100 years process-instrumentation 1911 – 2011€¦ · 100 years process-instrumentation 1911 –...
TRANSCRIPT
![Page 1: 100 YEARS Process-Instrumentation 1911 – 2011€¦ · 100 YEARS Process-Instrumentation 1911 – 2011 LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:16 Uhr Seite 1. Products](https://reader034.vdocuments.net/reader034/viewer/2022042309/5ed721e3c30795314c174191/html5/thumbnails/1.jpg)
Product Range
Heinrichs Messtechnik GmbHmadeinGermany
100 YEARS Process-Instrumentation1911 – 2011
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:16 Uhr Seite 1
![Page 2: 100 YEARS Process-Instrumentation 1911 – 2011€¦ · 100 YEARS Process-Instrumentation 1911 – 2011 LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:16 Uhr Seite 1. Products](https://reader034.vdocuments.net/reader034/viewer/2022042309/5ed721e3c30795314c174191/html5/thumbnails/2.jpg)
Products for thechemical industry andplant engineering
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:17 Uhr Seite 2
![Page 3: 100 YEARS Process-Instrumentation 1911 – 2011€¦ · 100 YEARS Process-Instrumentation 1911 – 2011 LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:16 Uhr Seite 1. Products](https://reader034.vdocuments.net/reader034/viewer/2022042309/5ed721e3c30795314c174191/html5/thumbnails/3.jpg)
Heinrichs Messtechnik can look backto a company tradition of 100 years.
The history of the company beganwith the construction of Variable AreaFlow Meters.
As soon as electronics conqueredmeasuring technology, the productportfolio could be extended byMagnetic-Inductive Flow Meters.
As one of the first European compa-nies, Heinrichs designed a Mass FlowMeter working with the Coriolisprinciple, 25 years ago.
The adaptation of microprocessortechnologies by the end of thenineties lead to modern communica-tion technologies as e. g. HART® andProfibus.
Following main industries are served:Chemical / PetrochemicalOil and gasEnergy and EngineeringHeinrichs offers competence, flexibilityand tailor-made solutions as e. g.special materials, high temperaturedesigns, high pressure designs, heatjacketing
Your measuring problem is ourchallenge
CompanyProfile
100 YEARS Process-Instrumentation1911 – 2011
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:17 Uhr Seite 3
![Page 4: 100 YEARS Process-Instrumentation 1911 – 2011€¦ · 100 YEARS Process-Instrumentation 1911 – 2011 LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:16 Uhr Seite 1. Products](https://reader034.vdocuments.net/reader034/viewer/2022042309/5ed721e3c30795314c174191/html5/thumbnails/4.jpg)
Advantages
• service and maintenance freeconstruction
• no filter needed• non sensitive against vibrations• non sensitive against tension of
the piping
Ranges: liquids 0...40 000 kg/h, gases 0...30 000 m³N/hAccuracy:liquids: ±0,1% of actualgases: ±0,5% of actualMax. pressure: 40 bar (special versions up to 900 bar)Max. temperature: -90...+300°CProcess connections: DIN, ANSI, JIS, NPT or special DN 10...DN 100
Coriolis Mass FlowmeterMeasurement of Mass-, volume, density and temperature
Model: TM (Universal Line)
High Accuracy, special versions available,media heating optional
Ranges: liquid 0...120 000 kg/h, gases, 0...92 000 m³N/h LuftAccurancy: liquids ±0,1% of actual, gases ±0,5% of actualProcess connection: Flange DN20 -100, DIN (ANSI)Max. temperature: -40...+260°CMax. pressure: 40 bar (600 lbs)
Coriolis Mass Flowmeter
Compact mounting length, compatible with PD meters
Model: TMR (Compact Line)Replacement for e.g. Oveal Gear Meters, Piston Meters
Coriolis Mass Flowmeter
Model: TMU (Classic Line)High Measuring Span
Ranges: liquids 0...60 000 kg/h, gases 0,02...46 000 m³N/hAccuracyliquids: ±0,15% of actualgases: ±0,5% of actualMax. pressure 40 bar, Max. temperature -40...+180°CProcess connections: DIN, ANSI, DN 10...DN 80
Housing: cast iron
Coriolis Mass Flowmeter
Model: TME (Economy Line)
Ranges: liquids 0...2 200 000 kg/h, gases 0,05...1 700 000 m³N/hAccuracyliquids: ±0,1% of actualgases: ±0,5% of actualMax. temperature: -40...+260 °C;Max. pressure: 40 bar /300 lbsProcess connection: DIN, ANSI, JIS, NPT DN 10...DN 400
Overview
HART® registered Trademark of HART Communication Foundation, Austin, USAProfibus® registered Trademark of PROFIBUS User Organisation e. V., Karlsruhe
Fieldbus registered Trademark of Fieldbus Foundation, Austin, USA
Up to 900 barUp to 2200000 kg/h
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:17 Uhr Seite 4
Advantages
• service and maintenance freeconstruction
• no filter needed• non sensitive against vibrations• non sensitive against tension of
