Page 1: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

1

HFC11.0Fundamentals of HFC

Page 2: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

2

Agenda

• Basics – AC, DC, Ohm’s law, Units and measurements.• Log, Antilog, why use them loss, gain, power level units?• dB, dBμV, dBmV, dBm and their conversions.• Passives, types of passives, functions of different passives.• What is network? Different network architectures.• Homes passed, homes connected.• What is HFC network.• Fundamentals of fiber optics.• Various losses in fiber link.• Fiber optic hardware, cables, and accessories. • Commonly used measurement techniques.• Use of multi-meter and signal level meter (dB meter).• Use of spectrum analyzer.• Loss calculations and signal level estimation in network segments.• Symbols used for Network hardware.• Hands on practice.• Field visits.• Theory and practical test.• Grade allocation.

Page 3: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

3

Alternating current (AC), Direct current (DC)

• There are two types of voltages you will be coming across in the network.

• AC voltage continuously changes with time as shown in the figure.

• The power supplied by electricity board has a voltage which is AC.

• The voltage measured by a meter on the three pin power socket (between 230 to 240 volts) is called R.M.S. (Root Mean Square) voltage which is sort of an ‘average’ voltage.

• http://www.yenka.com/freecontent/attachment.action?quick=14y&att=2937

Am

plitu

de

Time

Vo

ltage

AC voltage

Page 4: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

4

RMS explained

• For example: suppose the time samples are as shown in the diagram:  Values: 0 7 10 7 0 -7 -10 -7 Squares: 0,49,100,49,0,49,100,49

 Sum of squares = 396 Average of squares = 396/8 = almost 50 Square root ~ 7 7 = 0.7 x 10 (peak voltage)

 With more intervals the r.m.s. average turns out to be (peak value) / √2 = peak value/1.41 = 0.707 x peak value

325/1.41=230V RMS

Peak

RMS =

0.707 x peak

Page 5: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

5

Sine wave• A Sine wave is a periodic signal.• A clock pendulum is an example

of periodic motion. • A Sine wave is also a fundamental

signal. • All wave forms encountered in real

life are made of combination of number of sine waves.

• When signal goes through all possible variations and comes back to the next starting point, one cycle is completed.

• Number of cycles per second is called Frequency. It is measured in Hertz (Hz). Frequency of power is 50 Hz.

• As an example, starting from 6 a.m. today to 6 a.m. tomorrow is one day cycle.

• Similarly we can have a one year cycle.

1 cycle

1 cycle

Page 6: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

6

Voltages on 3 pin power socket

LN

E

L = Line terminal

N = Neutral terminal

E = Earth terminal

Front view of mains socket

230 V

A

ppro

x

230 V Approx

0 to

3 V

Color code for wires

Indian code

L = Red

N = Black

E = Green

European code

L = Brown

N = Blue

E = Green + white

Page 7: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

7

Top plug connections

• The picture shows Line, Neutral and Ground connections.

• There is a fuse in the line terminal for over current protection.

Back view of a top plug

Line

Neutral

Ground

Page 8: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

8

Batteries and DC voltage

• A source of DC voltage is a battery.• Batteries are used in conjunction with a UPS (Un

interruptible Power Supply unit) to maintain power in a network when electricity board power (Grid power) is unavailable due to a fault or load shedding.

• Batteries come in different voltages, sizes, shapes and in technologies.

• Batteries used in a CATV network can be of 12 or 24 volts, maintenance free or tubular which requires water topping periodically.

• The size of a battery depends on the time it can give a back up to maintain power in the event of power outage. It is specified in Ampere-Hours (AH). 65 and 100 AH batteries are most commonly used in a CATV network. Size of a battery will increase as AH rating increases.

Page 9: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

9

Batteries and DC voltage

• A Battery voltage is constant.• It does not change with time like

AC voltage.• Voltage, however, will drop when

batteries get discharged. • Batteries can be connected in

series to increase voltage or in parallel to increase AH.

• All electronic devices like lap top, mobile, TV, radio, music system work on DC voltage.

• We need a power adaptor for charging batteries of battery operated devices such as mobile or lap top.

• Devices working directly on 230 V AC have an internal power supply to convert AC voltage to DC voltage.

Positive terminal

Negative terminal

Battery symbol

Time

Vo

ltage

12 Volts

12 V, 65 AH battery

Series connection: 48 V, 65 AH Battery bank

Parallel connection: 24 V, 130 AH Battery bank

Battery discharge

Page 10: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

10

Converter/Inverter• A Converter converts AC voltage

to DC Voltage.• An Inverter converts DC voltage

to AC Voltage.• A UPS has both a converter and

an inverter built into it.• When grid power is available, it

will convert AC to DC and charge the batteries while powering the network also.

• When grid power fails, it will take DC from batteries and converts to AC to continue powering the network.

• Typically the batteries will give a back-up of 2 to 3 hours, depending on battery condition.

• One end of AC supply and the negative terminal of DC supply are normally grounded in a CATV network as shown.

• The co-axial cable outer conductor is grounded and acts as a return conductor.

Converter

AC voltage DC voltage

+

_

+

_

DC voltage AC voltage

Inverter

Page 11: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

11

Voltage, resistance, current, power and Ohm’s law

• Current in Amperes = Voltage in Volts/ Resistance in Ohms

I = V/R

• Power in watts = Voltage in Volts x Current in Amperes

P = V x IAlsoP = (I x R) x R = I2 x R

• From Ohm’s law, we can have following equations:

1. I = V/R2. V = I x R3. R = V/I4. P = V x I5. P = I2 x R6. P = V2/R

• 1 unit of electricity = 1 Kilowatt hours (KWH)

12 V batteryOpen circuit,

Very large resistance of air,

No current.

