• Indoor Units • R410A • FDXS-CVMB
11
• Split Sky Air • Indoor Units1
1 Features
Indoor Unit Split Sky A FDXS-CVMB R410A • Extremely quiet in operation
• You have the choice out of 5 fan speeds to select
• Daikin’s special dry programme reduces humidity in the room without variation in room temperature
• Powerful mode can be selected for rapid cooling or heating
• Night set mode saves energy by preventing overcooling or overheating during night time
• Standard suction filter: removes airborne dust particles to ensure a steady supply of clean air
• Compact dimensions, can easily be mounted in a ceiling void of only 240mm
• Daikin remote controls give you easy control at your f ingert ips.
optional 5 steps standard
![Page 2: 1 Features - ΚΛΙΜΑΜΗΧΑΝΙΚΗ · 1 Features A t i y nk UBS M V r tC o-A oi S0 dlX1 npD4 SRIF• Extremely quiet in operation • You have the choice out of 5 fan speeds](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78dbaf236e4a6c18222e8d/html5/thumbnails/2.jpg)
3
12
• Split Sky Air • Indoor Units 2
• Indoor Units • R410A • FDXS-CVMB
2 Specifications
2-1 FOR INDOOR UNITS ONLY FDXS5 0CVMB FDXS60C VMB
Nominal Input Cooling kW 0.140 0.160Heating kW 0.140 0.160
2-2 TECHNICAL SPECIFICATIONS FDXS5 0CVMB FDXS60C VMB
Dimensions Packing Height mm 266 266Width mm 1106 1306Depth mm 751 751
Unit Height mm 200 200Width mm 900 1100Depth mm 620 620
Weight Unit kg 27.0 30.0Packed Unit kg 34.0 37.0
Heat Exchanger
Dimensions Length mm 700 900Nr of Rows 3 2Fin Pitch mm 1.50 1.50Nr of Stages 12 12
Tube type Hi-XSS (7)Fin Type ML fin (Multi louver)
Fan Type Sirocco fanAir Flow Rate Cooling High m³/min 12.0 16.0
Medium m³/min 11.0 14.8Low m³/min 10.0 13.5Silent Operation
m³/min 8.4 11.2
Heating High m³/min 12.0 16.0Medium m³/min 11.0 14.8Low m³/min 10.0 13.5Silent Operation
m³/min 8.4 11.2
Fan Max Standard Pa 40 40Motor Quantity 1 1
Model 130J-23Number of steps 5 s teps, si lent and auto
Motor Speed (cooling)
High rpm 1270 1280Medium rpm 1180 1160Low rpm 1080 1040Silent Operation
rpm 930 890
Speed (heating)
High rpm 1270 1280Medium rpm 1180 1160Low rpm 1080 1040Silent Operation
rpm 930 890
Fan Motor Output (high)
W 130 130
Cooling Sound Power High dBA 55.0 56.0Sound Pressure
High dBA 37.0 38.0Medium dBA 35.0 36.0Low dBA 33.0 34.0Silent Operation
dBA 31.0 32.0
Heating Sound Power High dBA 55.0 56.0Sound Pressure
High dBA 37.0 38.0Medium dBA 35.0 36.0Low dBA 33.0 34.0Silent Operation
dBA 31.0 32.0
Refrigerant Type R-410A
![Page 3: 1 Features - ΚΛΙΜΑΜΗΧΑΝΙΚΗ · 1 Features A t i y nk UBS M V r tC o-A oi S0 dlX1 npD4 SRIF• Extremely quiet in operation • You have the choice out of 5 fan speeds](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78dbaf236e4a6c18222e8d/html5/thumbnails/3.jpg)
• Indoor Units • R410A • FDXS-CVMB
12
• Split Sky Air • Indoor Units3
2 Specifications
Piping connections
Liquid (OD) Diameter (OD)
mm 6.4 6.4
Gas Diameter (OD)
mm 12.7 12.7
Drain Diameter (OD)
mm I.D. 20/O.D. 26
Heat Insulation Both liquid and gas pipesAir Filter Removable/washable/Mildew proofAir direction control Left, r ight, up and downwardsTemperature control Microcomputer controlStandard Accessories
Item Installation manualQuantity 1 pcItem Operation manualQuantity 1 pcItem Infrared remote controlQuantity 1 pcItem BatteriesQuantity 2 pcsItem Remote control holderQuantity 1 pcItem Fixing screw for remote controlQuantity 2 pcsItem Signal receiver cover kitQuantity 1 setItem Insulation for fittingQuantity 1 setItem Sealing padQuantity 1 setItem Clamp metalQuantity 1 pcItem Drain hoseQuantity 1 pcItem Washer for hanger bracketQuantity 8 pcsItem Sealing materialQuantity 2 pcsItem ClampsQuantity 6 pcsItem Washer fixing plateQuantity 4 pcsItem Screws for duct flangesQuantity 1 setItem Air fi lterQuantity 1 pc
Notes Sound values are measured in an anechoic room.Sound pressure level is a relative value, depending on the distance and acoustic env ironment. For more details,
please refer to sound level drawings of this chapter.The sound power level is an absolute value indicating the power which a sound source generates.