the piping
Ranges: liquids 0...40 000 kg/h, gases 0...30 000 m³N/hAccuracy:liquids: ±0,1% of actualgases: ±0,5% of actualMax. pressure: 40 bar (special versions up to 900 bar)Max. temperature: -90...+300°CProcess connections: DIN, ANSI, JIS, NPT or special DN 10...DN 100
Hastelloy C22, B2, Tantal, Nickel, Monel, Zirkonium,or special
Coriolis Mass FlowmeterMeasurement of Mass-, volume, density and temperature
Model: TM (Universal Line)
High Accuracy, special versions available,media heating optional
Ranges: liquid 0...120 000 kg/h, gases, 0...92 000 m³N/h LuftAccurancy: liquids ±0,1% of actual, gases ±0,5% of actualProcess connection: Flange DN20 -100, DIN (ANSI)Max. temperature: -40...+260°CMax. pressure: 40 bar (600 lbs)
Coriolis Mass Flowmeter
Compact mounting length, compatible with PD meters
Model: TMR (Compact Line)Replacement for e.g. Oveal Gear Meters, Piston Meters
Coriolis Mass Flowmeter
Model: TMU (Classic Line)High Measuring Span
Ranges: liquids 0...60 000 kg/h, gases 0,02...46 000 m³N/hAccuracyliquids: ±0,15% of actualgases: ±0,5% of actualMax. pressure 40 bar, Max. temperature -40...+180°CProcess connections: DIN, ANSI, DN 10...DN 80Material: st.st., Hastelloy C22, B2, Tantal, or specialHousing: cast iron
Coriolis Mass Flowmeter
Model: TME (Economy Line)
Ranges: liquids 0...2 200 000 kg/h, gases 0,05...1 700 000 m³N/hAccuracyliquids: ±0,1% of actualgases: ±0,5% of actualMax. temperature: -40...+260 °C;Max. pressure: 40 bar /300 lbsProcess connection: DIN, ANSI, JIS, NPT DN 10...DN 400Material: st.st., Hastelloy C22, B2, Tantal, or special
Overview
HART® registered Trademark of HART Communication Foundation, Austin, USAProfibus® registered Trademark of PROFIBUS User Organisation e. V., Karlsruhe
Fieldbus registered Trademark of Fieldbus Foundation, Austin, USA
Up to 900 barUp to 2200000 kg/h
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:17 Uhr Seite 4
HART® registered Trademark of HART Communication Foundation, Austin, USAProfibus® regitered Trademark of PROFIBUS User Organisation e. V., Karlsruhe
Fieldbus registered Trademark of Fieldbus Foundation, Austin, USA
Subject to modification
Material: st.st., Hastelloy C22, C4, Tantal, Nickel,other on request Material: st.st., Hastelloy C22, C4, Tantal
Measurement of Density, Temperature, Volume flow
Measurement of Density, Temperature, Volume flow
![Page 5: 100 YEARS Process-Instrumentation 1911 – 2011€¦ · 100 YEARS Process-Instrumentation 1911 – 2011 LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:16 Uhr Seite 1. Products](https://reader034.vdocuments.net/reader034/viewer/2022042309/5ed721e3c30795314c174191/html5/thumbnails/5.jpg)
Measuring range: 3-8 …3057-280000 Nm3/hAccuracy: ±0,7/ of actual (liquids) ± 1% of actual (gases)Max. temperature: 400 °CMax. pressure: 100 barProcess connection: DN 15-DN 200 / ½ ANSI up to 8" ANSIMaterial: stainless steel ATEX, IEC EX
Vortex Flowmeter INLINE-Version
Model DVH
Overview
Measuring range: 0,4...60.000 kg/h, 0,02...46.000 m³/Nh airAccuracy: Liquid ±0,15% of actual ± ZP-StabilityGases: ±0,5% of actual ± ZP-StabilityMax. temperature: 180 °C; Max pressure: 40 bar / 300 lbsConnection: Flange DN10-80 /ANSI 1⁄2"-3"Material: stainless steel 1.4571 (316 Ti) oder 1.4404 (316 L)Case: Cast iron
Mass Flowmeter-Coriolis
Stainless steel
Model: TME/UMC-4
Measuring range: up to 600 kg/h GasProcess pressure: up to 1000 bar
Coriolis Mass Flowmeter
High Pressure Version
For High Pressure – Filling Applications (H2)
Vortex Flowmeter Insertion-Version
Model DVE
Measuring range: 89-1463 …26915-2467000 Nm3/hAccuracy: ±1,2 %/ of actual (liquids) ± 1,5% of actual (gases)Max. temperature: 400 °CMax. pressure: 100 barProcess connection: for pipe sizes DN 80 up to DN 600 / 24"Material: stainless steel ATEX, IEC EX
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:18 Uhr Seite 7
Measuring range: 3-8 …3057-280000 Nm3/hAccuracy: ±0,7/ of actual (liquids) ± 1% of actual (gases)Max. temperature: 400 °CMax. pressure: 100 barProcess connection: DN 15-DN 200 / ½ ANSI up to 8" ANSIMaterial: stainless steel ATEX, IEC EX
Vortex Flowmeter INLINE-Version
Model DVH
Overview
Measuring range: 0,4...60.000 kg/h, 0,02...46.000 m³/Nh airAccuracy: Liquid ±0,15% of actual ± ZP-StabilityGases: ±0,5% of actual ± ZP-StabilityMax. temperature: 180 °C; Max pressure: 40 bar / 300 lbsConnection: Flange DN10-80 /ANSI 1⁄2"-3"Material: stainless steel 1.4571 (316 Ti) oder 1.4404 (316 L)Case: Cast iron
Mass Flowmeter-Coriolis
Stainless steel
Model: TME/UMC-4
