Test Report issued under the responsibility of www.nemko.com This Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by a laboratory having special agreement with Nemko. TEST REPORT IEC 60065 Audio, video and similar electronic apparatus - Safety requirements Report Reference No. .................... : 125414 Date of issue .................................... : 2009-04-06 Total number of pages ..................... : 40 page and refer page 5 CB/CCA Testing Laboratory Name: Nemko Taiwan Phone: (+ 886) 2 8797 8790 Address ............................................ : 5 Fl., No. 409, Sec.2, Tiding Blvd., Neihu, Taipei 114, Taiwan Applicant’s name ........................... : Eastern Frontier Co., Ltd. Address ............................................ : 13TH FL, BLK B, CHUNG MEI CENTRE, 15 HING YIP ST., KWUN TONG, KOWLOON, HONG KONG Test specification: Standard .......................................... : IEC 60065:2001(7 th edition) + Amd 1:2005 EN 60065: 2002 + A1: 2006 Test procedure................................. : CB Non-standard test method…………..: N/A Test Report Form No. .................... : IEC60065_I Test Report Form(s) Originator ....................... : Intertek Semko AB Master TRF ..................................................... : 2008-05 Copyright © 2008 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.

Upload: others

Post on 05-Jul-2020

18 views

Category:

Documents


0 download

TRANSCRIPT

Page 1:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

Test Report issued under the responsibility of

www.nemko.com

This Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by a laboratory having special agreement with Nemko.

TEST REPORT

IEC 60065 Audio, video and similar electronic apparatus - Safety requirements

Report Reference No. .................... : 125414

Date of issue .................................... : 2009-04-06

Total number of pages..................... : 40 page and refer page 5

CB/CCA Testing Laboratory Name: Nemko Taiwan Phone: (+ 886) 2 8797 8790

Address............................................ : 5 Fl., No. 409, Sec.2, Tiding Blvd., Neihu, Taipei 114, Taiwan

Applicant’s name ........................... : Eastern Frontier Co., Ltd.

Address............................................ : 13TH FL, BLK B, CHUNG MEI CENTRE, 15 HING YIP ST., KWUN TONG, KOWLOON, HONG KONG

Test specification:

Standard .......................................... : IEC 60065:2001(7th edition) + Amd 1:2005 EN 60065: 2002 + A1: 2006

Test procedure................................. : CB

Non-standard test method…………..: N/A

Test Report Form No. .................... : IEC60065_I Test Report Form(s) Originator ....................... : Intertek Semko AB

Master TRF ..................................................... : 2008-05

Copyright © 2008 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.

If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB scheme procedure shall be removed.

This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.

Page 2:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

Test Report issued under the responsibility of

www.nemko.com

This Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by a laboratory having special agreement with Nemko.

Test item description..................... : Switching power supply (direct plug-in adapter with

interchangeable or fixed plug)

Trade Mark....................................... : 1) ; 2)

Manufacturer.................................... : Same as applicant

Model/Type reference...................... : EFS01801290139.. The dots “..” definition: CE (European plug and United Kingdom plug), AU (Australia plug), JP (fixed Japan plug), and AP (Korea plug, China plug, Taiwan plug and Hong Kong plug

Ratings............................................. : I/P: 0.68A 100-240V~ 50/60Hz DC-output: 1.39A 12.9V

Portable apparatus

Dimension: Max. 70.0 x 63.5 x 34 mm Mass: 140g

Page 3:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 3 of 40 -

Report No. 125414

TRF No. IEC60065_I

Testing procedure and testing location:

CB Testing Laboratory:

Testing location/ address ...................... : Nemko Taiwan 5 Fl., No. 409, Sec.2, Tiding Blvd., Neihu, Taipei 114, Taiwan

Associated CB Test Laboratory:

Testing location/ address ...................... :

Tested by (name + signature) ..... : Eric Chen

Approved by (+ signature)........... : Andy Lee

Testing procedure: TMP

Tested by (name + signature) ..... :

Approved by (+ signature)............ :

Testing location/ address ...................... :

Testing procedure: WMT

Tested by (name + signature) ..... :

Witnessed by (+ signature) .......... :

Approved by (+ signature)........... :

Testing location/ address ...................... :

Testing procedure: SMT

Tested by (name + signature) ..... :

Approved by (+ signature)............ :

Supervised by (+ signature) ........ :

Testing location/ address ………………..:

Testing procedure: RMT

Tested by (name + signature) ..... :

Approved by (+ signature)............ :

Supervised by (+ signature) ........ :

Testing location/ address ...................... :

Page 4:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 4 of 40 -

Report No. 125414

TRF No. IEC60065_I

Summary of testing:

Flammability category according to IEC60707: FV 0 is considered to be equal to flammability class V-0. FV 1 is considered to be equal to flammability class V-1. FV 2 is considered to be equal to flammability class V-2.

Tests performed (name of test and test clause):5 Marking and instructions 7 Heating under normal operating conditions 8 Constructional requirements with regard to the protection against electric shock 9 Electric shock hazard under normal operating conditions 10 Insulation requirements 11 Fault conditions 12 Mechanical strength 13 Clearances and creepage distances 14 Components 15 Terminals 17 Electrical connections and mechanical fixings 19 Stability and mechanical hazards 20 Resistance to fire

Testing location: Refer page 2

Summary of compliance with National Differences: All CENELEC countries and countries listed except Canada (CA) and United States of America (US) in CB Bulletin No. 112A, dated December 2006 as follows: Argentina (AR), Austria (AT), Australia (AU), Belgium (BE), Brazil (BR), Switzerland (CH), China (CN), Serbia and Montenegro (CS), Czech Republic (CZ), Germany (DE), Denmark (DK), Finland (FI), France (FR), Greece (GR), United Kingdom (GB), Hungary (HU), Italy (IT), Kenya (KE), Republic of Korea (KR), Malaysia (MY), The Netherlands (NL), Norway (NO), Poland (PL), Portugal (PT), Russian Federation (RU), Sweden (SE), Singapore (SG), Slovenia (SI), Slovakia (SK) and Ukraine (UA).

Copy of marking plate:

Page 5:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 5 of 40 -

Report No. 125414

TRF No. IEC60065_I

Name and address of production-sites (Factories): 1. EASTERN FRONTIER(SHENZHEN)CO., LTD. Factory Bldg #A Hua Fa Road, Ind. Area Da Lang Village Long Han Shenzhen, China 2. EASTERN FRONTIER(SHENZHEN)CO., LTD. Factory Bldg#A Hua Fa Road, Ind. Area Da Lang ST., Bao An, Shenzhen, China List of attachments: PCB layout (2 pages), Photos (9 pages), Transformer specification (2 pages), European group differences with others contries difference (16 pages), Europe plug report (12 pages)

Page 6:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 6 of 40 -

Report No. 125414

TRF No. IEC60065_I

Test item particulars.................................................. : Classification of installation and use............................ : IP20 Supply connection ....................................................... : Pluggable equipment type A ...................................................................................... : ...................................................................................... : Possible test case verdicts: - test case does not apply to the test object .................: N (N/A) - test object does meet the requirement.......................: P (Pass) - test object does not meet the requirement.................: F (Fail) Testing…………………………………………………....:

Date of receipt of test items ..........................................: March, 2009 Date(s) of performance of tests ....................................: March, 2009 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report, a point (comma) is used as the decimal separator. List of test equipment must be kept on file and available for review. General product information: The sample(s) tested complies with the requirements of IEC 60065: 2001+Amd 1/EN 60065:2002+A1. Compliance with European Special National Conditions, Annex ZB, and A – Deviations, Annex ZC, is recorded at the end of this report. Additional information: 1. The equipment under tests is Class II switching type power adapter with interchangeable or fixed plug. 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been evaluated and complies with IEC 60884-1 and EN 50075, others plugs should be checked when marketed in relevant country. The whole unit (include interchangeable plug) have been evaluated additional plug tests as follow and compliance with standard of IEC 60884-1 and EN50075: 1. 25 times tumbiling barrel test. 2. Torgue test. 3. Ball pressure test. 3. The United Kingdom plug has been tested BS1363-1 part 1, 12.1, 12..2, 12.3, 12.9, 12.11, 12.12, 12.16 and 12.17. 4. Load condition: Loaded to rating. Maximum recommended ambient (Tmra): 45°C

Page 7:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 7 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

3 General requirements P Safety class of the

apparatus …………………………: Class II P

4 General test conditions P 4.1.4 Ventilation instructions require the use of the test box Positioned according to users

manual. P

5 Marking and instructions P Comprehensible and easily

discernible ……………...: On the outside of the enclosure.

P

Permanent durability against water and petroleum spirit ……………………………………………………..:

Tested with water / spirit. P

5.1 a) Identification, maker ………………………………..:1) ; 2)

P

b) Model number or type reference …………………..:

EFS01801290139.. P

c) Class II symbol if applicable ………………………..:

Class II symbol (IEC 60417, symbol No. 5172) is applied.

P

d) Nature of supply ………………………………….....:

AC symbol ( ~ ) used. P

e) Rated supply voltage and symbol …………………:

100-240V P

f) Mains frequency if safety dependant ……......…….: 50/60Hz P g) Rated current or power consumption for apparatus supplied by supply apparatus for general use ………:

The apparatus is connection to an a.c. mains supply

N

Measured current or power consumption …………...: N

Deviation % (max 10%) ……………………………....:

N

h) Power consumption marking for apparatus other than single phase ……………………………..……….:

The apparatus is connection to an single phase a.c. mains supply

N

i) Rated current or power consumption for apparatus intended for connection to an a.c. mains supply ……:

0.68A P

Measured current or power consumption …..…….....: Considered, refer to appended table 7.1.

P

Page 8:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 8 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

Deviation % (max 10%) ……………………………....:

The steady state input current of the apparatus measured at RATED SUPPLY VOLTAGE not exceed the marked value by more than 10 % under NORMAL LOAD.

P

5.2 Earth terminal …………………………………………..:

Class II apparatus. N

Hazardous live terminals ………………………………:

No live parts accessible. N

Supply output terminals (other than mains) ………....: No socket outlet for providing power to other apparatus.

N

5.3 Use of triangle with exclamation mark ……………….:

The mark is shown on the electrical diagram above every safety critical components.

P

5.4 Instructions for use …………………………………….: Refer to below. N

5.4.1

a) Mains powered equipment not exposed to dripping or splashing. Warning concerning objects filled with liquid, etc. ……………………………………………….:

Instructions and markings shall be in a language acceptable for the country where the equipment is to be used.

N

b) Hazardous live terminals, instructions for wiring ...:

No live terminal. N

c) Instructions for replacing lithium battery …………..:

No battery. N

d) Class I earth connection warning ………………….:

Class II apparatus. N

e) Instructions for multimedia system connection …..: No direct connected to multimedia system.

N

f) Special stability warning for attachment of the apparatus to the floor/wall ……………………………:

Direct plug-in apparatus. N

g) Warning: battery exposure to heat ………………..: Not such equipment. N h) Warning: protective film on CRT face …………….: Not such equipment. N 5.4.2 Disconnect device: plug/coupler or all-pole mains

switch location, accessibility and markings ………….:

The plug will be acting as disconnect device.

P

Instructions for permanently connected equipment ...:

The apparatus is not for permanent connection.

N

Marking, signal lamps or similar for completely disconnection from the mains ……………………...…:

Not such equipment. N

Page 9:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 9 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

6 Hazardous radiations N 6.1 Ionizing radiation < 36 pA/kg

(0,5 mR/h) …………….: No radiation hazard. N

Ionizing radiation under fault condition ……………….:

N

6.2 Laser radiation, emission limits to IEC 60825-1 …….: N Emission limits under fault

conditions ………………..: N

7 Heating under normal operating conditions P 7.1 Temperature rises not exceeding specified values;

fuse links and other protective devices defeated …...:No fuse links operate during normal operating operation. (see appended table 7.1)

P

7.1.1 Temperature rise of accessible parts ………………..: (see appended table 7.1) P 7.1.2 Temperature rise of parts providing electrical

insulation ………………………………………………..:

(see appended table 7.1) P

7.1.3 Temperature rise of parts acting as a support or as a mechanical barrier ……………………………………..:

No such parts used. N

7.1.4 Temperature rise of windings …………………………:

(see appended table 7.1) P

7.1.5 Parts not subject to a limit under 7.1.1 to 7.1.4 (see appended table 7.1) P 7.2 Softening temperature of insulating material

supporting parts conductively connected to the mains carrying a current > 0,2 A at least 150

oC ……………:

1. PCB: Epoxy. 2. Plug, see appended table 7.2. 3. For bobbin of transformer arephenolic.

P

8 Constructional requirements with regard to the protection against electric shock P 8.1 Conductive parts covered by lacquer, paper,

untreated textile oxide films and beads etc. considered to be bare …………………………………:

Considered. P

8.2 No shock hazard when changing voltage setting device, fuse-links or handling drawers etc. ………….:

No voltage setting device is provided.

