    One of the Worlds largest cable manufacturing plants currently built to suit the global demand in the field of Energy and Telecommunications.

    It is also a nations leading environment-friendly plant that can not only manufacture wide range of Power Cables from MV/LV to EHV but is

    also able to produce all sort of telecommunication cables and industrial products at all levels.

    Through more than 56 years of its core business in the field of power and telecommunication cables, TAIHAN is gearing up to be a global

    leading solution provider.

    Based on its corporate values of harmony and trust, we will share our vision with our stakeholders, employees, customers and our investors.

    TAIHAN will definitely bring a more prosperous future in the years to come.

    TAIHAN's All - New Production Plant in DangJin

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    4/42

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    5/42

    Introduction of XLPE Cable & AccessoriesIntroduction

    Cable Specification

    XLPE CableDesign and Construction of XLPE Cable

    ManufacturingManufacturing Process

    VCV Line

    CDCC System

    Quility Assurance & Test Requirement

    Engineering

    System Design and Engineering Work

    Installation

    Accessor ies

    Diagnosis System

    AppendixCertificates

    7

    8

    10

    20

    21

    22

    24

    25

    27

    29

    34

    38

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    6/42

    6

    TAIHAN provides turnkey cabling solutionsto ensure the reliability of energy networks

    Having led the establishment of the nations power network for the half-century, TAIHAN has led the development of

    extra high voltage cables since the 1970s and been recognized for the world class technology in XLPE underground

    cable. We have continued to increase its technology to 230kV and 345kV XLPE cables through advancement of

    technology and facilities. In step with the ever increasing power consumption and the expansion of extra high

    voltage cable demand, we reinforced the production capacity by equipping the 125 meters high VCV Tower, to

    produce high quality extra high voltage XLPE cable up to 500kV grade. Furthermore, we produce and supply quality

    accessories and joints materials for extra high voltage cables. From raw materials, production process, testing of

    products, to network design & installation, we have strictly controlled the quality of products and elevated ourselves

    to an extra high voltage cable specialist trusted by the worlds major markets including Asia, Middle East, US, and

    Australia.

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    7/42

    Introduction of XLPE Cable

    XLPE(Cross-Linked Polyethylene) insulated cables have been widely used for electric power distribution of voltage

    up to 30kV grade since they were develpoed in 1960 to replace the paper insulated cables and other thermoplastic

    insulated cables. XLPE cables have many excellent characteristics, especially for use in higher operating

    temperature. Generally PE insulated cables can be used in maximum operating temperature of 70C and paper

    insulated cables in 85C, but XLPE cables, which have more compact crystallity than PE by cross-linking process,

    can be used up to 90C in normal condition.

    The major merits of XLPE cables can be illustrated as follows;

    XLPE cab les, however, had been scarcely used for ext ra high vol tage exceed ing 30kV grade because of its

    weakness for water treeing phenomena which occurs in the insulation in long-term operating situation. Water

    treeing is a phenomena of gradual insulation destroying due to water concentration onto some weak points in the

    insulation.

    The water can be invaded through the polymeric materials in gaseous states and /or contained in insulation

    materials together with small voids and impurities during extrusion, steam-curing and cooling process. These

    waters can be con-centrated onto weak points due to high electric intensity and repeating switching operation, and

    eventually formed a treeshaped tunnel from inside to outer surface of insulation.

    But nowadays, with the aid of technical development in cable manufacturing field, water treeing phenomena

    cannot be an obstacle any more to extent the voltage grade higher. Water invasion from the outside of cable can be

    prevented by adopting water-proof seamless metal sheath and water contents in insulation during manufacturing

    process can be practically minimized by adopting dry curing cross-linking process instead of steam-curing method.

    Many researches and develpoments are accomplished in many develpoed countries including ourselves and it

    shows excellent operating experiences. 66kV and 77kV grade XLPE cables have already been used since early

    1970s and now XLPE cables up to and including 230kV grade are popularly being adopted for power transmission

    lines. 345kV grade and 500kV grade cables are also developed and under operations.

    Introduction of XLPE CableIntroduction

    7

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    8/42

    Introduction of XLPE Cable

    Introduction of XLPE CableCables Specification

    ScopeThis specification applies to materials and constructions of cross-linked

    polyethylene(XLPE) cables for extra high voltage transmission of rated voltage

    from 66kV grade upto and including 500kV grade. This specification deals

    manufacturers standard models of the cable, however any other models as for

    buyers standard are also available.

    ConductorThe conductor shall be formed from plain copper or aluminum complying with

    Korean Standard KS C 3101, British Standard 6360/6791, IEC Publication 60228or ICEA S-108-720. The conductor shall be stranded circular, compacted circular,

    or segmental compacted circular. Segmental compacted circular conductors shall

    be applied to cables of conductor nominal cross-sectional areas of 800mm2 and

    above.

    Conductor ShieldingConductor shielding of an extruded semi-conducting thermosetting compound

    shall be applied over the conductor. One or two layer of semi-conducting tape(s)

    may be applied with a proper lapping between the conductor and the extruded

    semi-conducting layer.

    InsulationThe insulation shall be of dry-cured XLPE compound with a thickness to meet

    dimensional, electrical and physical requirements specified. The compound

    shall be high quality, heat-,moisture-, ozone- and resitant. This insulation shall

    be suitable for operation in wet or dry locations at conductor temperature not

    exceeding 90C for normal condition, 130C for emergency overload conditions

    and 250C for short circuit conditions.

    Insulation ThicknessThe insulation thickness of XLPE cable must be based on its ability to withstand

    lightening impulse voltage as well as operating voltage throughout its expected

    life. For the design of XLPE cable, the nominal thickness of insulation is

    determined by AC withstand voltage(VAC) or impulse withstand voltage(Vimp),that can be determined by following formula. Larger value of TAC and Timp

    should be determined as minimum thickness of insulation.

    Insulation ShieldingThe insulation shielding shall be applied direct upon the insulation and shall

    consist of either a semiconducting tape or a layer of extruded semi-conducting

    compound, or combination of these materials. The extruded semiconducting

    compound shall be a ther-mosetting or thermosetting compound and firmly and

    totally bonded to the insulation.

    Matallic LayerThe metallic layer can be applied over the insulation shielding to reinforce the

    capability of carrying fault current specified, if required. The metallic layer will be

    one of the next forms; (Fig.1)

    Fig.1

    Copper Wire Shield Type

    Metallic Sheath Type

    Copper Wire Shield & Lead Alloy

    Sheath Type

    Insulated Wires, Copper Wire Shield & Lead

    Sheath Type (Enamelled Copper Wire Cable)

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    9/42

    Introduction of XLPE Cable

    Inner Plastic BeddingIf required, extruded layer of a thermoplastic compound, PVC or PE canbe applied.

    Metal Tape Moisture BarrierWhen the moisture barrier required, a layer of aluminum tape laminated at both or outer side with copolymer shall

    be applied longitudinally over the cable core with an overlap so as to lap parts of the tape on each other.

    Outer JacketThe outer jacket shall consist of thermoplastic compound(PVC, PE or similar materials) extruded continuously over

    the metallic layer or moisture barrier. A bituminous compound primer shall be applied under the outer jacket to

    protect the sheath against local corrosion when corrugated aluminum sheath or lead alloy sheath is adopted.

    Copper Wire Shield (CWS)When a layer of copper wire shield is required, it shall be applied directly over the insulation shielding with a length

    of lay of approximately 10 times the diameter over the screen conductors and with gaps not less than 0.1mm, if

    not specified. One or more layers of suitable separator tape may be applied helically over a layer of CWS.

    Corrugated AluminumWhen the corrugated aluminum sheath is required, it shall be applied by extrusion and then passing through a

    corrugating head. The corrugating head contains rotating dies to form the valleys between the ribs like sine wave

    and produce to correct diameter of sheath to fit over the insulation. The sheath shall be free from pinholes flaws

    and other imperfections. When the aluminum sheath is applied directly over the extruded semi-conducting layer

    or inner plastic bedding, suitable non-metallic tape(s) can be applied under the aluminum sheath to prevent heat

    transfer onto the plastic material during the manufacturing.

    Lead AlloyWhen the lead alloy sheath is required, it shall be applied by a continuous screw extrusion in high quality, smooth

    surface and free from pinholes and any other imperfections including one associated with oxide inclusions. When

    the lead sheath is applied directly over the extruded semi-conducting layer or inner plastic bedding, suitable non-

    magnetic tape(s) can be applied under the lead sheath to prevent heat transfer onto the plastic material during themanufacturing. The composition of lead alloy of composition of Cu 0.04%, Te 0.04% and the remainder for lead

    will be applied.

    9

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    10/42

    XLPE CableDesign and Construction of XLPE Cable

    Construction

    TAC= VAC/EL(AC), Timp = Vimp/EL(imp)

    Where,VAC: AC withstand voltage

    Vimp : Impulse withstand voltage

    1) Value of EL

    EL(AC) : minimum breakdown stress obtained from weibull distribution plot for AC.

    (kV/mm)

    EL(imp): minimum breakdown stress obtained from weibull distribution for impulse.

