2002. emergency relief items catalogue 2002

143
Water and Sanitation Water and sanitation 317 Pump enquiry questionnaire 319 Kit, motor pump, raw water, diesel engine, 2” 321 Kit, motor pump, raw water, diesel engine, 3” 323 Kit, motor pump, raw water, petrol engine, 2" 325 Hand pump, raw water, Afridev 327 Hand pump, raw water, Indian Mk.III 329 Hand pump, raw water, Kardia K50 and K65 331 Kit, pump, submersible, borehole testing, + generator 333 Kit, pump, submersible, for borehole, + generator 335 Kit, pump, submersible, dewatering, 2", low voltage 110V 337 Kit, pump, electrical, drainage, 2", 15m3/h at 15m 339 Kit, motor pump, sludge, diaphragm, diesel, 4”, 25m3/h at 10m 341 Kit, motor pump, sludge, diaphragm, diesel, 3”, 15m3/h at 10m 343 Kit, pump, submersible, sewage, max. 40 m3/h, max.20m + generator 6KVA 345 Flexible water tanks, onion type 347 Flexible water tanks, bladder type 349 Flexible tank for water transport, 5m 3 , bladder type 351 Repair kit, for flexible water tank 353 Rigid water tank, corrugated steel sheets + liner 355 Kit, fittings, 3", for 3 rigid corrugated water tanks 359 Kit, tool, for rigid watertanks 361 Kit, adaptors, fittings for other systems, tanker truck 362 Coupling “Storz” 363 Galvanised couplings 364 Couplings, compression 365 Strainers 366 Band clips 367 Sealing, for water couplings 368 Hose, spiralled 369 Hose, flat 370 Pipe, PVC 371 Valves 372 Water distribution kit 373 Tap stand, water collection point 374 Diatomite earth 376

Upload: ngohuong

Post on 16-Jan-2017

273 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: 2002. Emergency Relief Items Catalogue 2002

Water and Sanitation Water and sanitation 317 Pump enquiry questionnaire 319 Kit, motor pump, raw water, diesel engine, 2” 321 Kit, motor pump, raw water, diesel engine, 3” 323 Kit, motor pump, raw water, petrol engine, 2" 325 Hand pump, raw water, Afridev 327 Hand pump, raw water, Indian Mk.III 329 Hand pump, raw water, Kardia K50 and K65 331 Kit, pump, submersible, borehole testing, + generator 333 Kit, pump, submersible, for borehole, + generator 335 Kit, pump, submersible, dewatering, 2", low voltage 110V 337 Kit, pump, electrical, drainage, 2", 15m3/h at 15m 339 Kit, motor pump, sludge, diaphragm, diesel, 4”, 25m3/h at 10m 341 Kit, motor pump, sludge, diaphragm, diesel, 3”, 15m3/h at 10m 343 Kit, pump, submersible, sewage, max. 40 m3/h, max.20m + generator 6KVA 345 Flexible water tanks, onion type 347 Flexible water tanks, bladder type 349 Flexible tank for water transport, 5m3, bladder type 351 Repair kit, for flexible water tank 353 Rigid water tank, corrugated steel sheets + liner 355 Kit, fittings, 3", for 3 rigid corrugated water tanks 359 Kit, tool, for rigid watertanks 361 Kit, adaptors, fittings for other systems, tanker truck 362 Coupling “Storz” 363 Galvanised couplings 364 Couplings, compression 365 Strainers 366 Band clips 367 Sealing, for water couplings 368 Hose, spiralled 369 Hose, flat 370 Pipe, PVC 371 Valves 372 Water distribution kit 373 Tap stand, water collection point 374 Diatomite earth 376

Page 2: 2002. Emergency Relief Items Catalogue 2002

Aluminium sulfate 377

Water purification agent 378 Chlorine, NaDCC 379 Chlorine, HTH 382 Water purification unit, GBI 3000 385 Water purifier unit, 5.4m3 at 75NTU, transportable 387 Water purifier unit, 3m3/hour at 20NTU, transportable 389 Floating container for slow dissolving chlorine 390 Kit, water treatment, suction side doser 391 Kit, water treatment, Sanikit 393 Kit, treatment unit, filter tank kit 395 Kit, water testing, portable microbiological laboratory 397 Water testing, Aluminium 398 Turbidity measuring tube, 5 to 2000NTU, plastic 399 Pool testor 400 Sanplat, squatting plate moulding set 401 Squatting plate, polypropylene, + drop-hole cover 402 Sprayer 403 Fly catcher 404 Body bag 405 Lime, quick lime / slacked lime 406 Insecticides 407 Measuring instruments, for water and sanitation 409 Tripod, for well 410 Emergency Response Unit, Water and Sanitation 411 Emergency Response Unit WatSan - Water treatment and supply module 413 Emergency Response Unit WatSan - Water distribution and trucking module 425 Emergency Response Unit WatSan - Specialised Wat-San module 433 Emergency Response Unit WatSan - Mass Sanitation module 439 Typical generator fault finding procedure 441 Technical data for pumping and generating sets 447 Installation of pumps and generating sets 451 Electrical technical data 463

Page 3: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 317

Water and sanitation

Introduction This chapter of the catalogue is a reference document for Water & Sanitation technical staff in the field as well as for headquarters staff of National Red Cross/Red Crescent Societies. It is also meant as a standardization tool and guideline for those who are responsible for the procurement of Water & Sanitation equipment. The Federation and the ICRC made the original January 2001 Edition of the 'WatSan Emergency Equipment Catalogue' with the extensive support of Pumping Systems Ltd (PSL), Pumpsets Ltd, and Butyl Ltd. The following pages are based on that First Edition.

Standard WatSan Kits For many years the Red Cross Red Crescent Movement and other agencies involved in relief, medical aid and development works around the world have been acutely aware of the health hazards created by inadequate water supplies. Although improvements in sanitation, health care, food supplies, and housing are important, the overall well being of refugees or any other group of people, relies heavily on the adequacy and quality of the water supply. Where time and expertise are available for long term programs, the most appropriate and cost effective water supply schemes can be worked out, each one related to the nature of the particular water source and the availability of expertise, equipment and materials. But where urgent and often difficult emergency conditions prevail, there is a need for simpler and quicker solutions. The kits and sets have been devised to help provide a reliable water supply, primarily for emergency conditions such as refugee camps and disaster relief operations. At present there are over 40 packs covering a wide range of possible requirements, each designed to serve a particular purpose in providing water and sanitation. Many of these kits are included in the Water and Sanitation Emergency Response Unit, available from a number of National Societies. The equipment is designed to be readily available, easily transported, rapidly assembled, simple to use and maintain, and to provide an adequate safe water supply at best possible cost. Each pack or kit is completely self-contained with all the necessary items including spare parts, tools, and instructions. The Packs are designed with the following general characteristics: - Number of people catered for: 5000 from each Pack.

- Planned consumption per day: 15 liters per person.

- Provide drinking water of a suitable quality for general purpose.

- Installation by a team of semi skilled workers, with some oversight from an experienced engineer.

- Designed for above or below ground installation depending on the soil conditions and/or site topography.

- Operated by gravity distribution when conditions on site allow.

More detailed information about Minimum Standards in Disaster Response are available from the Sphere Project. www.sphereproject.org

Page 4: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

318 Water and Sanitation

Equipment stocks For many locations the possibility to stock equipment for use in emergencies is either a priority or would be one if available facilities existed. Stocks exist in different locations of the world where the most frequently used items, kits, and Emergency Response Unit packages are ready to ship in a standard format from a number of National Societies of the Red Crescent and the Red Cross. If it is felt desirable to put in place a local stock then assistance is always available in HQ. It is suggested that a small stock should consist of equipment that is multi-purpose in character. An example would be : - Motorpumps, General Purpose/Solids Handling (Petrol or Diesel)

- 5000 l Truck Bladder Tank Kit

- Tap Stands

Compatibility with other systems The Adaptor Kit (KWATFITT02) enables the interconnection to water systems of other agencies who may not use the ‘Storz’ coupling system which is the Red Cross standard.

Budget pricing The data sheets include an indicative budget price (FCA supplier warehouse) to serve as a first estimate. The weight and volume information associated with freight rates will complete the budget estimate.

Page 5: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 319

PUMP ENQUIRY QUESTIONNAIRE In case of doubt about specifying the correct type of pump, this questionnaire will give all necessary information to your technical support to help choose the right equipment. Complete it and CIRCLE or X descriptions that are relevant. If possible provide a sketch of the intended layout showing relative levels or altitudes.

Conditions of Service Project -Site .................................-Country........................................ Max.Ambient Site Temperature .........°C /°F Service -Fixed /Mobile /Dewatering /..................... New /Replacement *Source -Borehole /Well /River /Lake /Spring /............ Liquid -Potable/Raw Water /........................ Self priming ...........Yes /No Solids Content ...............Yes /No Size of Solids -fine mud /sandy /rocks -Max.Solids Size ................cms /inches Raw Sewage /Sludge ........Yes /No Capacity/Volume flow Rate -.................m3/hr or ............- Continuous /Intermittent /.........Hours/Day Total Dynamic Head (TDH)-............Metres /feet /psig -Suction Lift ............Metres /Feet -Altitude above Mean Sea Level ..........m /Ft. or System Layout -Vertical Height from water source to delivery highest point ...............................................metres /Ft. -Length,type &diameter of delivery pipeline(s).............................................................metres /Ft. *If Replacement note Pump Description

Pump Description &Accessories Number of Units -......... Baseplate -Fixed /Skid /Trolley or High Speed Trailer Mounted -Single Lift Point ..........Yes /No Suction /Delivery Lines -Length .........../...........m /Ft.Diameter .........../..........mm /in. Connections -Screwed /Flanged (Table .....................Rating)Quick Coupling -Yes /No (NB.STORZ quick couplings preferred)

Drive Type -Motor /Electric /Hydraulic /Air Electric Power Supply ..........v/....ph/.....Hz Make (preferences according to standard in use)-............................... -or Engine /Diesel /Petrol /Solar /Steam /Human /.................................... Cooling -Air /Radiator /Heat Exchanger Enclosure -Indoor /Outdoor /Canopy Open /Weatherproof /Silenced <..................dBA Starter Type -for Electric Motor ..DOL /Star Delta /Soft /Variable Speed /Manual /Auto /.................... -for Diesel Engine ..Hand /Electric /Air /Spring /.................Variable Speed (NB.Manual /Spring preferred)

Page 6: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 321

Kit, motor pump, raw water, diesel engine, 2”

Code Description Ind. price Ship. weight Ship. Vol. KWATPUMCRW02 KIT,MOTOR PUMP, raw water, diesel,

2”, 24m3/h at 20m CHF 2400 195kg 1.17x0.78x0.96m

Total vol.0.88m³ Cold chain: No Dangerous: No Regulated: No

General information Self-Priming Diesel Pump 2 inch /5 kW with Lombardini 15LD350 engine

- Specify the type of engine on your order if different from the Lombardini type (see alternative in the specifications). It is recommended to maintain maximum standardisation in one location/region with the same brand and type of engine.

This kit includes all necessary items to run the pump and all the connectors to fit with 2” or 3” pipework through Storz or thread couplings. The engine oil included allows starting plus one oil change. The spare parts set is meant for 2000hours (estimated life of the machine in hard condition).

This pump accepts raw water with limited amount of very small solids. It can be used for raw water, clear water or chlorinated water. It can exceptionally be used for drainage. It cannot be used for sewage and sludge pumping.

Specifications Standard engine: Lombardini 15LD350 (Diesel)/5 kW at 3600 rpm

- Alternative engines: Lister AC1 (Diesel)/4.5kW at 3000 rpm

Hatz 1B30-1 (Diesel)/4.5 kW at 3600 rpm

- Diesel 4 stroke. Single cylinder. Direct injection. Not turbo charged. Air-cooled. Variable speed control. Recoil manual start. Dry air filter. Exhaust silencer. Oil and fuel filters. Low oil level security cut off. Fuel tank: 4lt (= 5 hours running time).

Centrifugal self-priming pump in cast iron construction. Integral non-return valve. Renewable rubber coated wear plate. Cast iron high efficiency clog resistant impeller. Max solids handling 14mm. Carbon/ceramic faced mechanical seal. Detachable discharge bend.

Engine close coupled with pump. Mounted on fabricated steel base with 2 wheeled site trolley.

Packaging: 1wooden box 1.17 x 0.78 x 0.96m, with ISO pallet base.

Page 7: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

322 Water and Sanitation

- One side of the packaging box is designed as a detachable ramp for loading/offloading the pump. Inside the box a divider protects components. Box lined inside with a tar coated paper to protect from water.

Kit content list Code Description Qty WPUCESDR001 PUMP, END-SUCTION, diesel, Self-Priming, 2"/4.5kW 1

WNECGANN2M2M COUPLING, GALVA, NIPPLE, 2", threaded male/male 2

WNECGABB2F2F COUPLING, GALVA, BEND, 2", 90°, thr fem/fem, large radius 1

WNEVBRGA2FF VALVE, GATE, brass, 2", thread fem/fem 1

WNEASTNR3 STRAINER + check valve, 3", thread fem. 1

WNECBRCA3M3T COUPLING, BRASS, ADAPTOR, thread male 3" to hose tail 3" 1

WNECBRCA2M2T COUPLING, BRASS, ADAPTOR, thread male 2" to hose tail 2" 1

WNECGACR3M2F COUPLING, GALVA, REDU, 3"-2", thread male/fem. 1

WNEABACL50-70 BAND CLIP, high pressure, 50-70mm 2

WNEABACL77-95 BAND CLIP, high pressure, 77-95mm 2

WNECSTCC2SM COUPLING, half symetrical 'Storz', 2", threaded male 2

WNECSTCR3-2 COUPLING, half symetrical 'Storz', 3"-2", reduction 2

WNECSTHO2-3 (coupling half sym. Storz) HOOK SPANNER, 2"-3" 1

TVECLUBRO26 OIL, ENGINE, diesel/petrol, 15W40, 5lt plastic container 1

TVECMVACBT20 FUNNEL, diam. 200 mm, bent spout + mesh filter 1

TVECJCANM20 JERRYCAN, 20 l, metallic 1

APACWBOX1108 BOX, 20mm plywood, 1.1x0.7x0.8m, pallet base + ramp 1

WSPPLOMB6339 MECHANICAL SEAL, Quiete/Paio pumps, ref:6339+6353 1

WSPPLOMB6101 VALVE, rubber, Quiete pump, ref:6101 1

WSPPLOMB3647 FUEL FILTER, element, Lombardini 15LD/3LD, ref SK3647 3

WSPPLOMB5155 OIL FILTER, element, Lombardini 15LD350, ref SO5155 3

WSPPLOMB1961 AIR FILTER, element, Lombardini 15LD350, ref SL1961 3 WSPPLOMBGUQU USER + SPARE PART GUIDE, Lombardini Quiete 1 Or ALTERNATIVE ENGINE SPARE PARTS KIT

Page 8: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 323

Kit, motor pump, raw water, diesel engine, 3”

Code Description Ind. price Ship. weight Ship. Vol. KWATPUMCRW03 KIT, MOTOR PUMP, raw water, diesel,

3", 48m3/h at 25m CHF 3‘900 207kg 1.17x0.78x0.96m

Total vol.0.88m³ Cold chain: No Dangerous: No Regulated: No

General information Self-Priming Diesel Pump 3 inch / 6.7kW with LOMBARDINI 3LD510 engine

- Specify the type of engine on your order if different from the Lombardini type.

- The alternative types may present different characteristics with the standard type.

This pump accepts raw water with limited amount of very small solids.

Spare part set suitable for starting operation.

Specifications Standard engine: Lombardini 3LD510 (Diesel)/6.7kW at 3000 rpm

- Alternative engines: Lister LV1(Diesel)/6.7kW at 3000 rpm

Hatz 1D50-1(Diesel)/ 6.6kW at 3600 rpm

- Diesel 4 strokes. Single cylinder. Direct injection. Not turbo charged. Air-cooled. Variable speed control. Recoil manual start. Dry air filter. Exhaust silencer. Oil and fuel filters. Low oil level security cut off. Fuel tank: 4L minimum.

Centrifugal self-priming pump in cast iron construction. Integral non-return valve. Renewable rubber coated wear plate. Cast iron high efficiency clog resistant impeller. Max solids handling 19mm. Carbon/ceramic faced mechanical seal. Detachable discharge bend and screwed BSP suction/discharge connections.

Engine close coupled with pump. Mounted on fabricated steel base with 2 wheeled site trolley.

One side of the packaging box is designed as a detachable ramp for loading/offloading the pump. Inside the box a divider protects components. Box lined inside with a tar coated paper to protect from water.

Page 9: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

324 Water and Sanitation

Kit content list Code Description Qty WPUCESDR002 PUMP, END-SUCTION, diesel, Self-Priming, 3"/6.1kW 1

WNECGANN3M3M COUPLING, GALVA, NIPPLE, 3", threaded male/male 2

WNECGABB3F3F COUPLING, GALVA, BEND, 3", 90°, thr fem/fem, large radius 1

WNEVBRGA3FF VALVE, GATE, brass, 3", thread fem/fem 1

WNEASTNR3 STRAINER + check valve, 3", thread fem. 1

WNECBRCA3M3T COUPLING, BRASS, ADAPTOR, thread male 3" to hose tail 3" 1

WNEABACL77-95 BAND CLIP, high pressure, 77-95mm 2

WNECSTCC3SM COUPLING, half symetrical 'Storz', 3", threaded male 2

WNECSTHO2-3 (coupling half sym. Storz) HOOK SPANNER, 2"-3" 1

TVECLUBRO26 OIL, ENGINE, diesel/petrol, 15W40, 5lt plastic container 1

TVECMVACBT20 FUNNEL, diam. 200 mm, bent spout + mesh filter 1

TVECJCANM20 JERRYCAN, 20 l, metallic 1

APACWBOX1108 BOX, 20mm plywood, 1.1x0.7x0.8m, pallet base + ramp 1

WSPPLOMB6339 MECHANICAL SEAL, Quiete/Paio pumps, ref:6339+6353 1

WSPPLOMB6103 VALVE, rubber, Paio pump, ref:6103 1

WSPPLOMB3647 FUEL FILTER, element, Lombardini 15LD/3LD, ref SK3647 3

WSPPLOMB4701 OIL FILTER, Lombardini 3LD510, ref FT4701 3 WSPPLOMBGUPA USER + SPARE PART GUIDE, Lombardini Paio 1 Or ALTERNATIVE ENGINE SPARE PARTS KIT

Page 10: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 325

Kit, motor pump, raw water, petrol engine, 2"

Code Description Ind. price Ship. weight Ship. Vol. KWATPUMCRW01 KIT, MOTOR PUMP, raw water, petrol,

2", 18m3/h at 15m CHF 1’000 1 parcel

36kg 0.49x0.4x0.36m Total vol.0.25m³

Cold chain: No Dangerous: No Regulated: No

General information Petrol engine motor pump for moderate duty:

- Honda WH20X, typical flow: 24m³/20m (standard in ICRC kit)

- Briggs and Stratton Vanguard C50, typical flow: 20m³/20m (alternative option)

- Briggs and Stratton C50, flow: 15m³/18m (standard in Federation ERU trucking module)

Standard side valve engine is the cheapest solution. OHV engine to be specified for fuel economy and/or environmental compliance (lower emissions).

Can run approximately 8 hours discontinuous per 24 hours in normal condition or a minimum of 5 hours continuous operation with a refueling stop in ambient temperatures up to 40°C. Expected life span of 500 to 1000 hours.

Spare part set suitable for starting operation.

Specifications Standard engine: Briggs and Stratton 127432 + (Petrol)/ 2.6kW at 3600 rpm

- Alternative engines: Honda GX160 (Petrol)/ 4kW at 36000 rpm

Briggs and Stratton Vanguard 91202 (Petrol)/ 4kW at 3600 rpm

- Petrol 4 strokes. Single cylinder 150cc. B&S side valves, Honda OHV. Horizontal butterfly carburator. Not turbo charged. Air-cooled. Variable speed control. Recoil manual start. Dry air filter. Exhaust silencer. Oil and fuel filters. Low oil level security cut off. Fuel tank: 3lt (= 2 to 3 hours running time).

Centrifugal self-priming pump. Cast iron high efficiency clog resistant impeller. Max solids handling 6mm. Carbon/ceramic faced mechanical seal. Detachable discharge bend and screwed NPT suction/discharge connections.

Engine close coupled with pump. Mounted inside powder coated steel roll frame on anti-vibration mounts.

Page 11: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

326 Water and Sanitation

Kit content list Code Description Qty WPUCESRW002 PUMP, END-SUCTION, petrol, Self-Priming, 2"/2.6kW 1

WNECGANN2M2M COUPLING, GALVA, NIPPLE, 2", threaded male/male 2

WNECGAEE2F2F COUPLING, GALVA, BEND, 2", 90°, thr fem/fem, large radius 1

WNEVBRGA2FF VALVE, GATE, brass, 2", thread fem/fem 1

WNEASTNR3 STRAINER + check valve, 3", thread fem. 1

WNECBRCA3M3T COUPLING, BRASS, ADAPTOR, thread male 3" to hose tail 3" 1

WNECBRCA2M2T COUPLING, BRASS, ADAPTOR, thread male 2" to hose tail 2" 1

WNECGACR3M2F COUPLING, GALVA, REDU, 3"-2", thread male/fem. 1

WNEABACL50-70 BAND CLIP, high pressure, 50-70mm 2

WNEABACL77-95 BAND CLIP, high pressure, 77-95mm 2

WNECSTCC2SM COUPLING, half symetrical 'Storz', 2", threaded male 2

WNECSTCR3-2 COUPLING, half symetrical 'Storz', 3"-2", reduction 2

WNECSTHO2-3 (coupling half sym. Storz) HOOK SPANNER, 2"-3" 1

TVECLUBRO26 OIL, ENGINE, diesel/petrol, 15W40, 5lt plastic container 1

TVECMVACBT20 FUNNEL, diam. 200 mm, bended spout + metallic filter 1

TVECJCANM20 JERRYCAN, 20 l, metallic 1

APACWBOX1108 BOX, 20mm plywood, 1.1x0.7x0.8m, pallet base + ramp 1

FUEL FILTER, Honda 1

OIL FILTER, Honda 1

AIR FILTER, Honda 1

OPEN SPANNER, Honda 10mm 1

SCREWDRIVER, Honda mm 1

OPEN SPANNER, Honda 12mm 1

SPARK PLUG SPANNER, Honda 17mm 1 USER + SPARE PART GUIDES, Honda 1 Or ALTERNATIVE ENGINE SPARE PART KIT

Page 12: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 327

Hand pump, raw water, Afridev

Code Description Ind. price Ship. weight Ship. Vol. WPUHSURWAFR1 HAND PUMP, submersible, raw water,

Afridev, 4" 5 units = 3parcels

300+270+150 Total 720kg

5 units = 3 parcels 1.18x0.96x1.1m 1.38x0.79x0.54m 3.25x0.25x0.24m

Total vol.2.03m³ Cold chain: No Dangerous: No Regulated: No

General information Lever Operated Lift Pump for up to 45 metres setting in a borehole of 4” diameter with a 63mm

cylinder.

Minimum borehole diameter 100mm. Maximum borehole diameter 150mm. Some manufacturers quote a minimum borehole ID of 110mm

Meets V.L.O.M requirements (village level operated maintenance).

Pump performance with 63mm cylinder (basis 50 full strokes /minute):

- Setting at 30m: Capacity 0.4125 litres/stroke Output 1240 litres/hour

Manual installation possible, special lifting gear may be needed over 30m

PVC riser may have to be locally sourced (Shipping information excludes riser), complete kit list includes riser.

Stainless Steel pump rods recommended for water of pH>6.5 or iron content>1 ppm

Specifications Pump Cylinder Assembly -extruded brass liner inside uPVC pipe jacket Plunger fitted Nitrile rubber ‘U ’ seal Injection molded suction and discharge valves Large diameter suction tube reduces sand intake into cylinder Drive Head Galvanized fabricated mild steel head Adjustable handle /lever length to suit different installation depths Open top cylinder design allows extraction of plunger & footvalve in situ Replaceable plastic bush bearings (4 per unit) Pump head cover to exclude well pollution Separate assemblies of pump cylinder and drive head

Page 13: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

328 Water and Sanitation

Kit content list HAND PUMP, submersible, raw water, Afridev, 4" 63mm Ø x 4.7mm wall uPVC rising main in 2.9m sections with centralisers 10mm Ø x 3 m galvanised mild steel pump rods with forged hook and eye connectors with rubber rod centralisers Installation &Maintenance Tool Kit including Fishing tool, Nylon rope, Solvent Cement, Open ended & Socket spanners 1 years spare parts kit inc.centralisers, bush bearings, valve bobbins &seals General complete set of operator manuals in English Red Cross /Crescent logo painted in red on white background

Options - Accessories Concrete Pedestal version Stainless Steel pump rods

Page 14: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 329

Hand pump, raw water, Indian Mk.III

Code Description Ind. price Ship. weight Ship. Vol. WPUHSURWMK31 HAND PUMP, submersible, raw water,

India MkIII, 4", maxi. 60m 5 units = 3 parcels

300+270+650 Total 1220kg

5 units = 3 parcels 1.18x0.96x1.1m 1.38x0.79x0.54m 3.25x0.45x0.54m Total vol. 2.63m³

Cold chain: No Dangerous: No Regulated: No

General information Lever Operated Lift Pump for up to 60 metres setting in a borehole of 4” to 6” diameter with a

50mm cylinder.

Meets V.L.O.M requirements (village level operated maintenance).

Larger pump cylinder 63.5mm Ø ID for higher capacity at shallower settings. Optional cylinder requires 65mm rising main

Large diameter suction tube reduces sand intake into cylinder

Pump performance (basis 50 full strokes /minute):

- 50mm cylinder setting at 45m: Capacity 0.222 litres/stroke Output 800 litres/hour

- 63.5mm cylinder setting at 30m: Capacity 0.375 litres/stroke Output 1125 litres/hour

Manual installation possible -special lifting gear may be needed over 30m

Stainless Steel pump rods/riser for water of pH>6.5 or iron content>1 ppm

Specifications Pump Cylinder Assembly -brass liner inside cast iron body &end caps Gunmetal Plunger fitted Nitrile rubber cup washer Injection molded suction and discharge valves Drive Head galvanized fabricated mild steel head with chain &quadrant mechanism Long &heavy handle bar to counter balance the connecting rod weight Open top cylinder design allows extraction of plunger &check valve in situ Replaceable plastic bush bearings (4 per unit) Pump head cover to exclude well pollution Separate assemblies of pump cylinder and drive head

Page 15: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

330 Water and Sanitation

Kit content list HAND PUMP, submersible, raw water, India MkIII, 4", maxi. 60m 50mm Ø galvanized mild steel rising main in 3-m sections 12mm Ø x 3m galvanized mild steel pump rods with threaded couplers Stroke length 125mm Installation &Maintenance Tool Kit including special tools &spacers 1-year spare parts kit inc. shielded bearing, chain assembly, valves with rubber seating, pump cup/bucket washers &seals General set of operator manuals in English Red Cross /Crescent logo painted in red on white background

Options - Accessories Pump cylinder 63.5mm Ø ID Stainless steel pump, rods, risers

Page 16: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 331

Hand pump, raw water, Kardia K50 and K65

Code Description Ind. price Ship. weight Ship. Vol. WPUHSURWKAR1 HAND PUMP, submersible, raw water,

Kardia K50VA, 4" CHF 1’800

CHF 35/meter Head+Pump: 75kg

20m riser: 50kg 1.16x0.4x0.35m 3.1x0.15x0.3m

WPUHSURWKAR2 HAND PUMP, submersible, raw water, Kardia K65, 4"

CHF 1’800 CHF 35/meter

Head+Pump: 75kg 20m riser: 50kg

1.16x0.4x0.35m 3.1x0.15x0.3m

Cold chain: No Dangerous: No Regulated: No

General information Lever Operated Lift Pump for up to 60 metres setting in a borehole of 3” to 6”.

- Minimum borehole diameter - 100mm (Kardia K 65)

- Minimum borehole diameter - 80mm (Kardia K 50 VA)

- Maximum borehole diameter - 150mm

Meets V.L.O.M requirements (village level operated maintenance).