Short circuit,

Zero resistance

Heavy current

with sparks.

Load connected,

Current depends

on load in watts

If the bulb is of 30 watts, then

30 = 12 x I

I = 30/12 = 2.5 Amperes.

Current flowing through the bulb

is 2.5 Amps.

Page 12: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

12

Examples

• If V = 24 volts, R = 6 ohms then I = 24/6 (V/R) = 4 amps and P = (24)2/6 (V2/R) = 576/6 = 96 watts.

• If V = 24 volts, I = 4 amps then R = 24/4 (V/I) = 6 Ohms and P = 24 x 4 (V x I) = 96 watts.

• If I = 4 amps, R = 6 Ohms then V = 4 x 6 (I x R) = 24 volts and P = 42 x 6 ( I2 x R) = 16 x 6 = 96 watts.

Page 13: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

13

μa, ma, A, μV, mV, V, μW, mW, W

• I μA = I Amp x 1000,000• I mA = I Amp x 1000

• V μV = V Volt x 1000,000• V mV = V Volt x 1000

• P μW = P Watt x 1000,000• P mW = P Watt x 1000

• I Amp = I μA/1000,000• I Amp = I mA/1000

• V Volt = V μV/1000,000• V Volt = V mV/1000

• P Watt = P μW/1000,000• P Watt = P mw/1000

Page 14: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

14

Logarithm (Log), Antilogarithm (Antilog)

• 100 = 1 • 101 = 10• 102 = 100• 103 = 1000

• Log 1 = 0• Log 10 = 1• Log 100 = 2• Log 1000 = 3

• Antilog 0 = 1• Antilog 1 = 10• Antilog 2 = 100• Antilog 3 = 1000

Find log

Find anti-log

Page 15: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

15

Multiplication, division of numbers

• 100 x 10 = 1000• Log 100 = 2• Log 10 = 1• Sum of Logs = 2 + 1 = 3• Antilog 3 = 1000

Multiplication of two numbers is the sum of their Logs

• 1000/100 = 10

• Log 1000 = 3

• Log 100 = 2

• Subtraction of logs

3 – 2 = 1

• Antilog 1 = 10

Division of two numbers is the subtraction of their Logs

Page 16: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

16

Why Log, Antilog?

• There are 2 advantages in using logarithmic unit.• First, as we have seen, multiplication function gets

converted to addition and division function gets converted to subtraction.

• Because of this conversion, as you will see later, we can add gain and subtract losses when we are estimating signal level at different points in network segments. The whole process becomes very simple.

• Second, large numbers get transformed to small numbers e.g. log of 100,000 is 5. A 6 digit number has transformed to 1 digit.

• In a cable network one can encounter signal levels from 100 μV to 1000,000 μV (1V). When converted to dBμV, they are 40 dBμV to 120 dBμV – manageable numbers.

Page 17: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

17

Ratio and Decibel

• A ratio compares one number against another number.• If a son is weighing 40 Kg. and the father is weighing 80 Kg.

then the father is 80/40 = 2 times heavier than the son.• The number 2 does not indicate absolute weight of either

the son or the father (40 and 80 Kg).• If an amplifier input signal power is 10 mw and the

amplified output power is 100 mw then output power is 100/10 = 10 times higher than the input power.

• The number 10 does not indicate absolute power at either the input or the output (10 and 100 mw).

• Similarly Decibel is a comparison of two signal power levels.• This comparison can be against input power level or any

reference power level we may choose.

Page 18: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

18

Decibel (dB)

• 10 x Log Pout/Pin• If Pout is 100 mw and Pin is

10 mw• Then dB = 10 x Log 100/10

= 10 x Log 10= 10 x 1= 10 dB

• Pout is 10 dB greater than Pin

• Pin can also be a reference power and is generally 1 mw.

• 20 x Log Vout/Vin• If Vout is 100 mV and Vin is

10 mV• Then dB = 20 x Log 100/10

= 20 x Log 10= 20 x 1= 20 dB

• Vout is 20 dB greater than Vin

• Vin can also be a reference voltage and is generally 1 μV or 1 mV.

Decibel is the Log of ratio of Powers

Decibel is the Log of ratio of voltages across same value of resistor

Page 19: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

19

dBμV, dBmV, dBm

• dBμV indicates that our reference voltage is 1 μV .• Thus, 1000 μV is 20 Log(1000 μV/1 μV) = 20 Log 1000 = 20

x 3 = 60 dBμV.• 60 dBμV means that power delivered by 1000 μV in a

resistor is 60 dB greater than power delivered by 1 μV in the same resistor.

• dBmV indicates that our reference voltage is 1 mV.• Thus, to convert 1000 μV in to dBmV, first convert 1000 μV

to mV. • 1000 μV = 1 mV.• 20 Log 1 mV/1 mV = 20 Log 1 = 20 x 0 = 0 dBmV.• 0 dBmV means that that power delivered by 1mV (1000 μV)

in a resistor is 0 dB greater than power delivered by 1 mV in the same resistor.

• Thus we can say that 0 dBmV = 60 dBμV.

