2008 product catalogue

255
2008 Product Catalogue A comprehensive range of Air Conditioning Systems from Mitsubishi Electric

Upload: xlongg7

Post on 22-Oct-2014

420 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: 2008 Product Catalogue

2008 Product Catalogue

Telephone: 01707 282880Post Sales Technical Support / Spares and Warranty: 0870 3000 300

email: [email protected]

web: www.mitsubishielectric.co.uk/aircon

UNITED KINGDOM Mitsubishi Electric Europe Air Conditioning Systems DivisionTravellers Lane, Hatfield, Hertfordshire, AL10 8XB, England. General enquiries Telephone: 01707 282880 Fax: 01707 278674

IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland. Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531)

Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2008. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Company’s General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.

Printed in April 2008

SAP No. 214760

www.greengatewayinitiative.co.uk

Designed by Square Bear Ltd 01604 899099. Square Bear Ltd are committed to using FSC certified paper and printers, wherever possible.

The laminate used on this brochure is environmentally friendly, recyclable and biodegradable

Features Key

2008 Product CatalogueA comprehensive range of Air Conditioning Systems from Mitsubishi Electric

Page 2: 2008 Product Catalogue

Mitsubishi Electric Partner ProgrammeOpen to all contractors - large or small - the Mitsubishi Electric Par tner Programme offers contractors atotally new and unique set of benefits. There are two categories within the programme - Accredited Installerand Business Solutions Partner - these levels being a straight-forward reflection of the Partner’sstage of growth, with all customers signing up to the programmes standards and committing to continued training and professional development.

For more information please contact your local sales office

Mitsubishi Electric Training OptionsMitsubishi Electric has four state-of-the-ar t training suites based at different locations around the countr y for your convenience.Providing training for all levels of exper tise, our courses are taught by experienced engineers, with a wealth of knowledge and are all CPD accredited.

For bookings please telephone 01707 278797

Systems marked with the ECA logo have an energy label of A or B, are registered on theEnergy Technology List and hence qualify for 100% first year enhanced capital allowances(whole system cost and ‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk

Nominal conditions cooling: indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.Nominal conditions heating: indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. Winter; indoor 21˚C DB; outdoor -1˚C WB.

Notes: Recommended fuse ratings given throughout this price list are based on British Standard (BS88).

the name Mitsubishi is synonymous with excellenceKnown the world over, Mitsubishi is a trusted global leaderassociated with a variety of products and services. Founded in1907, the company known today as Mitsubishi Electric, quicklyrose to the forefront of the air conditioning industry - a position we still enjoy today.

Unsurpassed air conditioning from Mitsubishi ElectricAir conditioning is an ideal way of controlling the air quality inside any building, large or small.Not only does it cool in the summer months but air conditioning can also heat, replacing traditionalheating systems. More and more people today are experiencing the benefits of comfortable working,living and leisure environments made possible with air conditioning. As market leaders, we prideourselves in providing high performance, competitive systems with low running costs.

Protecting the environmentMitsubishi Electric boasts an explicit commitment to sustainable business practices such as energy and resource efficiency, minimising ecological impacts of our products and reducing greenhouse gas emissions. We are the only manufacturer in the industry recognised by Portfolio 21 as one of the top five companies in the world for our sustainable environmental policy. All of our factories are also ISO 14001 registered, the international standard that specifies a process for controlling and improving a company's environmental performance and with the advent of our Green Gateway Initiative, we strive to constantly promote best practice.

The Forest Stewardship Council (FSC) is an international network promoting responsible management of the world's forest. The paper this catalogue is printed on supports the development of responsible forest management worldwide. The wood comes from FSC certified, well managed forests, company controlled sources and/or recycled material.

Page 3: 2008 Product Catalogue

Page 13-52

Bigger, better and easier to use: the new2008 Mitsubishi Electric Air ConditioningProduct CatalogueThis revised catalogue offers you more information than ever before. The first thing you’llnotice is that the 2008 catalogue is bigger than before. That’s because the MitsubishiElectric air conditioning range contains many new models, plus a fully comprehensiveselection of control options to choose from.

In addition to increasing the range, we’ve also tried to help you find what you need morequickly and efficiently. We hope you will find it an interesting and informative read.

If there is anything not covered in the catalogue and you want to know more, simplycontact your Mitsubishi Electric supplier who will be delighted to help you. Alternatively, youcan log onto our website at www.mitsubishielectric.co.uk/aircon for further information.

Page 53-116

Page 117-197

Page 199-217

Page 219-254

Contents

Page 1

Page 4: 2008 Product Catalogue

M Series / Mr SlimSplit-System Air Conditioning

Page 5: 2008 Product Catalogue

Mitsubishi ElectricSplit-Systems

M Series and Mr SlimFor the last couple of years Mitsubishi Electric’s M Series and Mr Slim range of split-systemshave gradually moved closer together, in terms of features and benefits, capacity and now mostimportantly in terms of control. While both ranges maintain their individual brand identity, allof our models have benefited from massive investment by Mitsubishi Electric, the overall resultbeing a vastly improved and more flexible collection of split-systems.

One of the most important features of the inverter range is the adoption of a new version of A Control, allowing the standardisation of the M Series and Mr Slim ranges, as well as strengthening the remote controller functionality. As a result of this it is now also possible to connect Mr Slim indoorunits to MXZ Multi-Split outdoor units, allowing for complete design flexibility. The Mr Slim StandardInverter models have further increased the range, offering a lower cost option, whilst still incorporatingMitsubishi Electric’s energy saving inverter technology. Also new to the Split-Systems range are the newhigh COP, MSZ-FD M Series models, our most efficient wall mounted units to date.

A Control is Mitsubishi Electric’s control mechanism for providing standard remote controller functionsalongside system diagnostics, fault code monitoring and the ability to interface with the MELANS(Mitsubishi Electric Air Conditioning Network Solution) equipment such as the G50 CentralisedController, TG2000, Modbus, Trend, LonWorks® & BACnet® etc. A Control has now been furtherimproved by Mitsubishi Electric, providing increased flexibility alongside greater functionality.

Page 4

Page 6: 2008 Product Catalogue

Inverter technology saves energy for two main reasons:1. The compressor varies its speed to match the cooling or heating load and therefore consumes only the power necessary

to match the exact requirement of the room.

2. When an inverter driven air conditioner is operating at partial load, the energy efficiency of the system is significantly higher than at full load. In a typical application, partial load conditions prevail for more than 90% of operation time. A fixed speed system can only operate at 100% capacity and cannot match the annual efficiencies of an inverter system.

The entire R410A M Series and Mr Slim ranges areavailable as an inverter option

The adoption of this technology as standard by Mitsubishi Electric, shows our commitment to both increasing your savings as well as protecting the global environment.

Energy Saving: Reduced power consumption

increased efficiency

Page 5

Page 7: 2008 Product Catalogue

Energy SavingTechnology

Application of new technologies in Mitsubishi Electric inver ter systems significantly enhance the generic benefits of inverter driven systems.

Reduced power consumptionincreased efficiency

Reluctance DC Rotary Compressors

The centralised winding DC motor uses less copper wiring than a conventional versionand features a new high density, centralised winding method that raises motor windingefficiency to 96%. Units incorporating this motor also benefit from a low starting current aswell as a stable set point.

Highly Efficient Scroll CompressorsThe scroll compressor is equipped with a ‘Frame Compliance Mechanism’ that allows movement in the axial direction of the frame supporting the moving scroll. This construction realises up to a 27%improvement in compressor efficiency by reducing both leakage and friction losses.

DC Fan MotorA high-efficiency DC motor drives the fan of the outdoor units. It offers up to 60% greater efficiency than an equivalent AC motor.

Simple Par tial Switching Method PAM ControlCompared to the conventional active filter method, the simplepartial method PAM (Pulse Amplitude Modulation) control found on the new models helps to reduce energy losses. When combined with the Vector-Wave Eco Inver ter, PAMcontrol also allows for greater power and efficiency.

Normal Inverter vs. PAM

PAM adjusts the form of the current wave so that it is close to that of the supply voltage wave. High harmonics are reduced and 98% of the electricity is utilised.

Time

SupplyVoltage

Current

SupplyVoltage

Time

Current

Page 6

Page 8: 2008 Product Catalogue

Total Energy Conservation

Power Receiver and Twin LEV ControlMitsubishi Electric has developed a power receiver and twin LEVs(linear expansion valves) that optimise the performance of thecompressor. By ensuring optimum control in response to theoperating waveform and outdoor temperature, this technology is tailored to the characteristics of the new refrigerant to enhance operating efficiency.

Vector-Wave Eco InverterThis technology uses a specially designed microprocessor to produce the most efficient waveform in response tovarying compressor motor rpm. By improving operatingefficiency from low to high speeds, annual electricity costs are reduced.

Page 7

Page 9: 2008 Product Catalogue

* 1Assuming existing pipework is suitable for R410A operational pressures * 2Not available on the MXZ-8A140VA Multi-Split outdoor unit or Classic Inverter (MSZ-HC)

Re-use of existing pipe work

In general the upgrading of existing R22 systems to modern efficient R410A systems has been a difficult or expensive option.This is because the existing pipe work would either have to be replaced,or cleaned with dedicated specialist equipment. These actions werenecessar y as the chlorine residue from R22 system pipe work caused chemical reactions with the lubricating oils used in HFCcompressors, the result being poor performance and system failure.

Mitsubishi Electric’s

Replace Technology

Upgrading existing R22/R407c systems to efficient inver ter models* 1

The M Series Inverter*2 & Mr Slim PowerInver ter ranges incorporate ‘ReplaceTechnology’ to allow the upgrading of systemsusing existing pipe work without the need toapply any special cleaning machines. Sizes 25to 71 utilise the Mitsubishi Electric patentedHard Alkyl Benzene (HAB) oil, a unique oilthat is more tolerant of contamination. Bycombining this oil with developments in oilseparator technology it is possible for thismodel to use existing pipe work without anyspecial operations.

Sizes 100 to 250 continue to use the morefamiliar Ester Oils that are sensitive tochemical contamination. To allow these modelsto utilise existing pipe work a unique ‘ReplaceFilter’ containing activated charcoal has beenincluded in the refrigerant circuit. During

commissioning the system is operated in‘Replace Mode’, this operation removing allthe chlorine contamination from the existingpipe work allowing trouble free operation.

Replacement filter (Sectional photo)

Activated carbon (absorbs chlorine and other chemicals)

Filter

RefrigerantRefrigerant

OutletInlet

Page 8

Page 10: 2008 Product Catalogue

Reduces installation time & costs

AdvantagesFor tenants / owner � Reduces installation time causing less disruption of business� Saves on installation costs

For installer� Installation time is reduced significantly� It is not necessary to purchase new piping for R410A refrigerant� Time-consuming pipe cleaning is not necessary when employing Replace Technology

Page 9

Page 11: 2008 Product Catalogue

Model / Size

MSZ-GA/GB/GC-VA

MSZ-FD-VA

PKA-RP-GAL/FAL(2)

MFZ-KA-VA

SEZ-KD-VA

PEAD-RP-EA(2)

PEA-RP-GA

SLZ-KA-VA

PLA-RP-BA(2)

PCA-RP-GA(2)

PCA-RP-HA

PSA-RP-GA

Split-System Product Range OverviewOutdoor Units

M Series Inverter

(Multi-Split)

M Series Inverter

MXZ-4A80VAMXZ-5A100VA

M Series Inverter

Multi-Split

22(2.2kW)

Multi-Split only

25(2.5kW)

35(3.5kW)

50(5.0kW)

60(6.0kW)

71(7.1kW)

0.9kW Cooling Capacity

Indoor Units

MXZ-3A54VAMXZ-4A71VA

M Series Inverter

Multi-Split

MUZ-GC35/FD25-35VA(H)SUZ-KA25/35VA

MXZ-2A52VA

MUZ-GB50/GA60-71VASUZ-KA50-71VA

Page 10

MXZ-8A140VA

M Series Power Multi

M Series Inverter

MUZ-GC25VA

Page 12: 2008 Product Catalogue

44kW Cooling Capacity

100(10.0kW)

125(12.5kW)

140(14.0kW)

200(19.0kW)

250(22.0kW)

400(38.0kW)

500(44.0kW)

Mr Slim Power Inverter

PUHZ-RP60/71VHA3

Mr Slim Power Inverter

PUHZ-P100VHA2

Mr Slim Standard Inverter

PUHZ-P125-140VHA2PUHZ-P200/250YHA

Mr Slim Standard Inverter

PUHZ-RP35/50VHA3PUH-P125-140YHA

Mr Slim

Page 11

PUHZ-RP100V/YHA3PUHZ-RP125/140V/YHA2PUHZ-RP200/250YHA2

Mr Slim Power Inverter

PUH-P100YHA

Mr Slim

Page 13: 2008 Product Catalogue

Available in a variety of options, our Split-System

range fits in wherever it’s needed. Indoor units

can be four way blow cassettes, ducted, wall,

floor or ceiling mounted. Up to eight indoor units

can then be connected to a single outdoor unit

providing the ideal air conditioning solution.

Designed to fit anywhere

The adaptable Split-System range

Simple technologyat its best

Systems marked with the ECA logo have an energy label of A or B, are registered on theEnergy Technology List and hence qualify for 100% first year enhanced capital allowances(whole system cost and ‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk

Nominal conditions cooling: indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.Nominal conditions heating: indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. Winter; indoor 21˚C DB; outdoor -1˚C WB.

Page 12

Page 14: 2008 Product Catalogue

M SeriesRoom Air Conditioning

Page 15: 2008 Product Catalogue

Surprisingly affordable, the efficiency of the M Series range presents substantial savings inheating mode, when compared with more conventional heating systems. Additional features such as ‘Econo-Cool’ allow airflow to beprecisely directed towards users, allowing settemperatures to be raised by 2ºC with no loss incomfort and a 20% gain in energy efficiency.

Flexible enough to suit a range of applications, the M Series includes models that will run up toeight indoor units per outdoor unit. With vastlyincreased pipe length and height differences overits R407c predecessors, the M Series is extremelyversatile, helping to make system application easier.This diagram shows how a typical multi-splitsystem could be installed into a medium sizedoffice for example.

Highly efficientwhilst ozone friendly too

The entire M Series range is now available using Inverter technology. By matching the compressor speed to the cooling or heating load of the room, up to a 30% reduction in power consumption can be achieved.

Increasingly aware of the importance of protecting the environment, the M Series rangeuses the (ozone friendly) refrigerant with zeroODP (Ozone Depletion Potential) - R410A.Many models also make use of a new air filtering system containing the compoundCatechin, which helps to improve air quality andprevent the spread of bacteria and viruses.

M Series offers the end user some of the highestenergy efficiency ratings available, alongsidegreater application flexibility. Lower runningcosts and increased comfor t forconsumers are vir tually guaranteedand Mitsubishi Electric has made M Series the natural choice fortoday’s small to medium sizedapplication market.

The M Series range

Designed to heat or cool small to medium sized applications, the M Series range provides a versatile, yet affordable air conditioning solution. Quick to install and also one of the quietest units on the market (as low as 20dBA* 1), this newly designed, attractive range offers the perfect way to ensure a comfortableenvironment with the minimum of disruption.

* 1MSZ-FD25VA

Perfect for small to medium sized applications

Page 14

Page 16: 2008 Product Catalogue

Designed to f it

anywhere

Page 17: 2008 Product Catalogue

Clean, ComfortableEnvironmentCatechin Filter

Catechin is a bioflavonoid that is found in green tea. Bioflavonoids are a group of chemical substancespresent in many plants, that have both antiviral and antioxidant qualities. In addition to these benefits,Catechin also offers excellent deodorising characteristics; which is why Mitsubishi Electric uses thiscompound in its air conditioning filters to not only improve air quality, but to also prevent the spreadof bacteria and viruses within a room. The filter can be easily removed and when washed regularly,deodorising effectiveness should last for more than 10 years. MSZ-G and MSZ-HC wall mountedand MFZ floor mounted systems are supplied with or have the option of the Catechin filter.

“Anti-Allergy Enzyme Filter” mechanism

� Artificial enzyme catalyst on the filament catches the allergens.

� The artificial enzyme catalyst helps the chemical reaction with Oxygen and severs the S-S bonds.*1

� Proteins with severed S-S bonds are no longer allergen proteins.

*1 Mites and other allergen protein consist of sulfur atoms (S) that have bonded together.

Silent Operation

Unlike conventional models with a grilled air intake, wall mounted models feature a smoothly contoured,flat panel finish with a top air intake that not only improves aesthetics, but also helps to reduce noise as the heat exchanger area is fully covered. In fact, noise level during normal operation is only 20dBA for the MSZ-FD25VA, making it one of the quietest indoor units on the market. This is as a result of the multi-angled heat exchanger having a modified fin shape that reduces air resistance, producing a smoother, quieter flow of air.

Alongside this, the wide diameter of the fan produces greater airflow at lower fan speeds and the uneven pitch between each fan blade helps to eliminate unwanted noise.

Technological improvements reducing operating sound levels

Only 20dBA

Page 16

Page 18: 2008 Product Catalogue

Operating StatusMonitoringMonitor lamps located on the right of the indoor unit provideat-a-glance recognition of the air conditioner operating status.When the difference between the set temperature and roomtemperature is more than 2°C, both monitor lamps will turnon. If it is less than 2°C, only the upper lamp will light.

The vane on the MSZ-GC22-35/GB50VA and MSZ-FD25/35VAwall mounted models easily detaches, allowing access to the louvres.These can then be opened outwards (without any special tools) forquick cleaning of the heat exchanger, fan and air vents. Regularcleaning will increase both operating efficiency and energy-savings.

Quick Clean

Design can

reduce your

electricity bill by

approximately 30%

*1Electricity bill comparison of operation under a fixed temperature with 8g of soil on the fan and also without.

Quick Clean Design

Electricity bill increases

by 5%*1

Electricity bill increases

by 25%*1

Heat Exchanger Fan Air Vent

Page 17

Page 19: 2008 Product Catalogue

Powerful Heating CapacityThe VAH outdoor unit is engineered for use in cold regions and is equipped with a powerful compressor, enabling an improvement inheating capacity. The heating power is raised by about 30% over the standard model and keeps the room comfortable even on cold days.

Field Test Result: Size 35. Sweden, 23rd January 2008

Page 18

The New MSZ-FD SeriesThe new FD Series line-up is engineered for high energy efficiency and low sound levels. The I-See Sensor,Plasma-Duo filter system and other superb new functions raise the comfort level to even greater heights.

High Energy EfficiencyWith the latest inverter technology, energy efficiency is improved by about 20%.Specifically, more than 5.0 is attained for both the COP and EER for a size 25.

Quiet RunningA larger line flow fan is included in the FD model. This allows stable capacity with fewer rotations, reducing operating noise.

Page 20: 2008 Product Catalogue

Page 19

The "I-See Sensor" automatically moves from side to side, searching floor temperature over a wide area of 150°.

Conventional air conditioners control indoor temperature by using only thetemperature of the intake air at the top of the room. As a result, the floorlevel temperature, which exerts such a crucial impact on the temperaturethat people feel, tends to be overlooked. The I-See Sensor detects the floor temperatures to ensure constant comfort in the living areas.

Cold air tends to sink to floor level, which is often the cause of over cooling. The I-See Sensor tracks this floor level temperature and adjusts the air outlet temperature accordingly.

Warm air tends to rise up from the floor level, which often prevents that zone from warming up. The I-See Sensor tracks this floor level temperature and adjusts the air outlet flow accordingly.

Besides a pre-filter, the MSZ-FD is also fitted with two plasma air-purifyingfunctions. These functions are engineered to change air dirt particles frommicron to nano-size in scale.

Plasma DeodorisationThe “Platinum catalyst deodorising filter” captures small foul-smelling substances in the air, then breaksdown the source of the odours with the power of the ozone generated in the plasma electrode unit and the platinum catalyst contained in the filter.

Plasma Electrode UnitA plasma electrode unit is mounted inside the airconditioner. Electro-discharge is used to generateozone & plasma. The collaboration betweenozone & plasma and two special filters creates a dynamic plasma air cleaning function.

Plasma Air PurificationThe “Anti-allergen electric enzyme filter” usesthe power of the static electricity charged inthe filter, as well as plasma generated in theplasma electrode unit to capture the bacteria,pollen and other allergens in the air, which arethen neutralised by the enzyme in the filter.

Mould Fighter mechanismStep 1After cooling operation the Plasma Electrode unit fills the inside of the indoor unit with ozone (O3).

Step 2The heat exchangeris dried for about40mins by the fanmode operation.

The MSZ-FD is equipped with a “Mould Fighter” function designed to suppress the growth ofspores of mould. The ozone generated in the plasma electrode unit attacks the mould spores,reducing mould growth by about 20%.

Page 21: 2008 Product Catalogue

MXZ Multi-Split Systems

� 14kW Inverter Multi System, based on Mr Slim Power Inverter technology

� Ability to connect up to eight indoor units across the M Series and Mr Slim product range within a capacity index of 18.5kW

� Total Pipe Length of 115m / Height Difference of 30m

� ‘A’ rated energy label - High COP (3.91) & EER (3.52)

� Single phase power supply

� Connection of indoor units is through either a 3-way (PAC-AK30BC)or 5-way (PAC-AK50BC) branch box, either singularly or with two in combination

� Individual control of each indoor unit is now possible (ON/OFF and Setpoint)

� Low starting and running currents

� Connection to M-NET system via MAC-399IF-E interface (one per indoor unit needed)

� New Centralised Simple ON/OFF remote controller MAC-821SC-E available for use on all MXZ Multi-Split units. Up to eight indoor units can be controlled from one remote controller (Interface MAC-397IF-E is needed, one per indoor unit)

The MXZ-8A140VA Power Multi Inver ter Heat Pump Multi-Split Outdoor Unit

Ideal for apartments or small commercial buildings

Page 20

Page 22: 2008 Product Catalogue

Outdoor Unit

Branch Box

Branch Box

Example of Power Multi System using eight indoor units

All Mitsubishi Electric MXZ Multi-Splitmodels have an energy label of ‘A’

Page 21

Page 23: 2008 Product Catalogue

Available in wall and floor mounted, the M Series

range is quiet, economic to

run and easy to install. The outdoor units

can run up to eight indoor units, all

controlled with a simple remote controller.

