Recirculating Chiller F-305, F-308, F-314 Technical data sheet The BUCHI recirculating chillers are meant to be used with laboratory equipment that requires coolant flow such as rotary evaporators, parallel evaporators, Kjeldahl- and extraction products. The F-300 line is specifically designed for seamless integration into a BUCHI Rotavapor® R-300 system. The temperature can conveniently be set by the interface. Furthermore, it offers ECO-mode, temperature lock and instant start with dynamic pressure adjustment without wait- ing until the chiller reaches its set temperature. 11595224F en Recirculating Chiller F-305, F-308, F-314 02.2022 Technical data are subject to change without notice Quality Systems ISO 9001

Upload: others

Post on 27-May-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 11595224E en Recirculating Chiller F-305, F-308, F-314 06

Recirculating Chiller F-305, F-308, F-314Technical data sheet

The BUCHI recirculating chillers are meant to be used with laboratory equipment that requirescoolant flow such as rotary evaporators, parallel evaporators, Kjeldahl- and extraction products.The F-300 line is specifically designed for seamless integration into a BUCHI Rotavapor®R-300 system. The temperature can conveniently be set by the interface. Furthermore, it offersECO-mode, temperature lock and instant start with dynamic pressure adjustment without wait-ing until the chiller reaches its set temperature.

11595224F en Recirculating Chiller F-305, F-308, F-314 02.2022Technical data are subject to change without notice

Quality Systems ISO 9001

Page 2: 11595224E en Recirculating Chiller F-305, F-308, F-314 06

2

OverviewThe Recirculating Chiller F-305 / F-308 / F-314 cover a temperature range of -10 to + 25 °C. The chillers differ in thecolling capacity to support various laboratory instruments.

Recommended chiller when working at 15 °C cooling and 20 °C ambient temperature

F-305 F-308 F-314

Cooling capacity at 15 °C 550 W 900 W 1400 W

Supported lab-size rotary evaporator 1 2 3 – 4

Supported parallel evaporator - 1 2

Supported extraction system - 1 2

Supported Kjeldahl products - 1 stand-alone 1 sampler system

Recommended chiller when working at other cooling temperatures

The following graph shows the relation between cooling capacity and temperature at 25 °C ambient conditions; thelower the temperature, the lower the cooling capacity. In addition to the ambient temperature, the cooling capacity isinfluenced by humidity, tubing length, tubing diameter, etc.

200

020 15 10 5 0 -5 -10

400

600

800

1000

1200

1400

1600

1800

F-305

F-308

F-314

Temperature [°C]

Coolin

g c

ap

acity

[W]

1 2

3

Typically required cooling capacity for laboratory instruments:

Rotary evaporator: 400 W

Extraction units: 550 W

Kjeldahl unit: 700 W

Parallel evaporation: 600 W

Examples:

1 Distillation with one rotary evaporator at 10 °C F-305

2 Distillation with one rotary evaporator at 0 °C F-308

3 Distillation with two rotary evaporators at 5 °C F-314

Page 3: 11595224E en Recirculating Chiller F-305, F-308, F-314 06

3

Order codeChoose the configuration according to your needs:

Recirculating Chiller Type

1 1 F 3 0

F-305 (550 W at 15 °C)05F-308 (900 W at 15 °C)08F-314 (1400 W at 15 °C)14

Voltage230 V1115 V2

Scope of deliveryAll configurations are supplied ready to use.

