Objective

• Finish with PM measurements

• Discuss Friday’s filed measurements

1

Page 2: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

ASHRAE Transaction 2004

Properties

Page 3: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

Properties and sources

ASHRAE Transaction 2004

Page 4: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

Optical instruments Mie Theory for Scattering

• Forward-scattering and back-scattering• Functions of (λ, θ, dp, Vp)

• Often see size parameter, α = πd/λ

Page 5: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1
Page 6: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

MEASURE MASS CONCENTRATION •Photometers

• Typically relative instruments• Sensitive to particle speed

•Nephelometer• Measure scattering for aerosol sample (~ 1L) over wide

range of angles ()• Particle density is function of the light reflected into the detector

– Scatered light depends on properties of the particles such as their shape, color, and reflectivity.

• Determines mass concentration much more accurately than photometer

• Often calibrated to single particle composition

Light scattering methods (Detection Sensor)

Page 7: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

Condensation Nuclei Counter (CNC)

PARTICLE COUNTER •Subject aerosol stream to alcohol (or water) vapor•Cool air stream to cause condensation•Count particles with an optical particle counter

•Closely related to a condensation particle counter (CPC)

Page 8: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

Cascade Impactor

Page 9: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

Optical Particle Counter

• Similar to photometer, but particles are isolated• May require dilution

• 0.065 – 20 µm• Practically 0.1 – 5 µm

• Some devices just count

Page 10: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1
Page 11: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

General Discussion of Accuracy

• For what size aerosol?• For what concentration of aerosol?

• Even gravimetric

• For instruments that size• Not counting particle vs. putting particle in wrong

bin

• Manufacturer’s accuracy is not often useful• Must calculate your own based on knowledge of

instrument

Page 12: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1
Page 13: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

Aerodynamic Particle Sizer

• One of many time-of-flight instruments• Two laser beams separated by known distance• Particle is accelerated between beams• Time between beams being broken is

calibrated to test aerosol• 0.5 - 20 um

Page 14: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

APS

• Small particles move at the air velocity• Large particles lag air velocity• Problems

• Small particles not-Stokesian• Bigger density sized as larger particle• Shape also influences drag• Multiple particles in sizing chamber (same as other devices)

Page 15: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

APS air and particle flow diagram

15

Page 16: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

1616

Page 17: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

Particle Mobility Analyzer

• Particle is subjected to careful (difusive) electric charging• Charge on particle is proportional to diameter

• Electric mobility is known

• Particles are sorted by charge• Particles are counted by other technique (mostly the

condensation method)• 0.001 – 1 µm

Page 18: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

The SMPS

Consists of

1. Electrostatic

classifier (EC)

2. Differential mobility analyzer (DMA)

3. Condensation particle counter (CPC)

Page 19: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

SMPS Best for 2.5nm - 0.5m

• Can’t precisely classify larger particles b/c• Fraction of +1 and +2 charged particles begin to

converge• Changing voltages begins to cause equal fractions of

particles of the same size to fall in different bins

• Smaller particles• Fraction of charged particles gets close to 0, so

different voltages can’t control mobility

Page 20: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

Control methods/devices

• No device works (well) for all particle sizes

(a) (b)Efficiency as a function of particle diameter as measured with (a) Optical particle counter and (b) Aerodynamic particle sizer

Page 21: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

Summary

• Wide variety of instruments available for particle measurement

• What size of aerosol are you interested in?• Do you need sizing or is counting sufficient?• Do you need real-time data?• What type of aerosol are you trying to

measure?• How much accuracy do you need?• How much money do you have?

Page 22: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

22

Future Measurement Exercise

• Get manual and record data from:• TSI Aerotrack optical handheld particle counter

(4)• P-Trak (2)• DustTrak• SidePak

• Colocate all instruments in a room and see concentrations that result from different sources

• Main purpose is to understand all instruments 22

Page 23: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

Other Particle Measurement Issues

• Sampling line losses• Sampling particles in moving air stream• Particle composition• Bioaerosol sampling

Page 24: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

24

Sampling Line Losses

• Extensive literature on subject• Generally an issue for large (>1 μm) and small (<

0.05 μm) particles

• What are mechanisms that cause loss and how do we minimize them?

• Calculating line loss• Values from literature, software, or use equivalent

lines• Best approach is measurement

24

Page 25: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

25

Isokinetic Sampling

• http://www.knowledgepublications.com/hydrogen/images/Hydrogen_Gen_Gas_Gas_Stream_Lines.gifΩ√

25

Page 26: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

26

Particle Composition

• Collect sample of particles on filter• Analyze as you would for liquid or solid

compounds• Challenges?

• SMPS w/ mass spec.• Very expensive and response time issues

26

Page 27: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

27

Bioaerosol Sampling

• Many issues• Fungi, bacteria, other stuff, metabolic byproducts• Quantitative or presence/absence• Culturable, viable, DNA-based• Inhibitors

27

Page 28: 1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1

Field Measurements (Friday 2:20 p.m.)

• Address • 5404 Odessa Lane, 78731

• Type of measurement • Residential building – characterization

• Envelope air tightness

• Duct testing

• HVAC testing

• Air quality T, RH, PM, CO, O3,…

• …..

• Teams• ….

28