    (kV/mm)

    2) Value of VAC

    *VAC = 3 x 1.1 x k1 x k2 x k3

    Where,

    E0 : Nominal voltage(kV)

    K1: Safety factor

    K2: Deterioration coefficient of XLPE cable under electrical stresses

    K3: Temperature coefficient corresponding to the ratio of break down stresses of the

    cable at room temperature to those at maximum permissible temperature(90C)

    3) Value of Vimp

    Vimp = BIL x K'1x K'2x K'3

    Where,

    BIL : Basic impulse level (kV)

    k'1: Safety factor

    k'2: Deterioration coefficient of XLPE cable under electrical stresses

    k'3: Temperature coefficient corresponding to the ratio of breakdown stresses of the

    cable at room temperature to those at maximum permissible temperature (90C)

    EHV XLPE Cable

    E0 1.5

    0

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    11/42

    EHV XLPE Cable

    Design and Construction of XLPE Cable66kV Single Core Cable

    Construction : Copper Conductor / XLPE Insulation / Aluminum Sheath / PVC (or PE) Outer Sheath

    [Aluminum Sheath Type]

    [Copper Wire Shield Type]

    Construction : Copper Conductor / XLPE Insulation / Copper Wire Shield / PVC (or PE)

    Outer Sheath

    200

    250

    325

    400

    500

    600

    800

    1000

    1200

    1400

    1600

    1800

    2000

    NominalArea

    [mm]

    Conductor

    Shape

    Approx.

    Thickness

    of

    ConductorShield

    [mm]

    C.C

    C.C

    C.C

    C.C

    C.C

    C.C

    SEG

    SEG

    SEG

    SEG

    SEG

    SEG

    SEG

    1.0

    1.0

    1.0

    1.0

    1.0

    1.0

    2.0

    2.0

    2.0

    2.0

    2.0

    2.0

    2.0

    Thickness

    of

    Insulation[mm]

    Approx.

    Thickness

    of

    InsulationShield

    [mm]

    Thickness

    of

    Sheath[mm]

    Thickness

    of

    Jacket[mm]

    Overall

    Dia.[mm]

    Approx.Weight

    (kg / m)

    11.0

    11.0

    11.0

    11.0

    11.0

    11.0

    11.0

    11.0

    11.0

    11.0

    11.0

    11.0

    11.0

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.6

    1.6

    1.7

    1.7

    1.8

    1.9

    2.0

    2.1

    2.1

    2.2

    2.3

    2.3

    3.5

    3.5

    3.5

    3.5

    3.5

    3.5

    3.5

    3.5

    3.5

    3.5

    3.5

    3.5

    3.5

    64.0

    67.0

    70.0

    74.0

    76.0

    80.0

    87.0

    92.0

    98.0

    101.0

    105.0

    108.0

    111.0

    5.2

    5.9

    7.0

    8.1

    9.1

    10.4

    13.2

    15.6

    18.0

    20.3

    22.5

    24.5

    26.9

    * C.C : Circular Compacted, SEG : Segmental Compacted

    200

    250

    325

    400

    500

    600

    800

    1000

    1200

    14001600

    1800

    2000

    NominalArea

    [mm]

    Conductor

    Shape

    Approx.

    Thickness

    of

    ConductorShield

    [mm]

    C.C

    C.C

    C.C

    C.C

    C.C

    C.C

    SEG

    SEG

    SEG

    SEGSEG

    SEG

    SEG

    1.0

    1.0

    1.0

    1.0

    1.0

    1.0

    2.0

    2.0

    2.0

    2.02.0

    2.0

    2.0

    Thickness

    of

    Insulation[mm]

    Approx.

    Thickness

    of

    InsulationShield

    [mm]

    No.

    of

    Wire

    [mm]

    Thickness

    of

    Jacket[mm]

    Overall

    Dia.[mm]

    Approx.Weight

    (kg / m)

    11.0

    11.0

    11.0

    11.0

    11.0

    11.0

    11.0

    11.0

    11.0

    11.011.0

    11.0

    11.0

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.51.5

    1.5

    1.5

    40

    40

    40

    40

    40

    40

    40

    40

    40

    4040

    40

    40

    3.5

    3.5

    3.5

    4.0

    4.0

    4.0

    4.5

    4.5

    4.5

    4.54.5

    4.5

    4.5

    56.0

    58.0

    60.0

    64.0

    67.0

    69.0

    77.0

    81.0

    85.0

    89.092.0

    95.0

    98.0

    4.5

    5.1

    5.9

    6.9

    8.0

    9.1

    11.7

    13.7

    15.7

    17.919.8

    21.8

    23.8

    * C.C : Circular Compacted, SEG : Segmental Compacted

    Dia.

    of

    Wire

    [mm]

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    1.21.2

    1.2

    1.2

    11

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    12/42

    EHV XLPE Cable

    Design and Construction of XLPE Cable77kV Single Core Cable

    [Aluminum Sheath Type]

    [Copper Wire Shield Type]

    Construction : Copper Conductor / XLPE Insulation / Aluminum Sheath / PVC (or PE) Outer Sheath

    200

    250

    325

    400

    500

    600

    800

    1000

    1200

    1400

    1600

    1800

    2000

    NominalArea

    [mm]

    Conductor

    Shape

    Approx.

    Thickness

    of

    ConductorShield

    [mm]

    C.C

    C.C

    C.C

    C.C

    C.C

    C.C

    SEG

    SEG

    SEG

    SEG

    SEG

    SEG

    SEG

    1.0

    1.0

    1.0

    1.0

    1.0

    1.0

    2.0

    2.0

    2.0

    2.0

    2.0

    2.0

    2.0

    Thickness

    of

    Insulation[mm]

    Approx.

    Thickness

    of

    InsulationShield

    [mm]

    Thickness

    of

    Sheath[mm]

    Thickness

    of

    Jacket[mm]

    Overall

    Dia.[mm]

    Approx.Weight

    (kg / m)

    13.0

    13.0

    13.0

    13.0

    13.0

    13.0

    13.0

    13.0

    13.0

    13.0

    13.0

    13.0

    13.0

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.6

    1.6

    1.7

    1.8

    1.8

    1.9

    2.0

    2.1

    2.2

    2.2

    2.3

    2.3

    2.4

    3.5

    3.5

    3.5

    3.5

    3.5

    3.5

    3.5

    3.5

    3.5

    3.5

    3.5

    3.5

    3.5

    69.0

    72.0

    75.0

    78.0

    81.0

    84.0

    92.0

    97.0

    102.0

    106.0

    110.0

    112.0

    116.0

    5.2

    6.6

    7.5

    8.5

    9.6

    10.9

    14.0

    16.4

    18.7

    21.0

    23.3

    25.2

    27.7

    * C.C : Circular Compacted, SEG : Segmental Compacted

    Construction : Copper Conductor / XLPE Insulation / Copper Wire Shield / PVC (or PE)

    Outer Sheath

    200

    250

    325

    400

    500

    600

    800

    1000

    1200

    14001600

    1800

    2000

    NominalArea

    [mm]

    Conductor

    Shape

    Approx.

    Thickness

    of

    ConductorShield

    [mm]

    C.C

    C.C

    C.C

    C.C

    C.C

    C.C

    SEG

    SEG

    SEG

    SEGSEG

    SEG

    SEG

    1.0

    1.0

    1.0

    1.0

    1.0

    1.0

    2.0

    2.0

    2.0

    2.02.0

    2.0

    2.0

    Thickness

    of

    Insulation[mm]

    Approx.

    Thickness

    of

    InsulationShield

    [mm]

    No.

    of

    Wire

    [mm]

    Thickness

    of

    Jacket[mm]

    Overall

    Dia.[mm]

    Approx.Weight

    (kg / m)

    13.0

    13.0

    13.0

    13.0

    13.0

    13.0

    13.0

    13.0

    13.0

    13.013.0

    13.0

    13.0

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.51.5

    1.5

    1.5

    40

    40

    40

    40

    40

    40

    40

    40

    40

    4040

    40

    40

    3.5

    3.5

    3.5

    4.0

    4.0

    4.0

    4.5

    4.5

    4.5

    4.54.5

    4.5

    4.5

    60.0

    62.0

    64.0

    67.0

    70.0

    73.0

    81.0

    86.0

    90.0

    94.097.0

    100.0

    103.0

    4.8

    5.3

    6.2

    7.2

    8.3

    9.4

    12.1

    14.2

    16.3

    18.420.4

    22.4

    24.4

    * C.C : Circular Compacted, SEG : Segmental Compacted

    Dia.

    of

    Wire

    [mm]

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    1.21.2

    1.2

    1.2

    2

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    13/42

    EHV XLPE Cable

    Design and Construction of XLPE Cable110kV Single Core Cable

    [Aluminum Sheath Type]

    Construction : Copper Conductor / XLPE Insulation / Aluminum Sheath / PVC (or PE) Outer Sheath

    400

    500

    630

    800

    1000

    1200

    2000

    NominalArea

    [mm]

    Conductor

    Shape

    Approx.

    Thickness

    ofConductor

    Shield[mm]

    C.C

    C.C

    C.C

    SEG

    SEG

    SEG

    SEG

    1.5

    1.5

    1.5

    2.0

    2.0

    2.0

    2.0

    Thickness

    ofInsulation

    [mm]

    Approx.

    Thickness

    ofInsulation

    Shield[mm]

    Thickness

    ofSheath

    [mm]

    Thickness

    ofJacket

    [mm]

    Overall

    Dia.[mm]

    Approx.

    Weight(kg / m)

    15.0

    15.0

    15.0

    15.0

    15.0

    15.0

    15.0

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    1.8

    1.9

    2.0

    2.1

    2.2

    2.3

    2.5

    4.0

    4.0

    4.0

    4.0

    4.0

    4.0

    4.0

    83

    86

    92

    97

    102

    108

    122

    9.3

    10.8

    12.7

    15.4

    17.9

    20.2

    29.6

    * C.C : Circular Compacted, SEG : Segmental Compacted* Fault Current Capacity(40kA/1sec)

    [Copper Wire Shield & Lead Sheath Type]

    Construction : Copper Conductor / XLPE Insulation / Copper Wire Shield / Lead Sheath /

    PVC (or PE) Outer Sheath

    400

    500

    630

    8001000

    1200

    2000

    Nominal

    Area

    [mm]

    Conductor

    Shape

    Approx.

