1 2 3 4 5 gambrell 153 auditorium university of south...

11
N LOCATION MAP SCALE: N.T.S. 1 2 3 4 5 A B C D SHEET OF 1301 Gervais Street, Suite 1300 Columbia, SC 29201 Phone (803) 799-6502 www.pondco.com SHEET ID 1301 Gervais Street, Suite 1300 Columbia, SC 29201 Phone (803) 799-6502 www.pondco.com SIZE: ANSI D FILE NAME: SUBMITTED BY: CHECKED BY: DRAWN BY: DESIGNED BY: ISSUE DATE: SOLICITATION NO.: CONTRACT NO.: FILE NUMBER: Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company. STAMP/SEAL 7 Clusters Court, Suite 201 Columbia, SC 29210 Phone (803) 731-0650 www.bea-consulting.com BELKA ENGINEERING ASSOCIATES, INC. 1 / 1 4 / 2 0 2 0 1 1 : 0 8 : 4 8 P M C : \ U s e r s \ w h i t e l \ D o c u m e n t s \ U S C G a m b r e l l A u d i t o r i u m _ A r c h - I _ v 1 9 _ w h i t e l 2 6 X 5 B . r v t G-001 CONSTRUCTION DOCUMENTS PROJ. NO.: H27-Z407 50003375-2 CONSTRUCTION DOCUMENTS 15 JANUARY 2020 COLUMBIA, SOUTH CAROLINA COVER SHEET GAMBRELL 153 AUDITORIUM UNIVERSITY OF SOUTH CAROLINA COLUMBIA, SOUTH CAROLINA UNIVERSITY OF SOUTH CAROLINA GAMBRELL HALL, 817 HENDERSON STREET COLUMBIA, SOUTH CAROLINA 29208 JOB NO. 1200321 LSW AH LM 15 JANUARY 2020 PROJ. NO.: H27-Z407 50003375-2 PROJ. NO.: H27-Z407 50003375-2 PROJECT LOCATION GAMBRELL HALL SHEET INDEX SHEET NUMBER SHEET NAME GENERAL G-001 COVER SHEET LS-101 LIFE SAFETY PLAN ARCHITECTURAL A-001 GENERAL NOTES AND ABBREVIATIONS A-002 PARTITION TYPES & DETAILS AD101 DEMOLITION PLANS A-101 RENOVATION PLANS A-301 SECTION/ELEVATION & DETAILS A-601 DOOR SCHEDULE & DETAILS A-631 FINISH SCHEDULE & FURNITURE PLAN ELECTRICAL E-001 ELECTRICAL DEMOLITION PLAN E-002 ELECTRICAL RENOVATION PLAN UNIVERSITY OF SOUTH CAROLINA GAMBRELL 153 AUDITORIUM M A R K D E S C R I P T I O N D A T E

Upload: others

Post on 03-May-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1 2 3 4 5 GAMBRELL 153 AUDITORIUM UNIVERSITY OF SOUTH …purchasing.sc.edu/solicitations/s_1579299873.pdf · 2020-01-17 · 133 sf 137 sf 137 sf 129 sf 137 sf 353 sf 596 sf 294 sf

N

LOCATION MAPSCALE: N.T.S.

1 2 3 4 5

A

B

C

D

SHEET OF

1301 Gervais Street, Suite 1300Columbia, SC 29201Phone (803) 799-6502www.pondco.com

SHEET ID

1301 G

erv

ais

Str

eet,

Suite 1

300

Colu

mbia

, S

C 2

9201

Phone (

803)

799-6

502

ww

w.p

ondco.c

om

SIZ

E:

AN

SI D

FIL

E N

AM

E:

SU

BM

ITT

ED

BY

:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

DE

SIG

NE

D B

Y:

ISS

UE

DA

TE

:

SO

LIC

ITA

TIO

N N

O.:

CO

NT

RA

CT

NO

.:

FIL

E N

UM

BE

R:

Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.

STAMP/SEAL

7 Clusters Court, Suite 201Columbia, SC 29210Phone (803) 731-0650www.bea-consulting.com

BELKA ENGINEERING ASSOCIATES, INC.

1/1

4/2

020

11:0

8:4

8 P

MC

:\U

se

rs\w

hite

l\D

ocum

en

ts\U

SC

Gam

bre

ll A

ud

itoriu

m_

Arc

h-I

_v1

9_

wh

itel2

6X

5B

.rvt

G-001

CONSTRUCTION DOCUMENTS

PROJ. NO.: H27-Z407 50003375-2CONSTRUCTION DOCUMENTS

15 JANUARY 2020

COLUMBIA, SOUTH CAROLINA

CO

VE

R S

HE

ET

GA

MB

RE

LL 1

53 A

UD

ITO

RIU

MU

NIV

ER

SIT

Y O

F S

OU

TH

CA

RO

LIN

AC

OLU

MB

IA,

SO

UT

H C

AR

OLIN

A

UN

IVE

RS

ITY

OF

SO

UT

H C

AR

OLIN

A

GA

MB

RE

LL H

ALL, 817 H

EN

DE

RS

ON

ST

RE

ET

CO

LU

MB

IA, S

OU

TH

CA

RO

LIN

A 2

9208

JO

B N

O.

1200321

LS

W

AH

LM

15 J

AN

UA

RY

2020

PR

OJ. N

O.: H

27-Z

407

50003375-2

PR

OJ.

NO

.: H

27-Z

407 5

0003375-2

PROJECT LOCATIONGAMBRELL HALL

SHEET INDEXSHEET

NUMBER SHEET NAME

GENERAL

G-001 COVER SHEET

LS-101 LIFE SAFETY PLAN

ARCHITECTURAL

A-001 GENERAL NOTES AND ABBREVIATIONS

A-002 PARTITION TYPES & DETAILS

AD101 DEMOLITION PLANS

A-101 RENOVATION PLANS

A-301 SECTION/ELEVATION & DETAILS

A-601 DOOR SCHEDULE & DETAILS

A-631 FINISH SCHEDULE & FURNITURE PLAN

ELECTRICAL

E-001 ELECTRICAL DEMOLITION PLAN

E-002 ELECTRICAL RENOVATION PLAN

UNIVERSITY OF SOUTH CAROLINAGAMBRELL 153 AUDITORIUM

MA

RK

DE

SC

RIP

TIO

ND

AT

E

whitel
Rectangle
whitel
Stamp
whitel
LSW Seal
Page 2: 1 2 3 4 5 GAMBRELL 153 AUDITORIUM UNIVERSITY OF SOUTH …purchasing.sc.edu/solicitations/s_1579299873.pdf · 2020-01-17 · 133 sf 137 sf 137 sf 129 sf 137 sf 353 sf 596 sf 294 sf

OPEN

TO

ABOVE

DOOR

TOLOWER

LEVELCORRIDOR

H012

DN

UP

DN

UP

UP

UP

DN UPDN

DN DN DN DN

DN

DN

207 SF

MEN244 SF

WOMEN312 SF

1403 SF

305 SF

187 SF

LOBBY2100 SF

MEN337 SF

WOMEN278 SF

396 SF

CUST.35 SF

394 SF

153 SF

156 SF

ELEC.68 SF

CUST.94 SF

ELEC./COMM.

67 SF

760 SF

530 SF

TRASH2 SF

750 SF

193 SF

561 SF

COMM.12 SF

COVEREDWALKWAY

3683 SF

54 SF 51 SF 52 SF

616 SF 714 SF

99 SF

2431 SF

53 SF

45 SF

1455 SF1458 SF

77 SF

263 SF

612 SF

410 SF

175 SF

397 SF

292 SF

393 SF

141 SF

137 SF413 SF

136 SF137 SF

137 SF136 SF136 SF208 SF

180 SF 146 SF

137 SF

134 SF

137 SF

357 SF596 SF 577 SF

133 SF

137 SF

137 SF

129 SF

137 SF353 SF

596 SF

294 SF

134 SF

137 SF

127 SF 115 SF

207 SF 135 SF 135 SF 136 SF 132 SF 136 SF 133 SF 136 SF

157 SF 157 SF130 SF

103A 103

ST05

157

158

159

153

153A

153C

H108

152151

H107

156

ST04

V103

V101

161162

H105

155

H104

ST03

150

101

ST01

165

166

102

173

148

H103

105

106

109

H106

107108

110113

115116118119

117 114

120

121

122

167

123

124 104

H101

126125

ST02

127128

131

130

129

149

132

133

137 140

H102

134 135 138 139 142 143 146 147

144 145

168

136

X101

EV01 EV02 EV03

103A 103

ST05

157

158159153

153A

153C

H108

152151

H107

156

ST04

V103

V101

161

162

H105

155

H104

ST03

150

101

ST01

165

166

102

173

148

H103

105

106

109

H106

107108

110113

115116118119

117 114

120

121

122

167

123124 104

H101

126

125

ST02 127

128

131130

129

149

132

133

137 140

H102

134 135 138 139 142 143 146 147

144 145

168

136

X101

EV01 EV02 EV03

GENERAL LIFE SAFETY SHEET NOTES:

1. DEVICES HAVE BEEN SHOWN; BUT THE CONTRACTOR SHALL ENSURE THE INSTALLATION OF ALL LIFE SAFETY DEVICES INDICATED ON THE ENGINEERING DRAWINGS.

2. CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF ANY EXISTING FIRE RATED WALLS. ANY WORK DONE AROUND EXISTING FIRE RATED WALLS SHALL BE DONE WITH CARE SO AS NOT TO COMPROMISE THE RATING'S INTEGRITY. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY.

3. CONTRACTORS SHALL FOLLOW EM-385-1-1 AND NFPA 241, ALONG WITH THE INSTALLATION’S FIRE REGULATIONS.

4. FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING. SUCH IDENTIFICATION SHALL:

a. BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL AND AT INTERVALS NOT EXCEEDING 30 FEET MEASURED HORIZONTALLY

ALONG WITH WALL OR PARTITION. b. INCLUDE LETTERING NOT LESS THAN 3 INCHES IN HEIGHT WITH A MINIMUM 3/8-INCH STROKE IN A CONTRASTING COLOR

INCORPORATING THE SUGGESTED WORDING, “FIRE AND/OR SMOKE BARRIER – PROTECT ALL OPENINGS,” OR OTHER WORDING

1-HR. RATED WALLS

LIFE SAFETY PLAN LEGEND

45'-0"TRAVEL DISTANCE

EXIT SIGN WITH DIRECTION ARROWS-SEE ELECT. DWGS.

EGRESS CLEAR WIDTHCAPACITY/NO. OF OCCUPANTS

2-HR. RATED WALLS

STARTING POINT FOR TRAVEL DISTANCE

36"100/100

48

' - 7"

CATCHMENT AREA FOR EXIT

84 SEATS

59'-0"

37'-8"

68"309/154

34"154/59

68"309/95

DEAD END

13' - 1"

CATCHMENT AREA FOR EXIT

56 SEATS

CATCHMENT AREA FOR EXIT

85 SEATS

CATCHMENT AREA FOR EXIT

57 SEATS

4' - 0"

2' - 11"

1/2 DIAGONAL DISTANCE = 30'-3"

1 2 3 4 5

A

B

C

D

SHEET OF

SHEET ID

1301 G

erv

ais

Str

eet,

Suite 1

300

Colu

mbia

, S

C 2

9201

Phone (

803)

799-6

502

ww

w.p

ondco.c

om

SIZ

E:

AN

SI D

FIL

E N

AM

E:

SU

BM

ITT

ED

BY

:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

DE

SIG

NE

D B

Y:

ISS

UE

DA

TE

:

SO

LIC

ITA

TIO

N N

O.:

CO

NT

RA

CT

NO

.:

FIL

E N

UM

BE

R:

Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.

STAMP/SEAL

1/1

4/2

020

11:0

8:4

9 P

MC

:\U

se

rs\w

hite

l\D

ocum

en

ts\U

SC

Gam

bre

ll A

ud

itoriu

m_

Arc

h-I

_v1

9_

wh

itel2

6X

5B

.rvt

LS-101

CONSTRUCTION DOCUMENTS

LIF

E S

AF

ET

Y P

LA

N

GA

MB

RE

LL 1

53 A

UD

ITO

RIU

MU

NIV

ER

SIT

Y O

F S

OU

TH

CA

RO

LIN

AC

OLU

MB

IA,

SO

UT

H C

AR

OLIN

A

UN

IVE

RS

ITY

OF

SO

UT

H C

AR

OLIN

A

GA

MB

RE

LL H

ALL, 817 H

EN

DE

RS

ON

ST

RE

ET

CO

LU

MB

IA, S

OU

TH

CA

RO

LIN

A 2

9208

JO

B N

O.

1200321

LS

W

LS

W

LM

15 J

AN

UA

RY

2020

PR

OJ. N

O.: H

27-Z

407

50003375-2

PR

OJ.

NO

.: H

27-Z

407 5

0003375-2

CODE REVIEW SUMMARY

PER IBC 2015, THE FOLLOWING ASSUMPTIONS WERE MADE BASED UPON EXISTING DRAWINGS DATED 6/21/1975:- BUILDING IS APPROXIMATELY 139,000 SF, TYPE IB CONSTRUCTION, 5-STORIES PLUS LOWER LEVEL, AND NON-SPRINKLERED.- BUILDING IS CLASSIFIED AS SEPARATED MIXED-USE WITH BUSINESS OCCUPANCY AND ASSEMBLY GROUP A-3-FIRE RESISTIVE RATINGS: IBC, TABLE 601; SECTION 602.2STRUCTURAL FRAME 2 HR.EXT. BEARING WALLS 2 HR.INT. BEARING WALLS 2 HR.INT. NON-BEARING WALLS AND PARTITIONS 0 HR.FLOOR CONSTRUCTION 2 HR.ROOF CONSTRUCTION 1 HR.CORRIDORS 1 HR.

-ALLOWABLE HEIGHT:ASSEMBLY (A-3) (MOST RESTRICTIVE), 160 FT/ 11 STORIES (AS PER IBC 504.3 & 504.4)

-ALLOWABLE AREA: ASSEMBLY (A-3) (MOST RESTRICTIVE), BASED ON IBC TABLE 506.2 - UNLIMITED SQUARE FEETEXIT REQUIRMENTS (PER NFPA 101 LSC):-2 MEANS OF EGRESS REQUIRED (13.2.4.2)-MINIMUM AISLE ACCESSWAY WIDTH BETWEEN ROWS OF SEATS IS 12" (13.2.5.5.2).-DEAD END AISLE MAX DISTANCE IS 20'-0" (13.2.5.6.2).-MINIMUM AISLE WIDTH: 42" FOR CATCHMENT AREAS GREATER THAN 60 SEATS, 30" FOR CATCHMENT AREAS LESS THAN 60 SEATS (13.2.5.6.3). -AISLE STAIR TREAD DEPTH NOT LESS THAN 11" (13.2.5.3.5), EXISTING DEPTH 18".-AISLE STAIR RISER HEIGHT NOT LESS THAN 3-1/2" (13.2.5.6.6), EXISTING HEIGHT 4".-AISLE HANDRAILS NOT REQUIRED WHERE RISERS ARE LESS THAN 7" IN HEIGHT (13.2.5.6.9.7).-CONTRASTING NOSING REQUIRED (13.2.5.6.10.1).-MAXIMUM TRAVEL DISTANCE TO EXIT IS 200' (13.2.6.1).

SCALE: 3/32" = 1'-0"A1LIFE SAFETY PLAN

SCALE: = 1'-0"3/32"

0 8 16 248

NORTH

WORK AREA PER IEBC 2015, RENOVATION ISCLASSIFIED AS AN "ALTERATION-LEVEL1"

MA

RK

DE

SC

RIP

TIO

ND

AT

E

whitel
Rectangle
whitel
Stamp
whitel
LSW Seal
Page 3: 1 2 3 4 5 GAMBRELL 153 AUDITORIUM UNIVERSITY OF SOUTH …purchasing.sc.edu/solicitations/s_1579299873.pdf · 2020-01-17 · 133 sf 137 sf 137 sf 129 sf 137 sf 353 sf 596 sf 294 sf

ARCHITECTURAL ABBREVIATIONS

CL

GENERAL NOTES:

SYMBOLS:

VIEW TITLES:

PLAN SYMBOLS:

MATERIALS IN SECTION - FILL PATTERNS:

A.F.A.F.F.ACC. DR.ADAAG

ACCESS.ADJ.ACOUST.A.B.ACTANOD.A.C.AL / ALUM.&LAPP.APPROX.ARCH.@AT / FPAVG.A.W.I.

B.H.M.I.

BM.BLKG.BD.BTM.BLDG.B.U.R.

CFCI

CH.CPT.CLG.CLG. HT.CTR.

C. TO C.C.T.CLR.C.O.CLOS.CO.COL.CONC.CORR.COTR

CMUCONF.CONST.CONT.CONTR.C.J.C.Y.

DET.DIA.DIM.DISP.DR.DN.D.S.DESC.DWG.

EA.ELEC.EL.E.W.C.E.R.D.E.P.ENGR.EQUIP.EQ.EXIST.EXP.E.J. (EXP. JT.)EXP. TO STRUCT.EXT.ETD

FAC.FDCFT.F.E.F.E.C.F.H.C.FIN.F.P.F.F.FLR.F.D.FLUOR.F.O.G.FTG.FDN.FV.

RAISED ACCESS FLOORRECEPTIONISTREFERENCEREINFORCEMENTREQUIREDREVISIONS / REVISEDROOF DRAINRIGHT HANDRIGHT HAND REVERSEROOMROUGH OPENINGRUBBER BASE

SEALED CONCRETESOLID CORE WOODSCHEDULESECTIONSEMI-GLOSS PAINTSERVICE SINKSHEET METALSIMILARSOUND TRANSMISSION CLASSSPECIFICATIONSPRAYED FIRE RESISTIVE MATERIALSQUARESTAINSTAINLESS STEELSTANDARDSTEELSTORAGESTRUCTURALSUSPENDED

TOILETTELEPHONETHICKTHRESHOLDTEMPERED GLASSTOP OFTOP OF BEAMTOP OF CONCRETETOP OF CURBTOP OF STEELTOP OF WALLTOUCH-UPTYPICAL

UNDERWRITERS LABORATORIESUNFINISHEDUNLESS NOTED OTHERWISE

VERTICALVESTIBULEVINYL COMPOSITION TILEVINYL COVE BASEVENT THRU ROOF

WIDTHWITHWATER CLOSETWALL CLEAN OUTWOODWINDOWWIRE MESH PARTITIONWITHOUTWATER RESISTANT GYPSUM BOARDWEATHERSTRIPPINGWINDOW ROUGH OPENING

YARD

SECTION NUMBER

DWG. NO. WHERE SECTION IS DRAWN

WALL SECTION MARK

SECTION NUMBER

DWG. NO. WHERE SECTION IS DRAWN

BUILDING SECTION MARK

ELEVATION NUMBER (TYP.)