Measuring range: up to 600 kg/h GasProcess pressure: up to 1000 bar
Coriolis Mass Flowmeter
High Pressure Version
For High Pressure – Filling Applications (H2)
Vortex Flowmeter Insertion-Version
Model DVE
Measuring range: 89-1463 …26915-2467000 Nm3/hAccuracy: ±1,2 %/ of actual (liquids) ± 1,5% of actual (gases)Max. temperature: 400 °CMax. pressure: 100 barProcess connection: for pipe sizes DN 80 up to DN 600 / 24"Material: stainless steel ATEX, IEC EX
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:18 Uhr Seite 7
Subject to modification
![Page 6: 100 YEARS Process-Instrumentation 1911 – 2011€¦ · 100 YEARS Process-Instrumentation 1911 – 2011 LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:16 Uhr Seite 1. Products](https://reader034.vdocuments.net/reader034/viewer/2022042309/5ed721e3c30795314c174191/html5/thumbnails/6.jpg)
Ranges: 0-10 m/s liquidAccuracy: ±1,5% of actual flow +0,5% of FSMaterial: st.st., 1.4571 / 316TI, PFA, PTFE, PVDFMax. temperature: -40...+140 °C;Max. pressure: 40 barProcess connction: weld-on connection for pipes DN100...2000Output signal: Analoge- or pulse output,Transmitter: Analog-, pulse output, digital indication, HART®,ATEX
Magnetic Inductive Flowmeter - Immersion Type
Model: PIT
Overview
Ranges: 0,4...2500 m³/h liquidAccuracy: ±0,3% of actual flow ±0,01% of FSMin. conductivity: ≥5 µS/cm (liquids in general)
≥20 µS/cm (demin. Water)pmax: PN40; tmax: -20...+150 °CProcess connection: flange DN15...600, ANSI ¾“...24“Lining materials: hard rubber, soft rubber, PTFE, Wagunit, RILSANOutput signals: Analog, HART®, pulse or status output
Magnetic Inductive Flowmeter
for conductive liquids
Model: EP / UMF 2
Ranges: 0,05-1,0 L/min...40-800 L/minAccuracy: ±2,0% v. MEpmax: 10 bar; tmax: 80 °CProcess connections: G ½...G 2¾ male, hose connection, glueconnection, weld endsMaterial: PPS, st.st., PVDF, HastelloyOutput signals: Analog, status / switching output
Magnetic Inductive Flowmeter - Compact Version -
Pulse - switch output, analoge output, digital indication, coun-ter, batch controller
Model: MIK
Flap Flowmeter for liquids
Model: TSK
Range: 1,5-10...200-1300 m³/h liquidAccuracy: ±2,5% FSMax. temperature: -40...+ 200°CMax. pressure: 40 bar, from DN100 on 16 bar, from DN 200 on 10 barhigher pressure ratings possibleProcess connection: wafer DN 50...500 /ANSI 2"...20"Material: carbon steel, st.st., PP, PTFE, HastelloyOptions: limit switches, Analog output, HART®,Profibus PA®, Fieldbus, ATEX
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:17 Uhr Seite 5
Ranges: 0-10 m/s liquidAccuracy: ±1,5% of actual flow +0,5% of FSMaterial: st.st., 1.4571 / 316TI, PFA, PTFE, PVDFMax. temperature: -40...+140 °C;Max. pressure: 40 barProcess connction: weld-on connection for pipes DN100...2000Output signal: Analoge- or pulse output,Transmitter: Analog-, pulse output, digital indication, HART®,ATEX
Magnetic Inductive Flowmeter - Immersion Type
Model: PIT
Overview
Ranges: 0,4...2500 m³/h liquidAccuracy: ±0,3% of actual flow ±0,01% of FSMin. conductivity: ≥5 µS/cm (liquids in general)
≥20 µS/cm (demin. Water)pmax: PN40; tmax: -20...+150 °CProcess connection: flange DN15...600, ANSI ¾“...24“Lining materials: hard rubber, soft rubber, PTFE, Wagunit, RILSANOutput signals: Analog, HART®, pulse or status output
Magnetic Inductive Flowmeter
for conductive liquids
Model: EP / UMF 2
Ranges: 0,05-1,0 L/min...40-800 L/minAccuracy: ±2,0% v. MEpmax: 10 bar; tmax: 80 °CProcess connections: G ½...G 2¾ male, hose connection, glueconnection, weld endsMaterial: PPS, st.st., PVDF, HastelloyOutput signals: Analog, status / switching output
Magnetic Inductive Flowmeter - Compact Version -
Pulse - switch output, analoge output, digital indication, coun-ter, batch controller
Model: MIK
Flap Flowmeter for liquids
Model: TSK
Range: 1,5-10...200-1300 m³/h liquidAccuracy: ±2,5% FSMax. temperature: -40...+ 200°CMax. pressure: 40 bar, from DN100 on 16 bar, from DN 200 on 10 barhigher pressure ratings possibleProcess connection: wafer DN 50...500 /ANSI 2"...20"Material: carbon steel, st.st., PP, PTFE, HastelloyOptions: limit switches, Analog output, HART®,Profibus PA®, Fieldbus, ATEX
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:17 Uhr Seite 5
Ranges: 0-10 m/s liquidAccuracy: ±1,5% of actual flow +0,5% of FSMaterial: st.st., 1.4571 / 316TI, PFA, PTFE, PVDFMax. temperature: -40...+140 °C;Max. pressure: 40 barProcess connction: weld-on connection for pipes DN100...2000Output signal: Analoge- or pulse output,Transmitter: Analog-, pulse output, digital indication, HART®,ATEX
