1 Spec-Data ® is a registered trademark of ConstructConnect. The ten-part Spec-Data format conforms to the editorial style of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2017 ConstructConnect. All Rights Reserved. METAL WALL PANELS 07 42 13 Unience USA, Inc. 1. Product Name Alfrex (Fire-rated MCM) 2. Manufacturer Unience USA, Inc., an Alfrex fr provider 2115 Linwood Avenue, Suite 500 Fort Lee, New Jersey 07024 Phone: (201) 676-2467 Fax: (201) 944-3660 Email: [email protected] Web: www.alfrexusa.com 3. Product Description Alfrex fr is a fire-rated, non-toxic metal composite material (MCM) applicable to both interior and exterior construction projects. Recognized globally for superior smoothness and performance, Alfrex fr is developed in world-class facilities using in-house technology and PVDF (polyvinylidene fluoride ) industrial finishes with PPG coating. Countless buildings around the world are now testament to the results achievable with the Alfrex fr product. Basic Use Lightweight and durable, Alfrex fr is produced in a variety of colors and finishes, making it ideal for a range of interior and exterior wall cladding. It is suitable for high-traffic non- residential and residential new construction and renovation projects. Uses include, but are not limited to: Educational institutions Offices Warehouses Infrastructure Residential Signage Composition, Materials Alfrex fr MCM panels are 4 or 6 mm thick with a fire-rated mineral filled core sandwiched between metal skins. See Table 1 for additional detail. Sizes Width: 40.2", 49.2", 62" Length (maximum): 18' See Table 1 Colors, Finishes Alfrex fr panels are available in a selection of colors and finishes. Custom colors are also available; contact Unience USA, Inc. for details. Benefits Lightweight Durable Non-permeable Excellent flame retardance Excellent physical properties and processability Available in a wide range of colors and finishes Easily formed for a range of fabrication and cladding projects 4. Technical Data Applicable Standards American Architectural Manufacturers Association (AAMA) AAMA 2605 Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels

Upload: vukhue

Post on 22-Apr-2018

221 views

Category:

Documents


4 download

TRANSCRIPT

1

Spec-Data® is a registered trademark of ConstructConnect. The ten-part Spec-Data format conforms to the editorial style of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2017 ConstructConnect. All Rights Reserved.

METAL WALL PANELS 07 42 13

Unience USA, Inc.

1. Product Name●  Alfrex (Fire-rated MCM)

2. ManufacturerUnience USA, Inc., an Alfrex fr provider 2115 Linwood Avenue, Suite 500Fort Lee, New Jersey 07024Phone: (201) 676-2467Fax: (201) 944-3660Email: [email protected]: www.alfrexusa.com

3. Product DescriptionAlfrex fr is a fire-rated, non-toxic metal composite material (MCM) applicable to both interior and exterior construction projects. Recognized globally for superior smoothness and performance, Alfrex fr is developed in world-class facilities using in-house technology and PVDF (polyvinylidene fluoride ) industrial finishes with PPG coating. Countless buildings around the world are now testament to the results achievable with the Alfrex fr product.

Basic UseLightweight and durable, Alfrex fr is produced in a variety of colors and finishes, making it ideal for a range of interior and exterior wall cladding. It is suitable for high-traffic non-residential and residential new construction and renovation projects. Uses include, but are not limited to:

● Educational institutions● Offices ● Warehouses● Infrastructure● Residential● Signage

Composition, MaterialsAlfrex fr MCM panels are 4 or 6 mm thick with a fire-rated mineral filled core sandwiched between metal skins. See Table 1 for additional detail.

Sizes● Width: 40.2", 49.2", 62" ● Length (maximum): 18' ● See Table 1

Colors, FinishesAlfrex fr panels are available in a selection of colors and finishes. Custom colors are also available; contact Unience USA, Inc. for details.

Benefits● Lightweight● Durable ● Non-permeable● Excellent flame retardance● Excellent physical properties and processability● Available in a wide range of colors and finishes●  Easily formed for a range of fabrication and cladding

projects

4. Technical Data

Applicable StandardsAmerican Architectural Manufacturers Associ ation (AAMA) ●  AAMA 2605 Voluntary Specification, Performance

Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels

2

Spec-Data® is a registered trademark of ConstructConnect. The ten-part Spec-Data format conforms to the editorial style of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2017 ConstructConnect. All Rights Reserved.

METAL WALL PANELS 07 42 13

Unience USA, Inc.

ASTM International (ASTM)●  ASTM C393 Standard Test Method for Flexural Properties of

Sandwich Constructions●  ASTM C1087 Standard Test Method for Determining

Compatibility of Liquid-Applied Sealants with Accessories Used in Structural Glazing Systems

●  ASTM D1781 Standard Test Method for Climbing Drum Peel for Adhesives

●  ASTM D1929 Standard Test Method for Determining Ignition Temperature of Plastics

●  ASTM E72 Standard Test Methods of Conducting Strength Tests of Panels for Building Construction

●  ASTM E8 Standard Test Methods for Tension Testing of Metallic Materials

●  ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

●  ASTM E119 Standard Test Methods for Fire Tests of Building Construction and Materials

●  ASTM E330 Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference

●  ASTM E331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference

● ASTM E413 Classification for Rating Sound Insulation

Standards Council of Canada/Underwriters Laboratories of Canada (CAN/ULC) ●  CAN/ULC S102 Standard Method of Test for Surface

Burning Characteristics of building Materials and Assemblies

●  CAN/ULC S134 Standard Method of Fire Test of Exterior Wall Assemblies

European National Standard (EN) ●  EN 13501-1 Fire Classification of Construction Products and

Building Elements-Part 1: Classification Using Data from Reaction to Fire Tests

International Organization for Standardization (ISO)●  ISO 9001 Quality Management Systems● ISO 14001 Environmental Management Systems

National Fire Protection Association (NFPA)●  NFPA 285 Standard Fire Test Method for Evaluation of Fire

Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components

Technical PropertiesSee Table 2.

