117 1892-2009 E-Motions by HEW ! Explosion-protected electric motors

Upload: ledang

Post on 23-Jan-2019

215 views

Category:

Documents


0 download

TRANSCRIPT

1171892-2009

E-Motions by HEW !

Explosion-protected electric motors

Herforder ElektromotorenwerkeGmbH & Co. KG

Goebenstraße 10632051 HerfordGermany

tel +49(0) 5221 5904-41fax +49(0) 5221 5904-34 [email protected]

This issue replaces all prior catalogues. Subject to change without notice. Issue 03/2009

1

2

3

4

6

5

Planning section

Explosion-protected three-phase A.C. motors ( single-speed )

Explosion-protected three-phase A.C. motors ( pole changing )

Explosion-protected three-phase A.C. motors ( single-speed ), operation on inverter

Dimension sheets

Construction type B3 5.1-5.2Construction type B5 5.3Construction type B14 5.4Construction type B35 5.5-5.6Construction type B34 5.7

Dimension sheets - customized motors

Brake motors 6.1Motors with forced ventilation 6.2Motors with encoder system 6.3Motors with motor cable 6.4

Three-phase A.C. motors

HEW DEx series

Categories

Electric motors- Planning section -

1/1

Three-phase A.C. motors

HEW DEx series

Overview of content in the planning section

Overview of production range 1.2Ignition protection types for electrical machines 1.3Explosion protection 1.4-1.6Overview of EC type-examination certificates 1.7

Mechanical designConstruction types 1.8-1.9Protection types 1.9Housing versions / flange variants 1.10-1.11Bearings 1.12Shaft ends 1.12Radial and axial forces 1.13-1.15Bearing lubrication 1.16Position of terminal box and cable entries 1.17-1.18Noise and vibration 1-19

Electrical designPower, voltage and frequency 1.20Heating and thermal classes 1.20Connections 1.20Overload 1.20Installation instructions 1.20Rotation 1.20Earthing and protective ground conductor connection 1.20Operation on frequency inverter 1.21Motor protection 1.22Cooling (ventilation) 1.22Stationary motor heating 1.22

Special versionsMotors with brake 1.23Motors with encoder 1.23Customized versions 1.24

1/2

Three-phase A.C. motors

HEW DEx series

HEW production range

HEW have been producing asynchronous motors for over 115 years. Our production range includes the following:

• Explosion-protected three-phase A.C. motors

• Explosion-protected three-phase A.C. motors with brake

• Standard three-phase A.C. motors (see catalogue series R)

• Standard pole-changing three-phase A.C. motors (see catalogue series R)

• Standard pole-changing three-phase A.C. motors fan drives (see catalogue series R)

• Reluctance motors (see catalogue series R)

• Single-phase motors (see catalogue series R)

• Brake motors (see catalogue series R)

• Rotary field magnets (see catalogue series R)

Our motors are suitable for inverter operation due to a high-grade insulation system. They are produced in thermal class F and fitted with PTC - resistor as standard (other temperature monitoring elements available on request).

The use of three-phase A.C. motors in demanding drive systems often requires the installation of feedback elements. HEW can also supply motors with incremental encoders on request from the customer. These encoders can be fitted to either explosion-protected three-phase A.C. motors or explosion-protected three-phase A.C. brake motors.

The motors are produced with protection class IP 55 as standard. Higher protection classes can be optionally supplied. (see page 1/9).

Versions produced in line with other standards, regulation and directive (e.g. GOST-R, VIK or GL) can be supplied on request.

Primer / lacquerHEW motors are provided with a primer as standard. The primer is a polyacrylic-based dual-component product and low in solvent content. The quick-drying primer coat can be applied as an undercoat, primer or primer filler to all metallic surfaces.

The motors can also be supplied with synthetic resin lacquer (RAL table) on request. Special lacquers with dual-component lacquers are also available.

1/3

1

Three-phase A.C. motors

HEW DEx series

Ignition protection types for electrical machines

Ignition protection type code letter

Constructional regulation Protection concept Application

Pressurised enclosure "d" EN 60079-1

Equipment for zone 1+2 1)

All parts which are ignition sources are contained in a pressure-tight housing, the seal is a spark-proof gap, so that in case of explosion in an explosive atmosphere on the inside of the housing, it will not be transferred to the surrounding explo-sive atmosphere.

All motor types e.g.:- Squirrel-cage motors- Slip ring motors- Collector motors

For all operating modes S1 to S10, for all difficult start-up conditions and speed-adjust-able drives

Increased safety "e" EN 60079-7

Equipment for zone 1+2 1)

This is where measures have to be taken which safely prevent the production of sparks, light arcs and inadmissible heating during proper operation of the equipment.

Squirrel-cage motors with adapted motor protection switch only. The specified tE times must be adhered to.

Ignition protection type "n"

EN 60079-15

Equipment for zone 2 1)

No sparks, light arcs or inadmissible temperatures occur operationally.If sparks, light arcs or inadmissible temperatures arise on the inside of the equipment, the housings, includ-ing the terminal box, must be con-structed with protection class IP54 which with overpressure of 4 mbar need more than 30 s to drop to 2 mbar (vapour-proof) or the housings and the terminal box are pressurised in a simple way.

All motor types e.g.:- Squirrel-cage motors - Slip ring motors- Collector motors etc. with motor protection switch and overpressure monitoring.

Prevention of the escape of operationally generated sparks. Manufacturer's infor-mation on these measures.

Dust protection EN 61241-0EN 61241-1(EN 50281)

Equipment for zone 21+22 2)

The ignition protection type is based on limitation of the maximum sur-face temperature of the housing and the restriction of the penetration of dust through the use of "dust-tight" or "dust-proof" housing.

All electric motors with protection provided by the housing with limitation of the surface temperature.

EN 60079-14, Electrical apparatus for explosive gas atmospheres - electrical installations in hazardous areas (other than 1) mines)EN 61241, Electrical apparatus for use in the presence of combustible dust2)

1/4

Three-phase A.C. motors

HEW DEx series

Gas explosion protection

Ignition temperature - Temperature classNumerous factors, such as size, shape, type and quality of the surface, influence the ignition temperature. IEC; CENELEC and other standards authorities have agreed on a process set out in IEC 60079-4 for determining the ignition temperature which comes very close to the lowest, practically possible value. It allocates gasses and vapours to temperature classes. These temperature classes are used to construct electrical equipment and other technological installations to rule out the possibility of a surface temperature ignition. The standards set out the permissible ex-ceedances and compulsory lower deviations from these control values.The normal version of the motors is equivalent to the highest group IIC and the temperature class T4 which include all lower groups and temperature classes. Motors in temperature class T4 deliver the output as standard motors without explosion protection of the same construction size. On request, motors can also be supplied in temperature classes T5 and T6 in which case the permitted housing temperature has to be taken into account and the rated power adjusted as necessary.

Temperature class Ignition temperature range of the mixture

Permitted surface temperature of the electrical equipment

Permitted tempera-ture increase

T1 > + 450 °C + 400 °C + 410°CT2 > + 300...< + 450°C + 300 °C + 260°CT3 > + 200...< + 300°C + 200 °C + 160°CT4 > + 135...< + 200°C + 135 °C + 95 °CT5 > + 100...< + 135°C + 100 °C + 60 °CT6 > + 85... < + 100°C + 85 °C + 45 °C

Examples of the classification of gasses and vapours in temperature classes and explosion subgroups.T1 T2 T3 T4 T5 T6

IIA Methane Propane Benzine Acetaldehyde

IIB Ethylene Diethyl ether

IIC Hydrogen Acetylene Carbon disul-phide

Dust explosion protection

Surface temperature - Protection classAn essential characteristic of dust explosion protection is the IP protection class. The motor is subject to different requirements for dust-tightness depending on the ambient conditions. The limitation of the surface temperature of motors to a value which is below the ignition and smouldering temperature of the present dust is important to dust explosion protection. Location Existence of a

explosive dusty atmosphere

occasional rare or fleeting rare or fleeting

Type of dust all types conductive non-conductiveZone 21 22 22

Equipment Device group II II IIDevice category 2D 2D 3DProtection class IP65 IP65 IP55TemperatureHousing temperature

max. 135°C max. 135°C max. 135°C

Certification EC type examination certificate for the testing centre

EC type examination certificate for the testing centre

EC declaration of conform-ity of the manufacturer

1/5

1

Three-phase A.C. motors

HEW DEx series

Permitted use of motors as per marking, depending on zone allocation

Group Category Zone allocation Definition Certificationobligation

For combustible gasses, vapours and mistII 1G* 0 Zone 0 includes areas in which an explosive atmosphere which

arises constantly, long-term or frequently due to a mixture of air and gasses, vapours or mist.

Yes

II 2G 1 Zone 1 includes areas in which an explosive atmosphere is ex-pected to arise occasionaly due to gasses, vapours or mist.

Yes

II 3G 2 Zone 2 includes areas in which an explosive atmosphere is not expected to arise from gasses, mists or vapours but if it does arise, it is likely to be rare and for a short period of time.

No

For combustible dustsII 1D* 20 Zone 20 includes areas in which an explosive atmosphere caused

by a dust/air mixture arises constantly, long-term or frequently. Yes

II 2D 21 Zone 21 includes areas in which an explosive atmosphere is expected to arise occasionaly due to a dust/air mixture.

Yes

II 3D 22 Zone 22 includes areas in which an explosive atmosphere is not expected to arise from swirled up dust but if it does arise, it is likely to be rare and for a short period of time only.

No

*Not common for electric motors

Maintenance of explosion protection

Maintenance of explosion protection during operation:Electrical machine must be protected from overheating caused by overloads. The motor protection depends on both the operating mode and the use of the electrical machine.

Explosion-protected electric motors are generally approved for operating mode S1, i.e. continuous operation. Other operating modes are only permitted if the motor temperature is monitored by reliable devices.

Operating mode Motor protectionS1 Motor protection switch as per EN 60034-1; EN 60079-14

Motor protection switch and temperature sensor in the winding as additional protectionJust the temperature sensor in the winding as the main protection (only permitted for tested and approved motors and with approved control devices)

S2, S3 Motor protection switch with switch-on time switch and/or temperature sensor in the winding as additional protection.Just the temperature sensor in the winding as the main protection (only permitted for tested and approved motors and with approved control devices)

S4, S5, S6, S7, S8 Just the temperature sensor in the winding as the main protection (only permitted for tested and approved motors and with approved control devices)

S9, S10 Just the temperature sensor in the winding as the main protection (only permitted for tested and approved motors and with approved control devices)

Definition of operating modes as per EN 60034-1

1/6

Three-phase A.C. motors

HEW DEx series

Explosion-protected electric motors

Explosion-protected motors can be used in industrial plants in which explosive atmospheres which contain combustible vapours, gasses or dust (e.g. in the chemicals industry, oil refineries etc.) and in coal mines in which methane gasses are present.

These are three-phase AC asynchronous motors with squirrel cage which are pressure-tight as per standard EN 60079 (gas explosion protection) and DIN EN 50281 (dust explosion protection).

The housings of the motors are pressure-tight enclosures constructed as per EN 60079-1. The terminal boxes can also be constructed as "pressure-tight enclosures" as per EN 60079-1 or with "increased safety" as per EN 60079-7.

The following standards and regulations are adhered to when designing, manufacturing and testing electric motors.

Standard IEC International EN-CENELEC Europe

DINGermany

Rotating electrical machines - part 1: rating and performance IEC 60034-1 EN 60034-1 EN 60034-1

Degrees of protection provided by the integral design of rotating electrical machines (IP code) - classification

IEC 60034-5 EN 60034-5 EN 60034-5

Methods of cooling (IC code) IEC 60034-6 EN 60034-6 EN 60034-6

Classification of types of construction, mounting arrangements and terminal box position (IM code)

IEC 60034-7 EN 60034-7 EN 60034-7

Terminal markings and direction of rotation IEC 60034-8 EN 60034-8 EN 60034-8

Noise limits IEC 60034-9 EN 60034-9 EN 60034-9

Starting performance of single-speed three-phase cage induction motors

IEC 60034-12 EN 60034-12 EN 60034-12

Mechanical vibration of certain machines with shaft heights 56 mm and higher - measurement, evaluation and limits of vibration severity

IEC 60034-14 EN 60034-14 EN 60034-14

IEC standard voltages IEC 60038 IEC 60038

General purpose three-phase induction motors having standard dimen-sions and outputs

IEC 60072-1 * EN 50347 * EN 50347 *

Electrical apparatus for explosive gas atmospheres - part 0: general requirements

IEC 60079-0 EN 60079-0 EN 60079-0

Explosive atmospheres - part 1: equipment protection by flameproof enclosures "d"

IEC 60079-1 EN 60079-1 EN 60079-1

Explosive atmospheres - part 7: equipment protection by increased safety "e"

IEC 60079-7 EN 60079-7 EN 60079-7

Electrical apparatus for use in the presence of combustible dust IEC 61241-0IEC 61241-1

EN 61241-0EN 61241-1 (EN 50281)

EN 61241-0EN 61241-1 (EN 50281)

* Only applies to dimensions and construction sizes

1/7

1

Three-phase A.C. motors

HEW DEx series

Overview of EC type-examination certificates

Explosion protection II 2G EEx d IIC T4-T6, II 2G EEx de IIC T4-T6II 2D IP6X T135°C

