of pitting in the housing of bearing or scratches on the shaft. Due to the electrical corrosion, the lubricant will be blacken and deteriorated from carbon contamination. In combination with the metal injury, it will eventually lead to the generation of noise and bearing damage. Most of the service life of motor bearings is designed of 100,000 hours, but the service life could be drastically reduced to be less than a year due to the electrical corrosion.

Page 5: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

5

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

可將CAD圖面直接轉為圖控劃面

中文INTOUCH 圖控軟體,與廠務監控系統整合容易

INTOUCH software applicable for the monitoring and control system, enable the integration to FMS.

主要控制功能Monitoring and control function

單機控制 Indiv idual control

群組迴路控制 Group control

控制中心集體控制 Control Centre by Server

現場直接控制 Local Control by Local Cl ients

遠端連線控制 Remote Control by Internet

跨平台整合能力 OPC service

工控系統直接整合 HMI ex: Intouch, IFIX

多機群控顯示,點擊圖示單元可顯示單機運轉資料

單機運轉資料顯示

圖控系統的軟體編輯及試機調整,Topwel l 100% 完全自主處理,可於24小時內完成業主的變更需求。

Individual control mode

Group control mode

Display is easily converted from CAD drawing

Test ing, commissioning and maintenance service fu l ly local supported.

Page 6: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

6

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

FFU監控系統架構FFU System

上層監控端

可透過 ETHERNET 網路使用套裝圖控軟體,例如: INTOUCH IFIX、CIMPLICITY 等市面常用軟體,

或自行開發之監控軟體,亦可以整合至既有的廠務系統內。

可以透過 RS-232C 對 TOPWELL 之通訊轉換器讀出寫入。

可以直接對 FFU 控制器讀出寫入。

1

2

3

資料收集器會主動將下層FFU控制器的資訊收集

Type 1

特殊規格,適用整合其他

監控I/O用途。

標準規格,FFU監控系

統專用。

DC FFU控制器 - 網路型 AC FFU控制器 - 網路型 AC FFU控制器 - 非網路型DC FFU控制器 - 網路型

中層資料收集端

Type 2

下層FUU控制器

LD01 WD01 LA01 LA02

註:本系統之FFU控制器為監控通訊版,另有非監控版控制器提供單機手動調速及警報乾接點功能

各類廠務系統 ( 虛線部分為客戶選項 )

通訊轉換器(GATEWAY)

AC、DC並行控制系統

Note:For AC FFU, the non-communication type, which is equipped only with manual control and alarm dry contact, is also available.

上層 (Top level)

中層 (Middle level)

下層 (Bottom level)

PLC for other facility system

Both AC and DC FFU can be integrated.

Top level: HMI

Via ETHERNET, the HMI (INTOUCH, IFIX,CIMPLICITY or self-developed software) Monitors and controls FFUs through gateway.

Direct communication with Topwell gateway by RS-232 is feasible.

Direct communication with Topwell FFU by RS-485 is feasible.

Gathering data from FFU controller actively.

Special request, applicable for other I/O integration.

Standard application for FFU system.

Middle level: Active gateway

Bottom level: FFU controller

DC FFU control ler (M/C) DC FFU control ler (M/C) w/ on-board display AC FFU control ler (M/C) AC FFU control ler (non-M/C)

Max. connection 94,500 FFUs !

Page 7: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

7

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

FFU靜壓值與潔淨室系統壓損的運作關係FFU static pressure selection in consideration CR system requirement.

錯誤觀念:

一 般 F F U 製 造 工 廠 僅 將 F F U 裝 上 H E P A 後 , 即 於 開 放 空 間 測 量 風 量 及 耗 電 數 據 , 實 際 上 此 時

FFU的壓損僅約100~150Pa(僅HEPA的阻抗),遠低於潔淨室實際的壓損阻抗值170~220Pa

( 詳 圖 ) , 故 測 量 的 風 量 及 耗 電 數 據 雖 可 達 到 規 範 數 值 , 但 實 際 裝 置 在 潔 淨 室 後 , 將 因 高 架 地

板 、 冷 卻 盤 管 、 風 道 、 管 線 等 阻 抗 的 增 加 , 使 得 F F U 的 性 能 降 低 而 無 法 滿 足 潔 淨 室 的 要 求 條

件。

Misleading informat ion:

The FFU s ta t i c p ressure se lec t ion sha l l cons ider the CR sys tem s ta t i c p ressure loss inc lud ing ra ised f loor, coo l ing co i l , g r i l le , shaf t space, p ip ing /duct ing space and add i t iona l p ressure fo r fu ture f i l te r dus t accumula t ion , wh ich is ranged f rom 170Pa to 220Pa (see drawing be low) . However, most o f FFU des ign f rom o ther manufacturers only considers the f i l ter pressure loss(100-150Pa), which is far less than actual CR requirement and resul ts in insuff ic ient a i r f low.

