1 eigenmannia: glass knife fish a weakly electric fish electrical organ discharges (eods) –...

35
1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) Individually fixed between 250 and 600 Hz Method of electrolocation and communication Electroreceptors: Respond to phase (T-type) Respond to amplitude (P-type)

Upload: rosalyn-lyons

Post on 18-Dec-2015

216 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

1

Eigenmannia: Glass Knife FishA Weakly Electric Fish

• Electrical organ discharges (EODs)– Individually fixed between 250 and 600 Hz

– Method of electrolocation and communication

• Electroreceptors:– Respond to phase (T-type)

– Respond to amplitude (P-type)

Page 2: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

2

Jamming Avoidance Response• Two fish will adjust EOD if frequencies

are similar enough.

• Before: Fish A: 304 Hz, Fish B 300 Hz.

• After: Fish A: 312 Hz, Fish B 292 Hz.

• Uses T-type and P-type receptors to compute whether EODs should be raised or lowered.

• Role of T-type well understood. This paper examines the role of P-type.

Electrical Field

Page 3: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

3

The P-type Receptor Cells• Single afferent projections to Electrosensory

Lateral Line (ELL) lobe of the medulla• Tuned to the EOD frequency of the individual• Loosely phase locked• Fire < 1 per electric cycle, though as amplitude

increase firings/per cycle goes to one

Page 4: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

4

Stimulus and Electrophysiology

• T = Blank Tape Produces White Noise (the stimulus)– Can vary the Standard

Deviation• BF = Output passed through

low-pass filter with variable cut-food frequency– Can Vary the Cut-Off

Frequency (fc)• FG = function generator (next

slide)• Electrodes in Mouth and Near

tail produce electric field, to which receptors respond

Insert 1A here

Page 5: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

5

The Function Generator

• A0 is the Mean Amplitude

• s(t) is the white noise after it has passed through a filter

• fcarrier is equal to the EOD

Page 6: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

6

Recordings• Recordings of P-type receptors at the animals

trunk• Identified P-type receptors by 3 criteria:

– Probability of firing per cycle < 1 – Spontaneous activity was irregular– Units phase locked with large jitter

• 26 units selected• Recordings of 135 seconds for 3 Protocols

– Spontaneous activity– Response to wide-band white noise (fc= 740 Hz)– Varying fc, Ao, and standard deviation of s(t) in a

pseudo random manner

Page 7: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

7

Theory

• A linear estimate of the stimulus given the spike train obtained by convolving the spike train with the filter

• We represent the spike train, resulting from the stimulus, to be

ti – spike occurrence time

X0 – mean firing rate.

Page 8: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

8

• h(t) was chosen to minimize the square error between

the stimulus and the stimulus estimate

• The integration is over the duration of the experiment (T=135sec)• fc is cut-off frequency• Ssx is Fourier transform of the cross correlation function of the stimulus and the spike train.• Sxx is the Fourier transform of the auto correlation function stimulus and the spike train.

Page 9: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

9

Now we can determine:

• We determine “noise”, as the distance between the original stimulus and the estimated stimulus:

• Signal To Noise Ratio, SNR(f), as the power spectrum of the of the stimulus divided by the power spectrum of the noise

Measure the amount of signal power present at a given frequency relative to the noise. SNR = 1 means that it is impossible to differ the signal from the noise.

Page 10: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

10

• Measure of rate of mutual information that is transmitted by the reconstructions about the stimulus.

• Dividing by the firing rate λ , yields the mutual information transmitted per spike Is=Ie/ λ

• Coding Fraction, a normalized measure of the quality of reconstruction

( 0 < γ < 1 ), and for max error γ is 0

(Mean square error in the reconstruction)

Page 11: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

11

Data AnalysisHow we obtained the data for the above equations:

• Spike Sample: The spike peak occurrences times were selected and resample at 2KHz together with the stimulus.(2KHz because we saw that we are interested in frequencies bellow 740, say 1000 and then nyquist…)

• Filter:- Estimate of the cross correlation between spike trains and stimulus was obtained by Fast Fourier transform. (Ssx,Sxx)

• SNR:- Estimate of the stimulus and spikes power spectra were obtained using Fast Fourier transform and averaging 130 samples of data, each 1024msec long.

Page 12: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

12

• The stimulus estimation were obtained by convolving the filter and the spike train in the frequency domain using Fast Fourier Transform. Here to avoid contamination by the carrier frequency of the spike train, they set the filter to zero for frequencies greater than fcarrier – 30Hz.

• Experimental errors were either obtained directly by repeated measurements or by error propagation

Page 13: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

13

ResultsResponse to sinusoidal stochastic amplitude modulations –

spontaneous activity

• P-type receptor afferent units fire with increased probability when the amplitude of the external electric field is raised.

10Hz sinusoidal amplitude modulation and the corresponding poststimulus histogram.

Page 14: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

14

• The spontaneous activity of P units appears consistent with the assumptions of stationary probability density for the spike distribution.

Page 15: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

15

• Increasing mean stimulus amplitude, increase the probability of firing.

A=0.1, λ= 24

A=0.2, λ= 55

A=0.3, λ= 98

A=0.4, λ=112

A=0.5, λ=152

A=0.6, λ=174

A=0.8, λ=208

A=1.0, λ=233

Page 16: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

16

Temporal Bandwidth

For wide band white noise stimulus 740Hz, checking over13 units:• SNR always equal to 1 for frequencies > 200Hz.

and reconstruction is poor γ = 0.0024 (<2.5%)For white noise stimulus 175Hz, while keeping power spectrum constant.• SNR improved and more faithful reconstruction γ =

0.222.