Certificate Type DEx, DDEx Type DEx...G, Type DEx

63 71 80 90 100 112 132 160 180 200 225 250 280 315

PTB 07 ATEX 1058 X X

PTB 99 ATEX 1114 X X X X X

PTB 99 ATEX 11141. supplement X X

PTB 99 ATEX 1114 1)

2nd supplement X X X

PTB 99 ATEX 11143rd supplement X X X X X X X X X X

PTB 99 ATEX 1114 2)

4th supplement X X X X X X X

PTB 06 ATEX 1053 X X X

PTB 04 ATEX 1077 X

PTB 04 ATEX 1078 X

PTB 04 ATEX 1079 X

1) Construction with steel housing

2) Dust protection

1/8

Three-phase A.C. motors

HEW DEx series

Mechanical design

Construction typesSee the table for the type of construction and IM code (international mounting) of the most frequently used versions:

Type of construction Explanation Type of construction Explanation

IM B 3IM 1001

2 bearing shields with feet IM B5IM 3001

2 bearing shields without feetSecuring flange type A

IM V5IM 1011

2 bearing shields with feetShaft end bottomFastening on the wall

IM V1IM 3011

2 bearing shields without feetShaft end bottomSecuring flange type A

IM V6IM 1031

2 bearing shields with feetShaft end topFastening on the wall

IM V3IM 3031

2 bearing shields without feetShaft end topSecuring flange type A

IM B6IM 1051

2 bearing shields with feetConstruction type B3Fastening on the wallFeet left, viewed from drive side

IM B14IM 3601

2 bearing shields without feetSecuring flange type C

IM B7IM 1061

2 bearing shields with feetConstruction type IM B3Fastening on the wallFeet right, viewed from drive side

IM V18IM 3611

2 bearing shields without feetShaft end bottomSecuring flange type C

IM B8IM 1071

2 bearing shields with feetConstruction type IM B3Fastening on the ceiling

IM V19IM 3631

2 bearing shields without feetShaft end topSecuring flange type C

IM B15IM 1201

1 bearing shield with feetConstruction type B3 without bearing shield (also without rolling bearing) on drive sideInstallation on substructureAttached to front of housing on drive side

IM B9IM 9101

1 bearing shield without feetConstruction type IM B5 or IM B14without bearing shield (also with-out rolling bearing) on drive sideAttached to the front of housing on drive side

IM B35IM 2001

2 bearing shields with feetSecuring flange type A

IM V8IM 9111

1 bearing shield without feetShaft end bottomConstruction type IM V1 or IM V18without bearing shield (also with-out rolling bearing) on drive sideAttached to front of housing on drive side

IM B34IM 2101

2 bearing shieldswith feetSecuring flange type C

IM V9IM 9131

1 bearing shield without feetShaft end topConstruction type IM V3 or IM V19without bearing shield (also with-out rolling bearing) on drive sideAttached to the front of housingon drive side

1/9

1

Three-phase A.C. motors

HEW DEx series

Construction types

The construction types of electric motors and their symbols comply with the standards EN 60034-7. Our motors are available in basic construction types IM B3, IM B5 and IM B14.The table shows the symbols and the installation options of the standard models we manufacture. The type IM B3 motors can also be operated in the mounting positions IM B6, IM B7 and IM B8. As well as the flange sizes allocated in line with the standard, a number of other flange sizes can also be supplied (see page 1/11). On all construction types with the shaft end at the bottom the version "with safety cover" must be selected in order to prevent foreign bodies from falling in.

IP protection classes

The protection classes of circulating electric machines are denoted by an abbreviation in line with EN 60034-5. It consists of the letter IP (international protection) and two numbers.

1st number ( 0 to 6 ): Protection level for contact and foreign body protection.

2nd number ( 0 to 8 ): Protection level for water protection.

The motors are constructed with protection class IP 55. Motors can be supplied with a higher protection class on request.

Protection from solids and liquids: IP protection class

Protection class Protection from contact and the penetration of solid substances (first number)

IP 55 / IP 56 Full protection from contact with live and moving internal parts.Protection from penetration from dust.The penetration of dust is not completely prevented but cannot take on such a scale as to have a negative effect on operation of the machine.

IP 65* Complete protection from contact with live or moving internal parts.Penetration of dust is fully prevented.

Protection class Protection from penetration of water (second number)

IP 55 / IP65* The motor is protected from jets of water from all directions.

IP56 Machine protected from heavy seas. Water from heavy seas or a strong jet of water must not penetrate into the housing in damaging quantities.

* All vertically installed motors with an open shaft end at the top must be protected in such a way that no foreign objects can fall into the fan cover from above. However, this protection is not necessary if the machine is fitted with such a protective mechanism itself. Motors installed in the open must be protected from direct sunlight.

1/10

Three-phase A.C. motors

HEW DEx series

Housing design Standards for explosion protection taken into account when manufacturing and testing motors.

Standard IEC international Germany / Europe

Electrical equipment in explosive areasStandard version

Electrical equipment for operation in the explosive area Pressurised enclosure "d"

Electrical equipment for operation in the explosive areaIncreased safety "e"

IEC 60079-0

IEC 60079-1

IEC 60079-7

EN 60079-0

EN 60079-1

EN 60079-7

Construction

The electric motors are fully enclosed and have internal ventilation (with fan). The cooling effect is provided by external air directed through the outer, ribbed surface by the fan (cooling system IC 411 as per EN 60034-6 ). Motors of construction size up to 225 are produced with a grey cast iron housing. From construction size 250 upwards welded grey cast iron housings and terminal boxes are used.

Construction size Stator housing Bearing shields Terminal box

63Cast iron, screw-on feet,terminal box cast on the stator housing

Steel or cast ironB 5, B 14screw-on

Cast iron

71

80

Cast iron, screw-on feet

90

100

112

132

160

180

200

225

250

Welded steel plate, welded feet280

315

1/11

1

Three-phase A.C. motors

HEW DEx series

Flange variants

All motor types of construction size 63 to 225 have been engineered with screw-on flanges and/or feet for short delivery times. Thus all possible EN 60034-7 compliant construction types can be achieved based on the basic motor.

Available flanges

Construc-tion size

FF flanges Ø in mm (1) FT flanges Ø in mm (1)

115 130 165 215 265 300 350 400 500 600 75 85 100 115 130 165 215

A flanges Ø in mm (2) C flanges Ø in mm (2)

140 160 200 250 300 350 400 450 550 660 90 105 120 140 160 200 250

63 X O X O O

71 O X O X X O O O

80 O O X O X O O

90 O O X O O X O

100 O X O X O

112 O X O X O

132 O X X O

160 O X X

180 O X O

200 O O X

225 O X O

250 O X O

280 O X O

315 O X

X = allocation as per standard0 = special flange

Further flange variants available on request.

Note(1) new marking as per EN 50347(2) old marking as per DIN 42948

1/12

Three-phase A.C. motors

HEW DEx series

Bearings

The following table shows the bearings used on the various motors. On 4, 6 and 8 pole motors the bearings have a service life of 20 000 hours if the load values stipulated in the tables on pages 1/14 and 1/15 are not exceeded.

Only high-grade brand-name bearings are used. We also equip the motors (depending on the respective construction) with other types and sizes of bearing on request.

The standard version bearings for construction sizes 63 to 225 are on the D-side (drive side), and for construction sizes 250 to 315 they are on the N-side (non-drive side). The bearings are fixed bearings.

Bearing

Construction size Poles DS bearing NS bearing Sealing ring 63 2-8 6202 2Z C3 6202 2Z C3 12 x 32 x 771 2-8 6203 2Z C3 6203 2Z C3 17 x 40 x 780 2-8 6204 2Z C3 6204 2Z C3 20 x 47 x 790 2-8 6205 2Z C3 6205 2Z C3 25 x 52 x 7100 2-8 6206 2Z C3 6206 2Z C3 30 x 62 x 7112 2-8 6206 2Z C3 6206 2Z C3 30 x 62 x 7 132 2-8 6208 2Z C3 6208 2Z C3 40 x 80 x 10160 2-8 6309 2Z C3 6309 2Z C3 45 x 80 x 10180 2-8 6310 2Z C3 6310 2Z C3 50 x 72 x 10200 2-8 6312 2Z C3 6312 2Z C3 60 x 80 x 10225 2-8 6313 2Z C3 6313 2Z C3 65 x 90 x 10250 2-8 6314 2Z C3 6314 2Z C3 70 x 110 x 13280 2-8 6316 2Z C3 6316 2Z C3 80 x 105 x 13315 2-8 6317 2Z C3 6317 2Z C3 85 x 115 x 13

Motors with roller bearings up from size 160 upon requestMotors up from size 250 available with insulated bearings

Shaft ends

The shaft ends are cylindrical and their design complies with EN 50347. Allocation to construction sizes and outputs as per DIN 42673 part 3 and DIN 42677 part 3.On all motors the DS shaft end has a centering hole as per DIN 332 part 2 form D. The NS shaft end has a centering holes as per DIN 332 part 1. The keys are as per DIN 6885 part 1 and are always supplied with the motors. The design with a second free shaft end is available on request.

• up to a diameter of 50 mm – ISO k6• over 50 mm – ISO m6

Shaftdiameter

11 mm 14 mm 19 mm 24 mm 28 mm 38 mm From 42 to48 mm

From 55 to 80 mm

Inner thread M5 M5 M6 M8 M10 M12 M16 M20

Three-phase A.C. motors

1/13

Three-phase A.C. motors

HEW DEx series

Radial and axial forces

Permitted loads on free shaft end

1/14

Three-phase A.C. motors

HEW DEx series

Maximum radial load

Construction size Number of poles Radial force FR [kN]E0 E1 E2

63 2468

0.390.390.440.49

0.360.360.410.45

0.340.340.380.42

71 2468

0.480.600.690.76

0.430.540.620.68

0.390.500.560.62

80 2468

0.640.810.931.02

0.570.720.830.91

0.510.650.740.82

90 2468

0.720.901.041.14

0.640.800.921.01

0.570.710.820.90

100 2468

1.011.281.451.61

0.901.151.301.43

0.811.041.171.30

112 2468

0.991.231.421.57

0.871.091.251.39

0.791.081.121.24

132 2468

1.561.962.242.45

1.381.781.982.16

1.231.551.771.96

160 2468

2.993.834.334.79

2.633.383.814.22

2.353.023.403.78

180 2468

3.554.435.105.63

3.143.824.525.00

2.843.534.084.52

200 2468

4.334.456.286.88

4.244.955.716.25

3.604.525.235.72

225 2468

10.4013.1015.0316.60

9.4511.6513.3714.78

8.3210.4912.0313.39

250 2468

11.6414.7716.9718.73

10.4113.2215.2016.78

9.4011.9613.7515.19

280 2468

14.5218.1820.9322.93

13.0316.3118.7820.56

11.8014.7617.0218.62

315 2468

16.5520.6219.7321.93

14.9218.5717.5819.56

13.5716.8615.8217.62

1/15

Three-phase A.C. motors

Maximum axial load

Maximum load on free shaft end Fa [ kN]

Devicearrange-ment

IM B7 IM B8 IM B14 IM B34IM B3 IM B35 IM B5 IMJ B6

IM V18 IM V19 IM V 1 IM V3 IM V5 IM V6Weight of the rotor shaft in load direction

Weight of rotor shaft in opposite direction to load

2-pole

4-pole

6-pole

8-pole

2-pole

4-pole

6-pole

8-pole

2-pole

4-pole

6-pole

8-pole

63 0.26 0.26 0.31 0.34 0.27 0.27 0.32 0.35 0.13 0.13 0.15 0.17

71 0.27 0.34 0.39 0.43 0.33 0.43 0.47 0.52 0.35 0.46 0.51 0.55

80 0.36 0.45 0.52 0.57 0.43 0.55 0.62 0.69 0.47 0.60 0.69 0.76

90 0.41 0.51 0.59 0.65 0.48 0.61 0.69 0.77 0.54 0.68 0.79 0.86

100 0.55 0.69 0.79 0.88 0.64 0.81 0.92 1.03 0.75 0.94 1.07 1.11

112 0.55 0.69 0.79 0.88 0.63 0.77 0.89 1.00 0.76 0.98 1.10 1.14

132 0.83 1.04 1.20 1.32 0.92 1.13 1.30 1.48 1.16 1.47 1.67 1.82

160 1.52 1.91 2.19 2.41 1.65 2.10 2.40 2.65 2.13 2.68 3.08 3.31

180 1.77 2.24 2.56 2.82 1.85 2.30 2.71 3.00 2.55 3.26 3.74 4.13

200 2.23 2.94 3.37 3.71 2.39 3.06 3.54 3.89 3.45 4.38 4.91 5.50

225 2.66 3.36 3.85 4.23 2.71 3.30 3.78 4.25 4.03 5.05 5.94 6.28

250 2.98 3.76 4.30 4.73 2.92 3.85 4.07 4.48 4.62 5.55 6.81 7.46

280 3.50 4.41 5.05 5.56 3.18 3.76 4.52 4.82 5.51 7.13 7.94 8.89

315 3.58 4.51 5.17 5.69 2.33 2.31 2.01 2.55 6.09 8.15 9.34 10.05

The nominal load for the bearings is calculated for a service life of at least 20 000 hours at a frequency of 50 Hz. Only axial loads are taken into consideration. In case of combined axial and radial load the service life of the bearings is shorter.

