Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 1 of 23
Date: 15th March 2018
Approved by: Atta Subhan
Calibration Laboratory Accreditation No. ACL 0007
is accredited by the GCC Accreditation Center (GAC) in accordance with the recognized International Standard ISO/IEC 17025:2005, “General requirements for the competence of testing and calibration laboratories”
Arabcal Icon Technical Solutions WLL- Laboratory
Issue No: 1 Issue Date: 01.April.2018
Address.
Arabcal Icon Technical Solutions WLL,
Furoziya Street, Building number 8, near horse race course round about, Doha, Qatar
Contact: Mr. Eby Joy Tel: +97444168827 Fax: +97444019777
Email: [email protected]
Web Address: www.arabcal.com
Locations where calibration activities covered by the above Accreditation Standard are undertaken
1- address: Furoziya Street, Building number 8, near horse race course round about, Doha, Qatar
For the following scope:
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 2 of 23
Date: 15th March 2018
Approved by: Atta Subhan
Scope:
Guidance for Assessment Team on preparation of scope Here, please follow AC 10.7 chose the main calibration Category and sub-scope (red-liners in AC 10.7), below is an example:
1. Calibration 1.38 Instrument calibrators .01 D.C. voltage .02 A.C. voltage .11 D.C. current .12 A.C. current .51 Resistance
1.39 Indicating and recording instruments .01 D.C. voltmeters .02 A.C. voltmeters .03 D.C. ammeters .04 A.C. ammeters .09 Ohmmeters .10 LCR meters (Excluding Inductance) .30 Insulation resistance test equipment 1.41 Frequency and time measuring instruments and standards .01 Frequency meters
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 3 of 23
Date: 15th March 2018
Approved by: Atta Subhan
Scope details are as follows: Calibration field 1: (Electrical)
Measurand / Equipment Measuring Range CMC (k=2) Method (standard/guide + internal
procedure)
Permanent lab (P)
/ Client-site (S) *
Temperature Indicators- Thermocouple (mV Simulation)- Type K
(-140 to 1340) °C 0.25°C
Euramet cg-11, Version 2.0
Permanent Lab. (P)
Type J (400 to 750) °C 0.10°C
Type T (-250 to 400) °C 1.0°C
Type S (-50 to 1700)°C 1.0°C
Type N (-257 to 1300) °C 1.0°C
Type E (0 to 800)°C 0.20°C Permanent Lab. (P)
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 4 of 23
Date: 15th March 2018
Approved by: Atta Subhan
Temperature Indicators-RTD – simulation
(-200 to -80) ⁰C / RTD-100 Ω 0.10 ⁰C
> (-80 to 100) ⁰C / RTD-100 Ω 0.14 ⁰C
> (100 to 800) ⁰C / RTD- 100 Ω 0.46 ⁰C
(-200 to -80) ⁰C / RTD-200Ω 0.08 ⁰C