Page 20: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

20

dBmV dBμV dBm conversion

• dBμV = dBmV + 60• 30 dBmV = 90 dBμV• 55 dBmV = 115 dBμV• -10 dBmV = 50 dBμV• -25 dBmV = 35 dBμV

• dBmV = dBμV – 60• 60 dBμV = 0 dBmV• 75 dBμV = 15 dBmV• 40 dBμV = -20 dBmV• 55 dBμV = -5 dBmV

• Similarly we can prove that for a 75 Ohm system:

dBμV = dBm + 108.75dBm = dBμV – 108.75dBmV = dBm + 48.75dBm = dBmV – 48.75

Page 21: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

21

Passives: what do they do?

• Signal distribution on HFC network can be compared to water distribution in a city. We can say that our ultimate objective is to distribute water to all the households within certain pressure limits irrespective of their location.

• For this we need to have pipes of suitable diameters with valves and pressure regulators installed at correct locations.

• Each household needs only a small portion of water that is flowing in the main pipe.

• Similarly, each household requires only a small portion of a signal that is flowing in the trunk cable. Also the signal should be within certain strength (60 to 80 dBμV) irrespective of the locations of households.

• Clearly, we need some devices which will distribute and control the amount of signal to households. They are called passives.

Page 22: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

22

Passives

• Passives are used in the HFC distribution network to manipulate and distribute signal in the desired direction and proportion (power level).

• The word ‘Passive’ signifies that the passive devices do not require power for their functioning. As opposed to a ‘Passive’, an ‘Active’ device such as an amplifier requires power for it to work.

• Directional coupler, splitter, tap-off, power inserter, diplex filter, noise blocker, attenuator, terminator (Dummy load) are the passives used in a distribution network.

• Passives are made by using inductors, capacitors, resistors and R.F. transformers wound on ferrite material.

• A Passive is specified for the frequency range it can work for and losses between its various ports.

• All passives are designed for Input/Output impedance (Zo) of 75 Ohms.

Page 23: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

23

Directional coupler (DC)• A directional coupler (DC) divides

the signal unequally - major portion going to the output port, and only a small portion (design value) going to the coupled port.

• It couples a desired (by design) amount of signal to its coupled port from its input port.

• It comes in 8 or 12 dB coupling loss. An 8 dB coupler will have the signal level at the coupled port 8 dB lower than the input port level. This is called as ‘Tap loss‘ or ‘Coupling Loss’.

• Loss between Input and Output ports is called ‘Insertion loss’ or ‘Through loss’.

• Loss between Output port and Coupled port is called ‘Isolation’.

• Power can be made to pass through all the ports.

• SSP-7N, SSP-9N and SSP-12N are examples of a DC which give 7, 9 and 12 dB loss between IN and TAP ports.

SSP-7N

Page 24: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

24

Directional coupler as a signal combiner

• A directional coupler can also be used as a signal combiner.

• In the example shown, signal source1 is connected to the OUT port of a SSP-7N.

• Signal source2 is connected to the TAP port of the SSP-7N.

• Signal 1 will suffer insertion loss of 2 dB and signal2 will suffer tap loss of 7dB.

• After combining, signal2 will be 5dB lower than signal1.

• If you wish to have both, signal1 and signal2 levels to be the same, you need to have signal2 level at 105 dBμV so that at the IN port both signals will be 98 dBμV.

Signal

source 1

Signal

source 2

Signal 1

+ signal2 SSP-7N

100 dBμV

100 dBμV

98dBμV +

93dBμV

In

Tap

Out

Page 25: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

25

Use of a DC

• Typically, a DC is used at the output of a node or an amplifier or on a trunk.

• When the network needs to be split to cover two different areas and where one cable jump is long and the other is short, a DC is used.

Long cable jump

More signal

Short cable jump

8 or 12 dB less signal

8 or 12 dB DC

Amplifier

Page 26: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

26

Typical losses in a DC

• In all the Directional Couplers, as frequency increases, loss increases by 1 to 2 dB.

• As the DC value increases from 8 to 12 to 16, the insertion loss decreases.

Page 27: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

27

Splitters

• A splitter divides the signal equally. The input signal is divided in to 2 or 3 outputs.

• 2 way splitter has 4 dB loss between their input and output ports. This is called as ‘Splitting Loss’ or ‘Insertion Loss’.

• Loss between the Output ports is called ‘isolation’

• 3 way splitter has 2 ports with 8 dB loss while 1 port with 4 dB loss.

• Power can be made to pass through all the ports (outdoor type only).

• Indoor varieties can have 1 input and 2/4/6/8 output ports.

SSP-3N SSP-636N

Page 28: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

28

Use of a 2 way splitters

• Typically, a 2 way splitter is used at the output of a node or an amplifier or on a trunk.

• When the network needs to be split to cover two different areas and where both the cable jumps are approximately equal, a 2 way splitter is used.

Approx. 2 equal cable jump

2 way splitter

Amplifier

Page 29: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

29

Use of 3 way splitters

• Typically, a 3 way splitter is used at the output of a node or an amplifier or on a trunk.

• When the network needs to be split to cover three different areas and where two cable jumps are approximately equal and short while the third jump is long, a 3 way splitter is used.

Approx. 2 equal short cable jumps

3 way splitter

Amplifier

Long cable jump

Page 30: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

30

Typical losses in 2 way and 3 way splitters

• As the frequency increases, losses increase by 1 to 2 dB.

Page 31: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

31

Splitter used as combiner

• A splitter can work as a combiner, if it is used in reverse. It means that to make a 4 way combiner, one has to feed signals to the output ports of a 4 way splitter and get combined output in the ‘Input’ port.