HEW DEx series

Three-phase A.C. motors

1/16

Three-phase A.C. motors

HEW DEx series

Bearing lubrication

The standard version motors are fitted with permanently lubricated bearings. Any deviation from the nominal operating temperature for the motors has an influence on the service life of the bearings.(In case of extreme conditions for use, adhere to the recommendations of the manufacturer)

Motors with lubricating equipment

Motors from construction size 160 and above can be fitted with lubricating equipment. The lubrication intervals for these motors have to be adhered to and the named types of grease must be used. After lubricating, the bearing should be run without a load to distribute the grease.

The effectiveness of the bearing lubrication should be checked by measuring the temperature on the bearing shield with the motor running. If the measured temperature exceeds +80 degrees C, the lubricating intervals have to be shortened. Lubrication intervals should be halved for every 15 K in the temperature increase. If this is not possible, special lubricants for very high temperatures should be used.

Lubricating ball bearings - intervals in operating hours

Construction size

Grease quantity

[g]

Speed [min-1]3600 3000 1800 1500 1000 500

160 25 7000 9500 14000 17000 21000 24000180 30 6000 8000 13500 16000 20000 23000200 40 4000 6000 11000 13000 17000 21000225 50 3000 5000 10000 12500 16500 20000250 60 2500 4000 9000 11500 15000 18000280 70 2000 3500 8000 10500 14000 17000315 90 2000 3500 6500 8500 12500 16000

Lubricating roller bearings - intervals in operating hours

Construction size

Grease quantity

[g]

Speed [min-1]3600 3000 1800 1500 1000 500

315 45 1000 1700 3000 4300 6000 8000

1/17

1

Three-phase A.C. motors

HEW DEx series

Position of terminal box and cable entries

Positions of the terminal box and the cable entries in the terminal box are available as per the following table:

Construc-tion size

Version Standardversion

Specialversion

Version Standardversion

Specialversion

63 Foot 270°B - Flange 0°B -

71 Foot 270°B - Flange 0°B -

80 Foot 270°R 270° A. B. L Flange 0° R 0° A, B, L / 90° A, B, R, L180° A, B, R, L / 270° A, B, R, L

90 Foot 270°R 270° A, B, L Flange 0° R 0° A, B, L / 90° A, B, R, L180° A, B, R, L / 270° A, B, R, L

100 Foot 270°R 270° A, B, L Flange 0° R 0° A, B, L / 90° A, B, R, L180° A, B, R, L / 270° A, B, R, L

112 Foot 270°R 270° A, B, L Flange 0° R 0° A, B, L / 90° A, B, R, L180° A, B, R, L / 270° A, B, R, L

132 Foot 270°R 270° A, B, L Flange 0° R 0° A, B, L / 90° A, B, R, L180° A, B, R, L / 270° A, B, R, L

160 Foot 270°R 270° A, B, L Flange 0° R 0° A, B, L / 90° A, B, R, L180° A, B, R, L / 270° A, B, R, L

180 Foot 270°R 270° A, B, L Flange 0° R 0° A, B, L / 90° A, B, R, L180° A, B, R, L / 270° A, B, R, L

200 Foot 270°R 270° A, B, L Flange 0° R 0° A, B, L / 90° A, B, R, L180° A, B, R, L / 270° A, B, R, L

225 Foot 270°R 270° A, B, L Flange 0° R 0° A, B, L / 90° A, B, R, L180° A, B, R, L / 270° A, B, R, L

250 Foot 270°R 0° A, B, R, L180° A, B, R, L270° A, B, L

Flange 0° R 0° A, B, L / 90° A, B, R, L180° A, B, R, L / 270° A, B, R, L

280 Foot 270°R 0° A, B, R, L180° A, B, R, L270° A, B, L

Flange 0° R 0° A, B, L / 90° A, B, R, L180° A, B, R, L / 270° A, B, R, L

315 Foot 270°R 0° A, B, R, L180° A, B, R, L270° A, B, L

Flange 0° R 0° A, B, L / 90° A, B, R, L180° A, B, R, L / 270° A, B, R, L

Normal terminal box position 0° R

Viewed looking at the shaft mirror

To determine the position of the terminal box

1/18

Three-phase A.C. motors

HEW DEx series

Type EEx e terminal boxes are fitted with threaded holes (as per table) and the corresponding EEx e screwed cable glands.

Type EEx d terminal boxes are supplied with threaded holes (as per table) as standard. The screwed cable glands are not included in the scope of delivery (other threads on request).

Terminal boxes and cable entries

Construction size

TerminalsFor connection cables with a

max. cross section (mm2)

Cable entries for power cablesEEx e housing EEx d housing

Threaded hole Outer diameter of connection cable (mm)

Threaded hole

63 2.5 2 x M20 x 1.5 6.5 to 12 2 x M20 x 1.5

71 2.5 2 x M20 x 1.5 6.5 to 12 2 x M20 x 1.5

8090100

4 1 x M25 x 1.51 x M20 x 1.5

13 to 186.5 to 12

1 x M25 x 1.51 x M20 x 1.5

112 4 1 x M32 x 1.51 x M20 x 1.5

13 to 186.5 to 12

1 x M32 x 1.51 x M20 x 1.5

132 4 2 x M32 x 1.51 x M20 x 1.5

13 to 186.5 to 12

2 x M32 x 1.51 x M20 x 1.5

160180

16 2 x M40 x 1.51 x M20 x 1.5

22 to 326.5 to 12

2 x M40 x 1.51 x M20 x 1.5

200225

16 2 x M50 x 1.51 x M20 x 1.5

32 to 386.5 to 12

2 x M50 x 1.51 x M20 x 1.5

250280315

95-300 2 x M63 x 1.51 x M20 x 1.5

37 to 446.5 to 12

2 x M63 x 1.51 x M20 x 1.5

Additional drilled holes for screwed cable glands (as per Directive 94/EU) can be supplied on request.

On special versions (e.g. anti-condensation heating) the motors are fitted with an additional cable entry M20 x 1.5.

1/19

1

Three-phase A.C. motors

HEW DEx series

Noise and vibration

Noise level

The noise level is below the permitted values for motors with external fan cooling as stipulated in EN 60034-9.

Maximum permitted noise level L in dB (distance of one metre from the motor surface) Values for surface-cooled motors with protection class IP 55

Nominal outputP [ kW ]

Speed [min-1]

600 < n < 960 960< n <1320 1320< n <1900 1900< n <2360 2360< n <3150 3150< n <3750

P < 1.1

1.1 < P < 2.2

2.1 < P < 5.5

5.5 < P < 11

11 < P < 22

22 < P < 37

37 < P < 55

55 < P < 110

110 < P < 220

67

69

72

75

78

80

81

84

87

70

70

74

78

82

84

86

89

91

71

73

77

81

85

86

88

92

94

74

78

82

86

87

89

92

93

96

75

80

83

87

91

92

94

96

98

79

82

85

90

93

95

97

98

100

Vibrations

The motors' rotors are dynamically balanced with fan fitted and half a key. The vibration amplitude is equivalent to level N (normal) as per EN 60034-14 ( ISO 2373 level N ).

Vibration limit valuesFor electrical machines (EN 60034-14; ISO 2373)

Level Speed [min-1] Vibration limit values [ mm/s ]80 to 132 160 to 225 30 to 225

N(normal)

600 to 18001 800 to 3600

1.80 2.80 4.50

R(reduced)

600 to 1,8001800 to 3600

0.711.12

1.121.80

1.802.80

S(special)

600 to 1,8001800 to 3600

0.450.71

0.711.12

1.121.80

The vibration level is the highest effective value of the vibration speed in the frequency range 10 Hz to 1 000Hz.

1/20

Three-phase A.C. motors

HEW DEx series

Power, voltage and frequency

The data in the technical tables relate to continuous operation (S1 as per EN 60034-1) of the motors at rated voltage, rated frequency, coolant temperature up to + 40°C and an installed height of < 1000 m above sea level.

Voltage fluctuations of up to ± 5 % and frequency fluctuations of up to ± 2% are permitted. Within this tolerance range the power data remains unchanged and the maximum permitted temperature of the winding is not exceeded.

On request motors for rated voltages from 110V to 690V and rated frequencies from 50Hz to 60Hz can be supplied. The motors de-signed for voltages of 380V, 400V and 415V and a frequency of 50Hz can also be operated in the range of 440V and 480V at a frequency of 60 Hz. The load can be increased to 15%. The speed is around 20% higher whilst the starting torque and maximum torque are around 18% lower.

Pay attention to the following when selecting the ideal motor output:Required output of the working machine; operation mode; starting, braking and reversing operation, progression of torque of the work-ing machine; power supply conditions (FC operation); cooling, coolant temperature; installed height.

Heating and thermal classes

The selection of individual components for the insulation system is determined by the allocation into thermal classes as per EN 60034-1.

The motor's stator windings are designed as per thermal class F. The stator windings are manufactured with phase insulation of high-grade enamelled wire and resin varnish for impregnating. The high electrical strength which this achieves ensures that the motors can be used problem-free with the frequency converter.

On request motors can also be supplied for use in extreme operating conditions or high switching frequency with a winding for thermal class H.

Connections

The winding on motors with a nominal output of up to 2.2kW are designed for a 400V star connection. Motors with a higher output are designed for a 400V delta connection (star delta start-up) Pole-changing motors with a speed ration of 2:1 are designed with Dahlader pole changing connection (separate winding available on request). Other pole rations are realised with two separate windings in a star connection.

Overload

The motors are designed so that they can be overloaed 1.5 times for two minutes once operating temperature has been reached without damage being caused.

Instructions for installation

Mains connection and commissioning of motors with EEx e terminal box.The motors are supplied with approved screwed cable glands as standard. Mains connection and commissioning of motors with EEx d terminal box.The motors have to be connected using suitable cables and cable entries as per EN 60079-1. Unused openings must be sealed as per EN 60079-1. Cables, screwed cable glands and sealing plugs which do not meet with these requirements must not be used.

Rotation

The motors can generally be used for both rotation directions. The winding ends U1, V1, W1 of the motors are designed so that the order L1, L2, L3 results in clockwise rotation when connected to the three-phase mains. Swapping two outer conductors (e.g. L1 with L2) results in anti-clockwise rotation. The rotation direction is stated as looking at the shaft mirror (DS).

Earthing and protective ground

The motors have protective ground connection in the terminal box and an additional external ground terminal on the motor housing.

Electrical design

1/21

1

Three-phase A.C. motors

HEW DEx series

Operation on the inverter

The use of an inverter makes it possible to set and adjust the speed of asynchronous three-phase AC motors continuously variably. Careful planning is key to ideally adapting the converter and motor. The pressurised HEW motors can be used in a frequency range of 5 Hz to 87 Hz. The PTC-resistor, which is installed as standard has to be used as the only form of motor protection.

The choice of motor is based primarily on the desired speed range and the progression of the characteristic curve of torque of the working machine. The most critical operating point has to be determined during planning and the motor construction size and number of poles selected accordingly. The most critical operating point is often at the lowest frequency as the reduced cooling of the internally ventilated motor means torque has to be reduced compared to nominal torque. However, it can also be in field weakening mode if the motor is used for this mode.

If the voltage on the inverter is increased proportionally with the frequency, the flow remains constant and the motor can be operated with constant torque (taking into account the reduction in torque due to the reduced cooling at low frequencies). If the voltage remains constant and only the frequency increases, this is referred to as field weakening mode and the motor torque is reduced at 1/f.

The numerous influential components at inverter operation makes it clear that careful planning is not only necessary for perfect opera-tion, but also for the best possible solution from the point of view of cost.

The tables of pages 4/4 and 4/4 show the permitted torque values for the typical speed ranges for 2, 4, 6 and 8-pole motors.

Our technical department is available to answer any questions.

Basic representation

1 U/f constant to 50 Hz Output increases proportionally with speedMotor torque constant(Torque reduction as per tables / page 4/1 to 4/4)

2 U/f constant from 50 Hz to 87 Hz Output increases proportionally with speedMotor torque constant

3 U constant from 50 Hz to 87 Hz Output remains constantMotor torque drops at 50/f

1/22

Three-phase A.C. motors

HEW DEx series

Motor protection

The motor protection must be provided in line with EN 60079-14. The motors must be protected with a motor protection switch or equivalent equipment on all poles to prevent inadmissible heating due to overload. A PTC-resistor for winding temperature monitoring in conjunction with a triggering device is regarded as equivalent protective equipment. Motors up to 200 kW can be fitted with such as the only form of protection. Using temperature monitoring as the only form of protection is stipulated for all operating modes which deviate from S1 operation, such as operation with frequency converter, switching operation, short-tem operation, heavy starting etc. Protection is also provided in case of reduced cooling air flow and/or too high ambient temperature. The pressure-tight HEW motors are fitted with PTC-resistor as standard. The motors can be equipped with other optional temperature sensors, e.g. early warning.

Cooling (ventilation)

All motors are fitted with a robust and temperature-resistant plastic or aluminium fan.

External ventilation (IC 416):

External fans are used, for instance, to increase the nominal output, for high switching frequencies and, if necessary, when operating with a frequency converter. All external fans are supplied with a three-phase connection.

Stationary motor heating

Anti-condensation heaterThe motors are fitted with an anti-condensation heater to prevent heavy condensation on the stator winding in case of major temperature fluctuations and load changes, e.g. when periodically at a standstill.

Anti-freezing heaterA stationary motor heater is a stipulated requirement for ambient temperatures < -20°C.

The stationary motor heater must not be switched on whilst the motor is in operation.

