1 luca stanco - infn padova krakow, 28 september 1999 setup reminder status of the limited streamer...
TRANSCRIPT
![Page 1: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/1.jpg)
1 Luca Stanco - INFN Padova
Luca Stanco - INFN PadovaKrakow, 28 September 1999
Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up etc.
![Page 2: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/2.jpg)
2 Luca Stanco - INFN Padova
Elettrons
Protons
RM
UO
N
BMUON
![Page 3: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/3.jpg)
3 Luca Stanco - INFN Padova
~ 3 600 LSTs (with lenght from 0.7 to 10.2 m)
~ 43 000 8-bit analog channels ~ 29 000 digital channels
Area detector > 2 000 m2
Technical Coordinator: Riccardo Brugnera
Web-master: Vincenzo Chiochia
Resolution: 1 mm in the “strip” view 3 mm in the “wire” view
![Page 4: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/4.jpg)
4 Luca Stanco - INFN Padova
Mortality...
year BMUI BMUO RMUI RMUO Total Ch72
1994 78 59 41 23 201 34
1995 - - - - - -
1996 78 59 42 23 202 36
1997 79 59 45 33 216 25
1998 81 66 50 41 238 25
1999 81/708 66/1502 50/480 41/704 238/3394 25/184
plus ~ 68 LST in trip for 10-40% of time
plus ~ 10 LST in trip for 10-40% of time
![Page 5: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/5.jpg)
5 Luca Stanco - INFN Padova
DeadDead LSTLST’s are normallynormally switched offswitched off
SimulationSimulation in the in the Monte CarloMonte Carlo via an via an EAZEEAZE job: job:
to evaluate efficiencyefficiency dependence (small effect: 5%)
effi
cien
cy
BMUON
RMUON
- MC ideal- - MC with dead LST
![Page 6: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/6.jpg)
6 Luca Stanco - INFN Padova
Slot 8: Elastic Slot 10: Inner BMUONBMUONSlot 11: Inner RMUONRMUONSlot 14: Outer BMUONBMUONSlot 15: Outer RMUONRMUON
• GLOMU• GLOEXO
InnerOuter
![Page 7: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/7.jpg)
7 Luca Stanco - INFN Padova
rates...
1 b for L = 10*1030 10 Hz (most of the runs)
![Page 8: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/8.jpg)
8 Luca Stanco - INFN Padova
with INNER chambers
and with ISOMU: Calorimeter regions
![Page 9: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/9.jpg)
9 Luca Stanco - INFN Padova
rates
INNER
OUTER
![Page 10: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/10.jpg)
10 Luca Stanco - INFN Padova
GLOMU rates
30 nb for L = 10*1030 0.03 Hz
cosmics
![Page 11: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/11.jpg)
11 Luca Stanco - INFN Padova
independent setup: efficiency vs HV
working value to reduce trips
![Page 12: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/12.jpg)
12 Luca Stanco - INFN Padova
HV: 4700
HV: 4550
include inefficiency factor on single LSTin the Monte Carlo (15%)
100%
100%
88%
75%
![Page 13: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/13.jpg)
13 Luca Stanco - INFN Padova
- MC ideal- - MC with dead LST and 15% factor for HV
effi
cien
cy
BMUON
RMUON
15% inefficiency coherent with analysis of single track segment !
![Page 14: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/14.jpg)
14 Luca Stanco - INFN Padova
Check efficiencyefficiency with DATADATA themselves !Two independent analysis on 2 track +- clean events
(3 different set of events, depending of the trigger)
BMUON
SET 1
SET 2
![Page 15: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/15.jpg)
15 Luca Stanco - INFN Padova
… much more in Alessandro Bertolin’ talk
this afternoon
Monte Carlo is off of an overall factor !
A few investigations performed.A few investigations performed.Not yet found out the reason...Not yet found out the reason...
![Page 16: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/16.jpg)
16 Luca Stanco - INFN Padova
VMS computer for DAQ• patch from DEC (and spare VAX from DELPHI available)
• upgrade on going ...
Slow Control with OS9 (version 2.3 NOT good)• manual patch (bring time back, uff !) …• upgrade to 3.03 ?
![Page 17: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/17.jpg)
17 Luca Stanco - INFN Padova
Time for AbortingAborting as function of RunRun ...
problem while Aborting Run ?
![Page 18: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/18.jpg)
18 Luca Stanco - INFN Padova
Distribution of Time for Aborting Aborting ...
for last positron runs...
![Page 19: 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up](https://reader036.vdocuments.net/reader036/viewer/2022081602/5514593a5503462d4e8b54ff/html5/thumbnails/19.jpg)
19 Luca Stanco - INFN Padova
• Good general behaviour of the detector
• Triggers under control
• Efficiency studies on the way on
• Few upgrades needed for next millenium
Good perspectives for next millenium Runs