N

8.3 Insulation of hazardous live parts not provided by hygroscopic material …………………………………..:

No hygroscopic materials used. N

Page 10:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 10 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

8.4 No risk of electric shock from accessible parts or from parts rendered accessible following the removal of a cover which can be removed by hand …………..:

No risk of electric shock after enclosure removed.

P

8.5 Class I equipment ……………………………………...:

Class II apparatus. N

Basic insulation between hazardous live parts and earthed accessible parts ………………………………:

N

Resistors bridging basic insulation complying with 14.1 a) …………………………………………………..:

N

Capacitors bridging basic insulation complying with 14.2.1 a) …………………………………………….......:

N

Protective earthing terminal …………………………...:

N

8.6 Class II equipment and Class II constructions within Class I equipment ……………………………………...:

Refer to below. P

Double or reinforced insulation between hazardous live parts and accessible parts ………………………..:

Double/Reinforced insulation complies with requirements specified in clause 10 and 13.

P

Components bridging double or reinforced insulation complying with 14.1 a) or 14.3 ………………………..:

1) The apparatus have isolating transformer (T1) complies with clause 14.3. 2) Optocouplers (IC2) complies with 14.11.

P

Basic insulation bridged by components complying with 14.3.4.3. …………………………………………...:

No such capacitors. N

Basic and supplementary insulation each being bridged by a capacitor complying with 14.2.1 a) ……:

No such capacitors. N

Double or reinforced insulation being bridged with 2 capacitors in series complying with 14.2.1 a) ……….:

No such capacitors. N

Double or reinforced insulation being bridged with a single capacitor complying with 14.2.1 b) ……………:

Y1 capacitor (CY1) is approved component which complied with IEC 60384-14 / 1993.

P

8.7 This clause is void ……………………………………..: —

8.8 Basic or supplementary insulation > 0,4 mm (mm) ...: No such insulation used. N

Page 11:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 11 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

Reinforced insulation > 0,4 mm (mm) ……………….: 1) Approved sources of optocouplers are used. All sources provided distance of at least 0.4mm. 2) Thickness of transformer bobbin is min. 0.5mm.

P

Thin sheet insulation (excluding non-separable thin sheet insulation. See 8.22) ……………………………:

No used. N

Basic or supplementary insulation, at least two layers, each meeting 10.3 ………………………….....:

No used. N

Basic or supplementary insulation, three layers any two of which meet 10.3 ……………………………......:

No used. N

Reinforced insulation, two layers each of which meet 10.3 ……………………………………………………...:

No such insulation used. N

Reinforced insulation, three layers any two which meet 10.3 ……………………………………………….:

3 layers tape on isolating transformer body (T1).

P

8.9 Adequate insulation between internal hazardous live conductors and accessible parts ……………………..:

Reinforced insulation. P

Adequate insulation between internal hazardous live parts and conductors connected to accessible parts ……………………………………………………:

Single insulated but safely anchored.

P

Double insulation between conductors connected to the mains and accessible parts. ……………………...:

Refer below P 8.10

Double insulation between internal hazardous live parts and conductors connected to accessible parts. ……………………………………………………:

Double or reinforced insulation provided between conductors connected to the mains and accessible parts.

P

8.11 Detaching of wires ……………………………………..:

Refer to below: P

No undue reduction of creepages or clearance distances if wires become detached …………………:

No wire could be become detached.

P

Vibration test carried out ………………………………:

N

8.12 This clause is void ……………………………………..: — 8.13 Adequate fastening of windows, lenses, lamp covers

etc. (pull test 20 N for 10 s) …………………………...:No such parts used. N

Page 12:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 12 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

8.14 Adequate fastening of covers (push/pull test 50 N for 10 s) ……………………………………………………..:

No such cover used. N

8.15 No risk of damage to the insulation of internal wiring due to hot parts or sharp edges ………………………:

No risk of damage to insulation due to high temperature, sharp edges or pinches.

P

8.16 Only special supply equipment can be used ……......: No special supply apparatus used.

N

8.17 Insulated winding wire without additional interleaved insulation ………………………………………………..:

Insulation on winding wires of T1 complies with IEC 60065. See list of critical components.

P

8.18 Endurance test as required by 8.17 ………………….: Test not required. N 8.19 Disconnection from the mains See below P 8.19.1 Disconnect device …………………………………......: The plug will be acting as

disconnect device and compliance with 5.4.2.

P

All-pole switch or circuit breaker with >3mm contact separation ………………………………………………:

No such part used. N

8.19.2 Mains switch ON indication …………………………...:

No such device. N

8.20 Switch not fitted in the mains cord ……………………:

No such device. N

8.21 Bridging components comply with clause 14 ………..:

No bridging components are used for bridging gaps of switch conductively connected to the mains.

N

8.22 Non-separable thin sheet material …………………...: No such part used. N

9 Electric shock hazard under normal operating conditions P 9.1 Testing on the outside See below: P 9.1.1 For voltages >1000 V ac or >1500 V dc complies

with clause 13.3.1 for basic insulation ……………….:No such high voltage provided. N

9.1.1.1 a) Open circuit voltages ……………………………….: For output connector: Max. 13.2Vdc.

P

b) Touch current measured from terminal devices using the network in annex D …………………………:

Measured location: Main poles and output connector. (see appended table 9.1.1)

P

c) Discharge not exceeding 45 μC …………………...:

The discharge didn’t exceed 45μC.

P

Page 13:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 13 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

d) Energy of discharge not exceeding 350 mJ ……...:

No part with stored voltages exceeding 15kV.

N

9.1.1.2 Test with test finger and test probe …………………...:

No access to hazardous live parts.

P

9.1.2 No hazardous live shafts of knobs, handles or levers ……………………………………………………:

No live shafts, handles or levers. N

9.1.3 Ventilation holes and other holes tested by means of 4 mm x 100 mm test pin ………………………………:

No openings. N

9.1.4 Terminal devices tested with 1 mm x 20 mm test pin (10 N); test probe D of IEC 61032 ……………………:

No terminal. N

Terminal devices tested with 1 mm x 100 mm straight wire (1 N); test probe D of IEC 61032 ………:

N

9.1.5 Pre-set controls tested with 2.5 mm x 100 mm test pin (10 N); test probe C of IEC 61032 ……………….:

No pre-set controls used. N

9.1.6 No shock hazard due to stored charge on withdrawal of the mains plug; voltage (V) after 2 s ………………:

No X capacitor provided. The normal capacitance across the mains poles does not exceed 0.1μF

N

If C is not greater than 0,1 μF no test needed ………: N 9.1.7 Resistance to external forces No damage to the enclosure. P a) Test probe 11 of IEC 61032 for 10 s (50 N) ……...: Test with test finger results in no

hazard. P

b) Test hook of fig. 4 for 10 s (20 N) …………………: Test with test hook results in no hazard.

P

c) 30 mm diameter test tool for 5 s (100 or 250 N) …: Test with 250N results in no damage.

P

9.2 No hazard after removing a cover by hand ………….:

No cover removable by hand. N

10 Insulation requirements P 10.1 Insulation resistance (MΩ) at least 2 MΩ min. after

surge test for basic and 4 MΩ min. for reinforced insulation ………………………………………………..:

>20MΩ (Surge test is performed between primary circuits and secondary output circuits)

P

10.2 Humidity treatment 48 h or 120 h …………………….: Performed for 120 h at temp. 40oC and a relative humidity 95%

P

Page 14:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 14 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

10.3 Insulation resistance and dielectric strength between mains terminals ………………………………………...:

See appended table 10.3. P

Insulation Resistance and dielectric strength across BASIC or SUPPLEMENTARY insulation (Class 1) …:

N

Insulation resistance and dielectric strength across REINFORCED insulation (Class II) …………………..:

See appended table 10.3. P

11 Fault conditions P 11.1 No shock hazard under fault condition ………………: No electric shock hazard under

fault conditions. P

11.2 Heating under fault condition ………………………….:

See below. P

Flames extinguish within 10 seconds ......................:

Neither danger of fire to surroundings nor abnormal heat developed.

P

No hazard from softening solder …………………...: Considered. P Soldered terminations not used as protective

mechanism ……………………………………………..:No soldered terminations used. P

11.2.1 Measurement of temperature rises …………………..: See appended table 11.2. P 11.2.2 Temperature rise of accessible parts ……………...: See appended table 11.2. P 11.2.3 Temperature rise of parts, other than windings,

providing electrical insulation …………………………:See appended table 11.2. P

Temperature rise of printed circuit boards (PCB) exceeding the limits of table 3 by max. 100 K for max. 5 min ……………………………………………...:

Temp. rise of PCB do not exceed limits of table 3.

P

a) Temperature rise of printed circuit boards (PCB) to 20.1.3, exceeding the limits of table 3 by not more than 100 K for an area not greater than 2 cm² ………:

Temp. rise of PCB do not exceed limits of table 3.

P

b) Temperature rise of printed circuit boards (PCB) to 20.1.3 up to 300 K for an area not greater than 2 cm² for a maximum of 5 min ……………………………….:

Temp. rise of PCB do not exceed limits of table 3.

P

Meets all the special conditions if conductors on printed circuit boards are interrupted ………………...:

No conductors are interrupted / peeled / loosened during fault conditions

P

Page 15:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 15 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

Class I protective earthing maintained ……………….:

Class II apparatus. N

11.2.4 Temperature rise of parts acting as a support or mechanical barrier ……………………………………..:

See appended table 11.2. P

11.2.5 Temperature rise of windings …………………………:

See appended table 11.2. P

11.2.6 Temperature rise of parts not subject to the limits of 11.2.1 to 11.2.5 ………..………………………………:

No excessive temperature observed/measured on other parts. (see appended table 11.2)

P

12 Mechanical strength P 12.1.1 Bump test where mass >7 kg ………………………...: Mass < 7 kg. N 12.1.2 Vibration

test ……………………………………………: No applicable. N

12.1.3 Impact hammer test …………………………………...: No damage in the sense of this standard.

P

Steel ball test …………………………………………...:

No damage in the sense of this standard.

P

12.1.4 Drop test for portable apparatus where mass ≤ 7 kg ……………………………………………...........:

No damage in the sense of this standard.

P

12.1.5 Thermoplastic enclosures stress relief test ………….:

Test is carried out at 94°C / 7h. No risk of shrinkage or distortion on enclosures due to release of internal stresses.

P

12.2 Fixing of knobs, push buttons, keys and levers ……..:

No knobs, push buttons, keys and levers.

N

12.3 Remote controls with hazardous live parts ………….: No remote control. N 12.4 Drawers (pull test 50 N,

10 s) …………………………: No drawers. N

12.5 Antenna coaxial sockets providing isolation …………:

No antenna socket which isolated hazardous live parts from accessible parts.

N

12.6 Telescoping or rod antennas construction ….……….:

No telescoping or rod antenna. N

12.6.1 Telescoping or rod antennas securement ………......: No telescoping or rod antenna. N

Page 16:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 16 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

13 Clearances and creepage distances P 13.1 Clearances in accordance with

13.3 …………………: See 13.3 P

Creepage distances in accordance with 13.4 ……….:

See 13.4 P

13.2 Determination of operating voltage ……………..……: The rms and peak voltage of the appliance is mains voltage 240V max. The unit was connected to a 240V TN power system. The highest operating voltages are measured on transformers (T1). (appended table 13.2)

P

13.3 Clearances Refer to below. P 13.3.1 General …………………………………………………: Clearance distances are in

compliance with table 8, 9. (see appended table 13.3 and 13.4)

P

13.3.2 Circuits conductively connected to the mains comply with table 8 and, where applicable, table 9 …………..:

(see appended table 13) P

13.3.3 Circuits not conductively connected to the mains comply with table 10 …………………………………...:

(see appended table 13) P

13.3.4 Measurement of transient voltages …………………..:

No used. N

13.4 Creepage distances …………………………………...: Creepage distances are in compliance with table 11. (see appended table 13).

P

Creepage distances greater than table 11 minimum values …………………………………………………...:

None N

13.5 Printed boards P 13.5.1 Clearances and creepage distances between

conductors on printed circuit boards, one of which may be conductively connected to the mains, as in fig. 10 ……………………………………………………:

(see appended table 13) P

13.5.2 Type B coated printed circuit boards complying with IEC 60664-3 (basic insulation only) …………………..:

No coated PCB. N

Page 17:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 17 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

13.6 Conductive parts along uncemented joints clearances and creepage distances comply with 13.3 and 13.4 ………………………………………..............:

No uncemented joints. N

Conductive parts along reliably cemented joints comply with 8.8 …………………………………………:

N

Temperature cycle test and dielectric strength test …:

N

13.7 Enclosed, enveloped or hermetically sealed parts not conductively connected to the mains, clearances and creepage distances as in table 12 ……………………:

No such part used. N

13.8 Parts filled with insulating compound, meeting the requirements of 8.8 ……………………………………:

Optocoupler (IC2) is approval component, see list of critical components.