2-3 ELECTRICAL SPECIFICATIONS FDXS50CVMB FDXS60 CVMB
Power Supply Name VMPhase 1 1Frequency Hz 50/60Voltage V 220-240/220-230
Current Nominal running cur rent (RLA)
Cooling A 0.64 0.74Heating A 0.64 0.74
Wiring connections
For Power Supply
Quantity 3 3Remark 4 for interunit wir ing (inc luded earth wiring)
2-2 TECHNICAL SPECIFICATIONS FDXS50CVMB FDXS60 CVMB
![Page 4: 1 Features - ΚΛΙΜΑΜΗΧΑΝΙΚΗ · 1 Features A t i y nk UBS M V r tC o-A oi S0 dlX1 npD4 SRIF• Extremely quiet in operation • You have the choice out of 5 fan speeds](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78dbaf236e4a6c18222e8d/html5/thumbnails/4.jpg)
3
12
• Split Sky Air • Indoor Units 4
• Indoor Units • R410A • FDXS-CVMB
2 Specifications
Voltage range Minimum -10%Maximum +10%
Power Supply Intake Outdoor unit only
2-3 ELECTRICAL SPECIFICATIONS FDXS5 0CVMB FDXS60C VMB
![Page 5: 1 Features - ΚΛΙΜΑΜΗΧΑΝΙΚΗ · 1 Features A t i y nk UBS M V r tC o-A oi S0 dlX1 npD4 SRIF• Extremely quiet in operation • You have the choice out of 5 fan speeds](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78dbaf236e4a6c18222e8d/html5/thumbnails/5.jpg)
• Indoor Units • R410A • FDXS-CVMB
13
• Split Sky Air • Indoor Units5
3 Dimensional drawing & centre of gravity3 - 1 Dimensional drawing
3D045486D
FDK/XS50C unit (mm)
300 or more
(Service space)
Infrared receiver unit
Signal receiver
(all around)
18-M4 Holes
(all around)
In case bottom-suction
Signal transmitter
Infrared remote controlFDXS - - C(A)VMB: (ARC433A7)FDKS - - C(A)VMB: (ARC433A8)(S
uspe
nsio
nbo
ltpi
tch)
(Suspension bolt pitch)
Home leavelamp
(Service space)
400 or more(In case
bottom-suction)
Ceiling
Room temp. sensorOperation lamp
Timer lamp
16-M5 holes
Cord (length: 1900mm)
20-M5 Holes(all around)
(all around)22-J4.7 Hole
20or
mor
e 20or
mor
e
240
orm
ore
Notes:1. In case of back-suction, mount chamber cover to bottom
side of the unit.In case of bottom-suction, mount chamber cover to backside of the unit.
2. Location of unit’s name plate: control box cover. (unit: mm).3. Mount the air filter at the suction side. (select its
colorimethod (gravity method) 50% or more).It can not be equipped with air filter (accessory) whenconnecting duct to suction side.