Fire PerformanceAlfrex fr has tested to the following fire performance standards. Contact the manufacturer for test details.● ASTM D1781 ● ASTM D1929● ASTM E84 ● ASTM E119● CAN/ULC S102● CAN/ULC S134 ● EN 13501-1 ● NFPA 285

Sound PerformanceAlfrex fr has tested to the following sound performance standards Contact the manufacturer for test details.● ASTM E413

Table 1 – Composition, Size

Property Alfrex fr 0.157" (4 mm)

Alfrex fr 0.236" (6 mm)

Aluminum Skin 3003 H16 3003 H16

Skin Thickness 0.02" * (0.5 mm)

0.02" * (0.5 mm)

Core Material Fire rated, mineral filled

Fire rated, mineral filled

Weight 1.43 lb/sq ft 2.02 lb/sq ft

* Skin thickness lower than 0.5 mm are also available upon request. Custom sizes are available. Contact the manufacturer for availability.

3

Spec-Data® is a registered trademark of ConstructConnect. The ten-part Spec-Data format conforms to the editorial style of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2017 ConstructConnect. All Rights Reserved.

METAL WALL PANELS 07 42 13

Unience USA, Inc.

5. InstallationPreparatory WorkField MeasurementsVerify actual dimensions by field measurement before fabrication. Indicate all recorded measurements on shop drawings.Coordinate field measurements and fabrication schedule with construction progress. Submit drawings showing layout, profiles and product components, including anchorage, accessories, finish colors and textures. Include details showing thickness and dimensions of various system parts, fastening and anchoring methods, locations of joints and gaskets, and location and configuration of joints necessary to accommodate thermal movement. Submit selection and verification samples for finishes, colors and textures.

Delivery and StorageDeliver product in manufacturer's original, unopened, undamaged containers with identification labels intact. Panels are protected by heavy removable film during production and packaged for protection during transportation. Store materials protected from exposure to harmful environmental conditions, frost-free and at temperature and humidity levels recommended by the manufacturer. Exercise care in unloading, storing and moving to prevent bending, warping or surface damage.

Remove any damaged or deteriorated material from the job site.

MethodsShop fabricate as indicated on the drawings. Follow manufacturer's detailed installation instruction procedures. Complete instructions are available from Unience USA or online: http://alfrexusa.com/bbs/content.php?co_id=eng_installation.

InstallationInstall panels plumb, level and true, in compliance with fabricator’s recommendations.Anchor panels securely in place, in accordance with fabricator’s approved shop drawings.Comply with fabricator’s instructions for installation of concealed fasteners and with provisions of Section 07 90 00 for installation of joint sealers.

PrecautionsColor variation may occur between panels due to varying coil batches. All panels for the same project must originate from the same batch. To avoid possible reflection differences, it is imperative to install the panels in the same direction marked on the protective film. Installation Tolerances: Maximum deviation from horizontal and vertical alignment of installed panels is 0.25 inch (6.4 mm) in 20 feet (6.1 m), non-cumulative.

Table 2 – Technical Properties

Alfrex fr

Property 0.157" (4 mm) 0.236" (6 mm)

Yield Strength, ASTM E8 6962 psi 5366 psi

Tensile Strength, ASTM E8 7252 psi 5511 psi

Elongation, ASTM E8 5% 4.4%

Flexural Elasticity, ASTM C393 5221 x 103 psi 5772 x 103 psi

Specific Gravity (Product) 1.76 1.65

Specific Gravity (Core) 1.43 1.43

4

Spec-Data® is a registered trademark of ConstructConnect. The ten-part Spec-Data format conforms to the editorial style of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2017 ConstructConnect. All Rights Reserved.

METAL WALL PANELS 07 42 13

Unience USA, Inc.

Weather/Ambient ConsiderationsConsult the manufacturer for restrictions and requirements.

Building CodesInstallation must comply with requirements of all applicable local, state and federal code jurisdictions.

6. Availability and CostAlfrex fr is available worldwide. Contact Unience USA for pricing information and availability in specific areas.

7. WarrantyContact the manufacturer directly for information on panel and finish warranties.

8. MaintenanceProperly installed panels require no special maintenance. Inspect periodically for sealant integrity.

9. Technical ServicesUnience USA has fully trained design and installation professionals who can help with service and technical support. Technical assistance, including product literature, test results, project lists, assistance in preparing project specifications and arrangements for application supervision is available. Contact Unience USA or visit www.alfrexusa.com.

10. Filing Systems● CMD Group● Manu-Spec®● Master Spec®●  Additional product information is available from the

manufacturer upon request