Whatever your requirements

may be, Mitsubishi Electric

offers the perfect air conditioning

solution for any situation.

ExcellentFeatures

Systems marked with the ECA logo have an energy label of A or B, are registered on theEnergy Technology List and hence qualify for 100% first year enhanced capital allowances(whole system cost and ‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk

Nominal conditions cooling: indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.Nominal conditions heating: indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. Winter; indoor 21˚C DB; outdoor -1˚C WB.

S imple technologyat its best

Page 22

Page 24: 2008 Product Catalogue

MSZ-HC-VA(B) Inverter Heat Pump, Wall Mounted System

MSH-GA-VB Heat Pump, Wall Mounted System

MSZ-GA/GB/GC-VA Inverter Heat Pump, Wall Mounted System

MSZ-FD-VA Inverter Heat Pump, Wall Mounted System

MFZ-KA-VA Inverter Heat Pump, Floor Mounted System

MXZ-A-VA Multi-Split Inverter Heat Pump

MXZ-8A140VA Power Multi Inverter Heat Pump

Outdoor Units

M Series Accessories / Optional Extras

24

26

28

30

32

34

36

50

52

Contents

Page 23

Page 25: 2008 Product Catalogue

MSZ-HC-VA(B) Inverter Heat Pump

Mitsubishi Electric’s new range of high specification, flat panel wall mountedmodels make use of inverter technology, whilst providing extremely goodvalue for money, costing approximately 20% less than the MSZ-G equivalent.

These units have extremely quiet sound levels, whilst also deliveringeconomical air conditioning, with improved COP/EER figures and in many cases corresponding ‘A’ rated energy labels.

* Catechin filter is optional * Air cleaning filter is optional

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Heating/Cooling - Lo-Mi-Hi-SupHi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Heating/Cooling - Lo-Mi-Hi-SupHi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

RUNNING CURRENT (A)

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

MSZ-HC-VA(B) - INDOOR UNITSMSZ-HC25VA

3.2 (0.9-4.4)

2.5 (0.9-3.0)

2.65 (0.75-3.65)

2.5 (0.9-3.0)

0.79

3.64 / 3.25

A / A

5.1-6.5-7.8-9.1 / 5.3-7.0-8.7-10.5

9.52(3/8”)

6.35(1/4”)

26-32-38-43 / 26-32-38-43

788

225

295

9

Fed by Outdoor Unit

Single

0.22

6

4

MSZ-HC35VAB

3.6 (0.9-4.8)

3.4 (1.0-3.7)

3.0 (0.75-4.0)

3.35 (1.0-3.65)

0.76

3.62 / 3.01

A / B

4.9-6.7-8.0-9.2 / 5.2-6.8-8.4-10.2

9.52(3/8”)

6.35(1/4”)

26-32-38-43 / 26-32-38-43

788

225

295

9

Fed by Outdoor Unit

Single

0.22

6

4

MODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. CORES

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 7m

MUZ-HC-VA(B) - OUTDOOR UNITSMUZ-HC25VA

47 / 46

25

684

255

540

220-240v, 50Hz

Single

0.88 / 0.77

0.801 / 0.616

4.2

4.2 / 3.7 [5.5]

16

3

10

5

0.73

MUZ-HC35VAB

48 / 47

25

684

255

540

220-240v, 50Hz

Single

0.995 / 1.13

0.905 / 0.904

5.3

4.8 / 5.3 [6.5]

16

3

10

5

0.75

Technical Information

Page 24

Classic Wall Mounted System

Page 26: 2008 Product Catalogue

MSZ

-HC

-VA

(B)

Inve

rter

Hea

t Pu

mp

INDOOR UNIT MSZ-HC25/35VA(B)

Upper View >

Front View > Side View >

M S

erie

sR

ange

200

8Dimensions

Page 25

Page 27: 2008 Product Catalogue

MSH-GA-VB Heat Pump

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Heating/Cooling - Lo-Mi-Hi-SupHi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Heating/Cooling - Lo-Mi-Hi-SupHi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

RUNNING CURRENT (A)

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

MSH-GA-VB - INDOOR UNITSMSH-GA50VB

5.2

5.0

4.3

4.95

0.65

3.23 / 2.81

C / C

8.8-10.7-12.8 / 8.8-10.7-12.8

12.7(1/2”)

6.35(1/4”)

34-38-42 / 34-38-42

1100

258

325

16

220-240v, 50Hz

Single

0.30

6

2 Core 12v

MSH-GA60VB

7.2

6.3

6.0

6.25

0.64

2.90 / 2.61

D / D

8.8-10.7-12.8 / 9.8-11.2-12.8

15.88(5/8”)

6.35(1/4”)

34-40-45 / 37-41-45

1100

258

325

16

220-240v, 50Hz

Single

0.30

6

2 Core 12v

MODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. CORES

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 7m

MUH-GA-VB - OUTDOOR UNITSMUH-GA50VB

52 / 52

47

850

290

605

220-240v, 50Hz

Single

1.61 / 1.78

1.465 / 1.424

37

7.23 / 7.93 [12.9]

16

3

25

10

1.80

MUH-GA60VB

53 / 53

74

840

330

850

220-240v, 50Hz

Single

2.48 / 2.41

2.257 / 1.928

74

10.70 / 10.39 [16.5]

25

3

25

10

2.35

Notes: MSH-GA50/60VB indoor units require a 240v, 50hz single phase supply and the outdoor units require the same, separate supply. Between the indoor and outdoor unit is a 2 Core, low voltage interconnecting cable.

Technical Information

Page 26

Mitsubishi Electric’s range of high specification, flat panel wallmounted models make use of traditional fixed speed technology,whilst providing extremely good value for money, costingapproximately 30% less than the inverter equivalent.

These units have extremely quiet sound levels, whilst also deliveringeconomical air conditioning. Ideal for use in any size room, both units come equipped with a wide-angle airflow system, as well as an automatic swing vane, allowing airflow to be extended to every corner of a room.

* Air cleaning filter is optional

Classic Wall Mounted System

Page 28: 2008 Product Catalogue

MSH

-GA

-VB

Hea

t Pu

mp

INDOOR UNIT MSH-GA50/60VB

Upper View >

Side View >

Front View >

M S

erie

sR

ange

200

8Dimensions

Page 27

Page 29: 2008 Product Catalogue

MSZ-GA/GB/GC-VA - INDOOR UNITS

MSZ-GA/GB/GC-VA Inverter Heat Pump

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Heating/Cooling - Lo-Mi-Hi-SupHi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Heating/Cooling - Lo-Mi-Hi-SupHi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) – HRC (A)

INTERCONNECTING CABLE No. CORES

MUZ-GA/GB/GC-VA - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/Cooling - Lo-Hi

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) – HRC (A)

MAINS CABLE No. CORES

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 7m

MSZ-GA60VA6.8 (0.9-8.1)

6.0 (0.9-6.7)

5.65 (0.75-6.75)

5.95 (0.9-6.65)

0.79

3.51 / 3.11

B / B

8.7-13.1-17.2 / 8.7-12.8-17.2

15.88 (5/8”)

6.35 (1/4”)

32-40-54

1100

258

325

16

Fed by Outdoor Unit

Single

6

4

MSZ-GA71VA8.1 (0.9-9.6)

7.1 (0.9-8.3)

6.75 (0.75-8.0)

7.05 (0.9-8.25)

0.71

3.31 / 2.93

C / C

9.4-13.6-17.2 / 9.4-13.3-17.2

15.88 (5/8”)

9.52 (3/8”)

33-40-54

1100

258

325

16

Fed by Outdoor Unit

Single

6

4

MSZ-GB50VA5.8 (0.9-7.8)

5.0 (0.9-5.8)

4.8 (0.75-6.5)

4.95 (0.9-5.75)

0.69

3.41 / 3.03

B / B

6.9-7.4-10.9 / 6.9-7.4-10.9

12.7 (1/2”)

6.35 (1/4”)

30-36-42-48 / 32-38-44-48

780

210

298

9

Fed by Outdoor Unit

Single

6

4

MSZ-GC22VA3.3

2.2

2.75

2.2

-

-

-

4.6-6.3-8.0-10.0 / 4.1-5.9-7.7-9.6

9.52 (3/8”)

6.35 (1/4”)

21-29-36-43

788

234

295

9

Fed by Outdoor Unit

Single

6

4

MSZ-GC25VA3.2 (0.9-4.5)

2.5 (0.9-3.0)

2.65 (0.75-3.75)

2.5 (0.9-3.0)

0.79

3.83 / 3.76

A / A

4.6-6.3-8.0-10.0 / 4.1-5.9-7.7-9.6

9.52 (3/8”)

6.35 (1/4”)

21-29-36-43

788

234

295

9

Fed by Outdoor Unit

Single

6

4

MSZ-GC35VA4.0 (0.9-5.0)

3.5 (1.0-3.9)

3.3 (0.75-4.15)

3.45 (1.0-3.85)

0.76

3.79 / 3.26

A / A

4.1-5.6-7.7-9.5 / 3.9-5.5-7.4-9.2

9.52 (3/8”)

6.35 (1/4”)

22-29-36-43

788

234

295

9

Fed by Outdoor Unit

Single

6

4

MUZ-GA60VA

53-55 / 51-53

53

840

330

850

220-240v, 50Hz

1.94 / 1.93

1.77 / 1.54

8.93

8.93 / 8.83 [16]

25

3

30

15

1.8

MUZ-GA71VA

53-55 / 51-53

58

840

330

850

220-240v, 50Hz

2.45 / 2.42

2.23 / 1.94

11.2

11.2 / 11.0 [16]

25

3

30

15

2.0

MUZ-GB50VA

53-55 / 51-52

53

840

330

850

220-240v, 50Hz

1.70 / 1.65

1.55 / 1.32

7.46

7.78 / 7.58 [16]

25

3

30

15

1.5

N/A Multi-Split Only

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

MUZ-GC25VA

47 / 46

26

684

255

540

220-240v, 50Hz

0.835 / 0.665

0.76 / 0.532

4.2

4.2 / 3.6 [5.8]

16

3

20

12

0.75

MUZ-GC35VA

48 / 47

31

800

285

550

220-240v, 50Hz

1.055 / 1.075

0.96 / 0.86

5.0

4.9 / 5.0 [6.5]

16

3

20

12

0.85

Technical Information

Page 28

The MSZ series has been completely redesignedand features the new Catechin filter system.

These models also offer industry leading noise levels and have a distinctively styled front panel that not only looks appealing but also helpsto make cleaning of the unit easier.

Wall Mounted System

* Wide swing & long airflow mode available for MSZ-GA60/71VA * The anti-allergy enzyme filter is optional* Quick clean design available for MSZ-GC22-35/GB50VA

Page 30: 2008 Product Catalogue

MSZ

-GA

/GB/

GC

-VA

Inve

rter

Hea

t Pu

mp

INDOOR UNIT MSZ-GC22-35VA

INDOOR UNIT MSZ-GB50VA

INDOOR UNIT MSZ-GA60/71VA

Front View >Side View >

Upper View >

Front View >

Side View >

Upper View >

Front View >

Side View >

Upper View >

M S

erie

sR

ange

200

8Dimensions

Page 29

Page 31: 2008 Product Catalogue

MSZ-FD-VA - INDOOR UNITS

MSZ-FD-VA Inverter Heat Pump

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Heating/Cooling - Lo-Mi-Hi-SupHi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Heating/Cooling - Lo-Mi-Hi-SupHi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) – HRC (A)

INTERCONNECTING CABLE No. CORES

MUZ-FD-VAH - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) – HRC (A)

MAINS CABLE No. CORES

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 7m

MSZ-FD25VA3.2 (1.5-6.3)

2.5 (1.1-3.5)

2.65 (1.25-5.25)

2.5 (1.1-3.45)

0.85

5.25 / 5.15

A / A

4.5-6.7-9.2-12.1 / 4.6-6.3-8.6-11.2

9.52 (3/8”)

6.35 (1/4”)

20-29-36-43 / 20-29-36-42

798

257

295

12

Fed by Outdoor Unit

Single

6

4

MSZ-FD35VA4.0 (1.3-7.7)

3.5 (0.8-4.0)

3.3 (1.1-6.4)

3.45 (0.8-3.95)

0.85

4.71 / 4.19

A / A

4.7-6.7-9.2-12.5 / 4.6-6.3-8.6-11.2

9.52 (3/8”)

6.35 (1/4”)

21-29-36-44 / 21-29-36-43

798

257

295

12

Fed by Outdoor Unit

Single

6

4

MUZ-FD25VAH

46 / 46

36

800

285

550

220-240v, 50Hz

0.61 / 0.485

0.555 / 0.388

2.9

2.9 / 2.4 [9.2]

16

3

20

12

1.15

MUZ-FD35VAH

50 / 47

36

800

285

550

220-240v, 50Hz

0.85 / 0.835

0.774 / 0.668

3.9

3.9 / 3.8 [10.5]

16

3

20

12

1.15

Technical Information

Page 30

The MSZ-FD series is our most energy efficient M Series wall mounted unit to date. These high COP models feature the new Plasma Duo filter system. These models also offerindustry leading noise levels and have a distinctively styled front panel that not only looks appealing but also helps to make cleaning of the unit easier.

Also incorporated is an ‘I-See Sensor’, providing even temperaturedistribution and further reducing energy consumption.

Wall Mounted System

Page 32: 2008 Product Catalogue

MSZ

-FD

-VA

Inve

rter

Hea

t Pu

mp

INDOOR UNIT MSZ-FD25/35VA

Front View > Side View >

Upper View >

M S

erie

sR

ange

200

8Dimensions

Page 31

Page 33: 2008 Product Catalogue

MFZ-KA-VA - INDOOR UNITS

MFZ-KA-VA Inverter Heat Pump

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Heating/Cooling - Lo-Mi-Hi-SupHi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Heating/Cooling - Lo-Mi-Hi-SupHi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) – HRC (A)

INTERCONNECTING CABLE No. CORES

SUZ-KA-VA - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. CORES

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 7m

MFZ-KA25VA

3.4 (0.9-5.1)

2.5 (0.9-3.4)

2.85 (0.75-4.25)

2.5 (0.9-3.35)

0.66

4.07 / 4.31

A / A

5.0-6.2-7.6-9.1 / 4.8-5.8-7.1-8.7

9.52 (3/8”)

6.35 (1/4”)

22-27-32-37 / 22-27-32-37

700

200

600

14

Fed by Outdoor Unit

Single

6

4

MFZ-KA35VA

4.0 (0.9-6.2)

3.5 (0.9-3.9)

3.3 (0.75-5.15)

3.45 (0.9-3.85)

0.65

3.64 / 3.21

A / A

5.2-6.2-7.8-9.5 / 5.0-6.1-7.4-9.1

9.52 (3/8”)

6.35 (1/4”)

25-28-33-38 / 23-28-33-38

700

200

600

14

Fed by Outdoor Unit

Single

6

4

MFZ-KA50VA

6.0 (0.9-7.9)

4.8 (0.9-5.4)

5.0 (0.75-6.55)

4.75 (0.9-5.35)

0.63

3.23 / 3.10

C / B

7.4-8.8-9.8-11.8 / 7.1-7.9-9.2-10.7

12.7 (1/2”)

6.35 (1/4”)

32-35-39-44 / 32-35-39-43

700

200

600

14

Fed by Outdoor Unit

Single

6

4

SUZ-KA25VA

46 / 46

33

800

285

550

220-240v, 50Hz

0.835 / 0.58

0.76 / 0.46

3.8

4.0 / 2.8 [9.2]

16

3

20

12

0.9

SUZ-KA35VA

48 / 47

37

800

285

550

220-240v, 50Hz

1.10 / 1.09

1.00 / 0.87

4.8

5.0 / 5.0 [10.3]

16

3

20

12

1.05

SUZ-KA50VA

55 / 53

53

840

330

850

220-240v, 50Hz

1.86 / 1.55

1.69 / 1.24

8.3

8.5 / 7.0 [17.8]

25

3

30

15

1.6

Technical Information

Page 32

The MFZ-KA-VA series is extremely versatile and isdesigned for wall attached installation at floor level.The auto swing vane provides a more natural andcomfortable airflow throughout the room and the lightweight, compact design makes installation easy.

Floor Mounted System

Page 34: 2008 Product Catalogue

MFZ

-KA

-VA

Inve

rter

Hea

t Pu

mp

INDOOR UNIT MFZ-KA25-50VA

Front View >

Upper View >

Side View >M

Ser

ies

Ran

ge 2

008Dimensions

Page 33

Page 35: 2008 Product Catalogue

MXZ-A-VA - OUTDOOR UNITS

MXZ-A-VA Inverter Heat Pump (5.2 - 10.0kW)

MODEL REFERENCE

NUMBER OF CONNECTABLE INDOOR UNITS

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

MAX AIRFLOW (m3/min) Heating/Cooling

NOISE (dBA) Heating/Cooling - Lo-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

RUNNING CURRENT (A) [MAX] Heating/Cooling

INTERCONNECTING CABLE No. CORES

TOTAL PIPE LENGTH (m)

MAX PIPE LENGTH PER INDOOR UNIT (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 40m (20m for MXZ-2A52VA)

FUSE RATING (BS88) – HRC (A)

MXZ-3A54VA

2 - 3

6.8 (2.6-9.0)

5.4 (2.9-6.8)

5.65 (2.15-7.5)

5.35 (2.9-6.75)

4.67 / 4.17

A / A

41.2 / 42.1

47-48 / 44-46

840

330

710

57

220-240v, 50Hz

1.455 / 1.295

1.32 / 1.04

6.39

6.39 / 5.69 [16.4]

4 Core

50

25

15 (10 if Outdoor higher than Indoor)

2.7

25

MXZ-4A71VA

2 - 4

8.6 (3.4-9.0)

7.1 (3.7-8.8)

7.15 (2.85-7.5)

7.05 (3.65-8.75)

4.41 / 3.68

A / A

46.5 / 42.1

48-50 / 45-48

840

330

710

58

220-240v, 50Hz

1.95 / 1.93

1.77 / 1.54

8.56

8.56 / 8.48 [16.4]

4 Core

60

25

15 (10 if Outdoor higher than Indoor)

2.7

25

MXZ-5A100VA

2 - 5

12.0 (3.4-14.0)

10.0 (3.7-11.0)

9.95 (2.85-11.65)

9.9 (3.65-10.9)

4.23 / 3.41

A / A

59.3 / 56.6

46-54 / 45-51

900

320

900

68

220-240v, 50Hz

2.835 / 2.935

2.58 / 2.35

12.88

12.45 / 12.88 [19.4]

4 Core

80

25

15 (10 if Outdoor higher than Indoor)

4.0

25

MXZ-2A52VA

2

6.4 (1.0-7.2)

5.2 (1.1-6.0)

5.3 (0.85-6.0)

5.15 (1.1-5.95)

3.75 / 3.46

A / A

31 / 31

48-50 / 45-49

800

285

550

40

220-240v, 50Hz

1.705 / 1.505

1.55 / 1.2

7.64

7.64 / 6.75 [10.2]

4 Core

30

20

15 (10 if Outdoor higher than Indoor)

1.3

16

MXZ-4A80VA

2 - 4

9.4 (3.4-11.6)

8.0 (3.7-9.2)

7.8 (2.85-9.65)

7.95 (3.65-9.15)

4.87 / 3.65

A / A

43.8 / 42.2

46-48 / 44-46

900

320

900

67

220-240v, 50Hz

1.93 / 2.19

1.76 / 1.75

9.62

8.48 / 9.62 [17.4]

4 Core

70

25

15 (10 if Outdoor higher than Indoor)

3.5

25

MULTI-SPLIT - INDOOR UNITSMODEL REFERENCE

MSZ-GC22/25/35VAMSZ-GB50VA

MSZ-FD25/35VAMFZ-KA25/35/50VA

SEZ-KD25/35/50VAPEAD-RP50EA

SLZ-KA25/35/50VAPLA-RP50BA

PCA-RP50GA2MXZ-3A54VA

MSZ-GC22/25/35VAMSZ-FD25/35VA

MFZ-KA25/35VA SEZ-KD25/35VA SLZ-KA25/35VAMXZ-2A52VA

MSZ-GC22/25/35VAMSZ-GB50VAMSZ-GA60VA

MSZ-FD25/35VA

MFZ-KA25/35/50VASEZ-KD25/35/50/60VA

PEAD-RP50EASLZ-KA25/35/50VA

PLA-RP50/60BAPCA-RP50/60GA(2)MXZ-4A71VA

MSZ-GC22/25/35VAMSZ-GB50VA

MSZ-GA60/71VAMSZ-FD25/35VA

MFZ-KA25/35/50VASEZ-KD25/35/50/60/71VA

PEAD-RP50EASLZ-KA25/35/50VAPLA-RP50/60/71BA

PCA-RP50/60/71GA(2)MXZ-4A80VA

MSZ-GC22/25/35VAMSZ-GB50VA

MSZ-GA60/71VAMSZ-FD25/35VA

MFZ-KA25/35/50VASEZ-KD25/35/50/60/71VA

PEAD-RP50EASLZ-KA25/35/50VAPLA-RP50/60/71BA

PCA-RP50/60/71GA(2)MXZ-5A100VA

WALL MOUNTED FLOOR MOUNTED DUCTED CEILING CASSETTE CEILING SUSPENDED

� Up to five indoor units may be connected to a single outdoor unit

� Energy saving inverter controlled outdoor unit adjusts compressor performance to economically match the demand for heating and cooling

� Units may be added within the capacity of the system as requirements change

� Single outdoor unit for minimal noise and space impact

� Capacities of indoor units may be mixed to suit individual rooms

Technical Information

Page 34

The multi-split system allows up to five M Series or Mr Slim wall mounted,cassette, ducted, floor or ceiling mounted indoor unit heat-pumps of differentcapacities to be operated from a single outdoor unit. This makes it an economicanswer in multi-room applications, whilst also offering space saving benefits.

