12-lead Electrocardiogram

Page 2: 12 lead electrocardiogram

Overview

*A 12-lead electrocardiogram (ECG) provides information about the electrical system of the heart from 12 different views, or leads. Common uses of a 12-lead ECG include diagnosis of acute coronary syndromes, identification of dysrhythmias, and determination of the effects of medications or electrolytes on the electrical system of the heart.

*There are SIX chest ( precordial ) leads & FOUR limb leads.

Page 3: 12 lead electrocardiogram

Important considerations

*Check cables and lead wires for fraying, broken wires or discoloration before placement.

*It may be necessary to clip chest hair to ensure good skin contact with the electrode.

*Respiratory artifact can be common in doing the chest leads and may require position changes to ensure a good baseline. If sequential (serial) ECGs are to be obtained, chest lead sites should be marked to ensure that the same lead sites are used in subsequent ECGs. Some pregelled electrodes can be left in place for repeat ECGs.

Page 4: 12 lead electrocardiogram

*The supine position is best, but Fowler or other positions may be used for comfort. ECGs should be recorded in the same position each time to ensure that tracing changes are not caused by changes in body position. If another position is clinically required, note the position on the tracing or in the comments of the LCD input. Do not compromise lead placement because of a medication patch. Relocate the medication patch before applying the leads.

*Expose only the necessary parts of the patients legs, arms, and chest. This Provides privacy and warmth, which reduces anxiety, shivering and resulting artifacts.

Page 5: 12 lead electrocardiogram

*Clean the intended sites with alcohol pads, cleansing pads or soap and water, and dry thoroughly since moist skin is not conducive to electrode adherence.

*When applying the electrodes they must be secure to prevent external influences from affecting the ECG. The pregelled electrodes must be moist and adhesive to allow for appropriate conduction of impulses.

*Ensure that the patient is in the supine position, not touching the bedrails or footboard which may increase the chance of distortion of the trace.

Page 6: 12 lead electrocardiogram

ECG critical value reporting

*The following are the critical values that require reporting ( depends on your institution)

1- VT/VF

2- ST elevation, injury pattern

3- High degree AVB ( AV dissociation, 2:1 AV block, 3rd degree block )

4- Severe bradycardia ( HR < 40 bpm )

Page 7: 12 lead electrocardiogram

STAT ECGs

*You can perform an ECG stat in Extremely Urgent situations. However, All ECGS need to have: date of birth, tech initial ASAP afterwards. You also need to hold off transmitting the tracing until all information is complete. So please make sure you enter this info as soon as you get it.

Page 8: 12 lead electrocardiogram

Identifying lead sites: Chest leads placement

**NOTE: The leads are listed out of numerical order, intentionally because it facilitates easier lead placement.

*Identify the angle of Louis or the sternal notch. This assists with identifying the second rib for correct placement of precordial leads in the appropriate intercostal space ( ICS ).

*Slight alterations in the position of any of the precordial leads may alter the ECG significantly and can have impact on diagnosis and treatment.

Page 9: 12 lead electrocardiogram

V1 :*Palpate the upper sternum to identify where the clavicle joins the sternum (suprasternal notch). Slide fingers down the center of the sternum to the obvious bony prominence. This is the sternal notch, or angle of Louis which serves as your landmark. Move directly to the Right(of the patient ) and you will feel a gap. That gap is the second intercostal space. Slide your fingers down over the rib until you feel the next gap. This is the third intercostal space. Move down over one more rib and into the next gap, the fourth intercostal space.

This is where V1 is to be placed.

Page 10: 12 lead electrocardiogram

V2 :*Lead V2 is to placed directly across from V1 in the fourth ICS, on the left side of the sternum.

V4 :*Lead V4 is placed in the 5th intercostal space, midclavicular.

V3 :*Lead V3 is placed directly horizontally & equidistant in between Leads V2 and V4.

Page 11: 12 lead electrocardiogram

V6 :*Lead V6 is placed in the 5th intercostal space, midaxillary horizontally level with V4 .

V5 :*Lead V5 is placed horizontally & equidistant in between leads V4 and V6 (anterior axillary line )

please see the following illustration

Page 12: 12 lead electrocardiogram

Diagram showing the correct placement for a 12-LEAD ECG.