Anti-condensation heater Anti-freezing heater

Motorconstruction size

Heating power

[W]

Supplyvoltage*

[V]

Motorconstruction size

Heating power

[W]

Supplyvoltage*

[V]63 12,5 230 ± 10% 63 12,5 230 ± 10%

71 12,5 230 ± 10% 71 12,5 230 ± 10%

80 25 230 ± 10% 80 25 230 ± 10%

90 25 230 ± 10% 90 25 230 ± 10%

100 25 230 ± 10% 100 50 230 ± 10%

112 50 230 ± 10% 112 50 230 ± 10%

132 50 230 ± 10% 132 50 230 ± 10%

160 50 230 ± 10% 160 75 230 ± 10%

180 75 230 ± 10% 180 150 230 ± 10%

200 75 230 ± 10% 200 200 230 ± 10%

225 100 230 ± 10% 225 200 230 ± 10%

250 150 230 ± 10% 250 300 230 ± 10%

280 200 230 ± 10% 280 300 230 ± 10%

315 250 230 ± 10% 315 400 230 ± 10%

*Special voltages on request

1/23

1

Three-phase A.C. motors

HEW DEx series

Motors with brake

The motors can be fitted with an optional separate mechanical brake. The brakes are equipped with their own terminal box. The winding of the motor is not subject to thermal strain by the braking procedure. The braking motors are used for lifting and travelling drives, tool machines, packaging machines, conveying technology, servo drives etc.

Allocation of motor construction size / braking torque (reduced braking torque on request)

Braking torque[Nm]

63 71 80 90 100 112 132 160 180 200 225

8 224060150180335460500

Voltages:

The brakes are available with connection voltages 400V ~, 230V~ and 24V. Other special voltages are available on request.

Version:

The brakes comply with ignition protection type II 2GD EEx d IIC T5 and thus approved for use in zone 1 and zone 2, and zone 21 and zone 22. The brakes can be used as standard for a temperature range of –20°C to +55°C. (special version for –50°C to +55°C available). The brakes are fitted with a thermal switch for temperature monitoring.

Special versions:- Brakes with manual release The brake can be supplied with optional manual release. Pulling the manual release lever when disconnected from the power releases the brake mechanically and the shaft cannot rotate - Brakes with stationary motor heater- Temperature monitoring with PTC-resistor instead of thermal switch - Brake motors with second shaft end - Brake motors with additional balancing weight The additional balancing weight is used for starting up and braking without jerking and is installed under the ventilation hood. - Braking motors with external fan and/or hollow shaft encoder

Motors with an encoder

Motors can be equipped with an optional hollow shaft encoder with the following technical data:

Standard version Special versionManufacturer: Kübler KüblerConnection: 3 m cable without plug Other cable lengths with/without plugPulses/revolution: 1024 10 – 5000Output signal lever: TTL or HTL On requestSupply voltage: 5V or 10-30V -Ignition protection type: II 2G EEx d IIC T6 -

Dimensioned drawings: See page 6.1 (braking motors) and 6.3 (motors with encoder)

Customized Motors

1/24

Three-phase A.C. motors

HEW DEx series

The motors can optionally be supplied in the following special versions:

Assy. 63 71 80 90 100 112 132 160 180 200 225 250 280 315Unusual voltage ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Unusual frequency ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Special shaft ● ● ● ● ● ● ● ● ● ● ● ● ● ●

2nd shaft end ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Special flange ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Concentricity R ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Drive side fixed bearing ● ● ● ● ● ●

Oil-tight ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Protection class IP56 ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Protection class IP65 ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Protection class IP66 ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Safety cover ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Vibration severity level R

● ● ● ● ● ● ● ● ● ● ● ● ● ●

Vibration severity level S

● ● ● ● ● ● ● ● ● ● ● ● ● ●

Tropical insulation ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Anti-condensation heater

● ● ● ● ● ● ● ● ● ● ● ● ● ●

Stationary motor heater to prevent low tempera-tures (< -20°)

● ● ● ● ● ● ● ● ● ● ● ● ● ●

Roller bearings ● ● ● ● ● ● ●

Insulated bearings ● ● ●

Lubrication equipment ● ● ● ● ● ● ●

Motors with a brake ● ● ● ● ● ● ● ● ● ● ●

Motors with external fan

● ● ● ● ● ● ● ● ● ● ● ●

Motors with an encoder ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Motors with motor cable

● ● ● ● ● ● ● ● ● ● ●

Temperature class T5 ● ● ● ● ● ● ● ● ● ● ● ● ●

Temperature class T6 ● ● ● ● ● ● ● ● ● ● ● ●

Approval 2D / Zone 21 ● ● ● ● ● ● ●

VIK version ● ● ● ● ● ● ● ● ● ● ● ● ● ●

GL approval ● ● ● ● ● ● ● ● ● ● ● ● ●

Gost-R approval ● ● ● ● ● ● ● ● ● ● ● ● ●

Special lacquer ● ● ● ● ● ● ● ● ● ● ● ● ● ●

● Available as an option on request.

Customized Motors

Explosion-protectedthree-phase A.C. motors

( single-speed )

2/1

263K/2 0.18 2750 64.5 0.77 0.52 0.62 3.9 3.0 2.9 0.00014 13

63L/2 0.25 2765 67.0 0.80 0.67 0.86 4.2 2.7 2.7 0.00019 14

71K/2 0.37 2820 67.2 0.81 0.98 1.25 5.4 3.0 3.2 0.00034 15

71L/2 0.55 2800 72.7 0.86 1.28 1.9 5.4 2.8 3.1 0.00042 16

80K/2 0.75 2810 77.5 0.87 1.61 2.5 4.9 2.6 2.8 0.00063 24

80L/2 1.1 2775 78.8 0.88 2.29 3.8 5.1 2.8 2.9 0.00079 26

90S/2 1.5 2855 81.6 0.86 3.07 5.0 6.1 2.8 3.1 0.00124 32

90L/2 2.2 2845 80.8 0.89 4.4 7.4 5.9 2.7 2.7 0.00155 34

100L/2 3.0 2875 79.5 0.85 6.4 10 5.7 3.0 3.3 0.0025 43

112M/2 4.0 2880 84.0 0.88 7.8 13.3 6.9 2.7 3.1 0.0045 58

132S/2 5.5 2910 87.0 0.88 10.4 18 6.3 2.6 3.0 0.0097 77

132S/20 7.5 2920 87.7 0.88 14.1 25 6.9 3.0 3.3 0.0122 84

160M/2 11 2940 89.4 0.86 20.6 36 7.9 3.8 3.3 0.0294 148

160M/20 15 2940 90.6 0.90 26.5 49 7.9 3.4 3.0 0.0391 166

160L/2 18.5 2945 91.6 0.91 32.2 60 7.4 3.1 3.1 0.0459 178

180M/2 22 2940 84.2 0.91 41.3 71 6.9 2.8 2.9 0.0615 205

200L/2 30 2955 88.5 0.90 54.4 97 6.9 2.4 2.6 0.1044 240

200L/20 37 2970 88.6 0.91 66.5 119 9.0 3.3 3.0 0.1274 250

225M/2 45 2970 89.6 0.88 82.0 145 7.6 2.5 3.1 0.2216 375

250M/2 55 2970 89.3 0.91 98.0 177 6.6 2.1 2.2 0.675 485

280S/2 75 2980 90.8 0.88 136 241 8.25 3.0 2.7 0.95 650

280M/2 90 2980 91.5 0.90 158 289 8.1 3.0 2.6 1.1 700

315S/2 110 2970 91.5 0.94 186 353 7.2 2.5 3.1 1.55 820

315M/2 132 2985 92.1 0.93 223 425 7.5 2.8 2.8 1.8 930

315M/20 160 2975 90.1 0.94 272 515 8.1 2.9 3.1 2.2 1240

315L/2 200 2980 93.0 0.90 245 640 6.9 2.3 2.6 2.8 1380

Three-phase A.C. motors

HEW DEx series

TypeConstruc-tion size

DExorDDEx

Nominaloutput

PN

kW

Nominalspeed

nN

min-1

Efficiency

h

%

Powerfactor

cos j

Nominalcurrent(400V)

IN

A

Nominaltorque

MN

Nm

Starting to

nominal current

IA / IN

Starting to

nominaltorque

MA / MN

Break-down to nominaltorque

MK / MN

Momentof

torque

JM

kgm²

Weight

approx. kg

No. of poles: 2 Nominal data at 400V, 50Hz Thermal class F

Operating mode: S1 Synchronous speed: 3,000min-1 Surface cooling IC411

2/2

63K/4 0.12 1345 59.0 0.69 0.42 0.85 2.8 2.2 2.3 0.00021 13

63L/4 0.18 1370 65.0 0.65 0.61 1.25 3.2 2.5 2.6 0.00029 14

71K/4 0.25 1370 67.0 0.78 0.69 1.74 3.8 2.15 2.2 0.00051 15

71L/4 0.37 1385 72.5 0.78 0.95 2.55 4.0 2.15 2.3 0.00063 16

80K/4 0.55 1400 76.9 0.77 1.34 3.76 4.4 2.3 2.4 0.00098 24

80L/4 0.75 1410 82.4 0.77 1.7 5.1 5.0 2.6 2.7 0.00125 26

90S/4 1.1 1410 80.9 0.82 2.4 7.5 4.8 2.15 2.5 0.00204 32

90L/4 1.5 1415 80.6 0.8 3.35 10.1 5.2 2.5 2.8 0.0026 35

100L/4 2.2 1410 81.5 0.82 4.7 14.9 4.6 2.0 2.5 0.00388 43

100L/40 3.0 1415 79.6 0.83 6.5 20.2 5.0 2.1 2.6 0.00499 46

112M/4 4.0 1435 85.4 0.81 8.3 26.6 6.1 2.8 3.1 0.01014 60

132S/4 5.5 1435 86.0 0.85 10.8 36.6 5.1 2.2 2.4 0.02113 84

132M/4 7.5 1445 88.9 0.84 14.5 49.5 6.0 2.5 2.8 0.02793 93.5

160M/4 11.0 1460 87.1 0.83 22.0 71.8 6.9 2.9 3.1 0.05417 159

160L/4 15.0 1465 90.8 0.83 29.0 97.8 7.4 3.1 3.0 0.07116 178

180M/4 18.5 1465 89.9 0.86 35.0 121 6.9 3.1 2.5 0.1129 215

180L/4 22.0 1470 90.9 0.86 40.5 143 7.1 3.1 2.6 0.1339 236

200L/4 30.0 1470 89.6 0.91 53.4 195 6.8 2.7 2.8 0.21298 250

225S/4 37.0 1475 92.2 0.87 66.6 240 7.0 2.9 2.4 0.36225 310

225M/4 45.0 1475 92.5 0.87 80.5 291 7.3 3.3 2.7 0.42845 390

250M/4 55.0 1480 92.5 0.89 98.0 355 7.7 3.4 2.7 0.875 480

280S/4 75.0 1485 92.2 0.84 138 482 7.6 3.0 2.4 1.875 610

280M/4 90.0 1490 93.5 0.84 166 578 7.8 2.8 2.6 2.25 685

315S/4 110 1485 90.7 0.84 207 706 6.3 2.6 2.5 3.5 820

315M/4 132 1485 92.2 0.88 235 851 6.9 3.0 2.5 3.875 930

315M/40 160 1490 92.5 0.84 298 1027 5.8 1.9 2.1 5.0 1240

315L/4 200 1485 93.0 0.88 352 1285 6.8 1.5 1.6 6.1 1380

Three-phase A.C. motors

HEW DEx series

No. of poles: 4 Nominal data at 400V, 50Hz Thermal class F

Operating mode: S1 Synchronous speed: 1,500min-1 Surface cooling IC411

TypeConstruc-tion size

DExorDDEx

Nominaloutput

PN

kW

Nominalspeed

nN

min-1

Efficiency

h

%

Powerfactor

cos j

Nominalcurrent(400V)