Indoor 4 way splitter

Page 32: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

32

Tap-offs • The picture shows a 2 way tap diagram.

• A tap-off is a combination of a DC and a splitter.

• Signal loss between the Input port and the Output port is called ‘Insertion’ or ‘Through’ loss.

• Signal loss between Input and any tap port is called ‘Tap loss’. This loss is a designed loss and can be between 4 to 32 dB, in steps of 3 dB.

• We need different tap values because we need to feed equal amount of signal (60dBμV) to all the customers irrespective their location from the serving amplifier.

• Customers nearer the amplifier will be fed through high value taps while the ones away from the amplifier will be fed from low value taps.Symbol

Page 33: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

33

Tap-offs• Signal loss between Output port

and any tap port is called ‘Isolation’ and is greater than 20 dB.

• Signal loss between any two tap ports is called ‘Tap to tap isolation’ and is greater than 20 dB.

• The picture shows a 4 way tap-off diagram.

• 2way, 4way, 8way tap-offs come in Outdoor and Indoor variety.

• In the Outdoor type, there is power passing facility between In and Out ports. But usually there is no power passing on the tap ports. However, recently tap-offs with power passing facility on tap ports with protection fuses are available.

• Generally, there is no power passing facility on any of the ports in the Indoor type.

Symbol

Page 34: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

34

Indoor tap verities

Page 35: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

35

2, 4, 8 way 2, 4, 8 way outdoor tap-outdoor tap-offsoffs

Page 36: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

36

Typical losses in 2 way Tap-offs

• As the frequency increases, Insertion loss increases by 1 to 2 dB.

• As the tap value increases, Insertion loss decreases.

• 4 dB tap is a terminating tap – meaning the Output is terminated internally with 75 ohms and therefore, there is no external Output port.

Page 37: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

37

Typical losses in 4 way Tap-offs

• As the frequency increases, Insertion loss increases by 1 to 2 dB.

• As the tap value increases, Insertion loss decreases.

• 8 dB tap is a terminating tap.

Page 38: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

38

Typical losses in 8 way Tap-offs

• As the frequency increases, Insertion loss increases by 1 to 2 dB.

• As the tap value increases, Insertion loss decreases.

• 11 dB tap is a terminating tap.

• As the number of tap ports increase from 2 to 4 to 8, for the same tap value Insertion loss increases.

• A 14 dB 2 way tap has an insertion loss of 1.8 dB at 450 MHz, 4 way has 2.5 dB and 8 way has 4.1 dB.

Page 39: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

39

Line power inserter (LPI)

• Line power inserters are used for injecting 90 V A.C. voltage from a power supply into a trunk cable route to power a node and amplifiers. Signal and power are combined on such a cable. They normally come in outdoor type only.

UPS

230V

SSP-PIN

Page 40: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

40

Power/signal filter in LPI

AC VOLTAGE BLOCKING CAPACITOR

RF BLOCKING CHOKE

SIGNAL + AC 40~90 V

AC 40~90 V

RF

POWER

SIGNAL

Page 41: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

41

Rubber and wire mesh gaskets

• In all the outdoor passives there are two gaskets which fit between the unit and its base plate.

• Rubber gasket prevents rain water entry.• Wire mesh gasket prevents ingress/egress.• You should tighten base plate firmly by tightening the four

bolts.• Install tap-offs so that tap ports face the ground. This will

prevent rain water entry in to tap ports.• Tighten all check nuts to prevent rain water entry.

Page 42: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

42

Diplex filter

• Diplex filters are used to either combine or to separate the downstream (54 –860 MHz) and upstream (5 – 40 MHz) signals.

• In a 2 way network a diplex filter is installed at every Output of a node and at the Input and every Output of an amplifier.

• A Diplex filter is also required at the Headend if Co-ax network is directly fed from the Headend.

• The specification of the split of the diplex filter must match with that of your cable network.

Plug in units for node and amplifiers

Head end unit

Page 43: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

43

Attenuators (5 to 1000 MHz)

• Attenuators are used to introduce known loss in the network. They introduce almost uniform loss for all the frequencies from 5 to 1000 MHz.

• Many a times, signal level is too high for a network or a customer device. Therefore, we need to reduce the signal level by a known amount. This is done by an attenuator.

• Attenuators generally have F male interface at one end and F female interface at the other end.

• They come in values from 5 to 25 dB in 5 dB steps or from 3 dB 24 dB in 3 dB steps or from 1 dB to 20 dB in 1 dB step depending on the manufacturer and price.

• 5 to 1000 MHz – gives known uniform loss

Page 44: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

44

Return step attenuators (54 to 860 MHz pass)

• We use highest tap value for the customers located nearest to the amplifier, gradually reducing the value as we go away from the feeding amplifier.

• We do this to equalize the forward path signal (to 60 dBμV) to all the subscribers irrespective of their location from the feeding amplifier.

• In the return path also we need to equalize the return signals generated by customer devices (modem) to the same level (105 to 110 dBμV) irrespective of their location from the amplifier.

• A Return step attenuator introduces known amount loss only in the customer’s Return path, while introducing only 1 dB loss to the Forward path signals.

• 5 to 40 MHz – gives known uniform loss (5,10,15 and 20 dB)

• 54 to 860 MHz – gives 1 dB uniform loss

Page 45: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

45

High pass filter (54-860 MHz pass, 5-40 MHz block) • In a network catering to the TV

and Internet services, there will be some customers who are taking TV + Internet services and some taking only TV services.

