120 student dorm e adjumani
DESCRIPTION
Architectural PlanTRANSCRIPT
-
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
0017-08-12Cover Page
Drawing ListSheet No. Sheet Name
00 Cover Page02 Ground Floor03 First Floor04 Roof Plan Layout05 Front and Rear Elevations06 Side Elevations07 Section A08 Ridge Detail09 Eaves Detail10 Door & Window Schedules11 Room Finishes Schedule12 Door Detail 113 Door Detail 214 Window Detail15 Burglar proof Detail 116 Burglar proof Detail 217 Ablutions Layout18 Ablution(wc)-Sectional Elevetion119 Ablution(wc)-Sectional Elevetion220 Ablution(sho.)-Sectional Elevetion321 Staircase layout 122 Staircase layout 223 Staircase-sectional Elevation 124 Staircase-Sectional Elevation 2
Perspective 11
Perspective 22
Dormitory interior3
L01-TECHNICAL VOCATIONAL EDUCATION &TRAINING (TVET-SFD) PROJECT PROPOSED STUDENT DORMITORY - AMELO TECHNICAL INSTITUTE, ADJUMANI
-
UP
UP
C D F G
2
3
5
B E
4
4400
1600
4400
4400
A
07
27 mLobby
2
15 mVerandah
1
178 m60-Bed Dormitory
4
3600 3600 3600 3600 3600 3600 3600 5800 5800
1480
0
H I J
1480
0
36800
900
750
900
750
900
36800
3600 3600 3600 3600 3600 3600 3600 5800 5800
A
1
W227 m
Reading Rm3
64 mAblution
5600 2170 600
1
14 15
21
25
----
117
225 3375 225 3375 225 17775 225 2195 150 3990 1501145
100
1145
1001150
1001150
225
121
700 2400 1200 2400 1200 2400 1200 2400 1200 2400 1200 2400 1200 2400 725
D2 D2
D6D6D6D6 D6
D4
D4
D3
D1
W1
W1W1 W1 W1 W1
W1W1 W1 W1 W1
W2
W1W1
700 2400 720 3400 680 2400 1200 2400 1200 2400 1200 2400 1200 2400 725
225
5775
225
8575
225
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 1250217-08-12
Ground Floor
1 : 12501- Ground Floor
1
-
DN
DN
C D F G
2
3
5
B E
4
A
07
H I J
4400
1600
4400
4400
1040
044
0036800
3600 3600 3600 3600 3600 3600 3600 5800 5800
36800
3600 3600 3600 3600 3600 3600 3600 5800 5800
1040
044
00
4400
1600
4400
A
12 mBedroom2
9
14 mLounge
7
4 mwc/sh
10
1
12 mBedroom1
8
177 m60-Bed Dormitory
11
65 mAblution
12
225 1800 150 1425 225 3375 225 17775 225
122
D2D2
D6D6D6D6 D6
D3
D5
D3
D3
D3
W1
W1W1
W1
W1 W1 W1
W1 W1 W1W1W1
W3
W1W1
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 1250317-08-12
First Floor
1 : 12502- First Floor
1
-
C D F G
2
3
5
B E
4
A
07
4400
1600
4400
4400
3600 3600 3600 3600 3600 3600 3600 5800 5800
1480
0
H I J
3600 33200
33200
3600 3600 3600 3600 3600 3600 5800 5800
4400
1600
4400
4400
1480
0
A
1
Total Roof Area = 492.0 sq.mfascia Board Length = 105.0 mGutter Length =105.0 mRidge length = 26.4mHip Length = 43.0mValley Length = 6.1 m
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 1250417-08-12
Roof Plan Layout
1 : 12503 - Roof Level
1
-
01- Ground Floor0
03 - Roof Level6000
C D F GB E
00 - Foundation Level-1350
H I J
02- First Floor3000
A
01- Ground Floor0
03 - Roof Level6000
CDFG BE
00 - Foundation Level-1350
HIJ
02- First Floor3000
A
1 : 125Front Elevation
1
1 : 125Rear Elevation
2
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 1250517-08-12
Front and Rear Elevations
-
01- Ground Floor0
03 - Roof Level6000
235 4
02- First Floor3000
1
01- Ground Floor0
03 - Roof Level6000
2 3 54
02- First Floor3000
1
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 1000617-08-12
Side Elevations
1 : 100Side Elevation 2
2
1 : 100Side Elevation 1
1
-
01- Ground Floor0
03 - Roof Level6000
2 3 54
00 - Foundation Level-1350
02- First Floor3000
178 m60-Bed Dormitory
4
177 m60-Bed Dormitory
11
ROOF CONSTRUCTION
Roof pitch 20 degreesPre-painted metal ridge cap onGauge 26 prepainted IT5 roofing sheets on100mm deep steel Z purlins on40x80x3mm steel truss rafter member on40x40x3mm ties and struts on40x80x3mm tiebeam onmetal anchor plate embedded in concrete ringbeam