IN

A

Nominaltorque

MN

Nm

Starting to

nominal current

IA / IN

Starting to

nominaltorque

MA / MN

Break-down to nominaltorque

MK / MN

Momentof

torque

JM

kgm²

Weight

approx. kg

2/3

63K/6 0.09 895 51.0 0.61 0.42 0.96 2.3 2.2 2.3 0.00031 13

63L/6 0.12 900 55.0 0.60 0.52 1.27 2.5 2.5 2.5 0.00042 14

71K/6 0.18 930 60.0 0.65 0.67 1.86 3.1 2.1 2.3 0.00081 15

71L/6 0.25 940 64.0 0.67 0.85 2.56 3.7 2.2 2.5 0.00101 16

80K/6 0.37 925 67.0 0.72 1.1 3.83 3.6 2.3 2.5 0.00191 25

80L/6 0.55 915 72.0 0.74 1.5 5.7 4.1 2.35 2.5 0.00239 27

90S/6 0.75 915 70.0 0.74 2.1 7.8 3.7 1.8 2.1 0.00323 32

90L/6 1.1 915 73.0 0.73 3.0 11.5 4.1 2.1 2.3 0.00419 35

100L/6 1.5 930 76.0 0.77 3.7 15.4 4.7 2.2 2.3 0.00657 46

112M/6 2.2 960 82.0 0.78 5.0 21.9 6.1 2.6 2.7 0.0158 60

132S/6 3.0 975 83.5 0.79 6.6 29.4 6.3 2.3 2.5 0.02722 84

132M/6 4.0 960 83.0 0.8 8.8 39.9 6.3 2.4 2.9 0.03229 88

132M/60 5.5 955 83.5 0.81 11.8 55.1 6.1 2.3 2.9 0.03838 95

160M/6 7.5 970 86.0 0.8 15.8 74.2 6.7 2.7 2.4 0.08121 161

160L/6 11.0 965 88.5 0.77 23.5 109 6.0 2.2 2.3 0.10916 182

180L/6 15.0 965 89.5 0.78 31.0 148 5.2 1.9 2.3 0.227 236

200L/6 18.5 965 91.0 0.81 36.0 183 6.0 1.9 2.4 0.24369 240

200L/60 22.0 965 91.5 0.81 43.0 219 6.0 1.9 2.4 0.27888 250

225M/6 30.0 975 92.5 0.83 56.0 293 5.8 1.8 2.5 0.66117 390

250M/6 37.0 985 93.5 0.83 69.0 359 6.0 2.8 2.6 1.125 480

280S/6 45.0 985 94.5 0.84 82.0 437 6.3 2.5 2.7 2.3 610

280M/6 55.0 985 94.5 0.84 101 534 6.0 2.4 2.8 2.625 685

315S/6 75.0 980 95.0 0.82 140 732 5.9 2.5 2.8 4.625 820

315M/6 90.0 985 95.5 0.84 163 874 5.1 2.1 2.9 5.25 930

315M/60 110 990 91.5 0.88 198 1060 6.5 2.5 2.4 6.0 1240

315L/6 132 990 90.5 0.88 238 1275 6.8 2.6 2.4 7.3 1380

2

Three-phase A.C. motors

HEW DEx series

No. of poles: 6 Nominal data at 400V, 50Hz Thermal class F

Operating mode: S1 Synchronous speed: 1,000min-1 Surface cooling IC411

TypeConstruc-tion size

DExorDDEx

Nominaloutput

PN

kW

Nominalspeed

nN

min-1

Efficiency

h

%

Powerfactor

cos j

Nominalcurrent(400V)

IN

A

Nominaltorque

MN

Nm

Starting to

nominal current

IA / IN

Starting to

nominaltorque

MA / MN

Break-down to nominaltorque

MK / MN

Momentof

torque

JM

kgm²

Weight

approx. kg

2/4

63L/8 0.06 600 31.0 0.73 0.39 0.80 1.7 1.4 1.4 0.0002 14

71K/8 0.09 680 38.0 0.51 0.67 1.26 2.0 2.0 2.1 0.00081 15

71L/8 0.12 655 45.0 0.71 0.54 1.75 2.4 1.8 2.1 0.00101 16

80K/8 0.18 680 61.0 0.65 0.66 2.53 2.9 2.1 2.2 0.00191 25

80L/8 0.25 680 58.0 0.68 0.92 3.52 3.1 2.1 2.3 0.00239 27

90S/8 0.37 685 66.0 0.65 1.25 5.2 3.0 1.7 2.0 0.00323 32

90L/8 0.55 685 69.0 0.66 1.75 7.7 3.1 1.75 2.1 0.00419 35

100L/8 0.75 690 69.0 0.69 2.3 10.4 3.5 1.8 2.1 0.00657 43

100L/80 1.1 695 70.0 0.7 3.25 15.0 3.8 1.9 2.2 0.00857 46

112M/8 1.5 710 78.0 0.67 4.15 20.2 4.3 2.0 2.5 0.0158 60

132S/8 2.2 710 79.0 0.74 5.5 29.6 4.3 1.9 2.2 0.02606 79

132M/80 3.0 710 80.0 0.76 7.2 40.4 4.8 2.1 2.3 0.03446 85

160M/8 4.0 720 82.6 0.71 10.0 53.1 4.8 1.8 2.3 0.0688 146

160M/80 5.5 715 84.0 0.71 13.4 73.6 4.8 1.8 2.1 0.08939 160

160L/8 7.5 725 86.5 0.75 16.7 98.8 5.8 2.3 2.1 0.12027 182

180L/8 11.0 715 86.7 0.74 25.0 147 4.2 1.8 2.5 0.227 236

200L/8 15.0 720 91.0 0.82 29.0 196 4.5 2.1 2.5 0.37827 250

225S/8 18.5 710 91.0 0.79 37.0 249 4.6 2.1 2.6 0.57008 310

225M/8 22.0 715 91.5 0.77 45.0 294 4.6 2.1 2.6 0.67806 390

250M/8 30.0 730 92.8 0.79 59.0 398 5.4 1.7 2.4 1.175 480

280S/8 37.0 730 93.0 0.78 74.0 485 6.0 1.9 2.3 2.3 610

280M/8 45.0 735 93.5 0.78 90.0 586 6.4 1.9 2.7 2.625 685

315S/8 55.0 735 94.5 0.81 104 716 6.2 2.2 2.3 4.625 820

315M/8 75.0 740 94.5 0.82 140 969 6.3 1.8 2.1 5.25 930

315M/80 90.0 740 91.1 0.83 173 1160 6.7 2.5 2.5 6.0 1240

315L/8 110 740 90.0 0.83 213 1420 6.9 2.6 2.5 7.3 1380

Three-phase A.C. motors

HEW DEx series

No. of poles: 8 Nominal data at 400V, 50Hz Thermal class F

Operating mode: S1 Synchronous speed: 750min-1 Surface cooling IC411

TypeConstruc-tion size

DExorDDEx

Nominaloutput

PN

kW

Nominalspeed

nN

min-1

Efficiency

h

%

Powerfactor

cos j

Nominalcurrent(400V)

IN

A

Nominaltorque

MN

Nm

Starting to

nominal current

IA / IN

Starting to

nominaltorque

MA / MN

Break-down to nominaltorque

MK / MN

Momentof

torque

JM

kgm²

Weight

approx. kg

Explosion-protectedthree-phase A.C. motors

(pole-changing)

63K/4-2 0.09 1380 0.45 0.62 3.2 2.2 0.0002 13

0.12 2800 0.50 0.41 3.5 2.1

63L/4-2 0.12 1390 0.50 0.82 3.6 2.2 0.0003 14

0.18 2800 0.55 0.61 3.8 2.0

71K/4-2 0.21 1380 0.75 1.45 3.6 2.1 0.0005 16

0.28 2800 0.90 0.96 3.9 2.1

71L/4-2 0.30 1380 1.05 2.08 3.8 2.1 0.0006 17

0.43 2800 1.25 1.47 4.0 2.0

80K/4-2 0.50 1370 1.26 3.49 3.7 1.8 0.0010 25

0.65 2760 1.43 2.25 3.4 1.9

80L/4-2 0.70 1365 1.75 4.90 4.1 2.0 0.0013 28

0.85 2810 1.85 2.89 5.5 2.4

90S/4-2 1.1 1415 2.60 7.42 4.4 1.9 0.0020 34

1.4 2800 2.95 4.78 4.7 2.0

90L/4-2 1.5 1410 3.30 10.2 4.9 2.1 0.0026 36

1.9 2850 3.90 6.37 5.3 2.3

100L/4-2 1.8 1430 4.16 12.0 4.8 2.0 0.0039 45

2.4 2860 5.25 8.01 5.0 1.9

100L/4-20 2.6 1420 5.65 17.5 5.8 2.1 0.0050 49

3.2 2870 6.60 10.7 6.6 2.3

112M/4-2 3.7 1460 8.40 24.2 6.6 2.8 0.0101 64

4.4 2890 8.50 14.5 7.4 2.9

132S/4-2 5.0 1460 11.5 32.7 6.2 2.7 0.0211 89

6.0 2900 11.9 19.8 6.4 2.8

132M/4-2 6.1 1450 13.8 40.2 6.7 2.5 0.0279 99

7.5 2910 15.4 24.6 6.9 2.3

3/1

No. of poles: 4-2 Nominal data at 400V, 50Hz s / YY Thermal class F

Operating mode: S1 Synchronous speed: 1500-3000min-1 Surface cooling IC411

TypeConstruc-tion size

DExorDDEx

Nominaloutput

PN

kW

Nominalspeed

nN

min-1

Nominalcurrent(400V)

IN

A

Nominaltorque

MN

Nm

Starting to nominal

current

IA / IN

Breakdownto nominal

torque

MK / MN

Momentof

torque

JM

kgm²

Weight

approx. kg

Three-phase A.C. motors

HEW DEx series

3/2

3

160M/4-2 9.0 1465 19.5 58.7 6.5 2.3 0.0542 170

10.5 2930 22.0 34.2 7.5 2.2

160L/4-2 12 1470 27.5 78.0 7.2 2.8 0.0712 189

15 2940 31.0 48.7 7.5 2.7

180M/4-2 14 1470 29 100 6.8 2.5 0.113 220

17 2940 33 55.2 7.5 2.5

180L/4-2 17 1475 35 110 6.9 2.5 0.134 240

20 2950 39 64.7 7.5 2.5

200L/4-2 20 1475 41 130 7.0 2.5 0.213 260

23 2950 46 74.5 7.5 2.5

225S/4-2 24 1480 46 155 7.0 2.5 0.362 320

28 2955 59 90.5 7.5 2.5

225M/4-2 29 1485 62 187 7.2 2.5 0.428 400

34 2960 66 110 7.6 2.6

250M/4-2 36 1485 77 232 7.1 2.4 0.875 490

45 2960 87 145 7.5 2.5

280S/4-2 46 1480 85 297 6.8 2.0 1.87 610

58 2970 95 187 7.0 2.0

280M/4-2 65 1480 128 419 6.6 1.8 2.25 685

80 2970 142 257 6.8 1.8

315S/4-2 78 1485 154 502 6.5 1.8 3.5 820

90 2970 176 289 6.0 1.7

315M/4-2 90 1485 156 579 6.5 1.8 3.8 930

100 2970 190 322 6.2 1.7

315M/4-20 100 1485 208 643 6.2 1.8 5.0 1240

120 2970 230 386 6.0 1.6

Three-phase A.C. motors

HEW DEx series

TypeConstruc-tion size

DExorDDEx

Nominaloutput

PN

kW

Nominalspeed

nN

min-1

Nominalcurrent(400V)

IN

A

Nominaltorque

MN

Nm

Starting to nominal

current

IA / IN

Breakdownto nominal

torque

MK / MN

Momentof

torque

JM

kgm²

Weight

approx. kg

3/3

71K/6-4 0.15 920 0.75 1.55 2.6 1.6 0.00051 16

0.2 1440 0.85 1.33 3.3 1.6

71L/6-4 0.21 920 1.2 2.18 2.6 2.0 0.00063 17

0.3 1420 1.35 2.02 3.4 1.9

80K/6-4 0.22 930 0.7 2.26 3.3 1.9 0.00098 25

0.32 1455 1.05 2.10 4.2 2.1

80L/6-4 0.26 940 0.94 2.64 3.5 2.2 0.00125 28

0.4 1425 1.28 2.68 3.6 1.9

90S/6-4 0.45 945 1.5 4.55 3.6 2.1 0.00204 34

0.66 1450 1.75 4.35 5.3 2.2

90L/6-4 0.6 960 1.8 5.97 3.6 2.1 0.0026 36

0.9 1425 2.1 6.03 4.4 1.9

100 L/6-4 0.9 960 2.4 8.95 4.0 1.8 0.00388 45

1.3 1420 3.0 8.74 4.5 1.9

100 L/6-40 1.1 960 2.8 10.9 4.3 1.8 0.00499 49

1.7 1450 3.7 11.2 4.7 2.1

112M/6-4 1.5 970 3.55 14.8 5.3 2.2 0.01014 64

2.4 1450 5.05 15.8 5.4 1.9

132S/6-4 2.2 965 5.05 21.8 5.7 1.9 0.02113 89

3.0 1465 6.0 19.6 6.1 2.1

132M/6-4 3.0 975 6.7 29.4 6.5 2.2 0.02793 99

4.5 1460 8.9 29.4 6.3 1.9

Three-phase A.C. motors

HEW DEx series

TypeConstruc-tion size

DExorDDEx

Nominaloutput

PN

kW

Nominalspeed

nN

min-1

Nominalcurrent(400V)

IN

A

Nominaltorque

MN

Nm

Starting to nominal

current

IA / IN

Breakdownto nominal

torque

MK / MN

Momentof

torque

JM

kgm²

Weight

approx. kg

No. of poles: 6-4 Nominal data at 400V, 50Hz Y/Y Thermal class F

Operating mode: S1 Synchronous speed: 1000-1,500min-1 Surface cooling IC411

3/4

160M/6-4 3.8 965 9.0 37.6 6.0 2.0 0.05417 155

5.7 1465 13.0 37.2 6.5 1.8

160L/6-4 5.5 980 13.3 53.6 7.0 2.1 0.07116 197

8 1480 16.8 51.6 7.0 2.0

180M/6-4 7.5 980 16.6 73.1 6.3 2.0 0.1129 220

11 1470 22 71.5 6.5 1.6

180L/6-4 9 980 20 87.7 6.5 2.0 0.1339 240

13 1470 26 84.5 7.0 1.5

200L/6-4 13 980 31 127 6.8 2.1 0.21298 260

19 1470 39 123 7.2 2.2

225S/6-4 19 980 40 185 6.0 2.0 0.36225 320

23 1470 48 149 6.3 2.2

225M/6-4 23 980 48 224 6.0 2.1 0.42845 400

27 1470 56 175 6.5 2.0

250M/6-4 27 980 53 263 6.0 2.1 0.875 490

32 1470 65 208 6.5 2.2

280S/6-4 32 985 63 310 6.5 2.3 1.875 610

45 1475 89 291 7.0 2.7

280M/6-4 37 985 72 359 6.5 2.3 2.25 685

55 1475 108 356 7.0 2.7

315S/6-4 45 985 88 436 6.8 2.1 3.9 820

67 1485 130 431 7.2 2.3

315M/6-4 55 985 108 533 6.8 2.1 3.875 930

80 1485 155 515 7.2 2.3

3

Three-phase A.C. motors

HEW DEx series

TypeConstruc-tion size

DExorDDEx

Nominaloutput

PN

kW

Nominalspeed

nN

min-1

Nominalcurrent(400V)