F-305 F-308 F-314

Hose clamp 4 4 4

Power cord 1 1 1

Control cable, 2 m 1 1 1

Hose barb, Ø 8 mm 2 2 -

Hose barb, Ø 9.5 mm - 2 2

Hose barb, Ø 13.5 mm - - 2

Page 4: 11595224E en Recirculating Chiller F-305, F-308, F-314 06

4

Technical data

Recirculating Chiller

F-305 F-308 F-314

Dimensions (W x D x H) 280x 500 x 400mm 400 x 500 x 580 mm 400 x 500 x 670 mm

Weight 31 kg 41 kg 52 kg

Cooling capacity at 15 °C* 550 W 900 W 1400 W

Cooling capacity at 10 °C* 440 W 730 W 1150 W

Cooling capacity at 0 °C* 250 W 450 W 720 W

Cooling capacity at -10 °C* 80 W 180 W 350 W

Temperature range -10 to +25 °C -10 to +25 °C -10 to +25 °C

Heating emission 750 W 1400 W 2100 W

Power consumption 800 W 1100 W 1500 W

Voltage 230 V AC ± 10 % 115 VAC ± 10 %

230 V AC ± 10 % 115 VAC ± 10 %

230 V AC ± 10 %115 VAC ± 10 %

Frequencyat 230 Vat 115 V

50 - 60 Hz60 Hz

50 - 60 Hz60 Hz

50 - 60 Hz60 Hz

Temperature reading resolution 0.1 °C 0.1 °C 0.1 °C

Hysteresis ± 1 °C ± 1 °C ± 1 °C

Refrigerant R134a R134a R134a

Tank capacity 3.0 L 4.5 L 6.5 L

Tubing connector 8 + 9.5 mm 8 + 9.5 mm 9.5 + 13.5 mm

Pump pressure 0.6 bar 0.6 bar 1 bar

Pump delivery rate 2.5 L/min 3 L/min 11 L/min

Overvoltage category II II II

Display Digital Digital Digital

* Measured at 20°C ambient temperature.

Compatibility and communication requirements with a F-305 / F-308 / F-314

Interface /

Vacuum Controller

Compatibility / Mode Communication requirements

I-300 / I-300 Pro compatiblecontrolled

VacuBox2x Communication cable. BUCHI COM 6p:11058705 (0.3 m), 11058707 (1.8 m),11058708 (5 m) or 11064090 (15 m)Power is supplied through connection with otherappropriate peripherals.

I-100 compatibleon/off

Communication cable. Mini-DIN 8p:11060882 (0.6 m) or 038010 (1.5 m)Power adapter (11060669)

V-850 / V-855* compatibleon/off

Communication cable. Mini-DIN 6p to RJ45 11060649(1.5 m) or 11064104 (3 m)Power adapter (11060669)

Page 5: 11595224E en Recirculating Chiller F-305, F-308, F-314 06

5

Interface /

Vacuum Controller

Compatibility / Mode Communication requirements

V-800 / V-805 - -

* Vacuum Controller V-850/V-855 only communicates with the Recirculating Chiller F-305/F-308/F-314 when firmwareversion 3.0 (or newer) is installed.

Explanation of terms

speed controlled Recirculating chiller is turned on/off and the temperature can be set via the interface.The actual temperature is displayed on the interface. Additional features when thesystem is operating in „controlled“ mode are listed as follows.

on/off Recirculating chiller is automatically turned on/off via the interface.

- Connection not possible.

A VacuBox is included when ordering Rotavapor® R-300 with an Interface I-300 or Interface I-300 Pro compatbilitypack.

Page 6: 11595224E en Recirculating Chiller F-305, F-308, F-314 06

6

Recirculating Chiller F-305 / F-308 / F-314 featuresThe Recirculating Chillers F-305 / F-308 / F-314 offer various features when operating stand-alone or as part of a Ro-tavapor® R-300 system in conjunction with the Interface I-300 or I-300 Pro.

Feature Description With Interface

Firmware update With the BUCHI Monitor App and BUCHI BluetoothDongle, firmware updates can easily be done by the userat no costs.

Temperature setting onchiller

Set the temperature in 0.1 °C increments using thenavigation knob. Actual and set temperatures are shownon the integrated display.

Temperature lock Lock the set temperature with a push of the navigationknob to avoid unintentional changes.

Remote control withinterface

In addition to the setting of the chiller, the temperature canconveniently be set on the central interface thus showingall process parameters at a glance.

Remote monitoring The BUCHI Monitor App for PCs and mobile devices offerslive views and graphical displays of process parameters,as well as push notifications when an action is required, todrastically reduce the hands-on time at the instrument andfree valuable time for other tasks.

Dynamic operation The distillation process can be started instantly whenusing the solvent library mode. While the chiller reaches itsset temperature, the vacuum is dynamically adjusted.

Automatic stop The chiller can be configured to stop automatically whenthe distillation process is terminated.

ECO-mode Alternatively to the automatic stop the ECO-modeswitches the chiller into a stand-by mode when not in use.The temperature increases by a definable ∆T to be cooleddown to the set temperature periodically (see graphbelow).

Eco-mode

Chiller off

Distillation 1 Distillation 2ECO-mode

Chiller off Chiller off

∆T ∆T ∆T

Time

Tem

pera

ture

Page 7: 11595224E en Recirculating Chiller F-305, F-308, F-314 06

7

Feature comparison ( F-305 / F-308 / F-314 and Interface)

Features I-300 Pro /I-300

I-100 V-850 /V-855

V-800 /V-805

Withoutinterface

Power saving mode ● ●*

Automatic stop ● ●Dynamic distillation (only when connected toRotavapor® R-300 and vacuum pump)

Remote monitoring ●

Page 8: 11595224E en Recirculating Chiller F-305, F-308, F-314 06

8

All recirculating chillers at a glanceThe BUCHI recirculating chiller portfolio is completed with the F-100 line. The following table provides an overview ofthe different features.