• Only TV customers don’t require return path.

• Noise generated within the homes of only TV customers will enter in the network.

• Noise from many only TV homes will accumulate at a node degrading Return SNR.

• High pass filters are fitted on the tap ports connected to the drop cables going to the only TV customers, not requiring Return Path. These high pass filters (54 –860 MHz pass) block the noise generated in homes, not using the Return Path.

Page 46: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

46

Terminators (Dummy load, Loader)

• A Terminator is a 75 ohm resistor fitted in to a metallic casing which can be fitted on an out door casing or F female connector.

• All open ports of nodes, amplifiers and passives must be terminated with a Terminator to maintain network integrity.

• If the Terminators are not installed in the network, signal will get reflected from open ports and also noise ingress will take place.

Page 47: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

47

Homes passed and homes connected

• Homes passed tells us the number of homes (independent homes or apartments in a building) situated along a length of a cable.

• Homes passed indicates the number of customers which can be connected to a network for offering services.

• Homes passed indicates population density and the business potential of the area.

• It has a direct impact on the cost/connection.• If homes passed/km high then cost per connection is low and makes a

business case.• Homes connected tells us the number of homes actually connected to a

network. • In the example above, Homes passed is 94 and Home connected is 26.

8(3)

5(1)

6(2)

1(1)8(0) 7(5)

1(1) 8(0)20 (5)

30 (8)

Cable run

Page 48: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

48

What is HFC?

• HFC stands for hybrid fiber Co-ax.• HFC network is built using optical fibers, co-axial cables and

associated electronic hardware.• Optical fiber is the medium in which communication signals are

transmitted from one location to another in the form of light, guided through a thin fiber of glass.

• Co-axial cables, with their special construction, then guide the signal along the metallic conductors on the last mile to the destination.

Page 49: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

49

What is a network?

• A network is the way fibers, co-axial cables and the associated hardware pieces are connected.

• The main considerations for fiber network are:– Availability of fiber (owned or leased).– Fiber susceptibility to breakage. – Reliability and redundancy requirement.– Cost of laying a fiber cable or leasing Vs business potential.– Signal format – whether IP optical or Amplitude Modulated

optical.– Distances to be covered.– Back-up power arrangements.

• The main considerations for Co-ax network are signal integrity in the last mile i.e. considerations for noise (C/N) and distortion components (CSO/CTB/XMod) and power outages.

• For this reason cascade of amplifiers is limited to 3 or 4 and UPS power back-up is always provided.

Page 50: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

50

Why HFC?

• Prior to the emergence of fiber optic technology, networks were built using only co-ax cables.

• However, because of unique properties of optical fiber, it is coming ever nearer to home.

• It is the best combination for signal delivery in terms of cost, reach, reliability and bandwidth.

• Because fiber introduces very low loss to signal, large distances (20 to 50 km) are covered using a fiber to bring signal to a distribution point (Node).

• From the node signal is then distributed on co-ax cables to homes covering a radius of 1 km.

Page 51: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

51

Basic fundas of fiber optics

• To understand fiber fundas, we need to go back to school days.

• Remember pictures of bent straw in a water filled glass or mirage in a desert in your physics books?

• When a light ray passes from one medium to another having different densities (water and air), it changes its path.

• Density of material is indicated by refractive index – denoted as ‘n’.

Page 52: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

52

• Refractive index ‘n’ of a material is: speed of light in vacuum

speed of light in the material

• Light has highest speed in vacuum and slows down in other medium such as glass, plastic, water. The Refractive Index for all these materials is greater than 1.

• Water has R.I. of 1.3 and glass has R.I. of 1.5 approx.• When light travels from thick (Higher ‘n’ such as water) to thin

(Lower ‘n’ such as air) or vice versa, its path will bend causing an illusion similar to the ‘bent’ stick which you learnt in school physics.

Page 53: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

53

Total internal reflection• Optical fiber has a core and cladding.• The core is made of higher Refractive

Index than the cladding (outer).• Light ray CC’ enters the cladding after

bending.• Light ray BB’ travels along the

boundary (critical angle).• Light ray AA’ is reflected internally in

the core.• This is because entry angles at the

boundary are progressively increased.

• The core and cladding are usually very pure fused silica glass covered by a plastic coating, called ‘Buffer’.

• Core and cladding are not physically separable and the boundary can’t be identified.

How light travels within a fiber

Page 54: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

54

Frequency, period, wavelength, micrometer, nanometer

• Frequency (f) is:Number of cycles/second.Example: Power frequency is 50cycles/second (Hz), Human audio frequency response range is 20 to 20,000 cycles/second (Hz).

• Period (T) is:Time taken to complete one cycle. T= 1/f

• Wavelength (λ) is:Distance traveled by signal in a time of period T. λ = C/fwhere C is speed of light in a medium in meters/second.Light signal is normally characterized in wavelength which is easy to write and talk about. Frequency characterization results in awkward and lengthy numbers.

• Micrometer = Micron = μM = Meter/1000,000• Nanometer = nm = Meter/1000,000,000

Page 55: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

55

Multimode Vs Single mode fiber.

• There are two basic types of optical fiber – multimode (used for short distance in LAN) and single mode (used for long distance in CATV / Telco).

• Multimode fiber means that light can travel many different paths (called Modes) through the core of the fiber, entering and leaving the fiber at various angles.