RAP=-40Pa

RAP=-45Pa

RAP=9Pa

CR=25Pa

Pre Filter

Waffle floor

DCC

HEPA

汙損

dp=40pa

dp=5pa

dp=100pa dp=150pa

Dust accumulation

dp=12pa

dp=9pa

dp=4pa

Ceiling

Floor

PROCESS EXHAUST

SMOKE EXHAUST

SMOKE EXHAUST FAN

MUA

HEPA潔淨運轉初期FFU:170Pa

Initial static pressure:180Pa

Final static pressure:230Pa

HEPA汙損運轉末期FFU:220Pa

Page 8: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

8

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

ex. AC FFU 1000台

年省電費:NT2,904,924 元 (2,905元/年.台)

ex. DC FFU 1000台(56/47%η)

年節約電能328,320 -度 (Kw.hr)

年省電費:NT935,484 元 (935.5元/年.台)

56%η

47%η

OTHER TOPWELL箱體氣流場設計

高效率馬達

高效率風機

ex. AC FFU 1000台(41/30%η)

年節約電能432,000 -度 (Kw.hr)

年省電費:NT1,230,900 元 (1,231元/年.台)

41%η

30%η

不是全部AC FFU都一樣

OTHER TOPWELL箱體氣流場設計

高效率馬達

高效率風機

OTHER AC 30%η TOPWELL DC 56%

η

別再當冤大頭了!

對!FFU的採購重點是:機組的效率。

唉!殺了老半天,還抵不上一年的電價差。

不是全部DC FFU都一樣

Annual energy saving: 1,019 Kw-hr per unit

Annual energy saving: 432 Kw-hr per unit

Annual energy saving: 328 Kw-hr per unit

Smart Buy!

Sufficient static pressure and efficiency is all that matters!

Less initial cost saving might be not worthy of annual running cost saving!

Same AC FFU ?

Same DC FFU ?

Aerodynamic

High efficiency motor

High efficiency impeller

Aerodynamic

High efficiency motor

High efficiency impeller

Page 9: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

9

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

AC FFU 1200x600 Performance Curves

Speed (H,M,L) H M L

Air Velocity (m/s) 0.35 0.35 0.35

Air Volume (CMM) 15 15 15

Fan static pressure (mmAq)(unit without filter, with inlet guard) 24 22 20

Voltage (V) 220 220 220

Current (A) 0.67 0.64 0.61

Input power (W) 148 141 135

Efficiency(%) 40 38 36

Sound pressure level(dB/LpA1.5) @ H speed 51(with filter, A-weighted)

Noise criterion curve (NC) @ H speed NC-45

Octave frequency(Hz) @ H speed 63 125 250 500 1K 2K 4K 8K

Sound pressure leve(dB) @ H speed 33 44 51 40 37 42 33 29

運轉點 (Duty Point)

0

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

170

180

190

200

Ps(

mm

Aq)風車靜壓

200

5

10

15

20

25

30

35

40

45

4 6 8 10 12 14 16 18 20 22 24 26 28 30

效率(%)

20 4 6 8 10 12 14 16 18 20 22 24 26 28 30

Pin

(W)

Q(CMM)流量

Q(CMM)流量

H(Pin)M(Pin)L(Pin)

H(Eff.)M(Eff.)L(Eff.)

