2 of 2 a0 - 40 seven · 2019-06-04 · ch chainage chl channel level ci cast iron c/i corrugated...

2
GPR Scan 416 9.06 9.12 9.15 9.17 9.08 9.06 9.08 8.77 8.83 8.70 8.83 8.92 9.46 9.41 9.46 9.63 9.60 9.46 9.13 9.16 9.31 9.14 9.20 9.08 8.82 NFI 2"PE 2"PE 4"DI 125PE 100DI 2"PE 4"DI 4"DI NFI NFI NFI EOT D=0.90m D=0.80m D=0.75m D=0.90m D=0.80m D=0.75m EOT EOT EOT D=0.60m D=0.35m D=0.20m D=0.30m D=0.90m EOT D=0.45m D=0.35m D=0.35m D=0.40m D=0.20m EOT EOT Silted EOT MH D=0.80m Disused REV. DETAILS BY GRID DATUM SURVEYED BY: DRAWN BY: SCALE: APPROVED BY: SURVEY DATE: REV: DATE CLIENT: PROJECT TITLE: DRAWING TITLE: LEEDS E-Mail: [email protected] Web site: www.40seven.com LONDON 01732 740696 0113 201 9700 Close Circuit Television British Telecom Surface Drainage Combined Drainage Telecommunications Cable Television Foul Drainage Unknown Fibre Optics Gas Water Electricity Ducting Traffic Light System Unknown Route Located By GPR Overhead Electricity Overhead Telecom GPR Image Position SHEET LAYOUT UTILITY LEGEND Transport for London DRAWING NUMBER: SHEET NUMBER: SEDDON CONSTRUCTION LTD PLODDER LANE EDGE FOLD BOLTON BL4 0NN WEST LANE TOPOGRAPHICAL & UTILITY MAPPING SURVEY WEST LANE FORMBY DH / SC NC GJ 1:200 @ A0 02/2019 1678_P 1 of 2 A0 ORDNANCE SURVEY RELATED TO THE OS ACTIVE STATIONS BY GPS OBSERVATIONS ORDNANCE SURVEY RELATED TO THE OS ACTIVE STATIONS BY GPS OBSERVATIONS Unless otherwise stated, all services shown on this plan have been surveyed using approved detectors and the connections between manholes, if not traced, are assumed to be direct. No guarantee can be given that all services have been shown. In ideal conditions the depth accuracies for the underground utilities located is +/- 10% of depth. Where services are shown as 'Taken From Records' on the drawing we are not liable for any loss that may arise due to a lack of accuracy in that guided information. Due to BT's policy we are not permitted to lift their inspection chamber covers. Reference should be made to the methodology used on site as detailed within the latest version of 40SEVEN's Site Procedures for Utility Location Surveys. Excavations in the vicinity of services shown are to be carried out with due diligence (Ref: HS(G)47.) The following text* is an extract from Surveys of Land, Buildings and Utility Surveys at scales of 1:500 and Larger issued by the Royal Institute of Chartered Surveyors December 2014. *Electronic tracing is a reliable method of locating buried services. On heavy, built up sites 85% completeness is probably all that can be expected. *Plan accuracies of the order of + or - 150mm may be achieved but this figure will depend on the depth of the service below ground level. Where similar services run in close proximity, separation may be impossible. Successful tracing of non-metallic pipes may be limited. *Existing record information showing underground services is often incomplete and of doubtful accuracy. It should be regarded only as an indication and cannot be guaranteed. Read in conjunction with existing records. Utility routes and text shown in dark grey are from existing records. Drainage routes with a pipe diameter of 300mm or greater are shown as the pipe width along with continuous line style. For additional copies please contact 40SEVEN. Services plotted outside survey extents should not be considered to be exhaustive. AC Asbestos Cement ACU Air Conditioning Unit AD Assumed Direction AR Assumed Route AV Air Valve BB Belisha Beacon BD Back Drop BdL Bed Level BH Borehole Bk Brick BL Basement Light BO Bollard BR Brick BS Bus Stop BT British Telecom Cover BTB British Telecom Box