    Thicknessof

    Conductor

    Shield

    [mm]

    C.C

    C.C

    C.C

    SEGSEG

    SEG

    SEG

    1.5

    1.5

    1.5

    2.02.0

    2.0

    2.0

    Thicknessof

    Insulation

    [mm]

    Approx.

    Thicknessof

    Insulation

    Shield

    [mm]

    No.

    ofWire

    [mm]

    Thicknessof

    Jacket

    [mm]

    OverallDia.

    [mm]

    Approx.

    Weight

    (kg / m)

    15.0

    15.0

    15.0

    15.015.0

    15.0

    15.0

    1.2

    1.2

    1.2

    1.21.2

    1.2

    1.2

    2.0x67ea

    2.0x70ea

    1.9x67ea

    1.8x70ea1.8x65ea

    1.7x67ea

    1.4x70ea

    4.0

    4.0

    4.0

    4.04.0

    4.0

    4.0

    81

    84

    88

    9498

    102

    115

    15.5

    17.4

    19.3

    22.825.6

    28.1

    39.1

    * C.C : Circular Compacted, SEG : Segmental Compacted

    * Fault Current Capacity(40kA/1sec)

    Dia.

    ofWire

    [mm]

    2.5

    2.6

    2.7

    2.93.0

    3.1

    3.5

    13

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    14/42

    EHV XLPE Cable

    Design and Construction of XLPE Cable132kV Single Core Cable

    [Aluminum Sheath Type]

    [Copper Wire Shield & Lead Sheath Type]

    Construction : Copper Conductor / XLPE Insulation / Aluminum Sheath / PVC (or PE) Outer Sheath

    400

    500

    630

    800

    1000

    1200

    2000

    NominalArea

    [mm]

    Conductor

    Shape

    Approx.

    Thickness

    ofConductor

    Shield[mm]

    C.C

    C.C

    C.C

    SEG

    SEG

    SEG

    SEG

    1.5

    1.5

    1.5

    2.0

    2.0

    2.0

    2.0

    Thickness

    ofInsulation

    [mm]

    Approx.

    Thickness

    ofInsulation

    Shield[mm]

    Thickness

    ofSheath

    [mm]

    Thickness

    ofJacket

    [mm]

    Overall

    Dia.[mm]

    Approx.

    Weight(kg / m)

    16

    16

    16

    16

    16

    16

    16

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    1.9

    2.0

    2.1

    2.2

    2.3

    2.3

    2.6

    4.0

    4.0

    4.0

    4.0

    4.0

    4.0

    4.0

    88

    92

    96

    102

    109

    113

    126

    9.8

    11.2

    13.1

    15.7

    18.4

    20.4

    29.9

    * C.C : Circular Compacted, SEG : Segmental Compacted* Fault Current Capacity(40kA/1sec)

    Construction: Copper Conductor / XLPE Insulation / Copper Wire Shield / Lead Sheath / PVC (or PE) Outer Sheath

    400

    500

    630

    8001000

    1200

    2000

    Nominal

    Area

    [mm]

    Conductor

    Shape

    Approx.

    Thicknessof

    Conductor

    Shield

    [mm]

    C.C

    C.C

    C.C

    SEGSEG

    SEG

    SEG

    1.5

    1.5

    1.5

    2.02.0

    2.0

    2.0

    Thicknessof

    Insulation

    [mm]

    Approx.

    Thicknessof

    Insulation

    Shield

    [mm]

    No.

    ofWire

    [mm]

    Thicknessof

    Jacket

    [mm]

    OverallDia.

    [mm]

    Approx.

    Weight

    (kg / m)

    16

    16

    16

    1616

    16

    16

    1.2

    1.2

    1.2

    1.21.2

    1.2

    1.2

    2.0x67ea

    1.9x70ea

    1.9x67ea

    1.8x67ea1.7x70ea

    1.7x65ea

    1.4x65ea

    4.0

    4.0

    4.0

    4.04.0

    4.0

    4.0

    82

    85

    89

    9599

    103

    116

    15.5

    17.2

    19.4

    22.625.4

    27.9

    38.8

    * C.C : Circular Compacted, SEG : Segmental Compacted

    * Fault Current Capacity(40kA/1sec)

    Dia.

    ofWire

    [mm]

    2.5

    2.6

    2.7

    2.93.0

    3.1

    3.5

    4

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    15/42

    EHV XLPE Cable

    Design and Construction of XLPE Cable154kV Single Core Cable

    [Aluminum Sheath Type]

    [Copper Wire Shield & Lead Sheath Type]

    Construction : Copper Conductor / XLPE Insulation / Aluminum Sheath / PVC (or PE) Outer Sheath

    600

    1200

    2000

    2500

    Nominal

    Area

    [mm]

    Conductor

    Shape

    Approx.

    Thicknessof

    Conductor

    Shield

    [mm]

    C.C

    SEG

    SEG

    SEG

    1.5

    2.0

    2.0

    2.0

    Thicknessof

    Insulation

    [mm]

    Approx.

    Thicknessof

    Insulation

    Shield

    [mm]

    Thicknessof

    Sheath

    [mm]

    Thicknessof

    Jacket

    [mm]

    OverallDia.

    [mm]

    Approx.

    Weight

    (kg / m)

    17

    17

    17

    17

    1.3

    1.3

    1.3

    1.3

    2.9

    2.5

    2.6

    2.8

    4.5

    4.5

    4.5

    4.5

    103

    115

    127

    135

    15.0

    21.8

    31.2

    36.2

    * C.C : Circular Compacted, SEG : Segmental Compacted* Fault Current Capacity(50kA/1.7sec)

    Construction: Copper Conductor / XLPE Insulation / Copper Wire Shield / Lead Sheath /

    PVC (or PE) Outer Sheath

    6001200

    2000

    2500

    NominalArea

    [mm]

    Conductor

    Shape

    Approx.

    Thickness

    ofConductor

    Shield

    [mm]

    C.CSEG

    SEG

    SEG

    1.52.0

    2.0

    2.0

    Thickness

    ofInsulation

    [mm]

    Approx.

    Thickness

    ofInsulation

    Shield

    [mm]

    No.

    of

    Wire[mm]

    Thickness

    ofJacket

    [mm]

    Overall

    Dia.[mm]

    Approx.

    Weight

    (kg / m)

    1717

    17

    17

    1.31.3

    1.3

    1.3

    2.6x70ea2.5x65ea

    2.3x68ea

    2.2x66ea

    4.54.5

    4.5

    4.5

    95109

    122

    129

    22.731.7

    42.7

    48.5

    * C.C : Circular Compacted, SEG : Segmental Compacted

    * Fault Current Capacity(40kA/1sec)

    Dia.

    of

    Wire[mm]

    2.93.3

    3.6

    3.8

    15

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    16/42

    EHV XLPE Cable

    Design and Construction of XLPE Cable230kV Single Core Cable

    [Aluminum Sheath Type]

    [Copper Wire Shield & Lead Sheath Type]

    Construction: Copper Conductor / XLPE Insulation / Aluminum Sheath / PVC (or PE) Outer Sheath

    600

    1200

    2000

    2500

    Nominal

    Area

    [mm]

    Conductor

    Shape

    Approx.

    Thicknessof

    Conductor

    Shield[mm]

    C.C

    SEG

    SEG

    SEG

    1.5

    2.0

    2.0

    2.0

    Thicknessof

    Insulation

    [mm]

    Approx.

    Thicknessof

    Insulation

    Shield[mm]

    Thicknessof

    Sheath

    [mm]

    Thicknessof

    Jacket

    [mm]

    Overall

    Dia.

    [mm]

    Approx.

    Weight(kg / m)

    23

    23

    23

    23

    1.3

    1.3

    1.3

    1.3

    2.4

    2.6

    2.9

    3.0

    5.0

    5.0

    5.0

    5.0

    117

    132

    146

    153

    16.8

    24.2

    34.1

    39.1

    * C.C : Circular Compacted, SEG : Segmental Compacted* Fault Current Capacity (63kA/1sec)

    Construction: Copper Conductor / XLPE Insulation / Copper Wire Shield / Lead Sheath /

    PVC (or PE) Outer Sheath

    6001200

    2000

    2500

    Nominal

    Area

    [mm]

    Conductor

    Shape

    Approx.

    Thicknessof

    Conductor

    Shield

    [mm]

    C.CSEG

    SEG

    SEG

    1.52.0

    2.0

    2.0

    Thicknessof

    Insulation

    [mm]

    Approx.

    Thickness

    ofInsulation

    Shield

    [mm]

    No.

    ofWire

    [mm]

    Thicknessof

    Jacket

    [mm]

    OverallDia.

    [mm]

    Approx.