H(P vs. Q)M(P vs. Q)L(P vs. Q)

Design point:15CMM/20mmAq @ L speed

Page 10: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

10

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

AC FFU 900x1200 Performance Curves

Speed (HH,H,M,L) HH H M L

Air Velocity (m/s) 0.35 0.35 0.35 0.35

Air Volume (CMM) 22.7 22.7 22.7 22.7

Fan static pressure (mmAq)(unit without filter, with inlet guard) 28.4 25.5 22 17

Voltage (V) 220 220 220 220

Current (A) 1.19 1.04 0.95 0.85

Input power (W) 263 228 208 188

Efficiency(%) 40 41 39 34

Sound pressure level(dB/LpA1.5) @ H speed 54(with filter, A-weighted)

Noise criterion curve (NC) @ H speed NC-45

Octave frequency(Hz) @ H speed 63 125 250 500 1K 2K 4K 8K

Sound pressure leve(dB) @ H speed 42 58 52 47 43 41 33 20

運轉點 (Duty Point)

0

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

Ps(

mm

Aq)風車靜壓

0

5

10

15

20

25

30

35

40

45

效率(%)

40 8 12 16 20 24 28 32 36 40 44 48 52 56 60

40 8 12 16 20 24 28 32 36 40 44 48 52 56 60

Pin

,(W)

Q(CMM)流量

Q(CMM)流量

Design point:22.7CMM/17mmAq @ L speed

H(Pin)

HH(Pin)

M(Pin)

L(Pin)

HH(Eff.)H(Eff.)M(Eff.)L(Eff.)

H(P vs. Q)

HH(P vs. Q)M(P vs. Q)L(P vs. Q)

Page 11: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

11

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

AC FFU 1500x750 Performance Curves

0

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

42

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

315

Ps(

mm

Aq)風車靜壓

0

5

10

15

20

25

30

35

40

45

效率(%)

40 8 12 16 20 24 28 32 36 40 44 48 52 56 60

40 8 12 16 20 24 28 32 36 40 44 48 52 56 60

Pin

,(W)

Q(CMM)流量

Q(CMM)流量

Design point:23.6CMM/17mmAq @ L speed

H(Pin)

HH(Pin)

M(Pin)

L(Pin)

HH(Eff.)H(Eff.)M(Eff.)L(Eff.)

H(P vs. Q)

HH(P vs. Q)

M(P vs. Q)

L(P vs. Q)

Speed (HH,H,M,L) HH H M L

Air Velocity (m/s) 0.35 0.35 0.35 0.35

Air Volume (CMM) 23.6 23.6 23.6 23.6

Fan static pressure (mmAq)(unit without filter, with inlet guard) 28 25.5 22 17

Voltage (V) 220 220 220 220

Current (A) 1.22 1.07 0.97 0.87

Input power (W) 268 235 214 191

Efficiency(%) 40 42 40 34

Sound pressure level(dB/LpA1.5) @ H speed 51(with filter, A-weighted)

Noise criterion curve (NC) @ H speed NC-50

Octave frequency(Hz) @ H speed 63 125 250 500 1K 2K 4K 8K

Sound pressure leve(dB) @ H speed 40 54 57 47 45 46 32 21

運轉點 (Duty Point)

Page 12: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

12

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

AC FFU 1200x1200 Performance Curves

Speed (HH,H,M,L) HH H M L

Air Velocity (m/s) 0.35 0.35 0.35 0.35

Air Volume (CMM) 30 30 30 30

Fan static pressure (mmAq)(unit without filter, with inlet guard) 23.4 20 16 11.3

Voltage (V) 220 220 220 220

Current (A) 1.23 1.08 0.99 0.85

Input power (W) 270 238 218 188

Efficiency(%) 42 40 38 32

Sound pressure level(dB/LpA1.5) @ H speed 55(with filter, A-weighted)

Noise criterion curve (NC) @ H speed NC-45

Octave frequency(Hz) @ H speed 63 125 250 500 1K 2K 4K 8K

Sound pressure leve(dB) @ H speed 45 58 54 46 46 43 36 19

運轉點 (Duty Point)

0

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

Ps(

mm

Aq)風車靜壓

0

5

10

15

20

25

30

35

40

45

效率(%)

40 8 12 16 20 24 28 32 36 40 44 48 52 56 60

40 8 12 16 20 24 28 32 36 40 44 48 52 56 60

Pin

,(W)

Q(CMM)流量

Q(CMM)流量

Design point:30CMM/16mmAq @ M speed

H(Pin)

HH(Pin)

M(Pin)

L(Pin)

HH(Eff.)H(Eff.)M(Eff.)

L(Eff.)

