2 ½ power storm gunite jet (210-7800 & 210-7810) … · 4" longer than estimated finish length....

3
2 ½" POWER STORM GUNITE JET (210-7800 & 210-7810) INSTALLATION INSTRUCTIONS AND PRESSURE TESTING 1. Hang Power Gunite Jet Body with ties through preset holes onto steel rebar. 3. Glue 2 ½" cap onto end of pipe for pressure test before guniting. 5. Cut a piece of 1" PVC pipe a couple of inches longer than the 2 ½" pipe and glue the threaded retainer ring to it. 7. Draw a reference line on the 1" PVC pipe, flush with the back edge of the measuring tool. 8. Remove the 1" pipe assembly from the jet body assembly and realign the measuring tool with the reference line. Make a new line at the Power Storm Gunite Jet setback on the measuring tool. 6. Insert 1" PVC pipe assembly through the niche and up to the jet body assembly and thread in. Slide the Gunite Pipe Measuring Tool (218-1890A) over the end of the pipe until flush against the plaster niche. 2. Estimate needed length of 2 ½" PVC pipe by thickness of wall. Cut 2 ½" PVC pipe at least 4" longer than estimated finish length. Then glue 2 ½" PVC pipe to body. Ties Steel Rebar 2" Water Body (211-3060 - Tee (shown)) (211-3040 - Straight) 1 ½" Air Estimated Length 8" min. from back of jet body 4" 2 ½" Cap 4. While guniting, scoop out gunite around the 2 ½" PVC pipe, allowing for the plaster niche (218-7650). Before plastering, cut the 2 ½" pipe so that the plastic niche will fit flush with the finished wall. Glue the plaster niche onto the pipe, then cover the niche with tape for plastering. Gunite Wall Chip out wall around pipe 2 ½" PVC Pipe SCH 40 Plaster Niche (218-7650) Retainer Ring (219-1060) Gunite Wall Niche Gunite Pipe Measuring Tool Reference Line Reference Line New Line 1 5 6 7 8 2 3 4 810-0117.0618 ©2018 Waterway Plastics 2200 East Sturgis Road, Oxnard CA 93030 • Phone 805.981.0262 • Fax 805.981.9403 www.waterwayplastics.com • [email protected] Designed, Engineered & Manufactured in the USA.

Upload: others

Post on 23-Oct-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

  • 2 ½" POWER STORM GUNITE JET (210-7800 & 210-7810)INSTALLATION INSTRUCTIONS AND PRESSURE TESTING

    1. Hang Power Gunite Jet Body with ties through preset holes onto steel rebar.

    3. Glue 2 ½" cap onto end of pipe for pressure test before guniting.

    5. Cut a piece of 1" PVC pipe a couple of inches longer than the 2 ½" pipe and glue the threaded retainer ring to it.

    7. Draw a reference line on the 1" PVC pipe, flush with the back edge of the measuring tool.

    8. Remove the 1" pipe assembly from the jet body assembly and realign the measuring tool with the reference line. Make a new line at the Power Storm Gunite Jet setback on the measuring tool.

    6. Insert 1" PVC pipe assembly through the niche and up to the jet body assembly and thread in. Slide the Gunite Pipe Measuring Tool (218-1890A) over the end of the pipe until flush against the plaster niche.

    2. Estimate needed length of 2 ½" PVC pipe by thickness of wall. Cut 2 ½" PVC pipe at least 4" longer than estimated finish length. Then glue 2 ½" PVC pipe to body.

    Ties

    Steel Rebar

    2" Water

    Body(211-3060 - Tee (shown))

    (211-3040 - Straight)

    1 ½" Air

    Estimated Length8" m

    in. from

    back of

    jet body

    4"

    2 ½" Cap

    4. While guniting, scoop out gunite around the 2 ½" PVC pipe, allowing for the plaster niche (218-7650). Before plastering, cut the 2 ½" pipe so that the plastic niche will fit flush with the finished wall. Glue the plaster niche onto the pipe, then cover the niche with tape for plastering.

    Gunite Wall

    Chip out wallaround pipe

    2 ½" PVC PipeSCH 40

    Plaster Niche(218-7650)

    Retainer Ring(219-1060)

    Gunite Wall

    Niche

    Gunite PipeMeasuring Tool

    Reference Line

    Reference Line New Line

    1 5

    6

    7

    8

    2

    3

    4

    810-0117.0618©2018 Waterway Plastics

    2200 East Sturgis Road, Oxnard CA 93030 • Phone 805.981.0262 • Fax 805.981.9403www.waterwayplastics.com • [email protected]

    Designed,Engineered & Manufactured

    in the USA.