BW Brick Wall B/W Barbed Wire Fence Cam Camera CAT Catenary Level C/B Close Borded Fence CC Control Cabinet CH Chainage ChL Channel Level CI Cast Iron C/I Corrugated Iron Fence CL Cover Level C/L Chain Link Fence Co Concrete CP Catch Pit CpL Coping Level CrB Crash Barrier CTV Cable TV CUL Culvert CW Concrete Wall DI Ductile Iron dil Dilapidated dis Disused D/S Downstream DSW Dry Stone Wall EB Electricity Box EC Electricity Cover E/F Electric Fence EOT End of Trace EP Electricity Pole ER Earth Rod FC Fuel Cover FFL Finished Floor Level FH Fire Hydrant FO Fibre Optic Cover FS Flag Staff G Gully GPRI Ground Penetrating Radar Inconclusive GV Gas Valve H/R Hand Rail IC Inspection Cover IL Invert Level I/R Iron Rail Fence KO Kerb Outlet LB Letter Box LC Lighting Column LH Lamp Hole LOR Loss Of Reflection LOS Loss Of Signal MB Mooring Bollard M/C Multiple Cables MH Manhole Cover Mkr Marker Post MP Mile Post/Stone NFI No Further Information NM Node Marker NP Name Plate NPV No Pipes Visible OSA Off Survey Area P Post PBM Permanent Bench Mark PE Polyethylene PGM Permanent Ground Marker PL Plastic P/L Palisade Fence PM Parking Meter P/R Post and Rail Fence PU Pump PVC Polyvinylchloride P/W Post and Wire Fence PZ Piezometer RE Rodding Eye Ri Riser RL Rail Level RP Reflector Post RS Road Sign RWP Rain Water Pipe R/W Retaining Wall S Stump SA Survey Abandoned S/A Soakaway SC Speed Camera S/F Safety Fence SI Spun Iron SL Soffit Level SP Sign Post Spr Spring S/R Steel Railings SS Sonde Stops ST Stop Tap Stn Survey Station SV Sluice Valve SVP Soil Vent Pipe SW Stone Wall Tac Tactile Paving TBM Temporary Bench Mark TC Telecom Cover TCB Telephone Call Box TCP Telephone Call Post TFR Taken From Records TH Trial Hole / Pit ThL Threshold Level Tk Tank TOW Top Of Wall TP Telegraph Pole TOS Top of Silt U/S Upstream UTGA Unable to Gain Access UTL Unable to Locate UTR Unable to Raise UTS Unable to Survey UTT Unable to Trace VC Vitrified Clay VDP Vehicle Detector Pads VP Vent Pipe VR Vapour Recovery VTP Vertical Pipe W Water Cover WL Water Level WM Water Meter W/M Wire Mesh Fence WO Water Wash Out WS Window Sample WV Wheel Valve Survey Extents Photo Position * Please Note: Utility routes shown in dark grey & with line type (r) are from existing records. Example: ABBREVIATIONS DISCLAIMER NOTES GPR Ground Anomaly GPR Geological Movement GPR Reinforcement GPR Underground Structure GPR Underground Void Survey Type Quality Level Post- Processing Location Accuracy Supporting Data Horizontal Vertical D Desktop utility Records Search QL-D - Undefined Undefined - C Site Reconnaisance QL-C - Undefined Undefined A segment of utility whose location is demonstrated by visual reference to street furniture, topographical features or evidence of previous street works (reinstatement scar). B Detection QL-B4 No Undefined Undefined A utility segment which is suspected to exist but has not been detected and is therefore shown as an assumed route. QL-B3 No цϱϬϬŵŵ Undefined (No reliable depth measurement possible) Horizontal location only of the utility detected by one of the geophysical techniques used. QL-B3P Yes QL-B2 No цϮϱϬŵŵ Žƌ ϰϬй of detected depth whichever is greater цϰϬй ŽĨ detected depth Horizontal and vertical location of the utility detected by one of the geophysical techniques used. QL-B2P Yes QL-B1 No цϭϱϬŵŵ Žƌ ϭϱй of detected depth whichever is greater цϭϱй ŽĨ detected depth Horizontal and vertical location of the utility detected by one of the geophysical techniques used. QL-B1P Yes A Verification QL-A - цϱϬŵŵ цϮϱŵŵ Horizontal and vertical location of the top and/or bottom of the utility. 1 2

