1409567-01-30-01 1409491-01-30-01 - tejidos roca alaska/cads rsl.pdf · germany expertise:...

4
Germany Expertise: 1409567-01-30-01 1409491-01-30-01 Member of PFI Group Datum / Date: 2014-10-21 Dr. Knauer Orderer: Order: Test Ítem: Tejidos Roca SL Polígono Ind San Augustin ES - 30430 Cehegin (Murcia) Spain Examination of materials Your letter/Fax/Email dated 2014-10-09 Received: 2014-10-13 2014-10-09 Synthetic fabrics A art. Alaska, col. rojo, Peso 145 GSM, Ancho 170 cms B art. Alaska, col. marrón, Peso 145 GSM, Ancho 170 cms C art. Alaska col. negro, Peso 145, GSM Ancho 170 cms, no. 1 D art. Alaska col. negro, Peso 145, GSM Ancho 170 cms, no. 2 Test results: Description of the procedures, shortcuts and detailed results of the tested samples on the following pages. Parameter Alkylphenoles, NPEO+NP+OP+OPEO Chlorinated Phenoles, PCP+TeCP isomer (sum) +TriCP ¡somer (sum) Dimethylfumarate, DMF Disperse Dyes allergenic Carcinogenic Dyes Formaldehyde Textiles Triclosan Prohibited aromatic amines, AZO Tinorganic compounds, TBT+MBT+DBT+TPhT+DOT Unit mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg Result* SEP <0.5 <0.1 n.n. n.n. <10 <50 <20 SEP Material MP MP MP MP MP MP MP MP MP Rating 0 0 0 0 0 Oa 0 0 0 Ratina: 0 = Sample meets the CADS requirements Oa = Sample meets the CADS requirements, result below the quantification limit 1 = Further test necessary 2 = Sample failed the CADS requirements - = not tested or material not available Die Prüfergebnisse beziehen sich ausschliefilich auf die Prüfgegenstánde. Ohne schriftliche Genehmigung des PFI darf die Expertise nicht auszugsweise verwendet werden Restliches Untersuchungsmaterial wird nach 10 Wochen vernichtet In Einzelfállen kann eine Untervergabe an andere geeignete Prüflaboratorien erfolgen Ein Verzeichnis der akkredltierten Prüfverfahren und unsere geltenden Allgemeinen Gescháftsbedingungen kónnen auf unserer Internetseite eingesehen werden und werden Ihnen auf Anfrage gerne zugesandt / Test results so/e/y refer to the ítems tested Extracts of the expertise may not be used without written permission by PFI Remaining materials will be destroyed after 10 weeks In individual cases, tests can be carried out by qualified subcontracting laboratoríes. A list ofaccredited test methods and our applying general terms and conditions are available on our website and will be sent to you on request Prüf- und Forschungsinstitut Pirmasens e.V. • Marie-Curie-Strasse 19 D-66953 Pirmasens www.pfi-pirmasens.de [email protected] Seite / page 1 von / of4 PFI-FB-PB01-02

Upload: trinhkhanh

Post on 13-Sep-2018

231 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1409567-01-30-01 1409491-01-30-01 - Tejidos Roca alaska/CADS RSL.pdf · Germany Expertise: 1409567-01-30-01 1409491-01-30-01 Member of PFI Group Datum / Date: 2014-10-21 Dr. Knauer

Germany

Expertise: 1409567-01-30-011409491-01-30-01

Member of PFI Group

Datum / Date: 2014-10-21Dr. Knauer

Orderer:

Order:

Test Ítem:

Tejidos Roca SL

Polígono Ind San Augustin ES - 30430 Cehegin (Murcia) Spain

Examination of materialsYour letter/Fax/Email dated 2014-10-09 Received: 2014-10-13

2014-10-09

Synthetic fabricsA art. Alaska, col. rojo, Peso 145 GSM, Ancho 170 cmsB art. Alaska, col. marrón, Peso 145 GSM, Ancho 170 cmsC art. Alaska col. negro, Peso 145, GSM Ancho 170 cms, no. 1D art. Alaska col. negro, Peso 145, GSM Ancho 170 cms, no. 2

Test results:Description of the procedures, shortcuts and detailed results of the tested samples on the following pages.