Multi-Split Units

Page 36: 2008 Product Catalogue

MX

Z-A

-VA

M

ulti-

Split

Inve

rter

Hea

t Pu

mp

(5.2

-10.

0kW

)

OUTDOOR UNIT MXZ-2A52VA

Front View > Side View >Upper View >

OUTDOOR UNIT MXZ-3A54VA / MXZ-4A71VA

Front View > Side View >Upper View >

D connection for MXZ-4A71VA

OUTDOOR UNIT MXZ-4A80VA / MXZ-5A100VA

Front View > Side View >Upper View >

E connection for MXZ-5A100VA

M S

erie

sR

ange

200

8Dimensions

Page 35

Page 37: 2008 Product Catalogue

MXZ-8A140VA - OUTDOOR UNIT

MXZ-8A140VA Power Multi (14kW)

MODEL REFERENCE

NUMBER OF CONNECTABLE INDOOR UNITS

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

MAX AIRFLOW (m3/min)

NOISE (dBA) Lo-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

RUNNING CURRENT (A) [MAX] Heating/Cooling

INTERCONNECTING CABLE No. CORES

TOTAL PIPE LENGTH (m)

MAX PIPE LENGTH PER INDOOR UNIT (m)

FURTHEST PIPE LENGTH - Outdoor to Indoor (m)

MAX HEIGHT DIFFERENCE - Outdoor to Indoor (m)

MAX HEIGHT DIFFERENCE - Indoor to Indoor (m)

CHARGE R410A (kg) - 40m

FUSE RATING (BS88) – HRC (A)

MXZ-8A140VA

2 - 8

16.0

14.0

13.3

13.9

4.10 / 3.69

A / A

100

52 / 50

950

330 (+30)

1350

128

220-240v, 50Hz

3.90 / 3.79

3.55 / 3.03

14

16.33 / 15.86 [29.5]

4 Core

115

15 (from Branch Box)

70

30 (20 if Outdoor lower than Indoor)

12

8.5

40

PAC-AK30BC

1 - 3

From Outdoor Unit

From Branch Box

15.88(5/8”)

9.52(3/8”)

55

60

30

15

450

280

198

PAC-AK30BC - BRANCH BOXMODEL REFERENCE

NUMBER OF CONNECTABLE INDOOR UNITS

POWER SUPPLY TO BRANCH BOX

POWER SUPPLY TO INDOOR UNITS

PIPE SIZE mm(in) Main Outdoor Side - Gas

PIPE SIZE mm(in) Main Outdoor Side - Liquid

MAX PIPE LENGTH - Outdoor Unit to Branch Box (m)

TOTAL PIPE LENGTH - Branch Boxes to Indoor Unit (m)

MAX HEIGHT DIFFERENCE - Outdoor Unit to Branch Box (m)

MAX HEIGHT DIFFERENCE - Branch Box to Indoor Unit (m)

DIMENSIONS (mm) Width

Depth

Height

PAC-AK50BC

1 - 5

From Outdoor Unit

From Branch Box

15.88(5/8”)

9.52(3/8”)

55

60

30

15

450

280

198

PAC-AK50BC - BRANCH BOXMODEL REFERENCE

NUMBER OF CONNECTABLE INDOOR UNITS

POWER SUPPLY TO BRANCH BOX

POWER SUPPLY TO INDOOR UNITS

PIPE SIZE mm(in) Main Outdoor Side - Gas

PIPE SIZE mm(in) Main Outdoor Side - Liquid

MAX PIPE LENGTH - Outdoor Unit to Branch Box (m)

TOTAL PIPE LENGTH - Branch Boxes to Indoor Unit (m)

MAX HEIGHT DIFFERENCE - Outdoor Unit to Branch Box (m)

MAX HEIGHT DIFFERENCE - Branch Box to Indoor Unit (m)

DIMENSIONS (mm) Width

Depth

Height

MULTI-SPLIT - INDOOR UNITSMODEL REFERENCE

MSZ-GC22/25/35VA

MSZ-GB50VA

MSZ-GA60/71VA

MSZ-FD25/35VA

MFZ-KA25/35/50VASEZ-KD25/35/50/60/71VA

PEAD-RP50/60/71EA

SLZ-KA25/35/50VA

PLA-RP35/50/60/71BA(2)MXZ-8A140VA

WALL MOUNTED FLOOR MOUNTED DUCTED CEILING CASSETTE

� 14kW Inverter Multi System, based on Mr Slim Power Inverter technology

� Total Pipe length of 115m / Height difference of 30m

� Individual control of each indoor unit is now possible (ON/OFF & Setpoint)

� Low starting and running currents

� Connection to M-NET system via MAC-399IF interface (one per indoor unit)

� New Centralised Simple ON/OFF remote controller MAC-821SC-E available to control up to 8 indoor units (interface MAC-397IF is needed, one per indoor unit)

Technical Information

Page 36

The Power Multi system allows up to eight M Series or Mr Slim cassette, ducted,floor, ceiling or wall mounted indoor units of different capacities to be operatedfrom a single outdoor unit, making use of two types of branch box to achievethis. This makes it an economic answer in multi-room applications and ideal forapartments or small commercial buildings.

Inverter Heat Pump Multi-Split Unit

Page 38: 2008 Product Catalogue

MX

Z-8

A14

0VA

Pow

er M

ulti

Inve

rter

Hea

t Pu

mp

(14k

W)

OUTDOOR UNIT MXZ-8A140VA

Front View > Side View >

Front View > Side View >

Upper View >

Upper View >

Front View > Side View > Upper View >

BRANCH BOX PAC-AK30BC

BRANCH BOX PAC-AK50BC

M S

erie

sR

ange

200

8Dimensions

Page 37

Page 39: 2008 Product Catalogue

MSZ-GA/GB/GC-VA Series

MFZ-KA-VA Series SEZ-KD-VA Series

MXZ-3A54/4A71VAInverter Multi units

MXZ-4A80/5A100VA Inverter Multi units

6Outdoor Units

30Indoor Units

MXZ-8A140VA Power Multi unit

PLA-RP-BA(2) Series

PCA-RP-GA(2) Series

SLZ-KA-VA Series

PEAD-RP-EA Series

Inverter Multi-Split Systems

MXZ-2A52VA Inverter Multi unit

MSZ-FD-VA Series

Page 38

Page 40: 2008 Product Catalogue

Multi-Split systems allow up to eight M Series or Mr Slim cassette, ducted, floor, ceiling or wall mounted indoor units of different capacities to be operated from a single outdoor unit

Page 41: 2008 Product Catalogue

1 ROOM22

25

35

2 ROOMS22 + 22

22 + 25

22 + 35

25 + 25

25 + 35

35 + 35

Indoor unitcombination Cooling / Heating Capacity (kW)

Unit A

2.20 / 3.30

2.50 / 3.60

3.50 / 4.00

2.20 / 3.05

2.20 / 2.90

1.93 / 2.43

2.50 / 3.15

2.13 / 2.63

2.60 / 3.20

Unit B

2.20 / 3.05

2.50 / 3.30

3.07 / 3.87

2.50 / 3.15

2.97 / 3.67

2.60 / 3.20

Unit C

MXZ-2A52VA1Outdoor Unit 2 Indoor Units

MXZ-4A71VA1Outdoor Unit Up to 4 Indoor Units

1 ROOM22

25

35

50

60

2 ROOMS22 + 22

22 + 25

22 + 35

22 + 50

22 + 60

25 + 25

25 + 35

25 + 50

25 + 60

35 + 35

35 + 50

35 + 60

50 + 50

50 + 60

60 + 60

3 ROOMS22 + 22 + 22

22 + 22 + 25

22 + 22 + 35

22 + 22 + 50

22 + 22 + 60

22 + 25 + 25

22 + 25 + 35

22 + 25 + 50

22 + 25 + 60

22 + 35 + 35

22 + 35 + 50

22 + 35 + 60

22 + 50 + 50

25 + 25 + 25

25 + 25 + 35

25 + 25 + 50

25 + 25 + 60

25 + 35 + 35

25 + 35 + 50

25 + 35 + 60

25 + 50 + 50

35 + 35 + 35

35 + 35 + 50

Unit A

2.20 / 3.30

2.50 / 3.60

3.50 / 4.00

5.00 / 7.20

6.00 / 7.90

2.20 / 3.30

2.20 / 3.23

2.20 / 2.82

2.08 / 2.63

1.82 / 2.31

2.50 / 3.60

2.50 / 3.17

2.27 / 2.87

2.00 / 2.53

3.40 / 4.30

2.80 / 3.54

2.51 / 3.17

3.40 / 4.30

3.09 / 3.91

3.40 / 4.30

2.20 / 2.87

2.20 / 2.74

1.98 / 2.39

1.66 / 2.01

1.50 / 1.82

2.16 / 2.62

1.91 / 2.31

1.61 / 1.95

1.46 / 1.77

1.70 / 2.06

1.46 / 1.77

1.34 / 1.62

1.28 / 1.56

2.36 / 2.86

2.09 / 2.53

1.78 / 2.15

1.61 / 1.95

1.86 / 2.26

1.61 / 1.95

1.48 / 1.79

1.42 / 1.72

2.36 / 2.86

2.07 / 2.51

Unit B

2.20 / 3.30

2.50 / 3.67

3.50 / 4.48

4.72 / 5.97

4.98 / 6.29

2.50 / 3.60

3.50 / 4.43

4.53 / 5.73

4.80 / 6.07

3.40 / 4.30

4.00 / 5.06

4.29 / 5.43

3.40 / 4.30

3.71 / 4.69

3.40 / 4.30

2.20 / 2.87

2.20 / 2.74

1.98 / 2.39

1.66 / 2.01

1.50 / 1.82

2.47 / 2.99

2.16 / 2.62

1.83 / 2.22

1.66 / 2.01

2.70 / 3.27

2.32 / 2.81

2.12 / 2.57

2.91 / 3.52

2.36 / 2.86

2.09 / 2.53

1.78 / 2.15

1.61 / 1.95

2.62 / 3.17

2.26 / 2.74

2.07 / 2.51

2.84 / 3.44

2.36 / 2.86

2.07 / 2.51

Unit C

2.20 / 2.87

2.50 / 3.12

3.14 / 3.82

3.78 / 4.58

4.10 / 4.96

2.47 / 2.99

3.03 / 3.67

3.66 / 4.43

3.98 / 4.82

2.70 / 3.27

3.32 / 4.02

3.64 / 4.41

2.91 / 3.52

2.36 / 2.86

2.92 / 3.54

3.54 / 4.30

3.88 / 4.68

2.62 / 3.17

3.23 / 3.91

3.55 / 4.30

2.84 / 3.44

2.36 / 2.86

2.96 / 3.58

Unit D

Indoor unitcombination

Cooling / Heating Capacity (kW)

Inverter Multi-Split System Combinations

1 ROOM22

25

35

50

2 ROOMS22 + 22

22 + 25

22 + 35

22 + 50

25 + 25

25 + 35

25 + 50

35 + 35

35 + 50

50 + 50

3 ROOMS22 + 22 + 22

22 + 22 + 25

22 + 22 + 35

22 + 22 + 50

22 + 25 + 25

22 + 25 + 35

22 + 25 + 50

22 + 35 + 35

25 + 25 + 25

25 + 25 + 35

25 + 25 + 50

25 + 35 + 35

Indoor unitcombination

Cooling / Heating Capacity (kW)

Unit A

2.20 / 3.30

2.50 / 3.60

3.50 / 4.00

5.00 / 6.80

2.20 / 3.30

2.20 / 3.18

2.08 / 2.62

1.65 / 2.08

2.50 / 3.40

2.25 / 2.83

1.80 / 2.27

2.70 / 3.40

2.22 / 2.80

2.70 / 3.40

1.80 / 2.27

1.72 / 2.17

1.50 / 1.89

1.26 / 1.59

1.64 / 2.08

1.45 / 1.83

1.23 / 1.54

1.30 / 1.62

1.80 / 2.27

1.59 / 2.00

1.35 / 1.70

1.42 / 1.78

Unit B

2.20 / 3.30

2.50 / 3.62

3.32 / 4.18

3.75 / 4.72

2.50 / 3.40

3.15 / 3.97

3.60 / 4.53

2.70 / 3.40

3.18 / 4.00

2.70 / 3.40

1.80 / 2.27

1.72 / 2.17

1.50 / 1.89

1.26 / 1.59

1.88 / 2.36

1.65 / 2.07

1.39 / 1.75

2.05 / 2.59

1.80 / 2.27

1.59 / 2.00

1.35 / 1.70

1.99 / 2.51

Unit C

1.80 / 2.27

1.96 / 2.46

2.40 / 3.02

2.88 / 3.62

1.88 / 2.36

2.30 / 2.90

2.78 / 3.51

2.05 / 2.59

1.80 / 2.27

2.22 / 2.80

2.70 / 3.40

1.99 / 2.51

MXZ-3A54VA1Outdoor Unit Up to 3 Indoor Units

Page 40

Page 42: 2008 Product Catalogue

1 ROOM22

25

35

50

60

71

2 ROOMS22 + 22

22 + 25

22 + 35

22 + 50

22 + 60

22 + 71

25 + 25

25 + 35

25 + 50

25 + 60

25 + 71

35 + 35

35 + 50

Unit A

2.20 / 3.30

2.50 / 3.60

3.50 / 4.00

5.00 / 7.20

6.00 / 7.90

7.10 / 8.60

2.20 / 3.30

2.20 / 3.23

2.20 / 2.82

2.20 / 2.72

1.75 / 2.52

1.66 / 2.22

2.50 / 3.60

2.50 / 3.17

2.50 / 3.00

2.11 / 2.76

2.01 / 2.42

3.50 / 4.00

3.10 / 3.87

Unit B

2.20 / 3.30

2.50 / 3.67

3.50 / 4.48

5.00 / 6.20

6.00 / 6.88

6.19 / 7.18

2.50 / 3.60

3.50 / 4.43

5.00 / 6.00

5.64 / 6.64

5.84 / 6.98

3.50 / 4.00

4.65 / 5.53

Unit C Unit D

Indoor unitcombination

Cooling / Heating Capacity (kW)

MXZ-4A80VA1Outdoor Unit Up to 4 Indoor Units

35 + 60

35 + 71

50 + 50

50 + 60

50 + 71

60 + 60

60 + 71

3 ROOMS

22 + 22 + 22

22 + 22 + 25

22 + 22 + 35

22 + 22 + 50

22 + 22 + 60

22 + 22 + 71

22 + 25 + 25

22 + 25 + 35

22 + 25 + 50

22 + 25 + 60

22 + 25 + 71

22 + 35 + 35

22 + 35 + 50

22 + 35 + 60

22 + 35 + 71

22 + 50 + 50

22 + 50 + 60

22 + 50 + 71

25 + 25 + 25

25 + 25 + 35

25 + 25 + 50

25 + 25 + 60

25 + 25 + 71

25 + 35 + 35

25 + 35 + 50

25 + 35 + 60

25 + 35 + 71

25 + 50 + 50

25 + 50 + 60

35 + 35 + 35

35 + 35 + 50

35 + 35 + 60

35 + 35 + 71

35 + 50 + 50

35 + 50 + 60

Unit A

2.61 / 3.46

2.51 / 3.10

3.95 / 4.70

3.42 / 4.27

3.27 / 3.88

4.00 / 4.70

3.84 / 4.31

2.20 / 2.90

2.20 / 2.84

2.14 / 2.62

1.72 / 2.20

1.46 / 1.99

1.40 / 1.80

2.20 / 2.72

2.08 / 2.52

1.79 / 2.13

1.64 / 1.93

1.49 / 1.75

1.87 / 2.25

1.63 / 1.93

1.50 / 1.77

1.38 / 1.62

1.44 / 1.70

1.33 / 1.57

1.23 / 1.45

2.50 / 3.00

2.28 / 2.76

1.98 / 2.35

1.82 / 2.14

1.65 / 1.94

2.07 / 2.48

1.82 / 2.14

1.67 / 1.96

1.53 / 1.79

1.60 / 1.88

1.48 / 1.74

2.65 / 3.13

2.33 / 2.74

2.15 / 2.53

1.99 / 2.33

2.08 / 2.44

1.93 / 2.27

Unit B

5.24 / 5.94

5.44 / 6.30

3.95 / 4.70

4.57 / 5.13

4.72 / 5.52

4.00 / 4.70

4.16 / 5.09

2.20 / 2.90

2.20 / 2.81

2.14 / 2.62

1.72 / 2.20

1.46 / 1.99

1.40 / 1.80

2.50 / 3.09

2.36 / 2.87

2.04 / 2.42

1.87 / 2.20

1.69 / 1.99

2.99 / 3.58

2.58 / 3.07

2.40 / 2.81

2.18 / 2.57

3.28 / 3.85

3.03 / 3.56

2.80 / 3.29

2.50 / 3.00

2.28 / 2.76

1.98 / 2.35

1.82 / 2.14

1.65 / 1.94

2.89 / 3.46

2.54 / 2.99

2.33 / 2.74

2.14 / 2.51

3.20 / 3.76

2.96 / 3.48

2.65 / 3.13

2.33 / 2.74

2.15 / 2.53

1.99 / 2.33

2.96 / 3.48

2.76 / 3.24

Unit C

2.20 / 2.90

2.50 / 3.19

3.42 / 4.16

4.41 / 5.00

5.03 / 5.42

5.20 / 5.80

2.50 / 3.09

3.31 / 4.01

4.07 / 4.85

4.49 / 5.27

4.82 / 5.66

2.99 / 3.58

3.69 / 4.39

4.1 / 4.82

4.44 / 5.21

3.28 / 3.85

3.64 / 4.27

3.97 / 4.67

2.50 / 3.00

3.19 / 3.87

3.94 / 4.70

4.36 / 5.13

4.70 / 5.52

2.89 / 3.46

3.64 / 4.27

4.00 / 4.70

4.33 / 5.09

3.20 / 3.76

3.56 / 4.18

2.65 / 3.13

3.34 / 3.92

3.70 / 4.34

4.02 / 4.74

2.96 / 3.48

3.31 / 3.89

Unit D

Indoor unitcombination

Cooling / Heating Capacity (kW)