P

14 Components P 14.1 Resistors See below: P a) Resistors between hazardous live parts and

accessible metal parts …………………………………:

No such resistors used. N

b) Resistors, other than between hazardous live parts and accessible parts …………………………………..:

No such resistors used. N

Resistors separately approved ……………………….: N 14.2 Capacitors and RC units See below. P Capacitors separately

approved ………………...……: Yes, see below. P

14.2.1 Y capacitors tested to IEC 60384-14, 2nd edition ……:

Capacitor (CY1) is Y1 type, see list of critical components.

P

14.2.2 X capacitors tested to IEC 60384-14, 2nd edition ……:

No such capacitors used. N

14.2.3 Capacitors operating at mains frequency but not connected to the mains: tests for X2 …………………:

No such capacitors used. N

14.2.5 Capacitors with volume exceeding 1750 mm³, where short-circuit current exceeds 0,2 A: compliance with IEC60384-1, 4.38 category B or better ………………:

Compliance due to high short circuit current not relevant because of fuse F1.

P

Page 18:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 18 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

Capacitors with volume exceeding 1750 mm³, mounted closer to a potential ignition source than table 5 permits: compliance with IEC 60 384-1, 4.38 category B or better ……………………………………:

C1, C2 with metal housing. P

Shielded by a barrier acc. to 20.1.4/ table 21 or metal …………………………………………………….:

No barrier required, see above. N

14.3 Inductors and windings See below. P Comply with IEC 61558-1, IEC 61558-2

(as relevant) and clause 20.1.4 ……………………….:

Refer to cl.14.3.2. N

14.3.1 Transformers and inductors marked with manufacturer's name and type ……………………….:

See appended table 14. P

Transformers and inductors separately approved ….: No N 14.3.2 General …………………………………………………: Isolating transformers, ref.

Transformers spec. P

Insulation material complies with clause 20.1.4 Insulation material complies with table 21 on flammability class.

P

14.3.3 Constructional requirements See below. P 14.3.3.1 Clearances and creepage distances comply with

clause 13 ………………………………………………..:

Transformer complied with clause 13.

P

14.3.3.2 Transformers meet the constructional requirements .:

Complied, refer to appended table 14.3.3.2.

P

14.3.4 Separation between windings Refer below P 14.3.4.1 Class II transformers have adequate separation

between hazardous live parts and accessible parts (double or reinforced insulation) ……………………...:

Transformer have adequate separation and construction.

P

Coil formers and partition walls > 0,4 mm …………...:

Min. 0.5mm. P

14.3.4.2 Class I transformers, with basic insulation and protective screening only if all 7 conditions of 14.3.4.2 are met ………………………………………………….:

No such transformer used. Windings are of Class II construction.

N

14.3.4.3 Separating transformers with at least basic insulation:

No such transformer used. Windings are of Class II construction.

N

14.3.5 Insulation between HAZARDOUS LIVE parts and ACCESSIBLE parts

Refer below P

Page 19:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 19 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

14.3.5.1 Class II transformers have adequate insulation between hazardous live parts and accessible parts (double or reinforced insulation) ……………………...:

Double or reinforced insulation between hazardous live windings and accessible conductive parts.

P

Coil formers and partition walls > 0,4 mm …………...:

Min. 0.5mm. P

14.3.5.2 Class I transformers have adequate insulation between hazardous live parts and accessible conductive parts or those conductive parts or protective screens connected to a protective earth terminal …………………………………………………:

Windings of Class II construction used.

N

Winding wires connected to protective earth have adequate current-carrying capacity …………………..:

N

14.4 High voltage components ……………………………..:

No high voltage components. N

High-voltage components and assemblies: U > 4 kV (peak) separately approved …………….....................:

N

Component meets category V-1 of IEC 60707 …......: N 14.4.1 High voltage transformers and multipliers tested as

part of the submission …………………………………:

N

14.4.2 High voltage assemblies and other parts tested as part of the submission …………………………………:

N

14.5 Protective devices See below P Protective devices used within their ratings …………: F1 T2AH/250V P External clearances and creepage distances meet

requirement of clause 13 for the voltage across the device when opened ………………………………......:

Fuse is separately approved, between fuse pad 1 to pad 2. Min. 2.6 mm.

P

14.5.1.1 a) Thermal cut-outs separately approved ……………:

No such thermal cut-out. N

b) Thermal cut-outs tested as part of the submission: N 14.5.1.2 a) Thermal links separately

approved ………………..: No thermal links. N

b) Thermal links tested as part of the submission ….: N 14.5.1.3 Thermal devices re-settable by

soldering ……………: No such thermal device N

Page 20:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 20 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

14.5.2.1 Fuse-links in the mains circuit according to IEC 60127 ……………………………………………….......:

Fuse is approved according to IEC 60127, see list of critical components.

P

14.5.2.2 Correct marking of fuse-links adjacent to holder ……:

Fuse marked on PCB adjacent to component as: F1 T2AH/250V

P

14.5.2.3 Not possible to connect fuses in parallel …………….: No fuse holder so designed that fuse-links can be connected in parallel.

N

14.5.2.4 Not possible to touch hazardous live parts when replacing fuse-links without the use of a tool ………..:

No replacement of fuse possible by hand.

N

14.5.3 PTC-S thermistors comply with IEC 60730-1 ……….: No PTC used. N PTC-S devices (15 W) category V-1 or better ………: N 14.5.4 Circuit protectors have adequate breaking capacity

and their position is correctly marked ……………......:Only standard fuse used. N

14.6 Switches (see appended table) No switches. N 14.6.1 a) Separate testing to IEC 61058 including:

- 10 000 operations

- Normal pollution suitability

- Resistance to heat and fire level 3

- Make and break speed independent of speed of

Actuation - V-0 compliance with annex G, G.1.1 ……………...:

N

14.6.1 b) Tested in the apparatus ……………………………….: N Switch controlling > 0.2A with open contact voltage

> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 and V-0 in annex G, G.1.1 …………………………….:

N

Switch controlling > 0.2A with open contact voltage < 35 V (peak)/24 V dc complying with 14.6.3 and V-0 in annex G, G.1.1 …………………………………………:

N

Switch controlling < 0.2A with open contact voltage > 35 V (peak)/24 V dc complying with 14.6.4 and V-0 in annex G, G.1.1 ………………………………………:

N

14.6.2 Switch tested to 14.6.1 b) constructed to IEC 61058-1 subclause 13.1 and has making/breaking action independent of speed of actuation …………………...:

N

Page 21:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 21 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

14.6.3 Switch tested to 14.6.1 b) compliant with IEC 61058-1 subclause 16.2.2 d) and m) not attaining excessive temperatures in use ……………………………………:

N

14.6.4 Switch tested to 14.6.1 b) has adequate dielectric strength ……………………………………………...….:

N

14.6.5 Mains switch controlling mains socket outlets additional tests to IEC 60058-1 ……………………….:

No mains socket outlet. N

Socket outlet current marking correct ………………..:

N

14.7 Safety interlocks No safety interlocks. N Safety interlocks to 2.8 of IEC 60950 ……………......: N 14.8 Voltage setting devices and the

like ………………….: No voltage selector. N

Voltage setting device not likely to be changed accidentally …………………………………………......:

N

14.9 Motors No motor. N 14.9.1 Endurance test on motors …………………………….: N

Motor start test …………………………………………: N

Dielectric strength test …………………………………:

N

14.9.2 Not adversely affected by oil or grease etc. ………...:

N

14.9.3 Protection against moving parts ……………………...: N

14.9.4 Motors with phase-shifting capacitors, three-phase motors and series motors meet clause. B.8, B.9 and B.10 of IEC 60950, Annex B ………………………….:

N

14.10 Batteries No batteries. N 14.10.1 Batteries mounted with no risk of accumulation of

flammable gases ………………………………………: N

14.10.2 No possibility of recharging non-rechargeable batteries …………………………………………………:

No lithium batteries provided. N

14.10.3 Recharging currents and times within manufacturers limits …………………………………………………….:

N

Lithium batteries discharge and reverse currents within the manufacturers limits ……………………….:

N

Page 22:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 22 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

14.10.4 Battery mould stress relief …………………………….:

N

14.10.5 Battery drop test ………………………………………..:

N

14.11 Optocouplers Optocuplers (IC2) is approval component, see list of critical components.

P

Optocouplers comply with Cl. 8 ………………………: P Internal and external dimensions to 13.1. or

alternatively 13.6 (jointed insulation) …………………:

P

14.12 Surge suppression varistors Certified varistor (MOV) is between Line and Neutral (located after fuse). Approved component used, refer to table 14.

P

Comply with IEC 61051-2 ……………………………..:

Approved component used, refer to appended table 14.

P

Not connected between mains and accessible parts except for earthed parts of permanently connected apparatus ……………………………………………….:

N

Complies with the current pulse, fire hazard and thermal stress requirements of 14.12 ………………..:

Approved component used, refer to appended table 14.

P

15 Terminals P 15.1.1 Mains plug, appliance inlet, interconnection couplers

and mains socket-outlet meet the appropriate standard ………………………………………………...:

The main plug complied with appropriate component standard. No mains supply of this unit to other equipment.

P

Overloading of plugs or appliance inlets prevented if the apparatus has mains socket outlets ……………..:

No such parts. N

Overloading of internal wiring prevented if the apparatus has mains socket outlets ………………….:

No such parts. N

15.1.2 Connectors for antenna, earth, audio, video or

data …..........................................................................:

No such parts. N

No risk of insertion in mains socket-outlets ………….:

N

Page 23:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 23 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

No risk of insertion into audio or video: outlets marked with the symbol of 5.2 ….................................:

N

15.1.3 Output terminals of a.c. adaptors or similar devices not compatible with household mains socket-outlets :

No such devices used. N

15.2 Provision for protective earthing Class II apparatus. N Accessible conductive parts of Class I equipment

reliably connected to earth terminal, within equipment

N

Protective earth conductors correctly coloured ……..: N Equipment with non-detachable mains cord provided

with separate protective earth terminal near mains input ….........................................................................:

N

Protective earth terminal resistant to corrosion ……..: N Earth resistance test: < 0,1 Ω at 25 A ……………….: N 15.3 Terminals for external flexible cords and for

permanent connection to the mains supply See below: N

15.3.1 Adequate terminals for connection of permanent wiring ………………………………………………...….:

Apparatus is not for permanent connection.

N

15.3.2 Reliable connection of non-detachable cords ……….:

Direct plug-in apparatus. N

Not soldered to conductors of a printed circuit board : N Adequate clearances and creepage distances

between connections should a wire break away ……:

N

Wire secured by additional means to the

conductor ………………………………………………:

N

15.3.3 Screws and nuts clamping conductors have adequate threads: ISO 261, ISO 262 or similar …….:

No external mains supply conductor used.

N

15.3.4 Soldered conductors wrapped around terminal prior to soldering or held in place by additional means …..:

No terminals used. N

Clamping of conductor and insulation if not soldered or held by screws ………………………………………:

N

15.3.5 Terminals allow connection of appropriate cross-sectional area of conductors, for the rated current of the equipment ………………………………………….:

No terminals used. N

15.3.6 Terminals to 15.3.3 have sizes required by table 16 .: No terminals used. N

Page 24:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 24 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

15.3.7 Terminals clamp conductors between metal and have adequate pressure ………………………………:

No terminals used. N

Terminals designed to avoid conductor slipping out when tightened or loosened …………………………..:

N

Terminals adequately fixed to avoid loosening when the clamping is tightened or loosened and stress on internal wiring is avoided ...………………...................:

N

15.3.8 Terminals carrying a current more than 0,2 A: contact pressure not transmitted by insulating material except ceramic ………………………………………………….:

No terminals used. N

15.3.9 Termination of non-detachable cords: wires terminated near to each other ………………………...:

No terminals used. N

Terminals located and shielded: test with 8 mm strand ……………………………………………………:

N

15.4 Devices forming a part of the mains plug See below. P

15.4.1 No undue strain on mains socket-outlets ……………: Max. 0.083Nm<0.25Nm P

15.4.2 Device complies with standard for dimensions of mains plugs …………………………………………….:

The EU plug complies with the relevant standard, others plug should be evaluated when marketing.

P

15.4.3 Device has adequate mechanical strength (tests a,b,c) …………………………………………………….:

Compliance. P

16 External flexible cords N 16.1 Mains cords sheathed type, complying with

IEC 60227 for PVC or IEC 60245 for synthetic rubber cords …………………………………………………….:

Not provided. N

Non-detachable cords for Class I have green/yellow core for protective earth ……………………………….:

N

Page 25:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 25 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

16.2 Mains cords conductors have adequate cross-sectional area for rated current consumption of the equipment ………………………………………………:

Not provided. N

16.3 a) Flexible cords not complying with 16.1, used for interconnections between separate units of equipment used in combination and carrying hazardous live voltages, have adequate dielectric strength …………………………………………………:

Not provided. N

b) Flexible cords not complying with 16.1, withstand bending and mechanical stress (3.2 of IEC 60227-2):

N

16.4 Flexible cords used for connection between equipment have adequate cross-sectional areas to avoid temperature rise under normal and fault conditions ……………………………………………….:

Not provided. N

16.5 Adequate strain relief on external flexible cords …….:

Not provided. N

Not possible to push cord back into equipment ……..:

N

Strain relief device unlikely to damage flexible

cord ...……………………………………………………:

N

For mains cords of Class I equipment, hazardous live conductors become taut before earth conductor ……:

N

16.6 Apertures for external flexible cord: no risk of damage to the cord during assembly or movement in use ………………………………………………………:

Not provided. N

16.7 Transportable musical instruments and amplifiers fitted with detachable cord set with appliance inlet to IEC 60320-1 ……………………………………………:

Not transportable musical instruments or associated amplifier.