DWG. NO. WHERE ELEVATION IS DRAWN

INTERIOR ELEVATION MARK

DWG. NO. WHERE DETAIL IS DRAWN

CALLOUT HEAD

DETAIL NUMBER (TYP.)

AREA COVERED BY DETAIL

DOOR TAG WINDOW & LOUVER TAG

ROOM TAG PARTITION TYPE

EARTH

CONCRETE / GROUT

SAND / E.I.F.S. / PLASTER / STUCCO

STEEL

MASONRY - CONCRETE BLOCK

MASONRY - BRICK

RIGID INSULATION

BATT INSULATION EXPOSED & FINISHED WOOD TRIM

GYPSUM / PLASTER

PLYWOOD

ACCESS FLOORINGABOVE FINISHED FLOORACCESS DOOR / PANELAMERICAN WITH DISABILITIES ACCESSIBILITY GUIDELINESACCESSORIESADJUST/ ADJUSTABLEACOUSTICALANCHOR BOLTACOUSTICAL CEILING TILEANODIZEDAIR CONDITIONINGALUMINUMANDANGLEAPPROVEDAPPROXIMATEARCHITECTURALATANTI TERRORISM / FORCE PROTECTIONAVERAGEARCHITECTURAL WOODWORK INSTITUTE

BUILDER'S HARDWARE MANUFACTURER'S ASSOCIATION, INC.BEAMBLOCKINGBOARDBOTTOMBUILDINGBUILT-UP ROOFING

CONTRACTOR FURNISHED CONTRACTOR INSTALLEDCHANNELCARPETCEILINGCEILING HEIGHTCENTERCENTER LINECENTER TO CENTERCERAMIC TILECLEARCLEANOUTCLOSETCOMPANYCOLUMNCONCRETECORRIDORCONTRACTING OFFICER'S TECHNICAL REPRESENTATIVECONCRETE MASONRY UNITCONFERENCECONSTRUCTIONCONTINUOUSCONTRACTORCONTROL JOINTCUBIC YARD

DETAILDIAMETERDIMENSIONDISPENSERDOORDOWNDOWNSPOUTDESCRIPTIONDRAWING

EACHELECTRICAL OR ELECTRICELEVATIONELECTRIC WATER COOLEREMERGENCY ROOF DRAINEPOXY PAINTENGINEEREQUIPMENTEQUALEXISTINGEXPANSION / EXPOSEDEXPANSION JOINTEXPOSED TO STRUCTUREEXTERIORESTIMATED TRAVEL DISTANCE

FACTORYFIRE DEPARTMENT CONNECTIONFEETFIRE EXTINGUISHERFIRE EXTINGUISHER CABINETFIRE HOSE CABINETFINISHFLAT PAINTFINISHED FLOORFLOORFLOOR DRAINFLUORESCENTFACE OF GIRTFOOTINGFOUNDATIONFIELD VERIFY

RAFRECEP.REF.REINF.REQ'D.REV.R.D.RHRHRRM.R.O.RB

SCSCWSCHED.SECT.S.G.P.SSKSHT. MET.SIM.STCSPEC(S)SFRM

SQ.ST.S.S.STD.STL.STOR.STRUCT.SUSP.

TOIL. / TLTTEL.THK.T'HOLDTGT/TOBTOCT/CTOST/WTUTYP.

U.L.UNFINU.N.O.

VERT.VEST.VCTVCBV.T.R.

W.W/W.C.WCOWD.WDW.W.M.P.W/OW.R.G.B.

W.S.W.R.O.

YD.

GRAVEL

KEYNOTE TAG

CEILING TAG(HEIGHT)

CEILING TAG(TYPE & HEIGHT)

CEILING HGT.

CEILING TYPESUBSCRIPT TYPE (AS REQ)

PARTITION TYPE

EQUIPMENT TAG

GA.GALV.G.B.F.GFCI

GFGI

G.L.G.P.GL.GOVT.GYP.GYP. BD. (GWB)

HKSHR.HDW.HGT.H.H.P.H.M.HORIZ.HBH.V.A.C.

IN.I.D.INSUL.INT.

JAN.J.C.JT.JST.

K.P.

LAM.LDG.LAV.L.H.LHRLT.LTG.LONG.LVR.L.P.

MAS.M.O.MGR.MANUF.MATL.MAX.MECH.MTL.M.W.P.MIN.MISC.

N.I.C.NO. (#)NTSNFPA

O.C.OFCI

OFGI

O.H.OPNG.O.W.OPP.O.D.OSHA

OVHD

PDUPTPR.PNL.PART.PLAS.PLPLYWD.LBS. OR #PSFPSIP.M.J.F.PRE-FAB.

Q.T.

1. THE DRAWINGS INDICATE THE GENERAL EXTENT OF WORK. THE DRAWINGS ARE NOT INTENDED TO INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.

2. THE ENUMERATION OF PARTICULAR ITEMS OF WORK IN ONE PORTION OF THE CONTRACT DOCUMENTS SHALL NOT BE CONSTRUED TO EXCLUDE OTHER ITEMS NECESSARY OR IMPLIED THEREFROM.

3. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PARTS OF THE WORK SO THAT NO WORK SHALL BE LEFT IN AN UNFINISHED OR INCOMPLETE CONDITION.

4. ALL WORK SHALL CONFORM TO APPLICABLE INDUSTRY AND MANUFACTURER'S PUBLISHED STANDARDS FOR QUALITY OF MATERIALS AND WORKMANSHIP, AS WELL AS, ALL REQUIREMENTS IN THESE DRAWINGS AND SPECIFICATIONS. ANY CONFLICTING REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION PRIOR TO PROCEEDING WITH THE WORK.

5. THE CONTRACTOR SHALL PROTECT ANY EXISTING, IN-PLACE, AND NEW WORK.

6. ALL WORK NOTED "N.I.C." IS NOT MEANT TO BE PART OF THE CONSTRUCTION SCOPE OF WORK AGREEMENT.

7. THE CONTRACTOR SHALL PAY FOR AND COORDINATE THE REMOVAL AND LEGAL DISPOSAL OF MATERIALS AND RUBBISH.

8. ONCE ON SITE, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SHALL VERIFY ALL NEW AND EXISTING CONDITIONS, SHOWN ON THESE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING OF ANY DIFFERING CONDITIONS BEFORE COMMENCEMENT OF WORK.

9. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN, LARGE SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING OF ANY DIFFERING CONDITIONS BEFORE COMMENCEMENT OF WORK.

10. UNLESS NOTED OTHERWISE, ALL GYPSUM BOARD SURFACES ARE TO RECEIVE ONE PRIMER COAT AND TWO COATS OF PAINT.

11. DIMENSIONS NOTED AS 'HOLD' SHALL NOT VARY BY MORE THAN 1/8" FROM SIDE TO SIDE OR FROM FRONT TO BACK, FINISHED SURFACE TO FINISHED SURFACE.

12. NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, AND ALTERATION OPERATIONS SHALL BE APPLIED.

13. WALL AND/OR CEILING ASSEMBLIES THAT ARE IDENTIFIED WITH A FIRE RESISTIVE RATING SHALL BE CONSTRUCTED AS DETAILED HEREIN.

14. DIMENSIONS SHOWN ARE TO FACE OF STUD OR CMU (U.N.O.).15. PROVIDE EXPANSION AND CONTROL JOINTS IN ALL WORK AS PER

PRODUCT MANUFACTURER'S STANDARDS. 16. THE CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH

ALL APPLICABLE CODES, ORDINANCES AND REGULATORY AGENCIES AND SHALL OBTAIN NECESSARY BUILDING AND FIRE PERMITS FROM ALL AUTHORITIES HAVING JURISDICTION.

17. ALL INTERIOR FINISH MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE CODES, ORDINANCES AND REGULATORY AGENCIES.

18. ALL DISSIMILAR METALS SHALL BE ISOLATED FROM EACH OTHER TO AVOID GALVANIC CORROSION.

19. NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND MATERIALS. SHEETS ARE TO BE REVIEWED AND NOTES ON INDIVIDUAL SHEETS SHALL BE APPLIED TO RELATED DRAWINGS AND DETAILS.

20. A FINISH INDICATION ON A WALL SHALL MEAN THE ENTIRE LENGTH AND HEIGHT OF WALL IS TO BE FINISHED OR FIRE-RATED AS INDICATED.

21. WHEN NON-DIMENSIONED PARTITIONS APPEAR IN CONJUNCTION WITH DOOR OPENINGS, THE DOOR WIDTH AND THE DOOR FRAME DETAILS DETERMINE THE LOCATION OF ADJACENT WALLS AND FRAMES.

22. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE DETAILED. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.

23. THE CONTRACTOR SHALL COORDINATE ALL ELECTRICAL FLOOR AND WALL SLEEVES INCLUDING CONDUITS WITH ALL ELECTRICAL AND ARCHITECTURAL DRAWINGS.