Magnetic Inductive Flowmeter - Immersion Type
Model: PIT
Overview
Ranges: 0,4...2500 m³/h liquidAccuracy: ±0,3% of actual flow ±0,01% of FSMin. conductivity: ≥5 µS/cm (liquids in general)
≥20 µS/cm (demin. Water)pmax: PN40; tmax: -20...+150 °CProcess connection: flange DN15...600, ANSI ¾“...24“Lining materials: hard rubber, soft rubber, PTFE, Wagunit, RILSANOutput signals: Analog, HART®, pulse or status output
Magnetic Inductive Flowmeter
for conductive liquids
Model: EP / UMF 2
Ranges: 0,05-1,0 L/min...40-800 L/minAccuracy: ±2,0% v. MEpmax: 10 bar; tmax: 80 °CProcess connections: G ½...G 2¾ male, hose connection, glueconnection, weld endsMaterial: PPS, st.st., PVDF, HastelloyOutput signals: Analog, status / switching output
Magnetic Inductive Flowmeter - Compact Version -
Pulse - switch output, analoge output, digital indication, coun-ter, batch controller
Model: MIK
Flap Flowmeter for liquids
Model: TSK
Range: 1,5-10...200-1300 m³/h liquidAccuracy: ±2,5% FSMax. temperature: -40...+ 200°CMax. pressure: 40 bar, from DN100 on 16 bar, from DN 200 on 10 barhigher pressure ratings possibleProcess connection: wafer DN 50...500 /ANSI 2"...20"Material: carbon steel, st.st., PP, PTFE, HastelloyOptions: limit switches, Analog output, HART®,Profibus PA®, Fieldbus, ATEX
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:17 Uhr Seite 5
Subject to modifi cation
![Page 7: 100 YEARS Process-Instrumentation 1911 – 2011€¦ · 100 YEARS Process-Instrumentation 1911 – 2011 LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:16 Uhr Seite 1. Products](https://reader034.vdocuments.net/reader034/viewer/2022042309/5ed721e3c30795314c174191/html5/thumbnails/7.jpg)
Variable Area Flowmeter
Model: BGN
Ranges: 0,5-5...13 000-130 000 L/h liquid0,015-0,15...240-2400 m³N/h airAccuracy: ±1,6%FS (±2% for gases)Material: st.st., PTFE-lining, Hastelloy (other material possible)Max. temperature: -40...+350°C (other on request)Max. pressure: 40 bar (up to 550 bar on request)Process connection: flange DN15-150 / ANSI ¾"...6", femalethread, male thread, hygienic, TriClamp, Ermeto, Swagelokand many other on requestOptions: Analog output, limit switches, counter, HART®,Profibus PA®, Fieldbus
Ranges: 0,1-1,0...20-200 L/h water3-30...600-6000 LN/h airAccuracy: ±3% FSMaterial: st.st., glassMax. temperature: -40...+130 °C (-25...+100 °C with contact)Max. pressure: 16 barProcess connection: ¼ NPT, Flange DN15, 25, ANSI ¾", 1"Swagelok, ErmetoOptions: limit switches, inlet-/outlet differential pressure regulator
Installation lengths: 90 mm / 125 mm / 175 mm / 320 mmRanges: 0,020,25...10-200 L/h water2-20...150-3000 LN/h airAccuracy: ±1%; 2% oder 3% FS (depending on tube length)Material: st.st., glassMax. temperature: 0...+100°C, (0...+70°C with contact)Max. pressure: 16 barProcess connection: G ¼, G ½, ¼ NPT, Swagelok, ErmetoOptions: limit switches, inlet-/outlet differential pressure regulator
Low Volume Variable Area Flowmeter
Model: K09/K12/K17/K32
Overview
Variable Area Flowmeter – horizontal mounting –
Model: BGF
Ranges: 6-160...4 000-40 000 L/h liquid0,5-4,6...280-2800 m³N/h air
Accuracy: ±2,0% FSMaterial: st.st. PTFE-liningMax. temperature: -40...+350°C (other on request)Max. pressure: 40 bar (up to 500 bar on request)Process connection: flange DN15-100 / ANSI ¾"-4",femalethread, male thread, hygienic, TriClamp, Ermeto, Swagelokand many other on requestOptions: Analog output, limit switches, counter,HART®, Profibus PA®
Up to 550 bar
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:18 Uhr Seite 6
Variable Area Flowmeter
Model: BGN
Ranges: 0,5-5...13 000-130 000 L/h liquid0,015-0,15...240-2400 m³N/h airAccuracy: ±1,6%FS (±2% for gases)Material: st.st., PTFE-lining, Hastelloy (other material possible)Max. temperature: -40...+350°C (other on request)Max. pressure: 40 bar (up to 550 bar on request)Process connection: flange DN15-150 / ANSI ¾"...6", femalethread, male thread, hygienic, TriClamp, Ermeto, Swagelokand many other on requestOptions: Analog output, limit switches, counter, HART®,Profibus PA®, Fieldbus, ATEX
Ranges: 0,1-1,0...20-200 L/h water3-30...600-6000 LN/h airAccuracy: ±3% FSMaterial: st.st., glassMax. temperature: -40...+130 °C (-25...+100 °C with contact)Max. pressure: 16 barProcess connection: ¼ NPT, Flange DN15, 25, ANSI ¾", 1"Swagelok, ErmetoOptions: limit switches, inlet-/outlet differential pressure regulator