N

Transportable musical instruments and amplifiers fitted with detachable cord sets or with means of stowage to protect the cord …………………………...:

N

17 Electrical connections and mechanical fixings P 17.1 Torque test to table 20 No screw. N

- screws into metal: 5 times …………………………...:

N

Page 26:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 26 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

- screws into non-metallic material: 10 times ………..:

2.4 mm for fixing plactic enclosure and 0.4Nm at 10 times.

P

17.2 Correct introduction into female threads in non-metallic material ………………………………………..:

Correct introduction of screws. P

17.3 Cover fixing screws: captive …………………………..:

Non-captive screws used, see below

P

Non-captive fixing screws: no hazard when replaced by a screw whose length is 10 times its diameter …..:

Non-captive fixing screws used, it will not cause a reduction of clearance and creepage distance.

N

17.4 No loosening of conductive parts carrying a current > 0,2 A …………………………………………………..:

No such screw. N

17.5 Contact pressure not transmitted through plastic other than ceramic for connections carrying a current > 0,2 A …………………………………………………..:

No such screw. N

17.6 Stranded conductors of flexible supply cords carrying a current > 0,2 A with screw terminals not consolidated by solder …………………………………:

No screw terminal. N

17.7 Cover fixing devices other than screws have adequate strength and their positioning is unambiguous …………………………………………...:

Cover fixing by screw and snap fastener, after 10 times removed and replace, the apparatus compliance with 9.1.7 a) and b)

P

17.8 Fixing devices for detachable legs or stands

provided …………………………………………………:

No such parts. N

17.9 Internal pluggable connections, affecting safety, unlikely to become disconnected ……………………..:

Connections complies, checked by inspection

P

18 Mechanical strength of picture tubes and protection against the effects of implosion

N

Picture tube separately approved to IEC 61965 …….:

No picture tube used. N

Picture tube separately approved to 18.1 ..…….…….:

N

Page 27:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 27 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

18.1 Picture tubes >16 cm intrinsically protected ……...….:

N

Non-intrinsically protected tubes >16 cm used with protective screen ..…………………………………......:

N

Protective film as part of implosion protection: edges covered by enclosure ..……………………………...…:

N

18.2 Intrinsically protected tubes: tests on 12 samples …..:

N

18.2.1 Samples subject to ageing: 6 samples ………………: N 18.2.2 Samples subject to implosion test: 6

samples ………: N

18.2.3 Samples subject to mechanical strength test (steel ball): 6 samples ..……………………………………….:

N

18.3 Non-intrinsically protected tubes tested to 18.3 ……..:

N

19 Stability and mechanical hazards P Mass of the equipment exceeding

7 kg ..…………….: Mass < 7 kg. N

Apparatus intended to be fastened in place – suitable instructions ………………………………………….….:

N

19.1 Test on a plane, inclined at 10o to the horizontal …....:

N

19.2 100 N force applied vertically downwards ..………….:

N

19.3 100 N force, or 13% of weight, applied horizontally to point of least stability ….……………………………….:

N

19.4 Edges or corners not hazardous …………………......:

There is no hazardous edges or corners.

P

19.5 Glass surfaces (exc. laminated) with an area exceeding 0,1 m² or maximum dimension > 450 mm, pass the test of 19.5.1 …………………………………:

No glass surface. N

19.6 Wall or ceiling mountings adequate ………………….: Not wall or ceiling mounting. N

Page 28:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 28 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

20 Resistance to fire P 20.1 Electrical components and mechanical parts See below: P a) Exemption for components contained in an

enclosure of material V-0 to IEC 60695-11-10 with openings not exceeding 1 mm in width ………………:

The apparatus enclosure is made of V-0 (UL approval). No flammability requirements for the internal components. No openings provided.

P

b) Exemption for small components as defined in 20.1 ……………………………………………………...:

PCB is flammability class V-1, and except is made for metal enclosure.

P

20.1.1 Electrical components meet the requirements of Clause 14 or 20.1.4 …………………………………....:

Electrical components comply with flammability requirements in clause 14.

P

20.1.2 Insulation of internal wiring working at voltages > 4 kV or leaving an internal fire enclosure, or located within the areas mentioned in Table 21, not contributing to the spread of fire ……………………...:

No wires wiring working at voltages > 4 kV.

N

20.1.3 Material of printed circuit boards on which the available power exceeds 15 W at a voltage between 50 V and 400 V (peak) a.c. or d.c. meets V-1 or better to IEC60707, unless used in a fire enclosure ..:

The PCB is of base material with flammability category V-1 (UL approval). See List of Critical Components.

P

Material of printed circuit boards on which the available power exceeds 15 W at a voltage >400 V (peak) a.c. or d.c. meets V-0 to IEC 60707 ………….:

The PCB is of base material with flammability category V-1 (UL approval) and enclosure is made a V-0. See List of Critical Components.

N

20.1.4 Components and parts not covered by 20.1.1, 20.1.2 and 20.1.3 (other than fire enclosures) mounted nearer to a potential ignition source than the distances in Table 21 comply with the relevant flammability category in Table 21 …………………….:

Transformer bobbin and large capacitor. See appended table 14.

P

Components and parts as above but shielded from a potential ignition source, with the barrier area in accordance with Table 21 and fig. 13 ………………..:

No shield required. N

Apparatus with voltages >4kV under normal operating conditions and distances to the enclosure exceed those specified Table 21, flammability classification HB40 or better is required for the enclosure …………………………………………..…...:

No voltages >4kV. N

20.2 Fire enclosure No voltage >4 KV. N

Page 29:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 29 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

20.2.1 Potential ignition sources with open circuit voltage > 4 kV (peak) a.c. or d.c. contained in a fire enclosure to V-1 ………………………………………..:

N

20.2.2 Internal fire enclosures with openings not exceeding 1 mm in width and with openings for wires completely filled ……………………………………………………..:

No internal fire enclosure. N

20.2.3 Requirements of 20.2.1 and 20.2.2 met by an internal fire enclosure ……………………………….:

No internal fire enclosure. N

A Annex A, Additional requirements for apparatus with protection against splashing water

N

A.5 Marking and instructions N A.5.1 j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not

apply ………………………………………………….....:

N

A.10.2 Insulation requirements N A.10.2.1 Enclosure provides protection against splashing

water ...........................................................................: N

A.10.2.2 Humidity treatment carried out for 7 days ……………:

N

B Annex B, Apparatus to be connected to the TELECOMMUNICATION NETWORKS N Complies with IEC 62151 clause 1 …………………..: Not connected to

telecommunication network. N

Complies with IEC 62151 clause 2 …………………..: N Complies with IEC 62151 clause 3 but with 3.5.4

modified to 2.4.10 of this standard ………………...…: N

Complies with IEC 62151 clause 4 but with 4.1.2, 4.1.3 and 4.2.1.2 modified in accordance with annex B of this standard ………………………………………:

Complies with IEC 62151 cause 5 but with 5.3.1 modified in accordance with annex B of this

standard ……………………………………………...…:

Complies with IEC 62151 clause 6 …………………..: N Complies with IEC 62151 clause

7 …………………...: N

Page 30:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 30 of 40 -

Report No. 125414

IEC 60065 Clause Requirement – Test Result - Remark Verdict

TRF No. IEC60065_I

Complies with IEC 62151 annex A, B and C ………...:

N

L Annex L, Additional requirements for electronic flash apparatus for photographic purposes

N

L. 5 Marking and instructions N L. 5.4 Instructions for battery chargers and Supply

apparatus indicating type or model number of flash apparatus with which it is to be used …………………:

N

Instructions for flash apparatus indicating type or model number of battery chargers or Supply apparatus with which it is to be used …………………:

N

L. 7 Heating under normal operating conditions N L7.1.5 &

L11.2.6

Lithium batteries meet permissible temp rise in Table 3 , unless comply with 6.2.2.1.or 6.2.2.2 of IEC 60086-4 ………………………………………………....:

N

L. 9 Electric shock hazard under normal operating conditions N L. 9.1.1 Terminals to connection to synchroniser not

HAZARDOUS LIVE ……………………………………:

N

L.10 Insulation requirements N L. 10.3.2 High frequency pulse ignition ………………………..: N L. 12 Mechanical strength N L. 12.1.3 Windows for flash tubes are excluded from steel ball

impact test ……………………………………………...: N

L. 14 Components N L14.6.6 Mains switch characteristics appropriate to its

function under normal conditions …………………….: N

L. 20 Resistance to fire N L. 20.1 c) Trigger coil for discharge purpose is not considered

to be a POTENTIAL IGNITION SOURCE …………..: N

Page 31:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 31 of 40 -

Report No. 125414

TRF No. IEC60065_I

7.1 TABLE: temperature rise measurements P

Power consumption in the OFF/Stand-by position of the functional switch (W)

No Stand-by function. N

Operating conditions

Un (V) In (A) Pn (W) Pout (W)

90V/50Hz 0.396 21.2 --

90V/60Hz 0.400 21.2 --

100V/50Hz 0.366 21.2 --

100V/60Hz 0.371 21.2 --

240V/50Hz 0.191 21.2 --

240V/60Hz 0.189 21.2 --

254V/50Hz 0.185 21.5 --

254V/60Hz 0.184 21.5 --

264V/50Hz 0.181 21.6 --

264V/60Hz 0.179 21.6 --

Loudspeaker impedance (Ω) .................................. : —

Several loudspeaker systems —

Marking of loudspeaker terminals N

Page 32:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 32 of 40 -

Report No. 125414

TRF No. IEC60065_I

Monitored point: dT (K) Permitted

dT (K) Applied voltage and position of the unit 90V/50Hz

horizontal 90V/50Hz

vertical 264V/50Hz horizontal

264V/50Hz vertical

--

Plug holder 8.4 8.7 8.1 10.6 60 Primary lead wire 24.5 28.4 21.8 22.4 35 MOV body 25.0 29.1 20.6 21.6 -- L1 coil 35.6 40.1 27.5 27.7 50 PCB under BD1 39.3 43.5 30.7 30.4 60 C1 body 32.8 36.9 28.5 28.3 60 C2 body 31.5 34.6 31.7 30.0 60 PCB under Q1 49.9 51.7 56.8 49.1 60 T1 coil 46.8 46.2 61.2 52.4 75 T1 core 45.5 45.2 60.6 52.2 75 IC2 body 39.1 37.2 48.6 39.7 55 CY1 body 42.8 44.0 49.7 45.2 55 PCB under D4 49.2 48.6 58.3 52.5 60 Output cord 32.4 30.7 33.5 33.8 35 Enclosure (inside) near T1 29.7 30.4 37.5 33.0 -- Enclosure (outside) near T1 12.9 13.4 14.2 13.3 50 Ambient 45.7 45.3 45.8 45.3 supplementary information: Max. Ambient is 45°C. Temperature limits include less 10K for thermocouple measurement method. If no limit is stated, temperature is for reference only. *) Limited dT (K) is considered (moderate climate is considered, corresponding to an ambient of 45°C).

Page 33:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 33 of 40 -

Report No. 125414

TRF No. IEC60065_I

7.2 TABLE: softening temperature of thermoplastics P Temperature T of part T - normal con-

ditions (oC) T - fault condi-

tions (oC) Min T softening

(oC)

Plug holder, type SE1X(GG)(f1) 55.9°C at ambient= 45.3°C

39.0°C at ambient= 26.0°C

150

supplementary information:

Bobbin of other transformer or choke are made of phenolic. 9.1.1 TABLE: touch current expressed as voltages U1 and U2 in Annex D P Location Measured U1

V (peak) Measured U1 V (DC)

Measured U2 V (peak)

Limits : U1 Max 35V (peak) U1 Max 1.0V (DC) U2 Max 0.35V (peak)

Line phase and output connector

0.67 -- 0.32 Pass

Neutral phase and output connector

0.67 -- 0.32 Pass

Line phase and plastic enclosure (with foil)

0.21 -- 0.12 Pass

Neutral phase and plastic enclosure (with foil)

0.21 -- 0.12 Pass

supplementary information:

Bridging capacitor is rated to max. according to list of critical components. 10.3 TABLE: insulation resistance measurements P Insulation resistance R between: R (MΩ) Required R (MΩ)

Between poles of the circuit directly connected to the mains (primary fuse disconnected)

>20MΩ 2

Between parts separated by double or reinforced insulation: Mains poles and sec. parts

>40MΩ 4

supplementary information:

Page 34:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 34 of 40 -

Report No. 125414

TRF No. IEC60065_I

10.3 TABLE: electric strength measurements P Test voltage applied between: Test voltage (V) Breakdown Between poles of the circuit directly connected to the mains (primary fuse disconnected)

2120Vdc No

Between parts separated by double or reinforced insulation: Mains poles and secondary parts.

