05 sep-601 pcm 600_1p5_smt

18
1 © ABB Power Technologies AB, 2007 2007-09-07 Substation Automation and Protection Training PCM 600 Signal Matrix Tool – SMT Line Data Communication Module – LDCM HMI LED Substation Automation and Protection Training 3 © ABB Power Technologies AB, 2007 2007-09-07 Substation Automation and Protection Training Inputs/Outputs in CAP531 are Hardware Independent

Upload: himdad-tahir

Post on 20-Oct-2015

22 views

Category:

Documents


1 download

DESCRIPTION

PCM 600_1p5_SMT

TRANSCRIPT

Page 1: 05 SEP-601 PCM 600_1p5_SMT

1

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

PCM 600Signal Matrix Tool – SMTLine Data Communication Module – LDCMHMI LED

Substation Automation and Protection Training

3

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

Inputs/Outputs in CAP531 are Hardware Independent

Page 2: 05 SEP-601 PCM 600_1p5_SMT

4

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

Signal Matrix Tool – SMT

SMT is the tool to define relationship between VIRTUAL INPUT/OUTPUT signals (Analog or Digital) and REAL INPUT/OUTPUT signals (Analog or Digital).

5

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – How it works in practice

Binary Input

N. 1

0

0 Vdc

CAP 531 Configuration

Page 3: 05 SEP-601 PCM 600_1p5_SMT

6

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – How it works in practice

Binary Input

N. 1

1

Vdc

CAP 531 Configuration

7

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – The result of settings

CAP531

BINARY INPUT CARD IN SLOT 3

SMT

Page 4: 05 SEP-601 PCM 600_1p5_SMT

8

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – Virtual and Real Binary Outputs

THIS IS WHAT YOU DO IN CAP 531:

Signal Matrix Binary Output (”Virtual Binary Output Block”)

9

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – Binary Outputs

THIS IS WHAT YOU DO IN SIGNAL MATRIX TOOL:

x

xx

x

x

x

Page 5: 05 SEP-601 PCM 600_1p5_SMT

10

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – The result of Output Configuration

SMT

CAP531

BINARY OUTPUT CARD IN SLOT 6

11

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – Configuration of Analog Inputs in CAP 531

Also CAP 531 configuration of Analog Inputs (CTs, VTs) is NOT Hardware Dependent:

Page 6: 05 SEP-601 PCM 600_1p5_SMT

12

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – Configuration of Analog Inputs in CAP 531

Pre Processing Block (”Virtual Analog Input Block”) for CURRENT measurements.

Pre Processing Block (”Virtual Analog Input Block”)for VOLTAGE measurements.

Currents information in CAP531

Voltages information in CAP531

I

U

13

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – Analog Input Configuration

CTs assignment

VTs assignment

Page 7: 05 SEP-601 PCM 600_1p5_SMT

14

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – Residual quantity: measured or calculated?

15

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – Residual quantity: measured or calculated?

Page 8: 05 SEP-601 PCM 600_1p5_SMT

16

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – Residual quantity: measured or calculated?

17

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – Residual quantity: measured or calculated?

Page 9: 05 SEP-601 PCM 600_1p5_SMT

18

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

LDCM – Configuration

LDCM configuration (communicationamong different IEDs via ….,IEDs are usually positioned in different stations,will take place in SMT.

19

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

LDCM – Analog Type (Line Diff)

LDCM cards are defined by using CAP 531(Function Selector)

Page 10: 05 SEP-601 PCM 600_1p5_SMT

20

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

LDCM – Current Configuration (Line Diff)

Receive Currents from remote terminal

21

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

LDCM – Current Configuration (Line Diff)

SEND Currents to remote terminal

Page 11: 05 SEP-601 PCM 600_1p5_SMT

22

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

LDCM – Current Configuration (Line Diff)

Receive Currents from remote terminal

SE

ND

Cu

rren

tsto

re

mo

te t

erm

inal

23

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

LDCM – Current Configuration (Line Diff)

LOCAL CURRENTS

REMOTE CURRENTS

Page 12: 05 SEP-601 PCM 600_1p5_SMT

24

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

LDCM – How many currents can I send?

It seems I can ”send” 8 currents…..

…. But I can just receive 4 currents!

Answer is in settings of the LDCM card!

25

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

LDCM – Analog Type and Binary Signal Configuration

With LDCM Analog Card you can SEND (TX) 8 binary signals!

Page 13: 05 SEP-601 PCM 600_1p5_SMT

26

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

LDCM – Analog Type and Binary Signal Configuration

With LDCM Analog Card you can RECEIVE (RX) 8 binarysignals!

27

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

LDCM – Binary Type

NOT for Line DIFF terminals! (only Analog Type LDCM card is allowed for them)

LDCM card is entered

By using CAP531/Function Selector

Possibility to SEND (and receive) 6 x 32 binary signals TO (from) remote terminal

Page 14: 05 SEP-601 PCM 600_1p5_SMT

28

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

LDCM – Binary Type – SMT

Receive Binary Signals from remote terminal6 x 32

32

29

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

LDCM – Binary Type – CAP 531

Page 15: 05 SEP-601 PCM 600_1p5_SMT

30

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

LDCM – Binary Type – RX PART

Receive Binary Signals from remote terminal

31

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

LDCM – Binary Type – TX PART

SEND Binary Signals TO remote terminal

Page 16: 05 SEP-601 PCM 600_1p5_SMT

32

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – HMI LED Configuration

Not used

Used Used (Binary Outputs)

33

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – HMI LED Configuration

Not used

Used

Used (Binary Inputs)

Page 17: 05 SEP-601 PCM 600_1p5_SMT

34

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – Read from the IED

Open SMT and read data from IED

35

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – Read from the IED

BEFORE….

Page 18: 05 SEP-601 PCM 600_1p5_SMT

36

©A

BB

Po

we

r T

ech

no

log

ies

AB

, 2

00

7

2007-09-07 Substation Automation and Protection Training

SMT – Read from the IED

Save and Exit from SMT.

AFTER….