Upload: others

Post on 18-Mar-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 2 of 2 A0 - 40 Seven · 2019-06-04 · CH Chainage ChL Channel Level CI Cast Iron C/I Corrugated Iron Fence CL Cover Level C/L Chain Link Fence Co Concrete CP Catch Pit CpL Coping

GPR Scan 416

9.069.12

9.15

9

.

1

7

9.08

9.06

9.08

8.77

8.83

8.70

8.83

8.92

9

.4

6

9.4

1

9.46

9.63

9.6

0

9.46

9.13

9.16

9.3

1

9.1

4

9.20

9.0

8

8.82

NF

I

2"P

E

2"PE

4"DI

125PE

100D

I

2"PE

4"DI

4"D

I

NF

I

NFI

NFI

EOT

D=0.90m

D=

0.8

0m

D=

0.7

5m

D=0.90m

D=0.80m

D=0.75m

EOT

EOT

E

O

T

D

=

0

.6

0

m

D

=

0

.3

5

m

D=0.20m

D

=

0

.3

0

m

D=

0.9

0m

E

O

T

D

=

0

.

4

5

m

D

=

0

.3

5

m

D=0.35m

D=0.40m

D=0.20m

EOT

E

O

TS

i

l

t

e

d

E

O

T

1

5

0

Ø

MH

D=0.80m

Disused

100Ø

REV. DETAILS BY

GRID DATUM

SURVEYED BY: DRAWN BY:

SCALE:

APPROVED BY:

SURVEY DATE:

REV:

DATE

CLIENT:

PROJECT TITLE:

DRAWING TITLE:

LEEDS

E-Mail: [email protected] Web site: www.40seven.com

LONDON

01732 7406960113 201 9700

Close Circuit Television

British Telecom

Surface Drainage

Combined Drainage

Telecommunications

Cable Television

Foul Drainage

Unknown

Fibre Optics

Gas

Water

Electricity

Ducting

Traffic Light System

Unknown Route Located By GPR

Overhead Electricity

Overhead Telecom

GPR Image Position

SHEET LAYOUT

UTILITY LEGEND

Transport for London

DRAWING NUMBER:

SHEET NUMBER:

SEDDON CONSTRUCTION LTD

PLODDER LANE

EDGE FOLD

BOLTON BL4 0NN

WEST LANE

TOPOGRAPHICAL & UTILITY MAPPING SURVEY

WEST LANE

FORMBY

DH / SC NC GJ

1:200 @ A0 02/2019

1678_P

1 of 2 A0

ORDNANCE SURVEY

RELATED TO THE OS

ACTIVE STATIONS BY

GPS OBSERVATIONS

ORDNANCE SURVEY

RELATED TO THE OS ACTIVE STATIONS BY

GPS OBSERVATIONS

Unless otherwise stated, all services shown on this plan have been surveyed using

approved detectors and the connections between manholes, if not traced, are assumed

to be direct.

No guarantee can be given that all services have been shown.

In ideal conditions the depth accuracies for the underground utilities located is +/- 10%

of depth.

Where services are shown as 'Taken From Records' on the drawing we are not liable for

any loss that may arise due to a lack of accuracy in that guided information.

Due to BT's policy we are not permitted to lift their inspection chamber covers.

Reference should be made to the methodology used on site as detailed within the latest

version of 40SEVEN's Site Procedures for Utility Location Surveys.

Excavations in the vicinity of services shown are to be carried out with due diligence

(Ref: HS(G)47.)

The following text* is an extract from Surveys of Land, Buildings and Utility Surveys at

scales of 1:500 and Larger issued by the Royal Institute of Chartered Surveyors

December 2014.

*Electronic tracing is a reliable method of locating buried services. On heavy, built up

sites 85% completeness is probably all that can be expected.

*Plan accuracies of the order of + or - 150mm may be achieved but this figure will

depend on the depth of the service below ground level. Where similar services run in

close proximity, separation may be impossible. Successful tracing of non-metallic

pipes may be limited.

*Existing record information showing underground services is often incomplete and of

doubtful accuracy. It should be regarded only as an indication and cannot be

guaranteed.

Read in conjunction with existing records.

Utility routes and text shown in dark grey are from existing records.

Drainage routes with a pipe diameter of 300mm or greater are shown as the pipe width along with

continuous line style.

For additional copies please contact 40SEVEN.

Services plotted outside survey extents should not be considered to be exhaustive.