24. ALL PIPE DUCTS AND BUS DUCTS THAT PENETRATE FLOOR SLABS OR WALL PARTITIONS SHALL BE INSTALLED IN A MANNER THAT WILL PRESERVE THE MOISTURE RESISTIVENESS, FIRE RATING, AND STRUCTURAL INTEGRITY OF THE BUILDING.

25. INTERIOR PARTITION MOVEMENT CONTROL:A. VERTICAL CONTROL JOINTS FOR ANY WALL LENGTH ARE TO OCCUR

AT NOT MORE THAN 30'-0" O.C. IN THE HORIZONTAL DIRECTION, UNLESS NOTED OTHERWISE.

B. PROVISIONS SHALL BE MADE IN THE DESIGN, FABRICATION, AND INSTALLATION OF INTERIOR PARTIONS FOR TYPICAL FLOOR DEFLECTIONS OF THE STRUCTURE UNDER SUPERIMPOSED LOADS AS FOLLOWS:

a. TYPICAL ROOF/FLOOR MEMBERS: SPAN/360 BUT NOT LESS THAN 1/2”.

26. THE CONTRACTOR SHALL PLAN HIS/HER WORK TO PROVIDE ADEQUATE PROTECTION FOR PERSONS AND PROPERTY AT ALL TIMES, AND EXECUTE THE WORK IN SUCH A MANNER TO AVOID ANY HAZARD TO PERSONS AND PROPERTY AS NECESSARY.

27. THE CONTRACTOR SHALL COORDINATE THE PHASING OF THE WORK TO BE PERFORMED IN OR ABOUT EXISTING FACILITIES, IF APPLICABLE, WITH THE OWNER'S REPRESENTATIVE PRIOR TO START OF SUCH WORK. THE WORK IS INTENDED TO BE COMPLETED OVER THE SUMMER . CONTRACTOR IS RESPONSIBLE FOR SECURING THE SPACE AND DUST CONTROL.

GAGE OR GAUGEGALVANIZEDGYPSUM BOARD FURRINGGOVERNMENT FURNISHED CONTRACTOR INSTALLEDGOVERNMENT FURNISHED GOVERNMENT INSTALLEDGIRT LINEGLOSSY PAINTGLASSGOVERNMENTGYPSUMGYPSUM BOARD

HOOKSHANDRAILHARDWAREHEIGHTHIGHHIGH POINTHOLLOW METALHORIZONTALHOSE BIBBHEATING VENTILATION & AIR CONDITIONING

INCHINSIDE DIAMETERINSULATIONINTERIOR

JANITORJANITOR'S CLOSETJOINTJOIST

KICK PLATE

LAMINATELANDINGLAVATORYLEFT HANDLEFT HAND REVERSELIGHTLIGHTINGLONGITUDINALLOUVERLOW POINT

MASONRYMASONRY OPENINGMANAGERMANUFACTURERMATERIALMAXIMUMMECHANICALMETALMETAL WALL PANELMINIMUMMISCELLANEOUS

NOT IN CONTRACTNUMBERNOT TO SCALENATIONAL FIRE PROTECTION ASSOCIATION

ON CENTEROWNER FURNISHED CONTRACTOR INSTALLEDOWNER FURNISHED GOVERNMENT INSTALLEDOPPOSITE HANDOPENINGOPEN WEBOPPOSITEOUTSIDE DIAMETEROCCUPATIONAL SAFETY AND HEALTH ACTOVERHEAD

POWER DISTRIBUTION UNITPAINTPAIRPANELPARTITIONPLASTER OR PLASTICPLATEPLYWOODPOUNDSPOUNDS / SQUARE FOOTPOUNDS / SQUARE INCHPRE-MOLDED JOINT FILLERPREFABRICATED

QUARRY TILE

DETAIL IDENTIFIER (MODULE LETTER AND NUMBER)

NORTH ARROWS

FLOOR PLANS, ELEVATIONS OR DETAIL VIEWS TITLE

A-101

1SIM

A-101

ROOM NAME101

A101 12'-0" A.F.F. 1t 12'-0" A.F.F.A1-X 1i

N

A1ELEVATIONS, DETAILS & CALLOUTSSCALE: 1/8" = 1'-0"

A101

1

EXTERIOR ELEVATION MARK

ELEVATION NUMBER (TYP.)

DWG. NO. WHERE ELEVATION IS DRAWN

REVISION TAG

1

1

1

1

1

N

NCS AEC

DEMOLITION KEYNOTE TAG

(NAVFAC)

TRUE NORTH

TRUE NORTH

DETAIL NUMBER

DWG. NO. WHERE SECTION IS DRAWN

DETAIL SECTION MARK

A1

A-101

SIMA1

A-101

SIMA1

A-101

SIMA1

A-101

SIM

# #

1 2 3 4 5

A

B

C

D

SHEET OF

SHEET ID

1301 G

erv

ais

Str

eet,

Suite 1

300

Colu

mbia

, S

C 2

9201

Phone (

803)

799-6

502

ww

w.p

ondco.c

om

SIZ

E:

AN

SI D

FIL

E N

AM

E:

SU

BM

ITT

ED

BY

:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

DE

SIG

NE

D B

Y:

ISS

UE

DA

TE

:

SO

LIC

ITA

TIO

N N

O.:

CO

NT

RA

CT

NO

.:

FIL

E N

UM

BE

R:

Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.

STAMP/SEAL

1/1

4/2

020

11:0

8:4

5 P

MC

:\U

se

rs\w

hite

l\D

ocum

en

ts\U

SC

Gam

bre

ll A

ud

itoriu

m_

Arc

h-I

_v1

9_

wh

itel2

6X

5B

.rvt

A-001

CONSTRUCTION DOCUMENTS

GE

NE

RA

L N

OT

ES

AN

D A

BB

RE

VIA

TIO

NS

GA

MB

RE

LL 1

53 A

UD

ITO

RIU

MU

NIV

ER

SIT

Y O

F S

OU

TH

CA

RO

LIN

AC

OLU

MB

IA,

SO

UT

H C

AR

OLIN

A

UN

IVE

RS

ITY

OF

SO

UT

H C

AR

OLIN

A

GA

MB

RE

LL H

ALL, 817 H

EN

DE

RS

ON

ST

RE

ET

CO

LU

MB

IA, S

OU

TH

CA

RO

LIN

A 2

9208

JO

B N

O.

1200321

LS

W

LS

W

LM

15 J

AN

UA

RY

2020

PR

OJ. N

O.: H

27-Z

407

50003375-2

PR

OJ.

NO

.: H

27-Z

407 5

0003375-2

MA

RK

DE

SC

RIP

TIO

ND

AT

E

whitel
Rectangle
whitel
Stamp
whitel
LSW Seal
Page 4: 1 2 3 4 5 GAMBRELL 153 AUDITORIUM UNIVERSITY OF SOUTH …purchasing.sc.edu/solicitations/s_1579299873.pdf · 2020-01-17 · 133 sf 137 sf 137 sf 129 sf 137 sf 353 sf 596 sf 294 sf

INTERIOR PARTITION GENERAL NOTES

1. PARTITION TYPES DESCRIBE GENERAL REQUIREMENTS FOR PARTITIONS. REFER TO THE MANUFACTURER'S SPECIFICATIONS AND REQUIREMENTS OF APPLICABLE TESTING AGENCIES FOR SPECIFICS OF PARTITION CONSTRUCTION.

2. REFER TO "PARTITION TYPE NOMENCLATURE" FOR SYMBOLS USED TO IDENTIFY ADDITIONAL REQUIREMENTS AND MODIFIERS TO BASIC PARTITION TYPES.

3. "LINE OF STRUCTURE" INDICATED FOR EACH PARTITION IS DIAGRAMMATIC ONLY AND DOES NOT INDICATE EXACT CONSTRUCTION CONDITIONS OR GEOMETRY.

4. TYPICAL FLOOR PLAN DIMENSIONS OF PARTITIONS ARE TO FACE OF STUD OR CMU UNLESS NOTED OTHERWISE.

5. WHERE A CLEAR OPENING DIMENSION IS INDICATED, THE DIMENSION IS MEASURED FACE-TO-FACE BETWEEN FINISHED SURFACES.

6. REFER TO SPECIFICATIONS FOR MINIMUM STUD DESIGN CRITERIA, MAXIMUM SPACING AND ALLOWABLE LIMITING HEIGHTS DEFLECTION CRITERIA FOR GYPSUM BOARD.

7. METAL STUD GAUGE (IF NOTED) AND UL TEST NUMBERS WILL VARY DEPENDING ON THE MANUFACTURER OF COMPONENTS ACTUALLY USED.

8. REFER TO FLOOR PLANS FOR FIRE PROTECTION RATINGS.

9. ALL RATED PARTITIONS SHALL BE LABELED ABOVE CEILING WITH LABELS PER AHJ AS REQUIRED. IBC CHAPTER 7 AT MINIMUM.

10. PENETRATIONS IN RATED PARTITIONS AND CONNECTIONS OF THE PARTITIONS TO OTHER PORTIONS OF THE WORK TO BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED DETAILS AND IN COMPLIANCE WITH APPLICABLE TESTING AGENCY REQUIREMENTS.

11. INSTALLATION OF GYPSUM BOARD, BACKER BOARD AND BASE BOARD TO CONFORM TO REQUIREMENTS FOR FIRE RATINGS AND ACOUSTICAL RATINGS.

