0 0 3urjudpplqj 6whsv &rqfrug - dynamark …s1 p1 g28 no hw key *** get back to s set to contact...
TRANSCRIPT
M2M Programming Steps - Concord 4M2M Programming Steps - Concord 4M2M Programming Steps - Concord 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 16.5 VAC GND +12V A R SPKR SPKR OUT1 OUT2 + 2 MIC GND ZONE1 ZONE2 GND ZONE3 ZONE4 GND ZONE5 ZONE6 GND ZONE7 ZONE8 GRN BRN GRv RED
Gray (GND)
Red (+12V)
Green (ring)
Resistor (Accross Zone)
Yellow (tip)
Orange (Zone)
White (Out2)
M2M Programming Steps - Concord 4
Program Keyswitch zone:
Keypad Display Enter on Keypad Comments
System Programming 0014 This enters the keyswitch sensor area
Key Switch Sensor X#, B X = Zone Number 1-8, # to confirm, press B to get key switch style
Key Switch Style Transition B *** Press B until Displays TRANSITION. Then press * a few times to get back to the System Programming
System Programming 080 Enters the Learn Sensors menu
Learn Sensors # # opens this menu
Sensors PTN 1 `# This is the partition area, with 1 as default. Do not change if 1, press # to confirm
Sensor Group 0 28 # Change Sensor Group to 28, # to confirm
Trip Sensor X * Navigate to chosen zone X (1-8), Short Zone X wire to GND wire. Wait for the panel to beep, press * until Learn Sensors prompt displays
Learn Sensors A To get to edit sensor area
Edit Sensors # View sensor 1
S1 P1 G28 NO HW KEY *** Get BACK to S
Set to Contact ID
Keypad Display Enter on Keypad Comments
System Programming 01006 To display Reporting Format
Reporting Formatting “Type”
2, # *** “TYPE” is the current programmed types, 2 is for CID, # to confirm, hit *** to get to System Programming.
________________________________________________________________________ 525 Northern Ave, Hagerstown, MD 21742 • (855) 875-7233 • www.DynamarkMonitoring.com