10.01.03.162 (one way slab)

27
AHSANULLAH UNIVERSITY OF SCIENCE AND TECHNOLOGY Pre-stressed concrete lab CE 418 COURSE TEACHER Mr.Galib Muktadir & Sabreena N.Mouri DEPARTMENT OF CIVIL ENGINEERING

Upload: ananna-rashid

Post on 25-Jun-2015

246 views

Category:

Technology


1 download

DESCRIPTION

Ahsanullah University of Science and Technology Name:Mehrana rashid Ananna ID:10.01.03.162 Topic:One Way Slab 4th year,2nd semester

TRANSCRIPT

Page 1: 10.01.03.162 (one way slab)

AHSANULLAH UNIVERSITY OF SCIENCE AND TECHNOLOGY

Pre-stressed concrete lab CE 418

COURSE TEACHER

Mr.Galib Muktadir & Sabreena N.Mouri

DEPARTMENT OF CIVIL ENGINEERING

Page 2: 10.01.03.162 (one way slab)

MEHRANA RASHID

INTRODUCTION

I.D NO : 10.01.03.162

Page 3: 10.01.03.162 (one way slab)

NAME OF MY TOPIC

SLAB DESIGN:

ONE WAY SLAB

Page 4: 10.01.03.162 (one way slab)

1. Definition & types of slab2. Definition of one-way slab3. Figure of one-way slab4. Design considerations of one-way slab5. Approximate structural analysis6. Typical reinforcement in a one-way slab7. Summary of one-way slab design procedure8. Example of one-way slab

PRESENTATION OUTLINE

Page 5: 10.01.03.162 (one way slab)

FIRST WE WILL KNOW ABOUT SLABS; LIKE

•What is slab?

•What type of slabs there are?

Page 6: 10.01.03.162 (one way slab)

A slab is structural element whose thickness is small compared to its own length and width.

Slabs in Buildings are usually used to transmit the loads on floors and roofs to the supporting beams.

Page 7: 10.01.03.162 (one way slab)

One-way slab Two-way slab Flat plate Flat slab Grid or waffle slab

TYPES OF SLABS :

Page 8: 10.01.03.162 (one way slab)

A One Way Slab is simply a very wide beam that spans between supports.

When slab is supported on two opposite sides only, total load is carried along the perpendicular direction of supporting beams.

When slab is supported at all sides and length/width >2 of a slab panel, maximum load is carried along the short direction.

Main reinforcement is placed along the load carrying direction.

Main Reinft.

shri

nka

ge R

ein

ft.

L

S

Beam

Beam

ONE-WAY SLAB

Page 9: 10.01.03.162 (one way slab)

The slab is designed as a series of 1’-0” wide beam “strips”. The analysis is similar to rectangular beams, except the width b = 12” and the height is usually on the order of 4” →10”.

The main tension bars are usually #4, #5 or #6 bars. however, additional bars are placed perpendicular to the main tension bars to prevent cracking during the curing process. These bars are referred to as “shrinkage” or “temperature” bars and are also usually

#4 or #5 bars.

Page 10: 10.01.03.162 (one way slab)

A one-way slab is supported by parallel walls or beams, and the main tension reinforcing bars run parallel to the span. It looks like the following:

Page 11: 10.01.03.162 (one way slab)

Design considerations1- Minimum Thickness:To control deflection, ACI Code specifies minimum thickness values for one-way solid slabs, shown in the following Table.

Element

Simply supported

One End continuous

Both end continuous

Cantilever

One way slabs

L/20 L/24 L/28 L/10

Where L is the span length in the direction of bending.

Page 12: 10.01.03.162 (one way slab)

2- Design Concept:

One-way solid slabs are designed as a number of independent 1 ft or 12 “ wide strips which span in the short direction and supported on crossing beams.

1 f

t

S2S1

LS2S1

Page 13: 10.01.03.162 (one way slab)

3- Reinforcement Ratio: One-way solid slabs are designed as rectangular sections

subjected to shear and moment. Thus, the maximum reinforcement ratio is

4-Minimum reinforcement Shrinkage and temperature For fy = 40 to 50 ksi As(S&T) = 0.002bh� For fy = 60 ksi As(S&T) = 0.0018bh� � For fy > 60 ksi As(S&T) = (0.0018x60xbh)/fy >= 0.0014bh

tu

u

f

f

y

c

'

85.0 1max

Page 14: 10.01.03.162 (one way slab)

5- Spacing of Reinforcement Bars S=( 12 * as) / As here , as = area of the bar used , As = area of reinforcement 6- Loads Assigned to Slabs wu=1.2 D.L + 1.6 L.L

7-Minimum cover � ACI 7.7.71 (if not exposed to weather or in contact with soil) � ¾ in. for # 11 and smaller 1.5 in. for # 14 and # 18 bars

Page 15: 10.01.03.162 (one way slab)

Approximate Structural Analysis

Page 16: 10.01.03.162 (one way slab)

Typical Reinforcement in a one-way slab

Page 17: 10.01.03.162 (one way slab)

Example of one way slab

Page 18: 10.01.03.162 (one way slab)
Page 19: 10.01.03.162 (one way slab)
Page 20: 10.01.03.162 (one way slab)
Page 21: 10.01.03.162 (one way slab)
Page 22: 10.01.03.162 (one way slab)
Page 23: 10.01.03.162 (one way slab)

Reinforcement detailing

Page 24: 10.01.03.162 (one way slab)

1- Select representative 1ft wide design strip/strips to span in the short

direction.

2- Choose a slab thickness to satisfy deflection control requirements. When several numbers of slab panels exist, select the largest calculated thickness.

3- Calculate the factored load wu by magnifying service dead and live loads according to this equation wu=1.20wD +1.60wL .

4- Draw the shear force and bending moment diagrams for each of the strips.

Summary of One-way Slab Design Procedure

Page 25: 10.01.03.162 (one way slab)

5- calculate maximum moment Mu.

6- Flexural reinforcement ratio is calculated from the following equation ,

7-Compute the area of shrinkage reinforcement,

8-Draw a plan of the slab and representative cross sections showing the dimensions and the selected reinforcement.

εtεu

εu

f

'fβ0.85ρ

y

c1max

Page 26: 10.01.03.162 (one way slab)
Page 27: 10.01.03.162 (one way slab)

question