2. table of technical names

5
2 TABLE OF TECHNICAL NAMES

Upload: andhrimnir

Post on 21-Oct-2015

16 views

Category:

Documents


0 download

DESCRIPTION

Cable Insulation

TRANSCRIPT

Page 1: 2. Table of Technical Names

2

TABLE OFTECHNICAL

NAMES

Page 2: 2. Table of Technical Names

AL. = ALUMINIUM L.V. = LOW VOLTAGE• 14 •

COMMERCIALBRAND

GENLIS

BIGGFLEX

MOVILFLEX(SHIELDED)

MOVILFLEX

PLASTIGRON(Múltiple)

ENERGY RV

FLEXIGRON 500V

FLEXIGRON 500V

FLEXIGRON 750V

FLEXIGRON 1000V

SOLDANOF

EXZHELLENT XXI(AS)

EXZHELLENT – D(AS)

EXZHELLENT – XXI(AS)

TECHNICALNAME

H07V – UH07V – RH07V – K

H05V V – F

VC4 V –K

V V-500 – F

V V – K 0,6/1 KV

RV – 0,6/1 KV

H05RR – F

H05RN - F

H07RN – F

DN – F 0,6/1KV

H01N2 - D

ES-07Z1-K

H07Z - R

RZ1-K0,6/1KV

INTERPRETATION OFSYMBOLS

(H) COMPLIES WITH CENELECHARMONIZED STANDARDS(07) VOLTAGE 750 V(V) PVC INSULATION(U) ONE WIRE (Class 1)(R) VARIOUS WIRES(Class 2)(k) FLEXIBLE (Class 5)

(05) VOLTAGE 500 V(V) PVC INSULATION(V) PVC SHEATH(F) FLEXIBLE (Class 5)

(C4) COPPER BRAID SHIELD

(K) FLEXIBLE (class 5)

(R) RETICULATEDPOLYETHYLENE

(R) NATURAL RUBBER

(N) POLYCHLOROPRENE

(D) PROPYLENE ETHYLENE

(01) NOMINAL VOLTAGE 100V(02) (N2POLYCHLOROPRENE(D) MOBILE USES (soldering)

(Z1) HALOGEN-FREETHERMOPLASTICINSULATION

(Z) VULCANIZEDTHERMOSTABLE INSULATION

(R) RETICULATEDPOLYETHYLENE(Dt) GREEN HALOGEN-FREETHERMOPLASTIC SHEATH

CHARACTERISTICS

LINE WIRE. FIRE RESISTANT ANDFLAMEPROOF. “SPEEDY SKIN”MAXIMUM GLIDING EXTRUSIONSYSTEM. MAXIMUM SERVICETEMPERATURE: 70ºC. PRODUCTCERTIFIED: AENOR<HAR> USE: FIXEDSERVICE IN CONDUIT ANDTRUNCKING ETC.

FLEXIBLE CABLE, USE: INDOORMOBILE (F), MAXIMUM SERVICETEMPERATURE: 70ºC. FLAMEPROOF.

APPLICATIONS IN AREAS WITHELECTROSTATIC ORELECTROMAGNETICINTERFERENCES. INDOOR MOBILESERVICE (PORTABLE MACHINES,TOOLS, ETC.)

FLAMEPROOF. MAXIMUM SERVICETEMPERATURE: 70ºC. NUMBEREDCONDUCTORS. CONTROL CABLES,FIXED SERVICE (K) INDOORS OROUTDOORS.

RIGID CLASS 1 & CLASS 2 COPPERAND ALUMINIUM CONDUCTORS.FLAMEPROOF. APPLICATION: L.V.ENERGY DISTRIBUTION, INDOORS OROUTDOORS.

APPLICATION: INDOOR MOBILESERVICES, FEEDING MACHINES, TOOLSAND HEATING EQUIPMENT.

APPLICATION: INDOOR AND OUTDOORMOBILE SERVICES, FEEDING MOBILEINDUSTRIAL EQUIPMENT.

EXTRA-FLEXIBLE CLASS 6 COPPERCONDUCTOR. FLAMEPROOF.APPLICATION: FEEDING ELECTRICSOLDERING IRONS.

FIRE RESISTANT. HALOGEN-FREE.LOW CORRODIBILITY. DOES NOTGIVE OFF OPAQUE SMOKE. MAX.SERVICE TEMPERATURE: 70ºC.NOMINAL VOLTAGE: 750V.