  • 9. At the new line drawn from the setback, cut the pipe.

    10. Create a 1" pipe tool with coupling attached to install the pipe assembly in the following steps.

    11. Install 4-6 wraps of Teflon tape around the threaded Retainer Ring, including 1 wrap over the o-ring. Dry fit the pipe tool with coupling on the end of the 1" pipe assembly. Thread the assembly into the body assembly until it is snug and the pipe tool with coupling spins freely. Remove the pipe tool from the end of the pipe assembly.

    12. Put a bead of clear silicone sealant all around the back side of the wall fitting’s flange. Prime and cement the end of the 1" pipe and fitting socket. Slide fitting onto end of 1" pipe until tight against the plaster niche.

    Retainer Ring(219-1060)

    Retainer O-Ring(805-0215)

    Reference linefrom Step 7

    New lineMAKE CUT HERE

    Coupling

    1" Pipe Tool(with coupling)

    1" Pipe Assembly

    Retainer Ring(219-1060)

    Wrap Te�on TapeCoupling

    1" Pipe Tool(with coupling)

    1" Pipe Assembly

    Wall Fitting

    Silicone

    9

    10

    11

    12

    13. Always use at least one non-adjustable internal per spa to prevent deadheading pump.

    Directional212-7610G - White212-7611G - Black212-7617G - Gray

    Roto212-7740G - White212-7741G - Black212-7747G - Gray

    Internals come installed with ½" nozzle.

    Twin Roto212-7630G - White212-7631G - Black212-7637G - Gray

    Massage212-7600G - White212-7601G - Black212-7607G - Gray

    13

    14. Align tab behind escutcheon face on jet internal with slot on wall fitting. Location of slot and tab are shown below. Push Power Storm internal into wall fitting until it snaps into place. To reduce water flow, turn clockwise. To increase water flow, turn counter-clockwise until it stops turning. To remove, continue turning counter-clockwise past stopping point. You will hear a snap to confirm release of Power Storm internal.

    15. To winterize the jet system, remove the jet internal from the wall fitting ONLY. Install a #10 rubber expansion plug inside of the fitting opening.

    16. For alternate nozzle sizes: Remove jet internal by turning counter-clockwise beyond stopping point; Pull diffuser off back of internal; With flathead screwdriver, pry nozzle out through venturi hole; Replace with desired nozzle.

    Wall

    Power Storm Jet Internal

    Power Storm Jet Internal

    PryIncluded Nozzle SizesPart No. Description217-6610 ¼" Nozzle, 8 GPM217-6600 3⁄8" Nozzle, 12 GPM217-6620 ½" Nozzle, 15 GPM217-6630 5⁄8" Nozzle, 25 GPM

    14

    15

    16

    Tab behind poly escutcheon face

    810-0117.0618©2018 Waterway Plastics

  • To prevent personal injury, shock, or property/equipment damage, an Air Spring Check Valve (2" 600-8160, 1 ½" 600-8140) must be installed on the blower stand pipe in case of a water backup in the air line.

    NOTE: If a blower is not being used, please direct the air intake toward the ground using the 2" Sweep Vent Grate Assembly (400-4130) on the Air Inlet Pipe.

    9.50"

    3.50" min. length 5.989"

    4.29"

    4.64"

    2" Socket Water

    1" SCH 40 PVC Pipe

    (not included)

    1 ½" Socket Air

    2 ½" SCH 40 PVC Pipe

    (not included)

    Blower

    Water Flow Water Flow

    AirFlow UL Listed

    Check Valve

    Air Intake

    Sweep Vent Grate Assembly(400-4130)

    AirFlow

    Air Inlet Pipe

    POWER GUNITE STRAIGHT BODY ASSEMBLY1" Spigot Air x 1 ½" Spigot Water

    (210-7800)

    POWER GUNITE TEE BODY ASSEMBLY1 ½" S Air x 2" S Water

    (210-7810)

    Threaded Retainer(219-1060)

    Plaster Niche(218-7650)

    1" PVC Pipe(not included)

    Body Only(211-3040)

    2 ½" PVC Pipe(not included)

    Wall�tting(215-6660)

    Niche included with Body Assembly Niche included with Body Assembly

    Threaded Retainer(219-1060)

    Plaster Niche(218-7650)

    1" PVC Pipe(not included)

    Wall�tting(215-6660)

    2 ½" PVC Pipe(not included)

    Body Only(211-3060)

    POWER JET BODY ASSEMBLIES

    810-0117.0618©2018 Waterway Plastics

    WARRANTYFor product registration visit: www.waterwayplastics.com.

    For Warranty questions or claims please contact point of purchase.