H(P vs. Q)

HH(P vs. Q)

M(P vs. Q)L(P vs. Q)

Page 13: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

13

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

Speed (RPM) 1000 1100 1200

Air Velocity (m/s) 0.4 0.4 0.4

Air Volume (CMM) 20 20 20

Fan static pressure (mmAq)(unit without filter, with inlet guard) 13.2 17.8 22.7

Voltage (V) 220 220 220

Current (A) 0.39 0.51 0.61

Input power (W) 86 113 135

Efficiency(%) 50 51 55

Sound pressure level(dB/LpA1.5) @ 1100rpm 47(with filter, A-weighted)

Noise criterion curve (NC) @ 1100rpm NC-40

Octave frequency(Hz) @ 1100rpm 63 125 250 500 1K 2K 4K 8K

Sound pressure leve(dB) @ 1100rpm 37 43 48 40 36 31 25 15

運轉點 (Duty Point)

0

3

6

9

12

15

18

21

24

27

30

33

36

39

42

45

48

51

54

57

60

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

Ps(

mm

Aq)風車靜壓

0

10

15

5

20

25

35

45

55

30

40

50

60

效率(%)

40 8 12 16 20 24 28 32 36 40 44 48 52 56 60

40 8 12 16 20 24 28 32 36 40 44 48 52 56 60

Pin

,(W)

Q(CMM)流量

Q(CMM)流量

Design point:20CMM/17.8mmAq @ 1100 rpm

1000(Pin)

1100(Pin)

1200(Pin)

900(Pin)800(Pin)

1200(Eff.)

1100(Eff.)

1000(Eff.)

900(Eff.)

800(Eff.)

1000(P vs. Q)

1100(P vs. Q)

1200(P vs. Q)

900(P vs. Q)

800(P vs. Q)

DC FFU 1200x600 Performance Curves

Page 14: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

14

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

DC FFU 900x1200 Performance Curves

0

3

6

9

12

15

18

21

24

27

30

33

36

39

42

45

48

51

54

57

60

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

Ps(

mm

Aq)風車靜壓

0

10

15

5

20

25

35

45

55

30

40

50

60

效率(%)

40 8 12 16 20 24 28 32 36 40 44 48 52 56 60

40 8 12 16 20 24 28 32 36 40 44 48 52 56 60

Pin

,(W)

Q(CMM)流量

Q(CMM)流量

Design point:22.7CMM/17mmAq @ 900 rpm

1000(Pin)

1100(Pin)

1200(Pin)

900(Pin)

800(Pin)

1200(Eff.)

1100(Eff.)

1000(Eff.)

900(Eff.)

800(Eff.)

1000(P vs. Q)1100(P vs. Q)1200(P vs. Q)

900(P vs. Q)

800(P vs. Q)

Speed (RPM) 800 900 1000

Air Velocity (m/s) 0.35 0.35 0.35

Air Volume (CMM) 22.7 22.7 22.7

Fan static pressure (mmAq)(unit without filter, with inlet guard) 12 17 22

Voltage (V) 220 220 220

Current (A) 0.39 0.53 0.67

Input power (W) 86 117 148

Efficiency(%) 51 53 55

Sound pressure level(dB/LpA1.5) @ 900rpm 49(with filter, A-weighted)

Noise criterion curve (NC) @ 900rpm NC-40

Octave frequency(Hz) @ 900rpm 63 125 250 500 1K 2K 4K 8K

Sound pressure leve(dB) @ 900rpm 40 45 46 42 39 35 29 16

運轉點 (Duty Point)

Page 15: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

15

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

0

3

6

9

12

15

18

21

24

27

30

33

36

39

42

45

48

51

54

57

60

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

Ps(

mm

Aq)風車靜壓

0

10

15

5

20

25

35

45

55

30

40

50

60

效率(%)

40 8 12 16 20 24 28 32 36 40 44 48 52 56 60

40 8 12 16 20 24 28 32 36 40 44 48 52 56 60

Pin

,(W)

Q(CMM)流量

Q(CMM)流量

Design point:23.6CMM/17mmAq @ 1000 rpm

1000(Pin)

1100(Pin)

1200(Pin)

900(Pin)

800(Pin)

1200(Eff.)

1100(Eff.)

1000(Eff.)

900(Eff.)

800(Eff.)