FOUNDATION DETAILS
100mm thick reinforced concrete floor slab on50mm sand blinding on150mm treated well rammed hardcore bed onwell rammed murram backfill on225X675mm concrete strip foundationsColumn footings as per structural engineers detail.Foundation depth to be determined on site
10400
5200
500
1400
1100
500
1400
1100
500
1400
1250
350
1400
1100
2891
3000
108
109
3000
3000
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 500717-08-12
Section A
1 : 50Section A
A
-
4010
080
4040
80100
40
Gauge 26 pre-painted ridge cappingwith end overlaps of 150mm minimum,screewed onto steel purlins at 450mmintervals
Anti-bat rubber filler beneath ridgecap fixed in place with approved selftapping screws
Approved self tapping screws
100mm deep Z purlin to receive IT5Roofing sheets
40 x 80 x 3mm thick m.s rectangularhollow section truss rafter
40 x 40 x 3mm thick m.s square hallowsection truss ties and struts
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 100817-08-12
Ridge Detail
1 : 10Ridge Detail
1
-
03 - Roof Level6000
5
1200
1150 50
40 x 80x 3mm thick m.s rectangularhallow section truss rafter
40 x 40 x 3mm thick m.s squarehallow section truss ties and struts
1.5mm thick x 210mm pre-formedm.s plate fascia board welded toangle cleats at rafter ends
150mm thick brick beam filling in 1:4cement sand mortar plastered neatwith no adulterations to underside ofroofing sheets
9mm plywood ceilingboard
225 x 150mm x 450mm longconcrete hollow block aspermanent roof vent, backedinternally with anti-bat coffee traymesh
Aluminium coffee tray mesh fixedonto 25 x 25mm timber beadingand plugged firm into brickwork
50 x 100mm pressureimpregnated softwood Joists
6000 109
278
80
300
254
225
214
4080
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 100917-08-12
Eaves Detail
1 : 10Eaves Detail
1
-
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1017-08-12Door & Window Schedules
Door ScheduleType Mark Width Height Count Description
D1 1500 2500 1 Double Leaf Steel Casement Door with fixed sidelightsD2 1200 2100 4 Double Leaf Steel Casement Door, pv overD3 900 2100 5 Solid Core Flush Door, pv overD4 900 2100 2 Solid Steel Panelled Door, pv overD5 800 2100 1 Solid Core Flush Door, pv overD6 800 2050 10 Solid Core Flush Door, pv over
Window ScheduleType Mark Width Height Count Description
W1 2400 1400 27 Steel Casement Window, Pv overW2 900 2000 2 Low Level Casement Strip Window, pv overW3 900 1200 1 Steel Casement Window, pv over
-
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1117-08-12Room Finishes Schedule
Room Finishes ScheduleName Number Count Area Floor Finish Wall Finish Ceiling Finish Perimeter
Verandah 1 1 15 m Cement Sand Screed Plaster & Paint 9mm thick Plywood Ceiling board 18360Lobby 2 1 27 m Cement Sand Screed Plaster & Paint 9mm thick Plywood Ceiling board 22969Reading Rm 3 1 27 m Cement Sand Screed Plaster & Paint 9mm thick Plywood Ceiling board 2312560-Bed Dormitory 4 1 178 m Cement Sand Screed Plaster & Paint 9mm thick Plywood Ceiling board 70857Ablution 5 1 64 m Terrazzo Ceramic Wall Tiles to 1800mm 9mm thick Plywood Ceiling board 82924Lounge 7 1 14 m Cement Sand Screed Plaster & Paint 9mm thick Plywood Ceiling board 15175Bedroom1 8 1 12 m Cement Sand Screed Plaster & Paint 9mm thick Plywood Ceiling board 15375Bedroom2 9 1 12 m Cement Sand Screed Plaster & Paint 9mm thick Plywood Ceiling board 14175wc/sh 10 1 4 m Terrazzo Ceramic Wall Tiles to 1800mm 9mm thick Plywood Ceiling board 872560-Bed Dormitory 11 1 177 m Cement Sand Screed Plaster & Paint 9mm thick Plywood Ceiling board 69900Ablution 12 1 65 m Terrazzo Ceramic Wall Tiles to 1800mm 9mm thick Plywood Ceiling board 83674