4 ROOMS22 + 22 + 22 + 22

22 + 22 + 22 + 25

22 + 22 + 22 + 35

22 + 22 + 22 + 50

22 + 22 + 25 + 25

22 + 22 + 25 + 35

22 + 22 + 25 + 50

22 + 22 + 35 + 35

22 + 25 + 25 + 25

22 + 25 + 25 + 35

22 + 25 + 25 + 50

22 + 25 + 35 + 35

25 + 25 + 25 + 25

25 + 25 + 25 + 35

25 + 25 + 25 + 50

25 + 25 + 35 + 35

Unit A

1.77 / 2.15

1.72 / 2.08

1.55 / 1.87

1.35 / 1.63

1.66 / 2.01

1.50 / 1.82

1.31 / 1.59

1.37 / 1.66

1.61 / 1.94

1.46 / 1.77

1.29 / 1.56

1.34 / 1.62

1.77 / 2.15

1.61 / 1.95

1.42 / 1.72

1.48 / 1.79

Unit B

1.77 / 2.15

1.72 / 2.08

1.55 / 1.87

1.35 / 1.63

1.66 / 2.01

1.50 / 1.82

1.31 / 1.59

1.37 / 1.66

1.83 / 2.22

1.66 / 2.01

1.45 / 1.76

1.52 / 1.84

1.77 / 2.15

1.61 / 1.95

1.42 / 1.72

1.48 / 1.79

Unit C

1.77 / 2.15

1.72 / 2.08

1.55 / 1.87

1.35 / 1.63

1.89 / 2.29

1.71 / 2.07

1.50 / 1.81

2.18 / 2.64

1.83 / 2.22

1.66 / 2.01

1.45 / 1.76

2.12 / 2.57

1.77 / 2.15

1.61 / 1.95

1.42 / 1.72

2.07 / 2.51

Unit D

1.77 / 2.15

1.94 / 2.36

2.45 / 2.98

3.05 / 3.71

1.89 / 2.29

2.39 / 2.89

2.98 / 3.61

2.18 / 2.64

1.83 / 2.22

2.32 / 2.81

2.91 / 3.52

2.12 / 2.57

1.77 / 2.15

2.27 / 2.75

2.84 / 3.44

2.07 / 2.51

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 41

Page 43: 2008 Product Catalogue

4 ROOMS22 + 22 + 22 + 22

22 + 22 + 22 + 25

22 + 22 + 22 + 35

22 + 22 + 22 + 50

22 + 22 + 22 + 60

22 + 22 + 22 + 71

22 + 22 + 25 + 25

22 + 22 + 25 + 35

22 + 22 + 25 + 50

22 + 22 + 25 + 60

22 + 22 + 25 + 71

22 + 22 + 35 + 35

22 + 22 + 35 + 50

22 + 22 + 35 + 60

22 + 22 + 50 + 50

22 + 25 + 25 + 25

22 + 25 + 25 + 35

22 + 25 + 25 + 50

22 + 25 + 25 + 60

22 + 25 + 35 + 35

22 + 25 + 35 + 50

22 + 25 + 35 + 60

22 + 35 + 35 + 35

22 + 35 + 35 + 50

25 + 25 + 25 + 25

25 + 25 + 25 + 35

25 + 25 + 25 + 50

25 + 25 + 25 + 60

25 + 25 + 35 + 35

25 + 25 + 35 + 50

25 + 35 + 35 + 35

35 + 35 + 35 + 35

Unit A

1.95 / 2.35

1.90 / 2.27

1.73 / 2.05

1.52 / 1.78

1.40 / 1.64

1.28 / 1.51

1.87 / 2.20

1.68 / 1.99

1.48 / 1.74

1.36 / 1.60

1.26 / 1.48

1.54 / 1.81

1.36 / 1.60

1.12 / 1.49

1.22 / 1.44

1.78 / 2.14

1.63 / 1.93

1.44 / 1.70

1.33 / 1.57

1.51 / 1.77

1.33 / 1.57

1.24 / 1.46

1.40 / 1.63

1.24 / 1.45

1.98 / 2.35

1.82 / 2.14

1.60 / 1.88

1.48 / 1.74

1.67 / 1.96

1.48 / 1.74

1.55 / 1.81

2.00 / 2.35

Unit B

1.95 / 2.35

1.90 / 2.27

1.73 / 2.05

1.52 / 1.78

1.40 / 1.64

1.28 / 1.51

1.87 / 2.20

1.68 / 1.99

1.48 / 1.74

1.36 / 1.60

1.26 / 1.48

1.54 / 1.81

1.36 / 1.60

1.12 / 1.49

1.22 / 1.44

2.04 / 2.42

1.86 / 2.20

1.64 / 1.93

1.52 / 1.78

1.71 / 2.01

1.52 / 1.78

1.41 / 1.65

2.20 / 2.59

1.97 / 2.32

1.98 / 2.35

1.82 / 2.14

1.60 / 1.88

1.48 / 1.74

1.67 / 1.96

1.48 / 1.74

2.15 / 2.53

2.00 / 2.35

Unit C

1.95 / 2.35

1.90 / 2.27

1.73 / 2.05

1.52 / 1.78

1.40 / 1.64

1.28 / 1.51

2.13 / 2.50

1.91 / 2.26

1.68 / 1.97

1.55 / 1.83

1.43 / 1.68

2.46 / 2.89

2.18 / 2.55

1.92 / 2.37

2.78 / 3.26

2.04 / 2.42

1.86 / 2.20

1.64 / 1.93

1.52 / 1.78

2.39 / 2.81

2.12 / 2.49

1.97 / 2.32

2.20 / 2.59

1.97 / 2.32

1.98 / 2.35

1.82 / 2.14

1.60 / 1.88

1.48 / 1.74

2.33 / 2.74

2.08 / 2.44

2.15 / 2.53

2.00 / 2.35

Unit D

1.95 / 2.35

2.15 / 2.59

2.76 / 3.25

3.44 / 4.06

3.81 / 4.48

4.16 / 4.87

2.13 / 2.50

1.91 / 3.16

3.36 / 3.95

3.73 / 4.37

4.05 / 4.76

2.46 / 2.89

3.10 / 3.65

3.84 / 4.05

2.78 / 3.26

2.04 / 2.42

2.60 / 3.07

3.28 / 3.85

3.64 / 4.27

2.39 / 2.81

3.03 / 3.56

3.38 / 3.97

2.20 / 2.59

2.82 / 3.31

1.98 / 2.35

2.54 / 2.98

3.20 / 3.76

3.56 / 4.18

2.33 / 2.74

2.96 / 3.48

2.15 / 2.53

2.00 / 2.35

Indoor unitcombination

Cooling / Heating Capacity (kW)

1 ROOM22

25

35

50

60

71

Unit A

2.20 / 3.30

2.50 / 3.60

3.50 / 4.00

5.00 / 7.20

6.00 / 7.90

7.10 / 8.60

Unit B Unit C Unit D

Indoor unitcombination Cooling / Heating Capacity (kW)

MXZ-5A100VA1Outdoor Unit Up to 5 Indoor Units

2 ROOMS22 + 22

22 + 25

22 + 35

22 + 50

22 + 60

22 + 71

25 + 25

25 + 35

25 + 50

25 + 60

25 + 71

35 + 35

35 + 50

35 + 60

35 + 71

50 + 50

50 + 60

50 + 71

60 + 60

60 + 71

71 + 71

3 ROOMS

22 + 22 + 22

22 + 22 + 25

22 + 22 + 35

22 + 22 + 50

22 + 22 + 60

22 + 22 + 71

22 + 25 + 25

22 + 25 + 35

22 + 25 + 50

22 + 25 + 60

22 + 25 + 71

22 + 35 + 35

22 + 35 + 50

22 + 35 + 60

22 + 35 + 71

22 + 50 + 50

22 + 50 + 60

22 + 50 + 71

22 + 60 + 60

22 + 60 + 71

Unit A

2.20 / 3.30

2.20 / 3.23

2.20 / 2.82

2.20 / 2.72

2.08 / 2.52

1.86 / 2.22

2.50 / 3.60

2.50 / 3.17

2.50 / 3.00

2.28 / 2.94

2.04 / 2.60

3.50 / 4.00

3.19 / 4.12

2.89 / 3.68

2.62 / 3.30

3.95 / 5.00

3.64 / 4.55

3.43 / 4.13

4.15 / 5.00

3.89 / 4.58

4.40 / 5.00

2.20 / 2.90

2.20 / 2.80

2.14 / 2.78

1.84 / 2.57

1.68 / 2.33

1.53 / 2.10

2.20 / 2.72

2.08 / 2.68

1.79 / 2.49

1.64 / 2.26

1.49 / 2.05

1.87 / 2.40

1.63 / 2.26

1.50 / 2.07

1.46 / 1.89

1.50 / 1.98

1.42 / 1.83

1.38 / 1.69

1.40 / 1.70

1.29 / 1.58

Unit B

2.20 / 3.30

2.50 / 3.67

3.50 / 4.48

5.00 / 6.18

5.67 / 6.88

5.99 / 7.18

2.50 / 3.60

3.50 / 4.43

5.00 / 6.00

5.47 / 7.06

5.81 / 7.40

3.50 / 4.00

4.56 / 5.88

4.96 / 6.32

5.33 / 6.70

3.95 / 5.00

4.36 / 5.45

4.87 / 5.87

4.15 / 5.00

4.61 / 5.42

4.40 / 5.00

2.20 / 2.90

2.20 / 2.81

2.14 / 2.78

1.84 / 2.57

1.68 / 2.33

1.53 / 2.10

2.50 / 3.09

2.36 / 3.05

2.04 / 2.84

1.87 / 2.57

1.69 / 2.33

2.99 / 3.80

2.58 / 3.60

2.40 / 3.29

2.32 / 3.01

3.40 / 4.51

3.22 / 4.17

3.15 / 3.85

3.80 / 4.65

3.53 / 4.31

Unit C

2.20 / 2.90

2.50 / 3.19

3.42 / 4.44

4.17 / 5.86

4.59 / 6.35

4.94 / 6.80

2.50 / 3.09

3.31 / 4.27

4.07 / 5.67

4.49 / 6.17

4.82 / 6.62

2.99 / 3.80

3.69 / 5.14

4.1 / 5.64

4.72 / 6.10

3.40 / 4.51

3.86 / 5.00

4.47 / 5.46

3.80 / 4.65

4.18 / 5.11

Unit D

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 42

Page 44: 2008 Product Catalogue

22 + 22 + 35 + 71

22 + 22 + 50 + 50

22 + 22 + 50 + 60

22 + 22 + 50 + 71

22 + 25 + 25 + 25

22 + 25 + 25 + 35

22 + 25 + 25 + 50

22 + 25 + 25 + 60

22 + 25 + 25 + 71

22 + 25 + 35 + 35

22 + 25 + 35 + 50

22 + 25 + 35 + 60

22 + 25 + 35 + 71

22 + 25 + 50 + 50

22 + 25 + 50 + 60

22 + 25 + 50 + 71

22 + 35 + 35 + 35

22 + 35 + 35 + 50

22 + 35 + 35 + 60

22 + 35 + 35 + 71

22 + 35 + 50 + 50

25 + 25 + 25 + 25

25 + 25 + 25 + 35

25 + 25 + 25 + 50

25 + 25 + 25 + 60

25 + 25 + 25 + 71

25 + 25 + 35 + 35

25 + 25 + 35 + 50

25 + 25 + 35 + 60

25 + 25 + 35 + 71

25 + 25 + 50 + 50

25 + 25 + 50 + 60

25 + 25 + 50 + 71

25 + 35 + 35 + 35

25 + 35 + 35 + 50

25 + 35 + 35 + 60

25 + 35 + 35 + 71

35 + 35 + 35 + 35

35 + 35 + 35 + 50

35 + 35 + 35 + 60

Unit A

1.32 / 1.61

1.37 / 1.68

1.29 / 1.57

1.24 / 1.47

1.78 / 2.26

1.63 / 2.05

1.50 / 1.98

1.42 / 1.83

1.38 / 1.69

1.57 / 2.07

1.42 / 1.83

1.40 / 1.70

1.29 / 1.58

1.35 / 1.65

1.26 / 1.54

1.22 / 1.44

1.48 / 1.91

1.39 / 1.70

1.30 / 1.59

1.25 / 1.48

1.31 / 1.54

1.98 / 2.50

1.82 / 2.27

1.70 / 2.20

1.59 / 2.04

1.54 / 1.88

1.73 / 2.29

1.67 / 2.04

1.55 / 1.90

1.47 / 1.76

1.50 / 1.83

1.45 / 1.72

1.39 / 1.61

1.63 / 2.12

1.55 / 1.89

1.48 / 1.77

1.40 / 1.66

2.25 / 2.75

2.08 / 2.48

1.97 / 2.33

Unit B

1.32 / 1.61

1.37 / 1.68

1.29 / 1.57

1.24 / 1.47

2.04 / 2.58

1.86 / 2.34

1.70 / 2.25

1.61 / 2.08

1.57 / 1.92

1.77 / 2.35

1.61 / 2.08

1.58 / 1.94

1.47 / 1.80

1.53 / 1.87

1.43 / 1.75

1.38 / 1.64

2.34 / 3.03

2.22 / 2.71

2.07 / 2.53

2.00 / 2.36

2.07 / 2.45

1.98 / 2.50

1.82 / 2.27

1.70 / 2.20

1.59 / 2.04

1.54 / 1.88

1.73 / 2.29

1.67 / 2.04

1.55 / 1.90

1.47 / 1.76

1.50 / 1.83

1.45 / 1.72

1.39 / 1.61

2.29 / 2.96

2.17 / 2.66

2.08 / 2.48

1.96 / 2.32

2.25 / 2.75

2.08 / 2.48

1.97 / 2.33

Unit C

2.10 / 2.57

3.13 / 3.82

2.92 / 3.57

2.82 / 3.33

2.04 / 2.58

1.86 / 2.34

1.70 / 2.25

1.61 / 2.08

1.57 / 1.92

2.48 / 3.29

2.25 / 2.92

2.22 / 2.71

2.06 / 2.52

3.06 / 3.74

2.87 / 3.50

2.77 / 3.27

2.34 / 3.03

2.22 / 2.71

2.07 / 2.53

2.00 / 2.36

2.96 / 3.50

1.98 / 2.50

1.82 / 2.27

1.70 / 2.20

1.59 / 2.04

1.54 / 1.88

2.42 / 3.21

2.33 / 2.85

2.17 / 2.66

2.06 / 2.47

3.00 / 3.67

2.91 / 3.44

2.78 / 3.22

2.29 / 2.96

2.17 / 2.66

2.08 / 2.48

1.96 / 2.32

2.25 / 2.75

2.08 / 2.48

1.97 / 2.33

Unit D

4.26 / 5.21

3.13 / 3.82

3.50 / 4.29

4.00 / 4.73

2.04 / 2.58

2.60 / 3.27

3.40 / 4.52

3.86 / 5.01

4.48 / 5.47

2.48 / 3.29

3.22 / 4.17

3.80 / 4.65

4.18 / 5.10

3.06 / 3.74

3.44 / 4.21

3.93 / 4.65

2.34 / 3.03

3.17 / 3.88

3.56 / 4.35

4.05 / 4.80

2.96 / 3.51

1.98 / 2.50

2.54 / 3.19

3.40 / 4.40

3.83 / 4.88

4.38 / 5.36

2.42 / 3.21

3.33 / 4.07

3.73 / 4.54

4.20 / 5.01

3.00 / 3.67

3.49 / 4.12

3.94 / 4.56

2.29 / 2.96

3.11 / 3.79

3.11 / 4.27

3.98 / 4.70

2.25 / 2.75

2.96 / 3.56

3.39 / 4.01

Indoor unitcombination

Cooling / Heating Capacity (kW)