IN

A

Nominaltorque

MN

Nm

Starting to nominal

current

IA / IN

Breakdownto nominal

torque

MK / MN

Momentof

torque

JM

kgm²

Weight

approx. kg

3/5

63L/8-4 0.030 670 0.45 0.42 2.0 1.7 0.00043 14

0.12 1390 0.50 0.82 3.4 1.9

71K/8-4 0.048 650 0.32 0.70 2.1 1.7 0.00081 16

0.22 1370 0.57 1.53 3.8 2.0

71L/8-4 0.07 650 0.47 1.00 2.1 1.7 0.00101 17

0.32 1370 0.82 2.23 3.8 2.0

80K/8-4 0.2 690 0.83 2.77 2.8 2.0 0.00191 25

0.3 1380 0.79 2.08 3.9 2.2

80L/8-4 0.27 690 1.08 3.74 2.9 2.1 0.00239 28

0.4 1400 0.96 2.73 4.5 2.2

90S/8-4 0.42 705 1.9 5.69 2.8 2.0 0.00323 34

0.8 1390 1.9 5.50 3.9 1.8

90L/8-4 0.5 710 2.3 6.73 3.1 2.1 0.00419 36

1.0 1410 2.25 6.77 4.3 1.9

100L/8-4 0.9 690 3.05 12.5 3.2 2.1 0.00657 45

1.3 1380 3.0 9.00 4.2 2.1

100L/8-40 1.0 720 3.2 13.3 3.9 2.1 0.00857 49

1.6 1430 3.35 10.7 5.3 2.2

112M/8-4 1.5 710 4.25 20.2 4.6 2.2 0.0158 64

2.5 1430 5.0 16.7 5.7 2.1

132S/8-4 2.3 720 6.7 30.5 5.3 2.3 0.02722 89

3.6 1450 7.3 23.7 6.9 2.2

132M/8-4 3.0 720 9.5 39.8 4.5 2.3 0.03229 99

5.0 1445 9.9 33.0 5.4 2.3

Three-phase A.C. motors

HEW DEx series

No. of poles: 8-4 Nominal data at 400V, 50Hz s / YY Thermal class F

Operating mode: S1 Synchronous speed: 750-1,500min-1 Surface cooling IC411

TypeConstruc-tion size

DExorDDEx

Nominaloutput

PN

kW

Nominalspeed

nN

min-1

Nominalcurrent(400V)

IN

A

Nominaltorque

MN

Nm

Starting to nominal

current

IA / IN

Breakdownto nominal

torque

MK / MN

Momentof

torque

JM

kgm²

Weight

approx. kg

3/6

160M/8-4 4.0 725 10.5 52.7 5.2 1.8 0.08121 155

5.5 1460 10.8 36.0 7.0 1.8

160M/8-40 4.6 725 12.8 60.6 4.6 1.8 0.01092 165

7.3 1460 14.6 47.8 7.0 1.9

160L/8-4 6.8 725 21 89.6 4.8 1.8 0.10916 197

11 1460 23 72.0 7.0 2.0

180L/8-4 11 725 29 145 4.6 1.7 0.227 240

15 1460 30 98.1 7.0 2.0

200L/8-4 15 730 33 196 5.3 1.5 0.24369 260

20 1465 44 130 6.8 1.8

225S/8-4 18 730 42 236 5.3 1.6 0.5710 320

24 1465 50 157 6.8 1.8

225M/8-4 22 730 50 288 5.0 1.5 0.66117 400

28 1465 55 183 7.0 2.0

250M/8-4 30 730 67 393 4.5 1.5 1.125 490

42 1465 80 274 6.5 2.0

280S/8-4 35 735 80 455 4.6 1.6 2.3 610

51 1470 96 331 6.5 1.6

280M/8-4 42 735 88 546 5.0 1.5 2.625 685

60 1470 105 390 6.3 1.5

315S/8-4 52 740 109 671 5.0 1.6 4.625 820

68 1475 130 440 6.4 1.5

315M/8-4 70 740 147 903 5.8 1.7 5.25 930

90 1475 173 583 6.5 1.5

3

Three-phase A.C. motors

HEW DEx series

TypeConstruc-tion size

DExorDDEx

Nominaloutput

PN

kW

Nominalspeed

nN

min-1

Nominalcurrent(400V)

IN

A

Nominaltorque

MN

Nm

Starting to nominal

current

IA / IN

Breakdownto nominal

torque

MK / MN

Momentof

torque

JM

kgm²

Weight

approx. kg

3/7

90S/8-6 0.35 695 1.35 4.81 2.7 1.7 0.0323 34

0.45 960 1.5 4.48 3.3 1.8

90L/8-6 0.45 695 1.68 6.18 2.7 1.8 0.00419 36

0.6 960 2.07 5.97 3.5 2.0

100L/8-6 0.6 715 2.05 8.01 2.9 1.6 0.00657 45

0.8 970 2.15 7.88 4.1 1.8

100L/8-60 0.75 710 2.4 10.1 3.1 1.6 0.00857 49

0.9 970 2.5 8.86 4.7 2.0

112M/8-6 0.9 720 2.8 11.9 4.2 2.2 0.0158 64

1.2 970 3.0 11.8 5.1 2.4

132S/8-6 1.5 725 5.05 19.8 4.8 2.5 0.02722 89

2.0 975 5.5 19.6 6.2 2.4

132M/8-6 2.2 725 6.8 29.0 3.9 2.1 0.03229 99

3.0 975 8.1 29.4 5.3 2.2

160M/8-6 3.5 725 8.8 46.1 5.5 2.3 0.08121 155

5.0 975 12.0 49.0 6.4 2.1

160L/8-6 5.0 725 12.0 65.9 5.5 2.4 0.10916 197

7.0 975 16.0 68.6 6.5 2.2

180L/8-6 7.0 725 18 92.2 5.5 2.0 0.227 240

9.5 980 24 92.6 6.2 1.8

200L/8-6 10 725 23 132 5.5 2.3 0.24369 260

13 980 27 127 6.8 2.1

225S/8-6 13 725 29 171 5.3 1.7 0.57008 320

16 975 36 157 6.2 1.6

225M/8-6 17 725 42 224 5.4 1.7 0.66117 400

22 975 54 216 6.5 1.6

250M/8-6 22 730 51 288 5.8 1.9 1.125 490

30 985 65 291 6.5 1.6

280S/8-6 27 735 63 351 5.8 1.8 2.3 610

35 985 80 339 6.5 1.6

280M/8-6 33 735 74 429 6.0 1.8 2.625 685

41 985 90 398 6.7 1.6

315S/8-6 40 735 90 520 6.0 1.8 4.625 820

50 985 102 485 7.0 1.6

315M/8-6 48 735 103 624 6.0 1.8 5.25 930

62 985 125 601 7.0 1.6

Three-phase A.C. motors

HEW DEx series

No. of poles: 8-6 Nominal data at 400V, 50Hz Y/Y Thermal class F

Operating mode: S1 Synchronous speed: 750-1,500min-1 Surface cooling IC411

TypeConstruc-tion size

DExorDDEx

Nominaloutput

PN

kW

Nominalspeed

nN

min-1

Nominalcurrent(400V)

IN

A

Nominaltorque

MN

Nm

Starting to nominal

current

IA / IN

Breakdownto nominal

torque

MK / MN

Momentof

torque

JM

kgm²

Weight

approx. kg

Explosion-protectedthree-phase A.C. motors

(single-speed / operation with inverter)

4/1

4

63K/2 0.18 0.18 0.62 0.18 0.61 0.17 0.57 0.16 0.54 0.30 0.62 0.18 0.36 0.18 0.62

63L/2 0.25 0.25 0.86 0.25 0.86 0.23 0.78 0.22 0.74 0.42 0.86 0.25 0.50 0.25 0.86

71K/2 0.37 0.37 1.25 0.35 1.2 0.3 1 0.22 0.74 0.64 1.25 0.37 0.71 0.37 1.25

71L/2 0.55 0.55 1.9 0.52 1.8 0.45 1.5 0.33 1.1 0.96 1.9 0.55 1.1 0.55 1.9

80K/2 0.75 0.75 2.6 0.7 2.4 0.6 2 0.5 1.7 1.3 2.6 0.75 1.5 0.75 2.6

80L/2 1.1 1.1 3.7 1 3.4 0.9 3 0.75 2.5 1.9 3.7 1.1 2.1 1.1 3.7

90S/2 1.5 1.5 5 1.4 4.7 1.2 4 1 3.3 2.6 5 1.5 2.9 1.5 5

90L/2 2.2 2.2 7.4 2 6.7 1.7 5.7 1.4 4.7 3.8 7.4 2.2 4.2 2.2 7.4

100L/2 3 3 10 2.7 8.9 2.2 7.2 1.8 5.9 5.2 10 3 5.7 3 10

112M/2 4 4 13 3.7 12 3.2 11 2.5 8.2 7 13 4 7.4 4 13

132S/2 5.5 5.5 18 5 16 4.5 15 3.7 12 9.6 18 5.5 10.3 5.5 18

132M/20 7.5 7.5 25 7 23 6 20 5 16 13 25 7.5 14.2 7.5 25

160M/2 11 11 36 10 32 9 29 7.5 24 19 36 11 21 11 36

160M/20 15 14.5 47 13 42 12 39 10 32 25.2 47 14.5 27 14.5 47

160L/2 18.5 17.5 57 16 52 15 49 12.5 41 30.5 57 17.5 33 17.5 57

180M/2 22 20 65 19 62 17 56 15 49 35 65 20 37 20 65

200L/2 30 27 87 26 84 24 76 21 68 47 87 27 50 27 87

200L/20 37 33 107 32 103 28 90 26 84 56 107 33 61 33 107

225M/2 45 40 130 37 119 34 110 32 101 69 130 40 75 40 130

250M/2 55 50 159 45 145 43 138 39 124 86 159 50 91 50 159

280S/2 75 67 217 60 193 58 186 53 169 - - 67 124 67 217

280M/2 90 81 260 73 234 70 225 63 202 - - 81 150 81 260

315S/2 110 100 318 90 288 88 282 78 247 - - 100 182 100 318

315M/2 132 119 382 110 353 105 331 93 297 - - 119 219 119 382

315M/20 160 144 458 135 433 125 400 112 358 - - 144 263 144 458

315L/2 200 180 575 165 528 156 500 140 447 - - 180 330 180 575

Three-phase A.C. motors

HEW DEx series

* Operation only possible with winding version 230/400V- Winding version 230/400V from construction type 280 on request

Operation on the inverter: 2-pole motors

Operation Mains Frequency converter operation

Ventilation IC 411 IC 411 IC 411 IC 411 IC 411 IC 411 IC 411 IC 416

external van

Torque progression M ~ n2 constant constant constant constant M ~ 50/f constant

Frequency 50Hz 5 - 50Hz 20 - 50Hz 10 - 50Hz 5 - 50Hz 50 - 87Hz * 50 - 87Hz 5 - 50Hz

Synchronous speed 300 - 3000 1200 - 3000 600 - 1500 300 - 3000 3000 - 5220 3000 - 5220 300 - 3000

Setting range 1 : 10 1 : 2,5 1 : 5 1 : 10 1 : 1,74 1 : 1,74 1 : 10

Voltage / frequency U/f = constant U/f = constant U/f = constant U/f = constant U/f = constant U = constant U/f = constant

