MEETING ATTENDANCE LIST Licensee: Enterov Plant: Subject: Vermont Yankee Nuclear Power Station General Electric Steam Dryer Analysis Methodology Date: July 21, 2004 Time: 8:00 a.m. Location: NRC Headquarters, TWFN Room 8A1 Name Title Organization 15"O Ais Mf IC I nq4UVL 0 P"C~ ~1 PJr'-Io De-.l 4zg ~n-k c-F4~t~A L~S'e~cE? GAPL ew~i /41 ~c Fh ske- e &V,0104~A-s !I 5r-r -r'tee AtLC, I/4L4 XMEg- SC-HjAe6- i'f1PA6E12-~ 44 -Q CAfm Cty-7~ -2-5-1M_ _ _ __A W_ _ _ _ _ _ -7 t :i csht~ -& 67 1, 64~r/ /97/6d• _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ A l 2 . -7 k ATTI!C~4mtxr t

Upload: others

Post on 16-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

MEETING ATTENDANCE LIST

Licensee: Enterov

Plant:

Subject:

Vermont Yankee Nuclear Power Station

General Electric Steam Dryer Analysis Methodology

Date: July 21, 2004 Time: 8:00 a.m.

Location: NRC Headquarters, TWFN Room 8A1

Name Title Organization

15"O Ais Mf IC I nq4UVL 0 P"C~ ~1

PJr'-Io De-.l 4zg ~n-k

c-F4~t~A L~S'e~cE? GAPL ew~i

/41 ~c Fh ske- e&V,0104~A-s !I 5r-r -r'tee AtLC, I/4L4

XMEg- SC-HjAe6- i'f1PA6E12-~

44 -Q CAfm Cty-7~

-2-5-1M_ _ _ __A W_ _ _ _ _ _ -7 t :i

csht~ -& 67 1,

64~r/ /97/6d•_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ A l 2 . -7 k

ATTI!C~4mtxr t

Page 2: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

2

Name Title Organization

reI{A C. L4qr tqozr ^A1v 46/tR/g

UL e q2 R lzo0 vc ecy Aw 6gqec lq ftJo/IAPR D

ARLI&6 twaOwM rDE sf~ A2

___, E_____ ____ __ - ;e j - 2t-f.

_ _ _ _ _ / -3ecj C /?4- A C7AJE

7%Dz4 CccLo4 1rtt '1l 6e-ThŽ C4T42 AiR-iR c-iIE ^ EB

bi IA -L70tJ Scc~ S7h5 <E,% gSfNs/S,7$ B

cb 5 g c _ _ _ _ _ _ _ _ _ _ __36S

__ __ __ _ __ __ _ ___________________,U DJ r$D IE/' E .4 /e4@ / 40G

G 2),. -c< 'sHO'I AzA7;5w

Lo '4 5 4$)u ;71-k~lc(. t*- 6 'I E ee,6,) _ _ _ _ _ _ _ _ _ _ _ _ _

Si^ FoSR( e91e. 6- kI4SC MA-r--S 60j

(79-z& /izri D C f 4, e /t - VY

kfi zx a A sor v t r/8ze/ c /aad g"it cr /A< F a. t lSG

Do^ _ _co_ _ _ _L__t _ _ _ls __

Page 3: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

3

Name Title Organization

~~C, , A,

N\l C tA EAT. )-

B ~ xc4 Soel24lo C4SC~C ~/e z/t PA4 ,

S/)G l / A- /CT _ _ _ F_ a__ _ _ _ _ _ _ _ _ _

Ceci w VA> ., e&N -1 -,.

+ 4

+ 4.

t 1-

4. 4.

-4- 4.

4- 4-

I 4

4 4

4 1

4 4

I 4

Page 4: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

MEETING ATTENDANCE LIST

Licensee: Entera

Plant: Vermo

Subject: Steam

Date: July 22, 2004

nt Yankee Nuclear Power Station

Dryer Analysis Associated with Extended Power Uprate Request

Time: 8:00 a.m.