> (-80 to 100) ⁰C / RTD-200 Ω 0.08 ⁰C
> (100 to 630) ⁰C / RTD-200 Ω 0.32 ⁰C
(-200 to 100) ⁰C / RTD- 500 Ω 0.10 ⁰C
> (100 to 630) ⁰C / RTD-500 Ω 0.22 ⁰C
(-200 to 100) ⁰C / RTD-1000 Ω 0.08 ⁰C
> (100 to 630) ⁰C / RTD-1000 Ω 0.46 ⁰C
Euramet cg-11, Version 2.0
(-80 to 100) ⁰C / RTD-120 Ω 0.16 ⁰C
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 5 of 23
Date: 15th March 2018
Approved by: Atta Subhan
> (100 to 260) ⁰C / RTD-120 Ω 0.28 ⁰C
(-100 to 260) ⁰C / RTD-10 Ω 0.60 ⁰C
DC Voltage 0.001 V to 330 mV 35 10-6 U +4.3 µV
Internal procedure CI/01/M1;
Based on Euramet cg-15
Calibration of Meter >0.33 V to 3.3 V 34 10-6 U + 7.7 µV
U=measured value >3.3 V to 33 V 28 10-6 U + 67 µV
>33 V to 330 V 34 10-6 U + 0.65 mV
>100 V to 1020 V 35 10-6 U + 5.1 mV
Permanent Lab. (P)
AC Voltage 0.001 V to 330 mV
Calibration of Meters 10 Hz to 45 Hz 2.3 10-3U + 59 µV
U=measured value >45 Hz to 1 kHz 0.38 10-3U + 49 µV
>1 kHz to 20 kHz 0.92 10-3U + 75 µV
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 6 of 23
Date: 15th March 2018
Approved by: Atta Subhan
>0.33 V to 3.3 V
10 Hz to 45 Hz 2.3 10-3U + 0.44 mV
>45 Hz to 999 kHz 0.42 10-3U + 0.23 mV
>1 kHz to 20 kHz 0.96 10-3U + 0.35 mV
>20 kHz to 50 kHz 2.9 10-3U + 2.3 mV
>3.3 V to 33 V
Permanent Lab. (P)
10 Hz to 45 Hz 2.3 10-3U +3.9 mV
>45 Hz to 2 kHz 0.36 10-3U +2.3 mV
>1 kHz to 20 kHz 0.72 10-3U + 3.7 mV
>33 V to 330 V
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 7 of 23
Date: 15th March 2018
Approved by: Atta Subhan
30 Hz to 45 Hz 0.66 10-3U + 31 mV
>45 Hz to 1 kHz 0.41 10-3U + 22 mV
>1 kHz to 19.999 kHz 1.0 10-3U + 58 mV
>100 V to 1020 V
30 Hz to 45 Hz 0.67 10-3U + 0.26 V
>45 Hz to 1 kHz 0.39. 10-3U + 0.20 V
>1 kHz to 10 kHz 1.7 10-3U + 0.49 V
Permanent Lab. (P)
Calibration of Meters >0.0 mA to 3.3 mA 89 10-6U + 55 nA
U=measured value >3.3 mA to 33 mA 53 10-6U + 0.49 µA
>33 mA to 330 mA 92 10-6U + 3.5 µA
>0 A to 2.2 A 0.15 10-3U + 91 µA
>2.2 A to 11 A 0.45 10-3U + 0.50 mA
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 8 of 23
Date: 15th March 2018
Approved by: Atta Subhan
DC Current(using current coil)
20 A to 100 A 6.8 10-3I + 0.20 A
Calibration of Meters
U=measured value >100 A to 500 A
6.8 10-3U + 0.70 A
AC Current 2.5 µA to 200 µA
Calibration of Meters 10 Hz to 45 Hz 2.3 10-3U + 0.29 µA
U=measured value >45 Hz to 1 kHz 0.80 10-3U + 0.29 µA
Permanent Lab. (P)
>1 kHz tp 10 kHz 0.78 10-3U + 0.38 µA
0.03mA to 0.33 mA
10 Hz to 45 Hz 2.3 10-3U + 0.66 µA
>45 Hz to 1 kHz 0.65 10-3U + 0.59 µA
>1 kHz tp 10 kHz 0.54 10-3U + 2.0 µA