1000(P vs. Q)

1100(P vs. Q)1200(P vs. Q)

900(P vs. Q)800(P vs. Q)

Speed (RPM) 900 1000 1100

Air Velocity (m/s) 0.35 0.35 0.35

Air Volume (CMM) 23.6 23.6 23.6

Fan static pressure (mmAq)(unit without filter, with inlet guard) 11.4 17 21

Voltage (V) 220 220 220

Current (A) 0.40 0.54 0.66

Input power (W) 87 119 146

Efficiency(%) 51 55 55

Sound pressure level(dB/LpA1.5) @ 1000rpm 49(with filter, A-weighted)

Noise criterion curve (NC) @ 1000rpm NC-40

Octave frequency(Hz) @ 1000rpm 63 125 250 500 1K 2K 4K 8K

Sound pressure leve(dB) @ 1000rpm 40 44 46 43 39 36 29 19

運轉點 (Duty Point)

DC FFU 1500x750 Performance Curves

Page 16: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

16

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

DC FFU 1200x1200 Performance Curves

0

3

6

9

12

15

18

21

24

27

30

33

36

39

42

45

48

51

54

57

60

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

Ps(

mm

Aq)風車靜壓

0

10

15

5

20

25

35

45

55

30

40

50

60

效率(%)

40 8 12 16 20 24 28 32 36 40 44 48 52 56 60

40 8 12 16 20 24 28 32 36 40 44 48 52 56 60

Pin

,(W)

Q(CMM)流量

Q(CMM)流量

Design point:30CMM/18mmAq @ 1000 rpm

1000(Pin)

1100(Pin)

1200(Pin)

900(Pin)800(Pin)

1200(Eff.)

1100(Eff.)

1000(Eff.)

900(Eff.)

800(Eff.)

1000(P vs. Q)

1100(P vs. Q)1200(P vs. Q)

900(P vs. Q)

800(P vs. Q)

Speed (RPM) 900 1000 1100

Air Velocity (m/s) 0.35 0.35 0.35

Air Volume (CMM) 30 30 30

Fan static pressure (mmAq)(unit without filter, with inlet guard) 12 18 24

Voltage (V) 220 220 220

Current (A) 0.53 0.74 0.97

Input power (W) 117 162 214

Efficiency(%) 51 55 55

Sound pressure level(dB/LpA1.5) @ 1000rpm 55(with filter, A-weighted)

Noise criterion curve (NC) @ 1000rpm NC-45

Octave frequency(Hz) @ 1000rpm 63 125 250 500 1K 2K 4K 8K

Sound pressure leve(dB) @ 1000rpm 46 55 53 43 46 42 35 19

運轉點 (Duty Point)

Page 17: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

17

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

監控系統

包含主控電腦、圖形介面操作軟體、Active Gateway、FFU控制板,依據現場需求還可以整合觸控面板及手動控制器。系統支援容餘系統架構與環型網路,增加系統穩定度。

監控電腦

CPU:INTEL 2.5G以上

RAM:8G以上

網路:10M/100M/100M標準ETHERNET TCP/IP

OS:WINDOWS 7專業版

附件:22吋LCD螢幕,鍵盤,滑鼠

圖控軟體

圖形介面操作軟體:操作軟體以視窗介面方式呈現,並配合現場位置以圖形(顏色代表)方式表示每台FFU 的運轉狀態,方便管理者了解現場情況且能迅速明確的下達相關控制指令,詳細內容請參閱內文。

可與工控系統無縫整合,支援iFIX、intouch、WinCC、圖控王…等系統。

可對單一台 FFU 下達啟/停、調整轉速等命令,及監視單一台FFU 故障訊號。

可對 FFU 群組下達啟/停、調整轉速等命令,及監視群組故障跳脫訊號,群組的設定可於系統安裝時執行,也可因需求隨時修正變更。

直覺簡單的操作,畫面上單ㄧ元件,點擊ㄧ次,可進入FFU單機控制或迴路控制畫面,直接控制,不須層層疊疊跳頁。

圖控畫面上單機與迴路,直接於平面圖標示,且可以依照轉速及故障顯示不同狀態,方便管理監控。

FFU 其運轉狀態顯示可監視轉速、停止、空載與過載等狀態。

反應速度:當圖控下達命令到回饋顯示時間,378台在8秒以內。

防誤觸系統:停止指令按鈕具有二次確認按鈕,避免誤觸停止指令導致系統停止。

歷程查詢:可依照不同的時間點,選定不同時間範圍來顯示使用歷程、異常紀錄與警報紀錄等分類紀錄,以方便使用者觀察。

操作者使用權限設定:為防止系統遭隨意更改設定導致系統無法達到正常運作,故設定操作者使用權限,將權限開放專業人員系統設定控制權限,而一般操作人員為系統操作控制權限。