Location: NIR ( HPWnnlr inrforc rlA;FK Rnnm I ('I CI .- - -*-ttJ1t 1tS . .' V V * * I * *tfl*, * .4 S I

Name Title Organization

R_______ _ F SZIs, P Ar M I&.-/CalL/eLr'

Leslie wd(erpe~ tkex eS

,allu vzi,-r 6*r-vawuc ty RiA 4- MA01-1EA &gE-A

VXIAnpl 46 ZZX Mu -ee 6rH-xJ06xs~

GOhl0Ae emkccfi- Peo,)c-cl O4fE 6q-Frs I~ ht /w>e

t~e ___________________G

RA: S A'NANTRXJ.\V\ ...xr F/,1 C& /72

_ __ _

&/ci- OSL7C(/C P,%QS'ecI6 /k41 L9Eir /YY~ec6

t nz'Rs 6c/) Es k1L' 2c /Cs- r

JU _ C____ _R__________

_ G•NuS ~ c. S l Ce.s C/t JgP° Dv1 Aj

__________ _ 7t1n-I s

I '7

ArTP#^CAW :D

Page 5: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

2

Name Title Organization

' • S 2 _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ __ __eC_ _ _ _ Avftt4 VIt~ Ieer~~ qb|9Z -

-M APLK _'__________._

._v- _ -__,-

tlv-r4pqk) VT fo-AvU.c..r i Sv Alt

a4e~nyi W-t'l fikants,QhZv3le, [bJ N ri-g//36 Thu s Ii z /A ieC /

T,

4mvd1 /4<J ~ Se-e~ c A/L2C AJ~c/*&- N64z¢ /tX2>A45 s y 'z'& 6X/ e{~

Q&&fa4 AeI .IR t Ci&

,LA,A14L /-JQ - ct _ L X Al rcA.S V.c.

V;V- (hC4A-\. ' MecAE. EV~ AW. i A .. ~ t _ _ _ _ _ _ _ ._ _ _ _ _

Page 6: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

3

Name Title Organization

'V7 .~ (11cAZinhA -L uAS~ p 1 JIeLv I~

cEda4n .4 0!4. 6Ž-J1Z-eeif5))i 6~F-ME

~JeFF~e~,IA tso1 I& ,Q /u/o__________ TL, SA.>

4 4

4 4-

4- 4-

+ 4-

I

Page 7: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

~-- -

UBWR Steam DryerStructural Analysis Methodology

July 21, 2004"IDye trctra Mars etiodl ogAebg121¶O 42J

Agenda

* Meeting Goals* Meeting Structure* EPU Operating Experience* Fluctuating Load Definition* Structural Analysis Techniques* Finite Element Model* Fatigue Structural Analysis* Load Combinations* Transient and Accident Load Definitions* Primary Stress Structural Analysis

DyrStrit W- AagW4ehaooY~ee~~72 ~ rd ~~

A -Ar"to.Et 4 3Imagination at work

1

Page 8: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

Meeting Goals

* Update NRC technical staff on BWR steam dryerstructural analysis methodology

- Load definition- Structural analysis

* Provide generic basis and background informationsupporting EPU dryer analyses

* Provide information supporting VY dryer analysisreview

Significant improvements in methodology havebeen made over the last year

~f~DyerStruturl Aalyss Mll dI~i~e~6'7I~i2O4

Meeting Structure

* Informal question/answer format- Similar to technical audit- Not a structured presentation

* Review- Detailed analysis results- Design record files- Spreadsheets, etc

* Review of generic methodology- Vermont Yankee EPU analysis used as example

* Copies of materials requested by the staff will beformally provided after the review

5 -ID

Imagination at work

2

Page 9: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

GENE Technical Discussion Leaders

* Fluctuating Load Definition* Structural Analysis

Techniques* Finite Element Model* Fatigue Structural Analysis* Load Combinations* Transient and Accident