25 + 25 + 25

25 + 25 + 35

25 + 25 + 50

25 + 25 + 60

25 + 25 + 71

25 + 35 + 35

25 + 35 + 50

25 + 35 + 60

25 + 35 + 71

25 + 50 + 50

25 + 50 + 60

25 + 50 + 71

25 + 60 + 60

25 + 60 + 71

35 + 35 + 35

35 + 35 + 50

35 + 35 + 60

35 + 35 + 71

35 + 50 + 50

35 + 50 + 60

35 + 50 + 71

35 + 60 + 60

35 + 60 + 71

50 + 50 + 50

50 + 50 + 60

50 + 50 + 71

4 ROOMS

22 + 22 + 22 + 22

22 + 22 + 22 + 25

22 + 22 + 22 + 35

22 + 22 + 22 + 50

22 + 22 + 22 + 60

22 + 22 + 22 + 71

22 + 22 + 25 + 25

22 + 22 + 25 + 35

22 + 22 + 25 + 50

22 + 22 + 25 + 60

22 + 22 + 25 + 71

22 + 22 + 35 + 35

22 + 22 + 35 + 50

22 + 22 + 35 + 60

Unit A

2.50 / 3.00

2.28 / 2.82

1.98 / 2.75

1.82 / 2.50

1.71 / 2.27

2.07 / 2.64

1.82 / 2.50

1.73 / 2.29

1.62 / 2.10

1.70 / 2.20

1.57 / 2.04

1.54 / 1.88

1.56 / 1.90

1.47 / 1.76

2.65 / 3.33

2.42 / 3.21

2.29 / 2.96

2.16 / 2.73

2.22 / 2.86

2.17 / 2.66

2.06 / 2.46

2.08 / 2.48

1.96 / 2.32

3.06 / 3.66

2.91 / 3.43

2.78 / 3.22

1.95 / 2.50

1.90 / 2.42

1.73 / 2.18

1.52 / 2.09

1.48 / 1.92

1.40 / 1.77

1.83 / 2.34

1.68 / 2.12

1.52 / 2.03

1.45 / 1.88

1.37 / 1.73

1.54 / 1.93

1.45 / 1.88

1.38 / 1.74

Unit B

2.50 / 3.00

2.28 / 2.82

1.98 / 2.75

1.82 / 2.50

1.71/ 2.27

2.89 / 3.68

2.54 / 3.50

2.42 / 3.21

2.27 / 2.94

3.40 / 4.40

3.15 / 4.07

3.08 / 3.77

3.72 / 4.55

3.54 / 4.23

2.65 / 3.33

2.42 / 3.21

2.29 / 2.96

2.16 / 2.73

3.19 / 4.07

3.10 / 3.79

2.95 / 3.53

3.56 / 4.26

3.36 / 3.98

3.07 / 3.67

2.91 / 3.44

2.78 / 3.22

1.95 / 2.50

1.90 / 2.42

1.73 / 2.18

1.52 / 2.09

1.48 / 1.92

1.40 / 1.77

1.84 / 2.34

1.68 / 2.12

1.52 / 2.03

1.45 / 1.88

1.37 / 1.73

1.54 / 1.93

1.45 / 1.88

1.38 / 1.74

Unit C

2.50 / 3.00

3.19 / 3.96

3.94 / 5.50

4.36 / 6.00

4.88 / 6.46

2.89 / 3.68

3.64 / 5.00

4.15 / 5.50

4.61 / 5.96

3.40 / 4.40

3.78 / 4.89

4.38 / 5.35

3.72 / 4.55

4.19 / 5.01

2.65 / 3.33

3.46 / 4.58

3.92 / 5.08

4.38 / 5.54

3.19 / 4.07

3.73 / 4.55

4.19 / 5.01

3.56 / 4.26

3.98 / 4.70

3.07 / 3.67

3.48 / 4.13

3.94 / 4.56

1.95 / 2.50

1.90 / 2.42

1.73 / 2.18

1.52 / 2.09

1.48 / 1.92

1.40 / 1.77

2.09 / 2.66

1.91 / 2.40

1.72 / 2.31

1.65 / 2.13

1.55 / 1.96

2.46 / 3.07

2.31 / 2.98

2.19 / 2.77

Unit D

1.95 / 2.50

2.15 / 2.74

2.76 / 3.46

3.44 / 4.73

4.06 / 5.24

4.50 / 5.69

2.09 / 2.66

2.68 / 3.36

3.44 / 4.63

3.95 / 5.11

4.41 / 5.58

2.46 / 3.07

3.29 / 4.26

3.75 / 4.75

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 43

Page 45: 2008 Product Catalogue

5 ROOMS22 + 22 + 22 + 22 + 22

22 + 22 + 22 + 22 + 25

22 + 22 + 22 + 22 + 35

22 + 22 + 22 + 22 + 50

22 + 22 + 22 + 22 + 60

22 + 22 + 22 + 22 + 71

22 + 22 + 22 + 25 + 25

22 + 22 + 22 + 25 + 35

22 + 22 + 22 + 25 + 50

22 + 22 + 22 + 25 + 60

22 + 22 + 22 + 25 + 71

22 + 22 + 22 + 35 + 35

22 + 22 + 22 + 35 + 50

22 + 22 + 22 + 35 + 60

22 + 22 + 22 + 35 + 71

22 + 22 + 25 + 25 + 25

22 + 22 + 25 + 25 + 35

22 + 22 + 25 + 25 + 50

22 + 22 + 25 + 25 + 60

22 + 22 + 25 + 25 + 71

22 + 22 + 25 + 35 + 35

22 + 22 + 25 + 35 + 50

22 + 22 + 35 + 35 + 35

22 + 25 + 25 + 25 + 25

22 + 25 + 25 + 25 + 35

22 + 25 + 25 + 25 + 50

22 + 25 + 25 + 25 + 60

22 + 25 + 25 + 25 + 71

22 + 25 + 25 + 35 + 35

22 + 25 + 25 + 35 + 50

22 + 25 + 25 + 35 + 60

22 + 25 + 35 + 35 + 35

25 + 25 + 25 + 25 + 25

25 + 25 + 25 + 25 + 35

25 + 25 + 25 + 25 + 50

25 + 25 + 25 + 25 + 60

25 + 25 + 25 + 25 + 71

25 + 25 + 25 + 35 + 35

25 + 25 + 35 + 35 + 35

25 + 25 + 35 + 35 + 50

Unit A

2.00 / 2.40

1.95 / 2.34

1.79 / 2.15

1.59 / 1.91

1.49 / 1.78

1.38 / 1.66

1.90 / 2.28

1.75 / 2.10

1.56 / 1.87

1.46 / 1.75

1.36 / 1.63

1.62 / 1.94

1.46 / 1.75

1.37 / 1.64

1.28 / 1.53

1.85 / 2.22

1.71 / 2.04

1.53 / 1.83

1.43 / 1.71

1.33 / 1.60

1.58 / 1.90

1.43 / 1.71

1.47 / 1.77

1.80 / 2.16

1.67 / 2.00

1.50 / 1.80

1.40 / 1.68

1.30 / 1.57

1.56 / 1.86

1.40 / 1.68

1.31 / 1.58

1.46 / 1.75

2.00 / 2.40

1.85 / 2.22

1.67 / 2.00

1.56 / 1.88

1.46 / 1.75

1.72 / 2.07

1.61 / 1.94

1.47 / 1.76

Unit B

2.00 / 2.40

1.95 / 2.34

1.79 / 2.15

1.59 / 1.91

1.49 / 1.78

1.38 / 1.66

1.90 / 2.28

1.75 / 2.10

1.56 / 1.87

1.46 / 1.75

1.36 / 1.63

1.62 / 1.94

1.46 / 1.75

1.37 / 1.64

1.28 / 1.53

1.85 / 2.22

1.71 / 2.04

1.53 / 1.83

1.43 / 1.71

1.33 / 1.60

1.58 / 1.90

1.43 / 1.71

1.48 / 1.77

2.05 / 2.46

1.89 / 2.27

1.70 / 2.04

1.59 / 1.91

1.49 / 1.79

1.76 / 2.11

1.59 / 1.91

1.50 / 1.80

1.64 / 1.97

2.00 / 2.40

1.85 / 2.22

1.67 / 2.00

1.56 / 1.88

1.46 / 1.75

1.72 / 2.07

1.61 / 1.94

1.47 / 1.76

Unit C

2.00 / 2.40

1.95 / 2.34

1.79 / 2.15

1.59 / 1.91

1.49 / 1.78

1.38 / 1.66

1.90 / 2.28

1.75 / 2.10

1.56 / 1.87

1.46 / 1.75

1.36 / 1.63

1.62 / 1.94

1.46 / 1.75

1.37 / 1.64

1.28 / 1.53

2.10 / 2.52

1.94 / 2.33

1.74 / 2.08

1.62 / 1.95

1.52 / 1.82

1.80 / 2.16

1.62 / 1.95

2.35 / 2.82

2.05 / 2.46

1.89 / 2.27

1.70 / 2.04

1.59 / 1.91

1.49 / 1.79

1.76 / 2.11

1.59 / 1.91

1.50 / 1.80

2.30 / 2.76

2.00 / 2.40

1.85 / 2.22

1.67 / 2.00

1.56 / 1.88

1.46 / 1.75

1.72 / 2.07

2.26 / 2.71

2.06 / 2.47

Unit D

2.00 / 2.40

1.95 / 2.34

1.79 / 2.15

1.59 / 1.91

1.49 / 1.78

1.38 / 1.66

2.15 / 2.58

1.97 / 2.38

1.77 / 2.13

1.66 / 1.99

1.54 / 1.85

2.57 / 3.09

2.32 / 2.78

2.17 / 2.61

2.03 / 2.44

2.10 / 2.52

1.94 / 2.33

1.74 / 2.08

1.62 / 1.95

1.52 / 1.82

2.52 / 3.02

2.27 / 2.73

2.35 / 2.82

2.05 / 2.46

1.89 / 2.27

1.70 / 2.04

1.59 / 1.91

1.49 / 1.79

2.46 / 2.96

2.23 / 2.68

2.10 / 2.51

2.30 / 2.76

2.00 / 2.40

1.85 / 2.22

1.67 / 2.00

1.56 / 1.88

1.46 / 1.75

2.42 / 2.90

2.26 / 2.71

2.06 / 2.47

Unit E

2.00 / 2.40

2.20 / 2.65

2.84 / 3.40

3.64 / 4.36

4.04 / 4.88

4.48 / 5.36

2.15 / 2.58

2.78 / 3.32

3.55 / 4.26

3.96 / 4.76

4.38 / 5.26

2.57 / 3.09

3.30 / 3.97

3.72 / 4.47

4.13 / 4.95

2.10 / 2.52

2.70 / 3.26

3.46 / 4.18

3.90 / 4.68

4.30 / 5.16

2.52 / 3.02

3.25 / 3.90

2.35 / 2.82

2.05 / 2.46

2.66 / 3.19

3.40 / 4.08

3.83 / 4.59

4.23 / 5.07

2.46 / 2.96

3.19 / 3.82

3.59 / 4.31

2.30 / 2.76

2.00 / 2.40

2.60 / 3.12

3.32 / 4.00

3.76 / 4.50

4.16 / 4.98

2.42 / 2.90

2.26 / 2.71

2.94 / 3.54

Unit F Unit G Unit H

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 44

Page 46: 2008 Product Catalogue

1 ROOM22

25

35

50

60

71

2 ROOMS22 + 22

22 + 25

22 + 35

22 + 50

22 + 60

22 + 71

25 + 25

25 + 35

25 + 50

25 + 60

25 + 71

35 + 35

35 + 50

35 + 60

35 + 71

50 + 50

50 + 60

50 + 71

60 + 60

60 + 71

71 + 71

3 ROOMS22 + 22 + 22

22 + 22 + 25

22 + 22 + 35

22 + 22 + 50

22 + 22 + 60

22 + 22 + 71

22 + 25 + 25

22 + 25 + 35

Unit A

2.20 / 3.30

2.50 / 3.60

3.50 / 4.00

5.00 / 7.20

6.00 / 7.90

7.10 / 8.60

2.20 / 2.50

2.20 / 2.53

2.20 / 2.51

2.20 / 2.51

2.20 / 2.52

2.20 / 2.51

2.50 / 2.85

2.50 / 2.88

2.50 / 2.87

2.50 / 2.85

2.50 / 2.86

3.50 / 4.00

3.50 / 3.99

3.50 / 4.02

3.50 / 4.00

5.00 / 5.70

5.00 / 5.73

5.00 / 5.70

6.00 / 6.85

6.00 / 6.87

7.00 / 8.00

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.20 / 2.50

2.20 / 2.52

Unit B

2.20 / 2.50

2.50 / 2.87

3.50 / 3.99

5.00 / 5.69

6.00 / 6.88

7.10 / 8.09

2.50 / 2.85

3.50 / 4.02

5.00 / 5.73

6.00 / 6.85

7.10 / 8.14

3.50 / 4.00

5.00 / 5.71

6.00 / 6.88

7.10 / 8.10

5.00 / 5.70

6.00 / 6.87

7.10 / 8.10

6.00 / 6.85

7.10 / 8.13

7.00 / 8.00

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.50 / 2.85

2.50 / 2.87

Unit C

2.20 / 2.50

2.50 / 2.86

3.50 / 3.98

5.00 / 5.69

6.00 / 6.86

7.10 / 8.09

2.50 / 2.85

3.50 / 4.01

Unit D

Indoor unitcombination

Cooling / Heating Capacity (kW)

MXZ-8A140VA1Outdoor Unit Up to 8 Indoor Units

22 + 25 + 50

22 + 25 + 60

22 + 25 + 71

22 + 35 + 35

22 + 35 + 50

22 + 35 + 60

22 + 35 + 71

22 + 50 + 50

22 + 50 + 60

22 + 50 + 71

22 + 60 + 60

22 + 60 + 71

22 + 71 + 71

25 + 25 + 25

25 + 25 + 35

25 + 25 + 50

25 + 25 + 60

25 + 25 + 71

25 + 35 + 35

25 + 35 + 50

25 + 35 + 60

25 + 35 + 71

25 + 50 + 50

25 + 50 + 60

25 + 50 + 71

25 + 60 + 60

25 + 60 + 71

25 + 71 + 71

35 + 35 + 35

35 + 35 + 50

35 + 35 + 60

35 + 35 + 71

35 + 50 + 50

35 + 50 + 60

35 + 50 + 71

35 + 60 + 60

35 + 60 + 71

35 + 71 + 71

50 + 50 + 50

50 + 50 + 60

50 + 50 + 71

50 + 60 + 60

50 + 60 + 71

60 + 60 + 60

Unit A

2.20 / 2.52

2.20 / 2.51

2.20 / 2.52

2.20 / 2.51

2.20 / 2.51

2.20 / 2.52

2.20 / 2.51

2.20 / 2.50

2.20 / 2.52

2.15 / 2.46

2.17 / 2.48

2.01 / 2.30

1.88 / 2.14

2.50 / 2.86

2.50 / 2.85

2.50 / 2.85

2.50 / 2.86

2.50 / 2.85

2.50 / 2.86

2.50 / 2.86

2.50 / 2.85

2.50 / 2.86

2.50 / 2.86

2.50 / 2.85

2.40 / 2.74

2.41 / 2.76

2.24 / 2.56

2.10 / 2.40

3.50 / 4.00

3.50 / 4.00

3.50 / 4.01

3.48 / 3.97

3.50 / 3.99

3.38 / 3.86

3.14 / 3.59

3.16 / 3.61

2.95 / 3.37

2.77 / 3.16

4.67 / 5.33

4.38 / 5.00

4.09 / 4.68

4.12 / 4.70

3.87 / 4.42

4.67 / 5.33

Unit B

2.50 / 2.86

2.50 / 2.85

2.50 / 2.86

3.50 / 3.99

3.50 / 3.99

3.50 / 4.01

3.50 / 3.99

5.00 / 5.70

5.00 / 5.72

4.90 / 5.59

5.92 / 6.76

5.49 / 6.27

6.06 / 6.93

2.50 / 2.86

2.50 / 2.85

2.50 / 2.85

2.50 / 2.86

2.50 / 2.85

3.50 / 4.02

3.50 / 4.01

3.50 / 4.00

3.50 / 4.01

5.00 / 5.72

5.00 / 5.70

4.79 / 5.48

5.79 / 6.62

5.38 / 6.15

5.95 / 6.80

3.50 / 4.00

3.50 / 4.00

3.50 / 4.01

3.48 / 3.97

5.00 / 5.70

4.83 / 5.52

4.49 / 5.13

5.42 / 6.19

5.06 / 5.78

5.62 / 6.42

4.67 / 5.33

4.38 / 5.00

4.09 / 4.68

4.94 / 5.65

4.64 / 5.30

4.67 / 5.33

Unit C

5.00 / 5.72

6.00 / 6.84

7.10 / 8.12

3.50 / 3.99

5.00 / 5.70

6.00 / 6.87

7.10 / 8.10

5.00 / 5.70

6.00 / 6.86

6.95 / 7.94

5.92 / 6.76

6.50 / 7.42

6.06 / 6.93

2.50 / 2.86

3.50 / 3.99

5.00 / 5.70

6.00 / 6.87

7.10 / 8.10

3.50 / 4.02

5.00 / 5.73

6.00 / 6.85

7.10 / 8.13

5.00 / 5.72

6.00 / 6.84

6.81 / 7.78

5.79 / 6.62

6.37 / 7.28

5.95 / 6.80

3.50 / 4.00

5.00 / 5.70

6.00 / 6.88

7.05 / 8.06

5.00 / 5.70

5.79 / 6.62

6.37 / 7.28

5.42 / 6.19

5.99 / 6.84

5.62 / 6.42

4.67 / 5.33

5.25 / 6.00

5.81 / 6.64

4.94 / 5.65

5.49 / 6.28

4.67 / 5.33

Unit D

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 45

Page 47: 2008 Product Catalogue

4 ROOMS22 + 22 + 22 + 22

22 + 22 + 22 + 25

22 + 22 + 22 + 35

22 + 22 + 22 + 50

22 + 22 + 22 + 60

22 + 22 + 22 + 71

22 + 22 + 25 + 25

22 + 22 + 25 + 35

22 + 22 + 25 + 50

22 + 22 + 25 + 60

22 + 22 + 25 + 71

22 + 22 + 35 + 35

22 + 22 + 35 + 50

22 + 22 + 35 + 60

22 + 22 + 35 + 71

22 + 22 + 50 + 50

22 + 22 + 50 + 60

22 + 22 + 50 + 71

22 + 22 + 60 + 60

22 + 22 + 60 + 71

22 + 25 + 25 + 25

22 + 25 + 25 + 35

22 + 25 + 25 + 50

22 + 25 + 25 + 60

22 + 25 + 25 + 71

22 + 25 + 35 + 35

22 + 25 + 35 + 50

22 + 25 + 35 + 60

22 + 25 + 35 + 71

22 + 25 + 50 + 50

22 + 25 + 50 + 60

22 + 25 + 50 + 71

22 + 25 + 60 + 60

22 + 25 + 60 + 71

22 + 35 + 35 + 35

22 + 35 + 35 + 50

Unit A

2.20 / 2.52

2.20 / 2.51

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.20 / 2.52

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.20 / 2.51

2.20 / 2.51

2.20 / 2.51

2.20 / 2.51

2.20 / 2.52

2.05 / 2.35

2.14 / 2.44

2.00 / 2.29

1.87 / 2.13

1.88 / 2.15

1.76 / 2.01

2.20 / 2.52

2.20 / 2.51

2.20 / 2.51

2.20 / 2.52

2.15 / 2.46

2.20 / 2.52

2.20 / 2.52

2.17 / 2.48

2.01 / 2.30

2.10 / 2.39

1.96 / 2.24

1.83 / 2.10

1.84 / 2.10

1.73 / 1.98

2.20 / 2.50

2.17 / 2.48

Unit B

2.20 / 2.52

2.20 / 2.51

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.20 / 2.52

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.20 / 2.51

2.20 / 2.51

2.20 / 2.51

2.20 / 2.51

2.20 / 2.52

2.05 / 2.35

2.14 / 2.44

2.00 / 2.29

1.87 / 2.13

1.88 / 2.15

1.76 / 2.01

2.50 / 2.86

2.50 / 2.85

2.50 / 2.85

2.50 / 2.86

2.45 / 2.80

2.50 / 2.86

2.50 / 2.86

2.46 / 2.82

2.29 / 2.61

2.38 / 2.72

2.23 / 2.55

2.08 / 2.38

2.10 / 2.40

1.97 / 2.25

3.50 / 4.00

3.45 / 3.94

Unit C

2.20 / 2.52

2.20 / 2.51

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.20 / 2.52

2.50 / 2.85

2.50 / 2.86

2.50 / 2.86

2.50 / 2.85

2.50 / 2.86

3.50 / 3.99

3.50 / 3.99

3.50 / 4.00

3.27 / 3.73

4.86 / 5.56

4.55 / 5.19

4.24 / 4.85

5.12 / 5.85

4.80 / 5.49

2.50 / 2.86

2.50 / 2.85

2.50 / 2.85

2.50 / 2.86

2.45 / 2.80

3.50 / 4.01

3.50 / 4.00

3.45 / 3.94

3.20 / 3.66

4.76 / 5.44

4.46 / 5.10

4.17 / 4.76

5.03 / 5.75

4.72 / 5.39

3.50 / 4.00

3.45 / 3.94

Unit D

2.20 / 2.52

2.50 / 2.86

3.50 / 3.99

5.00 / 5.73

6.00 / 6.86

7.10 / 8.14

2.50 / 2.85

3.50 / 4.00

5.00 / 5.71

6.00 / 6.83

7.10 / 8.11

3.50 / 3.99

5.00 / 5.69

6.00 / 6.86

6.63 / 7.57

4.86 / 5.56

5.45 / 6.23

6.02 / 6.88

5.12 / 5.85

5.68 / 6.49

2.50 / 2.86

3.50 / 3.99

5.00 / 5.69

6.00 / 6.86

6.95 / 7.94

3.50 / 4.01

5.00 / 5.72

5.92 / 6.76

6.50 / 7.42

4.76 / 5.44

5.35 / 6.11

5.92 / 6.76

5.03 / 5.75

5.58 / 6.38

3.50 / 4.00

4.93 / 5.63

Indoor unitcombination

Cooling / Heating Capacity (kW)