    Weight

    (kg / m)

    2323

    23

    23

    1.31.3

    1.3

    1.3

    2.3x66ea2.2x68ea

    2.0x65ea

    1.9x65ea

    5.05.0

    5.0

    5.0

    108121

    134

    141

    25.735.0

    46.7

    52.4

    * C.C : Circular Compacted, SEG : Segmental Compacted

    * Fault Current Capacity(63kA/1sec)

    Dia.

    ofWire

    [mm]

    3.23.6

    4.0

    4.1

    6

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    17/42

    EHV XLPE Cable

    Design and Construction of XLPE Cable345kV Single Core Cable

    [Aluminum Sheath Type]

    [Copper Wire Shield & Lead Sheath Type]

    Construction: Copper Conductor / XLPE Insulation / Aluminum Sheath / PVC (or PE) Outer Sheath

    600

    1200

    2000

    2500

    Nominal

    Area

    [mm]

    Conductor

    Shape

    Approx.

    Thicknessof

    Conductor

    Shield[mm]

    C.C

    SEG

    SEG

    SEG

    1.5

    2.0

    2.0

    2.0

    Thicknessof

    Insulation

    [mm]

    Approx.

    Thicknessof

    Insulation

    Shield[mm]

    Thicknessof

    Sheath

    [mm]

    Thicknessof

    Jacket

    [mm]

    Overall

    Dia.

    [mm]

    Approx.

    Weight(kg / m)

    27

    27

    27

    27

    1.3

    1.3

    1.3

    1.3

    3.0

    2.8

    3.0

    3.2

    6.0

    6.0

    6.0

    6.0

    132

    143

    157

    165

    19.3

    27.4

    37.5

    43.0

    * C.C : Circular Compacted, SEG : Segmental Compacted* Fault Current Capacity(63kA/1.7sec)

    Construction : Copper Conductor / XLPE Insulation / Copper Wire Shield / Lead Sheath /

    PVC (or PE) Outer Sheath

    6001200

    2000

    2500

    NominalArea

    [mm]

    Conductor

    Shape

    Approx.

    Thickness

    ofConductor

    Shield

    [mm]

    C.CSEG

    SEG

    SEG

    1.52.0

    2.0

    2.0

    Thickness

    ofInsulation

    [mm]

    Approx.

    Thickness

    ofInsulation

    Shield

    [mm]

    No.

    of

    Wire[mm]

    Thickness

    ofJacket

    [mm]

    Overall

    Dia.[mm]

    Approx.

    Weight

    (kg / m)

    1717

    17

    17

    1.31.3

    1.3

    1.3

    2.9x84ea2.9x81ea

    2.9x78ea

    2.9x75ea

    6.06.0

    6.0

    6.0

    119132

    145

    153

    31.241.1

    53.0

    60.2

    * C.C : Circular Compacted, SEG : Segmental Compacted

    * Fault Current Capacity(63kA/1.7sec)

    Dia.

    of

    Wire[mm]

    3.13.4

    3.7

    3.9

    17

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    18/42

    EHV XLPE Cable

    Design and Construction of XLPE Cable380/400kV Single Core Cable

    [Aluminum Sheath Type]

    [Copper Wire Shield & Lead Sheath Type]

    Construction : Copper Conductor / XLPE Insulation / Aluminum Sheath / PVC (or PE) Outer Sheath

    600

    1200

    2000

    2500

    Nominal

    Area

    [mm]

    Conductor

    Shape

    Approx.

    Thicknessof

    Conductor

    Shield

    [mm]

    C.C

    SEG

    SEG

    SEG

    1.5

    2.0

    2.0

    2.0

    Thicknessof

    Insulation

    [mm]

    Approx.

    Thicknessof

    Insulation

    Shield

    [mm]

    Thicknessof

    Sheath

    [mm]

    Thicknessof

    Jacket

    [mm]

    OverallDia.

    [mm]

    Approx.

    Weight

    (kg / m)

    29

    29

    27

    27

    1.5

    1.5

    1.5

    1.5

    2.6

    2.9

    3.0

    3.2

    6.0

    6.0

    6.0

    6.0

    132

    146

    157

    165

    19.9

    27.6

    37.5

    43.8

    * C.C : Circular Compacted, SEG : Segmental Compacted* Fault Current Capacity(63kA/1sec)

    Construction :Copper Conductor / XLPE Insulation / Copper Wire Shield / Lead Sheath /

    PVC (or PE) Outer Sheath

    6001200

    2000

    2500

    NominalArea

    [mm]

    Conductor

    Shape

    Approx.

    Thickness

    ofConductor

    Shield

    [mm]

    C.CSEG

    SEG

    SEG

    1.52.0

    2.0

    2.0

    Thickness

    ofInsulation

    [mm]

    Approx.

    Thickness

    ofInsulation

    Shield

    [mm]

    No.

    of

    Wire[mm]

    Thickness

    ofJacket

    [mm]

    Overall

    Dia.[mm]

    Approx.

    Weight

    (kg / m)

    2929

    27

    27

    1.51.5

    1.5

    1.5

    2.5x82ea2.5x77ea

    2.5x74ea

    2.5x71ea

    6.06.0

    6.0

    6.0

    122135

    145

    153

    31.441.3

    51.6

    58.8

    * C.C : Circular Compacted, SEG : Segmental Compacted

    * Fault Current Capacity(63kA/1sec)

    Dia.

    of

    Wire[mm]

    3.13.5

    3.7

    3.9

    8

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    19/42

    EHV XLPE Cable

    Design and Construction of XLPE Cable380/400kV Single Core Cable

    [Insulated Wires, Copper Wire Shield & Lead Sheath Type]

    [Copper Wire Shield & Aluminum-laminated Tape Type]

    Construction: Copper Conductor with Insulated Wires / XLPE Insulation / Copper Wire Shield /

    Lead Sheath / PVC (or PE) Outer Sheath

    * SEG : Segmental Compacted

    * Construction of metallic sheath is subject to change under the fault current condition.

    2000

    2500

    Nominal

    Area[mm]

    Conductor

    Shape

    Approx.Thickness

    of

    Conductor

    Shield[mm]

    SEG

    SEG

    2.0

    2.0

    Thickness

    of

    Insulation

    [mm]

    Approx.Thickness

    of

    Insulation

    Shield[mm]

    No.of

    Wire

    [mm]

    Thickness

    of

    Jacket

    [mm]

    Overall

    Dia.

    [mm]

    Approx.Weight

    (kg / m)

    27

    27

    1.5

    1.5

    2.54x84ea

    2.54x79ea

    6.0

    6.0

    152

    160

    55

    61

    Dia.of

    Wire

    [mm]

    4.0

    4.0

    Construction : Copper Conductor with Insulated Wires / XLPE Insulation / Copper Wire Shield /

    Lead Sheath / PVC (or PE) Outer Sheath

    * SEG : Segmental Compacted

    2000

    2500

    Nominal

    Area

    [mm]

    Conductor

    Shape

    Approx.

    Thickness

    ofConductor

    Shield[mm]

    SEG

    SEG

    2.0

    2.0

    Thickness

    ofInsulation

    [mm]

    Approx.

    Thickness

    ofInsulation

    Shield[mm]

    No.

    of

    Wire

    [mm]

    Thickness

    ofJacket

    [mm]

    OverallDia.

    [mm]

    Approx.

    Weight

    (kg / m)

    30

    30

    1.5

    1.5

    2.6x66ea

    2.6x66ea

    6.0

    6.0

    151

    156

    35

    40

    Dia.

    of

    Wire

    [mm]

    4.0

    4.0

    500kV Single Core Cable

    19

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    20/42

    Manufacturing

    ManufacturingManufacturing Process

    Inner Semi-Conductive PE

    Insulation XLPE

    Outer Semi-Conductive PE

    Wire

    Drawing

    Wire

    Stranding

    Copper or Aluminum Rod

    Segmental

    Circular or Compact Circular

    Taping

    Extrusion Dry Curing

    Simultaneous Process

    Taping

    Conductor

    AssemblingConductor Binder

    SemiConductive Tape

    SemiConductive Tape

    Leads Alloy

    Sheath

    Leads Screw

    Extrusion

    Jacket

    Extrusion

    Wire

    Shield

    Wiring

    Machine

    Jacket

    Extrusion

    Jacket

    Extrusion

    Copper Wire

    Aluminum-Foil

    PE or PVC

    Lead Alloy

    Flooding Compound

    PE or PVC

    Aluminum

    Press

    Corrugated

    Aluminum Sheath

    Aluminum

    Flooding Compound

    PE or PVC

    Test &

    Delivery

    Flow Chart of Manufacturing Process

    0

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    21/42

    Manufacturing

    ManufacturingVCV Line

    Vertical Type Continuous Vulcanizing Equipment

    In case of extra high voltage cable, the insulation thickness is so thick that centers of the conductor and the

    insulation was not coincided each other when catenary type vulcanizing system was adopted. Due to the

    considerable eccentricity of the insulated core, the insulation thickness should be thicker than the electrically

    required value.

    Our facility of vulcanizing process is installed in vertical in the tower of height of approximately 125m. The

    insulation is extruded on the highest place of the tower and passed through the vertical tube for vulcanizing and

    cooling purposes. Since the pass line of the insulated core is vertical, strengthen core is exposed to uniform

    gravity force through its cross-section that no eccentricity can be occurred. By adopting this method, the insulation

    thickness can be reduced remarkably and nowadays, and the extruded thermosetting insulated cables are enough

    competitive to conventional cables.

    Metering Capstan

    Conductor Preheater

    Extruder(3 Layer Triple Common Extrusion)

    N2Gas

    Heating Zone

    ConductorAccumulator

    Pay-off

    CoolingZone

    N2 Gas Tank

    N2Gas HeatExchanger

    Reversing Wheel Water Water Tank

    End SealTurn Wheel

    Take-up

    TensioningCaterpillar

    21

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    22/42

    Manufacturing

    ManufacturingCDCC System

    Completely Dry Curing and Cooling Vulcanizing Method

    We adopt CDCC system for vulcanizing XLPE insulation that is a continuous vulcanizing and dry curing system

    using nitrogen gas. This CDCC system has been recently developed to produce extra high voltage XLPE cables and

    it shows excellent function to reduce faults and imperfections in the insulation.