Load Definitions* Primary Stress Structural

Analysts

Dan PapponeRichard Wu

Alex PinskerHenry HwangHenry HwangDan Pappone

Henry Hwang

FDTY .-' ~wta ioDz2*4ye,8 ,M66finjj7 °-121/2greeu 4211 Xfp

Steam Dryer Design Basis

* Original Design Requirements- Not ASME-coded component- Fatigue from flow-induced vibration not explicitly considered- Maintain structural integrity for outside steamline break accident

* No loose parts* Deformation acceptable

* Current Dryer Analyses- Finite Element Model of dryer- Fluctuating pressure loads defined- Fatigue from flow-induced vibration analyzed- Normal, upset, faulted conditions analyzed- ASME code criteria used as guidance for modifications

;isvodgMtn7

Imagination at work 3

3

Page 10: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

EPU Operating Experience

.el i i I / N / N 4, ft/ / /

I Nearly 50 Reactor Operating Years of EPU Experience |

11 ., St -d r?,nal1- I Methodology- I'l

Imagination at work(

4

Page 11: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

Relative Hood Stresses

o14160 psi zvv366 psi

Flat Hood With Strut, Sianted Hood With Plates

2294 psi

vYNS Modifiede650 psi Dryer

FHlt Hood Without StrutsCarved Hood With flates

)20ri4- '>." .S *r

Overall Dryer Screening120

100

t20

m~~m5 . .~ .ie' ., . . .

etc

is --fi

imagination at work e

5

Page 12: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

BWR/3 Dryer Failure History (QC2)

lower cover plate atQC2

High cycde fatiguedue to highfrequency fluctuatingpressure (120-230Hz) thin cover plate,small welds, potentialresonance

Replaced coverplate with Wplate

Developed dryer cornponenlstructural analysis

Used more robust attachmentwelds.

May 2003 Cracks In outer High cycle fatigue Removed diagonal braces Modifed dryer structuralhood, broken due to low frequency from outer hoods analysis to account forbraces and struts In tluctuating pressure Replaced outer hood pltes fluctuating pressure leadthe outer hood loading Hz) Rethac-dpcuter ooda definition over fuit frequency

teotrho opeationg wi Hz with 11 plate range. for aSl dryer typesdamaged ovwer plate Added external gussetscontributing factor

March Cracks In plate at Local stress Fult height 1 vertical hood Solid submodelsforNigh2004 gusset lps, broken concentrations not plate stress locations used to

tie bar welds modeled In sufficient Futt height external gussets supplement 3D shell FinitedetaEliln model

Full penetration shop welds on Analysis Incldes gusset Uspexternal gussets design and weld design

11- 90 I , . . - -e- - ��, iW f -,T..- i-'il� 0 x" 54Si . .a,-r !IRA '-" " t... 7ft 't�"'

-, .1,

Hood Failure Locations

_I Top of Outer Hood

- Location)

Plat

ah 'r, g,,_,r:fi$*trsfi42;j~t.Ol~sxQQj~zotlw~shiSb& ¢u;>,4i>,4,~,s(,WKton)8ss=

Imagination at work

6

Page 13: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

Review Topics

* Load Definition

* Structural Analysis

* Plant Application

Conclusions

* Significant progress in structural analysismethodology

* Overall methodology is conservative

* Dryer modifications assure structural integrity atEPU conditions

- Increased design margin at critical locations

'H,.a+S.et;s~~l.;;~,} 4;.b ;:t:f . ,t-.t-tt-. i<ntZ..r-y1>t 4-A..,;~ , ,i,

Imagination at work

7

Page 14: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

Closed Session

Iogy.';ee]ng7/fi.Dye SiutIa A,~yi M e U 6

Fluctuating Load Definition

* Generic load definition- Assumptions- In-plant test data- Scale model test data- Reference load definition