Pump performance

- 62 mm cylinder at 36m setting

- Capacity - 0.45 litres/stroke

- Output basis 50 full strokes / minute - 1350 litres/hour

- 50 mm cylinder at 45m setting

- Capacity - 0.28 litres/stroke

- Output basis 50 full strokes / minute - 840 litres/hour

Stainless steel 50mm cylinder for up to 45m setting on special request

Centralisers - required for larger boreholes or wells (special request)

Page 17: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

332 Water and Sanitation

Specifications Pump Cylinder Assembly - PVC body & end caps. PVC / Stainless Steel Plunger fitted rubber cup washer. PVC foot and discharge valve plates. Large diameter suction tube reduces sand intake into cylinder. Lever Operated Lift Pump. Drive Head Galvanised fabricated mild steel head with stainless steel fixings. Long & heavy handle bar to counter balance the connecting rod weight. Welded on bearing block with ball races which can be lubricated. PVC delivery cup located in bracket to connect SBF-KATUR pipe system. Pump head cover secured with one screw to help exclude well pollution. General Complete set of operator manuals in English. 48 mm Ø PVC ‘KATUR’ corrosion proof rising main in standard 3m lengths. 10.8mm Ø x 3m stainless steel pump rods with M12 threaded couplers Separate assemblies of pump cylinder and drive head Stroke length 150mm Installation & Maintenance Tool Kit including special tools & spanners Special foundation frame in galvanised steel. 1 years spare parts kit

Kit content list HAND PUMP, submersible, raw water, Kardia K50VA, 4" Pump head + foundation frame Pump cylinder Kardia K50VA Risers in length of 3m, 1m, or 0.5m, including the rods Optional centralizers Tool set, standard installation tool set in a metal box Tool set, special installation tool, installation clamp for riser pipe Tool set, maintenance set HAND PUMP, submersible, raw water, Kardia K65, 4" Pump head + foundation frame Pump cylinder Kardia K65 Risers in length of 3m, 1m, or 0.5m, including the rods Optional centralizers Tool set, standard installation tool set in a metal box Tool set, special installation tool, installation clamp for riser pipe Tool set, maintenance set

Page 18: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 333

Kit, pump, submersible, borehole testing, + generator

Code Description Ind. price Ship. weight Ship. Vol. KWATPUMERW05 KIT, PUMP+GENSET, subm., borehole

testing, 7.5m3/h at 60m CHF 17’880 630kg 1.6x1.6x1.65m

Total vol.4.25m³ KWATPUMERW04 KIT, PUMP+GENSET, subm., borehole

testing, 5m3/h at 100m CHF 20’250 660kg 1.6x1.6x1.65m

Total vol.4.25m³ Cold chain: No Dangerous: No Regulated: No

General information Kit for testing boreholes after drilling.

All needed equipment is included in the kit, including the generator Lombardini 6LD435, 5kVA.

Suitable for mounting on pick-up, or 2 wheel high speed trailer (options on request).

Suits minimum borehole of 4 inch.

Low head version: 7.5m³/h at 60m

High head version: 5 m³/hr at 100m

Frequency control from 50Hz to 60Hz needed to ensure full use of testing range of the unit.

Specifications Standard engine/alternator: Lombardini 6LD435 (Diesel)/5kW at 3000 rpm

- Alternative engines: Honda (petrol)/kW at 3600 rpm

- Diesel 4 stroke. Single cylinder. Direct injection. Not turbo charged. Air-cooled. Variable speed control, adjustable frequency from 50 to 60Hz. Recoil manual start. Dry air filter. Exhaust silencer. Oil and fuel filters. Low oil level security cut off. Fuel tank: 4L (=2.5 hours running time). Loss of phase indication. Hour meter.

Centrifugal Multistage Pump in corrosion Resistant construction. Integral non-return valve with controlled leak down. Corrosion resistant high efficiency enclosed impellers. 2.2 kW submersible motor. 4 ” /101mm max. overall diameter.

- Nominal Flow low head version: 7.5m³/h at 60m, max. flow 12.5m³/h at 38m (Shutoff 78m).

- Nominal Flow high head version: 5m3/h at 100m, max. flow 7.8 m³/h at 50m (Shutoff 138m).

Page 19: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

334 Water and Sanitation

Kit content list KWATPUMERW05 KIT, PUMP+GENSET, subm., borehole testing, 7.5m3/h at 60m GENERATOR, diesel, 240/400V tri., 6kVA, 1500rpm PUMP, submersible, type BHTV5 1 x Flow Monitoring Unit including: 1 x Pressure gauge 1 x Flowmeter 1 x Control valve 1 x 60m length of flexible rising pipe, 50mm internal diameter 1 x Support drum, for flexible pipe 50mm, up to 60m capacity Riser includes wire support rope, power cable &level gauge system. Head with riser guide & pump setting indication. Storz quick couplings 50m of 50mm NB lay flat surface delivery hose. 5 litre jerrycan (empty).Funnel with filter/gauze. 5 litre supply of engine oil. Maintenance Tool Kit. 500 hour spare parts kit. Complete set of operator manuals in English and/or French. KWATPUMERW04 KIT, PUMP+GENSET, subm., borehole testing, 5m3/h at 100m GENERATOR, diesel, 240/400V tri., 6kVA, 1500rpm PUMP, submersible, type BHTV8 1 x Flow Monitoring Unit including: 1 x Pressure gauge 1 x Flowmeter 1 x Control valve 1 x 110m length of flexible rising pipe, 38mm internal diameter 1 x Support drum, for flexible pipe 50mm, up to 110m capacity Riser includes wire support rope, power cable &level gauge system. Head with riser guide & pump setting indication. Storz quick couplings 50m of 50mm NB lay flat surface delivery hose. 5 litre jerrycan (empty).Funnel with filter/gauze. 5 litre supply of engine oil. Maintenance Tool Kit. 500 hour spare parts kit. Complete set of operator manuals in English and/or French

Page 20: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 335

Kit, pump, submersible, for borehole, + generator

Code Description Ind. price Ship. weight Ship. Vol. KWATPUMERW01 KIT, PUMP + GENSET, subm., for

borehole, high flow, 25m3/60m CHF 16’000 1 pallet box

650kg 1.56x0.86x1m

Total vol.1.35m³ KWATPUMERW02 KIT, PUMP + GENSET, subm.,

borehole, medium flow, 14m3/110m CHF 16’000 1 pallet box

650kg 1.56x0.86x1m

Total vol.1.35m³ KWATPUMERW03 KIT, PUMP + GENSET, subm., for

borehole, low flow, 6m3/220m CHF 1’6000 1 pallet box

650kg 1.56x0.86x1m

Total vol.1.35m³ Cold chain: No Dangerous: No Regulated: No

General information This kit includes all items needed to install and run the pump, including the generator.

Suits minimum borehole diameter of 6 inch. Can be horizontally mounted (with suction shroud) in sump or used as in-line booster.

Choose high flow, medium flow or low flow according to the above chart.

Specifications Standard engine: Lombardini 11LD626.3 (Diesel)/ 14 kW at 1500 rpm

- Alternative engines: Lister TS3 (Diesel)/14.2kW at 1500 rpm

Hatz 2m41 (Diesel)/14.8 kW at 1500 rpm

- Diesel 4 stroke. 3 cylinders. Direct injection. Not turbo charged. Air-cooled. Variable speed control. Electric start. Dry air filter Lister and Hatz. Oil bath air filter Lombardini. Exhaust silencer. Oil and fuel filters. Low oil level security cut off. Fuel tank: 13.5L (= 2.5 hours running time). Hour counter. Skid base with anti-vibration mounts. Lifting /dragging position on each corner.

Centrifugal multistage pump in corrosion resistant construction. Low/Medium/High Flow standard liquid ends. Integral non-return Valve. Corrosion resistant high efficiency enclosed impellers. 7 kW rewindable submersible motor with mechanical seal.

Direct On Line Start Control Panel. Voltmeter, Ammeter, and Frequency meter Low Level cut out probes with signal cable and relays.

Page 21: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

336 Water and Sanitation

Kit content list Generator diesel 14kw Submersible pump 7kw Submersible cable with plug, length according to kit type (270m or 140m or 80m) Control panel Electrode set, high and low level + cables, length according to kit type (270m or 140m or 80m) 20 litre steel jerrycan Funnel, Ø: 200mm, for fuel, flexible neck + metallic filter 5 litre supply of engine oil Engine fuel filter element (according to the type of engine) Engine oil filter element (according to the type of engine) Engine air filter element (according to the type of engine) Complete set of operator manuals in English and French Maintenance Tool Kit. 2000 hours spare parts kit Wooden pallet box, 1 side ramp shape (with logo on request)

Page 22: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 337

Kit, pump, submersible, dewatering, 2", low voltage 110V

Code Description Ind. price Ship. weight Ship. Vol. KWATPUMKDR01 KIT, PUMP, submersible, dewatering,

2", low voltage 110V CHF 9’500 285kg 1.21x0.76x0.97m

Total vol. 0.9m³ Cold chain: No Dangerous: No Regulated: No

General information This kit allows dewatering or cleaning of wells or any type of digging during their construction. It

includes an electric low voltage pump and the adapted generator. Other low voltage equipment including low voltage cleaning pump may be ordered as per the options below.

Electrical submersible pump with 2 inch inlet and outlet.

- Powered by a standard generator fitted with a LOMBARDINI 6LD435 diesel of 5kW.

- Specify the type of engine on your order if different from the Lombardini type.

Suitable for construction and cleaning of maximum 25 m deep well.

- minimum 350mm diam (14 ”)

- Max pump submergence 20m

Specifications Power generating set

- Standard engine: Lombardini 6LD435 (Diesel)/5 kW at 3000 rpm

- Alternative engines: Briggs and Stratton (Petrol)/ kW at 000 rpm

Honda (Petrol)/ kW at 000 rpm

- Diesel 4 stroke. Single cylinder. Direct injection. Not turbo charged. Air-cooled. Variable speed control. Recoil manual start. Dry air filter. Exhaust silencer. Oil and fuel filters. Low oil level security cut off. Fuel tank: (= 2.5 hours running time). Fitted Hour Meter.

- Low voltage power 110V for safety.

- Engine close coupled with alternator wired for dual low voltages for safe duty.

Page 23: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

338 Water and Sanitation

- Power circuit and earth leakage protected weatherproof output sockets.

- Safety 220 volt 3 phase with 3 x 120 volt single phase outputs for ancillaries.

- Secured by anti-vibration mounts inside rollover frame with 2 wheel site trolley

Dewatering / Cleaning Pump

- Positive Displacement Drainage Pump 110v -continuous dry running.

- Max Solids Handling 7mm.

- High head Centrifugal Pump with 1.85 kW safety submersible motor.

- Mounted on fabricated steel lowering frame base with mesh guard.

- Wall jetting/washing element with control valve, strainer &drop hose.

Kit content list 1 x Generator, diesel, 110V / 5KW, Lombardini 6LD435 1 x PUMP, submersible, drainage, electrical, 1.8kW 1 x 30m of Royproof cable with fitted plugs 1 x Complete set of operator manuals in English and/or French. 1 x 3m x 32mm suction hose with hose clips 1 x 30m x 25mm delivery hose with hose clips 1 x 30 m x 2 ” lay flat PVC delivery hose with rope &2 ” STORZ quick coupling. 1 x 20 m x 2 ” lay flat PVC delivery waste hose with 2 ” STORZ quick coupling. 1 x 5 litre jerrycan for Petrol or 20 litre for Diesel version (empty). 1 x Funnel with filter/gauze 1 x 5 litre supply of engine oil. 1 x Maintenance Tool Kit 500 hour Lombardini 6LD435 spare parts kit Or Honda spare part kit Or Briggs and Stratton spare part kit 1 x Wooden box with Red Cross /Crescent logo painted in red on white background.

Options - Accessories Low voltage (110v) Air Ventilation Blower with 30m x 2 ”hose Low voltage (110v) Rockbreaking Low voltage (110v) Drilling Tool sets Low voltage (110v) Power Lifting Modules Low voltage (110v) high pressure pump for cleaning.

Page 24: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 339

Kit, pump, electrical, drainage, 2", 15m3/h at 15m

Code Description Ind. price Ship. weight Ship. Vol. KWATPUMEDR02 KIT, PUMP, electrical, drainage wat.

50mm, 2", 15m3/h at 15m CHF 7’000 1 parcel

200kg 1.11x0.76x1m

total vol. 0.85m³ Cold chain: No Dangerous: No Regulated: No

General information Electrical pump 2 inch /1.85 kW with Diesel Generator Lombardini 6LD400 engine.

- Specify the type of engine on your order if different from the Lombardini type.

This pump accepts water with solids up to 50mm diameter, raw water, sewage.

Specifications Standard engine: Lombardini 6LD435 (Diesel)/5.5 kW at 3000 rpm.

- Alternative engines: Briggs and Stratton Vanguard (petrol)/6kW at 3000rpm

Lister LT1 (Diesel)/5.6kW at 3000 rpm

Hatz 1B40-1 (Diesel)/6.2 kW at 3000 rpm.

- Petrol or diesel 4 strokes. Single cylinder. Not turbo charged. Air-cooled. Variable speed control. Recoil manual start. Dry air filter. Exhaust silencer. Oil & fuel filters. Low oil level security shutdown. Hour counter. Fuel tank: 4lt (= 3 hours running time).

Alternator with circuit braker, earth leakage strip. Auto inducted, single bearing, brushless.

Engine close coupled with alternator. Mounted on anti-vibration mounts inside robust tubular steel roll over frame, with 2 wheels.

Pump suitable raw water supply, desludging, dewatering & sewage pumping. Single stage centrifugal solids handling pump in cast iron construction. Cast iron high efficiency & clog resistant (sewage type) open impeller. Tandem mechanical seals running in oil bath. Maximum solids handling 50mm. Free standing with cook anti-dive plate. Fitted 25m royproof cable & plug plus 20m extension cable with connectors.

Page 25: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

340 Water and Sanitation

Kit content list 1 x Electrical pump, end-suction, drainage, gen. purpose, solid handling 50mm, 2”/5.5kW 1 x Generator, Lombardini 6LD435, 220V/5.5kW 1 x Complete set of operator manuals in English and/or French 1 x 20 m 2 ” lay flat PVC delivery hose with ‘Storz’ coupling and sliding collar 1 x 20 m rope 1 x 5L engine oil 1 x 20L steel jerrycan in diesel version, or 5lt plastic jerrican in petrol version 1 x Funnel with filter/gauze 1 x spare parts kit: Standard Lombardini engine spare parts kit including 1 x Wooden box with Red Cross /Crescent logo painted in red on white background.

Page 26: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 341

Kit, motor pump, sludge, diaphragm, diesel, 4”, 25m3/h at 10m

Code Description Ind. price Ship. weight Ship. Vol. KWATPUMCSL01 KIT, MOTOR PUMP, sludge,

diaphragm, diesel, 4", 25m3/h a 10m CHF 13’000 1 parcel

380kg 1.66x1.66x1.14m Total vol.3.15m³

Cold chain: No Dangerous: No Regulated: No

General information Self-priming diaphragm sludge pump 4 inch / 5 kW with Lombardini 6LD325 engine.

- Specify the type of engine on your order if different from the Lombardini type.

Mainly used for emptying latrines.

- 4 “ suction hose will pass through pit latrine squatting plate aperture

- Capacity also suitable for filling small waste containers (i.e. Oil Drums).

Continuous dry running. Dry self-priming from 7m.

Specifications Standard engine: Lombardini 6LD325 / 4.2 kW at 3000 rpm.

- Alternative engines: Lister AC1 / 4.5kW at 3000 rpm

Yanmar L100 / 4.5kW at 3000 rpm

Hatz 1B30-1 / 4.5 kW at 3600 rpm.

- Diesel 4 stroke. Single cylinder. Direct injection. Not turbo charged. Air-cooled. Variable speed control. Recoil manual start. Dry type air filter. Exhaust silencer. Oil & fuel filters. Oil level shutdown. Fuel tank: 4lt (= 5 hours running time).

Simplex diaphragm self-priming pump in aluminium construction. Cast iron (wetted parts). Suction & delivery flap valves. Suction air chamber. 4” screwed BSP suction /discharge connections. Neoprene diaphragm. Max solids handling 60mm.

Engine close coupled with pump on skid base with anti-vibration mounts 2-wheel site trolley.

Page 27: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

342 Water and Sanitation

Kit content list 1 x Pelican DLO 100 pump coupled with diesel engine, on 2 wheel trailer 2 x COUPLING, half symmetrical, ‘Storz’, threaded male 1 x JH Suction lance 1 x 6m of 4” reinforced suction spiraled hose fitted with 2 Storz coupling and band clips 1 x 20m of 4” reinforced delivery flat hose fitted with 2 Storz coupling and band clips 1 x 5l engine oil, diesel engine 1 x 20l steel jerrycan 1 x Funnel, plastic, with built in filter 1 x Maintenance Tool Kit including: 1 x 2,000 hours Lombardini spare parts kit including: 8 x Engine oil sump plug washer 8 x Oil filter element 8 x Fuel filter element 4 x Engine rocker box gasket 4 x Engine injection washer 8 x Engine leak-off pipe washer Or 2000 hours Lister spare parts kit Or 2000 hours Hatz spare parts kit Or 2000 hours Yanmar spare parts kit 1 x Engine operator manual in English and French 1 x Pump operator manual in English and French 1 x Wooden box with Red Cross /Crescent logo painted in red on white background.

Page 28: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 343

Kit, motor pump, sludge, diaphragm, diesel, 3”, 15m3/h at 10m

Code Description Ind. price Ship. weight Ship. Vol. KWATPUMCSL02 KIT, MOTOR PUMP, sludge,

diaphragm, diesel, 3", 15m3/h a 10m CHF 4’300

Cold chain: No Dangerous: No Regulated: No

General information Self-priming diaphragm sludge pump 3 inch / 1.5 kW with Lombardini 15LD225 engine.

- Specify the type of engine on your order if different from the Lombardini type.

Mainly used for emptying latrines.

- 3 “ suction hose will pass through pit latrine squatting plate aperture

- Capacity also suitable for filling small waste containers (i.e. Oil Drums).

Continuous dry running. Dry self-priming from 7m.

Specifications Standard engine: Lombardini 15LD225 / kW at 3000 rpm.

- Alternative engines: Hatz LB20-1 / kW at 3600 rpm.

- Diesel 4 stroke. Single cylinder. Direct injection. Not turbo charged. Air-cooled. Variable speed control. Recoil manual start. Dry type air filter. Exhaust silencer. Oil & fuel filters. Oil level shutdown. Fuel tank: 4lt (= 4 hours running time).

Simplex diaphragm self-priming pump in aluminium construction. Cast iron (wetted parts). Reduction 1/43. Elastic connecting rod with protection against blocking. Suction and delivery flap valves. Suction air chamber. 3” screwed BSP suction /discharge connections. Neoprene diaphragm. Max solids handling 60mm.

Engine close coupled with pump on skid base with anti-vibration mounts 2-wheel site trolley.

Page 29: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

344 Water and Sanitation

Kit content list 1 x Libellula 1-3” pump coupled with diesel engine, on 2 wheel trailer 2 x COUPLING, half symmetrical, ‘Storz’, threaded male 1 x JH Suction lance 1 x 6m of 3” reinforced suction spiraled hose fitted with 2 Storz coupling and band clips 1 x 20m of 3” reinforced delivery flat hose fitted with 2 Storz coupling and band clips 1 x 5l engine oil, diesel engine 1 x 20l steel jerrycan 1 x Funnel, plastic, with built in filter 1 x Maintenance Tool Kit including: 1 x 2,000 hours Lombardini spare parts kit including: 8 x Engine oil sump plug washer 8 x Oil filter element 8 x Fuel filter element 4 x Engine rocker box gasket 4 x Engine injection washer 8 x Engine leak-off pipe washer Or 2000 hours Hatz spare parts kit 1 x Engine operator manual in English and French 1 x Pump operator manual in English and French 1 x Wooden box with Red Cross /Crescent logo painted in red on white background.

Page 30: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 345

Kit, pump, submersible, sewage, max. 40 m3/h, max.20m + generator 6KVA

Code Description Ind. price Ship. weight Ship. Vol. KWATPUMESE01 KIT, PUMP, SUBM.sewage, max. 40

m3/h, max.20m + GENSET 6KVA CHF 5’500

Cold chain: No Dangerous: No Regulated: No

General information Vortex type submersible electric pump 3.4kW with diesel generator Lombardini 6LD435, 5.5kVA.

Vortex wheel has a low efficiency but is able to ingest every material, including fibrous. It is highly adapted for sewage where all types of material can be found.

Specifications Standard engine: Lombardini 6LD435 (Diesel)/5 kW at 3000 rpm.

- Alternative engines: Briggs and Stratton Vanguard (petrol)/6kW at 3000rpm

Lister LT1 (Diesel)/5.6kW at 3000 rpm

Hatz 1B40-1 (Diesel)/6.2 kW at 3000 rpm.

- Petrol or diesel 4 strokes. Single cylinder. Not turbo charged. Air-cooled. Variable speed control. Recoil manual start. Dry air filter. Exhaust silencer. Oil & fuel filters. Low oil level security shutdown. Hour counter. Fuel tank: 4lt (= 3 hours running time).

Alternator with circuit breaker, earth leakage strip. Auto inducted, single bearing, brushless.

Engine close coupled with alternator. Mounted on anti-vibration mounts inside robust tubular steel roll over frame, with 2 wheels.

Vortex pump ABS M26-2D, 3.4kW, 9m3 at 20m, 40m3 at 9m, 40kg, or

Vortex pump KSB Amarex F65-210/130, 3.4kW, 10m3 at 20m, 40m3 at 10m, 60kg

Kit content list Generator Lombardini 6kVA Pump, vortex type, electrical submersible, 3.4kW, 10m³/20m Electrical submersible cable fitted to the pump, 25m Stainless steel royproof cable, 25m

Page 31: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 347

Flexible water tanks, onion type

Code Description Ind. price Ship. weight Ship. Vol. KWATTANKO10 KIT, WATERTANK, flexible onion,

10 m3, storage CHF2’890 115kg 1.3x0.9x0.9m

Total vol.1.05m³ KWATTANKO20 KIT, WATERTANK, flexible onion,

20 m3, storage 148kg 1.2x1.25x0.65m

Total vol.0.98m³ Cold chain: No Dangerous: Yes-Repair kit Regulated: Yes-Repair kit-IATA

General information Flexible water tank, open top, fast setting up, light and small volume for transport.

Specifications Heavy duty drinking water quality PVC coated polyester 2 x 2”BSP threaded outlet (ICRC standard) 2 x 3”BSP threaded outlet (Federation ERU standard) Anti chafe patches and flaps PVC cover with fixing hasps and ropes Packaging as per IATA regulation UN1133 (for the glue) and UN1263 (for the thinner)

Kit content list KWATTANKO10 KIT, WATERTANK, flexible onion, 10 m3, storage X KWATTANKO20 KIT, WATERTANK, flexible onion, 20 m3, storage X WWAKFLOT10 WATERTANK, FLEXIBLE ONION, storage, 10 m3 1

WWAKFLOT20 WATERTANK, FLEXIBLE ONION, storage, 20 m3 1

WWAKFLOT10GS (onion tank 10m3) GROUND SHEET 1

WWAKFLOT20GS (onion tank 20m3) GROUND SHEET 1

WNECGACR2M11/2F COUPLING, GALVA, REDUCER, bush, 2"-11/2", thread male/fem 2 2

WNECGACR11/2M1F COUPLING, GALVA, REDUCER, bush, 1.1/2"-1", thread male/fem 1 1

WNECGANN2M2M COUPLING, GALVA, NIPPLE, 2", threaded male/male 1 1

WNECGATT2FFF COUPLING, GALVA, TEE, 2", threaded fem/fem/fem 1 1

WNECGAUU2M2F COUPLING, GALVA, UNION, 2", 3 pieces, male/fem 1 1

Page 32: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

348 Water and Sanitation

WNECSTCC2SM COUPLING, half symetrical, 'Storz', 2", threaded male 2 2

WNECSTCP2 COUPLING, half symmetrical 'Storz', 2", plug with chain 1 1

WNECSTGA2 (coupling half sym. Storz) GASKET, 2" 2 2

WTOOSEALTEFL SEAL TAPE, 'Teflon', for water connectors, roll 12mm x 12m 1 1

WNECSTCC2SH COUPLING, half symetrical, 'Storz', 2", hose tail 2 2

WNEABACL50-70 BAND CLIP, high pressure, 50-70mm 6 6

WNEVBRGA2FF VALVE, GATE, 2”, brass, threaded fem/fem 1 1

WNEVBRBA1FS VALVE, BALL, 1”, brass, 1/4 turn, thread male/angled spout 1 1

WNECSTHO2-3 (coupling half sym. Storz) HOOK SPANNER, 2"-3" 1 1

KWATREPAF01 KIT, REPAIR, for PVC flexible reinforced material 1 1 Included in both kits above: KWATREPAF01 KIT, REPAIR, for PVC flexible reinforced material EHDWGLUEN01 GLUE, "Neoprene contact", 100 g, tube 1

EHDWGLUETH1 THINNER, trichlo-ethylene, per litre 1

EHDWPAPSD12 SAND PAPER, dry use, for wood, fine, n°120, A4 sheet 1

WWAKREPAPVSH SHEET, PVC, for flexible PVC watertank repair, 1 x 0.5m 1

APACIATAC01 CONTAINER, IATA, for PVC flexible watertank repair kit 1

Page 33: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 349

Flexible water tanks, bladder type

Code Description Ind. price Ship. weight Ship. Vol. KWATTANKP01 KIT, WATERTANK, flexible pillow,

1m3, storage CHF 780 22kg 0.61x0.61x0.61m

Total vol.0.23m³ KWATTANKP10 KIT, WATERTANK, flexible pillow,

10m3, storage CHF 1’680 64kg 1.2x0.61x0.61m

Total vol.0.45m³ KWATTANKP15 KIT, WATERTANK, flexible pillow,

15m3, storage CHF 2’160 82kg 1.2x0.8x0.61m

Total vol.0.59m³ Cold chain: No Dangerous: Yes-Repair kit Regulated: Yes-Repair kit-IATA

General information Flexible water tank, fast setting up, light and small volume for transport.

Specifications Heavy duty drinking water quality PVC coated polyester Inner coating with HPU (polyurethane) or food contact PVC 2 x 2”BSP threaded outlet (ICRC standard) 2 x 3”BSP threaded outlet (Federation ERU standard) Anti chafe patches. Over pressure relief valves with rubber plugs. Packaging as per IATA regulation UN1133 (for the glue) and UN1263 (for the thinner)

Kit content list KWATTANKP01 KIT, WATERTANK, flexible pillow, 1m3, storage X KWATTANKP10 KIT, WATERTANK, flexible pillow, 10m3, storage X KWATTANKP15 KIT, WATERTANK, flexible pillow, 15m3, storage X WWAKFLPT01 WATERTANK, FLEXIBLE PILLOW, PVC, 1m3, for storage 1 _ _

WWAKFLPT10 WATERTANK, FLEXIBLE PILLOW, PVC, 10m3, for storage _ 1 _

WWAKFLPT15 WATERTANK, FLEXIBLE PILLOW, PVC, 15m3, for storage _ _ 1

WWAKFLPT01GS GROUNDSHEET, for flexible pillow tank 1m3 1 _ _

WWAKFLPT10GS GROUNDSHEET, for flexible pillow tank 10m3 _ 1 _

WWAKFLPT15GS GROUNDSHEET, for flexible pillow tank 15m3 _ _ 1

WNECGACR2M11/2F COUPLING, GALVA, REDUCER, bush, 2"-11/2", thread male/fem 2 2 2

Page 34: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

350 Water and Sanitation

WNECGACR11/2M1F COUPLING, GALVA, REDUCER, bush, 1.1/2"-1", thread male/fem 1 1 1

WNECGANN2M2M COUPLING, GALVA, NIPPLE, 2", threaded male/male 1 1 1

WNECGATT2FFF COUPLING, GALVA, TEE, 2", threaded fem/fem/fem 1 1 1

WNECGAUU2M2F COUPLING, GALVA, UNION, 2", 3 pieces, male/fem 1 1 1

WNECSTCC2SM COUPLING, half symetrical, 'Storz', 2", threaded male 2 2 2

WNECSTCP2 COUPLING, half symmetrical 'Storz', 2", plug with chain 1 1 1

WNECSTGA2 (coupling half sym. Storz) GASKET, 2" 2 2 2

WTOOSEALTEFL SEAL TAPE, 'Teflon', for water connectors, roll 12mm x 12m 1 1 1

WNECSTCC2SH COUPLING, half symetrical, 'Storz', 2", hose tail 2 2 2

WNEABACL50-70 BAND CLIP, high pressure, 50-70mm 6 6 6

WNEVBRGA2FF VALVE, GATE, 2”, brass, threaded fem/fem 1 1 1

WNEVBRBA1FS VALVE, BALL, 1”, brass, 1/4 turn, thread male/angled spout 1 1 1

WNECSTHO2-3 (coupling half sym. Storz) HOOK SPANNER, 2"-3" 1 1 1

KWATREPAF01 KIT, REPAIR, for PVC flexible reinforced material 1 1 1 Included above: KWATREPAF01 KIT, REPAIR, for PVC flexible reinforced material EHDWGLUEN01 GLUE, "Neoprene contact", 100 g, tube 1

EHDWGLUETH1 THINNER, trichlo-ethylene, per litre 1

EHDWPAPSD12 SAND PAPER, dry use, for wood, fine, n°120, A4 sheet 1

WWAKREPAPVSH SHEET, PVC, for flexible PVC watertank repair, 1 x 0.5m 1

APACIATAC01 CONTAINER, IATA, for PVC flexible watertank repair kit 1

Page 35: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 351

Flexible tank for water transport, 5m3, bladder type

Code Description Ind. price Ship. weight Ship. Vol. KWATTANKP05T

KIT, WATERTANK,FLEXIBLE, PILLOW, for transport, 5 m3, +harn.