• In single mode, the core size is reduced (8 to 10 microns) causing all the light to travel in one mode (straight line).

Page 56: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

56

n2

n1

Cladding

Core

n2

n1

Cladding

Core

Multi-Mode Single-Mode

Modes of light Many One

Distance Short (meters) Long (km)

Bandwidth Low High

Typical Application

Access Metro, Core, CATV

• Multi-Mode: supports hundreds paths for light.

• Single-Mode: supports a single path for light

Page 57: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

57

Multimode Dispersion

• Light rays are transmitted from the source at a variety of angles and arrive at the receiver at different times, thereby creating distortion at the output. This sets a limit on the distance covered in Multimode fiber.

Source www.cisco.com

Page 58: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

58

1310 nm Vs 1550 nm

• These are the two most commonly used wavelengths in optical communication.

• 1310 nm wavelength has a loss of 0.35 dB/km. It is used up to a distance of 30 km.

• 1550 nm wavelength has a loss of 0.23 dB/km. It is used up to a distance of 50 km, because of lower loss.

• Single mode G.652 fiber (ITU) is the most widely deployed (90%) fiber in the world which accepts both 1310 and 1550 nm wavelengths.

Page 59: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

59

• Apart from losses in the fiber, there are losses in splices and connectors.

• Typically, splice loss is 0.05 dB/splice and connector loss is 0.25 dB/connector.

• There is also sag loss if fiber is laid overhead. Sag loss is equivalent of adding 4% to the fiber length.

• Loss also occurs if fiber is sharply bent, depending on the bending radius.

• The bending loss is about 3 times for 1550 nm wavelength as compared to 1310 nm for the same bending radius.

• One needs to calculate and sum up all these losses to arrive at a link budget.

Other losses in a fiber link

Page 60: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

60

Re-generation

• Using 1310 nm wavelength, to cover more distance, one has to do re-generation.

• This means light signal is converted to electrical signal using an optical receiver and then again converted to light signal using another optical transmitter.

• However, this process adds 3 dB noise and one should not do more than two re-generations.

RF

RF

Light Light

Tx TxRx

Re-generation

Page 61: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

61

Optical amplifier

• For 1550 nm wavelength, re-generation is not necessary to increase distance.

• One can use optical amplifiers (also called EDFA – Erbium Doped Fiber Amplifier).

• EDFA amplifies weak light signal in to powerful one to cover further distance.

• 40 different wavelengths, from 1528 to 1561 nm, each carrying independent information can be multiplexed together on a single fiber and can be amplified by EDFA. This is known a Dense Wave length Division Multiplexing (DWDM).

• However, one shouldn’t have more than two EDFAs in cascade because of noise consideration.

RF Light

Tx EDFALight

Page 62: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

62

Multiplexer / De-multiplexer

Wavelengths separated into individual ITU Specific lambdas

Wavelengths

Wavelength Multiplexed Signals

DWDMMux DWDM

Demux

Wavelength Multiplexed Amplified Signals

EDFA

EDFA accepts optical power anywhere from 0 to 6 dBm and delivers optical output power between 16 to 23 dBm depending on the model.

Page 63: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

63

Fiber cable construction

• Loose tube construction• Single fiber/tube

Page 64: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

64

Loose tube construction, multiple fibers/tube

Page 65: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

65

Fiber protection

• Ultra violate curable lacquer coat at the time drawing• Extruded colored buffer coat• Gel• Aramid yarn • Kevlar coating• Outer plastic jacket with embedded strength members.• Steel wire armor in case of UG cable

Page 66: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

66

Additional advantages of fiber

• Cable without steel armor is immune to high voltage.• No effect of external electromagnetic interference.• Almost no effect of moisture.• Almost no effect of temperature variation.• Light weight.• Very large bandwidth with DWDM.• Very affordable at today’s prices.

Page 67: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

67

Introduction to hardware

• The optical fiber link is made of:• A light source (Laser: Light Amplification by Simulated

Emission of Radiation) with support electronics, to receive and convert electrical information to optical, using a connector and alignment mechanism.

• Fiber with connectors / splices.• Photo detector at the receiving end – which converts incoming

light back to electrical signal, producing a copy of the original electrical input.

• The light source and the photo detector with necessary support electronics are called as transmitter and receiver.

Page 68: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

68

Transmitters:• A transmitter takes electrical input and converts it into light

output.• The electrical input is RF signal from CMTS and video Head

End.• It sits in at HE and/or Hub and can come as a stand alone

19”, 1U unit or can come as a plug-in unit to fit into a 3U chassis. Multiple transmitters and RPR can fit into a chassis having a common power supply.

• It comes in different wave lengths, 1310 and 1550 nm being the most common.

• It can come in ITU defined DWDM wavelengths too!• It comes in different standard steps of power i.e. 3, 6, 8, 10,

12, 13, 15 and 16 dBm.• First, we need to decide the wavelength, then calculate the

link budget and decide transmitter power.

Page 69: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

69

• Transmitter power can’t be increased later.• Transmitter power is expensive, cost increasing with power.

Therefore, correct link budget is necessary. • 1550 transmitter is more expensive than 1310.• 1550 transmitter comes in two verities:

Direct modulationExternal modulation – these are more expensive

• DFB (Distributed Feed Back) laser is used in the (Forward) transmitters because of higher BW and power.

Page 70: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

70

Node:• A node receives light signal through a fiber and a Forward

receiver in the node converts it into an electrical signal (RF).

