01 tuong phan

43
Advances in haemodynamic monitoring in Anaesthesia and ICU Dr Tuong Phan Staff Specialist Anaesthetist Dept Anaesthesia and Pain Medicine St Vincent’s Hospital Melbourne

Upload: duy-quang

Post on 14-Jul-2015

169 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: 01 tuong phan

Advances in haemodynamic monitoring in Anaesthesia and ICU

Dr Tuong PhanStaff Specialist Anaesthetist

Dept Anaesthesia and Pain MedicineSt Vincent’s Hospital Melbourne

Page 2: 01 tuong phan

the technologyBeyond standard monitoringKeys to understanding

Recommendations and summary

utilityAccuracyTrending ability

utilityClinical studies

Min

imal

ly in

vasi

ve c

ardi

ac o

utpu

t m

onito

ring

Min

imal

ly in

vasi

ve c

ardi

ac o

utpu

t m

onito

ring

Page 3: 01 tuong phan

Method Proprietary device Invasive elements Parameters

Oesophageal Doppler

CardioQTM, Deltex Medical Oesoph. Doppler probe

CO, SV, Ftc

CardioQ PLUS OD plus arterial line

CO, SV

Transcutaneous Doppler

Ultrasound CO monitor, USCOMTM

Nil CO, SV

APCO uncalibrated

Vigileo/FloTracTM, Edwards Lifesciences (1)

Arterial line CO, SV, SVV

LiDCO Rapide, LiDCO Ltd Arterial line CO, SV, SVV, PPV

Finepress, Nexfin, Edwards Finger cuff CO, SV, SVV

Arterial Pressure CO calibrated

LiDCO Plus, LiDCO Ltd (2) Arterial line CO, SV, SVV, PPV

PiCCOplusTM, Pulsion Medical Systems

Central Venous catheter and femoral arterial line

CO, SV, ITBV, EVLW

Plethysmography Masimo Rainbow SET Pulse CO, Masimo Corp.

Pulse oximeter dPOPPVI

Min

imal

ly in

vasi

ve c

ardi

ac o

utpu

t m

onito

ring

Min

imal

ly in

vasi

ve c

ardi

ac o

utpu

t m

onito

ring

Page 4: 01 tuong phan

Method Proprietary device Invasive elements Parameters

Oesophageal Doppler

CardioQTM, Deltex Medical Oesoph. Doppler probe

CO, SV, Ftc

CardioQ PLUS OD plus arterial line

CO, SV

Transcutaneous Doppler

Ultrasound CO monitor, USCOMTM

Nil CO, SV

APCO uncalibrated

Vigileo/FloTracTM, Edwards Lifesciences (1)

Arterial line CO, SV, SVV

LiDCO Rapide, LiDCO Ltd Arterial line CO, SV, SVV, PPV

Finepress, Nexfin, Edwards Finger cuff CO, SV, SVV

Arterial Pressure CO calibrated

LiDCO Plus, LiDCO Ltd (2) Arterial line CO, SV, SVV, PPV

PiCCOplusTM, Pulsion Medical Systems

Central Venous catheter and femoral arterial line

CO, SV, ITBV, EVLW

Plethysmography Masimo Rainbow SET Pulse CO, Masimo Corp.

Pulse oximeter dPOPPVI

Min

imal

ly in

vasi

ve c

ardi

ac o

utpu

t m

onito

ring

Min

imal

ly in

vasi

ve c

ardi

ac o

utpu

t m

onito

ring

Page 5: 01 tuong phan

V = ∆f c .

2 ft cosθ

the technology

Oesophageal Doppler Monitor

Page 6: 01 tuong phan

Stroke Distance

SV = VTI x Area

SV = VTI/0.7 x est desc Aortic area

∆CO ∝ ∆VTI

Page 7: 01 tuong phan

Afterload Increase Afterload Reduction

Positive InotropyMyocardial Depression

Preload Reduction Preload Increase Predominant Change

Page 8: 01 tuong phan

Keys to

Oesophageal Doppler Monitor

• ∆CO ∝ ∆VTI– Good diagnostic and trend ability– Uncoupled from pressure entirely

• Continuously available• Learning curve

Page 9: 01 tuong phan

Method Proprietary device Invasive elements Parameters

Oesophageal Doppler

CardioQTM, Deltex Medical Oesoph. Doppler probe

CO, SV, Ftc

CardioQ PLUS OD plus arterial line

CO, SV

Transcutaneous Doppler

Ultrasound CO monitor, USCOMTM

Nil CO, SV

APCO uncalibrated

Vigileo/FloTracTM, Edwards Lifesciences (1)