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 9 of 23
Date: 15th March 2018
Approved by: Atta Subhan
> 0.33mA to 3.3 mA
10 Hz to 45 Hz 2.3 10-3U + 6.6 µA
>45 Hz to 1 kHz 0.65 10-3U + 6.6 µA
>1 kHz to 10 kHz 5.5 10-3U + 5.9 µA
> 3.3mA to 33 mA
10 Hz to 45 Hz 2.3 10-3U + 66 µA
>45 Hz to 1 kHz 0.65 10-3U + 59 µA
Permanent Lab. (P)
>1 kHz to 10 kHz 6.6 10-3U + 0.15 mA
> 0.033 A to 2.2 A
10 Hz to 45 Hz 2.3 10-3U + 0.70 mA
>45 Hz to 1 kHz 0.98 10-3U + 0.64 mA
>1 kHz to 5 kHz 6.6 10-3U + 1.5 mA
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 10 of 23
Date: 15th March 2018
Approved by: Atta Subhan
> 2.2A to 11 A
30 Hz to 45 Hz 2.3 10-3U + 7 mA
>45 Hz to 100 Hz 0.88 10-3U + 4.9 mA
>100 Hz to 1 kHz 3.4 10-3U + 5.8 mA
AC Current(using coil) >20 A to 100 A
Calibration of Meters 30 Hz to 60 Hz 6.8 10-3U + 0.20 A
Permanent Lab. (P)
U=measured value >100 A to 500 A
30 Hz to 60 Hz 6.8 10-3U + 0.70 A
Resistance-2wire 0.2 Ω 5.0 mΩ
Calibration of Meters 1 Ω 5.0 mΩ
10 Ω 7.0 mΩ
100 Ω 11 mΩ
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 11 of 23
Date: 15th March 2018
Approved by: Atta Subhan
1 kΩ 0.10 Ω
10 kΩ 0.90 Ω
100 kΩ 9.0 Ω
1 MΩ 0.10 kΩ
10 MΩ 4.5 kΩ
100 MΩ 0.60 MΩ
Permanent Lab. (P)
Resistance 4-wire 0.1 Ω 0.10 mΩ
Calibration of Meters 10 Ω 6.0 mΩ
100 Ω 12 mΩ
1 kΩ 0.10 Ω
10 kΩ 0.90 Ω
100 kΩ 9.0 Ω
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 12 of 23
Date: 15th March 2018
Approved by: Atta Subhan
Capacitance @ 1kHz 1 nF 6.0 pF
10 nF 40 pF
20 nF 0.10 nF
50 nF 0.20 nF
100 nF 0.30 nF
Permanent Lab. (P)
1 uF 10 nF
10 uF 0.10 µF
100 uF 0.72 µF
1 mF 0.01 mF
Frequency 1 Hz to 100 Hz 2.0 10-6f+ 18 µHz
>100 Hz to 1 k Hz 2.0 10-6f+ 90 µHz
>1 kHz to 10 kHz 2.0 10-6f+ 0.90
mHz
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 13 of 23
Date: 15th March 2018
Approved by: Atta Subhan
>10 kHz to 20 kHz 2.0 10-6f+ 0.60
mHz
>20 kHz to 50 kHz 2.0 10-6f+ 1.7 mHz
>50 kHz to 100 kHz 2.0 10-6f+ 30 mHz
>100 kHz to 1 MHz 2.0 10-6f+ 91 mHz
Insulation Resistance 10 kΩ 10 Ω
SANAS Guideline TG-02-01;
Internal procedure CI/01/I2 Permanent Lab. (P)
100 kΩ 0.10 kΩ
1 MΩ 1.0 kΩ
5 MΩ 10 kΩ
10 MΩ 0.13 MΩ
50 MΩ 0.59 MΩ
100 MΩ 1.2 MΩ
400 MΩ 5.6 MΩ
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 14 of 23
Date: 15th March 2018
Approved by: Atta Subhan
1 GΩ 10 MΩ
2 GΩ 50 MΩ
4 GΩ 0.24 GΩ
10 GΩ 0.58 GΩ
Direct Method using Electrical test calibrator
Permanent Lab. (P)
100 GΩ 5.7 GΩ
RCD Trip Current 10 mA @ 50 Hz 0.22 mA
30 mA @ 50 Hz 0.51 mA
90 mA @ 50 Hz 1.3 mA
100 mA @ 50 Hz 1.5 mA
110 mA @ 50 Hz 1.6 mA
150 mA @ 50 Hz 2.8 mA
300 mA @ 50 Hz 4.9 mA