-
60 850 40 1500 40 850 60
410
5010
3910
41
2540
D1 - 3400 x 2500Double leaf steel casement French door400mm deep steel louvre vents. Extensionhinges, standard Z section frames, Brassdead locks as union UK complete withfurniture. 6mm clear sheet glazing. Steel doorframes
Steel louvred vents
6mm clear sheet glass
3400
D2 - 1200 x 2500Double leaf timber casement door400mm deep fanlight. 150mm s.s butthinges, 110mm x 40mm thick door style.Approved casement door lock as unionUK complete with furniture. 6mm clearsheet glazing. hardwood door frames
6mm frostedglazing
6mm clearsheet fixedglass fanlight
38mm thicktimber mullion
600 600
1200
2500
400
1050
1050
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 201217-08-12
Door Detail 1
1 : 20Door Detail 1
-
2500
400
2100
45 810 45
900
D3 - 900 x 2500Solid core flush door 810mm wide single leafshutter 45 x 140mm timber door frame. 400mmdeep fanlight with 16mm dia. m.s horizontalburglar bars 150mm steel butt hinges. Approved3 lever mortice lock complete with furniture.6mm clearance gap from f.f.l at bottom style
16mm dia. m.s bar
45 x 140mm timber frame
solid core flush door
Aluminium mosquitonetting
2500
400
2100
45 810 45
900
D4 - 900 x 2500Single leaf Solid Steel panelled door810mm wide shutter, 45 x 140mm steeldoor frame. 400mm deep permanent vent,150mm steel butt hinges. approved 3lever mortice lock complete with furniture.6mm clearance gap from f.f.l at bottomstyle
1mm thick steellouvre blades at65mm verticalspacing
2500
400
2100
45 710 45
800
D5 - 800 x 2500Solid core flush door 710mm wide,single leaf shutter 45 x 140mm timberdoor frame. 400mm deep fixed fanlightover
45 x 140mmtimber frame
solid coreflush door
fixed fanlight
2050
200
1650
200
D6 - 800 x 2500Solid core flush door 710mm wide,single leaf shutter 45 x 140mm timberdoor frame set at 200mm above f.f.l.Steel butt hinges. approved indicatorlock complete with furniture
45 710 45
800
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 201317-08-12
Door Detail 2
1 : 20Door Detail 2
-
W1 - 2400 x 1400Steel casement top hung window, completewith Heavy duty Al. friction hinges andfasteners to detail 4mm clear sheet glazing.Burglar proofing welded to window framesinternally to detail
1400
400
500
500
1200 1200
2400
2000
400
340
420
420
420
W2 - 900 x 2000Steel casement top hung strip window,complete with Heavy duty Al. friction hingesand fasteners to detail 4mm clear sheetglazing. Burglar proofing welded to windowframes internally to detail
900
70 760 70
800
400
1200
70 760 70
900
W3 - 900 x 1200Steel casement Top hung window,complete with heavy duty Al. friction hingesand fasteners to detail 5mm clear sheetglazing. Burglar proofing welded to windowframes internally to detail
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 201417-08-12
Window Detail
1 : 20Window Detail
-
175
165
165
165
165
140
380
1355
SectionElevation
25x4mm thick flatbar framing allround
12mm solidround mild steelbar through25x4mm flat bar
12mm dia.m.s round barconnector
Plan
75 500 80 500 90 500 80 500 75
2400
12mm solidround mild steelbar through25x4mm flat bar
25x4mm thick flatbar framing allround
12mm dia.m.s round barconnector
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 201517-08-12
Burglar proof Detail 1
1 : 20Burglar proof Detail
-
115
165
165
165
165
165
165
165
165
140
Section
25x4mm thick flatbar framing allround
12mm solidround mild steelbar through25x4mm flat bar