4240Vdc No

Between parts separated by double or reinforced insulation: Mains poles and enclosure with foil.

4240Vdc No

supplementary information:

11.2 TABLE: summary of fault condition tests P

Voltage (V) 0,9 or 1,1 times rated voltage ............. : 264V —

Ambient temperature (oC) ....................................... : See below — Monitored point:

Under fault conditions specified below

dT (K) Permitted dT (K)

BD1 s-c 1) 1 sec Fuse opened immediately, no damaged, no hazards.

--

C1 s-c 1) 1 sec Fuse opened immediately, no damaged, no hazards.

--

IC1 (2-3)

s-c 0.18 2 hrs Normal operation, no damaged, no hazards.

T1 coil = 53.3K, ambient =25.9°C

130*)

Q1 (G-S)

s-c 0.01 10 min. Unit shut down, no damage, no hazards.

--

Q1 (G-D)

s-c 1) 1 sec Fuse opened immediately, no damaged, no hazards.

--

Q1 (D-S)

s-c 1) 1 sec Fuse opened immediately, no damaged, no hazards.

--

R4 s-c 0.18 2 hrs Normal operation, no damaged, no hazards.

T1 coil = 53.3K, ambient =25.9°C

130*)

IC2 (1-2)

s-c 0.01 10 min. Unit shut down, no damage, no hazards.

--

IC2 (3-4)

s-c 0.01 10 min. Unit shut down, no damage, no hazards.

--

Page 35:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 35 of 40 -

Report No. 125414

TRF No. IEC60065_I

Monitored point:

Under fault conditions specified below

dT (K) Permitted dT (K)

IC2 (1)

o-c 0.01 10 min. Unit shut down, no damage, no hazards.

--

IC2 (3)

o-c 0.01 10 min. Unit shut down, no damage, no hazards.

--

T1 (2-4)

s-c 0.01 10 min. Unit shut down, no damage, no hazards.

--

T1 (9-10)

s-c 0.01 10 min. Unit shut down, no damage, no hazards.

--

Output s-c 0.01 10 min. Unit shut down, no damage, no hazards.

--

Output o-l 0.23 6.0 hrs Unit oscliiated. Output loaded at 1.6A. No damage, no hazards.

T1 coil = 70.7, ambient = 26.0oC

130 *)

Winding temperature rise measurements

Ambient temperature t1 (oC) ................................... : —

Ambient temperature t2 (oC) ................................... : —

supplementary information:

S-c: short circuit, o-l: overload, o-c: open circuit.

1) Fuse current is more than fuse rating times 2.1. Electric shock hazards measurement as clause 9 on each fault condition, the value does not exceed the limite of clause 11.1. *) Limited dT (K) is considered (moderate climate is considered, corresponding to an ambient of 45°C).

Page 36:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 36 of 40 -

Report No. 125414

TRF No. IEC60065_I

13 TABLE: clearances and creepage distances P

Rated supply voltage: 240V Pollution degree: II Material Group: llla + IIIb

2 N force on internal parts applied: Compliance

30 N force on outside of conductive enclosure applied: Compliance Location

Operating Voltage

Clearance (mm)

Creepage

(mm)

V peak

V rms

Min.

Actual

Min.

Actual

Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below. Basic: Line – Neutral before fuse 339 240 2.0 3.4 2.5 3.4 Basic: F1, pad 1 – 2 339 240 2.0 2.6 2.5 2.6 Reinforced: CY1(prim.) – CY1 (sec.) 376 235 4.0 7.2 5.0 7.2 Reinforced:T1 (prim.) – T1 (sec.) 488 291 4.2 9.0 6.4 9.0 Reinforced: IC2 (prim.) – IC2 (sec.) 344 213 4.0 6.4 5.0 6.4 Reinforced: Components (prim.) – enclosure (sec.)

339 240 4.0 7.0 5.0 8.0

Notes: - Glue add Line/nertual wires and output wires, pass 2 N force. "Min" = minimum required. "Actual = Actual dimensions measured. 1) Trace under transformer (T1).

13.2 TABLE: Operating voltage measurement P Location Peak voltage (V) RMS voltage (V) Comments T1 Pin 1-9 424 235

T1 Pin 1-10 376 234

T1 Pin 2-9 352 208

T1 Pin 2-10 336 206

T1 Pin 3-9 472 277

T1 Pin 3-10 488 291 Max. Vpeak and rms Value

T1 Pin 4-9 344 206

T1 Pin 4-10 372 207

IC2 Pin 1-3 344 213 Max. Vpeak and rms Value

IC2 Pin 2-3 344 212

IC2 Pin 1-4 344 212

IC2 Pin 2-4 344 213

CY1 Pin 1-2 376 235

Page 37:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 37 of 40 -

Report No. 125414

TRF No. IEC60065_I

supplementary information:

14.3.3.2 TABLE: Transformers construction P Loc. Tested insulation Operat-

ing voltage peak / V (13.2)

Operat-ing voltage rms / V (13.2)

Min. electric strength / V (10.3)

Min. clearance / mm (13.3)

Min. creepage distance / mm (13.4)

Min. insu. / mm; number of layers (8.8)

T1 Core - Secondary pins 488 291 3000V ac 4.2 6.4 2 layers min. or 0.4 mm

Loc.

Tested insulation Test voltage/ V

Actual clearance / mm

Actual creepage dist./ mm

Actual insu. / mm; number of layers

T1 Core - Secondary pins 3000V ac 7.0 7.0 *) Supplementary information: *) Secondary windings are triple insulated, ref. list of critical components. The creepage distance from prim. winding to core is 0mm. Core is considered as pri, part.

Page 38:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 38 of 40 -

Report No. 125414

TRF No. IEC60065_I

14 TABLE: list of critical components and materials P

Component Manufacturer/ trademark

Type/model Value / rating Standard Approval/ Reference

CE Plug Eastern Frontier Co., Ltd.

EFS01301000130CE

2.5A, 250Vac IEC60884-1, EN50075

Tested in the equip.

Enclosure Bayer Materialscience AG

6485 V-0 min., 1.5 mm thick min., 115ºC min.

UL94 UL

Plug holder Sabic Innovative Plastics China Co., Ltd.

SE1X(GG)(f1) V-1 min., 1.5 mm thick min., 105ºC min.

UL94 UL

Fuse (F1) XC Electronics (Shenzhen)

3T-Series T2AH, 250Vac IEC/EN 60127-1, IEC/EN 60127-3

VDE

Varistor (MOV) (Optional) *)

Thinking Lien Shun

TVR14471 14D471K

350Vac UL1449, IEC61051-1, IEC61051-2

UL, VDE UL, VDE

Choke (L1) (Optional) No bobbin

Eastern Frontier EFT-00182 105 °C -- Tested in the equip.

Bridge Diode (BD1)

Various Various 0.8A, min. 600Vac

-- Tested in the equip.

Bulk capacitor (C1)

Various Various Min 15μF, min. 400V, min. 105°C

-- Tested in the equip.

MOSFET (Q1)

Various Various Min. 4A, min, 600V

-- Tested in the equip.

Bridge-Caps. (CY1) (Optional)

TDK Jyh Chung Vishay Matsushita Success Murata Haohua

CD JD VY1, WKP NS-A SE, SB KX CT 7

Max.2200pF, Min. 250Vac, 100°C, Y1 type

IEC60384-14 2 ed., UL1414

VDE, UL VDE, UL VDE, UL VDE, UL VDE, UL VDE, UL VDE, UL

Optocoupler (IC2)

Cosmo Vishay Bright Led Fairchild Lite-On

K1010, KPC817TCET110X series BPC-817 H11A817X LTV-816., LTV817….

See appended opto electronic devices Min. 100°C

IEC 60950-1, UL 1577

VDE, UL VDE, UL VDE, UL VDE, UL VDE, UL VDE, UL

Transformer (T1) 1) Triple insul. wire

Eastern Frontier Furukawa

EFT-00181 TEX-E

Class B 130°C

IEC60065 Clause 14.3 IEC/EN60950-1 2)

Tested in the equip. VDE

PCB Various Various V-0, min. 105°C UL 796

UL

Page 39:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 39 of 40 -

Report No. 125414

TRF No. IEC60065_I

Component Manufacturer/ trademark

Type/model Value / rating Standard Approval/ Reference

1) an asterisk indicates a mark which assures the agreed level of surveillance Supplementary information: *) Varistor complies with UL 1449 3ed type 3 which cover the required 15 combination pulses 6kV (1.2/50s)/ 3kA (8/20s) test this is more strict than table I group 1 of IEC 61051-2. 1) For bobbin and others material of transformers, refer to transformer specification. 2) No difference between IEC 60950-1 Annex U and IEC 60065 Annex H.

Page 40:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 40 of 40 -

Report No. 125414

TRF No. IEC60065_I

Appended OPTO ELECTRONIC DEVICE 14.11 P

Manufacturer Cosmo / Cosmo / Vishay / Bright Led / Fairchild / Lite-On

Type K1010 / KPC817 / TCET110X series / BPC-817 / H11A817X /

LTV-816. / LTV817….

Separately tested Tested by FIMKO

Connected over insulation Reinforced insulation

External creepage distance 8.0 / 8.0 / 8.4 / 7.6 / >7 / 7.8 mm

Internal creepage distance 5.3 / 5.3 / 4.7 / 7.6 / -*) / 5.2 mm

Distance through insulation 0.5 / 0.5 / 0.6 / 0.5 / >1 / 0.8 mm

Tested under the following

conditions

R, S, B

Input

Output

Comments - *) There is not any internal distance. Test according to IEC60950-1, cl. 2.10.8 has been carried out ten times for components at 100 °C / 25 °C / 0 °C / 25 °C. Humidity treatment of 48 h as well as electric strength tests at 3000 V / 1 min. and 5000 V / 1 min. were carried out to the component after thermal cycling test.

Page 41:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

IEC60065(ed.7); am.1 (2005) - Page 1 of 9 -

www.nemko.com Report No. 125414

IEC60065 - ATTACHMENT

Clause Requirement + Test Result - Remark Verdict

ATTACHMENT TO TEST REPORT IEC 60065 EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES

Audio, video and similar electronic apparatus – Safety requirements Differences according ....................: EN 60065:2002 + A1:2006

Attachment Form No......................: EU_GD_IEC60065I Attachment Form Originator ........................... : Intertek Semko AB

Master Attachment Form ................................ : 2008-05

Copyright © 2008 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved.

IEC 60065, GROUP DIFFERENCES (CENELEC common modifications (EN)) Clause Requirement + Test Result - Remark Verdict

Contents Add the following annexes:

Annex ZA (normative) Other international publications quoted in this standard with the references of the relevant European publications (See the CB Bulletin)

Annex ZB (nominative) Special national conditions

Annex ZC (informative) A-deviations

P

3.1 Add the following indent at the end of the list

- Exposure to excessive sound pressures from headphones or earphones

NOTE A new method of measurement is described in EN 50332-1, Sound system equipment: Headphones and earphones associated with portable audio equipment – Maximum sound pressure level measurement methodology and limit considerations – Part 1: General method for ”one package equipment”, and in EN 50332-2, Sound system equipment: Headphones and earphones associated with portable audio equipment – Maximum sound pressure level measurement methodology and limit considerations – Part 2: Guidelines to associate sets with headphones coming from different manufacturers.

No sound system. N

4.1.1 Replace the text of the note by: NOTE For ROUTINE TEST reference is made to EN 50333.

Considered. P

5.1.i) Add the following note: NOTE For RATED POWER CONSUMPTION measurements of TVs reference is made to EN 60107.

Not TV apparatus. N

6.1 Replace the entire subclause by: Apparatus including a potential source of ionizing radiation shall be so constructed that personal protection against ionizing radiation is provided under normal operating conditions and under fault conditions.

No ionizing radiation in the equipment

N

Page 42:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

IEC60065(ed.7); am.1 (2005) - Page 2 of 9 -

www.nemko.com Report No. 125414

IEC60065 - ATTACHMENT

Clause Requirement + Test Result - Remark Verdict

Compliance is checked by measurement under the following conditions: In addition to the normal operating conditions, all controls adjustable from the outside BY HAND, by any object such as a tool or a coin, and those internal adjustments or pre-sets which are not locked in a reliable manner, are adjusted so as to give maximum radiation whilst maintaining an intelligible picture for 1 h, at the end of which the measurement is made.

NOTE Soldered joints and paint lockings are examples of adequate locking. The amount of ionizing radiation is regulated by European Council Directive 96/29/Euratom of 13 May 1996. This directive requires that at any point 10 cm from the outer surface of the apparatus, the dose-rate shall not exceed 1µSv/h (0.1 mR/h) taking account of the background level. Moreover, the measurement shall be made under fault conditions causing an increase of the high-voltage, provided an intelligible picture is maintained for 1 h, at the end of which the measurement is made. A picture is considered to be intelligible if the following conditions are met: - a scanning amplitude of at least 70% of the usable screen width; - a minimum luminance of 50 cd/m² with locked blank raster provided by a test generator; - a horizontal resolution corresponding to at least 1.5 MHz in the centre, with a similar vertical degradation; - not more than over flashover per 5 min.