* Plant-specific application- Load scaling

* Load definition confirmation

Imagination at work t8

Page 15: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

Structural Analysis Techniques

* Equivalent static method- Frequency analysis using reference load- Load scaling- Dynamic amplification, stress concentration

factors

* Response spectrum method- Pressure load to response spectrum transform

* Acceptance Criteria

. a

Finite Element Model

* Model Assumptions

* Dryer components modeled

* Shell model

* Solid submodels

0~ I

YD rtrcua nlssIehdlyMetn '2jO ;44Sdi8

Imagination at work m

9

Page 16: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

Fatigue Structural Analysis

* Analyze current power, EPU power conditions

* Benchmark current power results againstacceptance criteria

* Evaluate EPU results against acceptance.i er

c' Sndua rIiIthi Meng 220 ifflder

Load Combinations

* Operating conditions- Normal

- Upset- Faulted

* Loads considered- Deadweight- Static differential pressure- Seismic

~-Dryer Structural An 17

imagination at work

10

Page 17: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

Transient and Accident Load Definitions

* Differential pressure loads- Forward flow transients (e.g., SORV)- Reverse flow transients (e.g., TSV)- Steamline break accident

* Seismic loads-OBE- SSE

Ka* ______

Primary Stress Structural Analysis

* Analyze individual load components for eachoperating condition

* Combine stress results for individualcomponents

* Assess overall stress results againstacceptance criteria

g~~e-;-t.^,~z~ .z vf';Al-''.s4-2t. ,.ue...~- ryXi s.> ,,9;e99.2 S o

Imagination at work

11

Page 18: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

a-%Entergy

Entergy VYPower Uprate Project

,;~ 'I.:

Steam Dryer RAI Revieew

July 22, 2004

1

Page 19: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

-EnStmgy

< Main Steam Dryer- p

2

Page 20: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

7w What we know-I.

Significant improvement in methodology- Dryer Finite Element Model adequately reflects dryer

performance under defined loadVY Modified Dryer relative stresses are less thanother dryer types under the same load

* Dryer Loads are adequately defined* VY Steam Line velocity at EPU is less than

QC/Dresden original steam velocity* Reasonable Assurance that Dryer will perform per

current design requirements at Extended PowerUprate Conditions at Vermont Yankee

3

Page 21: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

Future Activities

Obtain and evaluate VY Plant Specific data* Comprehensive, deliberate, well monitored

power ascension

4

Page 22: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

Quad Cities Experience

Methodologies developed after QC2 failuresaccurately predict high stress locationsConfirmed by actual high stress failurelocations

5

Page 23: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

a Etergy..- -. .,,-r~

,; . .,

.n Industry Steam Dryer Experience_i n _ .aafl .i..M . .-

Ma | Nearly 50 Reactor Operating Years of EPU Experience

120

110

0a)

0

Edg 100a)

90

80

X 0A?

'S.b

e" I I

',:§ 5.

&, b

6

Page 24: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

- tergy

.77 . . t, . .:4~. .7T-

"'I.'trt Main Steam Line Flow Velocities220.0

200.0

Up14)

9 180.0

04)

l 160.00

S

E4) 140.0

120.0

100.0

~ a. ~' ….CMO0a)

C CD

8m mm m ca E 7

Page 25: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

;!:7 Overall Dryer Screening9 JST.i��� �.fra'. U.

Et " 20

100 -

80 -Ea

0o

co.0

(U

.i

60 -

. . . . . . . . . . . . . . .-.

40 -

20 -

0 - ......_ l OO.OO.OOO O O OO 00 -- O 2o 1 o _ 5- 5____ -_° - ° ° -00000 ------- ° ----- ---------------- ° 0 °

CD (Da a- a: i ii! ! a:a! a:a! a a:CD !i~ a! a!aD60 mimmmmm mmmmmmmmmm mmM mmmmmmmmmmmmmmmmmmmmmmm c- N mm m om

(2) 0

(aa

8

Page 26: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

-En terg

VY Steam Dryer Analysis

GE developed Finite Element Model of VY Dryer. Loads defined based on similar plant instrumented

dryer dataResults: identified increased stress areas at uprateconditionsDeveloped robust modification - industry experienceincorporatedRe-ran the Model incorporating the modification andvalidated stresses were below Code limits at uprateconditionsSignificantly increased structural margin