AC Asbestos Cement

ACU Air Conditioning Unit

AD Assumed Direction

AR Assumed Route

AV Air Valve

BB Belisha Beacon

BD Back Drop

BdL Bed Level

BH Borehole

Bk Brick

BL Basement Light

BO Bollard

BR Brick

BS Bus Stop

BT British Telecom Cover

BTB British Telecom Box

BW Brick Wall

B/W Barbed Wire Fence

Cam Camera

CAT Catenary Level

C/B Close Borded Fence

CC Control Cabinet

CH Chainage

ChL Channel Level

CI Cast Iron

C/I Corrugated Iron Fence

CL Cover Level

C/L Chain Link Fence

Co Concrete

CP Catch Pit

CpL Coping Level

CrB Crash Barrier

CTV Cable TV

CUL Culvert

CW Concrete Wall

DI Ductile Iron

dil Dilapidated

dis Disused

D/S Downstream

DSW Dry Stone Wall

EB Electricity Box

EC Electricity Cover

E/F Electric Fence

EOT End of Trace

EP Electricity Pole

ER Earth Rod

FC Fuel Cover

FFL Finished Floor Level

FH Fire Hydrant

FO Fibre Optic Cover

FS Flag Staff

G Gully

GPRI Ground Penetrating

Radar Inconclusive

GV Gas Valve

H/R Hand Rail

IC Inspection Cover

IL Invert Level

I/R Iron Rail Fence

KO Kerb Outlet

LB Letter Box

LC Lighting Column

LH Lamp Hole

LOR Loss Of Reflection

LOS Loss Of Signal

MB Mooring Bollard

M/C Multiple Cables

MH Manhole Cover

Mkr Marker Post

MP Mile Post/Stone

NFI No Further Information

NM Node Marker

NP Name Plate

NPV No Pipes Visible

OSA Off Survey Area

P Post

PBM Permanent Bench Mark

PE Polyethylene

PGM Permanent Ground

Marker

PL Plastic

P/L Palisade Fence

PM Parking Meter

P/R Post and Rail Fence

PU Pump

PVC Polyvinylchloride

P/W Post and Wire Fence

PZ Piezometer

RE Rodding Eye

Ri Riser

RL Rail Level

RP Reflector Post

RS Road Sign

RWP Rain Water Pipe

R/W Retaining Wall

S Stump

SA Survey Abandoned

S/A Soakaway

SC Speed Camera

S/F Safety Fence

SI Spun Iron

SL Soffit Level

SP Sign Post

Spr Spring

S/R Steel Railings

SS Sonde Stops

ST Stop Tap

Stn Survey Station

SV Sluice Valve

SVP Soil Vent Pipe

SW Stone Wall

Tac Tactile Paving

TBM Temporary Bench Mark

TC Telecom Cover

TCB Telephone Call Box

TCP Telephone Call Post

TFR Taken From Records

TH Trial Hole / Pit

ThL Threshold Level

Tk Tank

TOW Top Of Wall

TP Telegraph Pole

TOS Top of Silt

U/S Upstream

UTGA Unable to Gain Access

UTL Unable to Locate

UTR Unable to Raise

UTS Unable to Survey

UTT Unable to Trace

VC Vitrified Clay

VDP Vehicle Detector Pads

VP Vent Pipe

VR Vapour Recovery

VTP Vertical Pipe

W Water Cover

WL Water Level

WM Water Meter

W/M Wire Mesh Fence

WO Water Wash Out

WS Window Sample

WV Wheel Valve

Survey Extents

Photo Position

* Please Note:

Utility routes shown in dark grey & with line type (r) are from existing records.

Example:

ABBREVIATIONS

DISCLAIMER

NOTES

GPR Ground Anomaly

GPR Geological Movement

GPR Reinforcement

GPR Underground Structure

GPR Underground Void

Survey Type Quality Level Post-Processing

Location AccuracySupporting Data

Horizontal VerticalD Desktop utility

Records SearchQL-D

- Undefined Undefined-

C SiteReconnaisance

QL-C- Undefined Undefined

A segment of utility whose location is demonstrated by visual reference to street furniture,topographical featuresor evidence of previous street works (reinstatement scar).

B Detection QL-B4 No Undefined Undefined A utility segment which is suspected to exist but has not been detected and is therefore shownas an assumed route.

QL-B3 No ±500mm Undefined(No reliable depth

measurement possible)

Horizontal location only of the utility detected by one of thegeophysical techniques used.

QL-B3P Yes

QL-B2 No ±250mm or 40%of detected depth

whichever is greater

±40% ofdetected depth

Horizontal and vertical location of the utility detected by oneof the geophysical techniques used.

