ΨΥΞΗ ΘΕΡΜΑΝΣΗ ΜΕ ururu sarara ΤΗΣ daikin
DESCRIPTION
ΨΥΞΗ ΘΕΡΜΑΝΣΗ ΜΕ URURU SARARA ΤΗΣ DAIKINTRANSCRIPT
F U L L R A N G E
A C L A S S ENERGY LABEL
Heat pump system »
Humidification & »
dehumidification in one system
Brings fresh, »
conditioned air into the room
Improved indoor »
air quality
Inverter technology »
incorporated
FTXR-E
Heating & CoolingAir Conditioners
w w w . d a i k i n . e u
W a l l M o u n t e d U n i t
ECP010-002.indd 1 1/25/10 12:31:45 PM
Daikin’s Ururu Sarara split air conditioning unit, with
its unique system, can even heat and cool, humidify
and dehumidify, ventilate and purify the indoor air all
at the same time.
Daikin’s heat pumps are all-in-one heating and cooling
solutions, meaning comfortably warm in winter and
cool in summer. The indoor unit can be used for a pair
application - one indoor unit connected to one
outdoor unit.
The ideal solution for ideal living comfort in all seasons.
Perfect, just the way you like it.
3/4 kW
1/4 kW
4/4 kW +
Inverter technologyThe inverter technology, developed by Daikin is a true
innovation in the area of climate control. The principle is simple:
inverters adjust the power used to suit the actual requirement.
No more, no less. This technology provides you with two concrete
benefits:
ComfortThe inverter repays its investment many times over by improving
comfort. An air conditioning system with an inverter continuously
adjusts its cooling and heating output to suit the temperature in
the room. The inverter shortens system start-up time enabling
the required room temperature to be reached more quickly. As
soon as that temperature is reached, the inverter ensures that it
is constantly maintained.
Energy efficient
Because an inverter monitors and adjusts ambient temperature
whenever needed, energy consumption drops by 30% compared
to a traditional on/off system! (non inverter)
Did you know that ...Air to air heat pumps use 3/4th of energy from renewable sources:
the ambient air. This energy source is renewable and inexhaustible*.
Of course, heat pumps also use 1/4th of electricity to run the
system, but increasingly this electricity can also be generated from
renewable energy sources (solar energy, wind energy, hydropower,
biomass). A heat pump’s efficiency is measured in COP (Coefficient
Of Performance) for heating and EER (Energy Efficiency Ratio) for
cooling. Heat pumps achieve COPs of up to 5.14 (for FTXR28E)!
* EU objective COM (2008)/30
ambient temperature
energy
electricity
Slow start
Temperature remains stableTemperature / Power input
Time
Set temp. Air conditioning with Inverter
Air conditioning without Inverter
Heating operation:
Combining highest efficiency and year-round comfort with a heat pump system
ECP010-002.indd 2 1/25/10 12:31:47 PM
Design & technological qualityThe Ururu Sarara received the distinguished ‘Good Design Award’,
the unique evaluation criterion for industrial design in Japan.
5 air treatment techniques in 1 system
1. Humidification, even during heatingFor the humidification, called ‘Ururu’ in Japanese, moisture is
absorbed from the outdoor unit and streams into the indoor unit
where it is evenly distributed troughout the room. The advantages
of humidity are preventing sore throats, dry skin and making the
human body feel warmer, even at lower temperatures, thus
reducing heating demand and energy consumption.
2. Dehumidification,
without a drop in temperatureDehumidification, or ‘Sarara’ in Japanese, reduces indoor humidity,
without effecting the room temperature, by mixing cool, dry air
with warm air. So no hot and stuffy rooms any more!
Night set mode:1. saves energy, by preventing
overcooling or -heating during night time
Comfort mode:2. prevents cold or warm air
blowing directly on the body
3D air distribution:3. combination of vertical
and horizontal auto-swing to circulate the air
evenly in even large rooms or corners
Whisper quiet operation:4. the sound of the
indoor units is that low that it can be compared
to rustling leaves
For your personal comfortFollowing features have been incorporated
Temp. : 25°CTemp. : 25°C
Humidity : 80%Hot humid feeling
Humidity : 50%Comfortable feelingSarara
Temp. : 22°CTemp. : 22°C
Humidity : 20%Cold feeling
Humidity : 50%Comfortable feelingUruru
3. Improved indoor air quality thanks
to Daikin’s flash streamer technologyExhaust gases and unpleasant odours are
removed via the outdoor unit. Afterwards
the indoor unit purifies the air on dust, pollen,cigarette smoke
and cooking odours. It also breaks down viruses and moulds.