    In this system, extruded thermosetting compounds are cured in the curing tube by thermal radiation through inert

    nitrogen gas, therefore there is no opportunity that the compounds can absorb any moisture during vulcanizing

    process. The insulated core may be cooled by water in the lower part of the tube, but to obtain better quality in the

    absence of moisture, generally cooled by convection and radiation in a nitrogen gas atmosphere.

    This system is being wholly controlled by computer so that manufacturing conditions and temperatures are

    controlled perfectly. These mean that the quality of the insulation is uniform throughout the cross-section and thelength. All of the process of this system is perfectly protected from outer atmosphere to prevent the insulation

    compounds and the insulated core from any contact with moistures, dust, contaminated air, etc.

    2

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    23/42

    Manufacturing

    ManufacturingAdvantage of CDCC

    Compared with the case of steam curing cable in which a large

    amount of water due to the saturated steam remains in the

    insulation, for CDCC cable, only 100 to 200ppm moisture isdetected in insulation. The water content during curing process

    is shown in Table 1.

    Sample Dry Steam

    Wt(%) 0.018 0.29

    The exteremly small amount of residual water in dry cured

    insulation minimize micorovoids. The example of comparison of

    voids in insulation during curing process is shown in Table 2.

    0

    4

    Curing Method Dry1~3m 4~5m 5~10m 10m over

    Voids Cure

    Steam Cure

    120

    >2,000

    3

    ~300

    0

    77

    Both AC and impulse breakdown strength of insulation by

    CDCC system have been remarkably improved compared with

    that by steam curing process. Fig.2 shows the properties.

    : SCP-CV

    : CDCC

    ACImpulse

    ProbabilityofBreakdown[%]

    Mean Electronical Stress [kV/mm]

    23

    Water Content

    Microvoids

    Electrical Strength

    Table 2. Example of Voids in XLPE Cable

    Table 1. Example of Comparison of Water Content in XLPE Cable

    Fig. 2 AC and Impulse Voltage Breakdown Characteristic

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    24/42

    Manufacturing

    ManufacturingQuality Assurance & Test Requirements

    Extra high voltage cables are the most important cable because they are generally adopted to massive

    power transmission system. Therefore the quality of the cable shall be not only tested for finishedcable products but also controlled during the whole manufacturing processes. All the materials and

    manufacturing processes are stringently controlled, tested and reported according to quality standards.

    Drum test and type test are performed on completed cables. Drum test is done for every length of cables by

    measuring conductor resistance, capacitance, power factor, partial discharge, etc.

    Electrical quality assurance for D/M length test program is done for sampled cable, generally one out of ten lengths

    by measuring impulse breakdown, long-time AC withstand voltage, power factor, partial discharge, etc. Testing

    procedure is one of the important process and every necessary test equipments and devices are installed, such

    as 3600kV impulse generator, 600kV AC testing transformer, schering bridge, 1200kV dielectric breakdown tester

    and shield room.

    Test Item Requirements

    Routine Test

    Type Test

    (Sequence Test)

    Conductor Resistance

    AC Voltage Withstand

    Insulation Resistance

    Capacitance

    Power Factor

    Partial Discharge

    Bending Test

    Partial Discharge Test

    Tan & Measurement

    Heating Cycle Voltage Test

    Impulse Withstand Test

    Power Frequency Voltage Test

    Not exceed the specified value

    2.5U0for 30 min

    Not less than specified value (:2.5 x 1015cm at 20C)

    Not exceed the specified value by more than 8%

    Not more than 0.1% at U0

    Step 1:1.75U0for 10 sec

    Step 2:Not more than 10pC at 1.5U0

    The diameter of the test cylinder : 25(d+D)+5%

    D : measured external diameter of the cable in mm

    d : measured diameter of the conductor in mm

    The sensitivity being 5pC or less

    The magnitude of the discharge at 1.5U0shall not exceed 5pC.

    Not exceed the value 10x 10 -4

    The cycle of heating and cooling shall be carried out 20 times.

    BIL/+10 times

    At 2.5U0for 15 min

    U0 is the rated power-frequency voltage between conductor and earth or metallic screen.

    Standard : IEC 60840 & IEC 62067

    Partialdischarge Test Equipment High Voltage Test Transformer Control Room Test terminal

    4

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    25/42

    Engineering

    EngineeringSystem Design and Engineering Work

    Cable System DesignMost of the extra high voltage cable projects include not only the manufacturing and supply of cables

    and accessories but also cable system design, civil works, cable laying, erection works, site testing and

    commissioning. A cable system should be designed to meet the users requirements in various respects in

    technology, economy, and stability. The design flow of cable system is shown in Chart 1.

    Determining Cable Size

    The selection of conductor size depends on various system and installation conditions. The system conditionsconsist of required current ratings, rated system voltages, system frequency, short-circuit current and its duration,

    and so on. For the maximum current ratings, there are continuous current and emergency current. For the rated

    system voltages, there are nominal voltage, highest voltage, and basic impulse insulation voltage. The installation

    conditions consist of cable laying arrangements, laying methods, laying depth, soil thermal resistivity, ambient

    temperatures, other heat sources, and so on. For the cable laying arrangements, there are flat formation, trefoil

    formation and distances between phases and circuits. For the laying methods, there are directburial laying, in-

    duct laying, in-air laying and others.

    Determining Sheath Bonding MethedCable sheaths are grounded by various methods. A solid bonding method presents the simplest solution. But the

    grounded sheaths produce large cable losses and, in turn, it largely reduces the power capacity of cable system.

    Special bonding methods are applied to reduce the cable losses. A single-point bonding method is applied in caseof short route and less then two joints (see Figure 1), and a cross bonding method is applied in case of long route

    and many joints (see Figure 2). But these methods produce standing sheath-induced voltages, while the cable

    system shall be designed not to exceed the required maximum sheath voltage.

    Determining Cable SpanSince cable products are produced at a certain length, cable jointing is required at a long cable route. Cable drum

    lengths and number of joints are determined generally on the various terms, cable manufacturing, transportation

    of drum, cable laying, cable system design and so on. In general, the followings are the most important terms to

    determine the maximum cable drum length.

    25

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    26/42

    Engineering

    EngineeringSystem Design and Engineering Work

    Review on User's

    Requirement

    Route Survey

    Collecting Design

    Data

    Determining Sheath

    Bonding Method

    Selecting Cable

    Accessories

    Calculating System

    Performance Data

    Stady-state

    Current Rating

    Emergency

    Current Rating

    Short-Circuit

    Current Rating

    Manufacturing

    Capability

    Transportation

    in one Drum

    Sheath Bonding

    Limits

    Cable Pulling

    Tension

    Determining

    Cable SpanSchematic Line

    Diagram

    Determining

    Cable Size

    Fixing Cable

    System

    Chart 1.

    1. Single Point Bonding SystemThis system is adopted for short length of the single core cable,

    generally without any joint, or circuit extension portion in addition to

    cross-bonding system. In this case, induced voltage on the metal layer

    cannot be diminished, therefore the system can be used, provided the

    induced voltage is less than dangerous level approximately 65V.

    [V]

    Limit ied Voltage Induced Sheath Voltage

    Section Length

    Bonding Leads

    Solid Bond Link Box

    Cab le Conductor Cab le Meta ll ic Sheath

    Cable Sealing End

    Link Box

    With SVL's

    Sheath

    VoltageLimiters [SVL's]

    2. Cross-Bonding SystemThis system is generally adopted for single core cable circuit having

    two or more joints. In the system, metallic layer of a cable is electrically

    separated(insulated) and connected to other cable's metallic layer at

    ends of every three section of the circuit, and then it will be connected

    to the another cable's layer. In the first section of the circuit, induced

    voltage is increased in proportion to cable length, but in the next section,

    it is decreased first time and increased again because induced voltagesfrom two otherphase is mixed together in this section. In same reason,

    induced voltage at the end of this three section circuit becomes almost

    zero level remaining small amount of residual voltage due to unbalance

    of the joint section, etc.

    [V] Limited Voltage

    Minor Section Minor Section Minor SectionMajor Section

    Induced Sheath Voltage

    Bonding & Grounding Cable Cable ConductorCable Metallic SheathInsulated Joint

    Normal Joint

    Link Plate

    Solid BondLink Box

    Concentric Bonding LeadCross Bond Link Box

    Sheath Voltage Limiter

    6

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    27/42

    Engineering

    EngineeringInstallation

    TAIHAN has many achievements and excellent techniques related to turnkey-base projects. The turnkey-base

    projects include the installation and engineering services as well as the supply of cable system. The quality of the

    cable system at the site depends mainly on cable laying work, and jointing and terminating works. TAIHAN has

    most qualified engineers and workers who are skillful and experienced in carrying out the installation works. Also

    TAIHAN has much experience on various cable laying methods. The followings are generally applied as a cable

    laying method.

    Direct in the GroundThis method is shown in Fig.3, and is employed in following cases;

    1) Where road is narrow so the construction of conduit under the road not permitted.2) Where the number of cables is few and nofuture increase is expected.

    3) Where the road digging is easy.

    Underground Duct or TunnelThis method is shown in Fig. 4, 5, and is employed in following cases;

    1) The case of main underground transmission line where the number of cables are many or expected to be

    increased in near future.