Page 17: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

17

Cutoff Frequency

• The coding fraction γ decreased with increasing fc.

• Decreasing the fc of the stimulus, increase the SNR at lower frequencies.

Page 18: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

18

Why?1. The power spectra density was increased in the range of

frequencies encoded by the units.2. The power spectra density of the signal was reduced at

high frequencies.Two experiments were made to check these assumption.- fc of the stimulus was kept fixed, and the power

density was increased.- fc of the stimulus was increased, and the power

density was kept constant.

Page 19: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

19

Effect of Mean Firing Rate

• Dynamic Range of mean firing rate from spontaneous firing rate to fcarrier (limit once/cycle)

• Signal-to-Noise Ratio increases as firing rate increases, but saturates at ½ fcarrier

Page 20: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

20

Coding Fraction, Information Rate, Information Per Spike

• Coding Fraction, Information Rate also increases and saturates at the same points (Figure a and b), while Information per Spike decreases upon saturation (c)

• Lower Cut-Off Frequency Steeper slope in Coding Fraction

– fc =175 vs. fc =88 Hz

• No significant influence of the spontaneous firing rate on the slope of the coding fraction. (Fig. A and B)

• Significant coding occurred 20-40 Hz above spontaneous discharge

Page 21: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

21

Page 22: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

22

Standard Deviation and Signal-to-noise Ratio

• Varying the Standard Deviation is the same as increasing the amplitude

• Max. standard deviation set at .25 to avoid phase changes

• Signal-to-Noise Ratio increases with standard deviation

Page 23: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

23

Coding Fraction, Information Rate, Information

Per Spike

• All three of these increase with Standard Deviation

• Dotted lines are one unit at three mean firing rates (bottom 70, middle 110, and top 170)

• Larger mean firing rates:

– Initial slope larger

– Saturation reached at lower standard deviation

Page 24: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

24

Page 25: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

25

Discussion

• Studied Encoding Information– Signal-to-Noise– Mutual Information Rate– Coding Fraction

• Despite the Noise, single afferents encode much of the stimulus

Page 26: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

26

Technical Considerations

• The head and tail electric field geometry most effective in jamming avoidance response

• They may have chosen T-Type cells, however their data suggest otherwise (P-Type).

Page 27: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

27

Reverse Correlation and Linear Reconstruction Filter

• Spiked were typically triggered by large positive slope in the stimulus.

• Neither the Biophysical interpretation nor the computational properties that could be read from the filter are obvious.

• The filter h(t) changes when the statistics of the stimulus or the mean firing rate of the units changes.

Page 28: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

28

• Their observation of the filter argue against the notion that there is a single cell that explicitly reconstruct the stimulus.

• The results are true for the assumption that the white noise stimuli is coded with stationary statistics and that the spike train is stationary in response to the stimulus.

Page 29: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

29

Existence of nonlinearities

• The experiment show that adding high frequencies to the stimulus reduce the signal to noise ratio at low frequencies. This indicates that the receptors’ response to electric field amplitude modulation is nonlinear.

Page 30: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

30

Natural stimuli

1. A typical power spectrum of natural amplitude modulations around the fish in its natural behavior

has not been measured.

2. Amplitude modulations caused by small moving objects have been estimated to be between 2 –

80Hz.They showed that SNR and fraction of signal encoded in single spike trains increase as the cutoff frequency of the stimulus decrease between 740-88Hz. (slide18)

More experiments were done, decreasing fc to 2, 20, 50 that verified these results.

Page 31: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

31

mean firing rate, dynamic range spontaneous activity

• The mean firing rate λ, increase with the mean amplitude A0.

This enable them to study the coding performances as function of λ by changing A of the stimulus.

• The SNR, mutual information rate and coding fraction increased with increasing mean firing rate, for firing rates between the spontaneous activity and half of fcarrier.

• Coding started for mean firing rates 20-40Htz above the spontaneous discharge.

Page 32: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

32

• Coding fraction and mutual information both reached maximum at about half of fcarrier.

• There is a differential sensitivity of the coding fraction and the mutual information transmission as fc of the stimulus was changed.

• Anesthetized fish have lower spontaneous activity and EOD frequency, thus reduced firing rate than untreated fish, therefore the measured firing rate may not be the optimal one.

Page 33: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

33

Standard Deviation and Contrast

• Coding Fraction, etc. increased with an increase in Standard Deviation

• Because Mean Firing Rate was constant and only Standard Deviation changed, better performance was not due to more firing

Page 34: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

34

Upper Bound on Performance

• Upper Bound = fcarrier because max of one spike per electric cycle

• Coding fraction at upper bound given by equation below.

• For these experiments fcarrier = 400 Hz and fc = 100 Hz, so coding fraction is 0.75

• P receptors can code >1/2 the information that can be encoded about a stimulus

Page 35: 1 Eigenmannia: Glass Knife Fish A Weakly Electric Fish Electrical organ discharges (EODs) – Individually fixed between 250 and 600 Hz –Method of electrolocation

35

Behavioral Relevance

• Information from the P receptors to the CNS depends on: – Mean firing rate– fc of the stimulus, as will as its contrast– Similar results in mammalian visual system?

• Individual P receptors covey accurate and efficient representation– Convergence makes more accurate and more

efficient?