12. PROVIDE WATER RESISTANT TYPE GYPSUM BOARD AT AREAS THAT ARE NOTED IN ROOM FINISH SCHEDULE TO RECEIVE CERAMIC OR PORCELAIN TILE FINISH.

13. INSTALL BLOCKING OR BACKER MATERIAL FOR ATTACHMENT / MOUNTING OF WALL HUNG ITEMS OR EQUIPMENT DESCRIBED IN THE DOCUMENTS. ALL BLOCKING TO BE FIRE RETARDANT TREATED.

14. PARTITIONS THAT ARE REQUIRED TO EXTEND TO THE DECK ABOVE ARE TO HAVE THE GYPSUM BOARD CUT TO FIT WITHIN A 1/4" MAXIMUM TOLERANCE TO THE SHAPE OF THE DECK ABOVE. GYPSUM BOARD SHALL BE CONTINUOUSLY SEALED FOR THE FULL DEPTH OF THE GYPSUM BOARD WITH FLEXIBLE SEALANT.

15. PROVIDE METAL STRAPPING @ 24" VERT. TO HOLD BATT INSULATION FOR AREAS WITHOUT GYPSUM WALLBOARD.

16. GYPSUM BOARD IS TO BE CUT SO THAT THE CLEARANCE BETWEEN METALLIC ELECTRICAL OUTLET BOXES AND THE GYPSUM BOARD DOES NOT EXCEED 1/8".

17. THE BOTTOM OF THE GYPSUM BOARD AT INTERIOR PARTITIONS IS TO BE 1/4" MINIMUM AND 1/2" MAXIMUM ABOVE THE FLOOR STRUCTURE AND IS TO BE SEALED FOR THE FULL DEPTH OF THE GYPSUM BOARD WITH FLEXIBLE SEALANT.

18. REFER TO INTERIOR FINISH SCHEDULE FOR WALL FINISHES.

19. REFER TO PARTITION TYPE MODIFIERS FOR STC RATED PARTITIONS

CAULKLINE OF FLOOR STRUCTURE

METAL RUNNER

GYPSUM BOARD

REFER TO FURRING STUD SCHEDULE BELOW FOR PARTITION WIDTH

WIDTH

PL

AN

BRACE EACH STUD AT 4'-0" OC VERTICALLY

METAL RUNNER

LINE OF CEILING

HE

AD

BA

SE

PARTITION TYPE F

FURRING STUD SCHEDULE

MARKSTUDWIDTH

GWBLAYERS

PARTITIONWIDTH

FIRERATING UL LISTING

F 3-5/8" (1) 5/8" 4 1/4" 0 HR N/A

1 2 3 4 5

A

B

C

D

SHEET OF

SHEET ID

1301 G

erv

ais

Str

eet,

Suite 1

300

Colu

mbia

, S

C 2

9201

Phone (

803)

799-6

502

ww

w.p

ondco.c

om

SIZ

E:

AN

SI D

FIL

E N

AM

E:

SU

BM

ITT

ED

BY

:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

DE

SIG

NE

D B

Y:

ISS

UE

DA

TE

:

SO

LIC

ITA

TIO

N N

O.:

CO

NT

RA

CT

NO

.:

FIL

E N

UM

BE

R:

Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.

STAMP/SEAL

1/1

4/2

020

11:0

8:4

6 P

MC

:\U

se

rs\w

hite

l\D

ocum

en

ts\U

SC

Gam

bre

ll A

ud

itoriu

m_

Arc

h-I

_v1

9_

wh

itel2

6X

5B

.rvt

A-002

CONSTRUCTION DOCUMENTS

PA

RT

ITIO

N T

YP

ES

& D

ET

AIL

S

GA

MB

RE

LL 1

53 A

UD

ITO

RIU

MU

NIV

ER

SIT

Y O

F S

OU

TH

CA

RO

LIN

AC

OLU

MB

IA,

SO

UT

H C

AR

OLIN

A

UN

IVE

RS

ITY

OF

SO

UT

H C

AR

OLIN

A

GA

MB

RE

LL H

ALL, 817 H

EN

DE

RS

ON

ST

RE

ET

CO

LU

MB

IA, S

OU

TH

CA

RO

LIN

A 2

9208

JO

B N

O.

1200321

LS

W

AH

LM

15 J

AN

UA

RY

2020

PR

OJ. N

O.: H

27-Z

407

50003375-2

PR

OJ.

NO

.: H

27-Z

407 5

0003375-2

MA

RK

DE

SC

RIP

TIO

ND

AT

E

whitel
Rectangle
whitel
Stamp
whitel
LSW Seal
Page 5: 1 2 3 4 5 GAMBRELL 153 AUDITORIUM UNIVERSITY OF SOUTH …purchasing.sc.edu/solicitations/s_1579299873.pdf · 2020-01-17 · 133 sf 137 sf 137 sf 129 sf 137 sf 353 sf 596 sf 294 sf

UP

DN DN

DN

207 SF

MEN244 SF

WOMEN312 SF

1403 SF

99 SF

2431 SF

53 SF

45 SF

77 SF

263 SF

ST05

157

158

159

153

153A

153C

H108

152151

V103

ST05

157

158159153

153A

153C

H108

156

V103

207 SF

MEN244 SF

WOMEN312 SF

1403 SF

99 SF

53 SF

45 SF

77 SF

263 SF

ST05

ST05

157

158159

153A

153C

H108

156

V103

DEMOLITION PLAN LEGEND

EXISTING WALL PARTITIONS TO REMAIN

ITEMS TO BE REMOVED

EXISTING DOOR, FRAME AND ACCESSORIES TO REMAINUNLESS NOTED OTHERWISE

N.I.C.

1. SEE SHEET A-001 FOR GENERAL NOTES. 2. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL

INFORMATION.3. WHILE WORK UNDER THIS CONTRACT IS IN PROCESS,

PROTECT EXISTING BUILDING, GROUNDS AND CONTENTS INCLUDING ADJACENT AREAS FROM DAMAGE OR HARM.

4. ALL DEMOLITION MATERIAL, EQUIPMENT AND DEBRIS SHALL BE REMOVED FROM THE SITE TO AN AREA DESIGNATED BY THE OWNER'S REPRESENTATIVE.

5. THE CONTRACTOR SHALL REVIEW INSTALLATION DRAWINGS FOR NEW MATERIALS AND BE FAMILIAR WITH LIMITS OF DEMOLITION. THE CONTRACTOR SHALL KNOW AND UNDERSTAND NEW MATERIAL INSTALLATION IN AREAS WHERE EXISTING MATERIALS ARE REMOVED.

6. PROVIDE TEMPORARY SHELTER OR PORTALS AT ENTRANCES AND EXIT DOORS AS MAY BE REQUIRED FOR PROTECTION FROM FALLING DEBRIS OR OPEN TRENCHES. TEMPORARY PORTALS AND WALKWAYS ARE TO MEET ALL CODE REQUIREMENTS FOR WIDTH AND WALKING SURFACE CONTINUITY.

7. REPORT DATED 12/17/2019 PROVIDED BY THE UNIVERSITY OF SOUTH CAROLINA STATES THAT ROOM WAS TESTED AND FOUND TO BE FREE OF ASBESTOS CONTAINING MATERIALS.

8. FIRESTOP ALL PENETRATIONS OF SMOKE/FIRE PARTITIONS. FIRESTOPPING SHALL BE OF UL LISTED ASSEMBLY. THIS INCLUDES EXISTING PENETRATIONS THROUGH BARRIERS AND OPENINGS DUT TO SCOPE OF DEMO WORK ON THIS PROJECT. REFER TO LIFE SAFETY PLAN SHEET G-101 FOR RATED WALLS.

9. MAINTAIN AND PROTECT ALL SURFACES AND ITEMS TO REMAIN. SURFACES DAMAGED SHALL BE REPAIRED OR REPLACED TO LIKE NEW CONDITIONS.

DEMOLITION PLAN SHEET NOTES:KEYNOTES:

(KEYNOTE NUMBERS ARE UNIFORM ACROSS ALL SHEETS AND SOME MAY NOT BE REQUIRED ON THIS SHEET)

1

2

3

4 4

5

DOOR TO LOWER LEVEL CORRIDOR H012

6

7

9

8

11

153D

153B

16

10

11

N.I.C. (TYP)

12

13

14

15

N.I.C. (TYP)

1 2 3 4 5

A

B

C

D

SHEET OF

SHEET ID

1301 G

erv

ais

Str

eet,

Suite 1

300

Colu

mbia

, S

C 2

9201

Phone (

803)

799-6

502

ww

w.p

ondco.c

om

SIZ

E:

AN

SI D

FIL

E N

AM

E:

SU

BM

ITT

ED

BY

:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

DE

SIG

NE

D B

Y:

ISS

UE

DA

TE

:

SO

LIC

ITA

TIO

N N

O.:

CO

NT

RA

CT

NO

.:

FIL

E N

UM

BE

R:

Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.