9

Page 27: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

--En tefgy

VY Steam Dryer Inspection

7 .Internal & external visual inspection of steam dryeraccessible areas

* No outer bank or lower cover plate cracking found

10

Page 28: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

a=Enteergy

VY Steam Dryer Inspection7 .Some visual indications were found: consistent with BWR industry

experience• Two 3" cracks in dryer steam dam were repaired & strengthened

. Caused by fabrication residual stressesSeveral intergranular stress corrosion cracks (IGSCC) were found(dryer end bank and drain channel)

. Caused by sensitization and weld residual stresses fromoriginal welding

. Not structurally significant

11

Page 29: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

=I e rtfgy

Steam Dryer - Strengthening Design

Modifications• Lower cover plate - Increase from 1/4" to 5/8" Upper vertical and

horizontal cover plates in outer hood - Increase from 1/2" to I"• Remove internal diagonal shipping braces

. Eliminate stress concentrators which were the crack initiators for theQuad Cities Failures

* Replace dryer bank tie bars and improve weld attachment• Add six, full-length external gussets to hood plates

Full penetration versus fillet welds. Gusset shoe provides enhanced weld strength

* Employed low carbon stainless steel - IGSCC resistant

12

Page 30: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

'-~ Eterg-y

.. ,�.. Z -��MINh*II VY Dryer - Before & After Strengthening

-.

t1 s'I

IA .

mug

Before| After 13

Page 31: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

A-- Eergy

m AdVY Steam Dryer Strengthening - Tie Bars

14

Page 32: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

Af-

~-,-~Entesgy

V4 -- '7= M. .y

hitEr Y Steam Dryer Strengthening - Hood

15

Page 33: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

-- -Entergy

VY Steam Dryer Monitoring

* Measurements consistent with SIL 644* Moisture carryover levels• System parameters (flow and level)

* Inspection in planned refuel outage ('8months of <115% uprate operation)

16

Page 34: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

W tergy

~I.- ,-W VY Acoustic Circuit Model

m Collect VY Main Steam Data

* Develop Acoustic Circuit Model

n Reconcile Test Results with GE Analysis

17

Page 35: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

-Entifflgy

, VY Main Steam System Data Collection

. Measurement locations more extensive than otherstations* Pressure data taken with high speed recorder at:

• MSL venturis (one on each steamline)

• Vessel instrument reference legs (2)

* Main steam header

. Strain Gauges located on each steam line close to vessel

* Data taken at 80%, 85%, 90%, 92%, 95%, 97% and100% power

18

Page 36: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

1 -En te gy.. .

I. ,. .-dVY Steam System Data Collection Map

-.

RPV LevelInstrumentReference Leg

High SpeedPressureSensors -

(10)

I

19

Page 37: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

-5 . I.4-V e '!L..

VY Steam Dryer TimelineFeb 2004 Mar2004 , Apr 2004 " May 2004 Jun 2004 Jul 2004 , Aug 2004 X Sep 2004

I I I I I I I IVY Review/

Oversight

Tech ReviewRAI Set iSubmittal

GE AuditRAI Set 2Submittal

Design

Inspection

Modification

<;;.t!';;.F.Q:8&,sitActB)a.4-< ;4 d1.w s ,;o '''t -jgfet a

r771

A

F;7.,��75, 77-1

APiping Vibs Data

MS System Data

Acoustic Ckt

ACM Complete

A

AL20

Page 38: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

VY Uprate Testing and, ___.._._.._._.____ .eInspection Plan

* Two Step Uprate

* Gradual Power Ascension Test Plan with predefined hold points* Pre-uprate testing provides baseline data

* Measurement program• Main Steam and Feedwater FIV Accelerometers• Steam System Pressure Transmitters• Main Steam Line Strain Gauges• Installed Plant Equipment

Inspection in planned refuel outage (8 months of <115% uprateoperation)n Detailed inspection consistent with SIL 644

21

Page 39: 2004/09/02-Attachments 1 through 4 of 07/21/2004 & 07/22 ... · BWR/3 Dryer Failure History (QC2) lower cover plate at QC2 High cycde fatigue due to high frequency fluctuating pressure

7I. Q&A--r.- . As....-

22