AS PER ABOVE, EXCEPT FOR MAX.SERVICE TEMPERATURE: 90ºC.

AS PER ABOVE. NOMINAL VOLTAGE:0.6/1kV. USES: PREMISES OPEN TO THEPUBLIC, CINEMAS, HOSPITALS,THEATRES, METROS, TV AND RADIOSTUDIOS, ETC.

Page 3: 2. Table of Technical Names

• 15 •

COMMERCIALBRAND

SEGURFOC - 331(AS+)

ENERGYRV – K FOC

ARMIGRON –F

ARMIGRON – M(UNFIRE)

AEROPREX

VULCAN

VULCAN MAR

VULCAN MINE

HERSATENE

VULPREN

TECHNICAL NAME

RV – K 0,6/1KV

RVFAV – 0,6/1 KVRVFV – 0,6/1KV

RVh MA Vh –0,6/1KV

RVh MVh –0,6/1KV

RZ – 0,6/1KV

DN – 0,6/1KV

DN – 0,6/1KVDNC4V – 0,6/1KVDNZ5V – 0,6/1KV

V VMV – 0,6/1KVDM2N – 0,6/1KVDS1N – 0,6/1KV

RHZ1 – 6/10KVHASTA 18/36KVHIGH VOLTAGE26/45 – 36/66110KV / 132KV220KV / 400KV

DHZ1 – 6/10KVUP TO 132 KV

INTERPRETATION OFSYMBOLS

(FA) ALUMINIUM TAPEARMOUR(F) GALVANIZED STEEL TAPEARMOUR

(Vh) HYDROCARBONRESISTANT PVC(MA) ALUMINIUM WIREARMOUR(M) GALVANIZED STEEL WIREARMOUR

(Z) VISIBLE CABLING

(D) PROPYLENE ETHYLENE(N) POLYCHLOROPRENE

(C4) COPPER BRAID SHIELD(Z5) GALVANIZED WIRE BRAIDARMOUR

(M2) STEEL HEADS(S1) SAFETY SHIELD

(Z1) POLYETHYLENE(H) RADIAL FIELD CABLE

CHARACTERISTICS

CONDUCTORS: RIGID CLASS 1, SEMI-RIGID CLASS 2, FLEXIBLE CLASS 5.FIRE RESISTANT, HALOGEN-FREE,LOW CORRODIBILITY, DOES NOT GIVEOFF OPAQUE SMOKE. MAINTAINSSERVICE INTEGRITY IN THE CASE OF FIRE.

FLEXIBLE CLASS 5 CONDUCTORS.FIXED SERVICE. CABLE FOR L.V.DISTRIBUTION, INDOORS OROUTDOORS. MAXIMUM SERVICETEMPERATURE: 90ºC.

COPPER CONDUCTORS, RIGID (CLASS1) AND SEMI-RIGID (CLASS 2) CABLEWITH HIGH MECHANICAL AND ANTI-TERMITE PROTECTION.

AS PER ABOVE. USES: REFINERIES,PETROCHEMICAL INDUSTRIES,PETROL STATIONS, POTENTIALLYEXPLOSIVE INSTALLATIONS,. FIRERESISTANT CABLE.

CABLE FOR L.V. DISTRIBUTION. CLASS2, ALUMINIUM OR COPPERCONDUCTORS. USES: OVERHEADPOWERLINE NETWORKS OR CABLINGMOUNTED ON FACADES OFBUILDINGS.

CABLE FOR L.V. DISTRIBUTION, INDOORSOR OUTDOORS. FIXED SERVICE. MAX.SERVICE TEMPERATURE: 90º C.

RIGID CABLES. INSTALLATION ONSHIPS, AS PER ABOVE. ELECTRICPROTECTION, MECHANICALPROTECTION.

RIGID ARMOURED CABLES, FIXEDINSTALLATION, FLEXIBLECONDUCTOR. SEMI -FIXEDINSTALLATION. FLEXIBLECONDUCTOR. MOBILE INSTALLATION.

MEDIUM AND HIGH-VOLTAGEDISTRIBUTION CABLES, IN COPPEROR ALUMINIUM

CABLES FOR TRANSPORTINGEXTRA-HIGH VOLTAGES.