    2) The case of hard pavement or where hard pavement will be constructed in future.

    3) Where digging is difficult due to heavy traffic.

    Special LayingIn case cables are installed in special places where there are bridges or railways, special laying methods areemployed as follows;

    1) When a cable crosses a river or canal, cables are attached to the bridge. If there is no suitable bridge in the

    neighborhood, an exclusive bridge should be built or a method of submarine laying should be adopted. As long as

    the strength and space of the bridge permits, it is best to attach the cables to the bridge. Whether it is better to

    build an exclusive bridge or to lay submarine cable depends on the cost and difficulty of construction.

    2) In case of crossing a railway, there are two methods; one is digging through the railway bed, and the other is

    piercing from the side of the railway by using an excavator, when the cable crosses many tracks like a surface

    from railroad or suburban railway, digging the railway bed is usually adopted. Except for the above case, piercing

    by using an excavator is adopted.

    27

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    28/42

    Engineering

    EngineeringInstallation

    Fig 3. Direct Burial

    Fig. 4 Cable Laying at Duct

    Fig. 5 Cable Laying at Tunnel

    telephone

    tensionmeter

    pu l l ingwire

    pulling eyeroller orcaterpillar

    caterpillar

    power cable for caterpillar

    cable drum

    operator

    telephone

    controlpanel

    caterpillar cable drum

    Manhole

    cable

    power cable for caterpillar

    pullingeye

    Duct

    winchcar

    Manhole

    tensionmeter

    control panel

    caterpillarcable drum

    Manhole

    power cable for caterpillar

    cable

    telephone

    pullingeye

    Tunnel

    caterpillar or roller

    Manhole

    8

    operator

    trough, if necessary

    operator

    pulling wire

    pulling wire

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    29/42

    Accessories

    [FRP Case]

    AccessoriesPre-Molded Joint

    29

    [Copper Case with Coffin Box]

    No. Description Material

    1

    2

    3

    4

    5

    6

    7

    Conductor Sleeve

    Corona Shield

    PMJ Unit

    Outer Case

    Insulating Flange

    Coffin Box

    Filling Compound

    Copper

    Aluminum

    Silicone Rubber

    Copper

    P.E

    F.R.P

    Polyurethane

    Rated voltage L1

    66kV~69kV

    110kV~161kV

    220kV~275kV

    330kV~400kV

    500kV

    1150

    1350

    1800

    2000

    2000

    L2 D1 H

    1650

    2300

    2500

    2750

    2750

    190

    255

    315

    360

    400

    420

    540

    600

    660

    680

    No. Description Material

    1

    2

    34

    5

    6

    Conductor Sleeve

    Corona Shield

    PMJ UnitOuter Case

    Earthing Sleeve

    Filling Compound

    Copper

    Aluminum

    Silicone RubberF.R.P

    Copper

    Polyurethane

    H

    310

    370

    Rated voltage L

    110kV~161kV

    220kV~275kV

    1400

    1800

    L2

    L1

    D1H

    L

    H

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    30/42

    Accessories

    H

    D

    Rated

    Voltage

    Creepage Distance

    [mm]

    66kV~69kV

    110kV~161kV

    220kV~275kV

    330kV~400kV

    500kV

    Max.5215

    Max.8300

    Max.12600

    Max.23100

    Max.24800

    D

    [mm]

    Max.355

    Max.355

    Max.600

    Max.780

    Max.780

    H[mm]

    Max. 1890

    Max. 2650

    Max. 4250

    Max. 6250

    Max. 7750

    No. Description

    1

    2

    3

    4

    5

    6

    7

    Conductor Sleeve

    Stress Relief Cone

    Hollow Insulator

    Compound

    Sealing Unit

    Post Insulator

    Lower Metal Case

    Material

    Copper

    Silicone Rubber

    Polymeric or Porcelain

    Polybutene Oil

    Silicone Rubber

    Porcelain

    Aluminum

    H

    D

    [Prefablicated Type]

    RatedVoltage

    Creepage Distance[mm]

    110kV~161kV

    220kV~275kV

    Max.8300

    Max.8800

    D[mm]

    Max.355

    Max.560

    H[mm]

    Max. 2650

    Max. 2750

    No. Description

    1

    2

    3

    4

    5

    6

    7

    8

    Conductor Sleeve

    Stress Relief Cone

    Hollow Insulator

    Compound

    Epoxy Support

    Post Insulator

    Lower Metal Case

    Compression Ring

    Material

    Copper

    EPR

    Polymeric or Porcelain

    Silicone Oil

    Epoxy

    Porcelain

    Aluminum or Copper

    Stainless Steel

    AccessoriesOutdoor Termination

    [Slip-on Type]

    0

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    31/42

    Accessories

    No. Description

    1

    2

    3

    4

    5

    6

    Upper Metal

    Epoxy Bushing

    Conductor Sleeve

    Stress Relief Cone

    Compression Ring

    Lower Metal Case

    Material

    Aluminum

    Epoxy

    Copper

    EPR

    Stainless Steel

    Copper or Aluminum

    * All dimensions are complying with IEC60859 and IEC62271-209

    RatedVoltage

    66kV~88kV

    110kV~161kV

    220kV~275kV

    330kV~400kV

    D

    [mm]

    110

    110

    200

    250

    H[mm]

    583

    757

    960

    1400

    D

    [mm]

    110

    110

    140

    140

    H[mm]

    310

    470

    620

    960

    Fluid Filled type Dry Type

    [Fluid Filled Type] [Dry Type]

    H

    DD

    H

    [Slip-on Type]

    D

    [mm]

    110

    140

    140

    Rated

    Voltage

    110kV~161kV

    220kV~275kV

    330kV~500kV

    H

    [mm]

    757

    960

    1400

    Material

    Aluminum

    Epoxy

    Copper

    Silicone Rubber

    Polybutene Oil

    Silicone Rubber

    Copper or Aluminum

    No. Description

    1

    2

    3

    4

    5

    6

    7

    Upper Metal

    Epoxy Bushing

    Conductor Sleeve

    Stress Relief Cone

    Compound

    Sealing Unit

    Lower Metal Case

    * All dimensions are complying with IEC60859 and IEC62271-209

    H

    D

    AccessoriesSF

    6Gas Insulated Termination

    [Prefablicated Type]

    31

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    32/42

    Accessories

    AccessoriesCOMPOSITE HOLLOW BUSHING

    H

    OD

    H

    OD

    Taihan has been developing and producing composite hollow bushing which consists of FRP tube and

    silicone rubber sheds to withstand various environmental conditions. The advantage of compositebushing over traditional porcelain bushing has been proven and is well known and accepted.

    ADVANTAGES

    Reduced Risk for transport and assembly (no broken sheds)

    Explosion Safety for personnel and installation

    Excellent Seismic Performance

    High Insulating Performance in highly polluted environment

    APPLICATIONS

    Cable Terminations Circuit Breakers

    Instrument Transformers

    Lightning arrester

    [Normal flange] [Cap flange]

    RatedVoltage

    110kV~161kV

    220kV~275kV

    52806720

    8150

    Max.9100

    D

    [mm]

    260260

    260

    370

    H[mm]

    16762060

    2444

    2535

    Creepage Distance[mm]

    14951879

    2263

    Max.2308

    Arcing Distance[mm]

    [mm]

    378378

    378

    505

    * Other creepage distances are on request

    2

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    33/42

    Accessories

    AccessoriesGIS EPOXY INSULATOR

    Taihan has been manufacturing several kinds of cast epoxy insulators which are using in GIS systems.

    With our extensive knowledge regarding material technology with advanced process engineering

    skills, we have been developed and produced GIS insulator upto 800kV grade.

    VACUUM CASTING TECHNOLOGY

    Void-free Insulation

    Excellent adhesion to metallic parts

    Net shape casting

    PRODUCT

    Insulation Spacer

    Tri-post Insulator

    Earthing Terminal

    Insulation Supporter

    [420kV 1P Spacer]

    [550kV 1P Spacer]

    [170kV 3P Spacer]

    [420kV Tri-Post Insulator ]

    33

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    34/42

    Diagnosis System

    Diagnosis SystemCable Diagnosis System

    DTS menuDetect cable fault symptom, and find out fault location

    as analyzing distributed temperature.

    Alarm works for exceeding limitation of cable surface temperature, conductor temperature,conductor temperature 0deviation, temperature differences between joints, peaks, and cable

    permitted load. Malfunction of DTS are also sensed based on DTS temperature data.

    Section can be set by operator to monitor whole cables separating them into several sections.These sections are usually divided depending on joints, but its flexible. Information for recent alarm

    is shown on the section table.

    Historymenu supports operators to inquire temperature and alarm history data. Operator can

    choose cable surface temperature, conductor temperature, peaks as inquiry objects, and they are

    displayed on the chart. Alarm data are listed up at a table. The chart and table can be printed as an

    image and a table respectively, and they can be exported as an excel file.

    1. Total Monitoring System (TMS)As a cable Total Monitoring System, TMS consists of three parts functionally, DTS system which can

    monitor distributed temperature of the cable, cable model data which includes thermal resistance

    and capacitance, and cable current value acquisition module. Menus of TMS are DCR, DTS, Alarm,

    Section, Setup, and History.

    DCR menuIncrease efficiency of cable operation as calculating dynamic rating.How long current can be sustained from now on?

    This cable can afford 2302[A] up to 8Hr.

    8Hr

    Input arbitrary current value, then

    affordable time is calculated.

    Input arbitrary time, then affordable

    current value is calculated.