STAMP/SEAL

1/1

4/2

020

11:0

8:4

8 P

MC

:\U

se

rs\w

hite

l\D

ocum

en

ts\U

SC

Gam

bre

ll A

ud

itoriu

m_

Arc

h-I

_v1

9_

wh

itel2

6X

5B

.rvt

AD101

CONSTRUCTION DOCUMENTS

DE

MO

LIT

ION

PLA

NS

GA

MB

RE

LL 1

53 A

UD

ITO

RIU

MU

NIV

ER

SIT

Y O

F S

OU

TH

CA

RO

LIN

AC

OLU

MB

IA,

SO

UT

H C

AR

OLIN

A

UN

IVE

RS

ITY

OF

SO

UT

H C

AR

OLIN

A

GA

MB

RE

LL H

ALL, 817 H

EN

DE

RS

ON

ST

RE

ET

CO

LU

MB

IA, S

OU

TH

CA

RO

LIN

A 2

9208

JO

B N

O.

1200321

LS

W

AH

LM

15 J

AN

UA

RY

2020

PR

OJ. N

O.: H

27-Z

407

50003375-2

PR

OJ.

NO

.: H

27-Z

407 5

0003375-2

SCALE: 1/8" = 1'-0"A1DEMOLITION PLAN

SCALE: 1/8" = 1'-0"A3REFLECTED CEILING PLAN - DEMOLITION

NORTH NORTH

SCALE: = 1'-0"

0 8 168

1/8"

KEYNOTE LEGEND DEMOLITION PLANS

KEY# KEYNOTE DESCRIPTION

1 REMOVE AND DISPOSE OF ALL EXISTING SEATING AND STUDENT DESKSLOCATED IN AUDITORIUM 153 OF GAMBRELL HALL. PATCH THE EXISTINGCONCRETE TIERS (AS REQUIRED).

2 REMOVE ALL EXISTING STAIR NOSINGS AND CARPETING TO BARESUBSTRATE (TYP. THROUGHOUT ROOM), INCLUDING FACES OF RISERSAND STAGE. REMOVE ALL EXISTING WALL BASE IN ITS ENTIRETY (TYP.THROUGHOUT ROOM).

3 REMOVE EXISTING AV CABINET AND COMPONENTS. EXISTING AVCONDUITS AND POWER SHALL BE REUSED AS IS. ENCLOSE ABANDONEDAV CABINET AREA WITH NEW 3 5/8" METAL STUDS AT 16" 0.C. AND 1LAYER OF 5/8" GYPSUM WALLBOARD.

4 REFURBISH EXISTING DOORS. SEE SHEET A-601.

5 UNIVERSITY OF SOUTH CAROLINA TO REMOVE EXISTING LECTERN ANDCOORDINATE THE LOCATION OF THE NEW LECTERN WITH UNIVERSITYOF SOUTH CAROLINA.

6 REMOVE AND REPLACE EXISTING DOOR HARDWARE.

7 EXISTING PROJECTION SCREEN TO BE ABANDONED IN PLACE. POWERSHALL BE DISCONNECTED AND RECONNECTED (D/R). COORDINATE WITHELECTRICAL DRAWINGS.

8 REMOVE AND REPLACE EXISTING AISLE LIGHTING. RETAIN ELECTRICALPOWER FOR NEW AISLE LIGHTS. COORDINATE WITH UNIVERSITY OFSOUTH CAROLINA DURING CONSTRUCTION.

9 REMOVE AND REPLACE EXISTING OUTLET COVERS.

10 REMOVE EXISTING "COLLEGE OF ARTS AND SCIENCES" LOGO FROMWALL. PATCH AND PAINT WALL.

11 REMOVE AND REPLACE EXISTING EXIT LIGHTS.

12 REMOVE AND REPLACE EXISTING GRILLE CLOTH FABRIC OVER EXISTINGSPEAKERS WITH NEW ALTERNATE #1

13 EXISTING PENDANT FIXTURES SHALL BE RELAMPED BY USC FACILITIESDURING CONSTRUCTION, AFTER THE EXISTING SEATS HAVE BEENREMOVED. CONTRACTOR SHALL COORDINATE WITH USC DURINGCONSTRUCTION.

14 EXISTING DOWNLIGHTS SHALL BE CHANGED OUT TO DIMMABLE LEDWITH SEVERAL CIRUCUITED WITH GENERATOR-BACKED CIRCUIT FOREMERGENCY EGRESS PURPOSES. SEE ELECTRICAL.

15 EXISTING ACOUSTICAL PANELS OVER STAGE SHALL BE REMOVED ANDREPLACED WITH NEW.

16 REMOVE EXISTING WOOD BLOCK MOUNT FOR FORMER PENCILSHARPENER

MA

RK

DE

SC

RIP

TIO

ND

AT

E

whitel
Rectangle
whitel
Stamp
whitel
LSW Seal
Page 6: 1 2 3 4 5 GAMBRELL 153 AUDITORIUM UNIVERSITY OF SOUTH …purchasing.sc.edu/solicitations/s_1579299873.pdf · 2020-01-17 · 133 sf 137 sf 137 sf 129 sf 137 sf 353 sf 596 sf 294 sf

UP

DN DN

DN

207 SF

MEN

244 SF

WOMEN

312 SF

1403 SF

99 SF

2431 SF

53 SF

45 SF

77 SF

263 SF

ST05

157

158

159

153

153A

153C

H108

152151

V103

ST05

157

158159153

153A

153C

H108

156

V103

207 SF

MEN

244 SF

WOMEN

312 SF

1403 SF

99 SF

53 SF

45 SF

77 SF

263 SF

ST05

ST05

157

158159

153A

153C

H108

V103

1. PARTITIONS SHALL BE TYPE "F" (NO SUBSCRIPT) UNLESS OTHERWISE INDICATED.

2. SEE SHEET A-001 FOR GENERAL NOTES.3. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL

INFORMATION.4. WHILE WORK UNDER THIS CONTRACT IS IN PROCESS,

PROTECT EXISTING BUILDING, GROUNDS AND CONTENTS INCLUDING ADJACENT AREAS FROM DAMAGE OR HARM.

5. ALL WASTE MATERIAL, EQUIPMENT AND DEBRIS SHALL BE REMOVED FROM THE SITE TO AN AREA DESIGNATED BY THE OWNER'S REPRESENTATIVE.

6. THE CONTRACTOR SHALL REVIEW DEMOLITION DRAWINGS FOR REMOVED MATERIALS AND BE FAMILIAR WITH LIMITS OF DEMOLITION. THE CONTRACTOR SHALL KNOW AND UNDERSTAND NEW MATERIAL INSTALLATION IN AREAS WHERE EXISTING MATERIALS ARE REMOVED.

7. PROVIDE TEMPORARY SHELTER OR PORTALS AT ENTRANCES AND EXIT DOORS AS MAY BE REQUIRED FOR PROTECTION FROM FALLING DEBRIS OR OPEN TRENCHES. TEMPORARY PORTALS AND WALKWAYS ARE TO MEET ALL CODE REQUIREMENTS FOR WIDTH AND WALKING SURFACE CONTINUITY.

8. REPORT DATED 12/17/2019 PROVIDED BY UNIVERSITY OF SOUTH CAROLINA STATES THAT ROOM WAS TESTED AND FOUND TO BE FREE OF ASBESTOS CONTAINING MATERIALS.

9. DIMENSIONS OF EXTERIOR WALLS ARE TO FACE OF WALL FINISH U.N.O.

10. DOORS INDICATED WITH ####. SEE SHEET A-601 FOR DOOR SCHEDULE & TYPES.

11. KEYNOTES INDICATED WITH .12. NEW FINISHES SHALL BE SELECTED BY USC.13. COORDINATE WITH BELKA FOR ELECTRICAL.14. COORDINATE WITH USC FOR AV.

FLOOR PLAN NOTES:

F

1

2

3

DOOR TO LOWER LEVEL CORRIDOR H012

4

153D

153B

5

6

A2

A-30113 13

14

15

B1

A-301

TYP.

N.I.C. (TYP)

WALL LEGENDEXISTING WALLPARTITION TO REMAIN

NEW WALL PARTITION

KEYNOTES:

(KEYNOTE NUMBERS ARE UNIFORM ACROSS ALL SHEETS AND SOME MAY NOT BE REQUIRED ON THIS SHEET)

7

8

9

1011

11

11

12

N.I.C.

1 2 3 4 5

A

B

C

D

SHEET OF

SHEET ID

1301 G

erv

ais

Str

eet,

Suite 1

300

Colu

mbia

, S

C 2

9201

Phone (

803)

799-6

502

ww

w.p

ondco.c

om

SIZ

E:

AN

SI D

FIL

E N

AM

E:

SU

BM

ITT

ED

BY

:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

DE

SIG

NE

D B

Y:

ISS

UE

DA

TE

:

SO

LIC

ITA

TIO

N N

O.:

CO

NT

RA

CT

NO

.:

FIL

E N

UM

BE

R:

Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.

STAMP/SEAL

1/1

6/2

020

12:4

9:3

3 P

MC

:\U

se

rs\w

hite

l\D

ocum

en

ts\U

SC

Gam

bre

ll A

ud

itoriu

m_

Arc

h-I

_v1

9_

wh

itel2

6X

5B

.rvt

A-101

CONSTRUCTION DOCUMENTS

RE

NO

VA

TIO

N P

LA

NS

GA

MB

RE

LL 1

53 A

UD

ITO

RIU

MU

NIV

ER

SIT

Y O

F S

OU

TH

CA

RO

LIN

AC

OLU

MB

IA,

SO

UT

H C

AR

OLIN

A

UN

IVE

RS

ITY

OF

SO

UT

H C

AR

OLIN

A

GA

MB

RE

LL H

ALL, 817 H

EN

DE

RS

ON

ST

RE

ET

CO

LU

MB

IA, S

OU

TH

CA

RO

LIN

A 2

9208

JO

B N

O.