MEDIUM AND HIGH-VOLTAGEDISTRIBUTION CABLES IN COPPER ORALUMINIUM.

AL. = ALUMINIUM L.V. = LOW VOLTAGE

Page 4: 2. Table of Technical Names

• 16 •

COMMERCIALBRAND

JETLAN 5e+

JETLAN 6+

JETLANOPTIC

TECHNICALNAME

CATEGORY 5e

CATEGORY 6+

FIBRE-OPTIC

CHARACTERISTICS

UTP AND FTP STRUCTURED CATEGORY5C CABLING SYSTEM. PERFORMANCEUP TO 200MHz. CABLES WITHHALOGEN-FREE VERSION AND DELTACERTIFICATION.

UTP AND FTP STRUCTURED CATEGORY6 CABLING SYSTEM. PERFORMANCEUP TO 250MHz. CABLES WITHHALOGEN-FREE VERSION ANDINDIVIDUAL PERFORMANCE UP TO500MHz, AND DELTA CERTIFICATION.

STRUCTURED FIBRE-OPTIC CABLINGSYSTEM, INCLUDING A FULL RANGEOF INDOOR AND OUTDOOR CABLES,AS WELL AS PANELS, PATCH-CORDS,CONNECTORS, ETC. ALL CABLES AREHALOGEN-FREE.

AL. = ALUMINIUM L.V. = LOW VOLTAGE

INTERPRETATIONOF SYMBOLS

2.7 INTERPRETATION OF SYMBOLS

*Standard characters that are notcontemplated in CENELEC.

Cu = Copper Fe = Iron Al = Aluminium

CORRESPONDENCE WITH STANDARDIZATION

COMPLIES WITH HARMONIZED REGULATIONS

A NATIONAL TYPE CABLE

NATIONAL TYPE CABLE

H

A

N (ES)

H05V-K

A05V V-K

ES 07Z1-K

NOMINAL VOLTAGE

NOMINAL VOLTAGE 300/300V

NOMINAL VOLTAGE 300/500V

NOMINAL VOLTAGE 450/750V

03

05

07

H03VH-H

H05V-K

H07V-K

INSULATIONS AND NON-METALLIC COVERINGS

*D

E

E 2

*I

J

PROPYLENE ETHYLENE RUBBER

POLYETHYLENE

HIGH DENSITY POLYETHYLENE

HYPALON

FIBREGLASS BRAID

DHV

EV V

E2V V

DI

SJ

Page 5: 2. Table of Technical Names

METALLIC COVERINGS

C3

*F

FA

F3

*H

L

C

C4

*M

*MA

*O

*01

*02

Z5

CORRUGATED COPPER SHIELD

GALVANIZED STEEL TAPE ARMOR

ALUMINIUM TAPE ARMOR

CORRUGATED STEEL ARMOR

RADIAL FIELS SHIELD

LEAD COVERING

CONCENTRIC COPPER CONDUCTOR

COPPER BRAID

GALVANIZED STEEL WIRE ARMOR

ALUMINIUM WIRE ARMOR

COLLECTIVE METALLIC SHIELD

INDIVIDUAL SHIELD

COLLECTIVE SHIELD

STEEL BRAID

VC3V

RVFV

RFAV

RVF3V

DHV

DLV

V VCV

VC4V

V VMV

VMAV

RVOV

E01V

E02V

VZ5V

OTHER SYMBOLS

WITHOUT GROUND CORE (GREEN/YELLOW)

WITH GROUND CORE (GREEN/YELLOW)

X

G

3 x 2,5 mm2

3 G 2,5 mm2

INSULATIONS AND NON-METALLIC COVERINGS

N

P

Q

R

S

T

V

*/R

V5

Z

Z1

POLYCHLOROPRENE

INSULATION PAPER

POLYURETHANE

NATURAL RUBBER

SILICONE RUBBER

TEXTILE BRAID

POLYVINYL CHLORIDE

CROSS LINKED POLYETHYLENE

OIL RESISTANT PVC

HALOGEN-FREE THERMOSET COMPOUND

HALOGEN-FREE THERMOPLASTIC COMPOUND

N

PPV

DQ

HO7RR-F

SJ

H03RT-K

V V

RV-K

V V5

HO7Z-R

07Z1-KRZ1-K

• 17 •*Standard characters that are notcontemplated in CENELEC.

Cu = Copper Fe = Iron Al = Aluminium