Arterial line CO, SV, SVV

LiDCO Rapide, LiDCO Ltd Arterial line CO, SV, SVV, PPV

Finepress, Nexfin, Edwards Finger cuff CO, SV, SVV

Arterial Pressure CO calibrated

LiDCO Plus, LiDCO Ltd (2) Arterial line CO, SV, SVV, PPV

PiCCOplusTM, Pulsion Medical Systems

Central Venous catheter and femoral arterial line

CO, SV, ITBV, EVLW

Plethysmography Masimo Rainbow SET Pulse CO, Masimo Corp.

Pulse oximeter dPOPPVI

Min

imal

ly in

vasi

ve c

ardi

ac o

utpu

t m

onito

ring

Min

imal

ly in

vasi

ve c

ardi

ac o

utpu

t m

onito

ring

Page 10: 01 tuong phan

CO-from-ABP

• MAP positively but imperfectly correlates with CO– Variable changes in SVR make

MAP unreliable– ABP waveform analysis

assumes other features are less affected by confounders such as Vascular resistance

• MAP is a control in Sun et al

Page 11: 01 tuong phan

CO-from-ABP

• All 8 methods superior to MAP as directional qualitative indicators of major changes in CO-Thermodilution

• Differ drastically in magnitude. Only one method was superior than MAP when comparing limits of agreement cf CO.

8 different algorithms8 different algorithms

Cardiac Index: 95% limits of agreement l/min

Liljestrand*** -1.76 1.41Corr Impedance -1.91 1.57Pulse Pressure -2.07 1.73Systolic Area -2.07 1.73Sys Area with Kouchoukos corr -2.08 1.71AC power RMS -2.09 1.73Diastolic decay -2.23 1.77MAP -2.20 1.82Herd -2.66 1.89

Page 12: 01 tuong phan

SPV

Respiratory coupled parameters

Inspiration- blood squeezed from lung- ↑LV preload ↑systemic BP

↑intrathoracic pressure ↓ RV preload ↓ RV stroke vol

Page 13: 01 tuong phan

Respiratory coupled parametersPerel, CCM 2009

SPV SVVPPV

Page 14: 01 tuong phan

© 2011 International Anesthesia Research Society . Published by International Anesthesia Research Society.2

Respiratory Variation in Pulse Pressure and Plethysmographic Waveforms: Intraoperative Applicability in a North American Academic Center.Maguire, Sinead; Rinehart, Joseph; Vakharia, Shermeen; Cannesson, Maxime; MD, PhD

Anesthesia & Analgesia. 112(1):94-96, January 2011.DOI: 10.1213/ANE.0b013e318200366b

Respiratory coupled parameters

Page 15: 01 tuong phan

the technologyPiCCO injection

t

T

P

t

Transpulmonary thermodilution calibrationPulse contour analysis

Page 16: 01 tuong phan

the keys

PiCCO

• Requires femoral arterial line• Requires central line• Calibrated• Provides additional

haemodynamic variables• Continuous CO

Page 17: 01 tuong phan

LiDCOplusTM

Proprietary algorithm - PulseCOTM

the technology

Page 18: 01 tuong phan

LiDCOrapidTM

Proprietary algorithm - PulseCOTM

Uncalibrated

Cardiac Index

SVV

PPV - Pulse Pressure Variation

Page 19: 01 tuong phan

the keys to

LiDCO Plus and Rapid

• Fick principle Lithium dilution calibration• Pulse power algorithm

– “Morphology independent”

• Arterial line required but utilises data cable from standard monitoring system. No specific transducer is needed

Page 20: 01 tuong phan

the technology

Vigeleo Flotrac

• Arterial pulsatility - sd of pressure wave

• K• sex, age, ht and wgt• Waveform characteristics

(skewness and kurtosis)

Page 21: 01 tuong phan

the technologyVigeleo Flotrac

• Graphic User Interface: • “Drive screen”

• Graphic User Interface: • “Trend screen”

Page 22: 01 tuong phan

• GUI– Additional

functionality– ScvO2– GEDI and ELWI

the technology

Vigeleo Flotrac

Page 23: 01 tuong phan

the keys to

Vigeleo Flotrac

• Equipment: arterial line• Flow sensor connected directly to arterial line• Accuracy has been dependent on software

upgrades/version.– Previously struggled with changes in compliance,

low SVR states– version 4 being released.