13.3.1 Delete note 4. Deleted. P

14 Delete note 4 and note 5. Deleted. P

15.1.1 Delete notes 1 and 2. Deleted. P

15.2 Delete note 2. Deleted. N

16.1 Delete note 1. Deleted. N

16.2 Delete the note. Deleted. N

20 Delete note 2. Deleted. P

Annex B Replace note 1 by:

In the CENELEC countries listed in IEC 62151, special national conditions apply.

No TNV circuits. N

Annex G Delete the note. Deleted. N

Annex J.2 Delete the notes of Table J.1. Deleted. P

Annex N Add after the introduction: For ROUTINE TEST reference is made to EN

Considered. P

Page 43:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

IEC60065(ed.7); am.1 (2005) - Page 3 of 9 -

www.nemko.com Report No. 125414

IEC60065 - ATTACHMENT

Clause Requirement + Test Result - Remark Verdict

50333.

Bibliography

Add the following standards:

EN 60332-1: 2000, Sound system equipment: Headphones and earphones associated with portable audio equipment – Maximum sound pressure level measurement methodology and limit considerations – Part 1: General method for ”one package equipment”.

PrEN 50332-2 (under consideration), Sound system equipment: Headphones and earphones associated with portable audio equipment – Maximum sound pressure level measurement methodology and limit considerations – Part 2: Guidelines to associate sets with headphones coming from different manufacturers.

Add the following notes for the standards indicated: IEC 60130 NOTE Parts 9 and 17: 1998 are harmonized as Ens (not modified). IEC 60169 NOTE Partly harmonized in the EN 60169/HD 134 series (not modified). IEC 60173 NOTE Harmonized as HD 27 S1: 1978 (not modified). IEC 60335-2-56 NOTE Harmonized as EN 60335-2-56: 1997 (not modified). IEC 60335-2-82 NOTE Harmonized as EN 60335-2-82: 2000 (not modified). IEC 60695 NOTE Harmonized as EN 60695 series (not modified). IEC 61040 NOTE Harmonized as EN 61040: 1992 (not modified). IEC 61558-2-1 NOTE Harmonized as EN 61558-2-1: 1997 (not modified). IEC 61558-2-4 NOTE Harmonized as EN 61558-2-4: 1997 (not modified). IEC 61558-2-6 NOTE Harmonized as EN 61558-2-6: 1997 (not modified).

N

Annex ZA

(normative)

Other international publications quoted in this standard with the references of the relevant European publications This European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies (including amendments). NOTE When an international standard has been modified by common modification, indicated by (mod), the relevant EN/HD applies.

P

Page 44:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

IEC60065(ed.7); am.1 (2005) - Page 4 of 9 -

www.nemko.com Report No. 125414

IEC60065 - ATTACHMENT

Clause Requirement + Test Result - Remark Verdict

Annex ZA

Cont.

P

Page 45:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

IEC60065(ed.7); am.1 (2005) - Page 5 of 9 -

www.nemko.com Report No. 125414

IEC60065 - ATTACHMENT

Clause Requirement + Test Result - Remark Verdict

Annex ZA

Cont.

GROUP DIFFERENCES FOR AMENDMENT 1 COMMON MODIFICATIONS

N

5.1 i) in EN 60065:2002 Replace the note by: NOTE For RATED POWER CONSUMPTION measurements of TVs reference is made to EN 62087. Measurements are done in the ON (play) operating mode.

N

5.4.1

Add the following indent: za) A warning that excessive sound pressure from earphones and headphones can cause hearing loss.

N

6.1 6.1

in EN 60065:2002 Replace the subclause by: Ionizing radiation Equipment that might produce ionizing radiation is checked by measuring the amount of radiation. The amount of radiation is determined by means of a radiation monitor of the ionizing chamber type with an effective area of 1 000 mm2 or by measuring equipment of other types giving equivalent results. Measurements are made with the equipment on test operating at the most unfavourable supply voltage (see 4.2) and with operator controls and service controls adjusted so as to give maximum radiation whilst maintaining the equipment operative for normal use. Internal preset controls not intended to be adjusted during the lifetime of the equipment are not considered to be service controls. At any point 100 mm from the surface of the operator access area, the dose-rate shall not exceed 1 μSv/h (0,1 mR/h) (see Note). Account shall be taken of the background level. NOTE These values appear in Directive 96/29/Euratom.

N

Bibliography in EN 60065:2002

Replace the paragraph related to prEN 50332-2 by: EN 50332-2:2003, Sound system equipment: Headphones and earphones associated with portable audio equipment - Maximum sound pressure level measurement methodology and limit considerations - Part 2: Matching of sets with headphones if either or both are offered

N

Page 46:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

IEC60065(ed.7); am.1 (2005) - Page 6 of 9 -

www.nemko.com Report No. 125414

IEC60065 - ATTACHMENT

Clause Requirement + Test Result - Remark Verdict

separately EN 60065:2002/A1:2006 - 4 -

Bibliography in IEC 60065:2001/A1:2005

Add the following notes for the standards indicated: IEC 60598-2-9 NOTE Harmonized as EN 60598-2-9:1989 + A1:1994 (not modified). IEC 60598-2-17 NOTE Harmonized as EN 60598-2-17:1989 + A2:1991 (not modified).

N

ZB ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN) P

2.6.1 DK: The following is added: Certain types of CLASS I apparatus, see 15.1.1, may be provided with a plug not establishing earthing continuity when inserted in Danish socket-outlets. Justification: Heavy Current Regulations, Section 107.

Class II apparatus. N

13.3.1 NO: To the second paragraph the following is added: In Norway, due to the IT power distribution system used, the a.c. MAINS supply voltage is considered to be equal to the line-to-line voltage, and will remain 230 V in case of a single earth fault. Justification: Based on a use in Norway of an IT power distribution system where the neutral is not provided.

Considered. P

Page 47:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

IEC60065(ed.7); am.1 (2005) - Page 7 of 9 -

www.nemko.com Report No. 125414

IEC60065 - ATTACHMENT

Clause Requirement + Test Result - Remark Verdict

15.1.1 DK: To the first paragraph the following is added: In Denmark, supply cords of single phase appliances having a rated current not exceeding 13 A shall be provided with a plug according to the Heavy Current Regulations Section 107-2-D1. Appliances of CLASS I provided with socket-outlets with earth contact or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with the Heavy Current Regulations Section 107-2-D1 standard sheet DK 2-1a. To the second paragraph the following is added: Socket outlets intended for provided power to CLASS II apparatus with a rated current of 2.5 A shall have the following dimensions:

Dimensions in mm Other dimensions shall be in compliance with the Heavy Current Regulations, Section 107-2-D1, Standard Sheet DKA 1-3 for portable socket-outlets. Shutters are not required. To the third paragraph the following is added: Mains socket-outlets with earthing contact shall be in compliance with the Heavy Current Regulations, Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a. Justification: Heavy Current Regulations, Section 107

Considered. See plug test report.

P

15.1.1 IE: Apparatus which is fitted with a flexible cable or cord shall be provided with a 13 A plug in accordance with Statutory Instrument 525:97, “13 A Plugs and Conversion Adapters for Domestic Use Regulations:1997. Justification: SI 525: 1997

Not applicable. N

Page 48:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

IEC60065(ed.7); am.1 (2005) - Page 8 of 9 -

www.nemko.com Report No. 125414

IEC60065 - ATTACHMENT

Clause Requirement + Test Result - Remark Verdict

15.1.1

Cont.

NO: Mains socket-outlets mounted on CLASS II apparatus shall comply with the specifications given in CEE Publ. 7 as far as a Applicable, with the following amendments: § 8 Dimensions a 2.5 A 250 V two-pole socket-outlets for electronic apparatus shall comply with the enclosed Standard Sheet I.

§ 24 Mechanical strength A 2,5 A 250 V socket-outlets for CLASS II electronic apparatus are tested as specified in 12.1.3 of EN 60065. Also the protecting rim shall be tested Justification: Act of 24 May 1929 relating to supervision of electrical installation (TEA 1929/FEL 1998).

Considered. See plug test report.

P

15.1.1 UK: Apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to BS 1363 by means of that flexible cable or cord and plug shall be fitted with a ”standard plug” in accordance with Statutory Instrument 1768: 1994: The Plugs and Sockets etc. (Safety) Regulations 1994, unless exempted by those Regulations. NOTE ”Standard plug” is defined in SI 1768:1994 and essentially means an approved plug conforming to BS 1363 or an approved conversion plug. Justification: SI 1768: 1994

Not applicable. N

Page 49:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

IEC60065(ed.7); am.1 (2005) - Page 9 of 9 -

www.nemko.com Report No. 125414

IEC60065 - ATTACHMENT

Clause Requirement + Test Result - Remark Verdict J.2 NO: After Table J.1 the following is added:

In Norway, due to the IT power distribution system used, the a.c. MAINS supply voltage is considered to be equal to the line-to-line voltage, and will remain 230 V in case of a single earth fault. Justification: Based on a use in Norway of an IT power distribution system where the neutral is not provided.

Considered. P

ZC ANNEX ZC TO EN 60065, A-DEVIATIONS (EN) N 5.1 IT: Additional markings on the outside of the TV

receiver in Italian language Not TV set. N

IT: User instructions in Italian language including a conformity declaration

Not TV set. N

IT: Certification number on the back cover Not TV set. N 6.1 DE: The following requirement applies:

For the operation of any cathode ray tube intended for the display of visual images operating at an acceleration voltage exceeding 40 kV, authorization is required, or application of type approval (Bauartzulassung) and marking.

Justification: German ministerial decree against ionizing radiation (Röntgenverordnung), in force since 2002-07-01, implementing the European Directive 96/29/EURATOM.

NOTE Contact address: Physikalisch-Technische Bundesanstalt, Bundesallee 100, D-38116 Braunschweig, Tel.: Int+49-531-592-6320, Internet: http://www.ptb.de

No CRT used in the equipment. N

14 SE: Switches containing mercury such as thermostats, relays and level controllers are not allowed. Justification: Ordinance (1990:944) on Prohibition in Connection with handling. Importation and exportation of Chemical Products (Certain Cases)

There are no components containing mercury in the equipment.

N

Page 50:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

IEC 60065 7ed. (2001) - Page 1 of 6 -

www.nemko.com Report No. 125414

ATTACHMENT: AUSTRALIAN / NEW ZEALAND DIFFERENCES to IEC 60065 7th ed. (2001)

Test results according to AS/NZS 60065:2003

Clause Requirement – Test Result - Remark Verdict

ZZ.1 Introduction This Annex sets out variations between this Standard and IEC 60065: 2001. These variations indicate national variations for purposes of the IECEE CB Scheme and will be published in the IECEE CB Bulletin. These variations are indicated within the body of the Standard by shading and strikethrough.

ZZ.2 Variations The variations are as follows:

7.1.5 and Table 3

As an alternative to the method described in footnote f), the following may be used. The ball-pressure test described in AS/NZS 60695.10.2 may be carried out.

Testing is done per footnote f), see main test report.

N

For external parts No external parts. N

For materials supporting parts conductively connected to the mains

N

7.2 As an alternative to the second paragraph, the following may be used. The alternative for the method described in footnote h) of Table 3 may be used.

Testing is done per footnote f), see main test report.

N

15.1.1 After the second paragraph, add the following: Plugs for the connection of apparatus to mains-powered socket-outlets shall comply with AS/NZS 3112 or AS/NZS 3123. Apparatus with a plug portion, suitable for insertion into a 10 A 3-pin flat-pin socket-outlet complying with AS/NZS 3112, shall comply with the requirements of AS/NZS 3112 for equipment with integral pins for insertion into socket-outlets.

Should be considered when marketing in Australian.

15.3.5 In Table 15, in the second and third rows of the first column replace ‘6’ with ‘7.5’.

Should be considered when marketing in Australian.

16.2 In Table 18, in the second and third rows of the first column replace ‘6’ with ‘7.5’.

No power supply cord provided. N

16.3 After item (b) add the following: A flexible cord complying with AS/NZS 3191 need not to undergo this test.

No power supply cord provided. N

20 Add the following after NOTE 2: For alternative test refer to Clause 20.201.

See cl. 20.201 P

20.1.4 In Table 21, in the third and fourth columns change both ‘HB75’ and ‘No requirement’ to ‘V-1’.

Considered. P

Page 51:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

IEC 60065 7ed. (2001) - Page 2 of 6 -

www.nemko.com Report No. 125414 20.2.3 After this Clause, add the following: See below P

20.201 20.201.1

Resistance to fire—Alternative tests General Parts of non-metallic material shall be resistant to ignition and the spread of fire. This requirement does not apply to decorative trims, knobs and other parts unlikely to be ignited or to propagate flames originating from inside the apparatus, or the following: a) Components that are contained in an enclosure having a flammability category of V-0 according to AS/NZS 60695.11.10 and having openings only for the connecting wires filling the openings completely, and for ventilation not exceeding 1 mm in width regardless of length. b) The following parts which would contribute negligible fuel to a fire: - small mechanical parts, the mass of which does not exceed 4 g, such as mounting parts, gears, cams, belts and bearings; - small electrical components, such as capacitors with a volume not exceeding 1 750 mm3, integrated circuits, transistors and optocoupler packages, if these components are mounted on material of flammability category V-1 or better according to AS/NZS 60695.11.10. NOTE – In considering how to minimize propagation of fire and what ‘small parts’ are, account should be taken of the cumulative effect of small parts adjacent to each other for the possible effect of propagating fire from one part to another.

