Skylar Compliance and Performance Overview

Upload: educational-solutions-worldwide-inc

Post on 17-Mar-2016

215 views

Category:

Documents


0 download

DESCRIPTION

                                                              EMAIL:    [email protected]        

TRANSCRIPT

Page 1: 008-Skylar Compliance & Performance Overview V3

                                                         

Skylar Compliance and Performance Overview

   

Page 2: 008-Skylar Compliance & Performance Overview V3

  THE  SKYLAR  PROJECT:    FÁBRICA  NETWORK  300  NEW  TORONTO  STREET,  SUITE  3600,  M8V  2E8  TORONTO,    ONTARIO,  CANADA  TEL:  +1  647  977  9176  or  TEL:    +1  888  788  8034,    FAX:  +1  888  588  1945  EMAIL:    [email protected]  

 

                1  

 

©  The  Skylar  Project  2011.    All  rights  Reserved    NOTICE OF CONFIDENTIALITY This document including any information transmitted with it is intended only for the use of the addressees and is confidential. If you are not an intended recipient or responsible for delivering the message to an intended recipient, any review, disclosure, conversion to hard copy, dissemination, reproduction or other use of any part of this communication is strictly prohibited, as is the taking or omitting of any action in reliance upon this document. If you receive this document in error or without authorization please notify us immediately or otherwise and permanently delete the entire document from any computer, disk drive, or other storage medium.

Page 3: 008-Skylar Compliance & Performance Overview V3

  THE  SKYLAR  PROJECT:    FÁBRICA  NETWORK  300  NEW  TORONTO  STREET,  SUITE  3600,  M8V  2E8  TORONTO,    ONTARIO,  CANADA  TEL:  +1  647  977  9176  or  TEL:    +1  888  788  8034,    FAX:  +1  888  588  1945  EMAIL:    [email protected]  

 

                2  

 

International  Building  Code  Compliance  Fact  Sheet  

Overview  

Provide  modular  building  structures  for  residential  and  commercial  applications  that  meet  and  exceed  International  Building  Code  compliance.      

Description  

Wall  and  roof  systems  designed  from  light  gage  steel,  EPS  and  EFIS  materials.    All  raw  materials  are  accepted  in  regular  building  practices  internationally.  The  unique  fabrication  process  utilizes  these  products  in  a  modular  construction  form.  All  fasteners  meet  or  exceed  building  regulation  internationally.  

Exterior  Material  

• Exterior  EFIS  (cement  like  material)  to  meet  and  exceed  international  Building  Code  2004  

• Exterior  EPS  (Expanded  Poly  Styrene)  to  meet  thermal  performance  values  of  R15  on  average.  

• Exterior  IBS  Roof  System  engineered  and  tested  to  meet  any  dead  load  requirements  for  the  International  Building  Code  2004.  

• Exterior  Roof  tile  or  shingle  to  meet  International  Building  Code  2004.  • Exterior  windows  and  doors  to  meet  or  exceed  energy  compliance  as  well  as  air,  

water  and  structural  requirements.  Low  E  coatings  available  to  achieve  higher  U-­‐Values.    

Internal  Material  

• Internal  EFIS  and  EPS  material  help  achieve  even  higher  thermal  performance.  Exceeds  R15  with  this  option  (performance  up  to  R60  is  also  possible)  

• Internal  Drywall  allows  a  minimum  of  45  min  fire  rating  where  required.  • Interior  light  gauge  studs  within  EPS  walls  are  a  minimum  of  18  gauge  which  

exceed  International  Building  Regulations  for  exterior  walls  being  24  or  even  26  gauge.  

• All  Steel  members  to  be  a  minimum  of  galvanized  or  galvalume  90.  This  exceeds  general  building  code  which  is  generally  galvalume  40  or  less.  

• All  interior  plumbing  and  electrical  to  be  International  Code  Complaint.  

Conclusion  

All  raw  materials  and  fastening  methods  are  derived  from  current  accepted  building  code  compliance  products.  Skylar  building  can  be  adapted  to  meet  code  in  virtually  any  country.  

Page 4: 008-Skylar Compliance & Performance Overview V3

  THE  SKYLAR  PROJECT:    FÁBRICA  NETWORK  300  NEW  TORONTO  STREET,  SUITE  3600,  M8V  2E8  TORONTO,    ONTARIO,  CANADA  TEL:  +1  647  977  9176  or  TEL:    +1  888  788  8034,    FAX:  +1  888  588  1945  EMAIL:    [email protected]  

 

                3  

 

Skylar  Wall  Panel  Product  Performance  Test Test Method Criteria Results Air Leakage ASTM E 283 No Criteria 0.6l/min/m2 (0.002

cfm/ft2) Water Penetration ICC ES (AC 212)

ASTM E 331 No water penetration beyond the inner-most plane for the wall after 15 minutes at 137 Pa (2.86 Psf for drainage systems and after 2 hours at 300 Pa (6.24 Psf) for barrier systems

Passed

Drainage Efficiency ICC ES (AC 235)

ASTM E 2273 Minimum Drainage Efficiency of 90%

Passed

Accelerated Weathering

ASTM G 155 Cycle 1 ASTM G 154 Cycle 1 (QUV)

No deleterious effects after 2000 hours

No deleterious

Freeze Thaw (formerly EIMA 101.01)

ASTM E 2485 No deleterious effects after 60 cycles

Passed – No deleterious effects after 90 cycles

Impact Resistance (formerly EIMA Std. 101.86)

ASTM E 2486 No fracture of reinforcing mesh

Meets all requirements in each mesh category

Transverse Wind Load

ASTM E 330 Withstand positive and negative loads as specified by the building code

Minumum 4.3 kPa (90 Psf)* 16 inch o.c. framing, .5 in. sheathing screw attached at 203 mm (8 inch) o.c.

Fire Resistance ASTM E 119 NFPA 268

No effect of a rated wall assembly

Passed 1 hour

Intermediate Multi-story Fire Test

NFPA 285 (UBC 26-9) 1. Resist flame propagation over the exterior surface 2. Resist vertical spread of flame within combustible core/component of panel from one story to the next 3. Resist vertical spread of flame over the interior surface from one story to the next 4. Resist lateral spread of flame from the compartment of the fire of origin to the adjacent spaces

Passed

Full Scale Multi-Story (corner test)

ANSI FM 4880 Resist flame propagation over the exterior surface

Passed; No height restrictions for Outsulation of Outsulation Plus MD

 Additional  product  performance  information  is  available  on  request.    Product  performance  may  vary  according  to  specific  implementation,  as  building  code  and  engineering  specifications  may  call  for  additional  criteria  to  be  considered.        

Page 5: 008-Skylar Compliance & Performance Overview V3

ENGLISH

EATON DONALDTHE SKYLAR PROJECT: FÁBRICA NETWORK

300 New Toronto Street, Suite 3600Toronto, Ontario, M8V 2E8TEL: +1 647 977 933 9090, FAX: +1 888 588 1945EMAIL: [email protected]

PORTUGUESE

MANUEL LIMATHE SKYLAR PROJECT: FÁBRICA NETWORK

300 New Toronto Street, Suite 3600Toronto, Ontario, M8V 2E8

TEL: +1 416 8915818 FAX: +1 888 588 1945

EMAIL: [email protected]

For more information, contact:

Page 6: 008-Skylar Compliance & Performance Overview V3

© The Skylar Project 2011. All Rights Reserved