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 15 of 23
Date: 15th March 2018
Approved by: Atta Subhan
400 mA @ 50 Hz 6.3 mA
500 mA @ 50 Hz 7.7 mA
1000 mA @ 50 Hz 15 mA
2000 mA @ 50 Hz 29 mA
Permanent Lab. (P)
RCD Trip Time 20 ms 0.69 ms
40 ms 0.69 ms
200 ms 0.69 ms
390 ms 8.0 ms
Electrical-Measurement
DC Voltage 0.001 V to 0.1 V 21 10-6U +2.6 µV
Comparison using 6.5 Digit DMM- CI/01/EC1 Internal procedure
Calibration of Calibrators >0.1 V to 1 V 10 10-6U + 6.5 µV
U=measured value >1 V to 10 V 10 10-6U + 38 µV
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 16 of 23
Date: 15th March 2018
Approved by: Atta Subhan
>10 V to 100 V 25 10-6U + 0.74 µV
>100 V to 1000 V 25 10-6U + 2.6 mV
AC Voltage 0.001 V to 0.1 V
Permanent Lab. (P)
Calibration of Calibrators 20 Hz to 50 Hz 2.9 10-3U + 4.8 µV
U=measured value >50 Hz to 100 Hz 0.76 10-3U + 11 µV
>100 Hz to 2 kHz 0.16 10-3U + 18 µV
>2 kHz to 10 kHz 0.16 10-3U + 18 µV
>10 kHz to 30 kHz 0.16 10-3U + 38 µV
>30 kHz to 100 kHz 3.2 10-3U + 55 µV
>0.1 V to 1 V
20 Hz to 50 Hz 2.9 10-3U + 27 µV
>50 Hz to 100 Hz 0.79 10-3U + 23 µV
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 17 of 23
Date: 15th March 2018
Approved by: Atta Subhan
>100 Hz to 2 kHz 0.21 10-3U + 54 µV
>2 kHz to 10 kHz 0.21 10-3U + 54 µV
>10 kHz to 30 kHz 0.25 10-3U + 0.10 mV
Permanent Lab. (P)
>30 kHz to 100 kHz 3.5 10-3U + 41 µV
>1 V to 10 V
20 Hz to 50 Hz 2.9 10-3U + 0.27 mV
>50 Hz to 100 Hz 0.80 10-3U + 0.21 mV
>100 Hz to 2 kHz 0.33 10-3U + 0.41 mV
>2 kHz to 10 kHz 0.45 10-3U + 0.33 mV
>10 kHz to 30 kHz 0.55 10-3U + 0.72 mV
>30 kHz to 100 kHz 3.5 10-3U + 0.31 mV
>10 V to 100 V
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 18 of 23
Date: 15th March 2018
Approved by: Atta Subhan
20 Hz to 50 Hz 2.9 10-3U + 2.7 mV
>50 Hz to 100 Hz 0.80 10-3U + 2.9 mV
Permanent Lab. (P)
>100 Hz to 2 kHz 0.56 10-3U + 3.7 mV
>2 kHz to 10 kHz 0.45 10-3U + 4.4 mV
>10 kHz to 30 kHz 0.55 10-3U + 8.1 mV
>100 V to 750 V
20 Hz to 50 Hz 2.9 10-3U + 4.5 mV
>50 Hz to 100 Hz 1.1 10-3U + 11 mV
>100 Hz to 2 kHz 0.53 10-3U + 47 mV
>2 kHz to 10 kHz 0.51 10-3U + 0.21 V
DC Current 0.000 µA to 200 µA 0.40 10-3U + 0.04 µA
Calibration of Calibrators >0.2 mA to 2 mA 0.40 10-3U + 0.05 µA
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 19 of 23
Date: 15th March 2018
Approved by: Atta Subhan
U=measured value >2 mA to 10 mA 0.40 10-3U + 0.43 µA
>10 mA to 100 mA 0.43 10-3U + 4.4 µA
Permanent Lab. (P)
>0.1 A to 3 A 0.86 10-3U + 63 µA
AC Current 0.2 µA to 100 µA
Calibration of Calibrators 20 Hz to 50 Hz 4.0 10-3U + 4.6 nA