管理紀錄:具登錄人員、事件、警報記錄之能力,可把操作者所做何種操作及事件、警報發生的時間、事項、人名、狀況等記錄,以區別責任。

於FFU 故障跳脫時,本系統可發出警報,以警示運轉操作人員,並於主控電腦顯示警報畫面。

通訊中繼器(Gateway)

使用Act ive Gateway,通訊方式採用乙太網路TCP/IP,一個IP字段可連接250台Gateway,共可連接94500台FFU,對FFU採用RS-485網路。

Active Gateway 主動式直接對FFU控制板通訊控制,不須監控系統,即時又快速。

Active Gateway 具有線上監視FFU之功能,可用瀏覽器直接顯示監控狀態,沒有監控系統也能方便管理使用。

可支援手動控制器與現場觸控面板,以便於現場進行FFU 測試及維修時之操作,亦可即時從電腦上得知目前的轉速及FFU 運轉狀況。

FFU控制器

提供故障、連線、及運作狀態指示燈。

每一機組上之站號可設定1~255。

AC FFU離線模式可單機設定轉速控制,方便沒監控系統與維護使用。

電源污染產生防止對策:DC控制器應有功因改善(PFC>96%)及諧波(THD<15%)抑制設計。

線材

Ethhernet網路層:CAT5E UDP,RJ45。

RS-485網路層:CAT5E UDP,RJ45或RJ11。

需採快速接頭連接電源及防止脫落裝置,以利維修。

Page 18: 組。讓我們從台灣開始,使全世界都看得到 TAIWAN-FFU

18

RCR FFU 潔淨室- 風機濾網機組 CR Fan Filter Unit

AC / DC FFU

FFU SPECIFICATION CLARIFICATION 項 目 規格

箱 體 結 構

a. 箱體結構強度要能負載人員荷重,外殼厚1.0mm,內部裝置渦殼導流以減少噪音並提升效率。

b. 上拆卸式風機組設計及保護網於上方進風口處,確保進風氣流之順暢及風機人員施工安全。

c. 箱體四邊下緣有固定導片,以利連接濾網。

箱 體 材 質 □鍍鋁鋅 □SUS430 □其它_____________

馬 達

高效馬達:□交流 ( AC馬達效率>60% ) □直流無刷 ( BLDC馬達效率□>85%□>90% )

絕緣等級:Class B insulation(130℃)/IP40

軸承壽命:L10>100,000hrs,軸心與軸承處有抗電蝕防止設計且軸電壓小於3.5V ( 直流馬達 )

扇 葉 Type: Aerofoil Fan 材質: 鋁合金。 效率:□>60% □>65%

震 動 防 止 動平衡校正須符合G2.5DIN-ISO1940 規範。

電 源 □單相220V □單相277V □其它_____________ ( □50Hz □60Hz )

F F U( c e i l i n g 尺 吋 )

□1200*600 (H327) □1200*900 (H327) □1500*750 (H327) □1200*1200 (H327)

設 計 風 量( C M M )

15/cmm 22.7/cmm 23.6/cmm 30/cmm

設 計 風 速( m / s )

0.35m/s 0.35m/s 0.35m/s 0.35m/s

設計全靜壓(Pa)須能克服濾網、擴散板、高架地板、潔淨室內、乾盤管及回風管道壓損,初始靜壓>175Pa及最終靜壓220pa時皆維持風速>0.35 m/s、並達到下列相對運轉效率。

整 機 效 率( A C F F U )

>40% >40% >40% >40%

整 機 效 率( D C F F U )

>53% >54% >55% >55%

振 動 ( 振 幅 ) <10μm <10μm <10μm <10μm

噪 音 ( d B A ) <50 <55 <55 <55

重 量 ( k g ) <23KG <39KG <37KG <48KG

馬達絕緣等級B class insulation(130°C),IP40

控製盒風車總成

AC/DC

箱體材質( 鍍鋁鋅 )

把手 Steel handlesH:327