1200321

LS

W

AH

LM

15 J

AN

UA

RY

2020

PR

OJ. N

O.: H

27-Z

407

50003375-2

PR

OJ.

NO

.: H

27-Z

407 5

0003375-2

SCALE: 1/8" = 1'-0"A1FLOOR PLAN - RENOVATION

SCALE: = 1'-0"

0 8 168

1/8"

NORTHSCALE: 1/8" = 1'-0"A3REFLECTED CEILING PLAN - RENOVATION

NORTH

KEYNOTE LEGEND RENOVATION PLANS

KEY# KEYNOTE DESCRIPTION

1 PROVIDE NEW AUDITORIUM SEATING (282 SEATS) WITH 151 SQ. IN. TABLETARM. BASIS OF DESIGN IS IRWIN SEATING COMPANY OR EQUAL (SEESPECIFICATIONS FOR APPROVED EQUALS). AUDITORIUM SEATING WILL NOTBE POWERED WITH THE EXCEPTION OF THE AISLE LIGHT.

2 NEW PROJECTION SCREEN SHALL BE WALL MOUNTED UNDERNEATHEXISTING SCREEN. POWER NEEDS TO BE DISCONNECTED ANDRECONNECTED (D/R). LOW VOLTAGE SCREEN CONTROL WIRING WILL NEEDTO BE PROVIDED FROM SCREEN INTERFACE TO AV RACK. GC TOCOORDINATE DELIVERY OF OWNER PURCHASED SCREEN. GC TO INSTALLAND CONNECT SCREEN AS REQUIRED. PROVIDE BLOCKING ASRECOMMENDED BY MANUFACTURER.

3 NEW AISLE LIGHTING SHALL BE PROVIDED WITH NEW SEATS, EVERY OTHERROW. COORDINATE POWER LOCATIONS WITH ELECTRICAL DRAWINGS.

4 PROVIDE NEW STAIR NOSINGS ACROSS FULL WIDTH OF RISERS AT MAINAISLES AND STAGE. PROVIDE NEW CARPETING (TYP. THROUGHOUT THEROOM), INCLUDING THE FACES OF RISERS AND STAGE. NEW CARPETINGSHALL BE INSTALLED PRIOR TO NEW SEAT INSTALLATION. PROVIDE NEWWALL BASE IN ITS ENTIRETY (TYP. THROUGHOUT ROOM). SEE FINISHSCHEDULE ON SHEET A-631 FOR STAIR NOSING MATERIAL.

5 PAINT ALL EXISTING WALLS LOCATED IN ROOM 153 OF GAMBRELL HALL.SEE FINISH SCHEDULE ON SHEET A-631.

6 NEW LECTERN PROVIDED AND INSTALLED BY UNIVERSITY OF SOUTHCAROLINA. COORDINATE LOCATION WITH UNIVERSITY OF SOUTHCAROLINA.

7 NEW GRILLE CLOTH FABRIC OVER EXISTING SPEAKER. SEE FINISHSCHEDULE ON SHEET A-631 - ALTERNATE #1.

8 NEW LED DIMMABLE DOWNLIGHTS (TYP.). SEE ELECTRICAL.

9 NEW ACOUSTICAL PANELS ABOVE STAGE. SEE FINISH SCHEDULE ON SHEETA-631.

10 EXISTING CEILING - (FLEXIBLE WOOD COVERING OVER PLASTER ON METALLATH) TYP.

11 EXISTING SUPPLY AIR DIFFUSER (TYP.)

12 EXISTING AREA OF RETURN AIR SLOTS BETWEEN WOODEN STRIPS.

13 REFURBISH EXISTING DOORS - PAINT INTERIOR, THOROUGHLY CLEANEXTERIOR FACE, NEW BLACK KICKPLATE AT EXTERIOR AND NEW CLOSERS.SEE SHEET A-601

14 PROVIDE NEW PANIC DOOR HARDWARE

15 ENCLOSE EXISTING AV CABINET AREA WITH NEW WALL, TYPE F. SEE A-002.

MA

RK

DE

SC

RIP

TIO

ND

AT

E

WhiteL
Stamp
WhiteL
LSW Seal
Page 7: 1 2 3 4 5 GAMBRELL 153 AUDITORIUM UNIVERSITY OF SOUTH …purchasing.sc.edu/solicitations/s_1579299873.pdf · 2020-01-17 · 133 sf 137 sf 137 sf 129 sf 137 sf 353 sf 596 sf 294 sf

NO WORK THIS AREA

MITER WALL BASE, TYP.

EXISTING LIGHTENCLOSURE FORUP & DOWN LIGHTS, TYP.

NEW WALL INFILL SEE, SHEET A-002 FOR PARTITION TYPES &DETAILS

NEW WALL MOUNTEDPROJECTION SCREEN.PROVIDE BLOCKING PER MANUFACTUER RECOMMENDATION.

EXISTING CEILING (FLEXIBLE WOOD COVERING OVER PLASTER ON METAL LATH) TYP.

EXISTING STRUCTURE, TYP.

EXISTING PROJECTION SCREEN ABANDONED INPLACE

*NOTE: SEATING, OMMITED FOR CLARITY

A-301

A1

NEW GRILLE CLOTH FABRIC OVER EXISTING SPEAKERS. SEE FINISH SCHEDULE ON SHEET A-631 - ALTERNATE #1.

PROJECTION

ROOM253

AUDITORIUM

153

(FIE

LD

VE

RIF

Y)

5' -

11"

CLEAN TOP SURFACEOF CURVE - ENTIRE LENGTH

NEW ACOUSTICAL PANEL ATTACHED TO EXISTING WALL. SEE SHEET A-631AND SPECIFICATIONS

EXISTING CEILING (FLEXIBLE WOODCOVERING OVERPLASTER ON METALLATH) TYP.

FIE

LD

VE

RIF

Y

2' -

2"

3'-0" (FIELD VERIFY)

FV

.

4"

FV

.

4"

1'-6" (FIELD VERIFY)

NEW STAIR NOSINGS, SEE SHEET A-631 AND SPECIFICATIONS

NEW CARPET, SEE SHEET A-631 AND SPECIFICATIONS

1 2 3 4 5

A

B

C

D

SHEET OF

SHEET ID

1301 G

erv

ais

Str

eet,

Suite 1

300

Colu

mbia

, S

C 2

9201

Phone (

803)

799-6

502

ww

w.p

ondco.c

om

SIZ

E:

AN

SI D

FIL

E N

AM

E:

SU

BM

ITT

ED

BY

:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

DE

SIG

NE

D B

Y:

ISS

UE

DA

TE

:

SO

LIC

ITA

TIO

N N

O.:

CO

NT

RA

CT

NO

.:

FIL

E N

UM

BE

R:

Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.

STAMP/SEAL

1/1

4/2

020

11:0

8:4

7 P

MC

:\U

se

rs\w

hite

l\D

ocum

en

ts\U

SC

Gam

bre

ll A

ud

itoriu

m_

Arc

h-I

_v1

9_

wh

itel2

6X

5B

.rvt

A-301

CONSTRUCTION DOCUMENTS

SE

CT

ION

/ELE

VA

TIO

N &

DE

TA

ILS

GA

MB

RE

LL 1

53 A

UD

ITO

RIU

MU

NIV

ER

SIT

Y O

F S

OU

TH

CA

RO

LIN

AC

OLU

MB

IA,

SO

UT

H C

AR

OLIN

A

UN

IVE

RS

ITY

OF

SO

UT

H C

AR

OLIN

A

GA

MB

RE

LL H

ALL, 817 H

EN

DE

RS

ON

ST

RE

ET

CO

LU

MB

IA, S

OU

TH

CA

RO

LIN

A 2

9208

JO

B N

O.

1200321

LS

W

AH

LM

15 J

AN

UA

RY

2020

PR

OJ. N

O.: H

27-Z

407

50003375-2

PR

OJ.

NO

.: H

27-Z

407 5

0003375-2

SCALE: 1/4" = 1'-0"A2SECTION/ELEVATION

SCALE: 1/2" = 1'-0"A1CEILING DETAIL

SCALE: 3" = 1'-0"B1STAIR NOSING DETAIL

MA

RK

DE

SC

RIP

TIO

ND

AT

E

whitel
Rectangle
whitel
Stamp
whitel
LSW Seal
Page 8: 1 2 3 4 5 GAMBRELL 153 AUDITORIUM UNIVERSITY OF SOUTH …purchasing.sc.edu/solicitations/s_1579299873.pdf · 2020-01-17 · 133 sf 137 sf 137 sf 129 sf 137 sf 353 sf 596 sf 294 sf

A B

SEE DOOR SCHED. SEE DOOR SCHEDULE

SE

E D

OO

R S

CH

ED

ULE

SE

E D

OO

R S

CH

ED

ULE

GENERAL NOTES:1. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS WITHIN THE SCOPE OF WORK.2. REFER TO SPECIFICATION SECTION 08 71 00 FOR DOOR HARDWARE SETS.