CHF1’950 1 parcel 50kg

0.80x0.61x0.61m vol. 0.3m3

Cold chain: No Dangerous: Yes-Repair kit Regulated: Yes-Repair kit-IATA

General information Heavy-duty bladder tank to fit on a flat bed truck, or to use as a normal storage tank

Size of the truck bed should be minimum 4m long by 2m wide.

Truck with low side body panels is preferable to a totally open truck bed.

The tank is fitted with heavy duty 50mm polyester straps

Specifications Heavy duty drinking water quality PVC coated polyester Construction special for high pressure resistance when used as truck tanker 2 x 2”BSP threaded outlet (ICRC standard) 2 x 3”BSP threaded outlet (Federation ERU standard) Fitted minimum with 2 heavy duty polyester webbing straps plus 2 straps per end Straps terminated with eye and/or loops for securing. Anti chafe patches. Over pressure relief valves with rubber plugs. Packaging as per IATA regulation UN1133 (for the glue) and UN1263 (for the thinner)

Kit content list Code Description Qty WWAKFLPT05T WATERTANK, flexible pillow, PVC, 5 m3, transport/storage 1

WWAKFLPT05TH HARNESS, for flexible pillow tank 5m3 1

WWAKFLPT05GS GROUNDSHEET, for flexible pillow tank 5m3 1

WNECGACR2M11/2F COUPLING, GALVA, REDUCER, bush, 2"-11/2", thread male/fem 2

WNECGACR11/2M1F COUPLING, GALVA, REDUCER, bush, 1.1/2"-1", thread male/fem 1

WNECGANN2M2M COUPLING, GALVA, NIPPLE, 2", threaded male/male 1

WNECGATT2FFF COUPLING, GALVA, TEE, 2", threaded fem/fem/fem 1

Page 36: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

352 Water and Sanitation

WNECGAUU2M2F COUPLING, GALVA, UNION, 2", 3 pieces, male/fem 1

WNECSTCC2SM COUPLING, half symetrical, 'Storz', 2", threaded male 2

WNECSTCP2 COUPLING, half symmetrical 'Storz', 2", plug with chain 1

WNECSTGA2 (coupling half sym. Storz) GASKET, 2" 2

WTOOSEALTEFL SEAL TAPE, 'Teflon', for water connectors, roll 12mm x 12m 1

WNECSTCC2SH COUPLING, half symetrical, 'Storz', 2", hose tail 2

WNEABACL50-70 BAND CLIP, high pressure, 50-70mm 6

WNEVBRGA2FF VALVE, GATE, 2”, brass, threaded fem/fem 1

WNEVBRBA1FS VALVE, BALL, 1”, brass, 1/4 turn, thread male/angled sprout 1

WNECSTHO2-3 (coupling half sym. Storz) HOOK SPANNER, 2"-3" 1

KWATREPAF01 KIT, REPAIR, for PVC flexible reinforced material 1 Included above: KWATREPAF01 KIT, REPAIR, for PVC flexible reinforced material EHDWGLUEN01 GLUE, "Neoprene contact", 100 g, tube 1

EHDWGLUETH1 THINNER, trichlo-ethylene, per litre 1

EHDWPAPSD12 SAND PAPER, dry use, for wood, fine, n°120, A4 sheet 1

WWAKREPAPVSH SHEET, PVC, for flexible PVC watertank repair, 1 x 0.5m 1

APACIATAC01 CONTAINER, IATA, for PVC flexible watertank repair kit 1

Options - Accessories Red Cross Tapstands Water pipes Coupling

Page 37: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 353

Repair kit, for flexible water tank

Code Description Ind. price Ship. weight Ship. Vol. KWATREPAF01 KIT, REPAIR, for flexible tank PVC

reinforced material CHF44.00 1kg 0.1 x 0.15 x 0.2m

Cold chain: No Dangerous: Yes Regulated: Yes - IATA

General information Repair kit for flexible water tanks of PVC coated polyester material (= usual PVC tank material).

The glue is neoprene specific for PVC sheet, and is totally different from the PVC pipe glue.

The thinner is usually acetone, can also be thricloethylene. Highly flammable item.

Thinner must be packed in a safe unbreakable container, and is subject to transport regulation.

Specifications As per individual item specifications. Packing as per IATA regulation for UN codes: Glue: UN 1133 Thinner: UN 1263

Kit content list Code Description Qty EHDWGLUEN01 GLUE, "Neoprene contact", 100 g, tube 1

EHDWGLUETH1 THINNER, trichlo-ethylene, per litre 1

EHDWPAPSD12 SAND PAPER, dry use, for wood, fine, n°120, A4 sheet 1

WWAKREPAPVSH SHEET, PVC, for flexible PVC watertank repair, 1 x 0.5m 1

APACIATAC01 CONTAINER, IATA, for PVC flexible watertank repair kit 1

Page 38: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 355

Rigid water tank, corrugated steel sheets + liner

Code Description Ind. price Ship. weight Ship. Vol. KWATTANKR10 KIT, WATER TANK, 10 m3, rigid,

corrugated CHF 2’714 310kg 1.65x0.95x0.65m

Total vol.1.02m³ KWATTANKR45 KIT, WATER TANK, 45 m3, rigid,

corrugated CHF5’400 3 parcels

282kg 252kg 78kg Total 612kg

2.9x0.8x0.58m 1.33x0.92x0.86m 1.36x0.64x0.48m Total vol.2.82m³

KWATTANKR70 KIT, WATER TANK, 70 m3, rigid, corrugated

CHF6’500 3 parcels 402kg 284kg 79kg

Total 765kg

2.9x0.8x0.58m 1.33x0.92x0.86m 1.36x0.64x0.48m Total vol.2.82m³

KWATTANKR95 KIT, WATER TANK, 95 m3, rigid, corrugated

CHF7’100 3 parcels 480kg 321kg

100kg Total 901kg

2.9x0.9x0.6m 1.33x0.92x0.86m 1.36x0.64x0.48m Total vol.3.04m³

Cold chain: No Dangerous: Yes- repair kit Regulated: Yes – Repair kit

General information Rigid water tank, fast erection, light and small volume for transport (compared to final capacity).

The corrugations of the steel sheets give rigidity to the tank. Other types made of flat plain sheets are not recommended. The sheets for the 10m³ are specific to this model. The sheets for the 45, 70 and 95m³ are similar in shape and size.

To install the tanks, the appropriate tools are always delivered with the tank kit (code KWATTANKRTO1). To connect the tanks together and to the network, order the standard set of fittings (code KWATTANKRFI3).

Page 39: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

356 Water and Sanitation

Where possible erect tanks in elevated positions to allow gravity distribution.

Ensure stability of tanks, particularly when empty or in high winds by using guy ropes and by banking earth around the lower sections of the tanks.

Use tank roof covers and keep them well lashed down.

Specifications Corrugated galvanized iron sheet Each tank has 3 outlet holes for 3” connector. One of these holes has a blanking plate fitted. EPDM synthetic rubber liner, 1.4mm thick, reinforced, welded, to fit d: 6.4m tank The liner allows 300mm turndown on outside with 4 eyelets spaced at 1m centres around edge Connector flanges to be pre-assembled with studs, bolts, washers, and gaskets PVC coated polyester roof Base plate for roof supporting column has countersunk holes to prevent damaging the lining by friction with the bolt heads. Bolts and nuts are all zinc plated for high corrosion resistance Spanners of good quality for intensive use

Kit content list KWATTANKR10 KIT, WATER TANK, 10 m3, rigid, corrugated Pack 1: STEEL KIT WWAKRTOXIS03 IRON SHEET, corrugated, for rigid tank 10m3 15

WWAKRTOXIS04 IRON SHEET, corrugated, for rigid tank 10m3, + outlets 3

Pack 2: LINER KIT WWAKRTOXCA12 SPLIT CAPPING, PVC, d:12mm, per metre length 8

WWAKRTOXCA25 SPLIT CAPPING, PVC, d:25mm, per metre length 8

EHDWCLIP25 CLIP, spring clips, 25mm 25

EHDWBOLTGR01 BOLT, galva, round head with slot drive, d:10mm, L:20mm 410

EHDWNUTSG10- NUT, galva, hexagonal, d:10mm, size: 17mm 410

EHDWWASHF10 WASHER, galva, flat, d:10mm 410

ETOOPODG01 PODGER, spike to align iron sheet bolt holes 1

WNEVBRGA3FF VALVE, GATE, brass, 3", tread fem/fem 1

APACSCOT50RB TAPE, adhesive, canvas reinforced, 55mm, roll 50m, black 1

WNECIRFL3ASS CONNECTOR, FLANGE ASSEMBLY, 3”, complete set 2

Each including:

- WNECIRFL3M90 CONNECTOR, 3”, pipe L:90mm threaded male, flanged, 4 x M10 1

- WNECIRFL3M FLANGE, counterplate, 3”, 4 plain holes d: 10mm 1

- WNECIRFL3G (3" flange) GASKET, 2mm thick rubber, 4 holes 10mm 2

- EHDWBOLTS161 STUD, galva, d:16mm, L: 100mm 4

- EHDWNUTSG16- NUT, galva, hexagonal, d: 16mm, size: 24mm 8

- EHDWWASHF16 WASHER, galva, flat, d:16mm 8

WWAKRTOXL10 LINING, 10m3, EPDM reinforced synth. rubber, thick: 1.25mm 1

Page 40: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 357

KWATREPAEPLI REPAIR KIT, for rigid water tank EPDM rubber liners 1

Including:

- WWAKREPAEPSH EPDM MATERIAL SPARE, 1 x 1m 1

- WWAKREPAEPTA ADHESIVE TAPE, to repair EPDM liners, 50mm x 10m 1

WTOOSEALTEFL SEALING TAPE, 'Teflon', for water connectors, roll 12mm x 12m 1

WNEABACL077 BAND CLIP, high pressure, 77-95mm 1

WNECBRCA3F3T COUPLING, BRASS, ADAPTOR, 2 pces, thr. fem. 3"/hose tail 3" 1

WWAKRTOXGUIDE MANUAL, Oxfam Water Storage Pack, in a plastic bag 1

Pack 3: ROOF KIT WWAKRTOXRO10 ROOF, 10 m3 rigid tank, PVC coated polyester, + eyelets 1

WWAKRTOXROS1 ROOF SUPPORT ASSEMBLY, for 10m3 rigid tank 1

HSHEROPE06P ROPE, polypropylene, black, d:6mm, per metre length 100

EHDWVHDWEY10 EYE NUT, M10 12

KWATREPAF01 KIT, REPAIR, for PVC flexible reinforced material 1 KWATTANKR45 KIT, WATER TANK, 45 m3, rigid, corrugated X KWATTANKR70 KIT, WATER TANK, 70 m3, rigid, corrugated X KWATTANKR95 KIT, WATER TANK, 95 m3, rigid, corrugated X Pack 1: KIT STEEL 45m³ 70m³ 95m³

WWAKRTOXIS01 IRON SHEET, corrugated, for rigid tank 45/70/95m3 11 18 25

WWAKRTOXIS02 IRON SHEET, corrugated, for rigid tank 45/70/95m3, + outlets 3 3 3 Pack 2: KIT LINER +ACCESSORIES 45m³ 70m³ 95m³ WWAKRTOXCA12 SPLIT CAPPING, PVC, d:12mm, per metre length 21 21 21

WWAKRTOXCA25 SPLIT CAPPING, PVC, d:25mm, per metre length 21 21 21

EHDWCLIP25 CLIP, spring clips, 25mm 60 60 60

EHDWBOLTGR01 BOLT, galva, round head with slot drive, d:10mm, L:20mm 350 560 780

EHDWNUTSG10- NUT, galva, hexagonal, d:10mm, size: 17mm 350 560 780

EHDWWASHF10 WASHER, galva, flat, d:10mm 350 560 780

ETOOPODG01 PODGER, spike to align iron sheet bolt holes 1 1 1

WNEVBRGA3FF VALVE, GATE, brass, 3", threaded fem/fem 1 1 1

APACSCOT50RB TAPE, adhesive, canvas reinforced, 55mm, roll 50m, black 1 2 2

WNECIRFL3ASS CONNECTOR, FLANGE ASSEMBLY, 3”, complete set 3 3 3

Each including: WNECIRFL3M90 CONNECTOR, 3”, pipe L:90mm threaded male, flanged, 4 x M10 1

WNECIRFL3M FLANGE, counterplate, 3”, 4 plain holes d: 10mm 1

WNECIRFL3G (3" flange) GASKET, 2mm thick rubber, 4 holes 10mm 2

EHDWBOLTS161 STUD, galva, d:16mm, L: 100mm 4

EHDWNUTSG16- NUT, galva, hexagonal, d: 16mm, size: 24mm 8

EHDWWASHF16 WASHER, galva, flat, d:16mm 8 WWAKRTOXL45 LINING, 45m3, EPDM reinforced synth. rubber, thick: 1.25mm 1 0 0

WWAKRTOXL70 LINING, 70m3, EPDM reinforced synth. rubber, thick: 1.25mm 0 1 0

WWAKRTOXL95 LINING, 95m3, EPDM reinforced synth. rubber, thick: 1.25mm 0 0 1

Page 41: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

358 Water and Sanitation

KWATREPAEPLI REPAIR KIT, for rigid water tank EPDM rubber liners 1 1 1

Including: WWAKREPAEPSH EPDM MATERIAL SPARE, 1 x 1m 1

WWAKREPAEPTA ADHESIVE TAPE, to repair EPDM liners, 50mm x 10m 1 WTOOSEALTEFL SEALING TAPE, 'Teflon', for water connectors, roll 12mm x 12m 1 1 1

WWAKRTOXGUIDE MANUAL, Oxfam Water Storage Pack, in a plastic bag 1 1 1 Pack 3: KIT CONICAL ROOF 45m³ 70m³ 95m³ WWAKRTOXRO75 ROOF, PVC coated polyester 500gr/m2, d:7.5m, + 28 eyelets 1 1 1

HSHEROPE06P ROPE, polypropylene, black, d:6mm, per metre length 250 300 300

WWAKRTOXROC1 COLUMN SECTION, plastic, d:100mm, L: 1m 2 3 4

WWAKRTOXTOPL TOP PLATE, for roof central support 2 2 2

WWAKRTOXROCC CONNECTOR, straight, for plastic column d:100mm 1 2 3

EHDWVHDWEY10 EYE NUT, M10 28 28 28

WWAKRTOXBAPL BASE PLATE, for roof central support 1 1 1

KWATREPAF01 KIT, REPAIR, for PVC flexible reinforced material 1 1 1

Options - Accessories KWATTANKRFI3 KIT, TANK LINKING PIPEWORK, 3”, for 3 rigid tanks KWATTANKRTO1 KIT, TOOLS, for rigid corrugated water tanks

Page 42: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 359

Kit, fittings, 3", for 3 rigid corrugated water tanks

Code Description Ind. price Ship. weight Ship. Vol. KWATTANKRFI3 KIT, FITTINGS, 3", for 3 rigid

corrugated water tanks CHF 1’270 159kg 1.23 x 1.24 x 0.4m

Cold chain: No Dangerous: No Regulated: No

General information This kit allows connection between 3 rigid tanks (Oxfam type), and to a network.

This kit works with all type of standard rigid water tanks.

The 30m hose included in the kit allows only the connection of the 3 tanks. Extra hose length should be ordered separately. Hoses can also be found locally.

Specifications See specifications in individual item sheets for pipes, connectors, band clips…

Kit content list Code Description Qty WNECPVTT80FFF COUPLING, PVC, TEE, 3” ND80, NP6, threaded fem/fem/fem 2

WNECPVNN80FF COUPLING, PVC, NIPPLE, 3” ND80, NP6, threaded male/male 11

WNECPVCP80F COUPLING, PVC, CAP, 3” ND80, NP6, threaded fem 2

WNECBRCA3M3T COUPLING, BRASS, ADAPTOR, 2 pces, thr. fem. 3"/hose tail 3" 12

WNEABACL80-100 BAND CLIP, high pressure, 80-100mm 18

WNECCOCP3M90 COUPLING, COMPRESSION, 3”, thread male to pipe d.ext.: 90mm 1

WNECPVEE80FF COUPLING, PVC, ELBOW, 3” ND80, NP6, threaded fem/fem 1

WNEHPVRI8005 PIPE, PVC, 3” ND80, NP6, L: 500mm, threaded male one end 1

WNEHEPSP3-20 HOSE, PVC, SPIRALLED, suction/delivery, 3" x 20m 1

Page 43: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

360 Water and Sanitation

WNECIRFL3M90 CONNECTOR, 3”, pipe L:90mm threaded male, flanged, 4 x M10 1

WNECIRFL3M FLANGE, counterplate, 3”, 4 plain holes d: 10mm 1

WNECIRFL3G (3" flange) GASKET, 2mm thick rubber, 4 holes 10mm 2

EHDWBOLTS161 STUD, galva, d:16mm, L: 100mm 4

EHDWNUTSG16- NUT, galva, hexagonal, d: 16mm, size: 24mm 8

EHDWWASHF16 WASHER, galva, flat, d:16mm 8

WTOOSEALTEFL SEALING TAPE, 'Teflon', for water connectors, roll 10mm x 30m 2

Options - Accessories Pipes Storz couplings

Page 44: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 361

Kit, tool, for rigid watertanks Code Description Ind. price Ship. weight Ship. Vol. KWATTANKRTO1 KIT, TOOLS, for rigid corrugated water

tanks CHF 520 7kg 0.53x0.34x0.19m

Total vol.0.035m³ Cold chain: No Dangerous: No Regulated: No

General information This kit is compulsory for the erecting of rigid tanks and their connections (Oxfam type).

This kit works with all type of standard rigid water tanks (see code KWATTANKR)

Specifications Good quality tools, for short-term intensive use in rough condition.

Kit content list Code Description Qty ETOOKEYSFJ110 HANDLE, BRACE, for 3/8" square drive sockets 1 ETOOSOCK12P17J SOCKET 17 mm 3/8" 12 points 2 ETOOKEYSF40.17 SPANNER, COMBINATION, 17 mm ring, 15° angled, open and ring end 2 ETOOKEYSF40.24 SPANNER, COMBINATION, 24 mm ring, 15° angled, open and ring end 2 ETOOSCDRF6.5X20 SCREWDRIVER, flat head 6,5x200mm 2 ETOOFILEHRC200 FILE, HALF-ROUND, coarse, 200mm long 1 ETOOFILEN160 FILE, NEEDLE, knife cut, 160mm long 1 ETOOCUTTH HACKSAW, builder type, with 1 blade, L: 300mm 1 ETOOCUTTHB (hacksaw) BLADE, HSS, 10 teeth / cm, 300mm 3 ETOOCUTTL5 KNIFE/CUTTER, retractable, interchangeable blade, 150mm, alu. body 1 ETOOCUTTL5B (knife/cutter alu 150mm) BLADE, normal cut 5 ETOOKEYS200 PIPE WRENCH, strap nylon, max. 200 mm opening 2 ETOOMEASLS40 LEVEL aluminium 400 mm standard 1 ETOOMEASLL01 LEVEL, line level 1 ETOOMEASLP18 LINE PINS with 18m of line, PAIR 1 ETOOSCISSTD1 SCISSORS, std, 105mm, the pair 1 APROGLOVHDL10 GLOVES, protection, heavy duty leather, size 10 3 ETOOWRENV28O SPANNER, adjustable, max. 28mm opening 2 ETOOKEYSP2.5 WRENCH for PIPE open.65mm, lenght 18" 450mm with teeth 1 ETOOSAWSM150 HACKSAW, JUNIOR, for 150mm blades with 1 blade 1 ETOOSAWSM150B BLADE, for junior hacksaw, 150mm long, 10 teeth/cm 3 ETOOCUTTSF300 PLANE, SURFORM, 300mm 1 ETOOCUTTSF300B (surform 300mm) BLADE 2 ETOOKEYS6 PIPE WRENCH, adjustable grip head, max. 140 mm opening 1 WNECSTHO2-3 (coupling Storz) HOOK SPANNER, 2"-3" 4 ETOOLADD4500 LADDER, aluminium extandable, 4.5m 1 ETOOKEYSH6L KEY, hexagonal male, "Allen" 6mm, long shank 6 WTOOSPANSWIV SPANNER, ring type, for swivel fittings 1

Page 45: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

362 Water and Sanitation

Kit, adaptors, fittings for other systems, tanker truck Code Description Ind. price Ship. weight Ship. Vol. KWATFITT02 KIT, WATERTANK FITTINGS, other

systems/tanker truck ADAPTORS CHF 576 6kg 0.61x0.46x0.46

total vol. 0.13m3 Cold chain: No Dangerous: No Regulated: No

General information This kit allows connecting the Red Cross standard “Storz” system with other systems. It includes

BSP threaded couplings and Guillemin quick couplings.

Specifications See specifications in individual items data sheets.

Kit content list Code Description Qty WNECGACR3M2F COUPLING, GALVA, REDUCER, 3"-2", thread male/fem. 1

WNECGACR4F3F COUPLING, GALVA, REDUCER, 4"-3", threaded fem/fem 1

WNECGANN2M2M COUPLING, GALVA, NIPPLE, 2", threaded male/male 1

WNECGANN3M3M COUPLING, GALVA, NIPPLE, 3", threaded male/male 1

WNECGANN4M4M COUPLING, GALVA, NIPPLE, 4", threaded male/male 1

WNECGATT3FFF COUPLING, GALVA, TEE, 3", ND80, threaded fem/fem/fem 1

WNECGAUU2FF COUPLING, GALVA, SOCKET, 2", threaded fem/fem 1

WNECGAUU3FF COUPLING, GALVA, SOCKET, 3", threaded fem/fem 1

WNECGUIL2TM COUPLING, 'Guillemin', 2", threaded male 1

WNECGUIL3TM COUPLING, 'Guillemin', 3", threaded male 1

WNECGUILR32 COUPLING, 'Guillemin', REDUCER, 3"-2" 1

WNECSTCC2SM COUPLING, 'Storz', 2", threaded male 1

WNECSTCC3SM COUPLING, 'Storz', 3", threaded male 1

WNECSTCR3-2 COUPLING, 'Storz', REDUCER, 3"-2" 1

WNECSTHO2-3 (coupling Storz) HOOK SPANNER, 2"-3" 1

WTOOSEALTEFL SEALING TAPE, 'Teflon', for water connectors, roll 12mm x 12m 5

Page 46: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 363

Coupling “Storz”

Code Description Ref. WNECSTCC2SF COUPLING, STORZ, 2”, threaded female a WNECSTCC2SH COUPLING, STORZ, 2”, hose tail b WNECSTGA2 (coupling Storz) UNIVERSAL GASKET, 2" c WNECSTCC2SM COUPLING, STORZ, 2”, threaded male d WNECSTCP2 COUPLING, STORZ,PLUG, 2”, with chain e WNECSTCR3-2 COUPLING, STORZ, 3”-2”, reducer f WNECSTHO2-3 (coupling Storz), HOOK SPANNER, 2”-3” g Cold chain: No Dangerous: No Regulated: No

General information This type of water pipe coupling is the standard for the ICRC, the Federation and the WatSan ERU.

All items presented here in 2” are available in usual sizes of 1.½”, 2”, 3” and 4”. Codes and descriptions in the standard order list.

Be aware of the different types of gasket. Some are meant for suction or delivery only. Always use the universal type, which works for suction and delivery.

Beware of bad quality copies, with low quality moulding and machining. They usually break after a few uses.

Specifications Material: High tensile strength moulded aluminium alloy, machined with precision tools.

Options - Accessories WNEABACL015 BAND CLIP, high pressure, 15-20mm WNEABACL020 BAND CLIP, high pressure, 20-32mm WNEABACL025 BAND CLIP, high pressure, 25-40mm WNEABACL050 BAND CLIP, high pressure, 50-70mm WNEABACL077 BAND CLIP, high pressure, 77-95mm WNEABACL080 BAND CLIP, high pressure, 80-100mm WNEABACL087 BAND CLIP, high pressure, 87-112mm

Page 47: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

364 Water and Sanitation

Couplings galvanised

Code Description Ref. WNECGABB2M2F COUPLING,GALVA,BEND,2",threaded male/fem,large radius a WNECGACP3/4M COUPLING,GALVA,PLUG,3/4",threaded male b WNECGACR1M3/4F COUPLING,GALVA,REDUCER,1"-3/4",ND25/ND20,threa. male/fem c WNECGACR2F11/2F COUPLING,GALVA,REDUCER,2"-11/2",thr fem/fem d WNECGACR3M2M COUPLING,GALVA,REDUCER,3"-2",threaded male/male e WNECGAEE2M2F COUPLING,GALVA,ELBOW,2",90¬,thr.male/fem,sm. radius f WNECGANN11/2MM COUPLING,GALVA,NIPPLE,1"1/2,ND40,threaded male/male g WNECGATT2FFF COUPLING,GALVA,TEE,2",threaded fem x 3 h WNECGAUU001 GASKET FOR GALVA UNION COUPLING, 60-78 mm i WNECGAUU2M2F COUPLING, GALVA, UNION, in 3 pieces , 2", male/fem j WNECGAUU2FF COUPLING, 2", SOCKET threaded fem/fem, galva k WNECGATT11/4F4 COUPLING, GALVA, CROSS, 1.1/4", thread fem/fem/fem/fem l WNECBRCA1M1/2T COUPLING, BRASS, ADAPTOR, threaded male 1" to hose tail 1/2" m WNECGACA2M2T COUPLING, GALVA, ADAPTOR, thread male 2" to hose tail 2" n Cold chain: No Dangerous: No Regulated: No

General information This type of coupling is an international standard with BSP threads.

All items presented here are available in all usual sizes from ¼” to 6” and above.

Beware of bad quality couplings that may bring more problems than solutions.

Specifications Coupling made of galvanised forged steel. Should not present defects such as:

- Variation on the galvanisation. Cracks on the outside and the inside. Very thin section where shape presents corners or angles. Bad quality threads. Very thin material under the threaded part.

Page 48: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 365

Couplings, compression

Code Description Ref. WNECCOCC32CC COUPLING, COMPRESSION, SOCKET, hose diam. 32-32 a WNECCOCP32C COUPLING, COMPRESSION, PLUG, hose diam. 32 b WNECCOCR32C3/4M COUPLING, COMPRESSION, REDUCING,32x3/4" MALE, for MDPE hose c WNECCOCR32C1F NET, COUP,COMPR, REDUCING,32x1",fem.,for MDPE hose d WNECCOCR32C1M COUPLING, COMPRESSION, REDUCING, thr male 1" - hose diam32 e WNECCOEE25CC COUPLING, COMPRESSION, ELBOW,25x25 for MDPE hose f WNECCOER25C1/2F COUPLING, COMPRESSION, ELBOW,Reducing,25x1/2" fem, for MDPE hose g WNECCOTT90CCC COUPLING, COMPRESSION, TEE for HDPE hose ext.diam.90 h Cold chain: No Dangerous: No Regulated: No

General information This type of coupling is suitable for different types of plastic pipe. It is easy to fit and does not

require glue or heat.

All items presented here in 2” are available in usual sizes from ½”to 6” and above.

Specifications Compression coupling made of HDPE (high density polyethylene) with nylon rings and with O-ring.

Page 49: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

366 Water and Sanitation

Strainers

Code Description Ind. price Ship. weight Ship. Vol. WNEASTNR3 STRAINER + check valve, 3", thread

fem. CHF 60

WNEASTNR3+ STRAINER + check valve, 3", for hose, bronze

CHF 80

Cold chain: No Dangerous: No Regulated: No

General information Use of a strainer recommended to prevent solid material entering the pump.

Maximum passage of 5mm material recommended for our standard raw water pumps.

Should include a foot valve.

Cast brass body with stainless steel wire mesh makes an efficient strainer.

Available in all usual sizes. The 3” type is included in our standard 2” and 3” motor pump kits.

Specifications Strainer for raw water pumping. Cast brass with stainless steel wire mesh, with foot valve.

Page 50: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 367

Band clips

Code Description Ind. price Ship. weight Ship. Vol. WNEABACL015 BAND CLIP, high pressure, 15-20mm WNEABACL020 BAND CLIP, high pressure, 20-32mm CHF1.05 WNEABACL025 BAND CLIP, high pressure, 25-40mm CHF1.05 WNEABACL050 BAND CLIP, high pressure, 50-70mm WNEABACL077 BAND CLIP, high pressure, 77-95mm CHF1.61 WNEABACL080 BAND CLIP, high pressure, 80-100mm WNEABACL087 BAND CLIP, high pressure, 87-112mm Cold chain: No Dangerous: No Regulated: No

General information Band clips for water pipes fittings.

Many qualities are available. Check resistance to over tightening before purchasing.