• Optical input power to node should be between -2 to +1 dBm

• The RF signal is further amplified and sent on to a co-ax network.

• Return RF signal coming from modems in homes enters a node, is amplified and converted in to a light signal using a Return transmitter.

• Return transmitter power may be -4, 0 or +3 dBm.• The return laser used is mostly Fabry-Perot (FP) but can be

DFB in 0 and +3dBm power. • Choice of type and power of a laser is left to the user. It is

normally a plug-in device.• DFB laser is more expensive than FP laser.

Page 71: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

71

Diplex filter

Page 72: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

72

• Thus a node has one incoming (Forward) and one outgoing fiber (Return) and may have 2 or 3 RF cables (500 series) going out to a co-ax network.

• A node normally sits securely in a kiosk.• A kiosk also accommodates battery bank, UPS and Raw

power/UPS power modems.• These modems indicate the failure of Raw power and how

long the UPS back-up is ON, to a person in POP.• 90V power from UPS/Power supply is also inserted in to a

node to power the node and amplifiers in the co-ax network via 500 series cables – which also carries Forward and Return RF signals.

Page 73: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

73

Return Path Receiver (RPR)

• A RPR, sitting in at HE and/or Hub receives light signal from a node and converts it to RF signal.

• This Return RF signal then goes to Return port of a CMTS, thus establishing two way communication between CMTS and modems.

• Normally, RF Return signals of 2 or 3 nodes are combined before entering in to a Return port of CMTS.

Page 74: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

74

Forward fiber

Return fiber

Node

To/From Co-ax network

CMTS

RPR

TX

Forward RF

ReturnRF

RPR

Co-ax network

From another node

HE/Hub Field

Ana+Digi TV

Page 75: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

75

Couplers

• Couplers are used to split optical power in to two parts to feed to nodes sitting at two different locations in the field.

• Power is split in such a way that a node sitting at a larger distance gets more power compared to the node sitting nearer.

• Couplers can sit at POP (HE) as shown:

Head end splitting

Requires more number of fibers, but more secure.

Page 76: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

76

• Or they can sit in the field as shown above.• Couplers come in standard split from 50:50 to 95:5.• These numbers indicate the percentage of input power going into

two output legs of a coupler.• 60:40 means that 60% of input power goes to one leg and 40%

goes to other.• The fibers will have stickers to indicate which is 60% and which is

40%.

Field split

Requires only one fiber, but not so secure.

Page 77: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

77

Fiber management system (FMS)

• FMS is a metal cabinet in which following facilities are incorporated:

1. Openings at top and bottom for incoming and outgoing fiber cables.

2. Secure clamping of cables.3. Splice trays.4. Patch panels.5. Provision for winding extra patch cords.6. LabelingAll fiber cables and fibers coming from equipment terminate on

patch panel. Patch cords are used to make optical connections.

This arrangement introduces order, clarity and flexibility in connections. Changing connection can be done easily and quickly by interchanging connection on the patch panel using patch cords.

Page 78: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

78FMS

Patch panel

Patch cord

Page 79: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

79

Connectors

• SC/APC – Snap Connector/Angled Physical Contact – Push type - Green color

• This is used almost on all equipment e.g. Tx, RPR, node.

• SC/PC - Snap Connector/ Physical Contact – Push type – Blue color

• This is used for data equipment like media converters, switches.

• FC/APC – Ferrule Connector/Angled Physical Contact - Push and thread tight type – Green color

• This is used on power meters and OTDR

Page 80: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

80

Patch cord, pigtail

• Patch cord (mostly yellow color):This is a flexible, protected single strand of fiber with connectors fitted at both ends, for indoor use.It can be purchased in different standard lengths like 3, 10,15 meters with a choice of connectors.

• Pigtail:When we cut a patch cord into two, we get two pig tails. A pig tail has a connector at one end and bare fiber at the other end.

Note that G.652 fiber, nodes, couplers, connectors, patch cords and pigtails support both 1310 and 1550 nm wavelengths.

Page 81: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

81

Splice enclosure

• Splice enclosure:When a fiber cable is cut unintentionally or intentionally to take out some fibers for connection, all fibers are exposed.All the fibers have to be spliced to establish the connectivity. Fibers being fragile, splices and bare fibers are neatly put in a splice enclosure.

• They come in various sizes depending how many splices can be accommodated.

Page 82: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

82

Splice enclosures

Optical coupler

Page 83: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

83

Power meter, OTDR

• Power meter is used for measuring optical power in dBm for both 1310 and 1550 nm. It is used for confirming estimated power and as a tool for fault finding. It costs few thousands of Rupees

• Optical Time Domain Reflectometer is a diagnostic tool with a LCD screen to locate the distance of fiber break, loss along the length of cable, reflection and poor connectorization.This is an expensive instrument, costing few lacs of Rupees.

Page 85: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

85

Typical HFC architecture

• Signal originates from the Headend. • The ring connecting the Regional HE and Hub is the core

network. It will have fiber redundancy.• If the core network is within a metro, covering distances

within 40 k. m. the signal format may be IP optical/STM or A.M.optical.

• If core network is encompassing multiple cities, the signal format will be IP optical/STM and bandwidth is taken from the carriers.

• A hub caters to an area of up to 5 to 40 k.m. radius.• It is possible to do local program insertion at the hub level.• The network beyond the hub to homes is called Access

network.

Page 86: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

86

Star architecture

Fibers going from HE to every node. Local channel insertion not possible. No fiber redundancy. High fiber requirement.