22 + 35 + 35 + 60

22 + 35 + 35 + 71

22 + 35 + 50 + 50

22 + 35 + 50 + 60

22 + 35 + 50 + 71

22 + 35 + 60 + 60

22 + 50 + 50 + 50

22 + 50 + 50 + 60

25 + 25 + 25 + 25

25 + 25 + 25 + 35

25 + 25 + 25 + 50

25 + 25 + 25 + 60

25 + 25 + 25 + 71

25 + 25 + 35 + 35

25 + 25 + 35 + 50

25 + 25 + 35 + 60

25 + 25 + 35 + 71

25 + 25 + 50 + 50

25 + 25 + 50 + 60

25 + 25 + 50 + 71

25 + 25 + 60 + 60

25 + 25 + 60 + 71

25 + 35 + 35 + 35

25 + 35 + 35 + 50

25 + 35 + 35 + 60

25 + 35 + 35 + 71

25 + 35 + 50 + 50

25 + 35 + 50 + 60

25 + 35 + 50 + 71

25 + 35 + 60 + 60

25 + 50 + 50 + 50

25 + 50 + 50 + 60

35 + 35 + 35 + 35

35 + 35 + 35 + 50

35 + 35 + 35 + 60

35 + 35 + 35 + 71

35 + 35 + 50 + 50

35 + 35 + 50 + 60

35 + 50 + 50 + 50

Unit A

2.03 / 2.32

1.89 / 2.16

1.96 / 2.23

1.84 / 2.11

1.73 / 1.98

1.73 / 1.99

1.79 / 2.05

1.69 / 1.93

2.50 / 2.85

2.50 / 2.86

2.50 / 2.86

2.50 / 2.85

2.40 / 2.74

2.50 / 2.85

2.50 / 2.85

2.41 / 2.76

2.24 / 2.56

2.33 / 2.67

2.19 / 2.50

2.05 / 2.34

2.06 / 2.35

1.93 / 2.21

2.50 / 2.87

2.41 / 2.76

2.26 / 2.58

2.11 / 2.41

2.18 / 2.50

2.06 / 2.35

1.93 / 2.21

1.94 / 2.22

2.00 / 2.29

1.89 / 2.16

3.50 / 4.00

3.16 / 3.61

2.97 / 3.39

2.78 / 3.18

2.88 / 3.29

2.72 / 3.11

2.65 / 3.03

Unit B

3.22 / 3.68

3.01 / 3.44

3.12 / 3.57

2.93 / 3.35

2.75 / 3.15

2.77 / 3.16

4.07 / 4.65

3.85 / 4.40

2.50 / 2.85

2.50 / 2.86

2.50 / 2.86

2.50 / 2.85

2.40 / 2.74

2.50 / 2.85

2.50 / 2.85

2.41 / 2.76

2.24 / 2.56

2.33 / 2.67

2.19 / 2.50

2.05 / 2.34

2.06 / 2.35

1.93 / 2.21

3.50 / 4.01

3.38 / 3.86

3.16 / 3.61

2.95 / 3.37

3.06 / 3.50

2.88 / 3.29

2.71 / 3.09

2.72 / 3.11

4.00 / 4.57

3.78 / 4.32

3.50 / 4.00

3.16 / 3.61

2.97 / 3.39

2.78 / 3.18

2.88 / 3.29

2.72 / 3.11

3.78 / 4.32

Unit C

3.22 / 3.68

3.01 / 3.44

4.46 / 5.10

4.19 / 4.79

3.93 / 4.49

4.75 / 5.42

4.07 / 4.65

3.85 / 4.40

2.50 / 2.85

2.50 / 2.86

2.50 / 2.86

2.50 / 2.85

2.40 / 2.74

3.50 / 4.00

3.50 / 3.99

3.38 / 3.86

3.14 / 3.59

4.67 / 5.33

4.38 / 5.00

4.09 / 4.68

4.94 / 5.65

4.64 / 5.30

3.50 / 4.01

3.38 / 3.86

3.16 / 3.61

2.95 / 3.37

4.38 / 5.00

4.12 / 4.71

3.87 / 4.42

4.67 / 5.33

4.00 / 4.57

3.78 / 4.32

3.50 / 4.00

3.16 / 3.61

2.97 / 3.39

2.78 / 3.18

4.12 / 4.71

3.89 / 4.44

3.78 / 4.32

Unit D

5.53 / 6.32

6.09 / 6.96

4.46 / 5.10

5.03 / 5.75

5.58 / 6.38

4.75 / 5.42

4.07 / 4.65

4.61 / 5.27

2.50 / 2.85

3.50 / 4.01

5.00 / 5.72

6.00 / 6.84

6.80 / 7.78

3.50 / 4.00

5.00 / 5.70

5.79 / 6.62

6.37 / 7.28

4.67 / 5.33

5.24 / 6.00

5.81 / 6.64

4.94 / 5.65

5.49 / 6.28

3.50 / 4.01

4.83 / 5.52

5.42 / 6.19

5.99 / 6.84

4.38 / 5.00

4.94 / 5.65

5.49 / 6.28

4.67 / 5.33

4.00 / 4.57

4.54 / 5.19

3.50 / 4.00

4.52 / 5.16

5.09 / 5.82

5.65 / 6.45

4.12 / 4.71

4.67 / 5.33

3.78 / 4.32

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 46

Page 48: 2008 Product Catalogue

5 ROOMS22 + 22 + 22 + 22 + 22

22 + 22 + 22 + 22 + 25

22 + 22 + 22 + 22 + 35

22 + 22 + 22 + 22 + 50

22 + 22 + 22 + 22 + 60

22 + 22 + 22 + 22 + 71

22 + 22 + 22 + 25 + 25

22 + 22 + 22 + 25 + 35

22 + 22 + 22 + 25 + 50

22 + 22 + 22 + 25 + 60

22 + 22 + 22 + 25 + 71

22 + 22 + 22 + 35 + 35

22 + 22 + 22 + 35 + 50

22 + 22 + 22 + 35 + 60

22 + 22 + 22 + 35 + 71

22 + 22 + 22 + 50 + 50

22 + 22 + 22 + 50 + 60

22 + 22 + 25 + 25 + 25

22 + 22 + 25 + 25 + 35

22 + 22 + 25 + 25 + 50

22 + 22 + 25 + 25 + 60

22 + 22 + 25 + 25 + 71

22 + 22 + 25 + 35 + 35

22 + 22 + 25 + 35 + 50

22 + 22 + 25 + 35 + 60

22 + 22 + 25 + 35 + 71

22 + 22 + 25 + 50 + 50

22 + 22 + 25 + 50 + 60

22 + 22 + 35 + 35 + 35

22 + 22 + 35 + 35 + 50

22 + 22 + 35 + 35 + 60

22 + 22 + 35 + 35 + 71

22 + 22 + 35 + 50 + 50

22 + 25 + 25 + 25 + 25

22 + 25 + 25 + 25 + 35

22 + 25 + 25 + 25 + 50

22 + 25 + 25 + 25 + 60

22 + 25 + 25 + 25 + 71

22 + 25 + 25 + 35 + 35

22 + 25 + 25 + 35 + 50

22 + 25 + 25 + 35 + 60

22 + 25 + 25 + 35 + 71

22 + 25 + 25 + 50 + 50

22 + 25 + 25 + 50 + 60

22 + 25 + 35 + 35 + 35

22 + 25 + 35 + 35 + 50

22 + 25 + 35 + 35 + 60

22 + 25 + 35 + 50 + 50

22 + 35 + 35 + 35 + 35

22 + 35 + 35 + 35 + 50

Unit A

2.20 / 2.52

2.20 / 2.51

2.20 / 2.52

2.20 / 2.52

2.08 / 2.38

1.94 / 2.21

2.20 / 2.52

2.20 / 2.51

2.18 / 2.50

2.04 / 2.33

1.90 / 2.17

2.20 / 2.51

2.04 / 2.33

1.91 / 2.19

1.79 / 2.05

1.86 / 2.12

1.75 / 2.00

2.20 / 2.51

2.20 / 2.51

2.14 / 2.44

2.00 / 2.29

1.87 / 2.13

2.20 / 2.52

2.00 / 2.29

1.88 / 2.15

1.76 / 2.01

1.82 / 2.08

1.72 / 1.97

2.06 / 2.36

1.88 / 2.15

1.77 / 2.02

1.66 / 1.90

1.72 / 1.97

2.20 / 2.50

2.20 / 2.52

2.10 / 2.39

1.96 / 2.24

1.83 / 2.10

2.17 / 2.48

1.96 / 2.24

1.84 / 2.11

1.73 / 1.98

1.79 / 2.04

1.69 / 1.93

2.03 / 2.32

1.84 / 2.11

1.74 / 1.99

1.69 / 1.92

1.90 / 2.16

1.74 / 1.99

Unit B

2.20 / 2.52

2.20 / 2.51

2.20 / 2.52

2.20 / 2.52

2.08 / 2.38

1.94 / 2.21

2.20 / 2.52

2.20 / 2.51

2.18 / 2.50

2.04 / 2.33

1.90 / 2.17

2.20 / 2.51

2.04 / 2.33

1.91 / 2.19

1.79 / 2.05

1.86 / 2.12

1.75 / 2.00

2.20 / 2.51

2.20 / 2.51

2.14 / 2.44

2.00 / 2.29

1.87 / 2.13

2.20 / 2.52

2.00 / 2.29

1.88 / 2.15

1.76 / 2.01

1.82 / 2.08

1.72 / 1.97

2.06 / 2.36

1.88 / 2.15

1.77 / 2.02

1.66 / 1.90

1.72 / 1.97

2.50 / 2.85

2.50 / 2.86

2.38 / 2.72

2.23 / 2.55

2.08 / 2.38

2.46 / 2.82

2.23 / 2.55

2.10 / 2.40

1.97 / 2.25

2.03 / 2.33

1.92 / 2.20

2.30 / 2.63

2.10 / 2.40

1.98 / 2.26

1.92 / 2.20

3.02 / 3.46

2.77 / 3.16

Unit C

2.20 / 2.52

2.20 / 2.51

2.20 / 2.52

2.20 / 2.52

2.08 / 2.38

1.94 / 2.21

2.20 / 2.52

2.20 / 2.51

2.18 / 2.50

2.04 / 2.33

1.90 / 2.17

2.20 / 2.51

2.04 / 2.33

1.91 / 2.19

1.79 / 2.05

1.86 / 2.12

1.75 / 2.00

2.50 / 2.86

2.50 / 2.85

2.43 / 2.78

2.27 / 2.60

2.12 / 2.42

2.50 / 2.86

2.27 / 2.60

2.13 / 2.44

2.00 / 2.29

2.07 / 2.37

1.96 / 2.23

3.29 / 3.76

2.99 / 3.41

2.82 / 3.22

2.65 / 3.03

2.74 / 3.12

2.50 / 2.85

2.50 / 2.86

2.38 / 2.72

2.23 / 2.55

2.08 / 2.38

2.46 / 2.82

2.23 / 2.55

2.10 / 2.40

1.97 / 2.25

2.03 / 2.33

1.92 / 2.20

3.22 / 3.68

2.93 / 3.35

2.77 / 3.16

2.69 / 3.08

3.02 / 3.46

2.77 / 3.16

Unit D

2.20 / 2.52

2.20 / 2.51

2.20 / 2.52

2.20 / 2.52

2.08 / 2.38

1.94 / 2.21

2.50 / 2.87

2.50 / 2.86

2.48 / 2.84

2.32 / 2.65

2.16 / 2.47

3.50 / 3.98

3.25 / 3.71

3.04 / 3.48

2.85 / 3.26

4.21 / 4.82

3.98 / 4.55

2.50 / 2.86

2.50 / 2.85

2.43 / 2.78

2.27 / 2.60

2.12 / 2.42

3.50 / 4.00

3.18 / 3.64

2.99 / 3.41

2.80 / 3.20

4.14 / 4.73

3.91 / 4.47

3.29 / 3.76

2.99 / 3.41

2.82 / 3.22

2.65 / 3.03

3.91 / 4.47

2.50 / 2.85

2.50 / 2.86

2.38 / 2.72

2.23 / 2.55

2.08 / 2.38

3.45 / 3.94

3.12 / 3.57

2.93 / 3.35

2.75 / 3.15

4.07 / 4.65

3.85 / 4.40

3.22 / 3.68

2.93 / 3.35

2.77 / 3.16

3.85 / 4.40

3.02 / 3.46

2.77 / 3.16

Unit E

2.20 / 2.52

2.50 / 2.85

3.50 / 4.01

5.00 / 5.72

5.68 / 6.48

6.24 / 7.14

2.50 / 2.87

3.50 / 4.00

4.96 / 5.66

5.56 / 6.36

6.14 / 7.01

3.50 / 3.98

4.63 / 5.30

5.22 / 5.95

5.78 / 6.59

4.21 / 4.82

4.77 / 5.45

2.50 / 2.86

3.50 / 3.98

4.86 / 5.56

5.45 / 6.22

6.02 / 6.88

3.50 / 4.00

4.55 / 5.18

5.12 / 5.85

5.68 / 6.49

4.14 / 4.73

4.69 / 5.36

3.29 / 3.76

4.26 / 4.88

4.82 / 5.52

5.37 / 6.14

3.91 / 4.47

2.50 / 2.85

3.50 / 4.00

4.76 / 5.44

5.35 / 6.11

5.92 / 6.76

3.45 / 3.94

4.46 / 5.09

5.03 / 5.74

5.58 / 6.37

4.07 / 4.65

4.62 / 5.27

3.22 / 3.68

4.19 / 4.79

4.74 / 5.42

3.85 / 4.40

3.02 / 3.46

3.95 / 4.52

Unit F Unit G Unit H

Indoor unitcombination Cooling / Heating Capacity (kW)

Page 47

Page 49: 2008 Product Catalogue

25 + 25 + 25 + 25 + 25

25 + 25 + 25 + 25 + 35

25 + 25 + 25 + 25 + 50

25 + 25 + 25 + 25 + 60

25 + 25 + 25 + 25 + 71

25 + 25 + 25 + 35 + 35

25 + 25 + 25 + 35 + 50

25 + 25 + 25 + 35 + 60

25 + 25 + 25 + 35 + 71

25 + 25 + 25 + 50 + 50

25 + 25 + 25 + 50 + 60

25 + 25 + 35 + 35 + 35

25 + 25 + 35 + 35 + 50

25 + 25 + 35 + 35 + 60

25 + 25 + 35 + 50 + 50

25 + 35 + 35 + 35 + 35

25 + 35 + 35 + 35 + 50

35 + 35 + 35 + 35 + 35

6 ROOMS22 + 22 + 22 + 22 + 22 + 22

22 + 22 + 22 + 22 + 22 + 25

22 + 22 + 22 + 22 + 22 + 35

22 + 22 + 22 + 22 + 22 + 50

22 + 22 + 22 + 22 + 22 + 60

22 + 22 + 22 + 22 + 22 + 71

22 + 22 + 22 + 22 + 25 + 25

22 + 22 + 22 + 22 + 25 + 35

22 + 22 + 22 + 22 + 25 + 50

22 + 22 + 22 + 22 + 25 + 60

22 + 22 + 22 + 22 + 25 + 71

22 + 22 + 22 + 22 + 35 + 35

22 + 22 + 22 + 22 + 35 + 50

22 + 22 + 22 + 22 + 35 + 60

22 + 22 + 22 + 25 + 25 + 25

22 + 22 + 22 + 25 + 25 + 35

22 + 22 + 22 + 25 + 25 + 50

22 + 22 + 22 + 25 + 25 + 60

22 + 22 + 22 + 25 + 35 + 35

22 + 22 + 22 + 25 + 35 + 50

22 + 22 + 22 + 35 + 35 + 35

22 + 22 + 25 + 25 + 25 + 25

22 + 22 + 25 + 25 + 25 + 35

22 + 22 + 25 + 25 + 25 + 50

22 + 22 + 25 + 25 + 25 + 60

22 + 22 + 25 + 25 + 35 + 35

22 + 22 + 25 + 25 + 35 + 50

22 + 22 + 25 + 35 + 35 + 35

22 + 22 + 35 + 35 + 35 + 35

22 + 25 + 25 + 25 + 25 + 25

Unit A

2.50 / 2.86

2.50 / 2.85

2.33 / 2.67

2.19 / 2.50

2.05 / 2.34

2.41 / 2.76

2.19 / 2.50

2.06 / 2.35

1.93 / 2.21

2.00 / 2.29

1.89 / 2.16

2.26 / 2.58

2.06 / 2.35

1.94 / 2.22

1.89 / 2.16

2.12 / 2.42

1.94 / 2.22

2.80 / 3.20

2.20 / 2.51

2.20 / 2.51

2.12 / 2.43

1.92 / 2.20

1.81 / 2.07

1.70 / 1.94

2.20 / 2.52

2.08 / 2.38

1.89 / 2.16

1.78 / 2.03

1.67 / 1.91

1.95 / 2.23

1.78 / 2.03

1.68 / 1.92

2.18 / 2.50

2.04 / 2.33

1.86 / 2.12

1.75 / 2.00

1.91 / 2.19

1.75 / 2.00

1.80 / 2.06

2.14 / 2.44

2.00 / 2.28

1.82 / 2.08

1.72 / 1.97

1.88 / 2.15

1.72 / 1.97

1.70 / 2.02

1.67 / 1.91

2.10 / 2.39

Unit B

2.50 / 2.86

2.50 / 2.85

2.33 / 2.67

2.19 / 2.50

2.05 / 2.34

2.41 / 2.76

2.19 / 2.50

2.06 / 2.35

1.93 / 2.21

2.00 / 2.29

1.89 / 2.16

2.26 / 2.58

2.06 / 2.35

1.94 / 2.22

1.89 / 2.16

2.97 / 3.39

2.72 / 3.11

2.80 / 3.20

2.20 / 2.51

2.20 / 2.51

2.12 / 2.43

1.92 / 2.20

1.81 / 2.07

1.70 / 1.94

2.20 / 2.52

2.08 / 2.38

1.89 / 2.16

1.78 / 2.03

1.67 / 1.91

1.95 / 2.23

1.78 / 2.03

1.68 / 1.92

2.18 / 2.50

2.04 / 2.33

1.86 / 2.12

1.75 / 2.00

1.91 / 2.19

1.75 / 2.00

1.80 / 2.06

2.14 / 2.44

2.00 / 2.28

1.82 / 2.08

1.72 / 1.97

1.88 / 2.15

1.72 / 1.97

1.70 / 2.02

1.67 / 1.91

2.38 / 2.72

Unit C

2.50 / 2.86

2.50 / 2.85

2.33 / 2.67

2.19 / 2.50

2.05 / 2.34

2.41 / 2.76

2.19 / 2.50

2.06 / 2.35

1.93 / 2.21

2.00 / 2.29

1.89 / 2.16

3.16 / 3.61

2.88 / 3.29

2.72 / 3.11

2.65 / 3.03

2.97 / 3.39

2.72 / 3.11

2.80 / 3.20

2.20 / 2.51

2.20 / 2.51

2.12 / 2.43

1.92 / 2.20

1.81 / 2.07

1.70 / 1.94

2.20 / 2.52

2.08 / 2.38

1.89 / 2.16

1.78 / 2.03

1.67 / 1.91

1.95 / 2.23

1.78 / 2.03

1.68 / 1.92

2.18 / 2.50

2.04 / 2.33

1.86 / 2.12

1.75 / 2.00

1.91 / 2.19

1.75 / 2.00

1.80 / 2.06

2.43 / 2.78

2.27 / 2.60

2.07 / 2.37

1.96 / 2.23

2.13 / 2.44

1.96 / 2.23

2.00 / 2.30

2.66 / 3.04

2.38 / 2.72

Unit D

2.50 / 2.86

2.50 / 2.85

2.33 / 2.67

2.19 / 2.50

2.05 / 2.34

3.38 / 3.86

3.06 / 3.50

2.88 / 3.29

2.71 / 3.09

4.00 / 4.56

3.78 / 4.32

3.16 / 3.61

2.88 / 3.29

2.72 / 3.11

3.78 / 4.32

2.97 / 3.39

2.72 / 3.11

2.80 / 3.20

2.20 / 2.51

2.20 / 2.51

2.12 / 2.43

1.92 / 2.20

1.81 / 2.07

1.70 / 1.94

2.20 / 2.52

2.08 / 2.38

1.89 / 2.16

1.78 / 2.03

1.67 / 1.91

1.95 / 2.23

1.78 / 2.03

1.68 / 1.92

2.48 / 2.83

2.32 / 2.65

2.10 / 2.41

1.99 / 2.27

2.17 / 2.47

1.99 / 2.27

2.86 / 3.27

2.43 / 2.78

2.27 / 2.60

2.07 / 2.37

1.96 / 2.23

2.13 / 2.44

1.96 / 2.23

2.82 / 3.22

2.66 / 3.04

2.38 / 2.72

Unit E

2.50 / 2.86

3.50 / 3.99

4.67 / 5.32

5.24 / 6.00

5.80 / 6.64

3.38 / 3.86

4.37 / 5.00

4.94 / 5.65

5.49 / 6.28

4.00 / 4.56

4.54 / 5.19

3.16 / 3.61

4.12 / 4.71

4.67 / 5.33

3.78 / 4.32

2.97 / 3.39

3.89 / 4.44

2.80 / 3.20

2.20 / 2.51

2.20 / 2.51

2.12 / 2.43

1.92 / 2.20

1.81 / 2.07

1.70 / 1.94

2.50 / 2.86

2.36 / 2.70

2.15 / 2.45

2.02 / 2.31

1.90 / 2.17

3.10 / 3.54

2.83 / 3.24

2.68 / 3.06

2.48 / 2.83

2.32 / 2.65

2.10 / 2.41

1.99 / 2.27

3.04 / 3.48

2.78 / 3.18

2.86 / 3.27

2.43 / 2.78

2.27 / 2.60

2.07 / 2.37

1.96 / 2.23

2.99 / 3.41

2.74 / 3.13

2.82 / 3.22

2.66 / 3.04

2.38 / 2.72

Unit F

2.20 / 2.51

2.50 / 2.85

3.38 / 3.85

4.38 / 5.00

4.94 / 5.65

5.49 / 6.28

2.50 / 2.86

3.31 / 3.78

4.29 / 4.91

4.86 / 5.55

5.40 / 6.17

3.10 / 3.54

4.05 / 4.62

4.59 / 5.25

2.48 / 2.83

3.24 / 3.71

4.22 / 4.82

4.77 / 5.45

3.04 / 3.48

3.98 / 4.55

2.86 / 3.27

2.43 / 2.78

3.18 / 3.64

4.14 / 4.73

4.68 / 5.36

2.99 / 3.41

3.90 / 4.47

2.82 / 3.22

2.66 / 3.04

2.38 / 2.72

Unit G Unit H

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 48

Page 50: 2008 Product Catalogue

22 + 25 + 25 + 25 + 25 + 35

22 + 25 + 25 + 25 + 25 + 50

22 + 25 + 25 + 25 + 25 + 60

22 + 25 + 25 + 25 + 35 + 35

22 + 25 + 25 + 25 + 35 + 50

22 + 25 + 25 + 35 + 35 + 35

25 + 25 + 25 + 25 + 25 + 25

25 + 25 + 25 + 25 + 25 + 35

25 + 25 + 25 + 25 + 25 + 50

25 + 25 + 25 + 25 + 25 + 60

25 + 25 + 25 + 25 + 35 + 35

25 + 25 + 25 + 25 + 35 + 50

25 + 25 + 25 + 35 + 35 + 35

7 ROOMS22 + 22 + 22 + 22 + 22 + 22 + 22

22 + 22 + 22 + 22 + 22 + 22 + 25

22 + 22 + 22 + 22 + 22 + 22 + 35

22 + 22 + 22 + 22 + 22 + 22 + 50

22 + 22 + 22 + 22 + 22 + 25 + 25

22 + 22 + 22 + 22 + 22 + 25 + 35

22 + 22 + 22 + 22 + 22 + 25 + 50

22 + 22 + 22 + 22 + 22 + 35 + 35

22 + 22 + 22 + 22 + 25 + 25 + 25

22 + 22 + 22 + 22 + 25 + 25 + 35

22 + 22 + 22 + 22 + 25 + 35 + 35

22 + 22 + 22 + 25 + 25 + 25 + 25

22 + 22 + 22 + 25 + 25 + 25 + 35

22 + 22 + 25 + 25 + 25 + 25 + 25

22 + 22 + 25 + 25 + 25 + 25 + 35

22 + 25 + 25 + 25 + 25 + 25 + 25

22 + 25 + 25 + 25 + 25 + 25 + 35

25 + 25 + 25 + 25 + 25 + 25 + 25

25 + 25 + 25 + 25 + 25 + 25 + 35

8 ROOMS22 + 22 + 22 + 22 + 22 + 22 + 22 + 22

22 + 22 + 22 + 22 + 22 + 22 + 22 + 25

22 + 22 + 22 + 22 + 22 + 22 + 25 + 25

22 + 22 + 22 + 22 + 22 + 25 + 25 + 25

Unit A

1.96 / 2.24

1.79 / 2.04

1.69 / 1.93

1.84 / 2.10

1.69 / 1.93

1.73 / 1.99

2.33 / 2.66

2.19 / 2.50

2.00 / 2.28

1.89 / 2.16

2.06 / 2.35

1.89 / 2.16

1.94 / 2.22

2.00 / 2.28

1.96 / 2.24

1.84 / 2.11

1.69 / 1.93

1.92 / 2.20

1.81 / 2.07

1.66 / 1.90

1.71 / 1.96

1.89 / 2.16

1.78 / 2.03

1.68 / 1.92

1.85 / 2.12

1.75 / 2.00

1.82 / 2.07

1.71 / 1.97

1.79 / 2.05

1.69 / 1.93

2.00 / 2.28

1.89 / 2.16

1.75 / 2.00

1.72 / 1.96

1.69 / 1.93

1.66 / 1.90

Unit B

2.23 / 2.55

2.03 / 2.33

1.92 / 2.20

2.10 / 2.40

1.92 / 2.20

1.98 / 2.26

2.33 / 2.66

2.19 / 2.50

2.00 / 2.28

1.89 / 2.16

2.06 / 2.35

1.89 / 2.16

1.94 / 2.22

2.00 / 2.28

1.96 / 2.24

1.84 / 2.11

1.69 / 1.93

1.92 / 2.20

1.81 / 2.07

1.66 / 1.90

1.71 / 1.96

1.89 / 2.16

1.78 / 2.03

1.68 / 1.92

1.85 / 2.12

1.75 / 2.00

1.82 / 2.07

1.71 / 1.97

2.03 / 2.32

1.92 / 2.20

2.00 / 2.28

1.89 / 2.16

1.75 / 2.00

1.72 / 1.96

1.69 / 1.93

1.66 / 1.90

Unit C

2.23 / 2.55

2.03 / 2.33

1.92 / 2.20

2.10 / 2.40

1.92 / 2.20

1.98 / 2.26

2.33 / 2.66

2.19 / 2.50

2.00 / 2.28

1.89 / 2.16

2.06 / 2.35

1.89 / 2.16

1.94 / 2.22

2.00 / 2.28

1.96 / 2.24

1.84 / 2.11

1.69 / 1.93

1.92 / 2.20

1.81 / 2.07

1.66 / 1.90

1.71 / 1.96

1.89 / 2.16

1.78 / 2.03

1.68 / 1.92

1.85 / 2.12

1.75 / 2.00

2.07 / 2.37

1.96 / 2.23

2.03 / 2.32

1.92 / 2.20

2.00 / 2.28

1.89 / 2.16

1.75 / 2.00

1.72 / 1.96

1.69 / 1.93

1.66 / 1.90

Unit D

2.23 / 2.55

2.03 / 2.33

1.92 / 2.20

2.10 / 2.40

1.92 / 2.20

2.77 / 3.16

2.33 / 2.66

2.19 / 2.50

2.00 / 2.28

1.89 / 2.16

2.06 / 2.35

1.89 / 2.16

2.72 / 3.11

2.00 / 2.28

1.96 / 2.24

1.84 / 2.11

1.69 / 1.93

1.92 / 2.20

1.81 / 2.07

1.66 / 1.90

1.71 / 1.96

1.89 / 2.16

1.78 / 2.03

1.68 / 1.92

2.11 / 2.41

1.99 / 2.27

2.07 / 2.37

1.96 / 2.23

2.03 / 2.32

1.92 / 2.20

2.00 / 2.28

1.89 / 2.16

1.75 / 2.00

1.72 / 1.96

1.69 / 1.93

1.66 / 1.90

Unit E

2.23 / 2.55

2.03 / 2.33

1.92 / 2.20

2.93 / 3.35

2.69 / 3.08

2.77 / 3.16

2.33 / 2.66

2.19 / 2.50

2.00 / 2.28

1.89 / 2.16

2.88 / 3.29

2.65 / 3.03

2.72 / 3.11

2.00 / 2.28

1.96 / 2.24

1.84 / 2.11

1.69 / 1.93

1.92 / 2.20

1.81 / 2.07

1.66 / 1.90

1.71 / 1.96

2.14 / 2.45

2.02 / 2.31

1.91 / 2.19

2.11 / 2.41

1.99 / 2.27

2.07 / 2.37

1.96 / 2.23

2.03 / 2.32

1.92 / 2.20

2.00 / 2.28

1.89 / 2.16

1.75 / 2.00

1.72 / 1.96

1.69 / 1.93

1.66 / 1.90

Unit F

3.12 / 3.56

4.07 / 4.64

4.62 / 5.27

2.93 / 3.35

3.85 / 4.39

2.77 / 3.16

2.33 / 2.66

3.05 / 3.50

4.00 / 4.57

4.54 / 5.19

2.88 / 3.29

3.78 / 4.32

2.72 / 3.11

2.00 / 2.28

1.96 / 2.24

1.84 / 2.11

1.69 / 1.93

2.19 / 2.50

2.06 / 2.35

1.89 / 2.16

2.72 / 3.10

2.14 / 2.45

2.02 / 2.31

2.68 / 3.06

2.11 / 2.41

1.99 / 2.27

2.07 / 2.37

1.96 / 2.23

2.03 / 2.32

1.92 / 2.20

2.00 / 2.28

1.89 / 2.16

1.75 / 2.00

1.72 / 1.96

1.69 / 1.93

1.89 / 2.16

Unit G

2.00 / 2.28

2.23 / 2.55

2.93 / 3.34

3.85 / 4.40

2.19 / 2.50

2.88 / 3.29

3.78 / 4.32

2.72 / 3.10

2.14 / 2.45

2.83 / 3.24

2.68 / 3.06

2.11 / 2.41

2.78 / 3.18

2.07 / 2.37

2.74 / 3.13

2.03 / 2.32

2.69 / 3.07

2.00 / 2.28

2.65 / 3.03

1.75 / 2.00

1.72 / 1.96

1.92 / 2.20

1.89 / 2.16

Unit H

1.75 / 2.00

1.96 / 2.23

1.92 / 2.20

1.89 / 2.16

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 49

Page 51: 2008 Product Catalogue

Outdoor Units

Side View >

MUZ-GC35VA / MUZ-FD25/35VAH / SUZ-KA25/35VA

MUZ-HC25/35VA(B) / MUZ-GC25VA

Upper View >

Front View >

Side View >

Upper View >

Front View >

Dimensions

Page 50

Page 52: 2008 Product Catalogue

M S

erie

sR

ange

200

8O

utdo

or U

nit

Dim

ensi

ons

MUH-GA60VB / MUZ-GB50VA / MUZ-GA60/71VA / SUZ-KA50VA

Side View >Front View >

Upper View >

MUH-GA50VB

Side View >Front View >

Upper View >

Dimensions

Page 51

Page 53: 2008 Product Catalogue

M S

erie

sR

ange

200

8A

cces

sori

es /

Opt

iona

l Ext

ras

Accessories / Optional ExtrasM Series

Air Cleaning Filter MAC-1700FT - for MSH-GA50/60VB (10 pack)