For 3” and above, stronger band clips may be used. Type with plain steel band, tightening with bolt and nut system.

Steel band to be rounded on the edges to avoid cutting the hose.

Specifications Band clip of high tensile galvanised steel. Band clip of high tensile stainless steel.

Page 51: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

368 Water and Sanitation

Sealing, for water couplings

Code Description Ref. WTOOSEALHE HEMP, for plumbing, 500g a WTOOSEALHEP SEALING PASTE, PLUMBER, for hemp (tow) sealing, 100g b WTOOSEALTEFL SEALING TAPE, 'Teflon', for water connectors, roll 12mm x 12m c Cold chain: No Dangerous: No Regulated: No

General information Sealing materials for water pipes thread fittings.

Hemp with paste is better than PTFE (Teflon) tape for large size coupling.

Page 52: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 369

Hose, spiralled

Code Description Ind. price Ship. weight Ship. Vol. WNEHEPSP220 HOSE, EPDM, flexible spiralled,

suction/delivery, 2"x20m CHF 20

per meter

WNEHPVSP220 HOSE, PVC, flexible spiralled, suction/delivery, 2"x20m

CHF 7 per meter

Cold chain: No Dangerous: No Regulated: No

General information Hoses appropriate for both suction and delivery.

Many qualities are available. Check before purchasing.

EPDM (ethylene propylene diene) is stronger than PVC. Recommended for long term daily rough use.

PVC is cheaper and available in different quality. Above mentioned price is for standard quality.

All types available in usual sizes from 1” to 6”, by ½” increments, and above.

Other stronger type of hoses for intensive use or for specific liquids are available.

Specifications Standard PVC spiralled hose: Outer and inner tubes made of soft PVC, spiral made of hard PVC. Resistance to vacuum at 20°C: 70% for pipes from 25 to 100mm diameter. Service temperature: -10°C to 60°C Service pressure: 5bars Higher grade available in PVC: Resistance to vacuum at 20°C: 90% for pipes from 25 to 100mm diameter. Other material for stronger types: Tubes in EPDM, NR-SBR, NBR (all natural and synthetic rubbers). Spiral in stainless steel.

Page 53: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

370 Water and Sanitation

Hose, flat

Code Description Ind. price Ship. weight Ship. Vol. WNEHSBFL2 HOSE, SBR, FLAT for delivery, 2", per

meter CHF 6/m

WNEHSBFL215+C HOSE, SBR, FLAT for delivery, 2", + 2 "Storz", 15m

CHF 140

Cold chain: No Dangerous: No Regulated: No

General information Also available in 3” and 4”.

Many qualities are available. Check quality before purchasing.

Specifications Inner tube in black plain SBR (Styrene Butadiene Rubber) Reinforcing braid in polyester External coating in red acrylate Service pressure: 21bars Service temperature: -30°C to 70°C

Page 54: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 371

Pipe, PVC Code Description Ind. price Ship. weight Ship. Vol. WNEHPVRI3 HOSE, PVC, RIGID, push-in type, out.d.

63mm, NP9, L=4m CHF 6/m

WNEHPVRI4 HOSE, PVC, RIGID, push-in type, out.d. 110mm, NP9, L=4m

CHF 11/m

Cold chain: No Dangerous: No Regulated: No

General information Available standard sizes from 19mm to 200mm diameter. Other sizes can be found.

Many qualities are available. Check quality before purchasing.

Assembly methods:

- Push in system with rubber gasket from 63mm and above.

- Pipe to pipe or to PVC couplings: glue, connectors, threads

Specifications PVC pressure pipe NP10 (nominal pressure 10bars) with gasket rubber as per EN1452

Page 55: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

372 Water and Sanitation

Valves

Code Description Ref. WNEVBRBA1/2FFM VALVE, BRASS, BALL 1", threaded fem/male, 1/4 turn handle a WNEVPVBA2FF VALVE, PVC, BALL 2", fem x 2, gasket EPDM b WNEVSTBA2FF VALVE, STEEL, BALL 2", threaded fem x 2 c WNEVGGGA050,16 VALVE, CAST, GATE DIN3352-4A, DN050, PN16 d WNEVGGBU150,16 VALVE, CAST, BUTTERFLY wafer type, DN150, PN10/16, hand lev e WNEVSTTA3/4+E VALVE, AUTOMATIC, "Talbot" tap, thread. male 3/4" + elbow f WNEVBRFL3/4 VALVE, BRASS, FLOATING 3/4" g WNEVSSNR80,50 VALVE, NON RETURN, ND80, NP50, KSB MODEL2000 h WNEVBRBA1FM VALVE, BRASS, BALL 1/2", threa. fem/fem + nipple, 1/4 turn i Cold chain: No Dangerous: No Regulated: No

General information Main different types of valve.

Many qualities are available. Check quality before purchasing.

Assembling methods: glue, connectors, thread, male connection, female connection, etc, to be appropriate to the intended use.

Specifications Good quality valves in galvanised iron, brass, PVC, stainless steel, with good quality gasket and seals.

Page 56: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 373

Water distribution kit

Code Description Ind. price Ship. weight Ship. Vol. KDISNETW001 KIT, WATER DISTRIBUTION 15 parcels

3260kg 24.6m³

Cold chain: No Dangerous: No Regulated: No

General information This kit includes all the piping and fitting to link a storage tank to a distribution area located at

around 400m from the storage tank.

The number of pipes and fittings allows many more combinations.

The kit is constituted with several modules.

Kit content list Water pipe, 3”, uPVC, 8 bar, 4m long pieces: total 500m with couplings Distribution Fittings Kit, Ø 90 mm, uPVC/PE Water pipe, 90mm, OD PE, 7.5 bar, coil of 50m: total length 500m 10 uPVC compression couplings 1 lay flat suction hose LF3L, 3” 2 lay flat suction hose LF3S, 3” 5 suction hose SH3S Storz fitting and adaptors 3”to 2” BSP fitting and adaptors 3” to 2” Isolating, non-return strainer, 3” Float valve, 3” Fittings, 3”

Options - Accessories KWATFITT02 KIT, WATERTANK FITTINGS, other systems/tanker truck ADAPTORS KWATRAMP06S KIT, WATER TAP STAND, 6 self-closing taps KWATRAMP06T KIT, WATER TAP STAND, 6 taps 1/4 turn WNEHSBFL3-100 HOSE, SBR, FLAT for delivery, 3"x100m WNEHPVSP3-10 HOSE, PVC, flexible spiralled, suction/delivery, 3"x10m

Page 57: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

374 Water and Sanitation

Tap stand, water collection point

Code Description Ind. price Ship. weight Ship. Vol. KWATRAMP06S KIT, WATER TAP STAND, 6 self-

closing taps CHF 1’150 1 parcel

40kg 1.35x0.40x0.11m total vol. 0.6m³

KWATRAMP06T KIT, WATER TAP STAND, 6 taps 1/4 turn

CHF 712 1 parcel 54kg

1.25x0.42x0.26 total vol. 0.136m³

Cold chain: No Dangerous: No Regulated: No

General information Stand of 6 taps for water distribution to individuals in large number. The stand should be installed

in a safe area, where people can queue for water collection. The drainage of wasted water is essential to keep the area clean.

1 stand can serve1000 persons in 12 hours with 20lt each. The water pressure at the tap is determined by the head difference between the water tank base surface and the tap, it be may necessary to create an elevated ground surface to install the tank.

ICRC standard: Tap stand with six ¼ turn taps and 2” Storz coupling

- The ¼ turn taps are cheaper than the automatic valves, they close efficiently even with very low pressure.

- Supplied in one wooden box containing all necessary items to assemble a complete stand, and to terminate with a Storz 2” coupling.

Federation ERU standard: Tap stand with self-closing taps (also standard for Oxfam, MSF, …)

- The self-closing valves (Talflo, etc…) close “automatically”, saving water. Sometimes leakage may occur with very low pressure (less than 1 bar). More expensive than ¼ turn valves.

- Supplied in one box containing all necessary items to assemble a complete stand, and to terminate with a 1.1/4” BSP coupling.

See adaptation couplings in option list.

Specifications Material: Galvanized steel water pipes of 1.1/4” diameter, with couplings and clamps

Packaging: 1 wooden box, with 2 handles

Page 58: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 375

Kit content list KWATRAMP06T KIT, WATER TAP STAND, 6 taps 1/4 turn

Code Description Qty ETOOKEYSH8M ALLEN KEY, male hexagonal, 8mm 2

WNEAGACL11/4 CLAMP, to clamp 1.1/4" pipe, use with 8mm Allen key 4

WNECGABB11/4FF COUPLING, GALVA BEND, large radius,1.1/4", thread fem/fem 1

WNECGACR11/4F1F COUPLING, GALVA, REDU, socket, 1.1/4"-1", thread fem/fem 1

WNECGACR11/4F1M COUPLING, GALVA, REDU, socket, 1.1/4"-1", thread fem/male 1

WNECGACR11/4F3/4F COUPLING, GALVA REDUCER, socket, 1.1/4"-3/4", thread fem/fem 2

WNECGACR11/4M3/4F COUPLING, GALVA REDUCER, bush, 1.1/4"-3/4", thread male/fem 4

WNECGATT11/4F4 COUPLING, GALVA CROSS, 1.1/4", thread fem/fem/fem/fem 2

WNECGATT11/4FFF COUPLING, GALVA TEE, 1.1/4", thread fem/fem/fem 1

WNECGATT2FF11/4F COUPLING, GALVA TEE, reduced, 2"-1.1/4", thread fem/fem/fem 1

WNECGAUU1.1/4FF COUPLING, GALVA SOCKET, 1.1/4", threaded fem/fem 2

WNECGAUU1.1/4FF3 COUPLING, GALVA UNION, 1.1/4", 3 pieces, threaded fem/fem 1

WNECSTCC2SM COUPLING, half symetrical, 'Storz', 2", threaded male 2

WNECSTCP2 COUPLING, half symmetrical 'Storz', 2", plug with chain 1

WNECSTGA2 (coupling half sym. Storz) GASKET, 2" 2

WNEVBRBA3/4FS VALVE, BALL, ¾”, brass, 1/4 turn, thread fem/angled sprout 9

WWATRAMPF100 PIPE, STAND, galva, 1.1/4", 1.00m 4

WWATRAMPSP10 HOLDER, SPACER, for distribution stand feet, 10mm Re-bar 2

WWATRAMPT030 PIPE, STAND, galva, 1.1/4", 0.30m, threaded both ends 1

WWATRAMPT050 PIPE, STAND, galva, 1.1/4", 0.50m, threaded both ends 1

WWATRAMPT060 PIPE, STAND, galva, 1.1/4", 0.60m, threaded both ends 2

WWATRAMPT065 PIPE, STAND, galva, 1.1/4", 0.65m, threaded both ends 2

WWATRAMPT070 PIPE, STAND, galva, 1.1/4", 0.70m, threaded both ends 1

WWATRAMPT090 PIPE, STAND, galva, 1.1/4", 0.90m, threaded both ends 1

Options - Accessories COUPLING, GALVA, NIPPLE, 1.1/4", thread. male/male COUPLING, compression hose d.ext 32 / thread. male 1.1/4" COUPLING, compression hose d.ext 32 / thread. male 1" COUPLING, GALVA, REDU, 1.1/4"-1", thread. male/fem

Page 59: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

376 Water and Sanitation

Diatomite earth

Code Description Ind. price Ship. weight Ship. Vol. WWTECONS001 DIATOMITE EARTH, bag of 20kg CHF 1.5/kg Bag 20kg 0.07m³/bag Cold chain: No Dangerous: No Regulated: No

General information Diatomite earth for water filtration. Must be used with the appropriate equipment.

Used in the filtration unit GBI3000.

The diatomite earth mixed with water forms a coating on the filter element. This coating is the filtration agent.

Several types are available with different filtration specifications.

Specifications Diatomite earth. For example: Type Celatom LW12 from United Minerals Pallet of 39 bags, 780kg, 2.56m3

Options - Accessories WWTUGBI3000 WATER PURIFICATION UNIT, GBI 3000-D (3000 G/h - Diesel)

Page 60: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 377

Aluminium sulfate Code Description Ind. price Ship. weight Ship. Vol. DCHPALUSG50 ALUM. SULFATE, granules,

50 kg bag CHF 21

Per bag 50kg Bag of 50kg 20MT in 1 TC20’

Cold chain: No Dangerous: No Regulated: No

General information Sedimentation agent for turbid water.

- Creates flocs of a higher density by agglomerating fine particles in suspension in water.

Product available in several forms: Powder, granules, stones.

- We always recommend the granulates.

This is a low cost natural product available in many places, often used in large quantities. Local purchase recommended.

Specifications Aluminium sulfate, 17-18% Al2O3 technical iron free, in granules, in PP (polypropylene) 50kg bags.

Page 61: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

378 Water and Sanitation

Water purification agent

Code Description Ind. price Ship. weight Ship. Vol. DCHPCHLF01 FLOCUL. + DISINF. 'CHLOR-FLOC',

fr wat. tr., 1 kg for 5000 l CHF 12 14kg per box

of 12 tin of 1kg 0.345x0.25x0.26m

vol.: 0.023m³ DCHPCHLF02T FLOCUL. + DISINF. 'CHLOR-FLOC',

for 1L water tr., tab.

Cold chain: No Dangerous: No Regulated: No

General information Sedimentation and disinfection agent for raw water.

WaterMaker ‘Chlor-Floc’ powder contains coagulants, flocculent aids and absorbents and effectively removes suspended solids and colouring from water. It also contains disinfectant

Specifications Chlor-Floc WaterMaker

Page 62: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 379

Chlorine, NaDCC

Code Description Ind. price Ship. weight Ship. Vol. DASDCHLA0005T CHLORE, 5 mg (NaDCC 8.5 mg), for

1L water purif., tab. CHF 0.0088

per tablet Box of 50’000

in strips of 10 tab

DASDCHLA0020T CHLORE, 20 mg (NaDCC 33 mg), for 5L water purif., tab.

CHF 0.010 per tablet

Box of 50’000 in strips of 10 tab

DASDCHLA0040T CHLORE, 40 mg (NaDCC 67 mg), for 10L water purif., tab.

CHF 0.012 per tablet

Box of 16’000 in strips of 10 tab

DASDCHLA0100T CHLORE, 100 mg (NaDCC 167 mg), for 20L water purif., tab.

CHF 0.015 per tablet

Box of 14’000 in strips of 10 tab

DASDCHLA1000T CHLORE, 1000 mg (NaDCC 1670 mg), multipurpose, tab.

CHF 0.067 per tablet

Box of 200 tab

DASDCHLA5000T CHLORE, 5000 mg (NaDCC 8680 mg), fr 1000L wat. purif., tab.

CHF 0.26 per tablet

Box of 60 tab

Cold chain: No Dangerous: No Regulated: No

General information

Indications Disinfection of infected wounds.

Disinfection of instruments, objects, equipment, linen.

Disinfection of floors and surfaces.

Water disinfection.

Beware! Not all formulations are convenient for use on wounds and for drinking water disinfection.

Storage Store in dry and well ventilated places. Be sure containers are well sealed after use.

Presentation Effervescent tablet containing the indicated amount of sodium dichloroisocyanurate (or NaDCC, or sodium troclosene, or sodium dichloro-s-triazinetrione) which releases the indicated amount of chlorine when dissolved in water. Strength of solutions are generally not expressed in NaDCC concentration but in content of available chlorine; expressed either in percentage in parts per million (ppm) or in g or mg per litre (1ppm = 1mg/litre = 0.0001%). One tablet containing 1.67g NaDCC releases 1g available chlorine when it is dissolved in water. 1g available chlorine per litre = 1g/litre or 0.1% or 1000ppm available chlorine.

Page 63: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

380 Water and Sanitation

Unlike Calcium hypochlorite which is corrosive (pH of solution is 14 to 16) and needs the addition of Sodium Bicarbonate to decrease its alkalinity, NaDCC solution may be used on wounds because its pH is 6 to 7.

Use Disinfection of wounds: 1 tablet of 1g per litre = 1000ppm or 0.1% available chlorine. Instruments disinfection: 1 tablet of 1g per litre = 1000ppm or 0.1% available chlorine. General disinfection: Clean conditions: 1 tablet of 1g per litre = 1000ppm or 0.1% available chlorine. i.e. clean surfaces, clean white linen, clean equipment. “Medium clean” conditions: 2 tablets of 1g per litre = 2000ppm or 0.2% available chlorine. i.e. floors, sinks. “Dirty” conditions: 5 tablets of 1g per litre = 5000ppm or 0.5% available chlorine. i.e. equipment soiled with blood, sputum…, laboratory equipment… Wait minimum 15 minutes before rinsing. Blood spillage: 10 tablets of 1g per litre = 10 000ppm or 1% available chlorine. Drinking water disinfection: 1 tablet of 1g per 200litres clear water = 5mg/l = 5ppm available chlorine. 1 tablet of 5mg per 1litre clear water = 5mg/l = 5ppm available chlorine. Allow contact for 30 minutes minimum before drinking. To treat smaller quantities: use the tablets of 5mg (1 tablet per litre). For large scale water treatment, the use of calcium hypochlorite is recommended, unless transport constraints and prices are prohibitive.

Precautions Do not swallow the tablets. Avoid inhalating vapour and dust during handling. Do not expose the product to flame. Do not incinerate. As a precaution, do not mix with detergents. Toxic chlorine gas can be released with some types of detergent. Only anionic detergents (i.e. soft soap) can safely be mixed with NaDCC solutions. Do not mix with acid solutions (i.e. urine). This causes a release of toxic chlorine gas. Prepare solutions with clean water in non metallic containers, just before use.

Toxicology information Signs, symptoms, and effects of exposure: EYE: Exposure may cause severe irritation and/or chemical burns with corneal damage. Impairment of vision is possible. SKIN: Accurate exposure can cause severe irritation and/or chemical burns Chronic exposure effects would be similar to those from accurate exposure except for effects secondary to tissue destruction. Prolonged skin exposure may cause dermis destruction with impaired skin regeneration at the site of contact. INGESTION: Ingestion can cause irritation and/or chemical burns to the gastrointestinal tracts characterized by nausea, vomiting, diarrhoea, abdominal pain, bleeding and ulceration. Chronic toxicity via this route is unlikely due to its corrosive nature INHALATION: Acute exposure may cause severe irritation to respiratory tract resulting in lung oedema which can cause shortness of breath, wheezing, choking, chest pain and impaired lung function. Inhalation of high concentrations can result in permanent lung damage Chronic exposure may cause impairment of lung function and permanent lung damage.

Page 64: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 381

First Aid Measures EYES: Immediately flush with large amounts of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Call immediately a physician. SKIN: Immediately flush with water for at least 15 minutes. Call a physician. If clothing comes in contact with the product, the clothing should be removed immediately and should be laundered before re-use. INGESTION: Immediately drink large quantities of water. DO NOT induce vomiting. Call immediately a physician. DO NOT give anything by mouth if the person is unconscious or is having convulsions. INHALATION: Remove victim to fresh air. Support respiration if needed. Call a physician.

Options - Accessories WMEAPOOL10 POOL TESTER + accessories

Page 65: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

382 Water and Sanitation

Chlorine, HTH Code Description Ind. price Ship. weight Ship. Vol. DASDCHLA7G5 CHLORE (HTH), 60 to 70%, granulates,

5 kg box, IATA CHF 41.00 6kg 0.01m³

DASDCHLA7G25 CHLORE (HTH), 60 to 70%, granulates, 25 kg box, IATA

CHF 150.00 27kg 0.027m³

DASDCHLA7G45 CHLORE (HTH), 60 to 70%, granulates, 45 kg drum

CHF 170.00 48kg 0.054m³

Cold chain: No Dangerous: Yes Regulated: Yes IATA packing

General information

Indications Disinfection of surgical instruments and linen.

Disinfection of floors and surfaces.

Water disinfection.

Presentation Calcium hypochlorite (“HTH” High Test Hypochlorite) grains, ± 70% available chlorine. The form Granulates is recommended instead of the powder form which is extremely dangerous to manipulate (highly volatile). 1 plastic measure (15g). IATA container, labelling and packaging of 10 individual tins of 0.5kg in 1 box of total weight 5kg net (according to UN n°2880 for air transport regulation –cargo and mixed cargo/passengers-). There are also 25kg drums for air transport in cargo airplanes, and 45kg drums that could be used for road (ADR6,61b) and sea (IMC08) shipments only. Sea transport by refrigerated containers only. The UN2880 correspond to wet HTH with the below specifications of 5.5 to 10% moisture. The dry type of HTH corresponds to UN1748 number with packaging identical to UN 2880. The chlorine content should be labelled on the product’s packaging and expressed in % of available chlorine. The chlorine content of diluted solution is expressed: either in % of available chlorine, or in parts per million (ppm) of available chlorine, or in mg/litre of available chlorine. 0.0001% of available chlorine = 1ppm = 1mg/litre. The available (free) chlorine can be measured with a pool tester.

Use For clean conditions (e.g. instruments and linen): 0.1% (1000ppm) available chlorine. For floors, equipment and furniture in reasonably clean conditions: 0.2% (2000ppm) available chlorine. For floors and equipment in dirty conditions: 0.5% (5000ppm) available chlorine. For chlorinating drinking water a stock solution of 1% available chlorine is used. The 1% available chlorine stock solution should be kept in an airtight, opaque, non metallic container, away from light and heat and should be replaced every 1 to 2 weeks. (For chlorinating technics, see Guide “Public health engineering in emergency situation”, MSF).

Page 66: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 383

Precautions Handle the dry product with care (avoid jolts and exposure to high temperatures or flames). Avoid inhaling vapours and dust when opening or handling the containers. Always dilute in non-metal containers just before use. Prepare solution with clean water. Do not mix with detergents. Do not bring the dry product in contact with organic materials (e.g.: corpses): risks of explosion or spontaneous flames.

Handling and Storage Ventilation: Use local exhaust ventilation to minimize dust level and chlorine gas Respiratory protection: Chlorine cartridge gull face piece respirator with dust/mist pre-filter Personal protection: Neoprene or PVC glove, boots and apron/suit Keep containers tightly sealed. Store in a clean dry well ventilated area. Production of gases will anyway damage all carton boxes present in the same room, thus it is recommended to store HTH on its own in a separate area from general stock. After a while it will also damage its own carton packaging, thus long storage (more than 6 month) is not recommended for containers in carton boxes. Keep away from sources of heat where temperatures in excess of 52°C for a period of 24 hours or more will be encountered. Keep separated from powdered metals, ammonium compounds cyanides and hydrogen peroxide. Keep away from moisture, never use a wet scoop to take some HTH from a drum. This may end up in an explosion followed by fire. Reacts with acids, evolving chlorine, an irritating corrosive and toxic gas. May cause fire in contact with combustible material. Corrosive to most metal in the presence of moisture.

Toxicology information Signs, symptoms, and effects of exposure: EYE: Exposure may cause severe irritation and/or chemical burns with corneal damage. Impairment of vision is possible. SKIN: Accurate exposure can cause severe irritation and/or chemical burns Chronic exposure effects would be similar to those from accurate exposure except for secondary effects to tissue destruction. Prolonged skin exposure may cause dermis destruction with impaired skin regeneration at the site of contact. INGESTION: Ingestion can cause irritation and/or chemical burns to the gastrointestinal tracts characterized by nausea, vomiting, diarrhoea, abdominal pain, bleeding and ulceration. Chronic toxicity via this route is unlikely due to its corrosive nature. INHALATION: Acute exposure may cause severe irritation to respiratory tract resulting in lung oedema which can cause shortness of breath, wheezing, choking, chest pain and impaired lung function. Inhalation of high concentrations can result in permanent lung damage Chronic exposure may cause impairment of lung function and permanent lung damage.

First Aid Measures EYES: Immediately flush with large amounts of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Call immediately a physician. SKIN: Immediately flush with water for at least 15 minutes. Call a physician. If clothing comes in contact with the product, the clothing should be removed immediately and should be laundered before re-use.

Page 67: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

384 Water and Sanitation

INGESTION: Immediately drink large quantities of water. DO NOT induce vomiting. Call immediately a physician. DO NOT give anything by mouth if the person is unconscious or if having convulsions. INHALATION: Remove victim to fresh air. Support respiration if needed. Call a physician.

Fire-Fighting measures Cool exposed containers with water. Do not use dry extinguishers containing ammonium compounds.

Remarks The taste of chlorine in water is not a proof of residual chlorine. For equipment disinfection, Sodium dichloroisocyanurate (NaDCC) should be preferred as they are less corrosive. See MSF “Essential Drugs” and HCR/MSF “Guide for the use of disinfectants”. Can often be purchased locally, see local water responsible, hotel swimming pool, etc. The local purchase if possible is highly recommended because transport constraints considerably increase the price of HTH. Do not confuse with chlorinated lime which only contains 30% available chlorine and is less stable. Storage: Store in air-tight containers: protected from light, heat and humidity. Good preservation (2% average available chlorine loss per year).

Specifications Product Calcium hypochlorite in granular form, highly soluble in water Granular size: More than 90% retained on 150micron standard sieve More than 85% passing through 1.4mm standard sieve. Available chlorine: 68 % Stability: 10 % of loss of chlorine of the initial available chlorine. Moisture content: 5,5 to 10 %

Packing and marking To be packed in approved containers according to: IATA Calcium hypochlorite mixtures, Wet, UN 2880 PG II, ERG N° 45 IMDG Calcium hypochlorite mixtures, Wet, Cl. 5.1. UN 2880

IMDGM Page 5138; EmS N° 5.1-06

Options - Accessories WMEAPOOL10 POOL TESTER + accessories

Page 68: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 385

Water purification unit, GBI 3000

Code Description Ind. price Ship. weight Ship. Vol. WWTUGBI3000 WATER PURIFICATION UNIT, GBI

3000-D (3000 G/h - Diesel) n/a 327kg 1.87x0.92x1.11m

Total vol.1.90m³ Cold chain: No Dangerous: Yes - Chlorine Regulated: Yes - IATA pack chlorine

General information System capable of producing safe drinking water from biologically contaminated fresh water

sources such as lakes, streams, ponds and wells.

Performance 5,000 to 10,000 l/h depending on raw water quality. Maximum capacity: 11,365 l/h.

Proportional post-chlorination. Adjustable feed rates from 0 to 7.9 PPM, based on 1% chlorine solution.

Self contained. Modular construction allows moving each module easily by hand. Field portable, trailer option available. Fitted for airlift. Fast set-up in 30 minutes or less. Can be put in a Land Cruiser PU or SW.

Very high flexibility allows following moving population, and fast set up water production.

ICRC standard. Several units are available from stock for acute emergency situation. They are then reconditioned and put back in stock.

Specifications Farymann engine OHV diesel, 4 stroke, 1 cylinder. Direct fuel injection. Hand Start Air cooled. Variable speed control. Exhaust silencer. Oil and fuel filters. Output approx 4.3 kW at 3600 rpm. Consumption 1.5 l/h 2” Centrifugal Self-priming pump in all bronze & stainless steel construction 530 lt/min with shut-off head 28m Turbine driven slurry mixing with automatic precoating of diatomite earth filter Welded aluminum channel main frame. Replaceable “A” skid supports Tubular aluminum protective cage. Aluminum modular frames. Powder coated/polyurethane finish

Page 69: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

386 Water and Sanitation

Kit content list Stainless steel fasteners Start-up supplies include 22.7kg diatomite earth and 2.3kg granular chlorine Suction (with strainer) and discharge hoses with STORZ couplings Waste & sampling hoses Equipment covers Tool Box Lifting handles, rings & sling Red Cross /Crescent logo painted in red on white background.

Options - Accessories Custom fitted trailer 180 day operating spares kit High turbidity feed system 30,60 or 90 day consumables

Page 70: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 387

Water purifier unit, 5.4m3 at 75NTU, transportable

Code Description Ind. price Ship. weight Ship. Vol. KWATTREAUNITTW6

Water purifier unit, 5.4m3 at 75NTU, transportable

CHF 23652 3000kg 2 parcels of each 2x2x4m

Total vol.32m³ Cold chain: No Dangerous: Yes Regulated: Yes IATA packing

General information General Drinking water purifier operating according to the precoat filtration principle

- Uses pre-chlorination.

- Flocculation & coagulation with ferric chloride.

- Adsorption with powdered activated carbon.

- Filtration using candle filters. Candle filters (replaceable) pretreated with diatomite and activated carbon.

Performance TWA 6: Flow rate of 5.4 m³/h at 75NTU

TWA 10: Flow rate of 10 m³/h at … NTU

Unit is not able to desalinate brackish or sea water.

Can reduce max. turbidity of 500 NTU to 5 NTU. Disinfection to WHO recommended levels.