4. Pipe specification
1 Liquid pipe connection J6.4 (Flare connection)2 Gas pipe connection NOTE) 4.3 Socket for drain VP20 (O.D. J26 / I.D. J20)4 Drain hose (accessory) I.D. J 25 (Outlet)5 Control box6 Infrared receiver unit connection7 Power supply connection8 Suspension bracket9 Air filter (accessory)
Allow view AInspection door (ceiling
opening)
In case of back suction
Indoor unit ON/OFFswitch
FDX(K)S50 J 12.7 (Flare connection)
3D045487C
FDK/XS60C unit (mm)
300 or more
(Service space)
Infrared receiver unit
Signal receiver
(all around)
18-M4 Holes(all around)
In case bottom-suction
Signal transmitter
Infrared remote controlFDXS60CVMB: (ARC433A7)FDKS60CVMB: (ARC433A8)(S
uspe
nsio
nbo
ltpi
tch)
(Suspension bolt pitch)
Home leavelamp
(Service space)400 or more
(In casebottom-suction)
Ceiling
Room temp. sensorOperation lamp
Timer lamp
24-M5 holesCord (length: 1900mm)
24-M5 holes(all around)
(all around)26-J4.7 Hole
20or
mor
e
20or
mor
e
240
orm
ore
Notes:1. In case of back-suction, mount chamber cover to bottom
side of the unit.In case of bottom-suction, mount chamber cover to backside of the unit.
2. Location of unit’s name plate: control box cover. (unit: mm).3. Mount the air filter at the suction side. (select its
colorimethod (gravity method) 50% or more).It can not be equipped with air filter (accessory) whenconnecting duct to suction side.
1 Liquid pipe connection J6.4 (Flare connection)2 Gas pipe connection J12.7 (Flare connection)3 Socket for drain VP20 (O.D. J26 / I.D. J20)4 Drain hose (accessory) I.D. J 25 (Outlet)5 Control box6 Infrared receiver unit connection7 Power supply connection8 Suspension bracket9 Air filter (accessory)
Allow view AInspection door (ceiling
opening)
In case of back suction
Indoor unit ON/OFFswitch
![Page 6: 1 Features - ΚΛΙΜΑΜΗΧΑΝΙΚΗ · 1 Features A t i y nk UBS M V r tC o-A oi S0 dlX1 npD4 SRIF• Extremely quiet in operation • You have the choice out of 5 fan speeds](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78dbaf236e4a6c18222e8d/html5/thumbnails/6.jpg)
3
13
• Split Sky Air • Indoor Units 6
• Indoor Units • R410A • FDXS-CVMB
3 Dimensional drawing & centre of gravity3 - 2 Centre of gravityFDK/XS50C
4D046081D
![Page 7: 1 Features - ΚΛΙΜΑΜΗΧΑΝΙΚΗ · 1 Features A t i y nk UBS M V r tC o-A oi S0 dlX1 npD4 SRIF• Extremely quiet in operation • You have the choice out of 5 fan speeds](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78dbaf236e4a6c18222e8d/html5/thumbnails/7.jpg)
• Indoor Units • R410A • FDXS-CVMB
13
• Split Sky Air • Indoor Units7
3 Dimensional drawing & centre of gravity3 - 2 Centre of gravityFDK/XS60C
4D046082C
![Page 8: 1 Features - ΚΛΙΜΑΜΗΧΑΝΙΚΗ · 1 Features A t i y nk UBS M V r tC o-A oi S0 dlX1 npD4 SRIF• Extremely quiet in operation • You have the choice out of 5 fan speeds](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78dbaf236e4a6c18222e8d/html5/thumbnails/8.jpg)
3
14
• Split Sky Air • Indoor Units 8
• Indoor Units • R410A • FDXS-CVMB
4 Piping diagram
4D045449F
FDK/XS50-60C
Model AFDXS50CVMBFDKS50CVMBFDXS60CVMBFDKS60CVMB
J 12.7
Field piping
Field piping
Heat exchanger
Fan motor
Sirocco fan
Refrigerant flowCooling
Heating
Indoor unit
Thermistor onheat exchanger
![Page 9: 1 Features - ΚΛΙΜΑΜΗΧΑΝΙΚΗ · 1 Features A t i y nk UBS M V r tC o-A oi S0 dlX1 npD4 SRIF• Extremely quiet in operation • You have the choice out of 5 fan speeds](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78dbaf236e4a6c18222e8d/html5/thumbnails/9.jpg)
• Indoor Units • R410A • FDXS-CVMB
15
• Split Sky Air • Indoor Units9
5 Wiring diagram5 - 1 Wiring diagram
3D045012G
FDK/XS50-60C
gField wiring
Outdoor
Indoor
Infrared remotecontrol
C1 : Capacitor (M1F)F1U : FuseH1P∼H3P : Pilot lampM1F : Fan motorPCB1∼PCB2 : Printed circuit boardQ1M : Thermal protector (M1F embedded)R1T∼R2T : ThermistorS1∼S32,RTH1 : ConnectorS1W : Operation switchV1TR : Phase control circuitX1M : Terminal blockZ1C : Noise filter (ferrite core)R : Protective earth
CAUTIONNotice that operation will restart
automatically when the main powersupply is turned off and then turned
on again.