Power / torque P P/kW M/Nm P/kW M/Nm P/kW M/Nm P/kW M/Nm P/kW M/Nm P/kW M/Nm P/kW M/Nm

kW at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz

50 50 50 20 50 10 50 5 87 50-87 50-87 87 50 5-50

Type / DEx or DDEx

4/2

63K/4 0.12 0.12 0.85 0.12 0.85 0.11 0.75 0.11 0.75 0.21 0.85 0.12 0.49 0.12 0.85

63L/4 0.18 0.18 1.25 0.18 1.25 0.17 1.18 0.16 1.1 0.31 1.25 0.18 0.72 0.18 1.25

71K/4 0.25 0.25 1.7 0.22 1.5 0.19 1.25 0.18 1.2 0.43 1.7 0.25 1 0.25 1.7

71L/4 0.37 0.37 2.5 0.33 2.2 0.28 1.9 0.22 1.5 0.64 2.5 0.37 1.4 0.37 2.5

80K/4 0.55 0.55 3.8 0.52 3.5 0.45 3 0.33 2.2 0.96 3.8 0.55 2.2 0.55 3.8

80L/4 0.75 0.75 5.2 0.7 4.8 0.6 4 0.5 3.3 1.3 5.2 0.75 3 0.75 5.2

90S/4 1.1 1.1 7.5 1 6.7 0.9 6 0.75 5 1.9 7.5 1.1 4.3 1.1 7.5

90L/4 1.5 1.5 10 1.4 9.5 1.2 8 1 6.7 2.6 10 1.5 5.7 1.5 10

100L/4 2.2 2.2 15 2 13 1.7 11 1.4 9.3 3.8 15 2.2 8.5 2.2 15

100L/40 3 3 20 2.8 19 2.2 15 1.8 12 5.2 20 3 11.4 3 20

112M/4 4 4 27 3.6 24 3 20 2.5 16 7 27 4 15.4 4 27

132S/4 5.5 5.5 37 5 33 4.4 29 3.7 24 9.6 37 5.5 21 5.5 37

132M/4 7.5 7.5 50 7 46 6 39 5 33 13 50 7.5 28.5 7.5 50

160M/4 11 11 72 10 65 9 58 7.5 49 19 72 11 41 11 72

160L/4 15 15 98 13.5 88 12 78 10 65 26 98 15 56 15 98

180M/4 18.5 18 118 17 111 15 97 12.5 81 31 118 18 67 18 118

180L/4 22 21 137 20 130 18 117 15 97 37 137 21 78 21 137

200L/4 30 28 183 27 176 24 156 21 136 49 183 28 104 28 183

225S/4 37 34 220 32 206 29 188 26 168 59 220 34 126 34 220

225M/4 45 41 265 39 250 35 227 32 207 71 265 41 152 41 265

250M/4 55 50 322 48 305 43 278 39 248 86 322 50 185 50 322

280S/4 75 68 437 65 415 58 373 53 337 - - 68 251 68 437

280M/4 90 82 525 78 497 70 450 64 405 - - 82 302 82 525

315S/4 110 100 643 95 607 86 550 77 494 - - 100 369 100 643

315M/4 132 120 771 115 732 105 673 94 596 - - 120 443 120 771

315M/40 160 145 929 138 883 126 801 113 719 - - 145 534 145 929

315L/4 200 180 1157 173 1102 160 1026 140 897 - - 180 665 180 1157

Three-phase A.C. motors

HEW DEx series

Operation on the inverter: 4-pole motors

Operation Mains Frequency converter operation

Ventilation IC 411 IC 411 IC 411 IC 411 IC 411 IC 411 IC 411 IC 416

external van

Torque progression M ~ n2 constant constant constant constant M ~ 50/f constant

Frequency 50Hz 5 - 50Hz 20 - 50Hz 10 - 50Hz 5 - 50Hz 50 - 87Hz * 50 - 87Hz 5 - 50Hz

Synchronous speed 150 - 1500 600 - 1500 300 - 1500 150 - 1500 1500 - 2610 1500 - 2610 150 - 1500

Setting range 1 : 10 1 : 2,5 1 : 5 1 : 10 1 : 1,74 1 : 1,74 1 : 10

Voltage / frequency U/f = constant U/f = constant U/f = constant U/f = constant U/f = constant U = constant U/f = constant

Power / torque P P/kW M/Nm P/kW M/Nm P/kW M/Nm P/kW M/Nm P/kW M/Nm P/kW M/Nm P/kW M/Nm

kW at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz

50 50 50 20 50 10 50 5 87 50-87 50-87 87 50 5-50

Type / DEx or DDEx

* Operation only possible with winding version 230/400V- Winding version 230/400V from construction type 280 on request

4/3

63 K/6 0.09 0.09 1.0 0.08 0.89 0.07 0.78 0.06 0.67 0.15 1.0 0.09 0.58 0.09 1.0

63 L/6 0.12 0.12 1.3 0.11 1.2 0.09 0.98 0.08 0.87 0.21 1.3 0.12 0.75 0.12 1.3

71 K/6 0.18 0.18 1.9 0.15 1.6 0.13 1.3 0.11 1.1 0.32 1.9 0.18 1.1 0.18 1.9

71 L/6 0.25 0.25 2.5 0.22 2.2 0.18 1.8 0.18 1.6 0.43 2.5 0.25 1.5 0.25 2.5

80 K/6 0.37 0.37 3.8 0.33 3.4 0.27 2.7 0.22 2.2 0.64 3.8 0.37 2.2 0.37 3.8

80 L/6 0.55 0.55 5.7 0.5 5.1 0.4 4 0.33 3.3 0.95 5.7 0.55 3.3 0.55 5.7

90 S/6 0.75 0.75 7.8 0.65 6.7 0.55 5.5 0.42 4.2 1.3 7.8 0.75 4.5 0.75 7.8

90 L/6 1.1 1.1 11.4 0.9 9.2 0.8 8 0.6 6 1.9 11.4 1.1 6.6 1.1 11.4

100 L/6 1.5 1.5 15 1.4 14 1.1 11 0.9 9 2.6 15 1.5 8.6 1.5 15

112 M/6 2.2 2.2 22 2.0 20 1.7 17 1.3 13 3.8 22 2.2 13 2.2 22

132 S/6 3 3 30 2.7 27 2.2 22 1.8 18 5.2 30 3 17.5 3 30

132 M/6 4 4 40 3.5 35 3 30 2.5 25 6.9 40 4 23 4 40

132 M/60 5.5 5.5 55 4.8 48 4 40 3.3 33 9.5 55 5.5 32 5.5 55

160 M/6 7.5 7.5 74 7 69 6 59 5 49 13 74 7.5 43 7.5 74

160 L/6 11 11 110 10 98 9 88 7.5 73 19 110 11 63 11 110

180 L/6 15 14 133 13 128 12 118 10 98 24 133 14 76 15 148

200 L/6 18.5 18 171 16 157 14 137 12 118 31 171 18 98 18.5 183

200 L/60 22 20 196 19 188 17 157 15 147 35 196 20 113 22 218

225 M/6 30 27 262 25 242 23 223 21 204 47 262 27 151 30 293

250 M/6 37 34 323 32 308 29 281 26 252 59 323 34 186 37 359

280 S/6 45 41 393 39 376 35 338 32 309 - - 41 226 45 437

280 M/6 55 50 481 48 459 43 415 39 374 - - 50 276 55 534

315 S/6 75 69 672 65 629 58 571 54 512 - - 69 378 75 732

315 M/6 90 82 795 78 752 71 681 64 623 - - 82 452 90 874

315 M/60 110 100 960 96 917 87 831 78 756 - - 100 551 110 1060

315 L/6 132 120 1150 115 1100 104 997 94 906 - - 120 660 132 1275

4

Three-phase A.C. motors

HEW DEx series

Operation on the inverter: 6-pole motors

Operation Mains Frequency converter operation

Ventilation IC 411 IC 411 IC 411 IC 411 IC 411 IC 411 IC 411 IC 416

external van

Torque progression M ~ n2 constant constant constant constant M ~ 50/f constant

Frequency 50Hz 5 - 50Hz 20 - 50Hz 10 - 50Hz 5 - 50Hz 50 - 87Hz * 50 - 87Hz 5 - 50Hz

Synchronous speed 100 - 1000 400 - 1000 200 - 1000 100 - 1000 1000 - 1740 1000 - 1740 100 - 1000

Setting range 1 : 10 1 : 2,5 1 : 5 1 : 10 1 : 1,74 1 : 1,74 1 : 10

Voltage / frequency U/f = constant U/f = constant U/f = constant U/f = constant U/f = constant U = constant U/f = constant

Power / torque P P/kW M/Nm P/kW M/Nm P/kW M/Nm P/kW M/Nm P/kW M/Nm P/kW M/Nm P/kW M/Nm

kW at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz

50 50 50 20 50 10 50 5 87 50-87 50-87 87 50 5-50

Type / DEx or DDEx

* Operation only possible with winding version 230/400V- Winding version 230/400V from construction type 280 on request

4/4

63L/8 0.06 0.06 0.90 0.05 0.75 0.04 0.60 0.04 0.60 0.10 0.90 0.06 0.52 0.06 0.90

71K/8 0.09 0.09 1.25 0.08 1.1 0.07 0.96 0.06 0.83 0.16 1.25 0.09 0.72 0.09 1.25

71L/8 0.12 0.12 1.7 0.11 1.5 0.1 1.4 0.08 1.1 0.21 1.7 0.12 1.0 0.12 1.7

80K/8 0.18 0.18 2.5 0.16 2.2 0.13 1.7 0.11 1.5 0.32 2.5 0.18 1.5 0.18 2.5

80L/8 0.25 0.25 3.4 0.22 3.0 0.16 2.4 0.15 2.2 0.43 3.4 0.25 2.0 0.25 3.4

90S/8 0.37 0.37 5.1 0.33 4.4 0.27 3.6 0.22 3.0 0.64 5.1 0.37 3.0 0.37 5.1

90L/8 0.55 0.55 7.5 0.5 6.7 0.4 5.4 0.33 4.4 0.95 7.5 0.55 4.3 0.55 7.5

100L/8 0.75 0.75 10.2 0.65 8.7 0.55 7.4 0.42 5.6 1.3 10.2 0.75 5.9 0.75 10.2

100L/80 1.1 1.1 15.1 0.9 12 0.8 11 0.6 8.1 1.9 15.1 1.1 8.7 1.1 15.1

112M/8 1.5 1.5 20.2 1.4 19 1.1 15 0.9 12 2.6 20.2 1.5 12 1.5 20.2

132S/8 2.2 2.2 30 2 27 1.7 23 1.3 17 3.8 30 2.2 17.5 2.2 30

132M/8 3 3 40.5 2.7 36 2.2 29 1.8 24 5.2 40.5 3 24 3 40.5

160M/8 4 4 53.5 3.5 46 3 40 2.5 33 6.9 53.5 4 31 4 53.5

160M/80 5.5 5.5 73 4.8 64 4 53 3.3 44 9.5 73 5.5 42 5.5 73

160L/8 7.5 7.5 100 7 82 6 72 4.5 59 13 100 7.5 58 7.5 100

180L/8 11 11 146 10 131 8 104 7 91 19 146 11 84 11 146

200L/8 15 14 186 13 172 12 159 10 132 24 183 14 107 15 196

225S/8 18.5 17.5 235 16.8 225 15 200 14 188 30 233 17.5 135 18.5 249

225M/8 22 21 280 20 267 18 240 16 213 36 277 21 161 22 293

250M/8 30 28 366 27 353 24 314 22 287 48 363 28 210 30 398

280S/8 37 34 444 33 431 30 392 27 353 - - 34 255 37 485

280M/8 45 41 533 40 519 36 467 32 415 - - 41 306 45 586

315S/8 55 50 650 48 623 44 571 39 506 - - 50 374 55 716

315M/8 75 68 877 65 838 59 761 53 684 - - 68 504 75 969

315M/80 90 81 1045 77 993 70 903 63 813 - - 81 600 90 1160

315L/8 110 100 1290 95 1226 86 1110 77 994 - - 100 742 110 1420

Three-phase A.C. motors

HEW DEx series

Operation on the inverter: 8-pole motors

Operation Mains Frequency converter operation

Ventilation IC 411 IC 411 IC 411 IC 411 IC 411 IC 411 IC 411 IC 416

external van

Torque progression M ~ n2 constant constant constant constant M ~ 50/f constant

Frequency 50Hz 5 - 50Hz 20 - 50Hz 10 - 50Hz 5 - 50Hz 50 - 87Hz * 50 - 87Hz 5 - 50Hz

Synchronous speed 75 - 750 300 - 750 150 - 750 75 - 750 750 - 1305 750 - 1305 75 - 750

Setting range 1 : 10 1 : 2,5 1 : 5 1 : 10 1 : 1,74 1 : 1,74 1 : 10

Voltage / frequency U/f = constant U/f = constant U/f = constant U/f = constant U/f = constant U = constant U/f = constant

Power / torque P P/kW M/Nm P/kW M/Nm P/kW M/Nm P/kW M/Nm P/kW M/Nm P/kW M/Nm P/kW M/Nm

kW at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz at/Hz

50 50 50 20 50 10 50 5 87 50-87 50-87 87 50 5-50

Type / DEx or DDEx

* Operation only possible with winding version 230/400V- Winding version 230/400V from construction type 280 on request

Dimension sheets

5/1

SizeTypeDEx

A AA AB AC B BA BB C

63K/L 100 22 120 125 80 30 106 4071K/L 112 30 140 139 90 30 114 4580K/L 125 32 160 157 100 35 130 5090S90L

140 135 180 177100125

60 155 56

100L 160 45 205 195 140 45 175 63112M 190 50 235 219 140 50 180 70132S132M

216 55 266 258140178

75 218 89

160M160L

254 60 312 310210254

105 300 108

180M180L

279 70 350 345241279

118 333 121

200L 318 80 398 385 305 95 365 133225S225M-2225M

356 80 436 435286311311

110 371 149

250M-2250M

406 100 506 491 349 90 429 168

280S-2280S280M-2280M

457 110 557 537

368368419419

100

454454505505

190

315S-2315S315M-2315M315M-20315M0315L-2315L

508 110 628 617

406406457457457457457457

115

526526577577577577577577

216

Three-phase A.C. motors

HEW DEx series

Types DEx 63 - 315 Construction type: IM B3 / IM 1001Temperature class T1 to T4 IM V5 / IM 1011Cooling type IC 411 IM V6 / IM 1031

5/2

DDA

EEA

FFA

GCGA

H HA HD I K L LC SizeTypeDEx

11 23 4 12.5 63 8 210 105 7 238 267 63K/L14 30 5 16 71 10 218 114 9 271 307 71K/L19 40 6 21.5 80 10 249 131 10 317 362 80K/L