Included in ERU, Water and Sanitation, Specialised Wat-San (e.g. Austrian, German Red Cross)

Specifications Drinking Water Purifier Sterling-Berkefeld, Germany TWA6 or TWA10

Kit content list Raw water suction (with suction filter) & delivery hoses Process water manifold with valves & connecting hoses Filtered water connecting hoses Storage Tanks 4 x Raw Water & 2 x Treated Water Filtered water / precoating pump suction induction manifold with valves

Page 71: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

388 Water and Sanitation

2 x candle filter pressure housings with valving for backwashing Chlorine dosing unit Distribution tapstand with 5 taps Mixing buckets Red Cross /Crescent logo painted in red on white background. TWA 6: 8 m 3 Pretreatment tanks with floating suction Uses 1 Raw Water Feed PumpSets TWA 10: 12 m 3 Pretreatment tanks with floating suction Uses 3 Raw Water Feed PumpSets

Options - Accessories Set of consumables for 90 days

Page 72: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 389

Water purifier unit, 3m3/hour at 20NTU, transportable

Code Description Ind. price Ship. weight Ship. Vol. KWATTREASETA Water purifier unit, 3m3/h at 20NTU,

transportable

Cold chain: No Dangerous: Yes - chemicals Regulated: Yes IATA packing

General information Transportable water purifier unit type SETA2E3000, 3m³/hour.

Included in ERU, Water and Sanitation, Specialised Wat-San (e.g. Spanish Red Cross)

Objective of the plant The unit is designed to give 3000 litres/hour of physical and bacteriologically drinking water, the entrance water will be free of contamination of industrial type (hydrocarbons, chemical waste, etc), according to classification A2-A3 of the WHO. and with a turbidity for good operation not superior to 20 N.T.U. The destination is the one of supplying of capable drinking water for human consumption to rural nucleus isolated in emergency situation and with capacity of being transported by 4x4 vehicles and trailer, including a autonomous generator plan. Foreseen treatment The gross water is sucked from the taking point (lake, river eddy, canal, etc) by means of submersible pump together to flexible hose to the tow. Aluminium sulfate is injected at the intake of the gross water, with crushed hypochlorite that carries out a double function; first to facilitate solids sedimentation in the bottom of the settler and second to guarantee the destruction of the present germs. A basket filter of 2 mm then retains the solids that pass through the filter of the submersible pump. The contact settler-chamber allows for its volume, to have a time of residence or contact of one hour, favouring the clarification of the gross water as well as its first disinfection. Being sedimented in the bottom, the solids are removed periodically. Clarified water passes to the last chamber where it gets sucked by a pumping set. The water passes then to a SILEX FILTER to eliminate the residual solids. Finally to ACTIVE COAL FILTER whose function is to eliminate the odours and present flavours in the water as well as the residual chlorine not consumed in the oxidation of the organic matter carried out in the chlorination. The treated water is send to 10.000L tank, getting a last hypochlorite injection that allows the storage without bacterial, but enough proliferation to be fit for human consumption.

Page 73: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

390 Water and Sanitation

Floating container for slow dissolving chlorine

Code Description Ind. price Ship. weight Ship. Vol. KWATDOSI02 KIT, TREATMENT DOSER, slow

dissolve chlorine floating cont. CHF 25

Cold chain: No Dangerous: Yes - Chlorine Regulated: Yes – IATA packaging

General information Floating container to hold slow dissolving chlorine tablets into a water tank for disinfection.

Must be used with the appropriate “slow dissolve” tablets.

Adjustable with rotating opening control system.

Options - Accessories DASDCHLA7T2 CHLORE (HTH), 60 to 70%, 5 x 200 g tab., slow dissolve

Page 74: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 391

Kit, water treatment, suction side doser

Code Description Ind. price Ship. weight Ship. Vol. KWATDOSI01 KIT, WATER TREATMENT, suction

side doser CHF 2365 1 parcel

105kg 0.75x0.61x1.11m Total vol.0.51m³

Cold chain: No Dangerous: Yes. Chemicals Regulated: Yes. IATA packing

General information Suction side dosing of water treatment compounds.

Equally suitable for coagulants, flocculants & disinfection mixes.

Used in conjunction with raw water pumping in to Onion or rigid corrugated tanks.

Rapid thorough mixing of induced flow through pump impeller.

Doser Galvanized Malleable Iron fittings.

Specifications Suction side dosing of water treatment compounds. Conditions of Service Line Flow Rates up to 140 m³/hr Dosing Rates up to 150 litres/hour Equally suitable for coagulants, flocculants & disinfection mixes.

Kit content list MDPE (medium density Polyethylene) tank and lid. Other elements in brass and plastic. Internal filter Dosing solution on/off valve. Adjustable induction flow rate. Flow throttling valve. General Complete set of operator manuals in English and/or French. 210 litre nominal product tank size with lid. Adaptors allow either 2,3 or 4 inch suction lines to be accommodated. Compatible with all standard 2,3 &4 inch WatSan Type Pumping Kits. 2 ”,3 ” and 4 ” Storz couplings. 25 kg sack of aluminium sulphate. Suitable for dosing of other solutions.

Page 75: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

392 Water and Sanitation

Mixing Paddle All items packed in a sturdy plywood case. Red Cross /Crescent logo painted in red on white background. Options Electric mixing paddle. Full range of hoses, couplings/quick couplings, strainers, etc. Coagulation & Disinfection Equipment Manual in grip seal waterproof bag.

Page 76: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 393

Kit, water treatment, Sanikit

Code Description Ind. price Ship. weight Ship. Vol. KWATDOSI03 KIT, TREATMENT DOSER, SANIKIT

for HTH purification tab. CHF 2’420

Cold chain: No Dangerous: Yes. Chemicals Regulated: Yes. IATA packing

General information Complete water disinfection system using chlorine tablets.

Suitable for small villages, hospitals, etc.

With a gravity fed or pressurized water supply about ¼ of the water to be treated flows through a mixing chamber dissolving chlorine tablets. A concentrated chlorine solution is created and then remixed with the remaining ¾ of water. This freshly treated water needs to flow into a storage tank to insure proper contact time.

Works with 140gr chlorine tablets at 68% available chlorine (see accessories).

Specifications Sanikit.

Power free, automatic dosing proportional to flow, intermittent or continuous flow, quick and easy installation and operation.

UV rated structure, rotomolded PEHD (high density polyethylene) body, reinforced PVC piping.

Options - Accessories DASDCHLA7T1 CHLORE (HTH), 60 to 70%, 140 g tab., 11.3 kg drum

Page 77: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 395

Kit, treatment unit, filter tank kit

Code Description Ind. price Ship. weight Ship. Vol. KWATWTUFILT01 KIT, TREATMENT, UNIT, Roughing

filter tank Kit 2 parcels

640kg 2 parcels

Total vol.2.55m³ Includes : KWATTANKR10 KIT, WATERTANK, steel sheet + PVC

liner, 10 m3, rigid 310kg 1.65x0.95x0.65m

Total vol.1.02m³

Roughing Filter Kit for T11 330kg 1.49x1.22x0.84m Total vol.1.53m³

Code Description Ind. price Ship. weight Ship. Vol. KWATWTUFILT02 KIT, TREATMENT, UNIT, Slow sand

filter tank Kit 6 parcels

1987kg 6 parcels

Total vol.8.7m³ Includes : KWATTANKR70 KIT, WATERTANK, steel sheet + PVC

liner, 70 m3, rigid, no roof 2 parcels

402kg 284kg Total 686kg

2.9x0.8x0.58m 1.33x0.92x0.86m

Total vol.2.4 m³ KWATTANKR95 KIT, WATERTANK, steel sheet + PVC

liner, 95 m3, rigid 3 parcels

480kg 321kg 100kg

Total 901kg

2.9x0.9x0.6m 1.33x0.92x0.86m 1.36x0.64x0.48m Total vol.3.04m³

Filtration Fittings Kit 1 parcel 400kg

2.35x1.25x1.10m Total vol.3.24m³

Filtration Tool Kit Included above Included above Cold chain: No Dangerous: Yes Regulated: Yes - IATA packed chlorine

General information Typical Filtration Layout: see drawing.

Minimum of 2 roughing filter packs are needed for each water filtration pack system.

Add the required number of Red Cross Tapstands from 22.2 Slow Sand Filter.

In this configuration, the T70 tank is supplied without roof.

Page 78: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

396 Water and Sanitation

Kit content list Roughing Filter Pack comprising : 1 x 11,000 litre Tank Steel Kit complete 1 x Roughing Filter Kit for T11 Water Filtration Pack (Slow Sand Filters) comprising : 1 x 95,000 litre Tank Steel Kit complete with Tank Liner and Tank Roof 1 x 70,000 litre Tank Steel Kit with Tank Liner without roof 1 x Filtration Fittings Kit

1 x Filtration Tool Kit

Page 79: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 397

Kit, water testing, portable microbiological laboratory

Code Description Ind. price Ship. weight Ship. Vol. KWATWLAB01 KIT, LABO. BACTERIO. ANALYSIS +

consummables for 200 tests CHF 3‘500

KWATWLAB02 KIT, WATER TESTING, Alum, DelAgua, Chlorine & Ph, Turbidity

CHF 3‘500 10kg 0.37x0.14x0.26m

Cold chain: No Dangerous: No Regulated: No

General information Water Quality Tester Packs comprising incubator and testing equipment able to perform: Fecal

coliform bacteria count, Residual free and total Chlorine tests, pH tests, Turbidity test, Electrical Conductivity and Temperature tests.

- The Sandberg kit comes with a set of consumables to perform 200 tests.

- The Delagua kit comes with a set of consumables to perform 200 tests.

Consumables can be ordered separately as a set of renewable supplies. See options.

The Sandberg kit is contained into an active cool box that works on car cigarette lighter. It does not require sterilizer. The nutrient pads have a shelve life of 12 months at room temperature, do not need cold chain.

The battery included in the Delagua kit should be charged every 2 weeks when stored. Charger is also included in the kit.

The Sandberg kit uses the car battery or the mains as power source.

Specifications Delagua Testing Kit Sandberg Trawas Portable laboratory kit

Options - Accessories WMEAPOOL10A (pool test) TABLET DPD1 for dosing free chlorine WMEAPOOL10B (pool test) TABLET DPD3 for dosing total chlorine WMEAPOOL10C (pool test) TABLET RED PHENOL for PH control No code (Delagua testing kit) RENEWABLE SUPPLIES No code (Delagua testing kit) BATTERY, 12V, non spillable

Page 80: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

398 Water and Sanitation

Water testing, Aluminium

Code Description Ind. price Ship. weight Ship. Vol. WWATWLABAT1 WATER TEST, aluminium CHF55.00 WWATWLABAT1T (aluminium water test) TABLETS for

dosing aluminium CHF0.60

per test

Cold chain: No Dangerous: No Regulated: No

General information Alum Tester Pack comprising: Pocket type Aluminium test kit (range 0 -0.5 mg/l), 20 tests.

Specifications

Alum testers are available in many places, check quality before purchase. Check also expiry dates of consumables.

Page 81: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 399

Turbidity measuring tube, 5 to 2000NTU, plastic

Code Description Ind. price Ship. weight Ship. Vol. WMEATURB10 TURBIDITY MEASURING TUBE, 5 to

2000NTU, plastic CHF35.00

Cold chain: No Dangerous: No Regulated: No

General information Turbidity tube for measuring water turbity.

Specifications Turbidity Tester Pack comprising: 2 x 30cm plastic tube (push fit) calibrated 5 -2000 NTU

Page 82: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

400 Water and Sanitation

Pool testor

Code Description Ind. price Ship. weight Ship. Vol. WMEAPOOL10 POOL TESTER + accessories CHF20.00 WMEAPOOL10A (pool test) TABLET DPD1 for dosing

free chlorine

WMEAPOOL10B (pool test) TABLET DPD3 for dosing total chlorine

WMEAPOOL10C (pool test) TABLET RED PHENOL for PH control

Cold chain: No Dangerous: No Regulated: No

General information Chlorine & pH Tester Pack (Pool tester) comprising: Pocket type Chlorine (range 0.1 -6.0mg/l) & pH (range 6.8 -8.2) test kit, for 20 tests.

Specifications Pool tester are available in many places, check quality before purchase. Check also expiry dates of consumables.

Page 83: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 401

Sanplat, squatting plate moulding set

Code Description Ind. price Ship. weight Ship. Vol. WSANSQPL002 MOULD, for making latrine slabs,

SanPlat type CHF1’275

Cold chain: No Dangerous: No Regulated: No

General information A SanPlat is a sanitation platform which is an improved latrine slab (but not necessarily a structural

slab).

SanPlats are designed with smooth surfaces to make simple latrines hygienic. They are made in fine concrete, a material which is long lasting and easy to keep clean. The concrete is formed using moulds which give correct dimensions and distinct shapes. Both the smooth concrete surfaces and the distinctive shape appeal to the eye. SanPlats have been found to be an effective incentive latrine building campaigns.

They have the following principal features which improve hygiene and safety:

- Elevated foot-rests with a defined position and shape, which help the user to find the right position even at night.

- A well-studied design has essentially reduced the fouling of the squatting areas, especially in public and institutional latrines, as the people now know where to place their feet.

- Drop-hole shaped like a keyhole, which is safe even for a very small child.

- It is big enough to use comfortably and small enough to be completely safe.

- A tight-fitting lid; tight enough to shut out the foul smell, thereby also making the toilet room pleasantly odourless and free from flies.

For public places and institutions, latrines should be fitted with ventpipes for smell and fly reduction and not have lids as the handle of the lid may cause hand-to-hand contamination.

The SanPlat is easy to clean with water and a brush.

The SanPlat is relatively easy to transport and easy to install, requiring no special skill.

The SanPlat latrine is an improved traditional latrine. It costs less than a ventilated improved pit (VIP) latrine. The biggest advantage apart from cost is the simplicity and the possibilities it gives in scale.

Page 84: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

402 Water and Sanitation

Squatting plate, polypropylene, + drop-hole cover

Code Description Ind. price Ship. weight Ship. Vol. WSANSQPL001 SQUATTING PLATES, polypropylene

+ drop-hole cover CHF 18.00

per unit 4kg per unit

=240kg for 60 units

60 units per pallet 1.2x0.8x1.5m

Total vol.1.45m³ Cold chain: No Dangerous: No Regulated: No

General information Manufactured in vermin and termite proof polypropylene. Lightweight and strong with rigid,

smooth surface for easy cleaning. Feet placement areas designed to prevent slipping.

Can be used on shallow or deep trench up to 600mm wide with additional support and bearing onto the ground provided by poles or timbers at least 1200mm long.

- The squatting plates should be attached to the timbers or poles using the cable binders. There are slots provided along the edges of the squatting plate. It may be necessary to provide for further fixing in front of & behind each footplate.

The squatting plates may also be used over drilled or augered holes up to d. 450mm without any additional support.

The plates may be used on a supporting slab or planks of timber and earth, over large pits to provide a hygienic surface with a well fitted lid.

Each stack contains: -10 x Squatting Plates -10 x Squatting plate drop hole covers with handles -80 x cable ties -Packing list, users notes & leaflet. 1 pallet contains 6 stacks.

Specifications Injection molded polypropylene.

Options - Accessories Flushing bowl (not shown)is also available which allows connection to septic tanks or main sewer. One plate needs to be allowed for every 50 people

Page 85: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 403

Sprayer

Code Description Ind. price Ship. weight Ship. Vol. WSANSPRA05 SPRAYER, manual, hand held, 5l CHF62.40 WSANSPRA20 SPRAYER, Birchmeyer, type senior,20l CHF280.00 WSANSPRA20M SPRAYER, motorised, backback, 20l Cold chain: No Dangerous: No Regulated: No

General information Light, and resistant to a wide range of chemicals and atmospheres. UV resistant.

Good tolerance to an extensive list of chemical products.

Compression Type. Wide funnel shaped tank mouth for easy filling.

Pumped Type anatomical design for greater operator comfort during long hours of use.

Motorised type for large vector control campain.

Protective clothing should be available for all authorized personnel for XSO vector/chemical.

Specifications Maintenance kit & set of operator manuals in English and/or French. All manufactured in UV treated high-density polyethylene HDPE Robust piston pump with high output with fewer strokes per minute. Supplied with lance with adjustable nozzle, 1.2m hose & belt for carrying. Mechanical Mixer to maintain an evenly mixed solution. Safety valve to prevent over pressurizing of tank (max pressure 3 bar) With left or right hand pump lever action for steady, pulsation-free spraying. Pump chamber valve with diaphragm system gives complete sealing. Triple filtering: Top of the tank. Suction mechanism. Nozzle.

Options - Accessories Lance extensions, protective hoods & three nozzle booms for pumped type. Flat fan adaptor kit for compression type.

Page 86: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

404 Water and Sanitation

Fly catcher

Code Description Ind. price Ship. weight Ship. Vol. WSANFLYC001 FLY CATCHER, Fly City, to hang up +

attracting product CHF3.00

Cold chain: No Dangerous: Yes - Insecticide Regulated: Yes - Phytosanitary

General information Vector control device for sanitation program.

Page 87: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 405

Body bag

Code Description Ind. price Ship. weight Ship. Vol. WSANBODBUSH BODY BAG, U shaped zip bag, white

opaque, 220x80cm, 200um CHF10.25

Cold chain: No Dangerous: No Regulated: No

General information PVC bags for corpses.

Specifications Body bag made of strong PVC sheet. Full opening zipper, on 3 sides.

Page 88: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

406 Water and Sanitation

Lime, quick lime / slacked lime Code Description Ind. price Ship. weight Ship. Vol. DCHPLIMEQP5 LIME, QUICK, calcium oxide, powder,

5 kg box, IATA

DCHPLIMESP3 LIME, SLAKED, ca. hydroxide, powd., for water tr., 33 kg bag

Cold chain: No Dangerous: Yes – Quick lime Regulated: Yes – IATA quick lime

General information Quick lime is used for covering of decomposing organic matters in order to avoid putrefaction

smells and attraction of flies and various type scavengers.

- On corpses: If deep burial is not possible, first spread quick lime in the pit, then place the corpse and cover it with quick lime (1kg of lime per 10kg of corpse weight).

- Waste dumps: If covering with earth or incineration are impossible, spread quick lime at regular intervals.

- Excreta: Spread quick lime daily in defecation trenches when covering with earth or ash are impossible.

Slaked lime is used in large quantities for water pH adjustment, agriculture, building material.

Safety instructions for quick lime (same instructions as Chlorine HTH can apply):

- Irritating effect on skin and dangerous for eyes. In case of contact with eyes, wash immediately and abundantly with water. It could lead to irreversible damages, blindness.

- Dusts are dangerous for eyes and respiratory tract.

- Store and use out of reach of children.

- Protect from wind dispersal, i.e.: add a thin layer of earth on top of the lime.

Handling of quick lime:

- Only well aware and equipped people should manipulate quick lime.

- Needed equipment includes rubber gloves, boots, goggles, masks, overalls.

Local purchase highly recommended, especially for quick lime, which is a dangerous product to transport, thus expensive to pack under IATA regulations.

Beware of confusion with chlorinated lime which is a chlorine generating product and not lime.

Specifications Quick lime: Greyish blocks or granules, or white powder. Calcium oxide, CaO. Corrosive.

Transport regulated: Airplane transport according to IATA regulations under UN1910. Passenger aircraft: 25kg or 5kg packaging. Cargo only aircraft: 100kg packaging maximum. Slaked lime: White powder. Hydrated lime, Calcium hydroxyde Ca(OH)2.

Not regulated for transport. Packing: Bags of 50kg maximum, preferably bags of 25kg, for an easier handling.

Page 89: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 407

Insecticides

Code Description Ind. price Ship. weight Ship. Vol. DCHPDELT2WP3 DELTAMETHRIN, 'K-OTHRINE',

2.5%, wettable powder, 33 g sach. CHF3.50

DCHPDELT2WP8 DELTAMETHRIN, 'K-OTHRINE', 2.5%, wettable powder, 80 g sach.

DCHPDELTTM DELTAMETHRIN, 'K-O TAB', 1 tab.+ acc. for mosq. net treat.

CHF3.10

DCHPPERM5P2 PERMETHRIN, 0.5%, powder, 25 g, sachet

CHF0.76

Cold chain: No Dangerous: Yes Regulated: Yes - Phytosanitary

General information Insecticides used to reduce incidence of crawling and flying insects, in situation where insects have

become a public health hazard.

- Deltamethrine and Permethrine are synthetic pyrethroid with residual effect, depending on the use and application rate. Synthetic pyrethroids are highly toxic to fish, but have very low mammalian toxicity (deltamethrine LD50 in rats is 135mg/kg body weight, and much lower for solutions).

Deltamethrine or Permethrine are not considered very dangerous and can be handled by personnel who will observe routine safety measures.

Major difference between the 2 products:

- Deltamethrine to be used for large spraying campain. Cannot be used in powder form directly on the skin.

- Permethrine can be used in powder form directly on the skin.

Current usages

- Residual (adulticide) treatment against mosquitoes, houseflies, fleas, bedbugs and cockroaches.

- Impregnation of bednets.

- Dusting (bait) against fleas and cockroaches.

- Dusting against body lice (Permethrine only).

Page 90: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

408 Water and Sanitation

- Lotion and shampoo against lice.

- Wettable powder cannot be used when dusting clothes against body lice.

- Rates of application depend on the vector, formulation used, specific treatment chosen and substrate to spray. For advise on specific application rates,contact locally a vector control specialised company or MoH specialists or technical advisers from your HQ.

A large vector control program must be organised by a specialist.

The use of an insecticide must be accepted by the national authorities (MoH).

Some old type insecticides are still found in some places, despite international interdiction, like DDT. Do not use these products.

Specifications Commercial names of Deltamethrine includes: K-otrine, Decamethrin, NRDC161, Cistin and Decis. Available on the market in the following formulations: Water dispersible powder: 2.5% and 5.0% Emulsifiable concentrate: 2.5% and 5.0% Commercial names of Permethrine includes: Ambush, Coopex, Stomoxin. Available on the market in the following formulations: Dusting powder: 0.5% and 1% Water dispersible powder: 2.5% Emulsifiable concentrate: 2.5% and 5.0%

Options - Accessories WSANSPRA05 SPRAYER, manual, hand held, 5l WSANSPRA20 SPRAYER, Birchmeyer, type senior,20l WSANSPRA20M SPRAYER, motorised, backback, 20l

Page 91: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 409

Measuring instruments, for water and sanitation

Code Description Ref. WMEACLIN10 CLINOMETER,CLYSIMETER,360 DEG a WMEACOND20 CONDUCTIVITY METRE LF 330/SET complete b EMEAALTI30 ALTIMETER, analogic, 0-6000m, 10m precise c WMEALEVE10 LEVEL,Abney e WMEALEVE20 LEVEL Tecomat f WMEASRGW100G SOUNDING ROD FOR GROUND WATER, Geotrade, 100m g WMEATHEO10 THEODOLITE Zeiss h WMEATHEO10A (theodolite) ROD,GRADUATED, MEASURING, FLAT, TELESCOPIC i WMEATHEO10B (theodolite) ROD, GRADUATED, MEASURING, ROUND, TELESCOPIC j WMEATHEO10C (theodolite) TRIPODE k WMEATHEO10D (theodolite) TRIPODE UNIVERSAL l Cold chain: No Dangerous: No Regulated: No

Page 92: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

410 Water and Sanitation

Tripod, for well

Code Description Ind. price Ship. weight Ship. Vol. WTOOTRIP WELL TRIPOD, assembly Cold chain: No Dangerous: No Regulated: No

General information Basic element for construction of wells.

Use to raise and lower equipment and personnel.

Specifications Tripod for well, with manual cable winch with minimum 25m cable (or as per request) Minimum capacity of 1500kg Winch with cable on coil, plus brake and work-back ratchet preventing system Approved by national certified inspection company.

Page 93: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 411

Emergency Response Unit, Water and Sanitation Code Description Ind. price Ship. weight Ship. Vol. ERU, Water and Sanitation, complete CHF 921’000 38 MT 155 m³ Cold chain: No Dangerous: Yes. Chemicals Regulated: Yes. IATA packages

General information The complete Water and Sanitation ERU is composed of 4 modules:

- ERU, Water and Sanitation, Treatment and Supply module

- ERU, Water and Sanitation, Water Distribution and Trucking

- ERU, Water and Sanitation, Specialised Wat-San

- ERU, Water and Sanitation, Mass Sanitation

Each module is self-standing and can be ordered separately according to the situation needs.

Inside each module, some parts are not self-standing if separated from the rest of the module. Thus, it is not recommended to split a module.

Re-supply of consumables or order of specific items or kits should be based on the general item list (see chapter W of this catalogue).

All transport regulated products are packed for the highest constraint, that is air transport on passenger/cargo mix aircraft. They have their IATA certificates inside the set of document of each ERU module.

Total weight and volume of the complete WatSan ERU as shown in above table fits in a cargo plane of 40tons/180m3 such as B707 or IL76 or equivalent.

See also: Operating Manual and Part’s List, issue 2002

Specifications As per the individual specifications of each items. Refer to respective item sheets.

See next pages the detail of each module.

Page 94: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 413

Emergency Response Unit WatSan Water treatment and supply module

Code Description Ind. price Ship. weight Ship. Vol.

ERU, Water and Sanitation, Treatment and Supply module

CHF 150’000 (for the 2 lines)

13MT 50m³

Cold chain: No Dangerous: Yes - Chemicals Regulated: Yes - IATA

General information The complete Water and Sanitation ERU is composed of 4 modules:

- ERU, Water and Sanitation, Treatment and Supply module

- ERU, Water and Sanitation, Water Distribution and Trucking

- ERU, Water and Sanitation, Specialised Wat-San

- ERU, Water and Sanitation, Mass Sanitation

The purpose of the Treatment and Supply module is to provide safe drinking water for up to 40,000 beneficiaries in emergency situations.

The module has the maximum capacity to treat, supply and store up to 600,000 litres of water per day. The water quality meets WHO/SPHERE drinking water standards.

The module consists of 2 identical supply lines as per sketch next page (1 supply line provides 20,000 beneficiaries). The list of content includes 2 supply lines. An assembly of only 1 supply line can be ordered, specify on your order.

It covers the principal tasks of pumping raw water to large storage tanks where sedimentation and chemical treatment takes place and to store and distribute either by gravity or through pumping to large populations.

Indicative staffing patterns

- 1 team leader (Wat-San engineer)

- 4 general technicians (technician, plumber, electrician, chemical engineer)

- 1 logistician (optional)

The module consists of a series of different kits, each having its own function. The list below shows the split of the module per kit. Each kit has its own package.

Page 95: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

414 Water and Sanitation

General arrangement drawing for 1 supply line

Supplied with: ● Adaptation and spares kit ● Pumping oil and tool kit ● 180m additional pipe ● Tank and pipework tool kit ● Chemicals ● Chlorination kit ● Water testing equipment

Pumping pipework

2” pump kit P

70 70

95

10 10

5 5

2 x 70m³ tank kit

Link pipework kit

95m³ tank kit

2 x 5m³ transport and storage bladder kits

2” pump kit

Distribution pipework

P

6 x tapstand kits

Π

Π Π

Π

Π Π

Page 96: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 415

Pipework sizes drawing, only 1 line shown

Supplied with: ● An extra 180m of 3” suction/supply hose is available for use wherever it is required plus 100m of 2½” layflat hose. ● A full range of spares and adapters are supplied for use wherever required and for connection to any other system.

Pumping pipework

Pumping pipework 3” suction/ supply hose, total 60 metres

P

70 70

95

10 10

5 5

Link pipework kit

Supplied with 5m³ bladder 3” suction/supply hose, total, 15m

Distribution pipework 63mm MDPE pipe, total 160m

P

Π

ΠΠ

Π

ΠΠ

Link pipework 3” suction/ supply hose, total 30 metres

10m max.

Pumping pipework 3” suction/ supply hose, total 60 metres

Supplied with 10m³ bladder 3” suction/supply hose, total, 15m

Supplied with tapstand 32mm MDPE pipe, total, 12m

Page 97: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

416 Water and Sanitation

Specifications As per the individual specifications of each items. Refer to respective item sheets.

Module content list

Code Description Qty

1 line

Qty

2 lines

Ship.Weight

Per unit

Ship. Vol.