Signalreceiver
(Terminal for centralisedcontrol)
Transmission circuit
NOTES1 Size: length 60 x width 125.2 Nameplate material: wood free tack paper3 Coat the reverse side with pressure sensitive adhesive4 Refer to purchasing specification AS303002, unless otherwise specified.5 This drawing was drawn on CAD system.6 Make a slit on separate liner in vertical direction
![Page 10: 1 Features - ΚΛΙΜΑΜΗΧΑΝΙΚΗ · 1 Features A t i y nk UBS M V r tC o-A oi S0 dlX1 npD4 SRIF• Extremely quiet in operation • You have the choice out of 5 fan speeds](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78dbaf236e4a6c18222e8d/html5/thumbnails/10.jpg)
3
16
• Split Sky Air • Indoor Units 10
• Indoor Units • R410A • FDXS-CVMB
6 Sound data6 - 1 Sound pressure spectrum
3D046245C
Oct
ave
band
soun
dpr
essu
rele
vel
dB:(0
dB=
0.00
02µ
bar)
Octave band center frequency (Hz)
FDXS50C (Cooling)
approximate thresholdhearing for continuous
noise
NOTES1 Operation noise differs with operation and ambient conditions.2 The operating sound is based on the rear side suction inlet, and the external
static pressure 40Pa.
Legend
(H) 230V/50Hz, 220V/60Hz
(L) 230V/50Hz, 220V/60Hz
DuctDuct SuctionDischarge
Microphone
Location of microphone
3D046245C
Oct
ave
band
soun
dpr
essu
rele
vel
dB:(0
dB=
0.00
02µ
bar)
Octave band center frequency (Hz)
FDXS50C (Heating)
approximate thresholdhearing for continuous
noise
NOTES1 Operation noise differs with operation and ambient conditions.2 The operating sound is based on the rear side suction inlet, and the external
static pressure 40Pa.
Legend
(H) 230V/50Hz, 220V/60Hz
(L) 230V/50Hz, 220V/60Hz
DuctDuct SuctionDischarge
Microphone
Location of microphone
3D046246C
Oct
ave
band
soun
dpr
essu
rele
vel
dB:(0
dB=
0.00
02µ
bar)
Octave band center frequency (Hz)
FDXS60C (Cooling)
approximate thresholdhearing for continuous
noise
NOTES1 Operation noise differs with operation and ambient conditions.2 The operating sound is based on the rear side suction inlet, and the external
static pressure 40Pa.
Legend
(H) 230V/50Hz, 220V/60Hz
(L) 230V/50Hz, 220V/60Hz
DuctDuct SuctionDischarge
Microphone
Location of microphone
3D046246C
Oct
ave
band
soun
dpr
essu
rele
vel
dB:(0
dB=
0.00
02µ
bar)
Octave band center frequency (Hz)
FDXS60C (Heating)
approximate thresholdhearing for continuous
noise
NOTES1 Operation noise differs with operation and ambient conditions.2 The operating sound is based on the rear side suction inlet, and the external
static pressure 40Pa.
Legend
(H) 230V/50Hz, 220V/60Hz
(L) 230V/50Hz, 220V/60Hz
DuctDuct SuctionDischarge
Microphone
Location of microphone
![Page 11: 1 Features - ΚΛΙΜΑΜΗΧΑΝΙΚΗ · 1 Features A t i y nk UBS M V r tC o-A oi S0 dlX1 npD4 SRIF• Extremely quiet in operation • You have the choice out of 5 fan speeds](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78dbaf236e4a6c18222e8d/html5/thumbnails/11.jpg)
• Indoor Units • R410A • FDXS-CVMB
17
• Split Sky Air • Indoor Units11
7 Fan characteristics
3D045762C
FDK/XS50C
Exte
rnal
stat
icpr
essu
re
Air flow (m3/min)
H
L
Upper limit of externalstatic pressure
SL
Lower limit of external staticpressure
3D045763C
FDK/XS60C
Exte
rnal
stat
icpr
essu
re
Air flow (m3/min)
H
L
Upper limit of externalstatic pressure
SL
Lower limit of external staticpressure