24 50 8 27 90 10 271 140 10 360 41590S90L

28 60 8 31 100 17 288 158 12 416 481 100L28 60 8 31 112 15 311 159 12 438 504 112M

38 80 10 41 132 18 350 181 12 534 619132S132M

42 110 12 45 160 21 436 255 14 667 685160M160L

48 110 14 51 180 22 496 297 14 704 742180M180L

55 110 16 59 200 22 546 308 18 790 830 200L605560

140110140

181618

645964

225 23 589341311341

18882852882

922892922

225S225M-2225M

6065

140 186469

250 23 687 380 24 997 1052250M-2250M

65756575

140

18201820

6979.569

79.5

280 23 744 382 24

1036103610961096

1191119112241224

280S-2280S280M-2280M

6580658065806580

140170140170140170140170

1822182218221822

6985698569856985

315 25 859

454484454484454484454484

28

10501080122012501220125013001330

12101270138014401380144014601520

315S-2315S315M-2315M315M-20315M0315L-2315L

5

Three-phase A.C. motors

HEW DEx series

5/3

5

Three-phase A.C. motors

HEW DEx series

Types DEx 63 - 315 Construction type: IM B5 / IM 3001Temperature class T1 to T4 IM V1 / IM 3011Cooling type IC 411 IM V3 / IM 3031

SizeTypeDEx

AC DDA

EEA

FFA

GCGA

HB I L LA LC M N P S X T

63K/L 125 11 23 4 12.5 147 105 238 8 267 115 95 140 9 4 371K/L 139 14 30 5 16 147 114 271 10 307 130 110 160 9 4 3.580K/L 157 19 40 6 21.5 169 131 317 10 362 165 130 200 12 4 3.590S/L 177 24 50 8 27 181 140 360 10 415 165 130 200 12 4 3.5100L 195 28 60 8 31 188 158 416 11 481 215 180 250 14 4 4112M 219 28 60 8 31 199 159 438 11 504 215 180 250 14 4 4132S/M 258 38 80 10 41 218 181 534 16 619 265 230 300 14 4 4160M/L 310 42 110 12 45 276 255 667 19 785 300 250 350 18 4 5180M/L 345 48 110 14 51 316 297 704 15 742 300 250 350 18 4 5200L 385 55 110 16 59 346 308 790 18 830 350 300 400 18 4 5225S

43560 140 18 64

364341 882

18922

400 350 450 18 8 5225M-2 55 110 16 59 311 852 892225M 60 140 18 64 341 882 922250M-2

49160

140 1864

437 380 997 18 1152 500 450 550 19 8 5250M 65 69280S-2

537

65

140

18 69

464 382

1036103610961096

18

1191119112241224

500 450 550 19 8 5280S 75 20 79.5280M-2 65 18 69280M 75 20 79.5315S-2

617

65 140 18 69

544

454 1050

18

1210

600 550 660 24 8 6

315S 80 170 22 85 484 1080 1270315M-2 65 140 18 69 454 1220 1380315M 80 170 22 85 484 1250 1440315M-20 65 140 18 69 454 1220 1380315M0 80 170 22 85 484 1250 1440315L-2 65 140 18 69 454 1300 1460315L 80 170 22 85 484 1330 1520

X number of drilled holes

5/4

5

Three-phase A.C. motors

HEW DEx series

SizeTypeDEx

AC DDA

EEA

FFA

GCGA

HB I L LC M N P S X T

63K/L 125 11 23 4 12.5 147 105 238 267 75 60 90 M5 4 2.571K/L 139 14 30 5 16 147 114 271 307 85 70 105 M6 4 2.580K/L 157 19 40 6 21.5 169 131 317 362 100 80 120 M6 4 390S/L 177 24 50 8 27 181 140 360 415 115 95 140 M8 4 3100L 195 28 60 8 31 188 158 416 481 130 110 160 M8 4 3.5112M 219 28 60 8 31 199 159 438 504 130 110 160 M8 4 3.5132S/M 258 38 80 10 41 218 181 534 619 165 130 200 M8 4 3.5160M/L 310 42 110 12 45 276 255 667 785 215 180 250 M12 4 4

X number of drilled holes

Types DEx 63 - 315 Construction type: IM B14 / IM 3001Temperature class T1 to T4 IM V18 / IM 3011Cooling type IC 411 IM V19 / IM 3031

M

5/5

Three-phase A.C. motors

HEW DEx series

Types DEx 63 - 315 Construction type: IM B35 / IM 2001Temperature class T1 to T4 IM V15 / IM 2011Cooling type IC 411 IM V35 / IM 2031

SizeTypeDEx

A AA AB AC B BA BB C DDA

EEA

FFA

GCGA

H

63K/L 100 22 120 125 80 30 106 40 11 23 4 12.5 6371K/L 112 30 140 139 90 30 114 45 14 30 5 16 7180K/L 125 32 160 157 100 35 130 50 19 40 6 21.5 8090S90L

140 135 180 177100125

60 155 56 24 50 8 27 90

100L 160 45 205 195 140 45 175 63 28 60 8 31 100112M 190 50 235 219 140 50 180 70 28 60 8 31 112132S132M

216 55 266 258140178

75 218 89 38 80 10 41 132

160M160L

254 60 312 310210254

105 300 108 42 110 12 45 160

180M180L

279 70 350 345241279

118 333 121 48 110 14 51 180

200L 318 80 398 385 305 95 365 133 55 110 16 59 200225S225M-2225M

356 80 436 435286311311

110 371 149605560

140110140

181618

645964

225

250M-2250M

406 100 506 491 349 90 429 1686065

140 186469

250

280S-2280S280M-2280M

457 110 557 537

368368419419

100

454454505505

190

65756575

140

18201820

6979.569

79.5

280

315S-2315S315M-2315M315M-20315M0315L-2315L

508 110 628 617

406406457457457457457457

115

526526577577577577577577

216

6580658065806580

140170140170140170140170

1822182218221822

6985698569856985

315

X number of drilled holes

M

5/6

5

Three-phase A.C. motors

HEW DEx series

HA HD I K L LÀ LC M N P S X T SizeTypeDEx

8 210 105 7 238 8 267 115 95 140 9 4 3 63K/L10 218 114 9 271 10 307 130 110 160 9 4 3.5 71K/L10 249 131 10 317 10 362 165 130 200 12 4 3.5 80K/L

10 271 140 10 360 10 415 165 130 200 12 4 3.590S90L

17 288 158 12 416 11 481 215 180 250 14 4 4 100L15 311 159 12 438 11 504 215 180 250 14 4 4 112M

18 350 181 12 534 16 619 265 230 300 14 4 4132S132M

21 436 255 14 667 19 685 300 250 350 18 4 5160M160L

22 496 297 14 704 15 742 300 250 350 18 4 5180M180L

22 546 308 18 790 18 830 350 300 400 18 4 5 200L

23 589341311341

18882852882

18922892922

400 350 450 18 8 5225S225M-2225M

23 687 380 24 997 18 1052 500 450 550 19 8 5250M-2250M

23 744 382 24

1036103610961096

18

1191119112241224

500 450 550 19 8 5

280S-2280S280M-2280M

25 859

454484454484454484454484

28

10501080122012501220125013001330

12101270138014401380144014601520

600 550 660 24 8 6

315S-2315S315M-2315M315M-20315M0315L-2315L

X number of drilled holes

5/7

5

Three-phase A.C. motors

HEW DEx series

Types DEx 63 - 315 Construction type: IM B34 / IM 2001Temperature class T1 to T4 IM V17 / IM 2011Cooling type IC 411 IM V37 / IM 2031

SizeTypeDEx

A AA AB AC B BA BB C DDA

EEA

FFA

GCGA

63K/L 100 22 120 125 80 30 106 40 11 23 4 12.571K/L 112 30 140 139 90 30 114 45 14 30 5 1680K/L 125 32 160 157 100 35 130 50 19 40 6 21.590S90L

140 135 180 177100125

60 155 56 24 50 8 27

100L 160 45 205 195 140 45 175 63 28 60 8 31112M 190 50 235 219 140 50 180 70 28 60 8 31132S132M

216 55 266 258140178

75 218 89 38 80 10 41

160M160L

254 60 312 310210254

105 300 108 42 110 12 45

SizeTypeDEx

H HA HD I K L LC M N P S X T

63K/L 63 8 210 105 7 238 267 75 60 90 M5 4 2,571K/L 71 10 218 114 9 271 307 85 70 105 M6 2,580K/L 80 10 249 131 10 317 362 100 80 120 M6 4 390S90L

90 10 271 140 10 360 415 115 95 140 M8 4 3

100L 100 17 288 158 12 416 481 130 110 160 M8 4 3,5112M 112 15 311 159 12 438 504 130 110 160 M8 4 3,5132S132M

132 18 350 181 12 534 619 165 130 200 M8 4 3,5

160M160L

160 21 436 255 14 667 685 215 180 250 M12 4 4

X number of drilled holes

M

Dimension sheetsCustomized motors

6/1

6

Three-phase A.C. motors

HEW DEx series

Types DEx 63 - 315 Special version Temperature class T1 to T4Cooling type IC 411

SizeTypeDEx

AC D E F GC HB1 HB2 L LA M N P S X T Weight(4pole-B3)

[approx. kg]63K/L 125 11 23 4 12.5 147 169 383 10 115 95 140 9 4 3 28 / 2971K/L 139 14 30 5 16 147 169 417 10 130 110 160 9 4 3.5 31 / 3280K/L 157 19 40 6 21.5 169 199 515 12 165 130 200 12 4 3.5 56 / 5890S/L 177 24 50 8 27 181 199 558 12 165 130 200 12 4 3.5 66 / 69100L/L0 195 28 60 8 31 188 224 632 14 215 180 250 14 4 4 93 / 96112M 219 28 60 8 31 199 224 654 14 215 180 250 14 4 4 110132S/M 258 38 80 10 41 218 249 777 18 265 230 300 14 4 4 162 / 172160M/L 310 42 110 12 45 276 249 911 18 300 250 350 18 4 4 241 / 260180M/L 345 48 110 14 51 316 267 1009 21 300 250 350 18 4 4 350 / 371200L 385 55 110 16 59 346 267 1098 21 350 300 400 18 4 4 400225S

43560 140 18 64

364 267 1154 21 400 350 450 18 8 4485

225M-2 60 140 16 59 550225M 60 140 18 64 565

X number of drilled holes

The motors of construction size 63-225 can be supplied with an optional brake (see page 1/23)

6/2

6

Three-phase A.C. motors

HEW DEx series

Types DEx 63 - 315 Special version Temperature class T1 to T4Cooling type IC 411

SizeTypeDEx(Motor 1)

Motor 2( Type )

AC 1 AC2 L1 Weight (4pole-B3)

[approx. in kg]

80K/L 71K/2 159 139 614 44 / 4690S/L 71K/2 180 139 637 52 / 55100L/L0 71K/2 198 139 695 63 / 66112M 71K/2 222 139 726 81132S/M 71K/2 261 139 822 106 / 116160M/L 71K/2 317 139 954 188 / 207180M/L 80K/4 355 157 1026 256 / 277200L 80K/4 391 157 1135 296225S

80K/4 439 1571218 360

225M-2 1184 425225M 1218 440250M-2

90L/4 491 177 1380528

250M 523280S-2

90L/4 537 177

1422 695280S 1422 655280M-2 1482 745280M 1482 730315S-2

90L/4 617 177

1429 867315S 1459 867315M-2 1599 977315M 1629 977315M-20 1599 1287315M-0 1629 1287315L-2 1679 1427315L 1709 1427

The motors of size 80-315 can be supplied with an optional exter-nal fan (see page 1/22).

6/3

6

Three-phase A.C. motors

HEW DEx series

Types DEx 63 - 315 Special version Temperature class T1 to T4Cooling type IC 411

SizeTypeDEx

AC L Weight(4pole-B3)

[approx. in kg]63K/L 125 353 15 / 1671K/L 139 386 17 / 1880K/L 157 435 26 / 2890S/L 177 478 34 / 37100L/L0 195 534 45 / 48112M 219 556 62132S/M 258 640 86 / 96160M/L 310 788 161 / 180180M/L 345 828 217 / 238200L 385 940 252225S 435 1025 312225M-2 995 377225M 1025 392250M-2 491 On request 487250M 482280S-2 537 On request 652280S 612280M-2 702280M 687315S-2 617 On request 822315S 822315M-2 932315M 932315M-20 1242315M0 1242315L-2 1382315L 1382

Motors of size 63-315 can be supplied with an optional hollow shaft encoder (see page 1/23).

6/4

Types DEx 63 - 315 Special version: Temperature class T1 to T4Cooling type IC 411

SizeTypeDEx

L H Weight(4pole-B3)

[approx. in kg]63K/L 238 112 9 / 10 71K/L 271 112 11 / 1280K/L 317 126 20 / 2290S/L 360 135 28 / 31100L/L0 416 142 38 / 42112M 438 154 56132S/M 534 179 80 / 89160M/L 667 211 147 166180M/L 704 256 203 / 224200L 790 288 238225S 882

308298

225M-2 852 363225M 882 378

Motors of constructional size 63-225 can be supplied with an optional direct cable connection instead of a terminal box (cable length as per customer request)

Three-phase A.C. motors

HEW DEx series

HerforderElektromotoren-WerkeGoebenstraße 10632051 Herford

[email protected] +49(0) 5221 5904 - 41fax +49(0) 5221 5904 - 34