www.dsc.com

Wiring a keypad with a Zone input

Page 3: 11) Keypad PGM - Zone [Compatibility Mode]1

www.dsc.com

Wiring a keypad with a Zone input

Keybus to

the panel

Page 4: 11) Keypad PGM - Zone [Compatibility Mode]1

www.dsc.com

Wiring a keypad with a Zone input

Page 5: 11) Keypad PGM - Zone [Compatibility Mode]1

www.dsc.com

Wiring a keypad with a Zone input

Page 6: 11) Keypad PGM - Zone [Compatibility Mode]1

www.dsc.com

ProgrammingSection [000] Sub-Section [0]

Assign an unique Slot # to the keypad.

Section [001- 004]

Define the zone.

Section [202 – 265]

Verify the zone is active.

Section [020]

Program the keypad slot with the zone number.

Page 7: 11) Keypad PGM - Zone [Compatibility Mode]1

www.dsc.com

Wiring a keypad with a PGM output

Keybus to

the panel

Page 8: 11) Keypad PGM - Zone [Compatibility Mode]1

www.dsc.com

RM-1

Wiring a keypad with a PGM output

+

-

Page 9: 11) Keypad PGM - Zone [Compatibility Mode]1

www.dsc.com

RM-1

+

Wiring a keypad with a PGM output

-

N/O

C

N/C

Page 10: 11) Keypad PGM - Zone [Compatibility Mode]1

www.dsc.com

ProgrammingSection [009 - 011]

Define the PGM.

Enter into Keypad Programming (*)

Section [077]

Toggle Option 3 ON.

Section [080]

Select the PGM # to follow.

Page 11: 11) Keypad PGM - Zone [Compatibility Mode]1

www.dsc.com

Programming the Keypad as a Low Temp Sensor

Keybus to

the panel

Page 12: 11) Keypad PGM - Zone [Compatibility Mode]1

www.dsc.com

Programming the Keypad as a Low Temp Sensor

No additional

wiring needed

Alarm – 43o

Reset – 48o

Page 13: 11) Keypad PGM - Zone [Compatibility Mode]1

www.dsc.com

ProgrammingSection [000] Sub-Section [0]

Assign an unique Slot # to the keypad.

Section [001- 004]

Define the zone.

Section [202 – 265]

Verify the zone is assigned to a partition.

Section [020]

Program the keypad slot with the zone number.

Page 14: 11) Keypad PGM - Zone [Compatibility Mode]1

www.dsc.com

ProgrammingEnter into Keypad Programming (*)

Section [077]

Toggle Option 3 ON.

Toggle Option 8 ON.

Low Temp Sensor is built into the keypad – no wiring required.