Installation lengths: 90 mm / 125 mm / 175 mm / 320 mmRanges: 0,020,25...10-200 L/h water2-20...150-3000 LN/h airAccuracy: ±1%; 2% oder 3% FS (depending on tube length)Material: st.st., glassMax. temperature: 0...+100°C, (0...+70°C with contact)Max. pressure: 16 barProcess connection: G ¼, G ½, ¼ NPT, Swagelok, ErmetoOptions: limit switches, inlet-/outlet differential pressure regulator ATEX
Low Volume Variable Area Flowmeter
Model: K09/K12/K17/K32
Overview
Variable Area Flowmeter – horizontal mounting –
Model: BGF
Ranges: 6-160...4 000-40 000 L/h liquid0,5-4,6...280-2800 m³N/h air
Accuracy: ±2,0% FSMaterial: st.st. PTFE-liningMax. temperature: -40...+350°C (other on request)Max. pressure: 40 bar (up to 500 bar on request)Process connection: flange DN15-100 / ANSI ¾"-4",femalethread, male thread, hygienic, TriClamp, Ermeto, Swagelokand many other on requestOptions: Analog output, limit switches, counter,HART®, Profibus PA®, Fieldbus, ATEX
Up to 550 bar
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:18 Uhr Seite 6
Variable Area Flowmeter
Model: BGN
Ranges: 0,5-5...13 000-130 000 L/h liquid0,015-0,15...240-2400 m³N/h airAccuracy: ±1,6%FS (±2% for gases)Material: st.st., PTFE-lining, Hastelloy (other material possible)Max. temperature: -40...+350°C (other on request)Max. pressure: 40 bar (up to 550 bar on request)Process connection: flange DN15-150 / ANSI ¾"...6", femalethread, male thread, hygienic, TriClamp, Ermeto, Swagelokand many other on requestOptions: Analog output, limit switches, counter, HART®,Profibus PA®, Fieldbus, ATEX
Ranges: 0,1-1,0...20-200 L/h water3-30...600-6000 LN/h airAccuracy: ±3% FSMaterial: st.st., glassMax. temperature: -40...+130 °C (-25...+100 °C with contact)Max. pressure: 16 barProcess connection: ¼ NPT, Flange DN15, 25, ANSI ¾", 1"Swagelok, ErmetoOptions: limit switches, inlet-/outlet differential pressure regulator
Installation lengths: 90 mm / 125 mm / 175 mm / 320 mmRanges: 0,020,25...10-200 L/h water2-20...150-3000 LN/h airAccuracy: ±1%; 2% oder 3% FS (depending on tube length)Material: st.st., glassMax. temperature: 0...+100°C, (0...+70°C with contact)Max. pressure: 16 barProcess connection: G ¼, G ½, ¼ NPT, Swagelok, ErmetoOptions: limit switches, inlet-/outlet differential pressure regulator ATEX
Low Volume Variable Area Flowmeter
Model: K09/K12/K17/K32
Overview
Variable Area Flowmeter – horizontal mounting –
Model: BGF
Ranges: 6-160...4 000-40 000 L/h liquid0,5-4,6...280-2800 m³N/h air
Accuracy: ±2,0% FSMaterial: st.st. PTFE-liningMax. temperature: -40...+350°C (other on request)Max. pressure: 40 bar (up to 500 bar on request)Process connection: flange DN15-100 / ANSI ¾"-4",femalethread, male thread, hygienic, TriClamp, Ermeto, Swagelokand many other on requestOptions: Analog output, limit switches, counter,HART®, Profibus PA®, Fieldbus, ATEX
Up to 550 bar
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:18 Uhr Seite 6
Subject to modification
Variable Area Flow MeterModel: KDS/BGK
NEW: KDS-E Analog Output
, Fieldbus¢¢
![Page 8: 100 YEARS Process-Instrumentation 1911 – 2011€¦ · 100 YEARS Process-Instrumentation 1911 – 2011 LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:16 Uhr Seite 1. Products](https://reader034.vdocuments.net/reader034/viewer/2022042309/5ed721e3c30795314c174191/html5/thumbnails/8.jpg)
Range: 6,5...65-100...10 000 L/h water150...1500-18 000...180 000 Nm3/h airAccuracy: liquid 1,6%, gases 2,5% FSMaterial: st.st., glassMax. temperature: -10...+100°CMax. pressure: 10 barProcess connection: flange DN 15- DN 50, G 1/2-G2, Hygenic,TriClamp, glue connectionOptions: limit switches
Variable Area Flowmeter with Protection Tube
Overview
Ranges: 1,5...11-8000... 60000 L/h water0,15...0,45-100...860 m³N/h air
Accuracy: class 4 acc VDIMaterial: Polysulfone, TrogamideMax. temperature: 100 °CMax. pressure: 16 barProcess connection: G½ - G 3½, glue connection, flangeOption: limit switches
Variable Area Flowmeter – Plastic Body
Inline Density Weighing System for Liquids
Model: DWF
Range: 700...1900g/LSpan: 50...600 g/LAccuracy: ±1,25-6,0 g/k (depending on span)Max. flow 2500/5000/10 000 L/hMax. temperature: -20...+150°C;Max. pressure: 16 barMaterial: st.st., Hastelloy (other on request)Process connection: flange DN25, DN50Options: Analog output, limit switches, HART®, Profibus-PA®,Fieldbus, ATEX
Suitable
for
multiphase media
Range: max. 2 x 6 m, liquids up to density range of 400-2000 g/LAccuracy: ±5 mm of actual rangeMax. temperature: -40...+ 250°CMax. pressure: 320 barProcess connection: up to DN100 / ANSI 4"Material: st.st., Hastelloy COptions: limit switches, analoge output, HART®, Profibus PA, FieldbusATEX: (Zone 0, inside vessel)
Level- and Interlayer Instrument acc.