U=measured value >50 Hz to 200 Hz 2.3 10-3U + 7.8 nA
>200 Hz to 1 kHz 4.6 10-3U + 4.1 nA
>1 kHz to 5 kHz 5.2 10-3U + 0.15 µA
>0.1 mA to 1 mA
20 Hz to 50 Hz 4.0 10-3U + 4.6 nA
>50 Hz to 200 Hz 2.3 10-3U + 7.8 nA
>200 Hz to 1 kHz 4.6 10-3U + 4.1 nA
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 20 of 23
Date: 15th March 2018
Approved by: Atta Subhan
>1 kHz to 5 kHz 5.2 10-3U + 0.15 µA
Permanent Lab. (P)
>1 mA to 10 mA
20 Hz to 50 Hz 3.5 10-3U + 44 nA
>50 Hz to 200 Hz 1.7 10-3U + 82 nA
>200 Hz to 1 kHz 1.3 10-3U + 98 nA
>1 kHz to 5 kHz 1.4 10-3U + 60 µA
>10 mA to 100 mA
20 Hz to 50 Hz 3.5 10-3U + 0.44 µA
>50 Hz to 200 Hz 1.7 10-3U + 0.82 µA
>200 Hz to 1 kHz 1.3 10-3U + 0.98 µA
>1 kHz to 5 kHz 1.4 10-3U + 0.53 µA
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 21 of 23
Date: 15th March 2018
Approved by: Atta Subhan
>0.1 A to 3 A
20 Hz to 50 Hz 3.5 10-3U + 4.1 mA
Permanent Lab. (P)
>50 Hz to 200 Hz 1.7 10-3U + 7.6 mA
>200 Hz to 1 kHz 1.4 10-3U + 9.1 mA
>1 kHz to 5 kHz 1.4 10-3U + 2.6 mA
Resistance 0.1 Ω to 10 Ω 16 10-6U + 0.25
mΩ
Calibration of Calibrators, Decade resistance Box, Capacitance, Inductance box
>10 Ω to 100 Ω 19 10-6U + 1.2 mΩ
U=measured value >100 Ω to 1 kΩ 8.4 10-6U + 6.4 mΩ
>1 kΩ to 10 kΩ 8.4 10-6U + 64 mΩ
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 22 of 23
Date: 15th March 2018
Approved by: Atta Subhan
>10 kΩ to 100 kΩ 39 10-6U + 0.60 Ω
>100 kΩ to 1 MΩ 72 10-6U + 30 Ω
Permanent Lab. (P)
>1 MΩ to 10 MΩ 0.29 10-3U + 98 Ω
>10 MΩ to 100 MΩ 0.63 10-3U + 4.0 kΩ
Frequency @1 Hz 0.35 10-3 f + 0.16
µHz
Calibration of Calibrators, >1 Hz to 10 Hz 0.35 10-3 f + 1.6
µHz
f =measured value >10 Hz to 100 Hz 0.35 10-3 f + 19
µHz
>100 Hz to 1 kHz 0.35 10-3 f + 0.16
mHz
>1 kHz to 10 kHz 0.35 10-3 f + 1.6
mHz
>10 kHz to 100 kHz 0.35 10-3 f + 20
mHz
>100 kHz to 300 kHz
0.35 10-3 f + 20 mHz
Accreditation Procedures
GAC
10.15 Scope of Accreditation
Issue No: 1/ Issue Date: 01.April.2018
Accreditation Manager: Hamza Khan
ACCREDITED
CALIBRATION ISO/IEC 17025:2005
No. ACL 0007
Version: 1.0 Page 23 of 23
Date: 15th March 2018
Approved by: Atta Subhan
DC Voltage (Using Voltage Divider)
0 V to 1000 V 0.10 10-3U + 24
mV
Calibration of Calibrators >1000 V to 5000 V 0.24 10-3U
AC Voltage(Using Voltage Divider)
0 to 1000 V 1.0 10-3U + 0.20 V
Calibration of Calibrators >1000 V to 5000 V 1.0 10-3U + 0.20 V
Note: the text in blue indicates the new scope OR update in the Edition of a test method in this issue of the scope of accreditation. *: Put only ‘P’, ‘S’ or ‘P and S’
END