Recirculating Chiller F-305

RecirculatingChiller F-100

RecirculatingChiller F-105

START

STOP

Recirculating Chiller F-308

Recirculating Chiller F-314

F-100300 W / 10 °C

F-105530 W / 15 °C

F-305550 W / 15 °C

F-308900 W / 15 °C

F-3141400 W / 15 °C

F-100 F-105 F-305 F-308 F-314

Cooling capacity at 15 °C 400 W 530 W 550 W 900 W 1400 W

Temperature range Fix at 10 °C –10 °C to

+25 °C

–10 °C to

+25 °C

–10 °C to

+25 °C

–10 °C to

+25 °C

Eco mode to save energy - - • • •

Temperature lock - - • • •

Recommended BUCHI Ro-tavapor® line

Rotavapor®R-100

Rotavapor®R-100

Rotavapor®R-300

Two Rotava-por® R-300

Two Rotava-por® R-300

ON/OFF control via inter-face on recom. Rotavapor®

- • • • •

Temperature setting via in-terface on recom. Rotava-por®

- - • • •

Other applications Small distillationapparatus

Small distillationapparatus

Small distillationapparatus

Kjeldahl

Extraction

Parallel evapora-tor

Parallel evapora-tor at low tem-

perature

Kjeldahl systems

Page 9: 11595224E en Recirculating Chiller F-305, F-308, F-314 06

9

Spare parts and accessories

Communication cable

Order no. Image

Communication cable. BUCHI COM, 1.8 m, 6p

Enables connection between Rotavapor® R-300 / R-220 Pro, InterfaceI-300 / I-300 Pro, Vacuum Pump V-300 / V-600, Recirculating Chiller F-3xx,VacuBox and LegacyBox.

11058707

Communication cable. BUCHI COM, 5.0 m, 6p

Enables connection between Rotavapor® R-300 / R-220 Pro, InterfaceI-300 / I-300 Pro, Vacuum Pump V-300 / V-600, Recirculating Chiller F-3xx,VacuBox and LegacyBox.

11058708

Communication cable. BUCHI COM, 15 m, 6p

Enables connection between Rotavapor® R-300 / R-220 Pro, InterfaceI-300 / I-300 Pro, Vacuum Pump V-300 / V-600, Recirculating Chiller F-3xx,VacuBox and LegacyBox.

11064090

Communication cable. Mini-DIN 6p to RJ45, 1.5 m

Connection between Vacuum Controller V-850 / V-855 and Vacuum PumpV-300 / V-600 or between Vacuum Controller V-850 / V-855, Interface I-100and Recirculating Chiller F-305 / F-308 / F-314.

11060649

Communication cable. Mini-DIN 6p to RJ45, 3 m

Connection between Vacuum Controller V-850 / V-855 and Vacuum PumpV-300 / V-600 or between Vacuum Controller V-850 / V-855, Interface I-100and Recirculating Chiller F-305 / F-308 / F-314.

11064104

Tubing

Order no.

Tubing. Nylflex, PVC-P, Ø8/14 mm, transparent, per m 004113

Insulation

Order no. Image

Hose insulation, Kaiflex, 11/23 mm, 1 m, black 028696

Hose insulation, Kaiflex, 16/27 mm, 2 m, black 11056888

Page 10: 11595224E en Recirculating Chiller F-305, F-308, F-314 06

10

Further accessories

Order no. Image

BUCHI Bluetooth® Dongle, connects instrument to smartphone viaBluetooth®

Needed for firmware updates and eSupport.

11067770

Coupling, set. Quick-release coupling, 8 mm, set of 2

Use: connection of two cooling tubes together.

042885

Distribution piece. T-piece incl. shut off valve, hose barb Ø 9 mm

Use: to connect two peripherals with one recirculating chiller

037742

Spare parts

Order no. Image

Hose barb, 8 mm 11062530

Hose barb, 9.5 mm 046792

Hose barb, 13.5 mm 040329

Union nut, M16x1, Rf, for hose barbs 019889

Hose clip, 8-16 mm 022352

Page 11: 11595224E en Recirculating Chiller F-305, F-308, F-314 06

11

Order no. Image

Y-connector, PP, 8 mm 011043

Y-connector, PP, 12 mm 11058358

Power cords

Order no.

Power cord, 3-pin, type CH 010010

Power cord, 3-pin, type DE 010016

Power cord, 3-pin, type GB 017835

Power cord, 3-pin, type AU 017836

Power cord, 3-pin, type US 010020

Power cord, 3-pin, type US for F-314 11061527

Power cord, 3-pin, type IND 11060536

Power cord, 3-pin, type JP 11061564