Per unit

KWATPUMCERU1 KIT, MOTOR PUMP, diesel, 2", water and sanitation ERU

3 5 100kg 0.70 x 0.50 x 0.75m 0.26m³

KWATNEACPP01 KIT, PUMPING PIPEWORK, water and sanitation ERU

2 4 219kg 1.47 x 1.47 x 0.82m 1.78m³

KWATTOOLPU01 KIT, TOOL + ENG.OIL, for pumping set up, wat. and sanit. ERU

1 2 223kg 1.47 x 0.71 x 0.9m 0.94m³

KWATTANKR70 KIT, WATER TANK, 70 m3, rigid, corrugated

2 4 677kg Box 1.47x 0.71x 0.9m Pallet 2.93x 0.82x 0.56m

2.29m³ KWATTANKR95 KIT, WATER TANK, 95 m3, rigid,

corrugated 1 2 819kg Box 1.47x 0.71x 0.98m

Pallet 2.93x 0.82x 0.58m 2.43m³

KWATTANKRFI3 KIT, TANK LINKING PIPEWORK, 3”, for 3 rigid tanks

1 2 227kg 1.47x 1.47 x0.45m 0.98m³

KWATTANKRTO1 KIT, TOOLS, for rigid corrugated water tanks

1 2 Included in KWATTTOOLPU01

KWATTREACH01 KIT, CHLORINATION, water and sanitation ERU

1 2 Included in KWATTANKRFI3

KWATTANKP05T KIT, WATERTANK, flexible pillow, 5m3, transport/storage

2 2 150kg 1.47x 1.47x 0.45m 0.98m³

KWATTANKP10 KIT, WATERTANK, flexible pillow, 10m3, storage

2 2 186kg 1.47x 1.47x 0.45m 0.98m³

KWATRAMP06AP KIT, 1 TAPSTAND + PIPEWORK, water and sanit. ERU

6 12 44kg 0.20m³

KWATNEACDP01 KIT, DISTRIBUTION PIPEWORK, water and sanit. ERU

1 2 126kg 1.9 x 1.9 x 0.37m 1.34m³

KWATNEACAS01 KIT, ADAPTORS AND SPARES, water and sanit. ERU

1 1 Included in KWATTTOOLPU01

WNEHPVSP330T HOSE, PVC flexible spiralled, 2 con. thread. 3" mal/fem, 30m

6 9 64kg each coil

0.63m³ each

KWATTREAWT01 KIT, WATER TESTING EQUIPMENT , water and sanit. ERU

1 1 N/a N/a

KWATTREASC01 KIT, START UP CHEMICALS, water and sanit. ERU

1 2 1000kg 2m³

Page 98: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 417

Kit content lists KWATPUMCERU1 KIT, MOTOR PUMP, diesel, 2”, water and sanitation ERU WPUCLOMB003 PUMP, diesel, Lombardini Swallow 5100, 2", 24m3/12m 1

WNECGATT2FFF COUPLING, GALVA, TEE, 2", threaded fem/fem/fem 1

WNECGACR2M1F COUPLING, GALVA, REDUCER, 2"-1", thread male/fem 1

WNECGANN1MM COUPLING, GALVA, NIPPLE, 1", threaded male/male 1

WNEVBRGA1FF VALVE, GATE, brass, 1", threaded fem/fem 1

KWATPUMCSP08 KIT, SPARE PART, pump Swallow 5100 Lombardini 15LD350, 2000h 1 Including: WSPPLOMBSWMS MECHANICAL SEAL, Swallow 5100 pump 1

WSPPLOMBSWVA VALVE, rubber, Swallow 5100 pump 1

WSPPLOMB3647 FUEL FILTER, element, Lombardini 15LD/3LD, ref SK3647 3

WSPPLOMB5155 OIL FILTER, element, Lombardini 15LD350, ref SO5155 3

WSPPLOMB1961 AIR FILTER, element, Lombardini 15LD350, ref SL1961 3

WSPPLOMBGUSW USER + SPARE PART GUIDE, Swallow 5100 1 KWATNEACPP01 KIT, PUMPING PIPEWORK, water and sanitation ERU Suction WNECGACR4F3F COUPLING, GALVA, REDUCER, 4"-3", threaded fem/fem 1

WNEASTNR3 STRAINER + check valve, 3", thread fem. 1

WNECSTCR3-2 COUPLING, 'Storz', REDUCER, 3"-2" 1

WNECSTCC3SF COUPLING, 'Storz', 3", threaded female 2

WNEHPVSP330T HOSE, PVC flexible spiralled, 2 con. thread. 3" mal/fem, 30m 1

WNECGABB2F2F COUPLING, GALVA, BEND, 2", 90°, thr fem/fem, large radius 1

WNECGANN2M2M COUPLING, GALVA, NIPPLE, 2", threaded male/male 2

WNECGANN4M4M COUPLING, GALVA, NIPPLE, 4", threaded male/male 1

WNECGACR3M2M COUPLING, GALVA, REDUCER,3"-2",threaded male/male 1

Discharge WNEHPVSP330T HOSE, PVC flexible spiralled, 2 con. thread. 3" mal/fem, 30m 1

WNEVBRGA3FF VALVE, GATE, brass, 3", threaded fem/fem 1

WNECGACR4M3F COUPLING, GALVA, REDUCER, 4"-3",ND100/ND80,threaded male/fem 1

WNECGACR3M2F COUPLING, GALVA, REDUCER, 3"-2", thred male/fem. 1

WNECSTCC3SM COUPLING, 'Storz', 3", threaded male 2

WNECGAEE3M3M COUPLING, GALVA, ELBOW, 3", 90°, thr.male/male, small radius 2

WNECGANN3M3M COUPLING, GALVA, NIPPLE, 3", threaded male/male 1

WNECSTCC3SF COUPLING, 'Storz', 3", threaded female 1

WNECGANN2M2M COUPLING, GALVA, NIPPLE, 2", threaded male/male 1

WNECGANN4M4M COUPLING, GALVA, NIPPLE, 4", threaded male/male 1

WNEHPVSP1/215 HOSE, PVC flexible reinforced, clear, 1/2"x15m 1

Page 99: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

418 Water and Sanitation

WNECGACR3M1F COUPLING, GALVA, REDUCER, 3"-1", ND80/ND25, thread male/fem 1

WNECBRCA1M1/2T COUPLING, BRASS, ADAPTOR, threaded male 1" to hose tail 1/2" 1

WNECGATT3FFF COUPLING, GALVA, TEE, 3", ND80, threaded fem/fem/fem 1

WNECGANN3M3M COUPLING, GALVA, NIPPLE, 3", threaded male/male 2

WNEABACL015 BAND CLIP, high pressure, 15-20mm 2

WNEVBRGA1FF VALVE, GATE, brass, 1", threaded fem/fem 1

WNECGANN1MM COUPLING, GALVA, NIPPLE, 1", threaded male/male 1 KWATTOOLPU01 KIT, TOOL + ENG.OIL, for pumping set up, wat. and sanit. ERU ETOOKEYS200 PIPE WRENCH, strap nylon, max. 200 mm opening 2

ETOOKEYS6 PIPE WRENCH, adjustable grip head, max. 140 mm opening 1

ETOOSAWSM150 HACKSAW, JUNIOR, for 150mm blades with 1 blade 1

ETOOSAWSM150B BLADE, for junior hacksaw, 150mm long, 10 teeth/cm 10

ETOOWRENV28O SPANNER, adjustable, max. 28mm opening 1

ETOOSCDRF65 SCREWDRIVER, flat blade of 6.5 x 150mm 1

ETOOWREN7/16 SPANNER, SET, combinaison, 7/16 - 3/4", A.F. 1

ETOOWREN1/4 SPANNER, combinaison, 1/4" 1

ETOOKEYSH7/32 KEY, hexagonal male "Allen", 7/32" 1

ETOOKEYSH3/16 KEY, hexagonal male "Allen", 3/16" 1

ETOOKEYSH3M KEY, hexagonal male "Allen", 3mm 1

ETOOPLIEUN20 PLIER universal 180 mm length, plastic sheats 1

ETOOMEAS19BL FEELER GAUGE, set of 19 blades from 0.04 to 1 mm, metric 1

ETOOLUBRC35 OIL CAN, 350ml, with pump and rigid oulet, aluminium body 1

WNECSTHO2-3 (coupling Storz) HOOK SPANNER, 2"-3" 1

WTOOSPANSWIV SPANNER, ring type, for swivel fittings 1

ETOOHAMMWOMA WOODEN MALLET 1

TVECLUBRO26 OIL, ENGINE, diesel/petrol, 15W40, jerrican 5lt 10

TVECJCANM20 JERRYCAN, 20 l, metallic 1

TVECMVACBT20 FUNNEL, dia. 200 mm, bended + metallic filter 1

TVECMVACBT19 FUNNEL, dia. 80 mm, plastic 1 KWATTANKR70 KIT, WATER TANK, 70 m3, rigid, corrugated KWATTANKR95 KIT, WATER TANK, 95 m3, rigid, corrugated Lists of contents for 1 unit of tank: Pack 1: KIT STEEL 70m³ 95m³ WWAKRTOXIS01 IRON SHEET, corrugated, for rigid tank 45/70/95m3 18 25

WWAKRTOXIS02 IRON SHEET, corrugated, for rigid tank 45/70/95m3, + outlets 3 3 Pack 2: KIT LINER +ACCESSORIES 70m³ 95m³ WWAKRTOXCA12 SPLIT CAPPING, PVC, d:12mm, per metre length 21 21

WWAKRTOXCA25 SPLIT CAPPING, PVC, d:25mm, per metre length 21 21

EHDWCLIP25 CLIP, spring clips, 25mm 60 60

Page 100: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 419

EHDWBOLTGR01 BOLT, galva, round head with slot drive, d:10mm, L:20mm 560 780

EHDWNUTSG10- NUT, galva, hexagonal, d:10mm, size: 17mm 560 780

EHDWWASHF10 WASHER, galva, flat, d:10mm 560 780

ETOOPODG01 PODGER, spike to align iron sheet bolt holes 1 1

WNEVBRGA3FF VALVE, GATE, brass, 3", threaded fem/fem 1 1

APACSCOT50RB TAPE, adhesive, canvas reinforced, 55mm, roll 50m, black 2 2

WNECIRFL3ASS CONNECTOR, FLANGE ASSEMBLY, 3”, complete set 3 3

Each including:

WNECIRFL3M90 CONNECTOR, 3”, pipe L:90mm threaded male, flanged, 4 x M10 1 1

WNECIRFL3M FLANGE, counterplate, 3”, 4 plain holes d: 10mm 1 1

WNECIRFL3G (3" flange) GASKET, 2mm thick rubber, 4 holes 10mm 2 2

EHDWBOLTS161 STUD, galva, d:16mm, L: 100mm 4 4

EHDWNUTSG16- NUT, galva, hexagonal, d: 16mm, size: 24mm 8 8

EHDWWASHF16 WASHER, galva, flat, d:16mm 8 8

WWAKRTOXL70 LINING, 70m3, EPDM reinforced synth. rubber, thick: 1.25mm 1 0

WWAKRTOXL95 LINING, 95m3, EPDM reinforced synth. rubber, thick: 1.25mm 0 1

KWATREPAEPLI REPAIR KIT, for rigid water tank EPDM rubber liners 1 1

Including:

WWAKREPAEPSH EPDM MATERIAL SPARE, 1 x 1m 1 1

WWAKREPAEPTA ADHESIVE TAPE, to repair EPDM liners, 50mm x 10m 1 1

WTOOSEALTEFL SEAL TAPE, 'Teflon', for water connectors, roll 12mm x 12m 1 1

WWAKRTOXGUIDE MANUAL, Oxfam Water Storage Pack, in a plastic bag 1 1 Pack 3: KIT CONICAL ROOF 70m³ 95m³ WWAKRTOXRO75 ROOF, PVC coated polyester 500gr/m2, d:7.5m, + 28 eyelets 1 1

HSHEROPE06P ROPE, polypropylene, black, d:6mm, per metre length 300 300

WWAKRTOXROC1 COLUMN SECTION, plastic, d:100mm, L: 1m 3 4

WWAKRTOXTOPL TOP PLATE, for roof central support 2 2

WWAKRTOXROCC CONNECTOR, straight, for plastic column d:100mm 2 3

EHDWVHDWEY10 EYE NUT, M10 28 28

WWAKRTOXBAPL BASE PLATE, for roof central support 1 1

KWATREPAF01 KIT, REPAIR, for PVC flexible reinforced material 1 1 KWATTANKRFI3 KIT, TANK LINKING PIPEWORK, 3”, for 3 rigid tanks WNECPVTT80FFF COUPLING, PVC, TEE, 3” ND80, NP6, threaded fem/fem/fem 2

WNECPVNN80FF COUPLING, PVC, NIPPLE, 3” ND80, NP6, threaded male/male 13

WNECPVCP80F COUPLING, PVC, CAP, 3” ND80, NP6, threaded fem 2

WNECBRCA3M3T COUPLING, BRASS, ADAPTOR, 2 pces, thr. fem. 3"/hose tail 3" 10

WNEABACL80-100 BAND CLIP, high pressure, 80-100mm 12

WNECCOCP3M90 COUPLING, COMPRESSION, 3”, thread male to pipe d.ext.: 90mm 1

WNECPVEE80FF COUPLING, PVC, ELBOW, 3” ND80, NP6, threaded fem/fem 2

WNEHPVRI8005 PIPE, PVC, 3” ND80, NP6, L: 500mm, threaded male one end 1

WNEHEPSP3-20 HOSE, PVC, SPIRALLED, suction/delivery, 3" x 20m 1

WNEVBRGA3FF VALVE, GATE, brass, 3", threaded fem/fem 2

WTOOSEALTEFL SEAL TAPE, 'Teflon', for water connectors, roll 10mm x 30m 2

Page 101: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

420 Water and Sanitation

Included above: KWATTANKRTO1 KIT, TOOLS, for rigid corrugated water tanks ETOOKEYSFJ110 HANDLE, BRACE, for 3/8" square drive sockets 1

ETOOSOCK12P17J SOCKET 17 mm 3/8" 12 points 2

ETOOKEYSF40.17 SPANNER, COMBINATION, 17 mm ring, 15° angled, open and ring end 2

ETOOKEYSF40.24 SPANNER, COMBINATION, 24 mm ring, 15° angled, open and ring end 2

ETOOSCDRF6.5X20 SCREWDRIVER, flat head 6,5x200mm 2

ETOOFILEHRC200 FILE, HALF-ROUND, coarse, 200mm long 1

ETOOFILEN160 FILE, NEEDLE, knife cut, 160mm long 1

ETOOCUTTH HACKSAW, builder type, with 1 blade, L: 300mm 1

ETOOCUTTHB (hacksaw) BLADE, HSS, 10 teeth / cm, 300mm 3

ETOOCUTTL5 CUTTER, retractable, interchangeable blade, 150mm, alu. body 1

ETOOCUTTL5B (cutter alu 150mm) BLADE, normal cut 5

ETOOKEYS200 PIPE WRENCH, strap nylon, max. 200 mm opening 2

ETOOMEASLS40 LEVEL aluminium 400 mm standard 1

ETOOMEASLL01 LEVEL, line level 1

ETOOMEASLP18 LINE PINS with 18m of line, PAIR 1

ETOOSCISSTD1 SCISSORS, std, 105mm, one pair 1

APROGLOVHDL10 GLOVES, protection, heavy duty leather, size 10 3

ETOOWRENV28O SPANNER, adjustable, max. 28mm opening 2

ETOOKEYSP2.5 WRENCH for PIPE open.65mm, length 18" 450mm with teeth 1

ETOOSAWSM150 HACKSAW, JUNIOR, for 150mm blades with 1 blade 1

ETOOSAWSM150B BLADE, for junior hacksaw, 150mm long, 10 teeth/cm 3

ETOOCUTTSF300 PLANE, SURFORM, 300mm 1

ETOOCUTTSF300B (surform 300mm) BLADE 2

ETOOKEYS6 PIPE WRENCH, adjustable grip head, max. 140 mm opening 1

WNECSTHO2-3 (coupling Storz) HOOK SPANNER, 2"-3" 4

ETOOLADD4500 LADDER, aluminium extendable, 4.5m 1

ETOOKEYSH6L KEY, hexagonal male, "Allen" 6mm, long shank 6

WTOOSPANSWIV SPANNER, ring type, for swivel fittings 1 KWATTREACH01 KIT, CHLORINATION, water and sanitation ERU WWTEDOSI001 FLOATING CONTAINER for slow dissolving chlorine 3

DASDCHLA7T2 CHLORE (HTH), 60 to 70%, 5 x 200 g tab., slow dissolve 10

WMEAPOOL10 POOL TESTER + accessories 1

WMEAPOOL10A (pool test) TABLET DPD1 for dosing free chlorine 200

WWAKWLABGUIDE GUIDELINE, Oxfam guide to chlorination 1

Page 102: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 421

KWATTANKP05T KIT, WATERTANK, flexible pillow, 5m3, transport/storage WWAKFLPT05T WATERTANK, flexible pillow, PVC, transport/storage, 5 m3 1

WNEVBRGA3FF VALVE, GATE, brass, 3", threaded fem/fem 2

WNEHPVSP315T HOSE, PVC flexible spiralled, 2 con. thread. 3" mal/fem, 15m 1

WNECGATT3FFF COUPLING, GALVA, TEE, 3", ND80, threaded fem/fem/fem 1

WNECGANN3M3M COUPLING, GALVA, NIPPLE, 3", threaded male/male 3

WWAKFLPT05GS (pillow tank 5m3) GROUND SHEET 1

WWAKFLPT05TH (pillow tank 5m3) HARNESS, for trucking 1

WNECSTCC3SM COUPLING, 'Storz', 3", threaded male 1

WNECSTCC3SF COUPLING, 'Storz', 3", threaded female 1 KWATTANKP10 KIT, WATERTANK, flexible pillow, 10m3, storage WWAKFLPT10 WATERTANK, flexible pillow, PVC, storage, 10 m3 1

WNEVBRGA3FF VALVE, GATE, brass, 3", threaded fem/fem 3

WNEHPVSP330T HOSE, PVC flexible spiralled, 2 con. thread. 3" mal/fem, 30m 1

WNECGATT3FFF COUPLING, GALVA, TEE, 3", ND80, threaded fem/fem/fem 1

WNECGANN3M3M COUPLING, GALVA, NIPPLE, 3", threaded male/male 3

WWAKFLPT10GS (pillow tank 10m3) GROUND SHEET 1 KWATRAMP06AP KIT, 1 TAPSTAND + PIPEWORK, water and sanit. ERU KWATRAMP06A KIT, WATER TAP STAND, 6 automatic taps 1

WNEPPESR32 PIPE, MDPE polyethylene, d.ext: 32mm, NP10, coil, per meter 12

WNECCOCR32C1M COUPLING, COMPRESSION, thread. male 1" to pipe d.ext 32mm 4

WNECGATT2FF1F COUPLING, GALVA, TEE, reduced, 2" - 1", thread fem/fem/fem 1

WNECCOCR2M63 COUPLING, COMPRESSION, thread. male 2" to pipe d.ext:63mm 2

WTOOSEALTEFL SEAL TAPE, 'Teflon', for water connectors, roll 12mm x 12m 1

WNECGACP2M COUPLING, GALVA, PLUG, 2", threaded male 1

WNEVBRGA1FF VALVE, GATE, brass, 1", threaded fem/fem 1

WNECCOCC32CC1 COUPLING, COMPRESSION, socket, for MDPE hose d. ext: 32 1

WNECCOTT32CCC COUPLING, COMPRESSION, Tee, for pipe d. ext: 32mm 1

WNECGACR3M1F COUPLING, GALVA, REDUCER, 3"-1", ND80/ND25, thread male/fem 1

WNECGACR3F1F COUPLING, GALVA, REDUCER, 3"-1", ND80/ND25, threaded fem/fem 1 KWATNEACDP01 KIT, DISTRIBUTION PIPEWORK, water and sanit. ERU WNEPPESR63 PIPE, MDPE polyethylene, d.ext: 63mm, NP10, coil, per meter 160

WNECGACR3M2M COUPLING, GALVA, REDUCER,3"-2",threaded male/male 2

WNECGATT2FFF COUPLING, GALVA, TEE, 2", threaded fem/fem/fem 2

WNECCOCR2M63 COUPLING, COMPRESSION, thread. male 2" to pipe d.ext:63mm 4

Page 103: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

422 Water and Sanitation

WNECCOCP63 COUPLING, COMPRESSION, PLUG, for d.ext: 63mm 4

WNEHSBFL325T HOSE, SBR, FLAT, delivery, 3", +2 threa. coup. male/fem, 25m 4

WNEVBRGA3NOZ VALVE 1/4 turn + CONNECTOR + NOZZLE, 3" thr. male/3" nozzle 1

KWATREPASBFL KIT, REPAIR, for SBR layflat hose pipe 2 KWATNEACAS01 KIT, ADAPTORS AND SPARES, water and sanit. ERU WNEVBRGA3FF VALVE, GATE, brass, 3", threaded fem/fem 2

WNECGANN3M3M COUPLING, GALVA, NIPPLE, 3", threaded male/male 4

WNECSTCR3-2 COUPLING, 'Storz', REDUCER, 3"-2" 2

WNECGATT3FFF COUPLING, GALVA, TEE, 3", ND80, threaded fem/fem/fem 2

WNECSTCC3SM COUPLING, 'Storz', 3", threaded male 12

WNECSTCC3SF COUPLING, 'Storz', 3", threaded female 12

WNECGATT2FFF COUPLING, GALVA, TEE, 2", threaded fem/fem/fem 1

WNECCOCR2M63 COUPLING, COMPRESSION, thread. male 2" to pipe d.ext:63mm 5

WMEAPRES10 GAUGE, PRESSURE, for water, 10bar, + adapt. thread male 1" 1

WNECGATT3FF1F COUPLING, GALVA, TEE, reduced, 3"-1", thread fem/fem/fem 1

WNEVBRGAV1MF VALVE, VENT, for pressure gauge, 1" thred mal/fem 1

WNECGANN3M3M COUPLING, GALVA, NIPPLE, 3", threaded male/male 2

WMEAFLOW2F FLOWMETER, 2", threaded female 1

WNEABACL077 BAND CLIP, high pressure, 77-95mm 8

WNECGATT3FFF COUPLING, GALVA, TEE, 3", ND80, threaded fem/fem/fem 2

WNECCOCR32C1M COUPLING, COMPRESSION, thread. male 1" to pipe d.ext 32mm 3

WNECGACR3F2M COUPLING, GALVA, REDUCER, 3"-2", threaded fem/male 3

WNECGACR3M2F COUPLING, GALVA, REDUCER, 3"-2", thred male/fem. 3

WNECCOCC63 COUPLING, COMPRESSION, socket, for MDPE hose d. ext: 63mm 5

WNEVBRGA1FF VALVE, GATE, brass, 1", threaded fem/fem 1

WNECGATT3FF1F COUPLING, GALVA, TEE, reduced, 3"-1", thread fem/fem/fem 1

WNEVBRGA3FF VALVE, GATE, brass, 3", threaded fem/fem 1

WNECCOCR3M63 COUPLING, COMPRESSION, thread. male 3" to pipe d.ext:63mm 2

KWATREPASBFL KIT, REPAIR, for SBR layflat hose pipe 2

WNECBRCA3F3T COUPLING, BRASS, ADAPTOR, 2 pces, thr. fem. 3"/hose tail 3" 4

WNECBRCA3M3T COUPLING, BRASS, ADAPTOR, thread. male 3" to hosetail 3" 4

WNECBRCA3G (hosetail coupling 3") GASKET WASHER 10

WTOOSEALHE HEMP, for plumbing, 500g 5 KWATTREAWT01 KIT, WATER TESTING EQUIPMENT , water and sanit. ERU KWATWLABDELA KIT, WATER TESTING, "Delagua", incubator 37 & 44°C 1 Including: KWATWLABPOST KIT, STERILIZER, use with water microbio. tests 1

WWATWLABABP ABSORBENT PADS, for 200 tests, with distributor 5

WWATWLABMFIL MEMBRANE FILTER, 0.45ms, 47mm, cross ruled, pack of 200 5

WWATWLABABPD DISPENSER, for absorbant pads 5

Page 104: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 423

WWATWLABMF500 ABSORBANT PAD, lauryl sulfate impregnated, dehyd., 50pces 5

WMEAPOOL10A (pool test) TABLET DPD1 for dosing free chlorine 250

WMEAPOOL10C (pool test) TABLET RED PHENOL for PH control 250

WMEAPOOL10 POOL TESTER + accessories 1

EELEFUSEG605 FUSE, glass type, 5 A. (6.3 x 32 mm) 2

XLABBOTL005P BOTTLE POLYETHYLENE, 50 ml with screw cap, pce 50

XLABBOTL01P BOTTLE POLYETHYLENE, 100 ml with screw cap, pce OR

XLABBOTL02P BOTTLE POLYETHYLENE, 250 ml with screw cap, pce OR

XLABBOTL1P BOTTLE POLYETHYLENE, 1000 ml with screw cap, pce OR

CHLORINE TESTING, Merck Microquant Nr.14826

PH TESTING, Merck Aquamerck Nr.8038 – wider range 4,5-9,0

CONDUCTIVITY AND PH: Lovibond chekit Mikro pH+ and µS

Range for conductivity tester: 0 – 20000 µS

Refilling pack for Cl, pH, Al: Only the chemicals which are needed for the tests

Chlorine: Merck Spectroquant Nr. 14828 (DEM200)

PH: Merck Aquamerck Nr.8043 (DEM40)

Al: Merck Microquant Nr. 14824 (DEM200)

THERMOMETER

PH INDICATOR STRIPS, Merck Nr.9535, pH0-14, DEM 15

GLASS BOTTLES, sterilisable, including glass stopper

SAMPLE BAGS, STERILE, (e.g. Whirlpak)

PLASTIC BOTTLE, from small up to 1 litre

BUCKETS

SCALES (simple for weighing small quantities) KWATTREASC01 KIT, START UP CHEMICALS, water and sanit. ERU DCHPLIMESP3 LIME, SLAKED, ca. hydroxide, powd., for water tr., 33 kg bag 6

DCHPALUSG50 ALUM. SULFATE, granulates, 50 kg bag 20

DASDCHLA7G5 CHLORE (HTH), 60 to 70%, granulates, 5 kg box, IATA 100

APACIATAB01 EXTRA PACKAGE, IATA, for aluminium sulfate 50kg granules 20

APACIATAB02 EXTRA PACKAGE, IATA, for slaked lime 33kg powder 6

Page 105: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 425

Emergency Response Unit WatSan Water distribution and trucking module

Code Description Ind. price Ship. weight Ship. Vol. No code ERU, Water and Sanitation, water

Distribution and Trucking CHF 80’000 5MT 18m³

Cold chain: No Dangerous: No Regulated: No

General information The complete Water and Sanitation ERU is composed of 4 modules:

- ERU, Water and Sanitation, Treatment and Supply module

- ERU, Water and Sanitation, Water Distribution and Trucking

- ERU, Water and Sanitation, Specialised Wat-San

- ERU, Water and Sanitation, Mass Sanitation

The purpose of the water Distribution and Trucking module is to enable flexible storage and distribution of drinking water which is detached from the treatment set-up. Especially designed for those circumstances where the availability of safe drinking water is less of a problem but the dispersement of the beneficiaries into smaller settlement areas causes a distribution problem.

The module has the capacity to store and distribute 75,000 litres of drinking water per day to 9 identical storage and distribution systems at 9 different locations.

Specially designed bladder/pillow tanks are used for transport of water by trucks (trucks have to be locally hired or purchased). The drinking water is pumped from the trucks into storage tanks. The trucks will rotate to the storage tanks at the different distribution sites. Water is then distributed to the beneficiaries via tap stands. The module is not designed to treat raw water!

Indicative staffing patterns

- The module will in most cases be deployed together with the Treatment and Supply Module so no additional staff are required.

- Should the module be deployed on its own, 2 general technicians would be needed.

The module consists of a series of different kits, each having its own function. The lists here below show the split of the module per kit. Each kit has its own package.

Page 106: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

426 Water and Sanitation

General arrangement drawing

Trucking equipment – 3 sets

Distribution equipment – 9 sets

5

P

P

2” lightweight pump and pipework kit carried on truck 3 off plus 1 spare per module

5m³ transport and storage bladder mounted on local truck 3 off per module

2” pump kit

Pumping pipework kit Set-up at depot to fill bladder 1 off per module

10 12m of 32mm pipe

Tapstand kit

Red Cross T10 steel tank kit

Tapstand kit

Alternative 10m³ bladder tank

10

OR

Page 107: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 427

Specifications As per the individual specifications of each items. Refer to respective item sheets.

Module content list

Code Description Qty Ship. Weight

Per unit

Ship. Vol.