Parameter

Alkylphenoles, NPEO+NP+OP+OPEO

Chlorinated Phenoles,PCP+TeCP isomer (sum)+TriCP ¡somer (sum)

Dimethylfumarate, DMF

Disperse Dyes allergenic

Carcinogenic Dyes

Formaldehyde Textiles

Triclosan

Prohibited aromatic amines, AZO

Tinorganic compounds,TBT+MBT+DBT+TPhT+DOT

Unit

mg/kg

mg/kg

mg/kg

mg/kg

mg/kg

mg/kg

mg/kg

mg/kg

Result*

SEP

<0.5

<0.1

n.n.

n.n.

<10

<50

<20

SEP

Material

MP

MP

MP

MP

MP

MP

MP

MP

MP

Rating

0

0

0

0

0

Oa

0

0

0

Ratina:0 = Sample meets the CADS requirementsOa = Sample meets the CADS requirements, result below the quantification limit1 = Further test necessary2 = Sample failed the CADS requirements- = not tested or material not available

Die Prüfergebnisse beziehen sich ausschliefilich auf die Prüfgegenstánde. Ohne schriftliche Genehmigung des PFI darf die Expertise nicht auszugsweise verwendet werden RestlichesUntersuchungsmaterial wird nach 10 Wochen vernichtet In Einzelfállen kann eine Untervergabe an andere geeignete Prüflaboratorien erfolgen Ein Verzeichnis der akkredltierten Prüfverfahrenund unsere geltenden Allgemeinen Gescháftsbedingungen kónnen auf unserer Internetseite eingesehen werden und werden Ihnen auf Anfrage gerne zugesandt / Test results so/e/y refer to theítems tested Extracts of the expertise may not be used without written permission by PFI Remaining materials will be destroyed after 10 weeks In individual cases, tests can be carried out byqualified subcontracting laboratoríes. A list ofaccredited test methods and our applying general terms and conditions are available on our website and will be sent to you on request

Prüf- und Forschungsinstitut Pirmasens e.V. • Marie-Curie-Strasse 19 • D-66953 Pirmasens • www.pfi-pirmasens.de • [email protected]

Seite / page 1 von / of4PFI-FB-PB01-02

Page 2: 1409567-01-30-01 1409491-01-30-01 - Tejidos Roca alaska/CADS RSL.pdf · Germany Expertise: 1409567-01-30-01 1409491-01-30-01 Member of PFI Group Datum / Date: 2014-10-21 Dr. Knauer

Germany

Expertise: 1409567-01-30-011409491-01-30-01

Member of PFI Group

Datum / Date: 2014-10-21Dr. Knauer

Remarks:n.n = not detectable (n.d.), MP = mixed materials, EP = single material test* Explicit given results for mixed materials (MP) are the total contení of the sample. For valúes with sign ofinequality the content of each material of the mixed sample is below the given valué

Dr. M. Knauer(Abteilungsleiíung / Deparímení Managemení)

Dr. K. Schulíe(Insíiíuísleiíung / Managing Director)

Die Prüfergebnisse beziehen sich ausschlieíilich auf die Prüfgegenstánde Ohne schriftliche Genehmigung des PFI darf die Expertise nicht auszugsweise verwendet werden RestlichesUntersuchungsmaterial wird nach 10 Wochen vernichtet In Einzelfállen kann eine Untervergabe an andere geeignete Prüflaboratorien erfolgen Ein Verzeichnis der akkred/tierten Prüfverfahrenund unsere geltenden Allgemeinen Gescháftsbedingungen kónnen auf unserer Internetseite eingesehen werden und werden Ihnen auf Anfrage gerne zugesandt / Test results so/e/y refer to theítems tested Extracts of the expertise may not be used without written permission by PFI. Remaining materials will be destroyed after 10 weeks. In individual cases, tests can be carried out byqualified subcontracting laboratoríes. A list ofaccredited test methods and our applying general terms and conditions are available on our website and will be sent to you on request.

