17nov themesession2 _seai_marren
Post on 21-Oct-2014
413 views
DESCRIPTION
TRANSCRIPT
Q3 2010 CES Energy Group Overview
Global Forum
Q3 2010 CES Energy Group Overview
Agenda
1. CES Energy i. Company overview
ii. Supply side reduction
iii. Demand side reduction
iv. Energy concession contracting
v. Data centre example
Q3 2010 CES Energy Group Overview
Mission Statement
To deliver renewable and conventional high efficiency on-site electrical, cooling and heat
generation solutions.
To supply energy efficient products and services providing substantial financial and CO2 savings to
our customers
Q3 2010 CES Energy Group Overview
UK: CHP, District Heating, Cooling and on site Energy Systems: 2012 Olympics site @ Sentrum Data Centres, INIS Stratford, Ardmore Oval Road, IBM,
IRL: HVAC, CHP, Tri-Generation and on site Energy Systems for AIB, Boston Scientific, Citi, A&L Goodbody, Data Electronics JTI plc, Hilton Hotel, IBM….
Australia: Offices in Sydney and Melbourne.Multiple On Site Energy Centres in large buildings, Mirvac, Sydney University, Corporate Express, Miller Street.....
Middle East: 2010 Commenced Tendering for on Site Energy Projects in Saudi Arabia, MENA
Group Activity
Q3 2010 CES Energy Group Overview
Agenda
1. CES Energy i. Company overview
ii. Supply side reductioniii. Demand side reduction
iv. Energy concession contracting
v. Data centre example
Q3 2010 CES Energy Group Overview
Combined Heat and Power (CHP)Combined Heat and Power (CHP) is the use of a single process to simultaneously generate
both electricity and useful heat. It is one of the most common forms of energy recycling
Q3 2010 CES Energy Group Overview
Tri-Generation• Tri-Generation is the simultaneous production of electricity, heat and cooling from a
single fuel input • The "waste heat" by-product that results from power generation is harnessed, thus
increasing the overall efficiency of the system• A Tri-Generation system consists of a CHP engine/turbine and an Absorption Chiller
Q3 2010 CES Energy Group Overview
Why Tri-generation?• Tri-Generation offers a use for waste heat on a site when there is no heat demand• Below is a load profile of a typical commercial building showing high summer cooling
demand
jan feb mar apr may jun jul aug sep oct nov dec
0
500
1000
1500
2000
2500
3000
3500
Load (kW)
Month
CHILLING
HEATING
ELECTRICAL
Q3 2010 CES Energy Group Overview
Biomass CHPBiomass CHP is the use of a biomass fuel to simultaneously generate both electricity and
useful heat in a renewable process
Q3 2010 CES Energy Group Overview
15/10/2009 CES Energy Group Overview
Sample Target sites
Q3 2010 CES Energy Group Overview
CES Energy CITI Solution
Plant Capacities• Peak Electrical: 2,000kW• Peak Heating: 2,544kW
Client benefits:• 10% energy cost reduction• Carbon reduction of 2,500 tonnes• CES remote monitor and carry out all
operation and maintenance on system
‘ESCo’ type agreement signed 2007
Case Studies
Q3 2010 CES Energy Group Overview
101 Miller Street, Sydney
Plant Capacities• Peak Electrical: 3,000kW• Peak Cooling: 2,500kW
Benefits to client• No 5 green star building rating• Energy cost savings: 10%• CO2 saving: 10,000 tonnes p.a.