Page 24: 01 tuong phan

the technology

Nexfin, aka Finepress • Volume clamp with finger cuff• HRS: heart reference system

– measures and corrects pressure difference btw finger and heart•200Hz sampling rate

• Stroke Volume – 3 element Windkessel model• Up to 12% may have inadequate signal

Page 25: 01 tuong phan
Page 26: 01 tuong phan

Fischer M O et al. Br. J. Anaesth. 2012;109:514-521

© The Author [2012]. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: [email protected]

• Nexfin and arterial pressure– MAP

correlates well– SBP

underestimates

– CI has looser agreement

the technology

Finepress

Page 27: 01 tuong phan

Edwards EV1000

• EV1000– Flotrac– Nexfin– VolumeView– ScVO2

– PAC thermodilution

Page 28: 01 tuong phan

the technologyMasimo• Pulse oximetry• Plethysmographic

variability index (PVI)– It measures the dynamic

changes in perfusion index (PI) over respiratory cycles and calculated as follows:

– PVI = [(PImax – PImin)/PImax] x 100%.

• ∆POP• COHb• Continuous Hb

Page 29: 01 tuong phan

utilityAccuracy

• Peyton and Chong– Anesthesiology 2010

• Metaanalysis 4 CO monitor types

• Mean bias, precision, percentage error cf thermodilution

• All 40%• Limitation of BA is the

reference TD

Page 30: 01 tuong phan

limitations Accuracy

TD vs OD TD vs FT TD vs Li

Page 31: 01 tuong phan

limitations Accuracy

Lorsomradee, JCVA 2009

Page 32: 01 tuong phan

Truly Not Fluid Responsive

Accuracy: “functional” vs static, receiver operating curves

Trul

y Fl

uid

Resp

onsi

ve

22%

12%

5%

Page 33: 01 tuong phan

utilityAccuracy• Marik et al, CCM 2009

Summative ROC area

PPV (n=19)0.94 (0.92-0.96)

SVV 0.84 (n=5) (0.81-0.87)

CVP 0.55GEDI 0.56

Page 34: 01 tuong phan

Limitations : comparison of SVV

• LiDCO SVV cf FT SVV• Large percentage

error• Different methods of

calculating SV• Not interchangeable

Page 35: 01 tuong phan

utilityClinical Application

Stroke volume based parameters

Page 36: 01 tuong phan

utilityClinical Application

Respiratory coupled parameters

Page 37: 01 tuong phan

Survey of tools for GDT

Page 38: 01 tuong phan

Oesoph dopplerClinical Application

Page 39: 01 tuong phan

Oesoph Doppler

(1) Use the Stroke Volume Index (SVI); average over 10 cycles(2) Hypotension can be absolute or relative(3) A large change in the SV, ie. >10%, represents the fluid responsiveness(4) A small change in the SV, ie <10% represents the plateau phase and represents an optimised preload(5) Once an optimised phase is reached, a fluid bolus should be given if the SVI falls >10% * The Doppler values will vary from measurement to measurement. However, a trend over several measurements will be more informative.

Page 40: 01 tuong phan

Arterial Pressure CO algorithm

Page 41: 01 tuong phan

“Optimal Fluid therapy”

Opt

imum

Incr

easi

ng

Mor

bidi

ty

HypervolemiaHypovolemia

Min

imal

ly in

vasi

ve c

ardi

ac o

utpu

t m

onito

ring

Min

imal

ly in

vasi

ve c

ardi

ac o

utpu

t m

onito

ring

Editorial “Wet, dry or something else?”

Bellamy, BJA 97 (6), Dec2006

Page 42: 01 tuong phan

my observations

• Mythen and Hamilton 1995 ICM

• Exanguinate 6 healthy volunteers– BP drops modestly– SV drops markedly

Page 43: 01 tuong phan

the technologyDoppler, APCO, Plethysmography

recommendations and summaryThey are just monitors. Outcomes will be dependent on how they

are utilised to make decisions

utility: Accuracy and Trending abilityKeep in mind the key parameters, their underlying assumptions and be critical. Nevertheless estimations of stroke volume, respiratory coupled parameters do represent a significant addition to standard monitoring eg. Arterial pressure, urine output, CVP

utility: Clinical studiesDevices can be used to target the delivery of fluids and inotropes

Min

imal

ly in

vasi

ve c

ardi

ac o

utpu

t m

onito

ring

Min

imal

ly in

vasi

ve c

ardi

ac o

utpu

t m

onito

ring