Per unit KWATPUMCERU1 KIT, MOTOR PUMP, diesel, 2", water and

sanitation ERU 1 100kg 0.7 x 0.50 x 0.74m

0.26m³ KWATNEACPP01 KIT, PUMPING PIPEWORK, water and

sanitation ERU 1 219kg 1.47 x 1.47 x 0.82m

1.78m³ KWATTOOLPU01 KIT, TOOL + ENG.OIL, for pumping set up, wat.

and sanit. ERU 1 Included in

KWATTTOOLPU01 KWATPUMCERU2 KIT, MOTOR PUMP, diesel, lightweight, +

PIPES 4 51kg 0.25m³

KWATTANKP05T KIT, WATERTANK, flexible pillow, 5m3, transport/storage

3 160kg 1.47x 1.47x 0.45m 0.98m³

KWATRAMP06AP KIT, 1 TAPSTAND + PIPEWORK, water and sanit. ERU

9 44kg 1x 0.81x 0.24m 0.20m³

KWATTANKRTO1 KIT, TOOLS, for rigid corrugated water tanks 1 Included in KWATTANKR10

KWATTANKR10 KIT, WATER TANK, 10 m3, rigid, corrugated

9 303kg 1.53x 0.86x 0.57m 0.75m³

KWATNEACAS01 KIT, ADAPTORS AND SPARES, water and sanit. ERU

1 Included in KWATTTOOLPU01

Alternatively to replace the rigid corrugated 10m3 water tank: KWATTANKP10 KIT, WATERTANK, flexible pillow, 10m3,

storage 9 186kg 1.47x 1.47x 0.46m

Kit content lists KWATPUMCERU1 KIT, MOTOR PUMP, diesel, 2”, water and sanitation ERU WPUCLOMB003 PUMP, diesel, Lombardini Swallow 5100, 2", 24m3/12m 1

WNECGATT2FFF COUPLING, GALVA, TEE, 2", threaded fem/fem/fem 1

WNECGACR2M1F COUPLING, GALVA, REDUCER, 2"-1", thread male/fem 1

WNECGANN1MM COUPLING, GALVA, NIPPLE, 1", threaded male/male 1

WNEVBRGA1FF VALVE, GATE, brass, 1", threaded fem/fem 1

KWATPUMCSP08 KIT, SPARE PART, pump Swallow5100Lombardini 15LD350, 2000h 1 Including: WSPPLOMBSWMS MECHANICAL SEAL, Swallow 5100 pump 1

WSPPLOMBSWVA VALVE, rubber, Swallow 5100 pump 1

WSPPLOMB3647 FUEL FILTER, element, Lombardini 15LD/3LD, ref SK3647 3

WSPPLOMB5155 OIL FILTER, element, Lombardini 15LD350, ref SO5155 3

WSPPLOMB1961 AIR FILTER, element, Lombardini 15LD350, ref SL1961 3

WSPPLOMBGUSW USER + SPARE PART GUIDE, Swallow 5100 1

Page 108: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

428 Water and Sanitation

KWATNEACPP01 KIT, PUMPING PIPEWORK, water and sanitation ERU Suction WNECGACR4F3F COUPLING, GALVA, REDUCER, 4"-3", threaded fem/fem 1

WNEASTNR3 STRAINER + check valve, 3", thread fem. 1

WNECSTCR3-2 COUPLING, 'Storz', REDUCER, 3"-2" 1

WNECSTCC3SF COUPLING, 'Storz', 3", threaded female 2

WNEHPVSP330T HOSE, PVC flexible spiralled, 2 con. thread. 3" mal/fem, 30m 1

WNECGABB2F2F COUPLING, GALVA, BEND, 2", 90°, thr fem/fem, large radius 1

WNECGANN2M2M COUPLING, GALVA, NIPPLE, 2", threaded male/male 2

WNECGANN4M4M COUPLING, GALVA, NIPPLE, 4", threaded male/male 1

WNECGACR3M2M COUPLING, GALVA, REDUCER,3"-2",threaded male/male 1

Discharge WNEHPVSP330T HOSE, PVC flexible spiralled, 2 con. thread. 3" mal/fem, 30m 1

WNEVBRGA3FF VALVE, GATE, brass, 3", threaded fem/fem 1

WNECGACR4M3F COUPLING, GALVA, REDUCER, 4"-3",ND100/ND80,threaded male/fem 1

WNECGACR3M2F COUPLING, GALVA, REDUCER, 3"-2", thread male/fem. 1

WNECSTCC3SM COUPLING, 'Storz', 3", threaded male 2

WNECGAEE3M3M COUPLING, GALVA, ELBOW, 3", 90°, thr.male/male, small radius 2

WNECGANN3M3M COUPLING, GALVA, NIPPLE, 3", threaded male/male 1

WNECSTCC3SF COUPLING, 'Storz', 3", threaded female 1

WNECGANN2M2M COUPLING, GALVA, NIPPLE, 2", threaded male/male 1

WNECGANN4M4M COUPLING, GALVA, NIPPLE, 4", threaded male/male 1

WNEHPVSP1/215 HOSE, PVC flexible reinforced, clear, 1/2"x15m 1

WNECGACR3M1F COUPLING, GALVA, REDUCER, 3"-1", ND80/ND25, thread male/fem 1

WNECBRCA1M1/2T COUPLING, BRASS, ADAPTOR, threaded male 1" to hose tail 1/2" 1

WNECGATT3FFF COUPLING, GALVA, TEE, 3", ND80, threaded fem/fem/fem 1

WNECGANN3M3M COUPLING, GALVA, NIPPLE, 3", threaded male/male 2

WNEABACL015 BAND CLIP, high pressure, 15-20mm 2

WNEVBRGA1FF VALVE, GATE, brass, 1", threaded fem/fem 1

WNECGANN1MM COUPLING, GALVA, NIPPLE, 1", threaded male/male 1 KWATTOOLPU01 KIT, TOOL + ENG.OIL, for pumping set up, wat. and sanit. ERU ETOOKEYS200 PIPE WRENCH, strap nylon, max. 200 mm opening 2

ETOOKEYS6 PIPE WRENCH, adjustable grip head, max. 140 mm opening 1

ETOOSAWSM150 HACKSAW, JUNIOR, for 150mm blades with 1 blade 1

ETOOSAWSM150B BLADE, for junior hacksaw, 150mm long, 10 teeth/cm 10

ETOOWRENV28O SPANNER, adjustable, max. 28mm opening 1

ETOOSCDRF65 SCREWDRIVER, flat blade of 6.5 x 150mm 1

ETOOWREN7/16 SPANNER, SET, combinaison, 7/16 - 3/4", A.F. 1

ETOOWREN1/4 SPANNER, combinaison, 1/4" 1

ETOOKEYSH7/32 KEY, hexagonal male "Allen", 7/32" 1

ETOOKEYSH3/16 KEY, hexagonal male "Allen", 3/16" 1

Page 109: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 429

ETOOKEYSH3M KEY, hexagonal male "Allen", 3mm 1

ETOOPLIEUN20 PLIER universal 180 mm length, plastic sheats 1

ETOOMEAS19BL FEELER GAUGE, set of 19 blades from 0.04 to 1 mm, metric 1

ETOOLUBRC35 OIL CAN, 350ml, with pump and rigid oulet, aluminium body 1

WNECSTHO2-3 (coupling Storz) HOOK SPANNER, 2"-3" 1

WTOOSPANSWIV SPANNER, ring type, for swivel fittings 1

ETOOHAMMWOMA WOODEN MALLET 1

TVECLUBRO26 OIL, ENGINE, diesel/petrol, 15W40, jerrican 5lt 10

TVECJCANM20 JERRYCAN, 20 l, metallic 1

TVECMVACBT20 FUNNEL, dia. 200 mm, bended + metallic filter 1

TVECMVACBT19 FUNNEL, dia. 80 mm, plastic 1 KWATPUMCERU2 KIT, MOTOR PUMP, diesel, lightweight, + PIPES WPUCESRW001 PUMP,END-SUCTION, diesel, Self-Priming Lightweight,2"/3.3kW 1

WNEHPVSP305T HOSE, PVC flexible spiralled, 2 con. thread. 3" mal/fem, 5m 1

WNEHSBFL315T HOSE, SBR, FLAT, delivery, 3", +2 threa. coup. male/fem, 15m 1

KWATPUMCSP09 KIT, SPARE PART, pump Lombardini Quiete 15LD225, 2000h 1 KWATTANKP05T KIT, WATERTANK, flexible pillow, 5m3, transport/storage WWAKFLPT05T WATERTANK, flexible pillow, PVC, transport/storage, 5 m3 1

WNEVBRGA3FF VALVE, GATE, brass, 3", threaded fem/fem 2

WNEHPVSP315T HOSE, PVC flexible spiralled, 2 con. thread. 3" mal/fem, 15m 1

WNECGATT3FFF COUPLING, GALVA, TEE, 3", ND80, threaded fem/fem/fem 1

WNECGANN3M3M COUPLING, GALVA, NIPPLE, 3", threaded male/male 3

WWAKFLPT05GS (pillow tank 5m3) GROUND SHEET 1

WWAKFLPT05TH (pillow tank 5m3) HARNESS, for trucking 1

WNECSTCC3SM COUPLING, 'Storz', 3", threaded male 1

WNECSTCC3SF COUPLING, 'Storz', 3", threaded female 1 KWATRAMP06AP KIT, 1 TAPSTAND + PIPEWORK, water and sanit. ERU KWATRAMP06A KIT, WATER TAP STAND, 6 automatic taps 1

WNEPPESR32 PIPE, MDPE polyethylene, d.ext: 32mm, NP10, coil, per meter 12

WNECCOCR32C1M COUPLING, COMPRESSION, thread. male 1" to pipe d.ext 32mm 4

WNECGATT2FF1F COUPLING, GALVA, TEE, reduced, 2" - 1", thread fem/fem/fem 1

WNECCOCR2M63 COUPLING, COMPRESSION, thread. male 2" to pipe d.ext:63mm 2

WTOOSEALTEFL SEAL TAPE, 'Teflon', for water connectors, roll 12mm x 12m 1

WNECGACP2M COUPLING, GALVA, PLUG, 2", threaded male 1

WNEVBRGA1FF VALVE, GATE, brass, 1", threaded fem/fem 1

WNECCOCC32CC1 COUPLING, COMPRESSION, socket, for MDPE hose d. ext: 32 1

Page 110: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

430 Water and Sanitation

WNECCOTT32CCC COUPLING, COMPRESSION, Tee, for pipe d. ext: 32mm 1

WNECGACR3M1F COUPLING, GALVA, REDUCER, 3"-1", ND80/ND25, thread male/fem 1

WNECGACR3F1F COUPLING, GALVA, REDUCER, 3"-1", ND80/ND25, threaded fem/fem 1 KWATTANKRTO1 KIT, TOOLS, for rigid corrugated water tanks ETOOKEYSFJ110 HANDLE, BRACE, for 3/8" square drive sockets 1

ETOOSOCK12P17J SOCKET 17 mm 3/8" 12 points 2

ETOOKEYSF40.17 SPANNER, COMBINATION, 17 mm ring, 15° angled, open and ring end 2

ETOOKEYSF40.24 SPANNER, COMBINATION, 24 mm ring, 15° angled, open and ring end 2

ETOOSCDRF6.5X20 SCREWDRIVER, flat head 6,5x200mm 2

ETOOFILEHRC200 FILE, HALF-ROUND, coarse, 200mm long 1

ETOOFILEN160 FILE, NEEDLE, knife cut, 160mm long 1

ETOOCUTTH HACKSAW, builder type, with 1 blade, L: 300mm 1

ETOOCUTTHB (hacksaw) BLADE, HSS, 10 teeth / cm, 300mm 3

ETOOCUTTL5 CUTTER, retractable, interchangeable blade, 150mm, alu. body 1

ETOOCUTTL5B (cutter alu 150mm) BLADE, normal cut 5

ETOOKEYS200 PIPE WRENCH, strap nylon, max. 200 mm opening 2

ETOOMEASLS40 LEVEL aluminium 400 mm standard 1

ETOOMEASLL01 LEVEL, line level 1

ETOOMEASLP18 LINE PINS with 18m of line, PAIR 1

ETOOSCISSTD1 SCISSORS, std, 105mm, one pair 1

APROGLOVHDL10 GLOVES, protection, heavy duty leather, size 10 3

ETOOWRENV28O SPANNER, adjustable, max. 28mm opening 2

ETOOKEYSP2.5 WRENCH for PIPE open.65mm, lenght 18" 450mm with teeth 1

ETOOSAWSM150 HACKSAW, JUNIOR, for 150mm blades with 1 blade 1

ETOOSAWSM150B BLADE, for junior hacksaw, 150mm long, 10 teeth/cm 3

ETOOCUTTSF300 PLANE, SURFORM, 300mm 1

ETOOCUTTSF300B (surform 300mm) BLADE 2

ETOOKEYS6 PIPE WRENCH, adjustable grip head, max. 140 mm opening 1

WNECSTHO2-3 (coupling Storz) HOOK SPANNER, 2"-3" 4

ETOOLADD4500 LADDER, aluminium extendable, 4.5m 1

ETOOKEYSH6L KEY, hexagonal male, "Allen" 6mm, long shank 6

WTOOSPANSWIV SPANNER, ring type, for swivel fittings 1 KWATTANKR10 KIT, WATER TANK, 10 m3, rigid, corrugated Pack 1: STEEL KIT WWAKRTOXIS03 IRON SHEET, corrugated, for rigid tank 10m3 15

WWAKRTOXIS04 IRON SHEET, corrugated, for rigid tank 10m3, + outlets 3 Pack 2: LINER KIT WWAKRTOXCA12 SPLIT CAPPING, PVC, d:12mm, per metre length 8

WWAKRTOXCA25 SPLIT CAPPING, PVC, d:25mm, per metre length 8

Page 111: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 431

EHDWCLIP25 CLIP, spring clips, 25mm 25

EHDWBOLTGR01 BOLT, galva, round head with slot drive, d:10mm, L:20mm 410

EHDWNUTSG10- NUT, galva, hexagonal, d:10mm, size: 17mm 410

EHDWWASHF10 WASHER, galva, flat, d:10mm 410

ETOOPODG01 PODGER, spike to align iron sheet bolt holes 1

WNEVBRGA3FF VALVE, GATE, brass, 3", tread fem/fem 1

APACSCOT50RB TAPE, adhesive, canvas reinforced, 55mm, roll 50m, black 1

WNECIRFL3ASS CONNECTOR, FLANGE ASSEMBLY, 3”, complete set 2 Each including: WNECIRFL3M90 CONNECTOR, 3”, pipe L:90mm threaded male, flanged, 4 x M10 1

WNECIRFL3M FLANGE, counterplate, 3”, 4 plain holes d: 10mm 1

WNECIRFL3G (3" flange) GASKET, 2mm thick rubber, 4 holes 10mm 2

EHDWBOLTS161 STUD, galva, d:16mm, L: 100mm 4

EHDWNUTSG16- NUT, galva, hexagonal, d: 16mm, size: 24mm 8

EHDWWASHF16 WASHER, galva, flat, d:16mm 8

WWAKRTOXL10 LINING, 10m3, EPDM reinforced synth. rubber, thick: 1.25mm 1 Including: KWATREPAEPLI REPAIR KIT, for rigid water tank EPDM rubber liners 1

WWAKREPAEPSH EPDM MATERIAL SPARE, 1 x 1m 1

WWAKREPAEPTA ADHESIVE TAPE, to repair EPDM liners, 50mm x 10m 1

WTOOSEALTEFL SEAL TAPE, 'Teflon', for water connectors, roll 12mm x 12m 1

WNEABACL077 BAND CLIP, high pressure, 77-95mm 1

WNECBRCA3F3T COUPLING, BRASS, ADAPTOR, 2 pces, thr. fem. 3"/hose tail 3" 1

WWAKRTOXGUIDE MANUAL, Oxfam Water Storage Pack, in a plastic bag 1 Pack 3: ROOF KIT WWAKRTOXRO10 ROOF, 10 m3 rigid tank, PVC coated polyester, + eyelets 1

WWAKRTOXROS1 ROOF SUPPORT ASSEMBLY, for 10m3 rigid tank 1

HSHEROPE06P ROPE, polypropylene, black, d:6mm, per metre length 100

EHDWVHDWEY10 EYE NUT, M10 12

KWATREPAF01 KIT, REPAIR, for PVC flexible reinforced material 1 KWATNEACAS01 KIT, ADAPTORS AND SPARES, water and sanit. ERU WNEVBRGA3FF VALVE, GATE, brass, 3", threaded fem/fem 2

WNECGANN3M3M COUPLING, GALVA, NIPPLE, 3", threaded male/male 4

WNECSTCR3-2 COUPLING, 'Storz', REDUCER, 3"-2" 2

WNECGATT3FFF COUPLING, GALVA, TEE, 3", ND80, threaded fem/fem/fem 2

WNECSTCC3SM COUPLING, 'Storz', 3", threaded male 12

WNECSTCC3SF COUPLING, 'Storz', 3", threaded female 12

WNECGATT2FFF COUPLING, GALVA, TEE, 2", threaded fem/fem/fem 1

WNECCOCR2M63 COUPLING, COMPRESSION, thread. male 2" to pipe d.ext:63mm 5

WMEAPRES10 GAUGE, PRESSURE, for water, 10 bar, + adapt. thread male 1" 1

WNECGATT3FF1F COUPLING, GALVA, TEE, reduced, 3"-1", thread fem/fem/fem 1

WNEVBRGAV1MF VALVE, VENT, for pressure gauge, 1" thred mal/fem 1

Page 112: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

432 Water and Sanitation

WNECGANN3M3M COUPLING, GALVA, NIPPLE, 3", threaded male/male 2

WMEAFLOW2F FLOWMETER, 2", threaded female 1

WNEABACL077 BAND CLIP, high pressure, 77-95mm 8

WNECGATT3FFF COUPLING, GALVA, TEE, 3", ND80, threaded fem/fem/fem 2

WNECCOCR32C1M COUPLING, COMPRESSION, thread. male 1" to pipe d.ext 32mm 3

WNECGACR3F2M COUPLING, GALVA, REDUCER, 3"-2", threaded fem/male 3

WNECGACR3M2F COUPLING, GALVA, REDUCER, 3"-2", thred male/fem. 3

WNECCOCC63 COUPLING, COMPRESSION, socket, for MDPE hose d. ext: 63mm 5

WNEVBRGA1FF VALVE, GATE, brass, 1", threaded fem/fem 1

WNECGATT3FF1F COUPLING, GALVA, TEE, reduced, 3"-1", thread fem/fem/fem 1

WNEVBRGA3FF VALVE, GATE, brass, 3", threaded fem/fem 1

WNECCOCR3M63 COUPLING, COMPRESSION, thread. male 3" to pipe d.ext:63mm 2

KWATREPASBFL KIT, REPAIR, for SBR layflat hose pipe 2

WNECBRCA3F3T COUPLING, BRASS, ADAPTOR, 2 pces, thr. fem. 3"/hose tail 3" 4

WNECBRCA3M3T COUPLING, BRASS, ADAPTOR, thread. male 3" to hosetail 3" 4

WNECBRCA3G (hosetail coupling 3") GASKET WASHER 10

WTOOSEALHE HEMP, for plumbing, 500g 5 Alternative to KIT, WATER TANK, 10 m3, rigid, corrugated: KWATTANKP10 KIT, WATERTANK, flexible pillow, 10m3, storage WWAKFLPT10 WATERTANK, flexible pillow, PVC, storage, 10 m3 1

WNEVBRGA3FF VALVE, GATE, brass, 3", threaded fem/fem 3

WNEHPVSP330T HOSE, PVC flexible spiralled, 2 con. thread. 3" mal/fem, 30m 1

WNECGATT3FFF COUPLING, GALVA, TEE, 3", ND80, threaded fem/fem/fem 1

WNECGANN3M3M COUPLING, GALVA, NIPPLE, 3", threaded male/male 3

WWAKFLPT10GS (pillow tank 10m3) GROUND SHEET 1

Page 113: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 433

Emergency Response Unit WatSan Specialised Wat-San module

Code Description Ind. price Ship. weight Ship. Vol. ERU, Water and Sanitation, Specialised

Wat-San CHF 650’000 15’000kg 70m³

Cold chain: No Dangerous: Yes. Chemicals Regulated: Yes. IATA packages

General information The complete Water and Sanitation ERU is composed of 4 modules:

- ERU, Water and Sanitation, Treatment and Supply module

- ERU, Water and Sanitation, water Distribution and Trucking

- ERU, Water and Sanitation, Specialised Wat-San

- ERU, Water and Sanitation, Mass Sanitation

The purpose of the Specialised Wat-San module is to provide safe drinking water and basic sanitation facilities and systems for health installations such as hospitals, feeding centres, dispensaries, first aid posts and staff quarters, as well as for smaller population figures of up to 15,000 people in emergency situations.

The module has a principle treatment and distribution capacity of 120,000 litres per day of safe drinking water in line with WHO/SPHERE quality standards and a storage capacity of max. 200,000 litres per day and provides basic sanitation systems for up to 15,000 people.

The module carries out the mechanical and chemical treatment of raw water and ensures the production of approximately 120,000 litres of safe drinking water daily and puts basic sanitation systems (latrines, vector control measures, etc.) in place.

Indicative staffing patterns

- 1 engineer (teamleader)

- 3 plumbers/general technicians

- 1 electrician and 1 logistician (optional)

2 types of treatment units are available:

- Equipment Filter unit type SETA 3000 (e.g. Spanish Red Cross)

- Equipment Filter unit type Berkefeld (e.g. Austrian, German Red Cross)

Page 114: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

434 Water and Sanitation

Specifications As per the individual specifications of each items. Refer to respective item sheets.

Module content list Equipment Filter unit type SETA 3000 (e.g. Spanish Red Cross) Description Qty

tapstand 20 storage tank (bladder 5m³/10m³ or other type) 150m³ pressure hose C 500m fitting/adapter kit 1 laboratory kit 1 tools kit 1 kit personal & team equipment 1 4WD car (federation standard) 1 generator 1 electric/lightning kit 1 tent 5 set chemicals necess. for 1 month operation 1 Filtration plant on trailer, complete (generator etc.) 5 Centrifugal pump Honda WH40D 5 spare parts kit for pump 5 suction hose 8m B with anti-reflux valve 5 floater 5 rope 5 submersible pump 5 pressure hose 25m C 5 raw water tanks 34m3 5 pressure hose 25m B 20 set Storz BC adapter 5 set Storz C Guillemen adapter 10 roll of fencing 5 Kaercher water pressure dispenser 5 fuel jerry can 20 ltrs. 5 Roll of fencing (50m) 10 Storz coupling wrenches 20 Motor oil 20W/40 5

Page 115: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 435

Bladder 10m³ 5 Plastic sheet to protect Bladder 5 Gate valves 10 pressure hose 10m C 15 suction hose 6m C 10 T-piece with 2 valves C-CC 10 18" Stylson wrench 5 rolls of Teflon 20 Sacks of Alum (25 kg) 10 Bottles of chlorine/HTH (1 kg) 125 Equipment filter unit type Berkefeld (e.g. Austrian, German Red Cross) Description Qty

tapstand 20 storage tank (bladder 5m³/10m³ or other type) 150m³ pressure hose C 500m fitting/adapter kit 1 laboratory kit 1 tools kit 1 kit personal & team equipment 1 4WD car (federation standard) 1 generator 1 electric/lightning kit 1 tent 5 set chemicals necess. for 1 month operation 1 centrifugal pump (heavy duty B or C) 2 suction hose B,C 30 m water flow meter (B, C) 4 pressure hose B 250m Filter group TWA 6/10 2 Chlorine dosing plant TWA 6/10 2 Centrifugal pumps NP-4-D 6 Folding tanks 8.0/15.0 m3 (raw water) 8 Folding tank 8.0/15.0 m3 with roof (pure water) 2 Pressure hose 2Cx15.0m 4 Pressure hose 2Cx5.0m 14 Pressure hose 2Dx5.0m 2

Page 116: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

436 Water and Sanitation

Precoat hose 1Dx2.0m 2 Feeding hose 1Cx3.0m 2 Circulation hose 2Cx5.0m 4 Tank outflow pipe 8 Stirring paddle 2 Inflow pipe 2 Raw water collector 2 Suction hoses 2C-3.0m 32 Tapstand 2 Buckets 17 ltrs. 12 Outflow hose 1Cx3.0m 2 Fuel jerry can 20 ltrs. 6 Pouring spout for jerry can 2 Stirring paddle 500 lg. 6 Marking tape red/white 12 Float with chain 2 Strainer C 2 Protection basket for strainer C 2 Nylon rope 2 Distributor C-DCD 2 Tapping valve D 2 Set of tools 2 Pipe wrench 2“ 2 Coupling wrench BC 4 Test kit pH/chlorine 2 Hazardous goods case 2 Fine dust filter mask 2 Apron 2 Safety glasses 2 Eye rinsing bottle 2 Safety gloves 8 Filter candle 2 Seal TWA-3/6/10 4 Sealing ring C-DS 10 Hose clip 50-70-13 10 Rigid coupling, C-1 1/2“i 2 Blind coupling C 2 Hose coupling C 2

Page 117: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 437

Rigid coupling, C-2“i 2 Spare glass flow meter GAW 2 Manometer 0-6 bar 2 Funnel 2 Hand lever, ball valve, 1 1/2 a. 2" 2 Hand lever, ball valve, 3/4 a. 3/8" 2 Hose shut-off valve 2xC 2 Repair set folding tank 2 Measuring beaker 2 Flow meter for chlorine dosator 2 Spare glass with ball for flow meter 2 O-ring 22x6 2 Sealing ring d200 2 Displacement bubble for dosator 2 Coupling, adapter C-D 2 Float (cubitainer) 10 End support 45 8 Exhaust gas hose 6 Motor oil SAE 15W40 2 Teflon tape reel 4 Bottles of chlorine/HTH (2.5 kg) 22 Bags of activated carbon (2.5 kg) 30 Bags of lime hydrate (1.5 kg) 24 Bottles of ferric chloride (2.1 kg) 30 Bags of Berkesil KE (1.0 kg) 100 Equipment Sanitation Description Qty

Hoes (farmtype, carbon steel blade) 10 Shovels (round point, carbon steel blade) 10 Spade (square point, carbon steel blade) 10 Pick axes (carbon steel) 10 Axes (handle length 660 mm) 5 Saws (forest type, length 750 mm) 5 Hammers (carpenter) 5 Backpack sprayer (manual, 15-20 ltr, 5 bar) 3 Backpack sprayer (motorised, medium size) 1

Page 118: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

438 Water and Sanitation

Insecticide (Deltametrine) 200L Chlorine/HTH 25kg Overalls (cotton, size L & XL) 30 Safety goggles 30 Heavy duty working gloves, pair 30 Heavy duty rubber gloves, pair 30 Felt face mask 30 Rubber boots (size 40-46), pair 30 Plastic drums (top open, with tap at bottom) 4 Wash basin (plastic, 40 litres) 10 Soap (100 g) 200 Buckets 10-20 l (5 plastic, 5 steel) 10 Measuring jugs (1 litre graded) 5 scale (graded from100g to kg´s) 1 scale (graded up to 10 kg) 1 Rope (8 mm, syntethic nylon) 200m Rolls of String 3mm (100m, hemp) 5 Squating plates 50 Wheelbarrow (85 l, pneumatic wheel) 3 Rolls of plastic sheeting, Monarflex 5 Bodybags with zip 30 Latrine SanPlat Mould Box 1 Cobra Rock drill 1

Page 119: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 439

Emergency Response Unit WatSan Mass Sanitation module

Code Description Ind. price Ship. weight Ship. Vol. ERU, Sanitation, Mass Sanitation CHF 40’000 4.7MT 25m³ Cold chain: No Dangerous: Yes - Chemicals Regulated: Yes - IATA

General information The complete Water and Sanitation ERU is composed of 4 modules:

- ERU, Water and Sanitation, Treatment and Supply module

- ERU, Water and Sanitation, Water Distribution and Trucking

- ERU, Water and Sanitation, Specialised Wat-San

- ERU, Water and Sanitation, Mass Sanitation

The purpose of the Mass Sanitation Module is to provide basic sanitation facilities for larger populations in emergency situations and to initiate essential environmental health intervention.

The module has the capacity to provide a maximum of 40,000 beneficiaries with basic sanitation facilities.

The principal tasks of the module are the planning and initiating latrine construction programmes, garbage collection and disposal programmes, burial of corpses, vector control and protection such as spraying of health installations, latrines, garbage disposal points, stagnant water ponds against flies, fleas, rats and mosquitoes.

Indicative staffing patterns, if deployed on its own and not together with the Treatment Supply Module:

- 1 chemical engineer or environmental health specialist (team leader)

- 2 environmental health technicians

Specifications As per the individual specifications of each items. Refer to respective item sheets.