Compliance shall be checked by the tests of 20.201.2.1, 20.201.2.2. and 20.201.2.3 For the base material of PRINTED BOARDS, compliance shall be checked by the test of 20.201.2.4. The tests shall be carried out on parts of non-metallic material which have been removed from the apparatus. When the glow-wire test is carried out, they are placed in the same orientation as they would be in normal use. These tests are not carried out on internal wiring.

The apparatus enclosure is regarded as fire enclosure, made of V-0 and metal. No flammability requirements for the internal components. The PCB is of base material is of flammability category V-1.

N

20.201.2 20.201.2.1

Tests Testing of non-metallic parts Part of non-metallic material shall be subject to the glow-wire test of AS/NZS 60695.2.11 which shall be carried out at 550°C. Parts for which the glow-wire test cannot be carried out, such as those made of soft or

Refer to cl. 20.201.1, not required.

N

Page 52:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

IEC 60065 7ed. (2001) - Page 3 of 6 -

www.nemko.com Report No. 125414

foamy material, shall meet the requirements specified in ISO 9772 for category FH-3 material. The glow-wire test shall not be carried out on parts of material classified at least FH-3 according to ISO 9772 provided that the sample tested was not thicker than the relevant part.

20.201.2.2 Testing of insulated parts Part of insulating material supporting POTENTIAL IGNITION SOURCES shall be subject to the glow-wire test of AS/NZS 64695.2.11 which shall be carried out at 750°C. The test shall be also carried out on other parts of insulating material which are within a distance of 3 mm of the connection. NOTE – Contacts in components such as switch contacts are considered to be connections. For parts which withstand the glow-wire test but produce a flame, other parts above the connection within the envelope of a vertical cylinder having a diameter of 20 mm and a height of 50 mm shall be subjected to the needle-flame test. However, parts shielded by a barrier which meets the needle-flame test need not be tested. The needle-flame test shall be made in accordance with AS/NZS 4695.2.2 with the following modifications:

No such part. N

Clause of AS/NZS 4695.2.2 N

5 Severities Replace with: The duration of application of the test flame shall be 30 s ±1 s.

N

8.2 Test procedure Replace the first sentence with: The specimen shall be arranged so that the flame can be applied to a vertical or horizontal edge as shown in the examples of figure 1.

N

8.4 The first paragraph does not apply. Addition: If possible, the flame shall be applied at least 10 mm from a corner.

N

Page 53:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

IEC 60065 7ed. (2001) - Page 4 of 6 -

www.nemko.com Report No. 125414 8.5

Replace with: The test shall be made on one specimen. If the specimen does not withstand the test, the test may be repeated on two further specimens, both of which shall then withstand the test.

N

10 Evaluation of test results Replace with: The duration of burning (tb) shall not exceed 30 s. However, for printed circuit boards, it shall not exceed 15 s.

N

The needle-flame test shall not be carried out on parts of material classified as V-0 or V-1 according to AS/NZS 60695.11.10 provided that the sample tested was not thicker than the relevant part.

N

20.201.2.3 Testing by needle-flame test If parts, other than enclosures, do not withstand the glow wire tests of 20.201.2.2, by failure to extinguish within 30 s after the removal of the glow-wire tip, the needle-flame test detailed in 20.201.2.2 shall be made on all parts of non-metallic material which are within a distance of 50 mm or which are likely to be impinged upon by flame during the tests of 20.201.2.2. Parts shielded by a separate barrier which meets the needle-flame test shall not be tested. NOTE 1 – If the enclosure does not withstand the glow-wire test the appliance is considered to have failed to meet the requirements of Clause 21.201 without the need for consequential testing. NOTE 2 – If other parts do not withstand the glow-wire test due to ignition of the tissue paper and if this indicates that burning or glowing particles can fall onto an external surface underneath the apparatus, the apparatus is considered to have failed to meet the requirements of Clause 21.201 without the need for consequential testing. NOTE 3 – Parts likely to be impinged upon by the flame are considered to be those within the envelope of a vertical cylinder having a radius of 10 mm and a height equal to the height of the flame, positioned above the point of the material supporting, in contact with, or in close proximity to, connections.

N

20.201.2.4 Testing of printed boards The base material of PRINTED BOARDS shall be

The PCB is of base material is of flammability category V-1.

N

Page 54:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

IEC 60065 7ed. (2001) - Page 5 of 6 -

www.nemko.com Report No. 125414

subject to the needle-flame test of Clause 21.201.2.3. The flame shall be applied to the edge of the board where the heatsink effect is lowest when the board is positioned as in normal use. The flame shall not be applied to an edge consisting of broken perforations, unless the edge is less than 3 mm from a POTENTIAL IGNITION SOURCE. The test is not carried out if the - PRINTED BOARD does not carry any potential ignition source; - base material of PRINTED BOARDS, on which the available power at a connection exceeds 15 VA operating at a voltage exceeding 50 V and equal or less than 400 V (peak) a.c. or d.c. under normal operating conditions, is of flammability category V-1 or better according to AS/NZS 60695.11.10, or the PRINTED BOARDS are protected by an enclosure meeting the flammability category V-0 according to AS/NZS 60695.11.10, or made of metal, having openings only for connecting wires which fill the openings completely; or - base material of PRINTED BOARDS, on which the available power at a connection exceeds 15 VA operating at a voltage exceeding 400 V (peak) a.c. or d.c. under normal operating conditions, and base material of PRINTED BOARDS supporting spark gaps which provides protection against overvoltages, is of flammability category V-0 according to AS/NZS 60695.11.10 or the PRINTED BOARDS are contained in a metal enclosure, having openings only for connecting wires which fill the openings completely. Compliance shall be determined using the smallest thickness of the material. NOTE – Available power is the maximum power which can be drawn from the supplying circuit through a resistive load whose value is chosen to maximize the power for more than 2 min when the circuit supplied is disconnected.

21.201.3 For open circuit voltages greater than 4 kV. POTENTIAL IGNITION SOURCES with open circuit voltages exceeding 4 kV (peak) a.c. or d.c. under normal operating conditions shall be contained in a FIRE ENCLOSURE which shall comply with flammability category V-1 or better according to AS/NZS 60695.11.10.

No voltage exceeds 4 kV. N

Page 55:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

IEC 60065 7ed. (2001) - Page 6 of 6 -

www.nemko.com Report No. 125414 Annex B After the heading add:

For Australia only, this Annex is replaced by the requirements of the Telecommunications Labelling Notice issued under the Telecommunications Act. NOTE – The Telecommunications Act is administered by the Australian Communications Authority.

Apparatus not connected to TNV circuits.

N

Issue Nemko 2007-08

Page 56:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

IEC 60065 7ed. (2001) - Page 1 of 1 -

www.nemko.com Report No. 125414

ATTACHMENT: MALAYSIA DIFFERENCES Test results according to CB BULLETIN No. 112A, December 2006

Clause Requirement - Test Result - Remark VerdictEnergy Commission circular no.1 year 2003 (no.1/2003) States that a Certificate of Approval is required for manufacturing, selling, Advertising, displaying or importing into Malaysia, electrical/electronic products Listed in Annex A

- The supply voltage in Malaysia is 240 Vac, at 50Hz.

Rating voltage is 100-240V P

- Class 0 and 01 appliances are not allowed. Class II apparatus. N

- 13A fused plug-tops shall comply to Malaysian standard (MS 589:Part1:1997), if applicable.

No such parts. N

- 2-pin plug tops shall comply to Malaysian standard (MS 1578:2003) if applicable.

Should be considered when marketing in Malaysia.

Page 57:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 1 of 2 -

PCB layout

www.nemko.com Report No. 125414

Page 58:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 2 of 2 -

PCB layout

www.nemko.com Report No. 125414

Page 59:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 1 of 9 -

Photos

www.nemko.com Report No. 125414

Australia plug

Page 60:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 2 of 9 -

Photos

www.nemko.com Report No. 125414

China plug

Page 61:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 3 of 9 -

Photos

www.nemko.com Report No. 125414

Korea plug

Page 62:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 4 of 9 -

Photos

www.nemko.com Report No. 125414

Taiwan plug

Page 63:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 5 of 9 -

Photos

www.nemko.com Report No. 125414

United Kingdom or Hong Kong plug

Page 64:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 6 of 9 -

Photos

www.nemko.com Report No. 125414

Europe plug

Page 65:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 7 of 9 -

Photos

www.nemko.com Report No. 125414

Fixed Japan plug

Page 66:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 8 of 9 -

Photos

www.nemko.com Report No. 125414

Page 67:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 9 of 9 -

Photos

www.nemko.com Report No. 125414

Page 68:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 1 of 2 -

Transformer specification

www.nemko.com Report No. 125414

Construction / Winding diagram / Component part no: T1

Page 69:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

- Page 2 of 2 -

Transformer specification

www.nemko.com Report No. 125414

Construction / Winding diagram / Component part no: T1

Page 70:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

WWW.NEMKO.COM

Page 1 of 12Order No. 111021P

TEST REPORT IEC 60884-1 / EN 50075 Especially for plug moulded on adaptors

Product Plug for power adapter Standard sheet I

Name and address of the applicant

Eastern Frontier Co., Ltd. 13/F., Chung Mei Centre, Block B, 15 Hing Yip Street, Kwun Tong, Kowloon, Hong Kong

Name and address of the manufacturer

Same as applicant

Name and address of the factories

EASTERN FRONTIER(SHENZHEN)CO.,LTD Factory Bldg #A Hua Fa Road Ind Area Da Lang Village Long Han Shenzhen

Rating and principal characteristics

2.5A 250VAC

Trade mark (If any) Logitech

Model/type EFS01301000130CE

Serial no Test sample without serial number

Additional information

Power adapter for IT equipment.

Tested according to IEC 60884-1: 3rd. Ed. 2002 / EN 50075:90

Part 1: General requirements

Name and address of the testing laboratory

P.O. BOX 73 BLINDERN, N - 0314 OSLO, NORWAY

Telephone (+47) 22 96 03 30 Fax (+47) 22 96 05 50

Test sample(s) received Tested in period

2007-06-20. 2007-06-20 to 2007-07-23. The test results relate only to the sample(s) tested.

Tested by

Signature Date

Jason Chu 2008-07-29 Name in block letters

Verified by

Signature Date

Wilson Wang 2008-07-29 Name in block letters

The content of this TRF fully covers the original TRF published by IMQ, dated 90-07. This form is only for use by NEMKO, or by others according to special agreement with NEMKO. The completed test report is not valid for external use, unless issued by NEMKO or attached to a NEMKO certification document. The report shall not be reproduced without written permission from NEMKO and may then only be copied in full. NEMKO dated 96-01

Page 71:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

WWW.NEMKO.COM

IEC 60884-1 / EN 50075 Especially for plugs moulded on adapters

Page 2 of 12

Order No. 111021P

General remarks:

Description of equipment under test:

Type of accessory: Plug moulded on power adapter Standard sheet: Standard Sheet I (EN 50075)

Copy of marking plate:

Throughout this report a comma is used as the decimal separator. Possible test case verdicts: P = Pass, F = Fail, N = Not applicable. Placed in the column to the right (Verdict) Tested according to additional information: National requirements: Other requirements: Additional information:

1) This test report always as an appended report of test report for direct plug in adapter which is made by Eastern Frontier Co., Ltd. 2) Material used refer to list of critical components for details. 3) This a component type plug (interchangeable) all tests were evaluated when installed to the end product. 4) This test report always as an appended report of IEC 60065:2001 + Amd 1:2005, report no. 111021.

Name and address production-sites (factories):

See page 1

Information about other standards / documents considered:

Tested according to national requirements for the following countries:

Page 72:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

WWW.NEMKO.COM

IEC 60884-1 / EN 50075 Especially for plugs moulded on adapters

Page 3 of 12

Order No. 111021P

General remarks:

List of appendixes / enclosures to the test report:

Page 73:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

WWW.NEMKO.COM

IEC 60884-1 / EN 50075 Especially for plugs moulded on adapters

Page 4 of 12

Order No. 111021P

Clause Requirement - Test Result - Remark Verdict

8 MARKING

8.1 − Rated current 2.5A (0.4A marked on the marking plate of power adapter)

P

− Rated voltage 250V (100-240V~ marked on the marking plate of power adapter)

P

− Symbol for nature of supply ~ P

− Power in Watts (IEC 60884-2-5) Not applicable. N

− Maker's name or trade mark or responsible vendor

Logitech P

− Type reference EFS01301000130CE P

8.4 Marking for plugs shall be easily discernible when the accessory is wired

The required marking is location on the outside surface of the equipment.