4. Ventilation,
fresh air even with closed windowsFresh, conditioned air is brought into the room, without cold or
heat loss. The temperature of the incoming air is brought at the
desired level.
5. Heat pump systemThe Ururu Sarara not only offers the possibility of cooling in
summer, it can also provide warmth in cold winters.
ECP010-002.indd 3 1/25/10 12:31:49 PM
Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende
Daikin products are distributed by:
The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.
FSC
ECPEN10-002Daikin Europe N.V. participates in the Eurovent Certification Programme for Air Conditioners (AC), Liquid Chilling Packages (LCP) and Fan Coil Units (FC); the certified data of certified models are listed in the Eurovent Directory. Multi units are Eurovent certified for combinations up to 2 indoor units.
Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.
The
pres
ent p
ublic
atio
n su
pers
edes
ECP
EN09
-002
.Pr
inte
d on
non
-chl
orin
ated
pap
er. P
repa
red
by L
a M
ovid
a, B
elgi
um
Resp
. Ed.
: Dai
kin
Euro
pe N
.V., Z
andv
oord
estr
aat 3
00, B
-840
0 O
oste
nde
Outdoor UnitRXR28,42,50E
Infrared Remote ControlARC447A1
Indoor UnitFTXR28,42,50E
Heating & CoolingINDOOR UNITS FTXR28E FTXR42E FTXR50E
Capacitycooling min~nom~max kW 1.55~2.8~3.60 1.55~4.2~4.60 1.55~5.0~5.50heating min~nom~max kW 1.30~3.6~5.00 1.30~5.1~5.60 1.30~6.0~6.20
Power inputcooling min~nom~max kW 0.25~0.56~0.80 0.26~1.05~1.32 0.26~1.46~1.80heating min~nom~max kW 0.22~0.70~1.41 0.22~1.18~1.60 0.23~1.51~1.77
EER cooling 5.00 4.00 3.42COP heating 5.14 4.32 3.97
Energy labelcooling Aheating A
Annual energy consumption cooling kWh 280 525 730Dimensions height x width x depth mm 209x890x305Weight kg 14Front panel colour White
Air flow ratecooling H / M / L / SL m3/min 11.1/8.8/6.5/5.7 12.4/9.6/6.8/6.0 13.3/10.3/7.3/6.5heating H / M / L / SL m3/min 12.4/9.8/7.3/6.5 12.9/10.2/7.7/6.8 14.0/11.1/8.3/7.3
Sound pressure levelcooling H / M / L / SL dBA 39/33/26/23 42/35/27/24 44/37/29/26heating H / M / L / SL dBA 41/35/28/25 42/36/29/26 44/38/31/28
Sound power levelcooling dBA 55 58 60heating dBA 57 58 60
Power supply 1~/ 220-240V /50HzRemote control infrared ARC447A1
OUTDOOR UNITS RXR28E RXR42E RXR50EDimensions height x width x depth mm 693x795x285Weight kg 48Compressor type Hermetically sealed swing
Sound powercooling dBA 60 62heating dBA 60 62 64
Refrigerant type R-410AAdditional refrigerant charge kg/m Chargeless
Operation rangecooling min~max °CDB -10~43heating min~max °CWB -20~18
Piping connectionsliquid mm ø6.35gas mm ø9.52drain ID mm ø18
Sound pressure cooling High dBA 46 48heating High dBA 46 48 50
Maximum piping length m 10Maximum installation height difference m 8Power supply 1~ / 220~240V / 50Hz
Notes: 1) Energy label: scale from A (most efficient) to G (least efficient) - 2) Annual energy consumption: based on average use at 500 running hours per year full load (= nominal conditions). - 3) V1 = 1=, 220-240V, 50Hz - 4) Nominal cooling capacities are based
please refer to the technical data books) - 8) The sound power level is an absolute value indicating the “power” which a sound source generates.
ECP010-002.indd 4 1/25/10 12:31:55 PM
Cert no. SGS-COC-006250
ECPEN10-002