DOOR SCHEDULE

DO

OR

NU

MB

ER

SIN

GLE

(S

) O

R P

AIR

(P

R)

PANEL FRAME

FIR

E R

AT

ING

HA

RD

WA

RE

SE

T

COMMENTS

SIZE

TY

PE

MA

TE

RIA

L

GLA

ZIN

G

TY

PE

FR

AM

E M

AT

ER

IAL

HE

AD

JA

MB

SIL

L

WID

TH

HE

IGH

T

TH

ICK

NE

SS

153 6' - 0" 7' - 0" 1 3/4" B WOOD NA HM EXISTING --- 01

153B 3' - 0" 7' - 0" 1 3/4" A WOOD NA HM --- 02

153D 6' - 0" 7' - 0" 1 3/4" B WOOD NA HM --- 01

S

P

P

PROVIDE NEW BLACK KICK PLATES AND NEW FLOOR CLOSERS.

PROVIDE NEW BLACK KICK PLATES AND NEW FLOOR CLOSERS.

PROVIDE NEW PANIC DOOR HARDWARE.EXISTING

EXISTING

EXISTING EXISTING

EXISTINGEXISTING

EXISTING EXISTING

EXISTING

EXISTING

EXISTING

3. EXISTING DOORS & DOOR FRAMES WITHIN THE SCOPE OF WORK SHALL RECEIVE 2 COATS OF PAINT (TO MATCH WALLS).SEE FINISH SCHEDULE ON SHEET A-631.CARPET IS TO BE CUT AROUND THE FLOOR CLOSERS SO THAT THEY CAN BE ACCESSED AND SERVICED.4.

1 2 3 4 5

A

B

C

D

SHEET OF

SHEET ID

1301 G

erv

ais

Str

eet,

Suite 1

300

Colu

mbia

, S

C 2

9201

Phone (

803)

799-6

502

ww

w.p

ondco.c

om

SIZ

E:

AN

SI D

FIL

E N

AM

E:

SU

BM

ITT

ED

BY

:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

DE

SIG

NE

D B

Y:

ISS

UE

DA

TE

:

SO

LIC

ITA

TIO

N N

O.:

CO

NT

RA

CT

NO

.:

FIL

E N

UM

BE

R:

Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.

STAMP/SEAL

1/1

4/2

020

11:0

8:4

7 P

MC

:\U

se

rs\w

hite

l\D

ocum

en

ts\U

SC

Gam

bre

ll A

ud

itoriu

m_

Arc

h-I

_v1

9_

wh

itel2

6X

5B

.rvt

A-601

CONSTRUCTION DOCUMENTS

DO

OR

SC

HE

DU

LE

& D

ET

AIL

S

GA

MB

RE

LL 1

53 A

UD

ITO

RIU

MU

NIV

ER

SIT

Y O

F S

OU

TH

CA

RO

LIN

AC

OLU

MB

IA,

SO

UT

H C

AR

OLIN

A

UN

IVE

RS

ITY

OF

SO

UT

H C

AR

OLIN

A

GA

MB

RE

LL H

ALL, 817 H

EN

DE

RS

ON

ST

RE

ET

CO

LU

MB

IA, S

OU

TH

CA

RO

LIN

A 2

9208

JO

B N

O.

1200321

LS

W

AH

LM

15 J

AN

UA

RY

2020

PR

OJ. N

O.: H

27-Z

407

50003375-2

PR

OJ.

NO

.: H

27-Z

407 5

0003375-2

SCALE: 3/8" = 1'-0"C2DOOR PANEL TYPES

MA

RK

DE

SC

RIP

TIO

ND

AT

E

whitel
Rectangle
whitel
whitel
LSW Seal
Page 9: 1 2 3 4 5 GAMBRELL 153 AUDITORIUM UNIVERSITY OF SOUTH …purchasing.sc.edu/solicitations/s_1579299873.pdf · 2020-01-17 · 133 sf 137 sf 137 sf 129 sf 137 sf 353 sf 596 sf 294 sf

UP

DN DN

DN

207 SF

MEN244 SF

WOMEN312 SF

1403 SF

99 SF

2431 SF

53 SF

45 SF

77 SF

263 SF

ST05

157

158

159

153

153A

153C

H108

152151

V103

ST05

157

158159153

153A

153C

H108

156

V103

DOOR

TOLOWER

LEVELCORRIDOR

H012

UP

DN DN

DN

207 SF

MEN244 SF

WOMEN312 SF

1403 SF

99 SF

2431 SF

53 SF

45 SF

77 SF

263 SF

ST05

157

158

159

153

153A

153C

H108

152151

V103

ST05

157

158159153

153A

153C

H108

156

V103

AUDITORIUM153

STOR.153A STOR.

153C

LEGEND

CPT-1

NIC

STAIR NOSING

DOOR TO LOWER LEVEL CORRIDOR H012

N.I.C.DL-1 DL-1

CPT CARPETP PAINTTP TRIM PAINTRB RUBBER BASE

MATERIALS & FINISHES ABBREVIATIONS LIST

R1.

REMARKS

EXISTING PAINTED WOOD DOORS AND HMF TO BE PAINTED TP-1

(BASIS OF DESIGN) SEE SPECIFICATIONS FOR APPROVED , EQUALS AND SUBSTITUTION REQUESTS

WALLS

P-1 PAINT: SHERWIN WILLIAMS, CREAMY SW7012, SEMIGLOSSTP-1 TRIM PAINT: SHERWIN WILLIAMS, CREAMY SW7012, SEMIGLOSS

WALL BASE

RB-1 RUBBER WALL BASE: JOHNSONITE, 4" COVE BASE, 40 BLACK B

FLOOR

CPT-1 CARPET: BENTLEY MILLS, MISFIT #8FW24-801787, COLOR: BENEVOLENT, BROADLOOM INSTALLATION

MISC.

STAIR NOSING, TREDSAFE #AA346 ALUMINUM SAFETY TREAD W/ GLOW STRIPE, COLOR: CHARCOAL GREY 107

DL-1 REPLACE DAMAGED BLACK LAMINATE ON DOORS.

NOTE: CARPET IS TO BE CUT AROUND THE NEW FLOOR CLOSERS SO THAT THEY CAN BE ACCESSED AND SERVICED.

FINISH LEGEND

AUDITORIUM153

STOR.153A STOR.

153C

N.I.C. (TYP)

1 2 3 4 5

A

B

C

D

SHEET OF

SHEET ID

1301 G

erv

ais

Str

eet,

Suite 1

300

Colu

mbia

, S

C 2

9201

Phone (

803)

799-6

502

ww

w.p

ondco.c

om

SIZ

E:

AN

SI D

FIL

E N

AM

E:

SU

BM

ITT

ED

BY

:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

DE

SIG

NE

D B

Y:

ISS

UE

DA

TE

:

SO

LIC

ITA

TIO

N N

O.:

CO

NT

RA

CT

NO

.:

FIL

E N

UM

BE

R:

Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.

STAMP/SEAL

1/1

4/2

020

11:0

8:4

8 P

MC

:\U

se

rs\w

hite

l\D

ocum

en

ts\U

SC

Gam

bre

ll A

ud

itoriu

m_

Arc

h-I

_v1

9_

wh

itel2

6X

5B

.rvt

A-631

CONSTRUCTION DOCUMENTS

FIN

ISH

SC

HE

DU

LE

& F

UR

NIT

UR

E P

LA

N

GA

MB

RE

LL 1

53 A

UD

ITO

RIU

MU

NIV

ER

SIT

Y O

F S

OU

TH

CA

RO

LIN

AC

OLU

MB

IA,

SO

UT

H C

AR

OLIN

A

UN

IVE

RS

ITY

OF

SO

UT

H C

AR

OLIN

A

GA

MB

RE

LL H

ALL, 817 H

EN

DE

RS

ON

ST

RE

ET

CO

LU

MB

IA, S

OU

TH

CA

RO

LIN

A 2

9208

JO

B N

O.

1200321

ED

M

ED

M

LM

15 J

AN

UA

RY

2020

PR

OJ. N

O.: H

27-Z

407

50003375-2

PR

OJ.

NO

.: H

27-Z

407 5

0003375-2

SCALE: 1/8" = 1'-0"A2FINISH PLAN

FINISH SCHEDULESPACE FLOOR WALLS CEILING

REMARKSROOM NO. ROOM NAME MAT. BASE NORTH EAST SOUTH WEST FIN.

153 AUDITORIUM CPT-1 RB-1 P-1 P-1 P-1 P-1 EXT R1

153A STOR. CPT-1 RB-1 P-1 P-1 P-1 P-1 EXT R1

153C STOR. CPT-1 RB-1 P-1 P-1 P-1 P-1 EXT R1

NORTH

SCALE: = 1'-0"

0 8 168

1/8"SCALE: 1/8" = 1'-0"A1FURNITURE PLAN

MA

RK

DE

SC

RIP

TIO

ND

AT

E

whitel
Rectangle
whitel
Stamp
whitel
LSW Seal
Page 10: 1 2 3 4 5 GAMBRELL 153 AUDITORIUM UNIVERSITY OF SOUTH …purchasing.sc.edu/solicitations/s_1579299873.pdf · 2020-01-17 · 133 sf 137 sf 137 sf 129 sf 137 sf 353 sf 596 sf 294 sf
whitel
Snapshot
Page 11: 1 2 3 4 5 GAMBRELL 153 AUDITORIUM UNIVERSITY OF SOUTH …purchasing.sc.edu/solicitations/s_1579299873.pdf · 2020-01-17 · 133 sf 137 sf 137 sf 129 sf 137 sf 353 sf 596 sf 294 sf
whitel
Snapshot