Case Studies
Q3 2010 CES Energy Group Overview
CES Energy Boston Scientific Solution
Plant Capacities• Peak Electrical: 1,166 kW• Peak Heating: 1,260 kW
Benefits:• Over €500K per annual savings• Containerised CHP Solution, easy
integration• CES remote monitor and carry out all
operation and maintenance on system• Carbon reduction 1,500 tonnes
Case Studies
Q3 2010 CES Energy Group Overview
Mixed development in Saudi Arabia
Plant Capacities• Peak Electrical: 38MVA• Peak Cooling: 70 MW
Benefits to client• Energy cost savings• Conventional design 79MVA, reduced
to 38MVA, Capex savings• CO2 saving: 180,000 tonnes p.a.• 25 Year contract
Case Study/Project Reference
Q3 2010 CES Energy Group Overview
Back-Office Site MonitoringCES Energy Site Status
Q3 2010 CES Energy Group Overview
Site Monitoring
Q3 2010 CES Energy Group Overview
Back-Office Control: P&ID
Q3 2010 CES Energy Group Overview
Agenda
1. CES Energy i. Company overview
ii. Supply side reduction
iii. On-Site Power, cooling and heat Generation
iv. Project examples
v. Demand side reductionvi. Energy concession contracting
vii. Data centre example
Q3 2010 CES Energy Group Overview
CES Energy Concession Contracting Engineered energy efficiency
programs Provision of finance for
equipment upgrade programs No up front investment
required Energy Savings finance
improvements Partnership approach to
energy reduction Flexible contracts 3 – 15 years Diverting money already
being spent
Simply press start to reduce your energy costs
Q3 2010 CES Energy Group Overview
Energy Concession Contracting€250M is wasted / year in office buildings in Dublin alone*
Many of the newest buildings are the worst offenders
80% of the buildings we will occupy in 2050 are standing today
In typical office buildings savings of 30 – 40% are achievable
Businesses are experiencing market cost pressures
Energy costs to increase substantially over the next 5 years
Future carbon taxes will further increase the cost of wasted energy
Wasted energy is wasted profits
Q3 2010 CES Energy Group Overview
Energy Concession Contracting
Q3 2010 CES Energy Group Overview
Agenda
1. CES Energy i. Company overview
ii. Supply side reduction
iii. On-Site Power, cooling and heat Generation
iv. Project examples
v. Demand side reduction
vi. Energy concession contracting
vii.Data centre example
Q3 2010 CES Energy Group Overview
The worldwide COThe worldwide CO22-discharge of the data centers is approx. -discharge of the data centers is approx. 62 million tons62 million tons..
(source: Sustainable Partner GmbH)(source: Sustainable Partner GmbH)
Prognosis: The global power demand of all data centers Prognosis: The global power demand of all data centers worldwide raises up about 40 % until 2010.worldwide raises up about 40 % until 2010.(source: Jonathan Koomey/IDC) (source: Jonathan Koomey/IDC)
Is IT the new climate killer?Is IT the new climate killer?
Environment aspects
Q3 2010 CES Energy Group Overview
Energy streams inside the data center
Why is energy efficiency so important?
POWER IN = HEAT OUT
Q3 2010 CES Energy Group Overview
Interior view
Heat exchanger
• extensive Cu/Al-heat exchanger with hydrophyle lamella coating
Filter
• extensive cassette filter F5, installed directly on the cooler
• easy filter exchange from the front
Condensate drain
• Inspection openings for cleaning of the condensate drain
• Aluminium vessel can be removed
deltaclima®
High Efficiency, InnovativeCRAC Units
Q3 2010 CES Energy Group Overview
Common technology
Raised floor
Bare floor
assembly loss
unused space
additional deflection losses
Energy-saving airconditioning systems
bad fans efficiency
small distance to the housing (<1,5*D)
high overpressure on pressure side
Q3 2010 CES Energy Group Overview
Raised floor
Bare floor
New technology
Extended coil surface (+A)
Extended filter surface (+A)
Reduced internal pressure losses (-pINT)
Reduced power consumption (-PW)
clima
deltaclima®
Energy-saving airconditioning systems
Q3 2010 CES Energy Group Overview
The beautiful Cold – Free cooling
• From Met Eireann Data the Temperature in Dublin is at or below 6 °C for 24% of the year
• The temperature in Dublin is at or below 12 °C for 67% of the year
Q3 2010 CES Energy Group Overview
Direct Free Cooling
Q3 2010 CES Energy Group Overview
Data center for automotive industry, Germany1.500 kW
Energy-saving airconditioning systems
Energy-saving with DIRECT FREE COOLING
Q3 2010 CES Energy Group Overview
Energy efficiency is important!
