1. LOW COST 2. SIMPLE 3. EFFICIENT. EER. Energy Efficiency Ratio =. Cooling Capacity in Btu / Hr. Power Consumption in Watts. Mechanical Subcooling. Moving cooling load from the main compressor to the subcooling compressor increases efficiency. R410A - A New Opportunity. - PowerPoint PPT PresentationTRANSCRIPT
1. LOW COST 2. SIMPLE 3. EFFICIENT
EER
• Energy Efficiency Ratio =
Cooling Capacity in Btu / Hr
Power Consumption in Watts
Mechanical Subcooling• Moving cooling
load from the main compressor to the subcooling compressor increases efficiency.
R410A - A New Opportunity
• R410A = compressor EERs of 14 to16
• Not a refrigerant for medium or low temperature refrigeration.
• Line sizes must stay small due to high pressures, which points toward a one on one design.
R410A Subcooling Medium Temp
• R410A EER = 16.0
• R404A EER = 7.1
• Transferred
BTUs
• 200% Efficiency
Gain
Big Compressor
Small Comp
R410A Subcooling Low Temp
• R410A EER = 16.0
• R404A EER = 3.7
• Transferred
BTUs
• 400% Efficiency
Gain
Big Compressor
Small Comp
R410A
R404A
The ETL Tests
ETL is the established authority on refrigeration performance testing.
Medium Temp
The ETL Tests
ETL is the established authority on refrigeration performance testing.
Low Temp
The ETL Report
Download
From
BMIL.COM
Distributed
Systems
Smaller Refrigera
nt Charge
Distributed Systems
Smaller Refriger
ant Charge
Frio Verde and R22 to R404A conversions.
1. Some stores are converting R22 to R404A.
2. Standard R404A has 66% more mass flow than R22 for the same heat transfer.
3. The mass flow increase calls for suction line re-piping with standard R404A systems.
4. Frio Verde R404A has the same mass flow as R22 due to subcooling at 50 ºF to 60 Deg ºF.
5. Frio Verde saves $30k to $40k of re-piping cost on a 50,000 sq ft. supermarket conversion.