Source: University of Nottingham

Page 13: 12 lead electrocardiogram

Identifying lead sites: Limb lead placement

Limb leads should be placed in fleshy areas, and bony prominences should be avoided. The limb

leads should be positioned in approximately the

same place on each limb.

*Note : I have noticed the technicians in the Cardiopulmonary Care Center place the lower limb leads on the lower abdomen.

*please see the following illustration

Page 14: 12 lead electrocardiogram

Limb lead placement in 12-lead ECG

Source : Mosby’s Nursing procedures & skills

Page 15: 12 lead electrocardiogram

Obtaining the trace

*The ECG must be marked accurately and have a clear baseline without artifact for correct interpretation. Three to six seconds are all that are needed for a permanent record; a longer strip may be obtained if a rhythm strip is needed. A rhythm strip is a long recording of a lead; lead II is commonly used.

*When connecting the wires to the Leads please double check the right wire to the matching lead. You will notice that the sequence is :

RA, V1, V2, V3, V4, V5, V6, LA on one side &

RL, LL on the other side.

Page 16: 12 lead electrocardiogram

Quick Reminders

*If you forget any of the steps or the sequence, a quick reference with 2 diagrams is printed on the ECG machine surface (most machines). In summary, you will enter the patient information first, then place the leads, connect them, then record a trace.

*Remember to plug the ECG machine after use please.

*Anyone in the health field setting can learn how to do a 12-Lead ECG. It just takes practice.

Page 17: 12 lead electrocardiogram

*Here is a link for a short video ( 4 minutes 25 sec. ) that demonstrates the whole procedure. Copy this link & paste it in your window please.

http://elscontent.webinservice.com/NursingSkills/Animations/CC_057/AnimationPlayer.html

Page 18: 12 lead electrocardiogram

Fun Facts :

*ECG stands for Electrocardiogram, which originally came from the German word elektrokardiogramm. 

*this is where the acronym EKG comes from. The German elektrisch means “electrical,” kardio means “heart,” and the Hungarian gramm means “measure of mass.” The two acronyms ECG and EKG are used interchangeably; however, ECG tends to sound like another common medical acronym, EEG, or Electroencephalogram. For this reason some medical professionals prefer to say EKG.

*-LEAD EKGs are similar to standard EKGs ( monitor ) except that they are more accurate & look at the heart through more angles.

Page 19: 12 lead electrocardiogram

Why are 12-LEAD EKGs important?

*According to recent estimates by the American Heart Coronary heart disease caused approximately 1 of every 6 deaths in the United States in 2006. Coronary heart disease mortality in 2006 was 425 425. In 2010, an estimated 785 000 Americans will have a new coronary attack, and approximately 470 000 will have a recurrent attack. It is estimated that an additional 195 000 silent first myocardial infarctions occur each year. Approximately every 25 seconds, an American will have a coronary event, and approximately every minute, someone will die of one. Prehospital 12-LEAD EKGs are allowing patients to reach definitive care immediately upon arrival at their local emergency department.

Page 20: 12 lead electrocardiogram

References :

*Jacobson, C. (1996). Bedside cardiac monitoring. In: AACN Research Based Practice Protocol, Technology Series. Aliso Viejo, CA: American Association of Critical Care Publications, 1-32.

*Drew, B.J. (2002). Celebrating the 100th birthday of the electrocardiogram: Lessons learned from research in cardiac monitoring. Am J Crit Care, 11, 378-86.

*Circulation 2010, 121:e46-e215: Heart Disease and Stroke Statistics--2010 Update : A Report From the American Heart Association originally published online December 17, 2009.

*Excerpted and adapted from AACN Procedure Manual for Critical Care, Fifth Edition, American Association of Critical-Care Nurses, edited by Debra J. Lynn-McHale Wiegand, PhD, RN, CCRN, FAAN, and Karen K. Carlson, MN, RN, CCNS, St. Louis: Elsevier/Saunders, 2005.

Page 21: 12 lead electrocardiogram

Thank you for your continuous

effortsto participate, be part of the team and be ready to do an ECG when needed.

Perform an ECG,Make a difference,

Save a life.