12mm dia.m.s round barconnector
Section
25x4mm thick flatbar framing allround
12mm solidround mild steelbar through25x4mm flat bar
12mm dia.m.s round barconnector
Plan
75 335 80 335 75
900
Elevation
12mm solidround mild steelbar through25x4mm flat bar
25x4mm thick flatbar framing allround
12mm dia.m.s round barconnector
140
165
165
165
140
25x4mm thick flat barframing all round
12mm solid roundmild steel barthrough 25x4mmflat bar
Elevation
25x4mm thick flat barframing all round
12mm solid round mild steelbar through 25x4mm flat bar
Plan
900
75 335 80 335 75
380
380
1155
1955
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 201617-08-12
Burglar proof Detail 2
1 : 20Burglar proof Detail 2
-
3
5
4
H I J
64 mAblution
5
400 x 150 x 75mmhigh concreteupstand
Concreteironing slab
Double gangsockets 1100mmabove finished floorlevel
50mm dia. GI pipes
400 x 65mm thick grade 25concrete work bench
Workbench
65mm outletgrating cat
200 x 115mm block floorchannel
560 x 425 x 255mmdeep heavy duty Belfastsink in enamelled fireclay
Floo
r Dra
in to
Fal
l 1800 400 1200 400 1211 150 950 150 950 150 950 150 950 150 1220 225
S3550 (1605000) Andria sqautting WC panas Armitage Shanks complete with S3580(165001A) P trap, S3740 (42200JE) Regalhigh level cistern, 6litre capacity with freeFreeflo plastic syphon fittings 12mmMicrovalve HP/LP ballvalve, side supply,internal overflow, Simpla inlet connectorS8330 (8146000) wall mount for exposedplumbing
S5095 (75490BH) Screw-to-wall anti-theft toilet roll holder as AmitageShanks with chrome plated finish andtheft proof holder
-
1
225
1240
100
900
100
1675
150
1610
225
225 2195 150 3990 150 1145 100 1145 100 1150 100 1150 225
1
940 825 1655 825 795
150 650 1090 650 100 650 1100 650
20
1
Ceramic soap dish
Chromium plate shower rosecomplete with concealed g.i riser
GT
GT GT GT
125mm wide x 75mmdeep floor drain to fallGT
GT
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 501717-08-12
Ablutions Layout
1 : 50Ablutions Layout
1
-
01- Ground Floor0
I J
02- First Floor3000
S3740 (42200JE) Regal highlevel cistern, 6litre capacity withfree Freeflo plastic syphonfittings 12mm Microvalve HP/LPballvalve, side supply, internaloverflow,
38mm diametre g.iflush pipe
Heavy duty steel clampsscrewed to wall
S5095 (75490BH) Screw-to-wallanti-theft toilet roll holder asAmitage Shanks with chromeplated finish and theft proofholder
45x145mm coping ontotop of 100mm wall
500
400
300
1800
64 mAblution
5
Approved 200x400mm x6mm thickhigh quality ceramic wall tileslayed to 1800mm height fromfinished floor level
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 251817-08-12
Ablution(wc)-Sectional Elevetion1
1 : 25Ablution(wc)-Sectional Elevetion1
1
-
01- Ground Floor0
5
02- First Floor3000
64 mAblution
5
S3740 (42200JE) Regal highlevel cistern, 6litre capacity withfree Freeflo plastic syphonfittings 12mm Microvalve HP/LPballvalve, side supply, internaloverflow,
S3550 (1605000) Andria sqauttingWC pan as Armitage Shankscomplete with S3580 (165001A) Ptrap, S3740 (42200JE) Regal highlevel cistern, 6litre capacity withfree Freeflo plastic syphon fittings12mm Microvalve HP/LP ballvalve,side supply, internal overflow,Simpla inlet connector S8330(8146000) wall mount for exposedplumbing
38mm diametre g.iflush pipe
S5095 (75490BH) Screw-to-wall anti-theft toilet rollholder as Amitage Shankswith chrome plated finishand theft proof holder
45x145mm coping ontotop of 100mm wall
193
307
400
300
1800
400
4520
55
530 1080
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 251917-08-12