QL-B2P Yes

QL-B1 No ±150mm or 15%of detected depth

whichever is greater

±15% ofdetected depth

Horizontal and vertical location of the utility detected by oneof the geophysical techniques used.

QL-B1P Yes

A Verification QL-A - ±50mm ±25mm Horizontal and vertical location of the top and/or bottomof the utility.

1 2

Page 2: 2 of 2 A0 - 40 Seven · 2019-06-04 · CH Chainage ChL Channel Level CI Cast Iron C/I Corrugated Iron Fence CL Cover Level C/L Chain Link Fence Co Concrete CP Catch Pit CpL Coping

GPR Scan 416

G

P

R

S

can 418

8

.2

4

8

.

3

2

8

.

2

7

9.0

8

8.8

2

1

2

5

P

E

REV. DETAILS BY

GRID DATUM

SURVEYED BY: DRAWN BY:

SCALE:

APPROVED BY:

SURVEY DATE:

REV:

DATE

CLIENT:

PROJECT TITLE:

DRAWING TITLE:

LEEDS

E-Mail: [email protected] Web site: www.40seven.com

LONDON

01732 7406960113 201 9700

Close Circuit Television

British Telecom

Surface Drainage

Combined Drainage

Telecommunications

Cable Television

Foul Drainage

Unknown

Fibre Optics

Gas

Water

Electricity

Ducting

Traffic Light System

Unknown Route Located By GPR

Overhead Electricity

Overhead Telecom

GPR Image Position

SHEET LAYOUT

UTILITY LEGEND

Transport for London

DRAWING NUMBER:

SHEET NUMBER:

SEDDON CONSTRUCTION LTD

PLODDER LANE

EDGE FOLD

BOLTON BL4 0NN

WEST LANE

TOPOGRAPHICAL & UTILITY MAPPING SURVEY

WEST LANE

FORMBY

DH / SC NC GJ

1:200 @ A0 02/2019

1678_P

2 of 2 A0

ORDNANCE SURVEY

RELATED TO THE OS

ACTIVE STATIONS BY

GPS OBSERVATIONS

ORDNANCE SURVEY

RELATED TO THE OS ACTIVE STATIONS BY

GPS OBSERVATIONS

Unless otherwise stated, all services shown on this plan have been surveyed using

approved detectors and the connections between manholes, if not traced, are assumed

to be direct.

No guarantee can be given that all services have been shown.

In ideal conditions the depth accuracies for the underground utilities located is +/- 10%

of depth.

Where services are shown as 'Taken From Records' on the drawing we are not liable for

any loss that may arise due to a lack of accuracy in that guided information.

Due to BT's policy we are not permitted to lift their inspection chamber covers.

Reference should be made to the methodology used on site as detailed within the latest

version of 40SEVEN's Site Procedures for Utility Location Surveys.

Excavations in the vicinity of services shown are to be carried out with due diligence

(Ref: HS(G)47.)

The following text* is an extract from Surveys of Land, Buildings and Utility Surveys at

scales of 1:500 and Larger issued by the Royal Institute of Chartered Surveyors

December 2014.

*Electronic tracing is a reliable method of locating buried services. On heavy, built up

sites 85% completeness is probably all that can be expected.

*Plan accuracies of the order of + or - 150mm may be achieved but this figure will

depend on the depth of the service below ground level. Where similar services run in

close proximity, separation may be impossible. Successful tracing of non-metallic

pipes may be limited.

*Existing record information showing underground services is often incomplete and of

doubtful accuracy. It should be regarded only as an indication and cannot be

guaranteed.

Read in conjunction with existing records.

Utility routes and text shown in dark grey are from existing records.

Drainage routes with a pipe diameter of 300mm or greater are shown as the pipe width along with

continuous line style.

For additional copies please contact 40SEVEN.

Services plotted outside survey extents should not be considered to be exhaustive.