Catechin Filter MAC-3003CF - for MSZ-HC25/35VA(B) (10 pack)

Anti-Allergy Enzyme Filter MAC-408FT-E - for MSZ-GC22-35VA (10 pack)MAC-415FT-E - for MSZ-GB50VA (10 pack)MAC-2300FT - for MSZ-GA60-71VA (10 pack)

Wired Remote controller PAR-21MAA - for MSZ-GC22-35VA, MSZ-GB50VA, MSZ-GA60/71VA, MSZ-FD25/35VA & MFZ-KA25-50VAMAC-821SC-E - Centralised Simple ON/OFF Remote Controller for MXZ Multi-Splits

Interfaces MAC-399IF - for connection to M-NET system

MAC-397IF - for Contact Terminal, PAR-21MAA Wired Remote Controller and MAC-821SC-E Centralised ON/OFF Remote Controller

Air Outlet Guide PAC-SG59SG-E - for MXZ-8A140VA

Page 52

Page 54: 2008 Product Catalogue

Mr SlimPackaged Split-System Air Conditioning

Page 55: 2008 Product Catalogue

The Mr Slim rangeCompact and versatile, the

The 2008 Mr Slim range has been updated with new features, as well as the alreadyimpressive efficiency levels being improved. New to the range are the 19 & 22kW outdoormodels, available in both Power Inverter and Standard Inverter options. The smalleroutdoor models have also undergone improvements, in line with Mitsubishi Electricsforward looking approach.

New indoor units include the SEZ-KD ducted models and four new large capacity ductedmodels (PEA-RP-GA) available in up to 44kW cooling capacity. A new range of 4-wayblow cassettes (PLA-RP-BA2) are now available with improved COP's and EER's, furtherincreasing Mitsubsihi Electrics energy efficient portfolio. Finally a range of Heat Pump Air Curtains have been developed with Thermoscreens, for use with our Power Invertermodels, an ideal application for a retail establishment.

Mr Slim units are more than just physically compact and discreet. They’re also amongst the quietest operating units available, which means that apart from enjoying a comfortable,controllable environment, users hardly know Mr Slim is there at all.

Suitable to heat or cool a huge variety of applications, the Mr Slim range is oneof Britain’s best selling air conditioning split-systems. Combine the efficiency with the complete versatility that this range has to offer and the possibilities are virtually infinite.

Page 54

Page 56: 2008 Product Catalogue

options are endless

Easy to f it wherever you need

An installers favourite, the excellent design of the Mr Slim range ensures quick and simple installation with the minimum of disruption. With extensive pipe runs of up to 120m, this versatile range makes it easier to select a layout to install the unit.

Page 57: 2008 Product Catalogue

The issue of using existing R22/R407c pipe work has been resolvedusing Mitsubishi Electric’s unique ‘Replace Technology’, offering the opportunity to upgrade older, less efficient systems with the minimum of cost and installation disruption.

* 1 Based on the following operating conditions - Place-Office in Tokyo, Japan / Operating time-8am to 8pm, 6 days/week / Operating period-Cooling: April 16 - November 8Heating: December 14 - March 23 / Set temperature-Cooling: 27°C, Heating: 20˚C. Non-inverter model installed eight years ago is a PLH-3GKHB / PUH-3YKA. Power Inverter model is a PLA-RP71BA2 / PUHZ-RP71VHA3.

The Mr Slim Power Inverter range is now stronger than ever. The technological developments applied to this new range of equipmentoffer the end user some of the highest energy efficiency ratings available,alongside greater application flexibility.

This range is available in single and 3-phase options, the latter having runningcurrents that are more than half that of the single phase option, offering a clear benefit to business premises that already have 3-phase supply installed. All models have low starting currents of 5 amps.

Power Inverter

Improved COP / EER Ratings - COP and EER ratings have increased across the board with many models within our range now having energy labels of ‘A’ in both heating and cooling.

Reducing Power Consumption by 70% - The Mr Slim Power Inverter canreduce power consumption by up to 70% compared to a previously installed non-invertermodel*1, making the energy cost savings associated with this range truly remarkable. A highpower function also delivers increased capacity at times of high demand, allowing the roomtarget temperature to be reached as rapidly as possible from start up.

Page 56

New 19 & 22kW models now available -

The unit size of these models has now beensignificantly reduced as displayed here.

Page 58: 2008 Product Catalogue

Silent OperationOperation has been made near-silent (67% quieter than corresponding R22 outdoor unit*1) as a result of improvement in the design of the fan blades and the new grille shape. The Power Inverter is even quieter at night when outsidetemperatures drop, as it can be set to low-noise mode (cooling only) reducing operating noise by 3dBA (50% quieter thannormal day mode). A low-noise priority function is also available by connecting a separate commercially available timer orselector switch. When a signal is received from the timer or switch, the unit automatically runs in low-noise mode.

Duty Standby Operation3 new functions are available with Mr Slim systems*2:

*1 When comparing the Power Inverter (PUHZ-RP71VHA3) with R22 (PUH3-VKA) in cooling.*2 Not available when using SUZ outdoor units. Must be used in conjunction with a PAR-21MAA controller.

Page 57

Rotation2 outdoor units (master & sub) operate alternately,switching every 1, 3, 5, 7, 14, 28 days (selectable).

Back UpWhen master outdoor unit fails, sub unit begins operation.

Join InWhen master outdoor unit fails to reach settemperature, sub unit operates in conjunction (available in cooling mode only).

Rotate

Back Up

Join In

Page 59: 2008 Product Catalogue

Improved COP / EER Figures - COP / EER figures have been improvedwhen compared to the previous R407c range.

The Standard Inverter models provide an inverter solution at a lowercapital cost than the Power Inverter range. These outdoor models continueto offer high efficiency as standard, with some systems qualifying forEnhanced Capital Allowance. Models are available in 10, 12.5 & 14kW singlephase and now 19 & 22kW three phase.

Standard Inverter

2.61 2.69 3.01 3.41EER COP

D E B B

COPImprovedby 27%

R407c Fixed speed unitPUH-P100VGAA

Standard InverterPUHZ-P100VHA2

EER

COP

Low noise mode can be set at night time to reduce noise levels by approximately 50%.

The example here is using a PUHZ-P100VHA2.

1350

mm

943m

m

330mm 330mm

407mm

950mm 950mm

Power Inverter

121kg Standard Inverter

75kg

Compared to Power Inverter

Height reduced by 407mm

Weight reduced by 46kg

Day 50dBAOutdoor Temperature 35ºC

Night 47dBAOutdoor Temperature 25ºC

1/2 the audible sound(compared to

daytime)

3dBALess

Example:

Silent Outdoor Unit - Low Noise Mode

10.0kW model now has acompact single fan design andweighs less, when compared to its Power Inverter equivalent,making installation easier.

Page 58

Page 60: 2008 Product Catalogue

Inverter solutionsat a lower price

SUZ outdoor units are able to be connected to selected Mr Slim indoor units, creating a new range of low cost inverter driven systems.

Pump down switch

Pump down switch

Pushing a switch starts / stops refrigerant recovery operation automatically. This work will then be completed by closing a valve.

Smooth refrigerant recovery can be assured by pushing the pump down switch at unit movement / renewal.

Design with Environmental Consideration

Page 59

Page 61: 2008 Product Catalogue

The PLA-RP-BA(2) (PLFY-P-VBM-E for City Multi)

4-Way Blow Cassette, offers a range of new features, as well as a new design and pure white colour.

New 4-Way Blow Cassette

Wide AirflowThe new wide shape vane (capable of wide angle air supply) provides comfort at the corners of a room, regardless of cooling or heating operation.A reduction in the air speed by 20% (compared to the previous product)eliminates the uncomfortable draft sensation often experienced.

Reduced Draft Air DistributionReduced draft air distribution allows the vanes to supply airflow horizontally, thus preventing discomfort due to excessive cooling or from direct exposure of occupants to the air blow.

Independent Vane ControlIf the airflow direction needs to be changed as a result of an altered room layout or due to the mode selected (i.e. cooling or heating), the air direction of each vane can be set independently using the PAR-21MAA wired remote controller.

Automatic Airflow Adjustment ModeThe automatic airflow adjustment mode is provided in addition to the 4 normal airflow stages and allowsautomatic adjustment of the airflow in accordance with the difference between the set temperature and the room temperature.

For example: The automatic airflow adjustment modeallows quick cooling of a room using high mode, thenwhen the room temperature has stabilised, the low mode will be applied to maximise comfort.

Grille with Automatic Filter LoweringFunction (Optional)This grille can be operated by both the wired remote controller and theexclusive infra-red remote controller.It can be lowered in 8 steps down to 4m in accordance with the ceiling height, enabling you to easily clean the air filter. Regular cleaning of the filter is an important factor in saving energy.

� Previous product � New product

Reduced Draft Air

Distribution

HighLow Automatic airflowadjustmentMedium 2 Medium 1

PAR-21MAA Wired Remote Controller

Elevation Grille Remote Controller

(comes with the grille)

PAR-21MAA

Down blow

Horizontal blow

Adjustable Fixed

Automaticlowering

to4m

Page 60

Page 62: 2008 Product Catalogue

360°The "I-See Sensor" rotates to measure the floor temperature

“Sensible Temperature Control” to Prevent Excessive Cooling and Heating

The (optional corner panel) Provides EvenTemperature Distribution and Reduces Energy Consumption

By measuring the inlet temperature and floor temperature, a temperature felt by the human body (sensible temperature) will be calculated and maintained, suppressing excessive cooling and heating.

The “I-See Sensor” uses new temperature sensing technology developed by Mitsubishi Electric. In order to create a comfortable environment in shops and offices, it is essential to control the temperature near the floor where occupants and visitors gather. The “I-See Sensor” measures the infra-red rays generated from the surrounding wall and floor surfaces and converts these into temperature values. In addition, floor temperatures are also measured at distant spots, allowing optimum airflow to reach these areas.

� “I-See Sensor” operation: The “I-See Sensor”rotates slowly in intervals of 5 seconds, correctly measuring the temperature of the entire floor space.

5 seconds 5 seconds 5 seconds 5 seconds

In the past... only the inlet temperature near the ceiling was measured, tending to overlook the uneven temperature distribution near the floor.

Conventional air conditioning in shops and offices onlymeasured the temperature near to the ceiling, therefore the uneven temperature distribution between the ceiling and the floor remained unchecked.

As a result, the set temperature tended to be higher in orderto obtain comfort at floor level.

Inlet temperature sensor

Area measured by cassette model without "I-See Sensor"

37ºC

25ºC

13ºC

Without “I-See Sensor”.Set temperature is23ºC (in Heating)

e.g. To achieve a sensible temperature of 20ºC, the set temperature must be as high as 23ºC

Inlet temperature sensor

2.7m

Area measured by the cassette model equipped with "I-See Sensor"360°

sensing

37ºC

25ºC

13ºC

With the “I-See Sensor” plus automatic airflowadjustment mode.Set temperature is 20ºC (in Heating)

e.g. With the set temperature at 20ºC, a sensible temperature of 20ºC at floor level can be obtained.

With “I-See Sensor”... both the floor temperature and inlet temperature are measured.

The New 4-Way Blow Ceiling Cassette with the “I-See Sensor” simultaneously measures the floor and inlet temperatures, providing improved comfort to occupants and increased energy savings.

Page 61

Page 63: 2008 Product Catalogue

The adaptable Mr Slim range

Available in a variety of options, the Mr Slim range

fits in wherever it’s needed. Indoor units can be

four way blow cassettes, ducted,

wall or ceiling mounted. Up to four indoor

units can then be connected to a single outdoor unit

providing the ideal air conditioning solution.

Designed to f it anywhere

Simple technologyat its best

Systems marked with the ECA logo have an energy label of A or B, are registered on theEnergy Technology List and hence qualify for 100% first year enhanced capital allowances(whole system cost and ‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk

Nominal conditions cooling: indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.Nominal conditions heating: indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. Winter; indoor 21˚C DB; outdoor -1˚C WB.

Page 62

Page 64: 2008 Product Catalogue

Contents

PKA-RP Power Inverter Heat Pump, Wall Mounted System

PKA-RP Standard Inverter Heat Pump, Wall Mounted System

PKA-RP Heat Pump, Wall Mounted System

SEZ-KD-VA Inverter Heat Pump, Ceiling Concealed Ducted System

PEAD-RP Power Inverter Heat Pump, Ceiling Concealed Ducted System

PEAD-RP Standard Inverter Heat Pump, Ceiling Concealed Ducted System

PEAD-RP Heat Pump, Ceiling Concealed Ducted System

PEA-RP-GA Power Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System

PEA-RP-GA Standard Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System

SLZ-KA-VA Inverter Heat Pump, 600x600 4-Way Blow Ceiling Cassette System

PLA-RP Power Inverter Heat Pump, 4-Way Blow Ceiling Cassette System

PLA-RP Standard Inverter Heat Pump, 4-Way Blow Ceiling Cassette System

PLA-RP Heat Pump, 4-Way Blow Ceiling Cassette System

PCA-RP Power Inverter Heat Pump, Ceiling Suspended System

PCA-RP Standard Inverter Heat Pump, Ceiling Suspended System

PCA-RP Heat Pump, Ceiling Suspended System

PCA-RP-HA Power Inverter Heat Pump, Stainless Steel Ceiling Suspended System

PCA-RP-HA Standard Inverter Heat Pump, Stainless Steel Ceiling Suspended System

PCA-RP-HA Heat Pump, Stainless Steel Ceiling Suspended System

PSA-RP Power Inverter Heat Pump, Floor Standing System

PSA-RP Standard Inverter Heat Pump, Floor Standing System

PSA-RP Heat Pump, Floor Standing System

PHV DXE Heat Pump, Air Curtain

Mr Slim Multi-Split Systems Heat Pump

Outdoor Units

Air Handling Unit Controller

Mr Slim Accessories / Optional Extras

64

66

68

70

72

74

76

78

80

82

84

86

88

90

92

94

96

98

100

102

104

106

108

110

112

115

116

Page 63

Page 65: 2008 Product Catalogue

PKA-RP - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi1-Mi2-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) – HRC (A)

INTERCONNECTING CABLE No. CORES

PKA-RP35GAL

3.6 (1.6-5.2)

3.6 (1.6-4.5)

3.05 (1.35-4.4)

3.25 (1.45-4.05)

0.87

3.41 / 3.50

B / A

9-10-11-12

12.7 (1/2”)

6.35 (1/4”)

36-38-41-43

990

235

340

16

Fed by Outdoor Unit

Single

6

4

PKA-RP50FAL2

6.0 (2.5-7.3)

5.0 (2.3-5.6)

5.1 (2.15-6.2)

4.5 (2.05-5.05)

0.86

3.41 / 3.01

B / B

15-20

12.7 (1/2”)

6.35 (1/4”)

39-45

1400

235

340

24

Fed by Outdoor Unit

Single

6

4

PKA-RP60FAL

7.0 (2.8-8.2)

6.0 (2.7-6.7)

5.95 (2.4-6.95)

5.4 (2.45-6.05)

0.83

3.48 / 3.87

B / A

15-20

15.88 (5/8”)

9.52 (3/8”)

39-45

1400

235

340

24

Fed by Outdoor Unit

Single

6

4

PKA-RP71FAL

7.6 (3.5-10.2)

7.1 (3.3-8.1)

6.45 (3.0-8.65)

6.4 (2.95-7.3)

0.77

3.41 / 3.59

B / A

15-20

15.88 (5/8”)

9.52 (3/8”)

39-45

1400

235

340

24

Fed by Outdoor Unit

Single

6

4

PKA-RP100FAL

11.2 (4.5-14.0)

10.0 (4.9-11.4)

9.5 (3.85-11.9)

9.0 (4.4-10.25)

0.77

3.45 / 3.41

B / A

22-28

15.88 (5/8”)

9.52 (3/8”)

41-46

1680

235

340

28

Fed by Outdoor Unit

Single

6

4

PUHZ-RP - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

PUHZ-RP35VHA3

46 / 44

42

800

300 + 23

600

220-240v, 50Hz

Single

1.06 / 1.03

0.94 / 0.86

5

4.56 / 4.34 [13]

-

16

3

50

30

2.5

PUHZ-RP50VHA3

46 / 44

42

800

300 + 23

600

220-240v, 50Hz

Single

1.76 / 1.66

1.57 / 1.41

5

6.9 / 6.59 [13]

-

16

3

50

30

2.5

PUHZ-RP60VHA3

48 / 47

68

950

330 + 30

943

220-240v, 50Hz

Single

2.01 / 1.55

1.79 / 1.32

5

7.93 / 7.04 [19]

-

25

3

50

30

3.5

PUHZ-RP71VHA3

48 / 47

68

950

330 + 30

943

220-240v, 50Hz

Single

2.23 / 1.98

2.00 / 1.68

5

10.17 / 8.47 [19]

-

25

3

50

30

3.5

PUHZ-RP100VHA3/YHA3

51 / 49

116 / 130

950

330 + 30

1350

220-240v, 50Hz / 380-415,50Hz

Single / 3

3.25 / 2.93

2.89 / 2.49

5

12.91 / 13.05 [28]

4.55 / 4.60 [13]

32 / 16

3 / 5

75

30

5.0

Wall Mounted System� Adjustable louvres for uniform air distribution

� Internal pipe connection to wall mounted unit for easy and neat installation

PKA-RP Power Inverter Heat Pump

Technical Information

Page 64

Page 66: 2008 Product Catalogue

INDOOR UNIT PKA-RP35GAL

INDOOR UNIT PKA-RP50-71FAL(2)

INDOOR UNIT PKA-RP100FAL

Mr

Slim

Ran

ge 2

008

Lower Side View >

Left Side View > Front View > < Right Side View

Lower Side View >

Left Side View > Front View > < Right Side View

Front View >

Lower Side View >

Left Side View > Right Side View >

PKA

-RP

Pow

er In

vert

er H

eat

Pum

p

Dimensions

Page 65

Page 67: 2008 Product Catalogue

PKA-RP - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi1-Mi2-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PKA-RP100FAL

11.2 (4.5-12.5)

9.4 (4.9-11.2)

9.5 (3.85-10.65)

8.45 (4.4-10.1)

0.79

3.21 / 3.01

C / B

22-28

15.88 (5/8”)

9.52 (3/8”)

41-46

1680

235

340

28

Fed by Outdoor Unit

Single

6

4

PUHZ-P - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 20m

PUHZ-P100VHA2

54 / 50

75

950

330 + 30

943

220-240v, 50Hz

Single

3.49 / 3.12

3.11 / 2.65

4

13.14 / 12.78 [28]

32

3

50

30

2.7

Wall Mounted System

� Adjustable louvres for uniform air distribution

� Internal pipe connection to wall mounted unit for easy and neat installation

PKA-RP Standard Inverter Heat Pump

The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the more expensive Power Inverter range.

Technical Information

Page 66

Page 68: 2008 Product Catalogue

INDOOR UNIT PKA-RP100FAL

Lower Side View >

Left Side View > Front View > < Right Side View

Mr

Slim

Ran

ge 2

008

PKA

-RP

Stan

dard

Inve

rter

Hea

t Pu

mp

Dimensions

Page 67

Page 69: 2008 Product Catalogue

PKA-RP - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi1-Mi2-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PKA-RP100FAL

11.5

9.8

9.8

8.8

0.77

22-28

15.88 (5/8”)

9.52 (3/8”)

41-46

1680

235

340

28

Fed by Outdoor Unit

Single

6

4

Wall Mounted System

PKA-RP Heat Pump

PUH-P - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

PUH-P100YHA

52 / 50

94

950

330 + 30

943

380-415v, 50Hz

3

3.47 / 3.50

3.09 / 2.98

45

5.7 / 5.91 [11.8]

20

5

50

50

4.4

Technical Information

� Adjustable louvres for uniform air distribution

� Internal pipe connection to wall mounted unit for easy and neat installation

The Heat Pump system provides a low cost alternative to three phase Power Inverter systems.