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:18 Uhr Seite 8
Range: 6,5...65-100...10 000 L/h water150...1500-18 000...180 000 Nm3/h airAccuracy: liquid 1,6%, gases 2,5% FSMaterial: st.st., glassMax. temperature: -10...+100°CMax. pressure: 10 barProcess connection: flange DN 15- DN 50, G 1/2-G2, Hygenic,TriClamp, glue connectionOptions: limit switches
Variable Area Flowmeter with Protection Tube
V31
Overview
Ranges: 1,5...11-8000... 60000 L/h water0,15...0,45-100...860 m³N/h air
Accuracy: class 4 acc VDIMaterial: Polysulfone, TrogamideMax. temperature: 100 °CMax. pressure: 16 barProcess connection: G½ - G 3½, glue connection, flangeOption: limit switches
Variable Area Flowmeter – Plastic Body
Model: KSK/KSM
Inline Density Weighing System for Liquids
Model: DWF
Range: 700...1900g/LSpan: 50...600 g/LAccuracy: ±1,25-6,0 g/k (depending on span)Max. flow 2500/5000/10 000 L/hMax. temperature: -20...+150°C;Max. pressure: 16 barMaterial: st.st., Hastelloy (other on request)Process connection: flange DN25, DN50Options: Analog output, limit switches, HART®, Profibus-PA®,Fieldbus, ATEX
Suitablefor
multiphase media
Range: max. 2 x 6 m, liquids up to density range of 400-2000 g/LAccuracy: ±5 mm of actual rangeMax. temperature: -40...+ 250°CMax. pressure: 320 barProcess connection: up to DN100 / ANSI 4"Material: st.st., Hastelloy COptions: limit switches, analoge output, HART®, Profibus PA, FieldbusATEX: (Zone 0, inside vessel)
Level- and Interlayer Instrument acc.
the archimedian principle
Model: BA
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:18 Uhr Seite 8
Subject to modification
Glass TubeModel: V31
Plastic TubeModel: KSK/KSM
Boyancy PrincipleModel: BA
![Page 9: 100 YEARS Process-Instrumentation 1911 – 2011€¦ · 100 YEARS Process-Instrumentation 1911 – 2011 LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:16 Uhr Seite 1. Products](https://reader034.vdocuments.net/reader034/viewer/2022042309/5ed721e3c30795314c174191/html5/thumbnails/9.jpg)
Overview
Dual Magnet Float Level Switch
Model: NGS
for side mounting,Housing sea water resistantApprovals: GL, ATEXMaterial: Aluminium bronze, st.st.
Density range: ≥0,7 kg/dm³pmax: 25 bar; tmax: 250 °CProcess connection: DIN flange, BSP, NPT (special on request)
Tuning Fork Liquid Level Switch for viscous Media
Model: NWS
Capacitive Level Sensor for Liquids
Model: NMC
Accuracy: ±1 mm depending on spanMax. temperature: 130°C;Max. pressure: 50 barProcess connection: G 3/4, G1, NPT, flange, hygienic, TriClamp
Accuracy: ±2 mm, acc to spanMax. temperature: 125°C;Max. pressure: 50 barProcess connection: G1, flangeIndication: LCD, alphanumeric display
Indication range: max. 6000 mm (>6m two part version)Viscosity range: max. 200 mm2/sMin. desity: 0,4 kg/dm3pmax: 320 bar; tmax: 400 °CProcess connection: flange DN15 ...DN50, ANSI, Thread,(special on request)
Bypass Level Indicator
c/w roller or ball indication
Model: NBK-MBSK
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:18 Uhr Seite 9
Overview
Dual Magnet Float Level Switch
Model: NGS
for side mounting,Housing sea water resistantApprovals: GL, ATEXMaterial: Aluminium bronze, st.st.
Density range: ≥0,7 kg/dm³pmax: 25 bar; tmax: 250 °CProcess connection: DIN flange, BSP, NPT (special on request)
Tuning Fork Liquid Level Switch for viscous Media
Model: NWS
Capacitive Level Sensor for Liquids
Model: NMC
Accuracy: ±1 mm depending on spanMax. temperature: 130°C;Max. pressure: 50 barProcess connection: G 3/4, G1, NPT, flange, hygienic, TriClampOptions: st.st. housing, ATEX
Accuracy: ±2 mm, acc to spanMax. temperature: 125°C;Max. pressure: 50 barProcess connection: G1, flangeIndication: LCD, alphanumeric displayOptions: ATEX
Indication range: max. 6000 mm (>6m two part version)Viscosity range: max. 200 mm2/sMin. desity: 0,4 kg/dm3pmax: 320 bar; tmax: 400 °CProcess connection: flange DN15 ...DN50, ANSI, Thread,(special on request)Options: Analog output; limit switches, ATEX, GL
Bypass Level Indicator
c/w roller or ball indication
Model: NBK-MBSK
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:18 Uhr Seite 9
Subject to modification
Options: Analog output; limit switches Options: st.st. housing�
![Page 10: 100 YEARS Process-Instrumentation 1911 – 2011€¦ · 100 YEARS Process-Instrumentation 1911 – 2011 LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:16 Uhr Seite 1. Products](https://reader034.vdocuments.net/reader034/viewer/2022042309/5ed721e3c30795314c174191/html5/thumbnails/10.jpg)
