1 jim thomas - lbl changes to the inner sector strongback to accommodate a wall between the inner...
TRANSCRIPT
![Page 1: 1 Jim Thomas - LBL Changes to the Inner Sector Strongback to accommodate a wall between the inner and outer sectors (and a 2 nd wall at the innermost edge](https://reader035.vdocuments.net/reader035/viewer/2022062409/5697c02e1a28abf838cda435/html5/thumbnails/1.jpg)
1Jim Thomas - LBL
Changes to the Inner Sector Strongback to accommodate a wall
between the inner and outer sectors(and a 2nd wall at the innermost edge of the inner sector)
Jim Thomas
10/15/2015
![Page 2: 1 Jim Thomas - LBL Changes to the Inner Sector Strongback to accommodate a wall between the inner and outer sectors (and a 2 nd wall at the innermost edge](https://reader035.vdocuments.net/reader035/viewer/2022062409/5697c02e1a28abf838cda435/html5/thumbnails/2.jpg)
2Jim Thomas - LBL
Top View of an Inner & Outer Sector at STAR
60 cm
190 cm
• 24 sectors (12 on a side)
• Large pads good dE/dx resolution in the Outer sector
• Small pads for good two track resolution in the inner sector
Grid Coverage is not complete
![Page 3: 1 Jim Thomas - LBL Changes to the Inner Sector Strongback to accommodate a wall between the inner and outer sectors (and a 2 nd wall at the innermost edge](https://reader035.vdocuments.net/reader035/viewer/2022062409/5697c02e1a28abf838cda435/html5/thumbnails/3.jpg)
3Jim Thomas - LBL
Proposal to solve the “Grid Leak” requires a wall
• Put a wall between the inner and outer sectors, mount to the top edge of the inner sector
• Also need another wall at the bottom edge of the inner sector• Wall is 1/16” mm thick Printed Circuit Board with Cu on both sides• Thus, two walls with a wire to feed voltage to both walls
DRAFT : Not to Scale Not for Construction
![Page 4: 1 Jim Thomas - LBL Changes to the Inner Sector Strongback to accommodate a wall between the inner and outer sectors (and a 2 nd wall at the innermost edge](https://reader035.vdocuments.net/reader035/viewer/2022062409/5697c02e1a28abf838cda435/html5/thumbnails/4.jpg)
4Jim Thomas - LBL
Two walls required – same style and technology
• hi
![Page 5: 1 Jim Thomas - LBL Changes to the Inner Sector Strongback to accommodate a wall between the inner and outer sectors (and a 2 nd wall at the innermost edge](https://reader035.vdocuments.net/reader035/viewer/2022062409/5697c02e1a28abf838cda435/html5/thumbnails/5.jpg)
5Jim Thomas - LBL
Conceptual Design of Notch to hold PCB Walls
DRAFT : Not to Scale Not for Construction(dimensions are inches)
• ¾” by 0.070” notch is for mounting PCB board as the wall
• 1/8” deep auxillary channel is to carry up to 3 wires (1000V, 18 AWG)
![Page 6: 1 Jim Thomas - LBL Changes to the Inner Sector Strongback to accommodate a wall between the inner and outer sectors (and a 2 nd wall at the innermost edge](https://reader035.vdocuments.net/reader035/viewer/2022062409/5697c02e1a28abf838cda435/html5/thumbnails/6.jpg)
6Jim Thomas - LBL
End View detail – note access path for wires
Pad Plane Here
Ribs Here
Before adding notch
![Page 7: 1 Jim Thomas - LBL Changes to the Inner Sector Strongback to accommodate a wall between the inner and outer sectors (and a 2 nd wall at the innermost edge](https://reader035.vdocuments.net/reader035/viewer/2022062409/5697c02e1a28abf838cda435/html5/thumbnails/7.jpg)
7Jim Thomas - LBL
Backup Slides
![Page 8: 1 Jim Thomas - LBL Changes to the Inner Sector Strongback to accommodate a wall between the inner and outer sectors (and a 2 nd wall at the innermost edge](https://reader035.vdocuments.net/reader035/viewer/2022062409/5697c02e1a28abf838cda435/html5/thumbnails/8.jpg)
8Jim Thomas - LBL
Dimensions - recap
• Notches & Wall are on the same side of the sector as the PadPlane
• Wall will be 1/16” G10 and should fit comfortably into 0.070” notch
• Notch is full width at upper end and lower end of inner sector– Sector is 24.5” full width at top, 9.85” full width at bottom
• 0.070” deep• 0.750” tall
• ¼” wide channel for wires, 1/8” deep – Wires go under the wall– So channel is 0.125” deeper than 0.070” cut for wall– Note addition of access path for wires … to go from side of sector, to
backside of the wall
• Two rows of screws, first row is 1/8” below padplane surface, etc. – Use #6 screws, 2 inches apart, counter sunk into G10 wall
![Page 9: 1 Jim Thomas - LBL Changes to the Inner Sector Strongback to accommodate a wall between the inner and outer sectors (and a 2 nd wall at the innermost edge](https://reader035.vdocuments.net/reader035/viewer/2022062409/5697c02e1a28abf838cda435/html5/thumbnails/9.jpg)
9Jim Thomas - LBL
Inner sector … upper end
• A portion of the (old) Inner Sector near the Inner – Outer sector boundary– In other words, the top edge of the inner sector
Wall goes here
![Page 10: 1 Jim Thomas - LBL Changes to the Inner Sector Strongback to accommodate a wall between the inner and outer sectors (and a 2 nd wall at the innermost edge](https://reader035.vdocuments.net/reader035/viewer/2022062409/5697c02e1a28abf838cda435/html5/thumbnails/10.jpg)
10Jim Thomas - LBL
Inner Sector … lower end
• Sometimes we call this the inner-inner grid leak– It requires an inner-inner solution
• We can build a wall that is very similar to the wall that goes between the inner and outer sectors
– The only difference is the length of the wall• Top Edge Full width is 24.5”, Bottom Edge Full width is 9.85”
Wall goes here
![Page 11: 1 Jim Thomas - LBL Changes to the Inner Sector Strongback to accommodate a wall between the inner and outer sectors (and a 2 nd wall at the innermost edge](https://reader035.vdocuments.net/reader035/viewer/2022062409/5697c02e1a28abf838cda435/html5/thumbnails/11.jpg)
11Jim Thomas - LBL
Conceptual Design of Notch to hold PCB Walls
0.750”
0.070”
0.250”
0.250”
0.250”
0.125”
DRAFT : Not to Scale Not for Construction(dimensions are inches)
• ¾” by 0.070” notch is for mounting PCB board as the wall
• 1/8” deep auxillary channel is to carry up to 3 wires (1000V, 18 AWG)
![Page 12: 1 Jim Thomas - LBL Changes to the Inner Sector Strongback to accommodate a wall between the inner and outer sectors (and a 2 nd wall at the innermost edge](https://reader035.vdocuments.net/reader035/viewer/2022062409/5697c02e1a28abf838cda435/html5/thumbnails/12.jpg)
12Jim Thomas - LBL
End View detail – note access path for wires
Pad Plane Here
Ribs Here
Before adding notch
0.250”
0.250”
0.250”
0.25
0”
0.25 Radius0.750” #6-32 every 2”