- Condensate pump and feed pump trip!- Turbine trips!
2
![Page 3: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/3.jpg)
- Condensate pump and feed pump trip!- Turbine trips!- Temperature and pressure in the primary loop is increasing!
3
![Page 4: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/4.jpg)
- Relief valves opens in the pressurizer !
OPEN
4
![Page 5: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/5.jpg)
- Control rods are inserted !
OPENINSERTED
5
![Page 6: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/6.jpg)
- Pressure in the primary loop is decreasing !
INSERTED
6OPEN
![Page 7: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/7.jpg)
- Emergency feed pump is now in operation !
INSERTED
OPERATION
7OPEN
![Page 8: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/8.jpg)
- Relief valve is closed !
INSERTED
OPERATION
8
![Page 9: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/9.jpg)
- Pressure in the primary loop is decreasing !
INSERTED
OPERATION
9
![Page 10: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/10.jpg)
- Water level in the stream generator is decreasing !
INSERTED
OPERATION
10
![Page 11: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/11.jpg)
- Pressure in the primary loop is decreasing !
INSERTED
OPERATION
11
![Page 12: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/12.jpg)
INSERTED
OPERATION
12
- Water level in the pressurizer is gradually increasing !- Pressure in the primary loop is decreasing !
![Page 13: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/13.jpg)
INSERTED
OPERATION
13NO WATER
- There is no water in the steam generator !
![Page 14: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/14.jpg)
INSERTED
OPERATION
14NO WATER
- Water level in the pressurizer is gradually increasing !- Pressure in the primary loop is decreasing !
![Page 15: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/15.jpg)
INSERTED
OPERATION
15NO WATER
- Why is pressure in the primary loop decreasing even though water level is increasing?
![Page 16: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/16.jpg)
INSERTED
OPERATION
16NO WATER
- Water level in the pressurizer is gradually increasing !- Pressure in the primary loop is decreasing !
![Page 17: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/17.jpg)
- Emergency core cooling system is now in operation !
INSERTED
OPERATION
WATER IS INJECTED
17NO WATER
![Page 18: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/18.jpg)
- Water level in the pressurizer is increasing !- Pressure in the primary loop is decreasing !
INSERTED
OPERATION
WATER IS INJECTED
18NO WATER
![Page 19: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/19.jpg)
- It might be dangerous if the amount of water is too much in the primary loop…
INSERTED
OPERATION
WATER IS INJECTED
19NO WATER
![Page 20: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/20.jpg)
- Water level in the pressurizer is increasing !- Pressure in the primary loop is decreasing !
INSERTED
OPERATION
WATER IS INJECTED
20NO WATER
![Page 21: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/21.jpg)
- Emergency core cooling system is operated by the manual mode from now !
INSERTED
OPERATION
WATER IS INJECTED
21NO WATER
![Page 22: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/22.jpg)
- Water level in the pressurizer is increasing !- Pressure in the primary loop is decreasing !
INSERTED
OPERATION
WATER IS INJECTED
22NO WATER
![Page 23: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/23.jpg)
- One of two emergency core cooling systems is manually stopped and the injection water from the other one is reduced.
INSERTED
OPERATION
WATER IS INJECTED
23NO WATER
![Page 24: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/24.jpg)
- Water level in the pressurizer is increasing !- Pressure in the primary loop is decreasing !
INSERTED
OPERATION
WATER IS INJECTED
24NO WATER
![Page 25: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/25.jpg)
- Water level is reaching the top of the pressurizer !
INSERTED
OPERATION
WATER IS INJECTED
25NO WATER
FULL WATER
![Page 26: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/26.jpg)
- Water in the pressurizer is full, but measurement data at other positions in the primary loop do NOT show consistent results…
INSERTED
OPERATION
WATER IS INJECTED
26NO WATER
FULL WATER
![Page 27: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/27.jpg)
INSERTED
OPERATION
WATER IS INJECTED
27NO WATER
FULL WATER
- Water level is at the top of the pressurizer !- Pressure of the primary loop is decreasing !
![Page 28: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/28.jpg)
- Water level is at the top of the pressurizer !- Pressure of the primary loop is decreasing !- Water in the containment sump is moved to the auxiliary building.
INSERTED
OPERATION
WATER IS INJECTED
28NO WATER
FULL WATER
![Page 29: 1. - Condensate pump and feed pump trip! -Turbine trips! 2](https://reader033.vdocuments.net/reader033/viewer/2022061616/56649edc5503460f94bec0bb/html5/thumbnails/29.jpg)
- The block values on the emergency feed water line pump have been CLOSE ! Why !
- Now it is OPEN !
INSERTED
OPERATION
WATER IS INJECTED
29FULL WATER