Prüf- und Forschungsinstitut Pirmasens e.V. • Marie-Curie-Strasse 19 • D-66953 Pirmasens • www.pfi-pirmasens.de • [email protected]

Seite / page 2 von / of 4PFI-FB-PB01-02

Page 3: 1409567-01-30-01 1409491-01-30-01 - Tejidos Roca alaska/CADS RSL.pdf · Germany Expertise: 1409567-01-30-01 1409491-01-30-01 Member of PFI Group Datum / Date: 2014-10-21 Dr. Knauer

Germany

Expertise: 1409567-01-30-011409491-01-30-01

Member of PFI Group

Datum / Date: 2014-10-21Dr. Knauer

Appendix to expertise 1409567-01-30-01Single results of the tested samples

Parameter

Prohibited aromatic amines, AZO

Dimethylfumarate, DMF

Dimethylfumarate, DMF

Triclosan

Chlorinated Phenoles,PCP+TeCP isomer (sum)+TriCP isomer (sum)

Tinorganic compounds,TBT+MBT+DBT+TPhT+DOT

Alkylphenoles,NPEO+NP+OP+OPEO

Disperse Dyes allergenic

Carcinogenic Dyes

Formaldehyde Textiles

Formaldehyde Textiles

Material

1:(A),(B),(C),(D)

1:(A),(B)

2: (C) = (D)

1:(A),(B),(C) = (D)

1:(A), (B),(C) = (D)

1:(A),(B),(C) = (D)

1:(A),(B),(C) = (D)

1:(A),(B),(C),(D)

1:(A), (B),(C),(D)

1:(A),(B)

2: (C) = (D)

Result*

<20

<0.1

<0.1

<50

<0.5

< 0.025 TBT< 1.0MBT + DBT< 1 .0 TPhT + DOT

< 100 NP< 100 OP48 NPEO< 100 OPEO

n.n.

n.n.

< 10

< 10

Unit

mg/kg

mg/kg

mg/kg

mg/kg

mg/kg

mg/kg

mg/kg

mg/kg

mg/kg

mg/kg

Rating

0

0

0

0

0

0

0

0

0

0

0

ShortcutABADAPPBEBSBSLDFDKNDSLDSMEBFELFFLFFMFLFMFMLFOFZ

Englishshoe heelcoveringapplicationfacinginsoleinsole leatherheel patchpress buttonsock leathersock materialpipingfurheel lining leatherheel lining materiallining leatherlining materiallining material tonguefoilfelt

ShortcutGPGZHKHZKHKKKKLKNKOKRKVLALBLEMHKMSNADNETNIE

Englishwhole productelasticheel capwoodno direct skin contactplástic compactclampbuttoncorkcollarvelerotonguelabelleatherwith direct skin contactmetal loopseam coveringmeshrivet

ShortcutNOPOLOMPNRPPPTRARGRlRSVRSV-ADSBSBLSCSchlSESEPSFSK

Englishnepupper leatherupper materialtesting not relevantpaperboardtypical of productborderringstrapzipperzipper coveringshoe laceshoe lace leatherupperloopsolé insertionsee detailed resultsinspection windowsolé wedge

ShortcutSMSNSOSOSOLSPSRSTSWsyn.TSTX

JVKVLVSZBZMZSZWM

Englishfoambuckleoutsoleeyeletsolé leatherfrontsolé weltstoppernew woolsyntheticbagtextiletoe capclosurereinforcingfancy tapeintermedíate materialtoe spreadernot enough material

Die Prüfergebnisse beziehen sich ausschliefilich auf die Prüfgegenstánde. Ohne schriftliche Genehmigung des PFI darf die Expertise nicht auszugsweise verwendet werden RestlichesUntersuchungsmaterial wird nach 10 Wochen vernichtet. In Einzelfállen kann eine Untervergabe an andere geeignete Prüflaboratorien erfolgen E/n Verzeíchnís der akkreditierten Prüfverfahrenund unsere geltenden Allgemeinen Gescháftsbedingungen kónnen auf unserer Internetseite eingesehen werden und werden Ihnen auf Anfrage gerne zugesandt / Tesf results so/e/y refer to theitems tested. Extracts of the expertise may not be used without written permission by PFI. Remaining materials will be destroyed after 10 weeks In individual cases, tests can be carríed out byqualified subcontracting laboratories A list of accredited test methods and our appiying general terms and conditions are available on our website and will be sent to you on request

Prüf- und Forschungsinstitut Pirmasens e.V. • Marie-Curie-Strasse 19 • D-66953 Pirmasens • www.pfi-pirmasens.de • [email protected]

Seite / page 3 von / of 4PFI-FB-PB01-02

Page 4: 1409567-01-30-01 1409491-01-30-01 - Tejidos Roca alaska/CADS RSL.pdf · Germany Expertise: 1409567-01-30-01 1409491-01-30-01 Member of PFI Group Datum / Date: 2014-10-21 Dr. Knauer