Ablution(wc)-Sectional Elevetion2
1 : 25Ablution(wc)-Sectional Elevetion2
1
-
01- Ground Floor0
J
64 mAblution
545x145mm copingonto top of 100mmwall
1800
300
400
Approved 200x400mmx6mm thick high qualityceramic wall tiles layed to1800mm height fromfinished floor level
Chromium plate showerrose complete withconcealed g.i riser
Ceramic soap dish
2000
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 252017-08-12
Ablution(sho.)-Sectional Elevetion3
1 : 25Ablution(sho.)-Sectional Elevetion3
1
-
UP
C
5
B
4
1200 2400 1200
275
275
275
275
275
275
275
275
275
275
1510
1510
275
275
275
275
275
275
275
275
2751
2
3
4
5
6
7
8
9 10
11
12
13
14
15
16
17
18
19
1510 355 1510
W1
27 mLobby
2- 1
1
60 x 75mm handrail in wrotNkalati, screwed to40x150x6mm thick m.s flatbar with 20mm dia. m.sround bar anchored into wallto detail
25x50mm m.s verticalbaluster welded to steelbase plate with anchorbolts embeded into floorslab
20mm dia. x 2mm thickm.s c.h.s batustradethrough vertical balustersat 150mm c/c and finishedwith approved spray paint
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 252117-08-12
Staircase layout 1
1 : 25Staircase layout 1
1
-
DN
C
5
B
4
1
2
3
4
5
6
7
8
9 10
11
12
13
14
15
16
17
18
19 275
275
275
275
275
275
275
275
275
275
1510
1510 355 1510
1510
275
275
275
275
275
275
275
275
275
W1
60 x 75mm handrail in wrotNkalati, screwed to40x150x6mm thick m.s flatbar with 20mm dia. m.sround bar anchored into wallto detail
25x50mm m.s verticalbaluster welded to steelbase plate with anchorbolts embeded into floorslab
20mm dia. x 2mm thickm.s c.h.s batustradethrough vertical balustersat 150mm c/c and finishedwith approved spray paint
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 252217-08-12
Staircase layout 2
1 : 25Staircase layout 2
1
-
01- Ground Floor0
5 4
02- First Floor3000
1280
1720
1100
150
275
27 mLobby
2
1250
350
1400
1100
60 x 75mm handrail in wrotNkalati, screwed to40x150x6mm thick m.s flatbar with 20mm dia. m.sround bar anchored into wallto detail
25x50mm m.s verticalbaluster welded to steelbase plate with anchorbolts embeded into floorslab
20mm dia. x 2mm thickm.s c.h.s batustradethrough vertical balustersat 150mm c/c and finishedwith approved spray paint
150
275
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 252317-08-12
Staircase-sectional Elevation 1
1 : 25Staircase-Sectional Elevation 1
1
-
01- Ground Floor0
CB
02- First Floor3000
930
500
1220
350
930
500
1000
150
150
150
150
150
150
150
150
150
150
15103551510
27 mLobby
2
60 x 75mm handrail in wrotNkalati, screwed to40x150x6mm thick m.s flatbar with 20mm dia. m.sround bar anchored into wallto detail
25x50mm m.s verticalbaluster welded to steel baseplate with anchor boltsembeded into floor slab
20mm dia. x 2mm thickm.s c.h.s batustradethrough vertical balustersat 150mm c/c and finishedwith approved spray paint50
010
0015
00
PROJECT:
Plot 4 Kanjokya Street, KamwokyaP . o . Box 8493, KampalaPhone: 540140, Phone/Fax 540131
CONSULTANT
Architects, Engineers & Project ManagersPlot 103, Bukoto Street, P .o. Box 12461 Kampala
Tel: 531565, Fax 531566, [email protected]
ARCHITECT
Amelo Technical Institute,Adjumani 01
A1206-TVET
Scale
Drawn
Date
Checked
dwg no
revision
L01-The Republic Of Uganda
Saudi Fund for DevelopmentMinistry of FinanceMinistry of Education & Sports
DRAWING:
Site No.
File Ref.
MBW Consulting Ltd Arch Forum LtdB
Infrastructure and Training SuppliesRelated Consultancy Services for theConstruction and Equiping of 5 NewTechnical Institutes
krlmk
1 : 252417-08-12
Staircase-Sectional Elevation 2
1 : 25Staircase-Sectional Elevation 2
1