€ 442.188,--/year
€ 249.862,--/year
energy consumption airconditioning datacenter
0
50
100
150
200
250
300
350
400
450
MW
h
Weiss TeleclimaNEDC2MWh 1270 m²
"Traditional Cooling"NEDC1MWh 1270 m²
Q3 2010 CES Energy Group Overview
Physikalische Vorteile der Multi-Kompressortechnik
Kälteleistungsstufen: 0% - 50% - 80% - 100%
1 2
Verdampfer
Kondensator3
Kältetechnik
Q3 2010 CES Energy Group Overview
Compressor 1 Compressor 2 Compressor 3 Total
Cooling Capacity
Input power
Cooling Capacity
Input power
Cooling Capacity
Input power
Cooling Capacity
Input power
COP
kW kW kW kW kW kW kW kW kW/ kW
1st Stage (50%) 27,2 3,7 --- --- --- --- 27,2 3,7 7,4
2nd Stage (80%) 21,4 4,5 21,4 4,5 --- --- 42,8 9 4,8
3rd Stage (100%) 17,7 5,2 17,7 5,2 17,7 5,2 53 15,6 3,4
Reference Data:
•Room: 24°C - 50% RH
•Outside air Temperature: 35°C
•Condensation Temperature: 50 °C
Q3 2010 CES Energy Group Overview
P
Tc
Te
3 2
14
H
3I 2I
P
TcI
4I 1ITeI
H
Carnot Cycle
Tc Kondensationstemperatur [°C]
Te Verdampfungstemperatur [°C]
Kältetechnik
Q3 2010 CES Energy Group Overview
Standard Chillers• R22 Phase Out, may represent a opportunity• Typically 6 to 8 these chillers have a COP=1.4 to
2.5• Newer chillers operating on R134a will be
operating with a COP of 3.2 to 3.6
Q3 2010 CES Energy Group Overview
Chiller Replacement Proposal
Typical 1000kw chiller
Chiller Capacity COPRun
Hours kWh Cost Per kWhRunning
Cost
Existing 1000 2 8760 4380000 €0.11 €481,800
New Chiller 1000 3.2 8760 2737500 €0.11 €301,125
Chiller Mech, Elec & Site Works Finance Years
Capital Cost €103,572 €120,000 3 €74,524
Energy Savings
€180,675
Reactive Maintenance €7,000
Maintenance €5,000
Total -€118,151
Q3 2010 CES Energy Group Overview
Free Cooling Chillers
Chiller Capacity COPRun
Hours kWh Cost Per kWhRunning
Cost
Existing 1000 2 8760 4380000 €0.11 €481,800
Free Cooling 24% 1000 2108 €0.00 €0
Part Cooling 43% 1000 3.2 3802 891093.8 €0.11 €98,020
Electrical Cooling 33% 1000 3.2 2850 667968.8 €0.11 €73,477
Saving €310,303
Chiller Mech, Elec & Site Works Finance Years
Capital Cost €134,643 €120,000 3 €84,881
Energy Savings
€310,303
Reactive Maintenance €7,000
Maintenance €5,000
Total -€237,422
Q3 2010 CES Energy Group Overview
CES Energy Partners
CES Energy has formed alliances with a number of strategic partners
Worldwide turnover of €20 billion and over 400,000 employees
Turnover of €1 billion and over 1,000 professionals skilled in all aspects of project execution and delivery. Responsible for the construction and commissioning of circa 2,000MW power stations in Ireland and UK
State owned company, owns 7% of the land cover of Ireland Turnover €250m, over 1,200 employees
Top 50 ASX listed company involved in gas and oil exploration and production, power generation and energy retailing 140-year history, Almost 4000 employees and more than 3 million customers in Australia, New Zealand and the Pacific
German/Austrian market leader in district heating solutions, manufacturing base in East Germany
Q3 2010 CES Energy Group Overview
THANK THANK YOUYOU