    Cable rating can be calculated

    Just with temperature data.

    Cable system configuration

    Data Summary Table

    1) Location of Bottle Necks2) Cable Surface Temperature

    3) Cable Conductor Temperature

    4) Spatial Peak & Time Interval

    Peak

    Bott le neck is the spot which

    has the highest cable surface

    temperature decides the cable

    rating, and it is updated every 1

    hour for last 24 hours

    4

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    35/42

    Diagnosis System

    Pulse Generator Spectrum Analyzer HFCT Sensor Foil SensorAmplifier Unit

    2. PD (Partial Discharge) MeasurementPartial discharge is an incomplete breakdown of insulation and a kind of discharging phenomenon,

    which is generated by or at air-gap of solid insulator, gas foam of liquid insulator, contacting surfaces

    of different insulating materials and peaks on metallic surface. It is generated by the reason that as

    the permittivity of gas area is lower than that of solid or liquid, electric field is concentrated, and thuselectric discharges occur in the gas due to the low dielectric strength of the gas.

    1) Measurement MethodImpress an AC voltage of commercial cycle to a conductor to detect partial discharge of the insulator

    between the conductor and a shielding layer. And measure the starting electric charge and frequency

    of the partial discharge.

    2) Analyzing Measurements

    ICM System

    (1) Main Components of PD Devices

    Acquisition Unit / System Controller

    (2) On-site PD Detection on EHV Cable (Insulation Joint)

    (3) Patterns of PD Result

    Void Discharge of Insulator Internal Discharge from a Joint Electric Tree of XLPE Cable

    35

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    36/42

    Diagnosis System

    Diagnosis SystemCable Diagnosis System

    (1) Main Components of PD Devices

    PD Base System

    Media ConverterPD Base Impedance Matching Box System Controller

    Direct Coupler Calibrator Amplifier Unit Synchronization Sensor

    (3) Patterns of PD Result

    A. Resonant Test Set Induced Disturbance

    B. Corona in HV Connections

    C. Correlation Disturbance due to the Switching Devices of the

    AC Resonant Test Set

    D. HF Noise due to External Sources

    E. PD from a Joint

    6

    (2)On-site PD Detection on EHV Cable (Termination)

    3) Available Equipment

    Equipment Manufacturer Purchasing Date Diagnosis Performances

    ICMSystem

    PD BaseSystem

    Power Diagnostix(Germany)

    TECHIMP(Italy)

    2003/08

    2005/07

    KEPCO (345kV Yeongseo -Yeongdeungpo T/L, 154kV Seongdong - Heungin T/L,154KV Daejeon - Shinheung T/L, etc.) Commercial Clients (Many sites including Korea LNG Gas)

    KEPCO (Many works including 154kV underground T/L in Central P/O of SeoulElectric Power) Commercial Clients (Many sites including 230kV Singapore, 154kV ChangwonSpecialty Steel, 154kV Honam Thermal Power Plant and345kV Yangyang Pumping-up Power Plant)

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    37/42

    Diagnosis System

    3. Thermal infrared imaging measurement

    1) Objects of Measurement

    2) Measurement Cycle

    3) Analyzing Measurement

    4) Available Equipment

    Equipment Manufacturer Purchasing Date Diagnosis Performances

    ThermaCAM

    QuickView

    FLIR System(Sweden)

    2004/01

    KEPCO (345kV Yeongseo-Yeongdeungpo T/L, 154kVSeongdong - Heungin T/L, 154KvDaejeon -Shinheung T/L, etc.) Consigned patrol(Yeongseo,Seongdong and Daejeon ElectricPower) Commercial Clients (Many sitesincluding Korea LNG Gas, ChangwonSpecialty Steel, Yangyang Pumping-up Power Plant)

    Circuit Measurement

    Thermal Infrared Imaging Measurement

    4. Other Inspection & Measurements of XLPE Cable

    Inspection & Measurement Items Method of Evaluation

    Inspecting manhole/electric powerculvert (tray) and cable (on-line)

    Inspecting metallic support & joint box (on-line)

    Inspecting cable head (on-line)

    Sheath Megger Test / withstandvoltage test (10kV) (off-line)

    Inspecting fire detecting facility (online)

    Partial discharge measurement(on-line / off-line)

    Thermal infrared imaging measurement(on-line)

    Locking Device of Exits, Installation state of ladder & guard rail, leakage & crack inelectric power culvert, cleaning state of electric power culvert, prevention of disasterin electric power culvert, snake deformation of cable, prevention of disaster for cable,state of curvature, disorder of fire shielding plate

    Deformation of metallic support, measuring current of metallic sheath, measuringtemperature of joint box, measuring insulation resistance of anti-corrosion layerof cable, disorder of Cross-Bonding wire, water-tightness of anti-corrosion layerprotecting device

    Measuring temperature of overheated place for conductor joining part / PG clamp/ lightening arrester joining part, measur ing insula tion resi stance, Dobble Test

    Joint places / cable

    Fixed temperature detector, firefighting device, etc.

    Joint places

    Measuring image temperature with Thermal-vision/follow-up

    37

    * Inspection of power transmission facilities can be performed in on-line or off-line state according to the properties of a facility.

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    38/42

    Appendix

    APPENDIXCertification

    The outstanding quality of TAIHAN EHV XLPE cables are verified by internationally accredited certification institutes.

    Type Test Certificates over 132kV

    1

    23

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    24

    25

    No. BIL (kV)Description of Cable & Accessories InstituteDate

    Cable, Premolded Straight Joint, Outdoor Termination

    CableCable

    Cable

    Cable

    Cable, Outdoor Termination

    Cable, NJ, IJ, Outdoor Termination

    Cable, NJ, IJ, Outdoor Termination

    Cable, PIJ, GIS & Outdoor Termination

    Cable, NJ, IJ, Outdoor Termination

    Cable, IJ, GIS Termination

    Cable, PNJ, PIJ, GIS & Outdoor Termination

    Cable, NJ, GIS & Outdoor Termination

    Cable, PNJ, PIJ, GIS & Outdoor Termination

    Cable, NJ, GIS & Outdoor Termination

    Cable, PNJ, PIJ, GIS & Outdoor Termination

    Cable, NJ, IJ, GIS & Outdoor Termination

    Cable

    Cable, IJ, GIS & Outdoor Termination

    Cable, PIJ, GIS & Outdoor Termination

    Cable, PMIJ, PMNJ, GIS & Outdoor Termination(Polymer type)

    Cable, PIJ, GIS & Outdoor Termination

    Cable

    Cable, NJ

    Cable

    SpecificationVoltage Grade

    KEMA

    KERIKERI

    KERI

    Crown Agents

    Crown Agents

    KERI

    KERI

    KEMA

    KERI

    Taihan

    KEMA

    Taihan

    KERI

    Taihan

    KERI

    KEMA

    CTL(USA)

    SGS

    KERI

    SGS

    KEMA

    Taihan

    KERI

    Taihan

    May-86

    May-86Aug-86

    Aug-88

    May-95

    May-96

    May-97

    Sep-97

    Jun-98

    Sep-99

    Aug-00

    Aug-00

    Mar-01

    Jun-01

    Dec-03

    Mar-04

    Jan-05

    Feb-05

    Apr-05

    Jul-05

    Apr-05

    Sep-05

    Oct-05

    Oct-05

    Nov-06

    IEC 502

    KEPCOKEPCO

    KEPCO

    IEC 840

    IEC 840

    KEPCO

    KEPCO

    IEC 840

    KEPCO

    IEC 62067

    IEC 60840

    IEC 60840

    KEPCOIEC 62067IEC 60840

    KEPCOIEC 62067

    IEC 62067

    AEIC CS7-93

    IEC 62067

    KEPCOIEC 62067

    KEPCOIEC 60840

    IEC 60840

    IEC 60840

    IEC 60840

    IEC 61901

    132kV 630mm (CU)

    154kV 600mm (CU)154kV 1200mm (CU)

    154kV 2000mm (CU)

    132kV 1000mm (CU)

    132kV 630mm (AL)

    154kV 600mm (CU)

    154kV 2000mm (CU)

    230kV 2000mm (CU)

    154kV 2000mm (CU)

    132kV 630mm (CU)

    132kV 1200mm (CU)

    132kV 800mm (AL)

    345kV 2000mm (CU)

    132kV 630mm (CU)

    345kV 600mm (CU)

    400kV 2000mm (CU)

    138kV 1000mm (CU)

    230kV 2000mm (CU)

    345kV 1200mm (CU)

    154kV 2500mm (CU)with fiber optic cable

    132kV 1000mm (CU)

    132kV 1000mm (CU)

    132kV 630mm (CU)

    69kV 2500mm (CU)

    650

    750750

    750

    650

    650

    750

    750

    1050

    750

    650

    650

    650

    1300

    650

    1300

    1425

    650

    1050

    1300

    750

    650

    650

    650

    -

    8

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    39/42

    Appendix

    * KERI : Korea Electrotechnology Research Institute

    * KEPCO : Korea Electricity Power Company( The National Power Utility in Korea)

    * POSCO : Pohang Steel Corporation

    System Certificates

    No. Description of Cable & Accessories Institute Date Specification

    1

    2

    Design and manufacture of high voltage

    insulators and cable joint accessories

    Design and manufacture of electric cable

    * SGS-ICS : Systems & Services Certification

    39

    26

    27

    28

    29

    30

    31

    32

    33

    34

    35

    36

    37

    38

    39

    40

    41

    42

    43

    44

    45

    46

    47

    48

    49

    50

    51

    52

    53

    54

    55

    56

    57`

    No. BIL (kV)Description of Cable & Accessories InstituteDate

    Cable

    Cable, PMJ, GIS & Outdoor Termination

    Cable, NJ, Outdoor Termination, CONNEX Cabletermination system (Size 4, Size 5S)