10
Übersicht
Irrtum und technische Änderungen vorbehalten
Radar / Geführte Mikrowelle (TDR)Edelstahl / PTFETyp: NGM
Druck-MessumformerEdelstahl, Hastelloy-C, TantalTyp: PASHigh Quality - Low Cost
WiderstandstemperaturmessgerätEdelstahlTyp: TWL
Differenzdruck-MessumformerEdelstahl, Monel, Tantal, HastelloyTyp: PADHigh Quality - Low Cost
Ausführung: Stab-, Seil-, KoaxialvarianteAnwendung: Flüssigkeiten und Schüttgüter Messbereich: Stab max. 6 m, Seil max. 20 mpmax: 40 bar tmax:-200 ... +250 °CAnschluss: G ¾, ¾" NPT, FlanschGenauigkeit: ± 3 mmOptionen: Grenzschalter, Analogausgang, HART®
Messbereich: -1 ... +1,5 bar ... 0 ... 600 barMaterial: Edelstahl, Tantal, Hastelloy Anschluss: ¼" NPT IG, ½" NPT IG, DruckmitterTemperatur: -40 ... +120 °C (Druckmittler bis 250 °C)Genauigkeit: ± 0,075 % der kalibrierten Messspanne
Messbereich: -80 ... +600 °CSensor: 1 oder 2 Pt 100, Kl. A oder Bpmax: 250 barAnschluss: Gewinde, Flansch, EinschweißhülseAusgang: Analogausgang, Widerstand, Profi bus® PAOption: Digitalanzeige
Messbereich: +0,75 ... 15 mbar ... 4,137 ... +413,70 barMaterial: Edelstahl, Tantal, Hastelloy Anschluss: ¼" NPT, ½" NPT, DruckmitterTemperatur: -40 ... +120 °C (Druckmittler bis 250 °C)Genauigkeit: ± 0,075 % der Messspanne
PÜ_Heinrichs_Inhalt_alle.indd 10 12.07.2013 07:30:05
Overview
Differential Pressure TransmitterSt. steel, Monel, Tantalum, Hastelloy
Model: PADHigh Quality - Low Cost
Measuring range: +0,0075 ... +41370 kPaPower supply: 18-45 VDC
Connection: 1⁄4 NPT, 1⁄2 NPTAccuracy: ± 0,075% of measuring range
Pressure Transmitter
Stainless steel, Hastelloy-C, Tantalum
Model: PAS
High Quality - Low Cost
Resistance TemperatureMeasuring UnitStainless steelModel: TWL
Measuring range: -1 ... + 600 barPower supply: 11,9-45 VDCConnection: 1⁄4 NPT IG, 1⁄2 NPT IGAccuracy: ± 0,075% of actual
Measuring range: -200 ... +750 °Cpmax: 250 barConnection: Thread, flange, weld-in sleevePt 100, 4...20 mAAccuracy: Cl. A or B
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:18 Uhr Seite 10
Overview
Differential Pressure TransmitterSt. steel, Monel, Tantalum, Hastelloy
Model: PADHigh Quality - Low Cost
Measuring range: +0,0075 ... +41370 kPaPower supply: 18-45 VDC
Connection: 1⁄4 NPT, 1⁄2 NPTAccuracy: ± 0,075% of measuring range
Pressure Transmitter
Stainless steel, Hastelloy-C, Tantalum
Model: PAS
High Quality - Low Cost
Resistance TemperatureMeasuring UnitStainless steelModel: TWL
Measuring range: -1 ... + 600 barPower supply: 11,9-45 VDCConnection: 1⁄4 NPT IG, 1⁄2 NPT IGAccuracy: ± 0,075% of actual
Measuring range: -200 ... +750 °Cpmax: 250 barConnection: Thread, flange, weld-in sleevePt 100, 4...20 mAAccuracy: Cl. A or B
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:18 Uhr Seite 10
Guided Wave Radar (TDR)st.st. / PTFE
Type: NGM
Available version: rod, rope, koaxial versionApplication: liquids and bulksMeasuring range: rod max. 6 m, rope max. 20 mtmax-200 .... +250 °C, Pmax 40 barProcess connection: G ¾, ¾ NPT, FlangeLimit switch PNP, analog output 4-20 mA, HART
Subject to modifi cation 10
Übersicht
Irrtum und technische Änderungen vorbehalten
Radar / Geführte Mikrowelle (TDR)Edelstahl / PTFETyp: NGM
Druck-MessumformerEdelstahl, Hastelloy-C, TantalTyp: PASHigh Quality - Low Cost
WiderstandstemperaturmessgerätEdelstahlTyp: TWL
Differenzdruck-MessumformerEdelstahl, Monel, Tantal, HastelloyTyp: PADHigh Quality - Low Cost
Ausführung: Stab-, Seil-, KoaxialvarianteAnwendung: Flüssigkeiten und Schüttgüter Messbereich: Stab max. 6 m, Seil max. 20 mpmax: 40 bar tmax:-200 ... +250 °CAnschluss: G ¾, ¾" NPT, FlanschGenauigkeit: ± 3 mmOptionen: Grenzschalter, Analogausgang, HART®
Messbereich: -1 ... +1,5 bar ... 0 ... 600 barMaterial: Edelstahl, Tantal, Hastelloy Anschluss: ¼" NPT IG, ½" NPT IG, DruckmitterTemperatur: -40 ... +120 °C (Druckmittler bis 250 °C)Genauigkeit: ± 0,075 % der kalibrierten Messspanne
Messbereich: -80 ... +600 °CSensor: 1 oder 2 Pt 100, Kl. A oder Bpmax: 250 barAnschluss: Gewinde, Flansch, EinschweißhülseAusgang: Analogausgang, Widerstand, Profi bus® PAOption: Digitalanzeige
Messbereich: +0,75 ... 15 mbar ... 4,137 ... +413,70 barMaterial: Edelstahl, Tantal, Hastelloy Anschluss: ¼" NPT, ½" NPT, DruckmitterTemperatur: -40 ... +120 °C (Druckmittler bis 250 °C)Genauigkeit: ± 0,075 % der Messspanne
PÜ_Heinrichs_Inhalt_alle.indd 10 12.07.2013 07:30:05