Page 120: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

440 Water and Sanitation

Kit content list

Code description Qty APACPLASD200 DRUM, for water or fuel, plastic, with safety plug 2", 200L 4 APROBOOTR07 BOOTS, heavy duty plastic rubber, pair, size 7 6 APROBOOTR08 BOOTS, heavy duty plastic rubber, pair, size 8 8 APROBOOTR09 BOOTS, heavy duty plastic rubber, pair, size 9 10 APROBOOTR10 BOOTS, heavy duty plastic rubber, pair, size 10 8 APROBOOTR11 BOOTS, heavy duty plastic rubber, pair, size 11 8 APROGLOVHDL10 GLOVES, protection, heavy duty leather, size 10 30 APROGLOVHDR10 GLOVES, chemical protection, heavy duty rubber, size 10 30 APROGOOGPL GOOGLES, plastic, with rubber string, eyes protection 30 APROMASKD1 MASK, DUST PROTECTING, SIZE 1-5 50 APROOVERCO1 OVERALL, 100% cotton, white, 2 long zip, size L 6 APROOVERCO2 OVERALL, 100% cotton, white, 2 long zip, size XL 18 APROOVERCO3 OVERALL, 100% cotton, white, 2 long zip, size XXL 6 DASDCHLA7G25 CHLORE (HTH), 60 to 70%, granulates, 25 kg box, IATA 3 DCHPDELT2WP3 DELTAMETHRIN, 'K-OTHRINE', 2.5%, wettable powder, 33 g sach. 600 EBUICEMEWR1 WHEEL BARROW, 100 l, steel 20 EBUICEMEWR1S WHEELBARROW SPARE PARTS SET 2 ETOOCLEMHWC WATER (COLD) CLEANER, 220v,130 bar, 600 lt/h 1 ETOOHAMM204 HAMMER, carpenter type, nail claw, 800g 10 ETOOWSAW750 SAW, bow type, for wood, 750mm blade 10 HCONBUCKG10 BUCKET, metal, galvanised,10L 15

HCONBUCKP10 BUCKET plastic with lid, 10L 25 HCOOCOUSMJ1G- MEASURING JUG, 1 l, graduated, non rigid, transparent 5 HCOOPLASBAS40L BASIN, plastic, round, 40l 20 HHYGSOAP100G SOAP, toilet, 100 g bar 500 HSHEROPE01N STRING, polyamide, Nylon, d:1 mm, per meter length 1600 HSHEROPE06P ROPE, POLYPROPYLENE, diam. 6 mm, twisted 800 HSHETARPW10X4/6 TARPAULINS, woven plastic sheeting 4 x 60m white/white, roll 20 RAGRTOOLAXE2 PICK-AXE, with handle 50 RAGRTOOLAXE3 AXE, 2.5kg, with safety handle 10 RAGRTOOLHOE3 HOE, with long handle, large type 50 RAGRTOOLSHOV3 SPADE SHOVEL, square point, D handle 50 RAGRTOOLSHOV2 SHOVEL, mason type, with long handle 100 WSANBODBUSH BODY BAG, U shaped zip bag, white opaq., 2.2x0.8m, 200micron 40

WSANSPRA20 SPRAYER, manual, back pack, 20l 10 WSANSPRA20M SPRAYER, motorised, backback, 20l 1 WSANSQPL001 SQUATTING PLATES,polypropylene,+ drop-hole cover 100 WSANSQPL002 MOLD, for making latrine slabs, SanPlat type 2 XLABSCALK11 KITCHEN SCALE, weighing 1 kg, accuracy 10g 1 XLABSCALK110 KITCHEN SCALE, weighing 10 kg, accuracy 100g 1 ETOOPOWEROCK ROCK DRILL, Cobra, petrol engine, + scissors set 1

Page 121: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 441

Typical generator fault finding procedure Listed below are typical faults which may occur together with the action required to remedy the fault.

ENGINE

Fault Possible cause Engine will not turn a) Battery discharged. Loose or incorrect cable connections. Electrical

fault in starting circuit. b) Faulty starter motor. c) Starter pinion will not engage on flywheel starter ring.

Action a) Check voltage.

- Voltage at battery terminals. If no voltage change or put on charge.

- Voltage at starter motor terminals.

b) If voltage present: - Check all connections.

- Change starter motor.

c) Turn engine by the tools provided and repeat attempt to start. Replace starter motor if fault remains.

Fault Possible cause Engine will not fire a) No fuel reaching injectors. Fuel supply line blocked.

b) Air lock in fuel line. c) Fuel filters choked. d) Water in fuel. e) Air cleaners choked. f) Fuel pump timing out. g) Lift pump faulty.

Action a) Operate excess fuel device. b) Check that fuel tap is 'on' and adequate amount/head of fuel is in tank. c) Bleed fuel system. d) Change filter elements on engine. Drain contaminated fuel. Empty fuel filter bowls and change

elements. e) Clean air cleaners. f) Reset timing. g) Change lift pump.

Page 122: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

442 Water and Sanitation

Fault Possible cause Engine fires but fails to pick up speed

a) Fuel supply system faulty. b) Air cleaner choked. c) Faulty lift pump. d) Faulty air injectors.

Action a) Check all pipe joints. Bleed fuel system. b) Clean air cleaners. c) Change lift pump. d) Change injector(s).

Fault Possible cause Engine misfires a) Air lock in fuel line.

b) Fractured injector feed pipe. Faulty injector. c) Faulty injection pump. d) Tappet clearances incorrect.

Action a) Bleed fuel system. Replace pipe. b) Loosen feed pipe to each injector in turn and note any change in engine response. c) Change injection pump. d) Check and readjust tappet clearance accordingly.

Fault Possible cause Low power output a) Inadequate fuel pressure.

b) Air filters choked. c) Fuel injection pump timing incorrect. d) Faulty injection. e) Tappet clearance inadequate. f) Faulty turbocharger. g) Inlet manifold and/or cylinder head joints leaking

Action a) Check over complete fuel supply system as previously laid down. b) Clean air filters. c) Reset timing. d) Change injector(s). e) Adjust tappets. f) Replace turbocharger. g) Renew gasket or joint packings as necessary.

Page 123: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 443

Fault Possible cause Low oil pressure (Sudden pressure drop as opposed to progressive drop due to worn bearings)

a) Oil level too low. b) Oil pressure gauge faulty. c) Oil filters choked. d) Relief valve faulty.

Action

a) Check for leaks and fill to level indicated on dipstick. b) Fit an identical replacement gauge. c) Change filter elements. d) Examine and clean pressure relief valve.

Fault Possible cause Overheating a) High oil temperature.

b) No coolant in engine. c) Coolant system polluted. d) Blocked air passages in radiator matrix. e) Fan belt tension incorrect. f) Thermostat fault. g) Fuel injection pump timing out. h) Low oil level.

Action a) Check out as detailed in 'overheating' below. b) Check for leaks and refill (ensure correct percentage of anti-freeze is also added if necessary). c) Drain, flush out and refill. d) Carefully clean all air passages. e) Adjust tension. f) Fit an identical replacement thermostat. g) Reset timing. h) Check for leaks &fill to level indicated on dipstick.

Fault Possible cause Inadequate fuel a) Fuel supply system faulty.

b) Faulty fuel lift pump. c) Fuel relief valve faulty. d) Choked fuel filters.

Action a) Check all pipe joints for leaks. b) Replace with identical unit. c) Examine and clean valve. d) Change filter elements.

Page 124: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

444 Water and Sanitation

Fault Possible cause Exhaust emits black smoke Excess fuel being used. Action Change pump if maximum fuel stop seal has been broken.

Fault Possible cause Machine becomes over-heated

a) Cooling air inlet blocked or obstructed. b) Cooling air discharge blocked or obstructed. c) Rotor bearings running hot. d) Machine overloaded. e) Short circuit between windings and/or windings to frame.

Action a) Clean screen protection and remove any obstruction preventing air entering the air inlet. b) Proceed as for air inlet above. c) Too much or too little grease. Remove bearing from machine and check conditions. Repack with

correct grade and quantity of grease before reassembling. d) Check that the electrical overload equipment and circuit breaker are working satisfactorily. e) Replace windings.

CONTROL EQUIPMENT The faults liable to occur in this equipment will depend upon the design of the control scheme supplied. It is only possible to give general recommendations regarding fault findings on this equipment.

Fault Possible cause Circuit fuses blowing a) Incorrect rating of fuse used.

b) Short circuit between panel wires and/or between wires and frame. Action a) Check circuit rating and fit new fuse of the recommended rating. b) From circuit diagram check wiring of components. Rewire or replace components found faulty.

Fault Possible cause Circuit operating satisfac-torily only intermittently

Faulty or out of adjustment relay or auxiliary contacts.

Action Replace and/or readjust auxiliary and clean where necessary.

Page 125: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 445

Fault Possible cause Excessive 50 Hz buzz or hum

Dirty, rusty or badly aligned pole faces

Action Clean, de-rust with fine emery paper and readjust. Leave a minute film of oil on the parts concerned to retard formation of rust.

Fault Possible cause Overheating cable ends and terminations

Loose connections.

Action Tighten all connections, making sure all dangerous voltages have first been switched off and cannot be switched on again whilst work is in progress. Ensure all terminations subject to heat/load cycling i.e. the main cabling terminations are suitably lock nutted.

ALTERNATOR In all instances it is recommended that for specific fault finding instructions the manufacturers handbook be referred to as designs vary in detail from manufacturer to manufacturer. The details given below are for general guidance only.

Fault Possible cause No output voltage a) Engine speed too low.

b) Loose terminals. c) No excitation and/or loss of residual magnetism. d) Open circuit in windings. e) Faulty automatic voltage regulator (AVR). f) Faulty diode in main rectifier assembly on the rotor. g) Open circuit of the gain and/or range control on the AVR. h) Hand operated voltage trimmer open circuit (if fitted).

Action a) Check and set up correctly. b) Check over and tighten all terminals. c) Re-excite by flashing in accordance with manufacturers handbook. d) Check for continuity in accordance with manufacturers handbook: renew if required. e) Remove leads at voltage control unit terminal block, run set up to speed and flash excitor in

accordance with the manufacturer's handbook. If the voltage appears then the AVR is faulty and should be tested out in accordance with the instructions given for testing A.V.R.'s.

Page 126: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

446 Water and Sanitation

f) Remove and test with ohmmeter; the forward resistance should be less than 1000 ohms and the

reverse resistance greater than 100K ohms. Replace if necessary. N.B. When this fault occurs it is likely that more than one and possibly all the diodes may need replacing.

g) Check for continuity.

Fault Possible cause Output voltage unstable Incorrect setting of gain control. Action Adjust slowly until a stable voltage is obtained.

Fault Possible cause Output voltage incorrect Voltage set up incorrectly on band trimmer or choke tappings. Action Adjust accordingly.

Fault Possible cause Output voltage too high and cannot be reduced on controls

Automatic voltage regulator faulty.

Action Remove AVR and make recommended tests. Replace if found necessary.

Page 127: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 447

Technical data for pumping and generating sets

Failure to prime or pump

Derating

Engine derating At altitudes higher than 100m Above Mean Sea Level (AMSL), the reduction of atmospheric

pressure induces a reduction of the performance of all combustion engines. Also the ambient temperature will affect the engine performance in the same way.

Page 128: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

448 Water and Sanitation

- This has an impact on the operation of all type of combustion engine powered equipment. The standard output of these equipments must be corrected according to the altitude and ambient temperature of use.

Example: For a naturally aspirated (not turbo charged) engine, at 1500m AMSL with an ambient temperature of 40°C it is necessary to derate by: - 18.7 % for altitude and by - 6% for temperature. Total derating is - 24.7%.

- In this example, a 3 cylinder diesel generator engine rated for 14.2 kW output at normal conditions of pressure & temperature (NPT), will deliver 10.6 kW only.

The deration for a turbo-charged engine is much less (around 7% for altitude for the same example conditions given above) and are not available or suitable for smaller power.

Rating standards According to BS5514 / ISO3046 / IN6271, deration for naturally aspirated (not turbo) diesel

engines are:

- Altitude: 4% for every 300m (1000 ft.) higher than 100m (330 ft.) above sea level.

- Temperature: 2.0% for every 5°C (10°F) above 25°C (77°F).

Note: Manufacturer’s output ratings apply only to fully run-in engines without power absorbing accessories such as fans, alternators, etc.

Pump suction derating Not always widely appreciated is the need to “derate ” the suction capability of a pump according to

the altitude of operation. In the chart below one can see the Variation of Atmospheric Pressure with Altitude.

At sea level the potential maximum (theoretical) lift is approximately 10.3 m. It is safer to assume the Low Barometer condition of 10 m. From this figure must also be deducted the suction line dynamic losses and the pump Net Positive Suction Head or NPSH (briefly this is the energy required to get the water into the pump itself) plus a minimum allowance of 0.5m

In consequence the maximum practical static lift is generally set at 7.5m (25 ft). It can be seen that, for example, at 1500 m AMSL that the Low Barometer atmospheric pressure is reduced to 8.25m so that the same pump will be capable of lifting almost 1.8m less than at sea level.

Page 129: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 449

Head loss in PE and PVC pipes When calculating the total head of a pumping set up, one should include the loss of head due to the

friction inside the pipes.

- This fluctuates with the diameter and the length of pipe involved, the pipe material, the flow and the speed of the water in the pipe.

The diagram below gives the values for PVC and PE pipes, rigid or flexible, (excluding the lay flat hoses in which the loss is higher)

Page 130: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 451

Installation of pumps and generating sets The information contained in the following pages is to assist you in the installation of engine driven pumps and generators .We would, however, point out that because the range of equipment can extend from 1 kVA to over 1000 kVA it has been necessary to generalise in many instances. Should you be in doubt, technical support at HQ can provide expertise in the installation of your pump or generating set. Please feel free to call on this service, as errors in design can prove very costly at the end of the installation. Servicing and fault finding must always be carried out in conjunction with the pump, engine and alternator manufacturers recommendations. A copy of their service manual together with copies of all circuit diagrams are usually supplied.

Typical installation generator set

Page 131: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

452 Water and Sanitation

General information

Nearly all generating sets and pumping sets are capable of running on any outdoor or indoor solid foundations. Where adverse weather is likely it is recommended the unit is supplied complete with canopy or similar method of covering.

For fixed installations it is advised to take into consideration the following points:

- Foundations: The room and floor should be of solid construction with a concrete floor and have adequate space for the servicing of the equipment. The foundations should also be flat and level. See also next chapter.

- Trenches: Trenches should be allowed in the floor for both fuel pipe work and cables. They should never be run in the same trench. With cable trenches you must always take into account the bend radius of the cable when determining the depth of the trench.

- Ventilation: For water-cooled or air cooled engines the room should have adequate ventilation with either louvered inlet and outlets or extractor fans. The importance of cooling air inlets and hot air outlets cannot be over stressed.

- Fuel Supply: It is most important that sufficient fuel and easy handling facilities are provided with the generating set. On unattended sites, it is recommended to provide an automatic 'top up' system.

- Exhaust System: The exhaust must always be taken to the outside of the building and care should be taken to ensure that the fumes or noise do not cause inconvenience to others.

- Noise attenuation: Advice on attenuation can be provided so as to reduce the noise level in degrees to a level which is virtually inaudible outside the building.

- Fire precautions and Warning notices: It is strongly recommended to provide fire protection for all types of fire likely to occur in the engine room together with warning notices showing the dangerous parts of the machinery and control panel. Please consult with your fire officer as to the best methods of fire control.

- Switchgear: Your control panel should be placed with easy access and the installation and repair should only be attempted by competent electricians.

- Commissioning: Technical support group can provide a pre-commissioning check of your installation and can fully commission the plant if you require.

Foundations For existing concrete foundations if in doubt as to the load carrying capabilities it is advisable to consult a structural engineer. He/she will require the weight and dimensions of the unit showing the fixing points and also the type of equipment so as to check that all vibrations produced by the set running will be absorbed. For new foundations the following information will be required when calculating the size and depth

of the base:

- Total size of the unit (add 300mm to length and width for the foundations)

- Total net weight

- Type of mounting provided

Page 132: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 453

- To calculate the necessary foundation depth the following formula should be used:

Depth (m) = W . 2402.8 x B x L

where: W =Total net weight of set (kg) B =Foundation width (m) L =Foundation length (m)

- This is with a suggested concrete mixture of 1 part cement, 2 parts sand, and 3 parts aggregate. The foundations should be reinforced with steel reinforcing bars.

- If anti-vibration mounts are not used, add 25% to the weight of the set to allow for the transmission of the vibration.

Anti vibration mountings These are two types of mounts, one with rubber isolators and the other with adjustable springs.

- The mounts are delivered with the sets in accordance with the manufacturer's recommendations.

Fuel tanks You will have received with your set either a set mounted or separate fuel tank. The set mounted

tank will be already connected to the engine and no other pipe work between the engine and fuel tank is required.

- If a separate tank is provided it should be positioned within easy reach of the engine fuel pump and should be either wall or floor mounted.

Engines without fuel lift pumps require the fuel tank to be at least 0.6 metres above the fuel inlet on the engine.

- The fuel connections to the engine should always be flexible so as to absorb the vibration when the engine starts and is running. All other pipe work should be run in the size recommended in trenches or strapped and protected to either the floor or walls.

- Pipe work should not be galvanised as the zinc is attacked by diesel fuel.

- The outlet of the fuel tank should always be at least 25mm above the bottom of the tank and preferably at the opposite end to the drain plug. Both the outlets should have on/off valves.

Page 133: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

454 Water and Sanitation

A suitable vent connection must be provided in the top of the tank when an automatic fuel transfer system or hand pump is used for filling the tank.

- This should be at least the same diameter as the filling connection.

- It is recommended that a 3"diameter filling point be provided with a brass cap for hand filling in case of emergency.

The fuel leak off from the injectors should return to the top of the fuel tank with a separate conduit.

The fuel tank should either incorporate a sight glass or float operated fuel contents gauge.

Fuel storage in bulk When a large quantity of fuel is required it is necessary to provide a bulk storage tank.

- The tank should always be outside the building, either at ground level or burried. Check with local authority what is permitted.

If the main tank is mounted above the daily tank, fuel transfer can be by means of a simple on/off valve.

- In other cases it will be necessary to transfer the fuel by either a hand pump or by an electrical pump. An electrical pump can be controlled manually or, in an unattended station, automatically by means of float switches in the daily tank.

Provision should be made, especially on buried tanks, for a manhole to be incorporated so that the fuel tank can be easily cleaned.

The pipe work should incorporate on/off valves.

The filling connections should be at least 3" in diameter.

It is necessary to provide a method of fuel level indication for above ground installation. A float operated or visual fuel indicator is recommended.

- For buried tanks an electrically operated fuel level gauge should be provided.

Page 134: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 455

Exhaust system The engine exhaust system should be as short as possible so as to avoid back pressure which will

affect the performance of the engine.

The exhaust should come off the engine manifold with a short section of flexible pipe or bellows section to the exhaust silencer. By means of solid pipe and bends it is then taken to the outside atmosphere.

- All bends should be smooth and of large radius and should the pipe include more than two bends or be more than 6 m (20 ft.) long, then it is necessary to increase the diameter of the pipe to prevent excess back pressure. The engine manufacturer can give advice on the dimension of pipe required.

- The exhaust pipe should be supported preferably by hangers with vibration mountings at frequent points. The exhaust pipe should in no case be fixed rigidly or cemented on the wall. Try to avoid long vertical run, should it be required, install a drain plug at the bottom of the pipe to drain away any condensate which would have an adverse effect on the engine.

The exhaust gases should not terminate within the area used for engine cooling or aspiration, and where it passes through the room should be lagged to avoid excess heat transmission to the room and also to prevent injury to personnel.

Avoid combining two separate exhaust systems.

Discharging exhausts into existing flues may present incompatibilities.

There are various types of silencers available and your set will normally be supplied with a residential type silencer. Noise reduction can be reduced even further by the addition of another balanced silencer or by a specially designed silencer to meet your specific requirements.

If installed horizontally the silencer should slope away from the engine to prevent the condensate from entering the engine.

The exhaust run should always be kept well away from any wood or fuel pipe work.

Page 135: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

456 Water and Sanitation

Lubricating oils Details of the correct lubricating oil can be found in your engine operator handbook supplied with the generating or pumping set. Do not mix two different oils if they are not clearly indicated as “mixable”, as this will have a detrimental effect on your engine. Recommended oils are listed under codes TVECLUBR…

Electric start batteries Batteries should be placed as near as possible to the electric starter, preferably on a metal stand with a hardwood cover to prevent fuel, dust or metal objects falling on the terminals. The cover must be clear of the ventilation plugs. Remember to keep the terminals clean and greased at all times. As there are various types of batteries available it is recommended to refer to the instructions supplied with the unit as to the specific gravity and charging rates required. Unless otherwise specified all batteries are dispatched dry charged. Battery acid is not supplied, should be found locally. More information and choice of standard batteries see code EELEBATT…

Cooling of the equipment Air Cooled Engines

- Air cooled engines require a ducting outlet aperture at least twice as large as the engine outlet because the air is forced over the cylinder in the compressed state increasing the volume of air at the engine air outlet.

- The inlet should be half as large again as the engine outlet.

Page 136: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 457

Radiator Cooling

- Radiator cooling is the most common method of cooling diesel engines. It is most suitable to mount the engine radiator as close to the outside wall as possible with the air inlet on the opposite wall.

- The outlet should be approximately 25% larger than the matrix of the radiator with the inlet 50% greater.

- The inlet and outlet should be louvered to prevent rain entering the engine room.

- If it is not possible to mount the radiator within 75mm (3") of the wall a section of ductwork should be placed between the radiator and louvered to prevent the re-circulation of the hot air.

- If ductwork bends have to be used the widest radius possible must be incorporated to prevent back pressures building up.

Remote Radiator Cooling

- On installations where it is desirable to locate the radiator at some distance away from the generating set (i.e. the roof, outdoors or in another room), a remote radiator can be used.

- If the radiator is over 10m (30ft) away or above 6m (20ft) from the engine, then it will probably be necessary to incorporate a water circulating pump together with a break tank.

- In this case there must be the necessary precautions to prevent the engine room overheating by incorporating an extractor fan in the room. The air inlet should be increased in size by 50%.

Page 137: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

458 Water and Sanitation

Heat Exchanger Cooling

- Where an unlimited supply of water is available it may be advantageous to fit a heat exchange to the engine, as less air circulation and space is required in the engine room.

- A heat exchanger incorporates two cooling systems.

The primary circuit or engine cooling circulates throughout the closed engine passages and the primary tubes of the heat exchanger.

The secondary coolant (raw water) circulates through the heat exchanger secondary tubes and goes to waste, or is returned to the remote radiator.

- An auxiliary raw water pump is usually necessary to provide adequate raw water flow to the heat exchanger. The pump may be driven by the engine or by an electric motor.

Cooling Tower

- When limited water is available, the use of a cooling tower may be advantageous.

- The water is pumped through the heat exchanger and then up to the cooling tower where it is cooled by running over slats into a reservoir assisted by a motor driven fan. The water is then returned to the heat exchanger.

- It is usually necessary to provide a top up water supply as there is a 3% loss per hour through evaporation using this system.

Warning On all applications where external cooling methods are being used provision must be made in the case of an emergency for the total capacity of the water system to be retained in a bund wall, and must not be allowed to flood the room or come into contact with the electrical equipment.

Page 138: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 459

Anti Freeze Solutions To avoid freezing of the coolant it is essential that an anti freeze solution is used. The graph on Page 31.12 defines the strength of the ethylene glycol required for the lowest ambient temperatures. The coolant approved for use in diesel engines is a mixture of 50%inhibited ethylene glycol and 50% clean fresh water. Mixtures containing methanol or propylene glycol are not approved.

SELECTlON TABLE SPECIFIC GRAVITY CHART

Coolant mixture (% by volume) Protection down to

Anti-freeze Water Degree °C Degree °F 30 70 -15 15 50 50 -35 -31 60 40 -40 -40

Alternator Read carefully the alternator manufacturer's handbook supplied with the equipment. However the following points should be noted: Inspect the machine for any damage. Any dirt or dust should be removed from the machine. This can be carried out by means of compressed air. If the machine has been exposed to a damp atmosphere it must be thoroughly dried before being put into use. Electrical connections must be made in accordance with the manufacturer circuit diagram. Consult technical support in case of any doubt.

Page 139: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

460 Water and Sanitation

Switchgear Set mounted panels are completely wired so no installation or connections between panel and engine/alternator are required. Floor mounted panels, if possible, should be mounted on their own plinths at least 150 mm (6") above the floor level and should have easy access to both front sides and rear for maintenance purposes. If you are restricted for space at the rear of the panel advise your supply department on the order so that the panel can be designed with all cable connections being made at the front or side of the panel. The panel should be bolted to the foundations with 1/2" rawl bolts and should be protected before commissioning with a dust cover.

Cabling Please ensure the correct cross sectional area of cable between the alternator/panel and distribution board is used and is adequate to carry the full rated continuous output of the generator, allowing for derating in high ambient temperatures. Butyl rubber EPR or CSP cable is recommended for main connections, allowing for a generous loop before the cable enters the alternator terminal box because of the vibration caused by the set starting. If long cable runs are involved you can run the cable to a terminal box and then use flexible connections between the terminal box and the alternator. For the D.C. wiring to the engine we would normally recommend a 1.5 mm 2 PVC cable, except battery charge circuit which should be 4 mm 2 . Should the panel be more than 10 metres away, give the exact information when ordering, as a cable of larger cross sectional area may be required.

Attenuator In cases where noise is a critical factor it is possible to fit noise attenuators to the air inlet and outlets which can be designed to reduce the noise levels in degrees down to a virtually inaudible level. Should your requirements involve the application of noise attenuators you are advised to seek from your technical support advice as to the best methods of noise reduction.

Recommended fuels and lubricants See TVECFUEL… and TVECLUBR…

Pre-commission check Familiarise yourself with the individual engine and alternators recommendations before attempting to start the set. However generally the following points should be checked before the first start: (a) All connections are tight and leakproof, including cabling to auxiliary terminal box. (b) All protective coverings used in packing are removed. (c) Check the fuel, lubricating oil and coolant levels are adequate; top up if necessary. N.B. Engines will not run efficiently if over filled with oil. (d) If the engine has not been run for a month it may be necessary to prime the turbo charger bearings, if fitted. See engine manufacturer's recommendations. (e) Prime fuel system. (f) Charge batteries and connect to unit. (g) Check alternator connections.

Page 140: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 461

(h ) Check all protective covers have been removed. Remember relays and timers are clamped for shipment. (i) Check fuses are in holders and correctly rated. (j) Isolate circuit breaker from load. When you are happy all the conditions above have been satisfied, you can now run the set. Should the engine not fire after 20 seconds cranking release the starter, pause for 30 seconds and repeat procedure. If after 4 attempts the engine does not start investigate the cause.

Typical maintenance procedure Listed below is a typical maintenance procedure, but you are requested to refer to the manufacturer's handbook for specific requirements related to your engine. Before attempting any maintenance on the engine, disconnect the batteries and on stand by sets, isolate the mains. Daily Check lubricating oil level and top up to level shown on dipstick as necessary. Check coolant level and top up as necessary. Check fuel oil level in daily service tank and replenish as necessary. Weekly Above plus: Check level of electrolyte in battery and top up with distilled water as necessary. Test run plant for 60 minutes preferably on its rated full load. Monthly Above plus: Drain sludge from fuel tank. Inspect injectors and service as necessary. Inspect all filters and service, clean or replace as necessary. Inspect condition of all hoses and belts. Replace and tighten as necessary. Inspect governor and service as necessary. Inspect turbo-charger (if fitted) and prime bearing housing if necessary. Inspect battery charging alternator/dynamo and starter motor. Service and/or replace brushgear if necessary. Inspect all points requiring greasing, including alternator bearings and grease as required.

Page 141: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 463

Electrical technical data

Electrical symbols

Page 142: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

464 Water and Sanitation

Three Phase Formulae kW = kVA x Power factor P.F. kW = H.P.x 746 .

1000 x Efficiency (Eff.) kW = Line Amps x Line Volts x 1.73 x P.F.

1000 kVA = Kw .

P.F. kVA = H.P.x 746 .

1000 x Eff.x P.F. kVA = Line Amps x Line Volts x 1.73

1000 Line Amps = kW x 1000 .

Line Volts x 1.73 x P.F. = kVA x 1000 .

Line Volts x 1.73 = H.P.x 746 .

Line Volts x 1.73 x Eff.x P.F. H.P. = Line Amps x Line Volts x 1.73 x Eff.x P.F.

746

= kVA x 1000 x Eff.x P.F. 746

= kW x 1000 x Eff. 746

Page 143: 2002. Emergency Relief Items Catalogue 2002

Emergency Relief Items Catalogue 2002

Water and Sanitation 465

Table Showing the Full Load Current of Three Phase Sets

Table showing the full load current of three phase sets

Standard three phase voltages 440/254 415/240 400/230 380/220 220/127 208/120 kVA

……….………………………… AMPS …………………………………. 1 1.3 1.3 1.4 1.5 2.6 2.8 2 2.6 2.7 2.8 3 5.2 5.6 3 3.9 4 4.3 4.5 7.8 8.4 4 5.3 5.5 5.7 6 10.5 11 5 6.6 6.7 7.2 7.6 13.1 14 6 7.9 8.3 8.6 9.1 15.9 16.7 7 9.2 9.6 10.1 10.6 18.4 19.5 8 10.5 11.1 11.6 12.1 21 22.3 9 11.8 12.4 13 13.6 23.6 25 10 13 13 14 15 26 28 20 26 27 28 30 52 55 30 39 41 43 45 78 84 40 53 55 57 60 105 110 50 66 67 72 76 131 138 60 79 83 86 91 159 168 70 92 96 101 106 184 194 80 105 111 116 121 210 222 90 118 124 130 136 236 250 100 131 139 144 152 264 278 200 263 275 289 304 525 556 250 330 345 361 379 651 696 300 394 413 434 457 789 834 400 525 550 578 609 1051 1110 500 660 690 722 758 1302 1390 600 780 826 868 914 1578 1665 700 920 977 1010 1068 1845 1945 800 1050 1100 1156 1218 2102 2220 900 1182 1239 1302 1371 2367 2502