    Cable, Cross Bonding Joint, Outdoor Termination

    Cable, NJ, Straight Through Cross Bonking Joint

    Cable, Straight Through Cross Bonking Joint, GIS &Outdoor Termination

    PMJ

    Cable, NJ, GIS & Outdoor Termination

    Cable, IJ

    Cable

    Cable, PMIJ, PMNJ, PIJ, PNJ, GIS & Outdoor Termination

    Cable, NJ, GIS Termination

    Cable, NJ, GIS Termination

    Cable, NJ, PMIJ, PMNJ, GIS & Outdoor Termination

    Cable, PMIJ, Outdoor Termination

    Cable, PNJ, GIS & Outdoor Termination

    Cable, IJ, GIS & Outdoor Termination

    Cable, PMIJ, GIS & Outdoor Termination, OilImmersed Transformer Termination

    Cable, PMIJ, PMNJ, GIS & Outdoor Termination

    Cable, NJ, GIS & Outdoor Termination

    Cable, PMJ, Outdoor Termination

    Cable, NJ, GIS & Outdoor Termination, Cross-Bonding Link Box, Solid Link Box with Arrester,Solid Bonding Link Box without SVL's

    Cable, IJ, NJ, GIS & Outdoor Termination

    Cable, GIS & Outdoor Termination, Pre-Molded TypeCross Bonding Joint, Transformer Sealing End

    Cable, PMJ, GIS & Outdoor Termination

    Cable, IJ, NJ, GIS & Outdoor Termination

    Cable, IJ, NJ, GIS & Outdoor Termination

    Cable, NJ, Outdoor Termination

    Cable, Outdoor Termination

    Cable, PIJ, Outdoor Termination, SF6 SwitchagearSealing end (Oil Type, Dry Type), TransformerTermination (Oil Type, Dry Type)

    Cable, GIS Termination, Pre-mold type straightinsulated joint

    Cable

    SpecificationVoltage Grade

    Taihan

    KEMA

    Taihan

    Taihan

    KEMA

    KEMA

    KEMA

    KEMA

    Taihan

    KEMA

    KERI

    Taihan

    Taihan

    KERI

    KERI

    KERI

    KEMA

    KEMA

    KERI

    KEMA

    Taihan

    KEMA

    KEMA

    Taihan

    Taihan

    KEMA

    KEMA

    Taihan

    Taihan

    Taihan

    Taihan

    Taihan

    Oct-05

    Sep-06

    Nov-06

    Jan-07

    Jan-07

    May-07

    Dec-07

    Dec-07

    Jul-07

    Oct-07

    Jul-08

    Mar-08

    May-08

    Jun-09

    Jun-09

    Jun-09

    Dec-09

    Jul-09

    Feb-10

    Jan-10

    Mar-10

    Apr-10

    May-10

    Dec-10

    Jul-10

    Mar-11

    Nov-10

    Jan-11

    Feb-11

    May-11

    Jul-11

    Oct-11

    IEC 60840

    IEC 62067

    IEC 60840

    IEC 60840

    IEC 60840

    IEC 60840

    IEC 62067

    IEC 62067

    IEC 60840

    IEC 60840

    KEPCO

    IEC 60840

    IEC 60840

    IEC 60840

    IEC 60840

    IEC 60840

    IEC 62027

    IEC 60840

    KEPCO

    IEC 62027

    IEC 60840

    IEC 60840

    IEC 62067

    AEIC CS9-06IEC 62067

    IEC 62067

    IEC 62067

    IEC 62067

    IEC 62067

    IEC 60840

    IEC 60840

    IEC 60840

    IEC 60840

    132kV 1000mm (CU)

    220kV 2500mm (CU)

    66kV 500mm (CU)

    132kV 1200mm (CU)

    132kV 630mm (CU)

    132kV 1200mm (CU)

    400kV

    380kV 2500mm (CU)

    66kV 1000mm (CU)

    132kV 630mm (CU)

    345kV 2500mm(CU) withfiber optic cable

    132kV 1600mm (CU)

    132kV 300mm (CU)

    132kV 2500mm (CU)

    275kV 2500mm (CU)

    220kV 2000mm (CU)

    400kV 2500mm (Enamel - CU)

    132kV 1000mm

    154kV 400mm (CU) -17t

    400kV 2500mm (Enamel - CU)

    132kV 1200 & 2000mm

    132kV 1200mm

    230kV 3500mm

    220kV 1200mm

    230kV 2000mm

    220kV1200mm (AL)

    500kV 2500mm

    230kV 1400mm (AL)

    138kV 1200mm

    132kV 630mm

    66kV 1000mm

    132kV 630mm

    IEC 60840

    IEC 62067

    IEC 60840

    IEC 60840

    IEC 60840

    IEC 60840

    IEC 62067

    IEC 62067

    IEC 60840

    IEC 60840

    KEPCO

    IEC 60840

    IEC 60840

    IEC 60840

    IEC 60840

    IEC 60840

    IEC 62027

    IEC 60840

    KEPCO

    IEC 62027

    IEC 60840

    IEC 60840

    IEC 62067

    AEIC CS9-06IEC 62067

    IEC 62067

    IEC 62067

    IEC 62067

    IEC 62067

    IEC 60840

    IEC 60840

    IEC 60840

    IEC 60840

    SGS-ICS

    SGS-ICS

    2001.02

    2003.03

    ISO 14001

    ISO 9001

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    40/42

    Appendix

    DubaiRepresentative Office

    Flat No.1204, Al Safa Tower, Sheikh Zayed Road, P.O.Box 117561, Dubai, UAETEL :+971-4-331-7233 FAX :+971-4-331-7322E-mail :[email protected], [email protected]

    Singapore Branch Office

    150 Kampong Ampat #07-04 KA Centre Singapore 368324,Republic of SingaporeTEL :+65-6842-5069 FAX :+65-6842-5076E-mail :[email protected]

    Newzealand Branch Office

    Suite 2, Level 11, 48 Em ily Place, Auckland PO Box 105895,Auckland City, Auckland 1143TEL :+64-9-368-7703 FAX :+64-9 368-7704E-mail:[email protected]

    Riyadh Branch Office

    Office No.613, Al Rossais Commercial CenterOlaya Road, P.O.Box 300201, Riyadh 11372, Kingdom of SaudiArabiaTEL :+966-1-419-0227 FAX :+966-1-419-0262E-mail :[email protected]

    Qatar Branch Office

    Duhail Road Near College of North Atlantic P.O.Box :18740 - Doha QatarTEL :+974-421-3851E-mail:[email protected]

    Kuwait Branch Office

    Sabah al Salem, block No.4, Street No.31 House No.7, State of KuwaitTEL :+965-2552-8642 FAX :+965-2552-1498E-mail :[email protected]

    Kuala Lumpur Branch Office

    No.9, 2nd Floor, Jalan Pandan Pr ima 1 Dataran Pandan Prima 55100 Kuala Lumpur, MalaysiaTEL :+60-3-9018-9113/9115 FAX :+60-3-9200-1136E-mail :[email protected]

    Overseas Branch Office

    Overseas Subsidiaries

    Subsidiary Company / Branch office

    Hong Kong TGH (Taihan Global Holdings, Ltd.)

    No.1808, 18F, Tower 2, Admiralty Center,18 Harcourt Road, Admiralty, Hong Kong

    Australia Branch Office

    Suite 2, Level 13, 80 Mount Street, North Sydney, NSW 2060, AustraliaTEL :61-2-9460-3600 FAX :61-2-9954-4354E MAIL:[email protected]

    Argentina Branch Office

    Suipacha Suites, Room 909 Suipacha 1235TEL :+54-911-6413-7430 FAX :54-911-6413-4694E MAIL :[email protected]

    Venezuela Branch Office

    Avenida Principal Los Chorros de mila Centro Epresarial Villa Los ChorrosPiso4 Oficina 404 Merida, VenezuelaTEL :+58-274-414-1627E-mail :[email protected], [email protected]

    South Africa Malesela Taihan Electric Cable Pty., Ltd. (M-TEC)

    Steel Road Peacehaven Vereeniging 1930 Gauteng, South Afr icaTEL :+27-16-450-8200 FAX :+27-16-450-8202E-mail :[email protected] :www.m-tec.co.za

    D.R.Congo STANDARD TELECOM

    158, Avenue de la Democratie(Ex- Huilerie) Commune de la Gombe, Kinshasa, D.R.CongoTEL :+243-1511-0007FAX :+243-1511-1100E-mail :[email protected] :www.st.cd

    Vietnam Taihan Sacom Cable Co., Ltd (TSC)

    7th Floor, 71-73 Dien Bien Phu, phuong 15, Binh Thanh District, VietnamTEL : +84-8-518-0786FAX :+84-8-518-0785E-mail :[email protected] :www.tsc.vn

    USA Taihan USA (Taihan Electric USA., Ltd.)

    LandMark Building, 99 Tulip Avenue, Suite#106, Floral Park, NY 11001, USATEL : +1-516-355-5600FAX :+1-516-355-5601E-mail :[email protected]

    Qatar

    New Zealand

    APPENDIXGlobal Networks

    0

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    41/42

    Appendix 41

  • 8/10/2019 1204_EHV+XLPE%28 %29.pdf

    42/42