165 brumley avenue northeast, suite 2001concord, north
TRANSCRIPT
2
UL U419
EXTEND 5/8" FIRE CODE GYPSUM BOARD TO
UNDERSIDE OF ROOF STRUCTURE AND SEAL.
COORDINATE STUD SIZE WITH STRUCTURAL DRAWINGS.
1 HR. RATED METAL PARTITION WALL
1
NON-RATED
METAL PARTITION WALL
VARIES
FL. LINE
VARIES
FL. LINE
CONT. FIRE CAULK EACH
SIDE
UNDERSIDE OF STRUCTURE
TOP OF VERTICAL. STUDS 1"
FROM UNDERSIDE OF
STRUCTURE NESTED IN TOP
TRACK WITH EXTENDED
RETURN LEGS TO ALLOW FOR
STRUCTURAL DEFLECTION
TOP TRACK. SEE
STRUCTURAL FOR NUMBER
AND SPACING
R-19 SOUND ATTENUATION
BATT INSULATION AT
EXTERIOR S
6" MTL STUDS WITH 1
LAYER 5/8" GYPSUM
BOARD ON BOTH SIDES
BOTTOM TRACK
BASE AS SCHEDULED
CONCRETE SLAB
CONT. FIRE CAULK EACH
SIDE
UNDERSIDE OF STRUCTURE
TOP OF VERTICAL. STUDS 1"
FROM UNDERSIDE OF
STRUCTURE NESTED IN TOP
TRACK WITH EXTENDED
RETURN LEGS TO ALLOW FOR
STRUCTURAL DEFLECTION
TOP TRACK. SEE
STRUCTURAL FOR NUMBER
AND SPACING
BLOCKING AS REQUIRED
R-19 OR R-19 SOUND
ATTENUATION BATT
INSULATION
4" OR 6" MTL STUDS WITH
1 LAYER 5/8" TYPE "X" G.W.B.
ON BOTH SIDES
BOTTOM TRACK
BASE AS SCHEDULED
EXISTING FLOOR.
1 HR.
UL U419
A
B
A
B
A1.0
3
6'-6
"
FLOOR MOUNTED TOILET
PARTITIONS, (TA-7), TYP.
PNT
???
A
B
A
B
MANAGER
201
201A
RECEPTION
200
200A
CONFERENCE
203
203A
WORKSTATIONS
202
ASSISTANT
MANAGER
204
LIBRARY
205
204A
205B
BREAK
ROOM
206
205A
206A
206B
SF
01
SF02
CORRIDOR
208
CORRIDOR
208
CORRIDOR
208
207A
8 R
IS
ER
S A
T 6
" E
AC
H
8 R
IS
ER
S A
T 6
" E
AC
H
8 R
IS
ER
S A
T 6
" E
AC
H
11'-6" 4'-0" 12'-4"
ALIGN WALL W/
WINDOW EDGE
GENERAL NOTE: ALL
FURNITURE SHOWN
BY OTHERS
8'-1"
209A
CLO
207
16'-10"
11'-6"
EX
IS
TIN
G
EXISTING STEEL
COLUMNS (TYP)
SF
03
FUTURE BUSINESS
TENANT SPACE
209
GENERAL NOTE: FUTURE TENANT SPACE NOT IN
SCOPE OF WORK OTHER THAN WHAT IS SHOWN
6'-0"
2'-0"
37'-10"
12'-0"
2'-6"
1
E
13'-5"
1
1
2
2
2
2
2
4'-0"
2
2
2
2
2
2
2
2
2
1 1 1
1
1
1 1 1
1
1
1
1
1
EX
IS
TIN
G
EX
IS
TIN
GE
XIS
TIN
G
EXISTING EXISTING EXISTING EXISTING
E
X
I
S
T
I
N
G
E
X
I
S
T
I
N
G
E
X
IS
T
IN
G
ALIGN WALL W/
WINDOW EDGE
NEW DOORS ADDED FOR
FUTURE TENANT SPACE
1 1 1
1
1
E
CORRIDOR
208
A1.0
4
FUTURE STORAGE
TENANT SPACE
210
GENERAL NOTE: FUTURE TENANT SPACE NOT IN
SCOPE OF WORK OTHER THAN WHAT IS SHOWN
210A
WOMEN
211
MEN
212
EX
IS
TIN
GE
XIS
TIN
GE
XIS
TIN
GE
XIS
TIN
G
208A
NE
W S
HE
LV
IN
G (B
Y O
TH
ER
S)
NE
W S
HE
LV
IN
G (B
Y O
TH
ER
S)
NE
W S
HE
LV
IN
G (B
Y O
TH
ER
S)
NEW DOORS ADDED FOR
FUTURE TENANT SPACE
E
2
A1.0
212A
211A
℄
6'-8 1/2"
℄
℄
A1.0
VCS OFFICE -
FLOOR PLAN,
ENLARGED
RESTROOMS,
ELEVATION
1
RENOVATED SECOND FLOOR OFFICE PLAN
3/16"=1'-0"
3800 Arco Corporate Drive
Suite 125, Charlotte, NC 28273
704-377-9799
www.studiofusionpa.com
PROJECT NUMBER : 18-092
ISSUED: 12-17-2018
REVISION:
CA
NN
ON
M
ILL 17
- V
CS
O
FF
IC
E U
PF
IT
-
165 B
rum
ley A
venue N
ortheast, S
uite 2001
Concord, N
orth C
arolina 28025
CERT: NO.
51150
S
T
U
D
I
O
FUS
IO
N
,
P
A
.
C
H
A
R
L
O
TTE
,
N
C
.
2
ENLARGED RESTROOMS
1/4"=1'-0"
5
PROPOSED EXTERIOR ELEVATION - SOUTH
1/8"=1'-0"
3
RESTROOMS ELEVATION
1/4"=1'-0"
4
WALL TYPES
N.T.S.