P

. Symbol for class II shall not be marked Class II symbol (IEC 60417-1, symbol No. 5072) is applied to the marking plate.

P

8.8 Indelibility of marking water The marking withstands required tests. P

petroleum The marking withstands required tests. P

9 CHECKING OF DIMENSIONS

9.1 Accessories shall comply with relevant Standard Sheet:

Standard sheet I. P

9.3 Deviations from the dimensions specified in the S.S. may be admitted only if they provide a technical advantage

See attachment for result of measurement dimensions.

P

10 PROTECTION AGAINST ELECTRIC SHOCK

10.1 Live parts of plugs shall not be accessible when the plug is in engagement with a socket-outlet

Live parts of plug are not accessed when the plug is in engagement with a socket-outlet.

P

10.2 Accessible parts made of insulating material P

10.4 External parts of plugs or portable socket-outlets shall be made of insulating material

P

12 TERMINALS

12.1.1 Type of terminals: Non-rewirable.

Page 74:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

WWW.NEMKO.COM

IEC 60884-1 / EN 50075 Especially for plugs moulded on adapters

Page 5 of 12

Order No. 111021P

Clause Requirement - Test Result - Remark Verdict12.1.2 Non rewirable accessories provided with

soldered, weldsed, crimped or similar Spring operated connection. P

Screwed or snap-on connection not use Pre-soldered flexible conductors are not used.

P

14 CONSTRUCTION OF PLUG AND PORTABLE SOCKET-OUTLETS

14.2 (24)

Pins shall have adequate mechanical strength (Pins not solid: force 100N for 1min. During the test the dimension of the pin shall not be reduced by more than 0,15mm. After the test the dimension shall not have changed by more than 0,06mm)

Pins are solid. N

14.3 Pins of plugs shall be:

(24.2) − locked against rotation 0.4Nm (sub clause 24.2) P

− locked against rotation, except where rotation is not likely to impair safety or function. (IEC 60884-2-5:95)

N

− not removable without dismantling the plug (Sub-clause 24.10) P

(24.10) − adequately fixed in the body of the plug P

14.6 Pins and socket-contacts shall be resistant to corrosion and abrasion

Pins and socket-contact are resistance to corrosion and abrasion.

P

14.15 The engagement face of plugs shall have no projections other than the pins

P

14.21 Plug classified as class II shall be non-rewirable P

14.23 Plugs which are integral part of other equipment shall not cause overheating or undue strain

P

14.23.1 1,1 x rated voltage of the equipment for 1 h. Temperature rise of the pins shall not exceed 45 K

18 K

P

14.23.2 Additional torque shall not exceed 0,25Nm 0.05Nm P

14.24 The plugs shall be easy to withdraw by hand from the relevant socket-outlet

P

The plugs shall be able to be withdrawn without having to pull on the flexible cable

P

Page 75:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

WWW.NEMKO.COM

IEC 60884-1 / EN 50075 Especially for plugs moulded on adapters

Page 6 of 12

Order No. 111021P

Clause Requirement - Test Result - Remark Verdict

16 RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY

16.1 Resistance to ageing: 70±2°C 168 h

− After 96h: The samples shall show no crack No crack observed. P

− No traces of cloth shall remain on the specimen No traces of cloth remains on the specimen.

P

16.2 Resistance to harmful ingress of water:

− Plugs shall be tested with both fixed and portable socket-outlets if both are defined

IP20 N

16.2.2 Splash-proof IPX4, according to IEC 60529 IP20 N

16.3 Resistance to humidity

ordinary accessories: (X) 48 h

protected accessories: () 168 h

No damage: P

17 INSULATION RESISTANCE AND ELECTRIC STRENGTH

17.1 Insulation resistance measured with 500V DC Results see below,

17.1.2 For plug: a) between all poles connected together and the

body ≥ 5 MΩ

>10MΩ

P

b) between each pole and all others connected to the body ≥ 5 MΩ

>10MΩ P

17.2 Voltage test: 2000V applied for 1 min

(17.1.1 / 17.1.2)

a) No breakdown P

b) No breakdown P

Page 76:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

WWW.NEMKO.COM

IEC 60884-1 / EN 50075 Especially for plugs moulded on adapters

Page 7 of 12

Order No. 111021P

Clause Requirement - Test Result - Remark Verdict

19 TEMPERATURE RISE Not relevant due to minimal circuit current and since 14.23 is fulfilled.

Rated current:

Test current:

The temperature rise of the terminals, after 1h, shall not exceed 45 K:

N

(25.3) The temperature rise of the external parts of insulating material shall be determined

N

24 MECHANICAL STRENGTH

Accessories shall have adequate mech. strength See below,

24.2 Tumbling barrel No. of falls: ( 50 if the specimen does not exceed 50g. 25 if the specimen exceeds 50g. IEC 60884-2-5:95)

25 falls, weight without flexable cable: 120g.

no damage: P

-the pins shall not turn when a torque of 0,4Nm is applied, first in one direction for 1 min. and then in the opposite direction for 1 min.

The pins have not turned after rotation test.

P

24.7 Plug pins provided with insulating sleeves 20 000 movements.

no damage: P

− the insulating sleeve shall not have punctured or rucked up

The insulation sleeve have no punctured or rucked up.

P

24.10 Plug: 70°C for 1 h Pull: 40N for 1 min.

After the test no pin shall have been displaced in the body of the plug more than 1 mm

No displacement. P

25 RESISTANCE TO HEAT

25.1 Heating Cabinet 100°C 1h

No damage, marking shall still be legible:

No damaged and marking still legible. P

25.2 Ball pressure test 125°C impression Φ < 2 mm 0.7mm for plug holder. 1.2mm for enclosure.

P

Page 77:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

WWW.NEMKO.COM

IEC 60884-1 / EN 50075 Especially for plugs moulded on adapters

Page 8 of 12

Order No. 111021P

Clause Requirement - Test Result - Remark Verdict26.3 Pressure contact shall not be transmitted through

insulating material unless there is sufficient resiliency in the metallic parts

P

26.6 Sliding contacts shall be of a metal resistant to corrosion

P

27 CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND

27.1 Creepage distance:

1. Between live parts of different polarity () >4 mm (x) >3 mm

24.2mm (Inside the plug holder)

P

Clearance:

6. Between live parts of different polarity >3 mm 13.5mm (outside the plug holder) P

28 RESISTANCE OF INSULATING MATERIAL TO ABNORMAL HEAT, FIRE AND TRACKING

28.1 Resistance to abnormal heat and to fire

28.1.1 Glow-wire test (X)750°C for parts retaining necessary current carrying parts. ( )650°C must be tested in the end product.

There shall be no visible flame and no sustained glowing, or the flame shall extinguish within 30s There shall be no ignition of the tissue paper

No visible flame, no sustained glowing and no ignition of the tissue paper.

P

28.1.2 Pins with insulating sleeves: T 120°C for 3h impact test.

100g 100mm 4 impacts No cracks No cracks. P

28.2 Accessories other than ordinary shall be of material resistant to tracking

IP20 N

A flat surface is to be tested:

V = 175 V 50 drops N

No flash-over or breakdown shall occur N

30 ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES

30.1 Pressure test at high temperature

Force: 2,5N T 200°C for 2h The thickness of the insulation is measured at the point of impression

0.90mm (original) 0.86mm (at the point of impression)

Page 78:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

WWW.NEMKO.COM

IEC 60884-1 / EN 50075 Especially for plugs moulded on adapters

Page 9 of 12

Order No. 111021P

Clause Requirement - Test Result - Remark Verdict The thickness within the area of the impression

shall be not less than 50% of the thickness measured before the test

95.5% (The thickness is not less than 50% of the thickness before the test).

P

30.2 Static damp heat test (IEC 68-2-30) After the treatment the specimens are submitted to the following tests:

− insulation resistance and electric strength, in accordance with clause 17

P

− abrasion test, in accordance with clause 24.7 P

30.3 Test at low temperature: -15°C for 24h

After recovering to ambient temperature, the specimens are submitted to the following tests:

− insulation resistance and electric strength, in accordance with clause 17

No breakdown. P

− abrasion test, in accordance with clause 24.7 The insulation sleeve have no punctured or rucked up.

P

30.4 Impact test at low temperature: -15°C for 24h

The specimens are submitted to an impact test: 100g 100mm 4 impacts

No cracks shall be visible No visible cracks. P NOTE:

Page 79:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

WWW.NEMKO.COM

IEC 60884-1 / EN 50075 Especially for plugs moulded on adapters

Appendix

Supplementary tests according to EN 50075 (1990)

Page 10 of 12

Order No. 111021P

Clause Requirement - Test Result – Remark Verdict6 MARKING

6.1 − Rated current 2.5A (0.4A marked on the marking plate of power adapter)

P

− Rated voltage 250V (100-240V~ marked on the marking plate of power adapter)

P

− Nature of supply ~ P

− Maker's name or trade mark or responsible vendor

Logitech P

− Type reference EFS01301000130CE P

6.4 Marking shall be indelible and easily legible

- 15s water The marking withstands required tests.

P

- 15s hexane The marking withstands required tests. P

9 CONSTRUCTION 9.5 Effective permanent connections: Soldered. P

Screwed or snap-on connections shall not be used. According to IEC 60884-2-5 screwed or snap-on connection is allowed

No screwed or snap-on connections used.

P

9.6 Gripping operation: length ≥ 55mm or Operated only with accessories. N

indent(s) - ball φ 12mm N

13 MECHANICAL STRENGHT 13.4 Pull test with steel plate: 40N for 1 min. in heating

cabinet 70 oC Displacement ≤ 1 mm No displacement. P

14 RESISTANCE TO HEAT AND AGEING 14.2 Ageing test : 70±2°C 168 h

After the test: no visible crack P no sticky or greasy material P no damage P

Page 80:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

WWW.NEMKO.COM

IEC 60884-1 / EN 50075 Especially for plugs moulded on adapters

Appendix

Supplementary tests according to EN 50075 (1990)

Page 11 of 12

Order No. 111021P

Clause Requirement - Test Result – Remark Verdict15 CURRENT-CARRYING PARTS AND

CONNECTIONS

15.1 Connections shall withstand the mechanical stresses occuring in normal use

P

15.2 Contact pressure shall not be transmitted through insulating material

P

15.3 Current-carrying parts shall be: copper or N alloy 58% or 60-61.2 % (according to declaration

from manufacturer) P

alloy 50% or N other metal no less suitable N Current-carrying parts which may be subjected to

mechanical wear, shall not be made of steel provided with an electroplated coating

P

16 CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND

Creepage distance between: − live parts of different polarity 3 mm 24.2mm (Inside the plug holder) P

− live parts and accessible metal parts 3 mm N

Clearances between: − live parts of different polarity 3 mm 13.5mm (outside the plug holder) P

− live parts and accessible metal 3 mm

N

For moulded-on: distance through insulating material ,between

− live parts and accessible surfaces 1,5 mm N

17 RESISTANCE OF INSULATING MATERIAL TO ABNORMAL HEAT AND FIRE

Glow-wire test: for parts of insulating material necessary to retain

current-carrying parts in position (x)750°C

for other parts ( )650°C must be tested in the end product.

− no visible flame P

Page 81:  · 2. The unit provide with Korea plug, China plug, Europe plug, United Kingdom plug, Hong Kong plug, Australia plug, fixed Japan plug and Taiwan plug. Only the Europe plug has been

WWW.NEMKO.COM

IEC 60884-1 / EN 50075 Especially for plugs moulded on adapters

Appendix

Supplementary tests according to EN 50075 (1990)

Page 12 of 12

Order No. 111021P

− no sustained glowing and the flame shall

extinguish within 30s P

− no ignition of the tissue paper P

NOTES:

Appended TABLE: list of critical components P

object/part No. manufacturer/ trademark

type/model technical data standard mark(s) of conformity1)

Enclosure Sabic Innovative Plastics China Co., Ltd.

940(f1) V-0 min., min. 120°C min. 1.5 mm thick

UL94 UL

Plug Body Sabic Innovative Plastics China Co., Ltd.

SE1X (GG)(f1) V-1, min. 1.5mm thick

UL94 UL

Pins Various Metal, 60-61.2% copper

Test in the equip.

Measurement of Dimensions

Item Limit measured Item Limit measured A 25.6mm to 26.6mm 26.1mm G Ф = 0.7mm to 1.7mm N/A B 13.0mm to 14.4mm 13.6mm H 4mm min. 18.2mm

C1 18mm to 19.2mm 18.4mm I 10mm to 11mm 10.3mm C2 17mm to 18mm 17.1mm J 18.5mm to 19.5mm 19.1mm D 34.6mm to 36.0mm 35.1mm K Ф=3.94mm to 4.06mm 4.0mm E R=5mm to 6mm 5.5mm L Ф=3.8mm max. 3.6mm F 2mm max. N/A