14-07-14_typevenfpapt-2-sf

1
awing is the copyright of "Planquadrat India Pvt. nd must not be retained, copied or used without ove consultant's consent. scale from this drawing. indicated otherwise all dimensions are in ters. ensions to be verified on site and approved by the er prior to construction. awing should be read in conjunction with the cations, other relevant architectural, structural, nical and electrical drawings and all relevant s of the specifications. CTIONS am depths and slab thickness dimensions refer ctural drawings.

Upload: mnc19

Post on 20-Jul-2016

212 views

Category:

Documents


0 download

DESCRIPTION

project

TRANSCRIPT

MEP & FIRE FITHTING

STRUCTURAL

ARCHITECTS

Ralys Consulting EngineersIst Flr, 2245/1,Banashankari II stg,Bangalore - 560 070.Telefax: +91 80 41510757email : [email protected] : www.ralys.com

TITLE

TYPICAL 2, 4, 6, 8, 10, 12 & 14th

FLOOR PLANS

CONSULTANTS

PROJECT

CLIENT

1. This drawing is the copyright of "Planquadrat India Pvt.

Ltd." and must not be retained, copied or used without

the above consultant's consent.

2. Do not scale from this drawing.

3. Unless indicated otherwise all dimensions are in

millimeters.

4. All dimensions to be verified on site and approved by the

engineer prior to construction.

5. This drawing should be read in conjunction with the

specifications, other relevant architectural, structural,

mechanical and electrical drawings and all relevant

sections of the specifications.

NOTES

INSTRUCTIONS

1. For beam depths and slab thickness dimensions refer

to structural drawings.

2. For duct details refer MEP drawings.

LEGEND

Concrete blocks

DRAWN CHECKED APPROVEDDESIGNED

SCALE DATE REVISIONSIZE

Sheet #Drg #

Md US SS VK

1:75 A1 10/01/2014 02

PQI-1104-A-205 1 of 1

MANOHAR CONSULTANTS#2, Ist Flr, 4th main, 12th cross,Wilson Garden, Bangalore - 560 027.Phone : +91 80 22272762Mob : 9880034611email : [email protected]

MANUCONS

2 27.03.2014 Duct Size Changes US VK

1 20.03.2014 Changes in beams US VK

# Date DESCRIPTION CKD APD

REVISIONS

DOORS

# TYPE WIDTH HEIGHT SILL

1 D2 1000 2100 -

2 D3 900 2100 -

3 D4 750 2100 -

4 FD4 750 1500 600

5 D5 900 1500 600

6 FD 1000 1500 600

7 A2 1730 2400 -

8 A3 1830 2400 -

9 SD1 3900 2400 -

10 SD2 2900 2400 -

11 SD3 2600 2400 -

12 SD4 2250 2400 -

13 SD5 1700 2400 -

14 SD6 1625 2400 -

VENTILATORS

# TYPE WIDTH HEIGHT LNTL

1 V1 825 1500 2400

2 V2 750 1500 2400

3 V3 715 1500 2400

4 V4 600 1500 2400

5 V5 500 1500 2400

6 V7 800 1500 2400

7 V8 625 1500 2400

DRAWING REFERENCES

#

Description

#

Description

300-302 Sections 505 Lift Details

400-402 Elevations 508 Toilet Details

500

Staircase Drawing

700 Duct Details

503

Joinery Details

504

Balcony Railing Details

WINDOWS

# TYPE WIDTH HEIGHT LNTL

1 W1 1650 2250 2400

2 W2 1700 2250 2400

3 W4 825 2250 2400

4 W5 1000 2250 2400

5 W6 1000 1350 2400

Porotherm blocks

# Name TYPE

1 D1 PHE

2 D2 PHE

3 D3 PHE

4 D4 PHE

5 D5 PHE

6 D6 PHE

7 D7 PHE

# Name TYPE

8 D8 GC

9 D9 ECS

10 D10 PHE

11 D11 PHE

12 D12 PHE

13 D13 PHE

14 D14 FHC

DUCTS

ECS - Electrical & Communication

Shaft

EFS

WB

GC

# ASL

F2F

Height(m)

Ht (mm)

2nd Floor 111.75 6.2 9200

4th Floor 117.95 6.2 15400

6th Floor 124.15 6.2 21600

8th Floor 130.35 6.2 27800

# ASL

F2F

Height(m)

Ht (mm)

10th Floor 136.55 6.2 34000

12th Floor 142.75 6.2 40200

14th Floor 148.95 6.2 46400

16th Floor 155.15 - 52600

# Name TYPE

15 D15 PHE

16 D16 PHE

17 D17 PHE

18 D18 FHC

19 D19 PHE

20 D20 PHE

21 D21 PHE

22 D22 STP EXH

TYPICAL FLOOR LEVELS

Floor# Name

Length

Width

6th B 4030 1750

8th D 1755 1750

8th E 3375 1750

4 & 14th K 2605 1750

Floor# Name

Length

Width

10th M 3165 1750

14th H 2375 1750

6 & 12th I 2605 1750

12th A 3165 1750

BALCONY DETAILS

- Electrical Shaft

- Waste Bin

- Garbage Chute

change the door position as shown

align the wall to the beam andmake the width 150mm