Member of PFI Group(••••••••••IMI

Germany

Expertise: 1409567-01-30-01 Datum / Date: 2014-10-211409491-01-30-01 Dr. Knauer

Examination Proceda re:Test methods are part of the laboratory accreditation (D-PL-14150-01-00)

Shortened form: Alkylphenoles, NPEO+NP+OP+OPEODetermination of Nonvlphenole (NP). Nonvlphenol ethoxviates (NPEO). Octvlphenole (OP) and Octvlphenol ethoxviates(OPEO)

Alkylphenoles: using GC-MS after solvent extraction with methanol

Alkylphenol ethoxylates: after draft standard DIN EN ISO 18218-1:2012-09 for leather, after draftstandard DIN EN ISO 18254:2014-06 for textiles

Shortened form: Chlorinated Phenoles, PCP+TeCP isomer (sum)+TriCP isomer (sum)Determination of Pentachlorophenol. Tetra- and Trichlorophenole-lsomers

Draft standard DIN EN ISO 17070:2012-08

Shortened form: Disperse Oyes allergenicDetection of allergenic Disperse Dves

DIN 54231:2005-11 and BVL B 82.02-10:2007-03, Draft standard DIN EN ISO 16373-2:2012-05

Shortened form: Carcinogenic OyesDetection of Carcinoqenic Dves

according to DIN 54231:2005-11 and BVL B 82.02-10:2007-03; draft standard DIN EN ISO 16373-2:2012-05 anddraft standard DIN EN ISO 16373-3:2012-11

Shortened form: Formaldehyde TextilesDetermination of free and hvdrolvtic Formaldehvde in textile

DIN EN ISO 14184-1:2011-12 and BVL B 82.02-1:1985-06

Shortened form: Prohibited aromatic amines, AZODetection of prohibited aromatic amines from Azo-dves

Draft standard DIÑEN ISO 17234-1:2012-10 and DIN EN ISO 17234-2:2011-06 and BVL B 82.02-3(V): 2004-06 for leatherDIN EN 14362-1:2012-04 and BVL B 82.02-2:2004-06 for textiles and BVL B 82.02-4:2004-6 for polyesterDIN EN 14362-3:2012-09 and BVL B 82.02-9:2006-09 / BVL B 82.02-9:2006-09 revision:2008-03 (4-Amino-azobenzene)for textiles and polyester

Shortened form: Tinorganic compounds, TBT+MBT+DBT+TPhT+DOTDetermination of Tributvltin (TBT). Monobutyltin (MBT). Dibutvltin (DBT). Triphenyltin (TPhT) and Dioctyltin (DOT)

TR DIN EN ISO/TS 16179; DIN SPEC 91179:2012-12

Test methods are not part of the laboratory accreditation (D-PL-14150-01-00)

Shortened form: Dimethylfumarate, DMFDetermination of Dimethylfumarate

TR DIN EN ISO/TS 16186; DIN SPEC 53280:2012-12

Shortened form: TriclosanDetermination of Biocide finish for materials

using GC-MS after extraction with organic solventDie Prüfergebnisse beziehen sich ausschlieftlich auf die Prüfgegenstánde. Ohne schriftliche Genehmigung des PFI darf die Expertise nicht auszugsweise verwendet werden. RestlichesUntersuchungsmaterial wird nach 10 Wochen vernichtet. In Einzelfállen kann eine Untervergabe an andere geeignete Prüflaboratorien erfolgen E/n Verzeicnnis der akkreditierten Prüfverfahrenund unsere geltenden Allgemeinen Gescháftsbedingungen kónnen auf unserer Internetseite eingesehen werden und werden Ihnen auf Anfrage gerne zugesandt. / Test results so/e/y refer to theítems tested. Extracts of the expertise may not be used without wrítten permission by PFI Remaining materials will be destroyed after 10 weeks. In individual cases, tests can be carneó out byqualified subcontracting laboratoríes. A list ofaccredited test methods and our applying general terms and conditions are available on our website and will be sent to you on request.

Prüf- und Forschungsinstitut Pirmasens e.V. • Marie-Curie-Strasse 19 • D-66953 Pirmasens • www.pfi-pirmasens.de • [email protected]

Seite / page 4 von / of4PFI-FB-PB01-02