AC Asbestos Cement

ACU Air Conditioning Unit

AD Assumed Direction

AR Assumed Route

AV Air Valve

BB Belisha Beacon

BD Back Drop

BdL Bed Level

BH Borehole

Bk Brick

BL Basement Light

BO Bollard

BR Brick

BS Bus Stop

BT British Telecom Cover

BTB British Telecom Box

BW Brick Wall

B/W Barbed Wire Fence

Cam Camera

CAT Catenary Level

C/B Close Borded Fence

CC Control Cabinet

CH Chainage

ChL Channel Level

CI Cast Iron

C/I Corrugated Iron Fence

CL Cover Level

C/L Chain Link Fence

Co Concrete

CP Catch Pit

CpL Coping Level

CrB Crash Barrier

CTV Cable TV

CUL Culvert

CW Concrete Wall

DI Ductile Iron

dil Dilapidated

dis Disused

D/S Downstream

DSW Dry Stone Wall

EB Electricity Box

EC Electricity Cover

E/F Electric Fence

EOT End of Trace

EP Electricity Pole

ER Earth Rod

FC Fuel Cover

FFL Finished Floor Level

FH Fire Hydrant

FO Fibre Optic Cover

FS Flag Staff

G Gully

GPRI Ground Penetrating

Radar Inconclusive

GV Gas Valve

H/R Hand Rail

IC Inspection Cover

IL Invert Level

I/R Iron Rail Fence

KO Kerb Outlet

LB Letter Box

LC Lighting Column

LH Lamp Hole

LOR Loss Of Reflection

LOS Loss Of Signal

MB Mooring Bollard

M/C Multiple Cables

MH Manhole Cover

Mkr Marker Post

MP Mile Post/Stone

NFI No Further Information

NM Node Marker

NP Name Plate

NPV No Pipes Visible

OSA Off Survey Area

P Post

PBM Permanent Bench Mark

PE Polyethylene

PGM Permanent Ground

Marker

PL Plastic

P/L Palisade Fence

PM Parking Meter

P/R Post and Rail Fence

PU Pump

PVC Polyvinylchloride

P/W Post and Wire Fence

PZ Piezometer

RE Rodding Eye

Ri Riser

RL Rail Level

RP Reflector Post

RS Road Sign

RWP Rain Water Pipe

R/W Retaining Wall

S Stump

SA Survey Abandoned

S/A Soakaway

SC Speed Camera

S/F Safety Fence

SI Spun Iron

SL Soffit Level

SP Sign Post

Spr Spring

S/R Steel Railings

SS Sonde Stops

ST Stop Tap

Stn Survey Station

SV Sluice Valve

SVP Soil Vent Pipe

SW Stone Wall

Tac Tactile Paving

TBM Temporary Bench Mark

TC Telecom Cover

TCB Telephone Call Box

TCP Telephone Call Post

TFR Taken From Records

TH Trial Hole / Pit

ThL Threshold Level

Tk Tank

TOW Top Of Wall

TP Telegraph Pole

TOS Top of Silt

U/S Upstream

UTGA Unable to Gain Access

UTL Unable to Locate

UTR Unable to Raise

UTS Unable to Survey

UTT Unable to Trace

VC Vitrified Clay

VDP Vehicle Detector Pads

VP Vent Pipe

VR Vapour Recovery

VTP Vertical Pipe

W Water Cover

WL Water Level

WM Water Meter

W/M Wire Mesh Fence

WO Water Wash Out

WS Window Sample

WV Wheel Valve

Survey Extents

Photo Position

* Please Note:

Utility routes shown in dark grey & with line type (r) are from existing records.

Example:

ABBREVIATIONS

DISCLAIMER

NOTES

GPR Ground Anomaly

GPR Geological Movement

GPR Reinforcement

GPR Underground Structure

GPR Underground Void

Survey Type Quality Level Post-Processing

Location AccuracySupporting Data

Horizontal VerticalD Desktop utility

Records SearchQL-D

- Undefined Undefined-

C SiteReconnaisance

QL-C- Undefined Undefined

A segment of utility whose location is demonstrated by visual reference to street furniture,topographical featuresor evidence of previous street works (reinstatement scar).

B Detection QL-B4 No Undefined Undefined A utility segment which is suspected to exist but has not been detected and is therefore shownas an assumed route.

QL-B3 No ±500mm Undefined(No reliable depth

measurement possible)

Horizontal location only of the utility detected by one of thegeophysical techniques used.

QL-B3P Yes

QL-B2 No ±250mm or 40%of detected depth

whichever is greater

±40% ofdetected depth

Horizontal and vertical location of the utility detected by oneof the geophysical techniques used.

QL-B2P Yes

QL-B1 No ±150mm or 15%of detected depth

whichever is greater

±15% ofdetected depth

Horizontal and vertical location of the utility detected by oneof the geophysical techniques used.

QL-B1P Yes

A Verification QL-A - ±50mm ±25mm Horizontal and vertical location of the top and/or bottomof the utility.

1 2