Overview
Differential Pressure TransmitterSt. steel, Monel, Tantalum, Hastelloy
Model: PADHigh Quality - Low Cost
Measuring range: +0,0075 ... +41370 kPaPower supply: 18-45 VDC
Connection: 1⁄4 NPT, 1⁄2 NPTAccuracy: ± 0,075% of measuring range
Pressure Transmitter
Stainless steel, Hastelloy-C, Tantalum
Model: PAS
High Quality - Low Cost
Resistance TemperatureMeasuring UnitStainless steelModel: TWL
Measuring range: -1 ... + 600 barPower supply: 11,9-45 VDCConnection: 1⁄4 NPT IG, 1⁄2 NPT IGAccuracy: ± 0,075% of actual
Measuring range: -200 ... +750 °Cpmax: 250 barConnection: Thread, flange, weld-in sleevePt 100, 4...20 mAAccuracy: Cl. A or B
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:18 Uhr Seite 10
Overview
Differential Pressure TransmitterSt. steel, Monel, Tantalum, Hastelloy
Model: PADHigh Quality - Low Cost
Measuring range: +0,0075 ... +41370 kPaPower supply: 18-45 VDC
Connection: 1⁄4 NPT, 1⁄2 NPTAccuracy: ± 0,075% of measuring range
Pressure Transmitter
Stainless steel, Hastelloy-C, Tantalum
Model: PAS
High Quality - Low Cost
Resistance TemperatureMeasuring UnitStainless steelModel: TWL
Measuring range: -1 ... + 600 barPower supply: 11,9-45 VDCConnection: 1⁄4 NPT IG, 1⁄2 NPT IGAccuracy: ± 0,075% of actual
Measuring range: -200 ... +750 °Cpmax: 250 barConnection: Thread, flange, weld-in sleevePt 100, 4...20 mAAccuracy: Cl. A or B
Subject to modification
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:18 Uhr Seite 10
Guided Wave Radar (TDR)st.st. / PTFE
Type: NGM
Available version: rod, rope, koaxial versionApplication: liquids and bulksMeasuring range: rod max. 6 m, rope max. 20 mtmax-200 .... +250 °C, Pmax 40 barProcess connection: G ¾, ¾ NPT, FlangeLimit switch PNP, analog output 4-20 mA, HART
Subject to modifi cation
![Page 11: 100 YEARS Process-Instrumentation 1911 – 2011€¦ · 100 YEARS Process-Instrumentation 1911 – 2011 LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:16 Uhr Seite 1. Products](https://reader034.vdocuments.net/reader034/viewer/2022042309/5ed721e3c30795314c174191/html5/thumbnails/11.jpg)
Tailored custom solutions to meet every need.We are specialists in custom production of all kinds. Special material likeTitanium, Tantalum and Nickel – no problem. High pressures e.g. up to900 bar – no problem.With our team of experts we can solve nearly all measuring problems.
NOTES:
100 Years Process-Instrumentation1911 – 2011
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:18 Uhr Seite 11
![Page 12: 100 YEARS Process-Instrumentation 1911 – 2011€¦ · 100 YEARS Process-Instrumentation 1911 – 2011 LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:16 Uhr Seite 1. Products](https://reader034.vdocuments.net/reader034/viewer/2022042309/5ed721e3c30795314c174191/html5/thumbnails/12.jpg)
Robert-Perthel-Str. 9 · D-50739 Cologne/Germany · Phone +49 (221) 4 97 08-0 · Fax +49 (221) 4 97 08-178www.heinrichs.eu · [email protected]
Heinrichs Messtechnik GmbH
H e i n r i c h s w o r l w i d e
London
Brüssel
Paris
ArnhemErfurtNürnberg
Reutlingen
Lyon
Hofheim
SarajewoBudapest
Bukarest
Zagreb
Sofia
Belgrad
Stuttgart
Zürich
Bratislava
Mailand
KiewWien
PragWarschau
Xian
Pune
Bangkok
Ho Chi Minh CityHanoi
Beijing
Shanghai
Seoul
Taipei
Guangzhou
Detroit
Toronto
Pittsburgh
Phoenix
Mexico City
Monterrey
Teheran
Montreal
Barranquilla
Caracas
Casablanca
Bogota
Santo Domingo
Lima
Buenos Aires
Singapur
Sydney
Jakarta
Philadelphia
Santiago de Chile
Kuala Lumpur
Johor
Barcelona
Algier
Tunis
Cairo
Pune
Mumbay
Johannesburg
LP 2011 englisch:Programm-2007-1-gb 07.04.2011 12:18 Uhr Seite 12
Robert-Perthel-Str. 9 · D-50739 Köln/Germany · Tel. +49 (221) 4 97 08-0 · Fax +49 (221) 4 97 08-178www.heinrichs.eu · [email protected]
Heinrichs Messtechnik GmbH
Heinrichs Messtechnik weltweit
Produktion und Vertrieb Vertrieb
Hofheim Zürich Köln Arnhem Brüssel Mansfi eld
Stuttgart Sindelfi ngen Erfurt Usingen Mailand
Brno Warschau Wien
Bratislava Zagreb Budapest (Nyíregyháza) Sarajewo Belgrad Bukarest Sofi a Istanbul
Bangkok Xian Ho Chi Minh City Wuhan Tianjin
Paris Lyon
Barcelona Tunis
Querétaro
Seoul Shanghai Taipeh Guangzhou
Providence Medina Pittsburgh Detroit Charleston Cartagena Barranquilla Bogota
Kiew
Neu Delhi Pune
Kairo
Jakarta
Medellin Cali Lima
Buenos Aires
Santiago de Chile
Las Vegas
TorontoMontreal
Kuala Lumpur Singapur Johor
PÜ_Heinrichs_Umschlag_alle.indd 4 12.07.2013 07:38:47