Page 87: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

87

Double star architecture

Single fiber to a hub. Re-generation at hub. Local program insertion possible. No redundancy.

Page 88: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

88

Ring architecture

Full automatic redundancy. High fiber requirement.

Page 89: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

89

Shared ring/star architecture

This architecture provides for auto redundancy, local program insertion using minimum fibers.

Page 90: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

90

POWER

MB AMP.

BLE AMP.

Node Kiosk

Return fiber

Forward fiber

To other amplifiers

Spacing between

amplifiers 300 to 325

Meters

Access network

Page 91: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

91

Use of a multi-meter• A multi meter is used for

measuring 1) AC voltage 2) DC voltage 3) DC current 3) Resistance 4) Continuity of a conductor.

• Black lead always connected to COM terminal of a meter.

• When measuring AC voltage, DC voltage, resistance and continuity the Red lead is connected to VΩmA terminal of a meter.

• When measuring DC current, shift the Red lead to 15A DC.

• Make sure that when measuring voltage the Red lead is not in the 15A DC. It may blow a fuse in the meter.

• When doing measurement, always connect Black lead to –ve of a DC source and neutral of an AC source.

• While measuring continuity, there will be an audible tone if continuity exists in the conductor being measured.

AC voltageDC

voltage

Resistance

DC current

Continuity

Page 92: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

92

Measurements – signal level meter (SLM)

• A TV signal level meter (SLM) measures signal levels at desired points in the network. It is an inexpensive instrument for daily use for every field technician.

• It gives signal level in dBμV or in dBmV or in dBm.

• One can select a channel plan, edit it, select a channel type whether analog or digital.

• Measurements are possible in 4 modes – 1) level 2) scan 3) spectrum mode 4)Tilt mode.

Page 93: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

93

SLM

• In level mode one can select channel by its number or by frequency. This is a mode most frequently used. The refresh time is short in this mode because meter does measurement of only one channel.

• Scan mode shows a bar graph of all channels and is most useful when you want find out variations in channel levels at one go. Also my moving marker you can go from one channel to another channel very quickly. The refresh time is long because meter does measurement of all the channels.

• Spectrum mode is useful for fault finding. In particular for finding out any unwanted signal generated within the HFC plant or aerial signal that is picked up. Refresh time increases with increase in the span selected.

• In Tilt mode one can configure lowest (E3), highest (U69) and some channels in between for tilt measurement. This measurement shows a bar graph of configured channels. Since lowest and highest channels are selected, it measures and displays the tilt directly. This is useful while doing alignment of amplifiers.

Page 94: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

94

Measurements – spectrum analyzer• A spectrum analyzer gives a

graph of signal amplitude (Y axis) in frequency domain (X axis).

• It is a precision instrument normally used for accurate measurements and difficult to find faults at the HE or in the field.

• Measurements that are normally done are level, C/N, CTB, CSO and interference etc.

• It comes with a tracking generator as an option. With this option, we can do response measurement of cables, amplifiers, taps, splitters etc.

• Analyzer tailor made for CATV requirements are also available, making measurements very quick and accurate.

Page 95: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

95

Loss calculations and signal level estimation

100 dBμV

@ 860 MHz

DC8

30M/500 series

40M/500 series

50M/500 series 60M/500 series 70M/500 series

Find out signal reaching the home at 860 MHz?

Loss in 30M 500 series cable = 7.7x0.3 = 2.3 dB

Loss in 40M 500 series cable = 7.7x0.4 = 3.1 dB

Loss in 50M 500 series cable = 7.7x0.5 = 3.9 dB

Loss in 60M 500 series cable = 7.7x0.6 = 4.6 dB

Loss in 70M 500 series cable = 7.7x0.7 = 5.4 dB

Loss in 30M RG6 cable = 20x0.3 = 6.0 dB

Total cable loss = 2.3+3.1+3.9+4.6+5.4 +6.0 =25.3 dB

30M/RG6

14 dB21dB

11dB

Page 96: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

96

Loss calculations and signal level estimation

100 dBμV

@ 860 MHz

DC8

30M/500 series

40M/500 series

50M/500 series 60M/500 series 70M/500 series

Passive loss:

DC8, tap loss = 8.5 dB

2 way splitter, insertion loss = 5.0 dB

8 way tap, insertion loss = 2.4 dB

4 way tap, insertion loss = 3.0 dB

2 way tap, tap loss = 11.0 dB

Total passive loss = 8.5+5.0+2.4+3.0+11.0 = 29.9 dB

30M/RG6

14 dB20dB

11dB

Page 97: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

97

Loss calculations and signal level estimation

100 dBμV

@ 860 MHz

DC8

30M/500 series

40M/500 series

50M/500 series 60M/500 series 70M/500 series

Cable loss + Passive loss:

25.3 + 29.9 = 55.2 dB

Signal level at the home = 100 – 55.2 = 44.8 dBμV

30M/RG6

14 dB20dB

11dB44.8 dBμV

Page 98: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

98

Symbols

Directional coupler/one way tap

2 way tap

4 way tap

8 way tap

Terminating tap

Page 99: 1 HFC11.0 Fundamentals of HFC. 2 Agenda Basics – AC, DC, Ohm’s law, Units and measurements. Log, Antilog, why use them loss, gain, power level units?

99

Symbols

2 way splitter

3 way splitter unbalanced

Dot shows high output leg

Headend

Primary Hub

LE with

Return

MB with

Return

Optical node

Optical

transmitter