Page 68

Page 70: 2008 Product Catalogue

INDOOR UNIT PKA-RP100FAL

Lower Side View >

Left Side View > Front View > < Right Side View

Mr

Slim

Ran

ge 2

008

PKA

-RP

Hea

t Pu

mp

Dimensions

Page 69

Page 71: 2008 Product Catalogue

SEZ-KD-VA - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi-Hi

EXTERNAL STATIC PRESSURE Pa Lo-Mi1-Mi2-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

SUZ-KA-VA - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) (Lo-Hi) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. CORES

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 7m

SEZ-KD25VA

3.0 (0.9-4.5)

2.5 (0.9-3.2)

2.5 (0.75-3.75)

2.5 (0.9-3.15)

0.80

3.61 / 3.21

A / A

5.5-7.0-9.0

5-15-35-50

9.52 (3/8”)

6.35 (1/4”)

23-26-30

790

700

200

18

Fed by Outdoor Unit

Single

6

4

SEZ-KD35VA

4.0 (0.9-5.0)

3.5 (1.0-3.9)

3.3 (0.75-4.15)

3.45 (1.0-3.85)

0.78

3.61 / 3.21

A / A

7-9-11

5-15-35-50

9.52 (3/8”)

6.35 (1/4”)

23-28-33

990

700

200

21

Fed by Outdoor Unit

Single

6

4

SEZ-KD50VA

6.0 (1.1-7.2)

5.0 (1.1-5.6)

5.0 (0.9-6.0)

4.95 (1.1-5.55)

0.76

3.21 / 2.81

C / C

10-12.5-15

5-15-35-50

12.7 (1/2”)

6.35 (1/4”)

30-34-37

990

700

200

23

Fed by Outdoor Unit

Single

6

4

SEZ-KD60VA

7.0 (0.9-8.0)

5.5 (1.1-6.3)

5.8 (0.75-6.65)

5.45 (1.1-6.25)

0.79

3.41 / 2.91

B / C

12-15-18

5-15-35-50

15.88 (5/8”)

6.35 (1/4”)

30-34-38

1190

700

200

27

Fed by Outdoor Unit

Single

6

4

SEZ-KD71VA

8.1 (0.9-10.4)

7.1 (0.9-8.3)

6.75 (0.75-8.65)

7.05 (0.9-8.25)

0.74

3.42 / 2.81

B / C

12-16-20

5-15-35-50

15.88 (5/8”)

9.52 (3/8”)

30-35-40

1190

700

200

27

Fed by Outdoor Unit

Single

6

4

SUZ-KA25VA

46 / 46

33

800

285

550

220-240v, 50Hz

0.83 / 0.778

0.76 / 0.62

3.65

4.04 / 3.44 [8.16]

16

3

20

12

0.9

SUZ-KA35VA

48 / 47

37

800

285

550

220-240v, 50Hz

1.108 / 1.09

1.01 / 0.87

4.75

5.21 / 5.01 [9.18]

16

3

20

12

1.05

SUZ-KA50VA

53-55 / 51-53

53

840

330

850

220-240v, 50Hz

1.87 / 1.78

1.70 / 1.42

6.75

6.98 / 7.38 [16]

25

3

30

30

1.6

SUZ-KA60VA

53-55 / 51-53

53

840

330

850

220-240v, 50Hz

2.05 / 1.89

1.87 / 1.51

9.75

10.38 / 8.98 [16]

25

3

30

30

1.8

SUZ-KA71VA

53-55 / 51-53

58

840

330

850

220-240v, 50Hz

2.37 / 2.53

2.15 / 2.02

10.3

10.74 / 11.14 [16]

25

3

30

30

2.0

Ceiling Concealed Ducted System

SEZ-KD-VA Inverter Heat Pump

Designed for homes, offices, restaurants or shops, the SEZ-KD-VA series operates at low noise levels. Its new improved low unit height and lightweight design also help to make installation easier and more convenient.

Technical Information

Note: Optional interfaces for M-NET connectivity (MAC-399IF) and group control, fault/run (MAC-397IF) are available. Please see accessories / optional extras section.

Page 70

Page 72: 2008 Product Catalogue

Upper View >

INDOOR UNIT SEZ-KD25-71VA

Front View >

Mr

Slim

Ran

ge 2

008

SEZ

-KD

-VA

Inve

rter

Hea

t Pu

mp

Dimensions

Models A B C D E F

Size 25 700 752 798 660 7 600

Size 35-50 900 952 998 860 9 800

Size 60-71 1100 1152 1198 1060 11 1000

Page 71

Side View >

Page 73: 2008 Product Catalogue

PEAD-RP - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

EXTERNAL STATIC PRESSURE (Pa) Lo-Hi

NOISE (dBA) Lo-Hi (*4)

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PEAD-RP140EA

16.0 (5.0-18.0)

14.0 (5.5-15.3)

13.6 (4.25-15.3)

12.6 (4.95-13.75)

0.83

3.41 / 3.01

B / B

36.5-46

15.88 (5/8”)

9.52 (3/8”)

70-130*3

46-51 (47-53)

1715

740

325

70

Fed by Outdoor Unit

Single

6

4

PEAD-RP125EA

14.0 (5.0-16.0)

12.5 (5.5-14.0)

11.9 (4.25-13.6)

11.25 (4.95-12.6)

0.82

3.61 / 3.21

A / A

33.5-42

15.88 (5/8”)

9.52 (3/8”)

70-130*3

44-50 (46-52)

1415

740

325

65

Fed by Outdoor Unit

Single

6

4

PEAD-RP100EA2

11.2 (4.5-14.0)

10.0 (4.9-11.4)

9.5 (3.85-11.9)

9.0 (4.4-10.25)

0.86

3.51 / 3.27

B / A

33.5-42

15.88 (5/8”)

9.52 (3/8”)

70-130*2

44-50 (46-52)

1415

740

325

65

Fed by Outdoor Unit

Single

6

4

PEAD-RP71EA

8.0 (3.5-10.2)

7.1 (3.3-8.1)

6.8 (3.0-8.65)

6.4 (2.95-7.3)

0.83

3.42 / 3.30

B / A

20-25

15.88 (5/8”)

9.52 (3/8”)

70-130*1

37-41 (40-45)

1175

740

325

44

Fed by Outdoor Unit

Single

6

4

PEAD-RP60EA

7.0 (2.8-8.2)

6.0 (2.7-6.7)

5.95 (2.4-6.95)

5.4 (2.45-6.05)

0.79

3.68 / 3.23

A / A

17-21

15.88 (5/8”)

9.52 (3/8”)

30-70

37-41 (39-46)

1175

700

295

42

Fed by Outdoor Unit

Single

6

4

PEAD-RP50EA

6.0 (2.5-7.3)

4.9 (2.3-5.6)

5.1 (2.15-6.2)

4.4 (2.05-5.05)

0.82

3.64 / 3.22

A / A

13.5-17

12.7 (1/2”)

6.35 (1/4”)

30-70

36-40 (38-44)

935

700

295

35

Fed by Outdoor Unit

Single

6

4

PEAD-RP35EA2

4.1 (1.6-5.2)

3.6 (1.6-4.5)

3.5 (1.35-4.4)

3.25 (1.45-4.05)

0.89

3.41 / 3.21

B / A

13.5-17

12.7 (1/2”)

6.35 (1/4”)

30-70

36-40 (38-44)

935

700

295

33

Fed by Outdoor Unit

Single

6

4

PUHZ-RP35VHA3

46 / 44

42

800

300 + 23

600

220-240v, 50Hz

Single

1.20 / 1.12

1.05 / 0.95

5

4.84 / 4.62 [13]

-

16

3

50

30

2.5

PUHZ-RP50VHA3

46 / 44

42

800

300 + 23

600

220-240v, 50Hz

Single

1.65 / 1.52

1.47 / 1.29

5

7.08 / 6.77 [13]

-

16

3

50

30

2.5

PUHZ-RP60VHA3

48 / 47

68

950

330 + 30

943

220-240v, 50Hz

Single

1.90 / 1.86

1.69 / 1.58

5

8.2 / 7.31 [19]

-

25

3

50

30

3.5

PUHZ-RP71VHA3

48 / 47

68

950

330 + 30

943

220-240v, 50Hz

Single

2.34 / 2.15

2.08 / 1.83

5

11.29 / 9.59 [19]

-

25

3

50

30

3.5

PUHZ-RP100VHA3/YHA3

51 / 49

116 / 130

950

330 + 30

1350

220-240v, 50Hz / 380-415,50Hz

Single / 3

3.19 / 3.06

2.84 / 2.60

5

15.01 / 15.15 [28]

6.65 / 6.70 [13]

32 / 16

3 / 5

75

30

5.0

PUHZ-RP125VHA2/YHA2

52 / 50

116 / 130

950

330 + 30

1350

220-240v, 50Hz / 380-415,50Hz

Single / 3

3.88 / 3.89

3.45 / 3.31

5

18.6 / 18.15 [28]

7.82 / 7.66 [13]

32 / 16

3 / 5

75

30

5.0

PUHZ-RP140VHA2/YHA2

52 / 50

116 / 130

950

330 + 30

1350

220-240v, 50Hz / 380-415,50Hz

Single / 3

4.69 / 4.65

4.17 / 3.95

5

22.61 / 22.34 [29.5]

9.15 / 9.06 [13]

40 / 16

3 / 5

75

30

5.0

PUHZ-RP - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

Ceiling Concealed Ducted System

PEAD-RP Power Inverter Heat Pump

Notes: External static pressure - (35-60: 30 + 70Pa connections as standard) / (71-140: 130Pa optional fan motor - *1 PAC-SK005MT-F, *2 PAC-SK004MT-F, *3 PAC-SK003MT-F).*4 70Pa (35-60) / 130Pa optional fan motor (71-140).

Technical Information

Page 72

Page 74: 2008 Product Catalogue

Models A B C D E

Size 35-50 772 305 - 830 804

Size 60 1012 280 290 1070 1044

INDOOR UNIT PEAD-RP35-60EA(2)

INDOOR UNIT PEAD-RP71-140EA(2)

Models A B C D E

Size 71 1012 280 290 1070 1044

Size 100-125 1252 360 370 1310 1284

Size 140 1552 460 470 1610 1584

Side View >

Upper View >

Front View >

Upper View > Front View >

Side View >

Mr

Slim

Ran

ge 2

008

PEA

D-R

PPo

wer

Inve

rter

Hea

t Pu

mp

Dimensions

Page 73

Page 75: 2008 Product Catalogue

PEAD-RP - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

EXTERNAL STATIC PRESSURE (Pa) Lo-Hi

NOISE (dBA) Lo-Hi (*4)

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PEAD-RP140EA

16.0 (5.0-18.0)

13.6 (5.5-15.0)

13.6 (4.25-15.3)

12.25 (4.95-13.5)

0.84

3.21 / 2.61

C / D

36.5-46

15.88 (5/8”)

9.52 (3/8”)

70-130*3

46-51 (47-53)

1715

740

325

70

Fed by Outdoor Unit

Single

6

4

PEAD-RP125EA

14.0 (5.0-16.0)

12.3 (5.5-14.0)

11.9 (4.25-13.6)

11.05 (4.95-12.6)

0.83

3.41 / 2.81

B / C

33.5-42

15.88 (5/8”)

9.52 (3/8”)

70-130*3

44-50 (46-52)

1415

740

325

65

Fed by Outdoor Unit

Single

6

4

PEAD-RP100EA2

11.2 (4.5-12.5)

9.4 (4.9-11.2)

9.5 (3.85-10.65)

8.45 (4.4-10.1)

0.86

3.41 / 3.01

B / B

33.5-42

15.88 (5/8”)

9.52 (3/8”)

70-130*2

44-50 (46-52)

1415

740

325

65

Fed by Outdoor Unit

Single

6

4

PEAD-RP71EA

8.0 (0.9-10.2)

7.1 (0.9-8.1)

6.65 (0.75-8.5)

7.05 (0.9-8.05)

0.81

3.21 / 2.81

C / C

20-25

15.88 (5/8”)

9.52 (3/8”)

70-130*1

37-41 (40-45)

1175

740

325

44

Fed by Outdoor Unit

Single

6

4

PEAD-RP60EA

7.0 (0.9-8.0)

6.0 (1.1-6.3)

5.8 (0.75-6.65)

5.95 (1.1-6.25)

0.80

3.38 / 2.93

C / C

17-21

15.88 (5/8”)

6.35 (1/4”)

30-70

37-41 (39-46)

1175

700

295

42

Fed by Outdoor Unit

Single

6

4

PEAD-RP50EA

5.9 (0.9-7.2)

4.9 (1.1-5.6)

4.9 (0.75-6.0)

4.85 (1.1-5.55)

0.79

3.49 / 2.82

B / C

13.5-17

12.7 (1/2”)

6.35 (1/4”)

30-70

36-40 (38-44)

935

700

295

35

Fed by Outdoor Unit

Single

6

4

PEAD-RP35EA2

4.1 (0.9-5.0)

3.6 (1.0-3.9)

3.4 (0.75-4.15)

3.55 (1.0-3.85)

0.90

3.63 / 3.21

A / A

13.5-17

9.52 (3/8”)

6.35 (1/4”)

30-70

36-40 (38-44)

935

700

295

33

Fed by Outdoor Unit

Single

6

4

SUZ-KA35VA

48 / 47

37

800

285

550

220-240v, 50Hz

Single

1.13 / 1.12

1.03 / 0.90

4.75

5.36 / 5.16 [9.18]

16

3

20

12

1.05

SUZ-KA50VA

53-55 / 51-53

53

840

330

850

220-240v, 50Hz

Single

1.69 / 1.74

1.54 / 1.39

6.75

6.96 / 7.36 [16]

25

3

30

30

1.6

SUZ-KA60VA

53-55 / 51-53

53

840

330

850

220-240v, 50Hz

Single

2.07 / 2.05

1.88 / 1.64

9.75

10.45 / 9.05 [16]

25

3

30

30

1.8

SUZ-KA71VA

53-55 / 51-53

58

840

330

850

220-240v, 50Hz

Single

2.49 / 2.53

2.27 / 2.02

10.3

11.45 / 11.85 [16]

25

3

30

30

2.0

PUHZ-P100VHA2

54 / 50

75

950

330 + 30

943

220-240v, 50Hz

Single

3.28 / 3.12

2.92 / 2.65

4

15.24 / 14.88 [28]

32

3

50

30

2.7

PUHZ-P125VHA2

55 / 51

99

950

330 + 30

1350

220-240v, 50Hz

Single

4.11 / 4.38

3.66 / 3.72

14

19.36 / 19.99 [28]

32

3

50

30

4.5

PUHZ-P140VHA2

56 / 52

99

950

330 + 30

1350

220-240v, 50Hz

Single

4.98 / 5.21

4.43 / 4.43

14

24.00 / 25.17 [29.5]

40

3

50

30

4.5

SUZ-KA / PUHZ-P - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) (Lo-Hi) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg)

Ceiling Concealed Ducted System

PEAD-RP Standard Inverter Heat Pump

Notes: External static pressure - (35-60: 30 + 70Pa connections as standard) / (71-140: 130Pa optional fan motor - *1 PAC-SK005MT-F, *2 PAC-SK004MT-F, *3 PAC-SK003MT-F).*4 70Pa (35-60) / 130Pa optional fan motor (71-140).

The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the more expensive Power Inverter range.

Notes: All units charged to 7m (35-71), 20m (100) and 30m (125-140) pipe length.

Technical Information

Page 74

Page 76: 2008 Product Catalogue

Models A B C D E

Size 35-50 772 305 - 830 804

Size 60 1012 280 290 1070 1044

INDOOR UNIT PEAD-RP35-60EA(2)

INDOOR UNIT PEAD-RP71-140EA(2)

Models A B C D E

Size 71 1012 280 290 1070 1044

Size 100-125 1252 360 370 1310 1284

Size 140 1552 460 470 1610 1584

Side View >

Upper View >

Front View >

Upper View > Front View >

Side View >

Mr

Slim

Ran

ge 2

008

PEA

D-R

PSt

anda

rd In

vert

er H

eat

Pum

p

Dimensions

Page 75

Page 77: 2008 Product Catalogue

PEAD-RP - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

EXTERNAL STATIC PRESSURE (Pa) Lo-Hi

NOISE (dBA) Lo-Hi (*3)

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PEAD-RP100EA2

11.5

10.0

9.8

9.0

0.86

33.5-42

15.88 (5/8”)

9.52 (3/8”)

70-130*1

44-50 (46-52)

1415

740

325

65

Fed by Outdoor Unit

Single

6

4

PEAD-RP125EA

14.3

12.3

12.2

11.05

0.82

33.5-42

15.88 (5/8”)

9.52 (3/8”)

70-130*2

44-50 (46-52)

1415

740

325

65

Fed by Outdoor Unit

Single

6

4

PEAD-RP140EA

16.7

14.2

14.2

12.8

0.83

36.5-46

15.88 (5/8”)

9.52 (3/8”)

70-130*2

46-51 (47-53)

1715

740

325

70

Fed by Outdoor Unit

Single

6

4

Ceiling Concealed Ducted System

PEAD-RP Heat Pump

PUH-P100YHA

52 / 50

94

950

330 + 30

943

380-415v, 50Hz

3

3.42 / 3.69

3.04 / 3.14

45

7.8 / 8.01 [13.9]

20

5

50

50

4.4

PUH-P125YHA

52 / 50

131

950

330 + 30

1350

380-415v, 50Hz

3

4.32 / 4.41

3.85 / 3.75

70

9.19 / 9.41 [17.8]

20

5

50

50

5.0

PUH-P140YHA

53 / 51

131

950

330 + 30

1350

380-415v, 50Hz

3

5.28 / 5.63

4.70 / 4.79

85

11.14 / 11.24 [21.5]

25

5

50

50

5.0

PUH-P - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

Notes: External static pressure - (100-140: 130Pa optional fan motor - *1 PAC-SK004MT-F, *2 PAC-SK003MT-F). *3 130Pa optional fan motor (100-140).

Technical Information

The Heat Pump system provides a low cost alternative to three phase Power Inverter systems.

Page 76

Page 78: 2008 Product Catalogue

INDOOR UNIT PEAD-RP100-140EA(2)

Models A B C D E

Size 100-125 1252 360 370 1310 1284

Size 140 1552 460 470 1610 1584

Upper View >

Front View >

Side View >

Mr

Slim

Ran

ge 2

008

PEA

D-R

P H

eat

Pum

p

Dimensions

Page 77

Page 79: 2008 Product Catalogue

PEA-RP-GA - INDOOR UNITSMODEL REFERENCECAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

EXTERNAL STATIC PRESSURE (Pa)

NOISE (dBA) Lo-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

POWER INPUT (kW) (nominal)

(UK)

STARTING CURRENT (A)

RUNNING CURRENT (A) [Max]

FUSE RATING (BS88) – HRC (A)

MAINS CABLE No. Cores

INTERCONNECTING CABLE No. CORES

PUHZ-RP-YHA2 - OUTDOOR UNITSMODEL REFERENCENOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

RUNNING CURRENT (A) [Max] Heating/Cooling

FUSE RATING (BS88) – HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

PEA-RP200GA

22.4 (9.5-25.0)

19.0 (9.0-22.4)

19.05 (8.1-21.25)

17.1 (8.3-21.15)

0.81

3.45 / 2.84

B / C

52-65

28.58 (1 1/8”)

9.52 (3/8”)

150

48-51

1400

634

400

70

380-415v, 50Hz

3

1.00

0.89

5.62.0 [2.4]

6

5

3

PEA-RP250GA

27.0 (12.5-31.5)

22.0 (11.2-28.0)

22.95 (10.65-26.8)

19.8 (10.3-25.2)

0.86

3.29 / 2.64

C / D

64-80

28.58 (1 1/8”)

12.7 (1/2”)

150

49-52

1600

634

400

77

380-415v, 50Hz

3

1.18

1.05

5.6

2.3 [2.8]

6

5

3

PUHZ-RP200YHA2

59 / 58

135

950

330+30

1350

380-415v, 50Hz

3

5.5 / 5.7

4.9 / 4.85

5

8.9 / 7.7 [19]

32

5

120

30

6.5

PUHZ-RP250YHA2

59 / 58

136

950

330+30

1350

330-415v, 50Hz

3

7.02 / 7.16

6.25 / 6.09

5

11.1 / 9.5 [21]

32

5

120

30

7.1

PEA-RP400GA

44.8 (18.0-50.0)

38.0 (18.0-44.8)

38.1 (15.3-42.5)

34.95 (16.55-41.2)

0.75

3.56 / 2.93

B / C

120

28.58 (1 1/8”) x2

9.52 (3/8”) x2

150

52

1947

764

595

130

380-415v, 50Hz

3

1.55

1.38

8.7

3.8 [4.6]

10

5

3

PEA-RP500GA

54.0 (25.0-63.0)

44.0 (22.4-56.0)

45.9 (21.25-53.55)

40.5 (20.6-51.5)

0.77

3.20 / 2.56

D / E

160

28.58 (1 1/8”) x2

12.7 (1/2”) x2

150

53

1947

764

595

133

380-415v, 50Hz

3

2.84

2.53

10

5.4 [6.5]

10

5

3

PUHZ-RP200YHA2 x2

59 / 58

135

950

330+30

1350

380-415v, 50Hz

3

5.5 / 5.7

4.9 / 4.85

5

8.9 / 7.7 [19]

32

5

120 per outdoor

30

6.5

PUHZ-RP250YHA2 x2

59 / 58

136

950

330+30

1350

330-415v, 50Hz

3

7.02 / 7.16

6.25 / 6.09

5

11.1 / 9.5 [21]

32

5

120 per outdoor

30

7.1

Large Capacity Ceiling Concealed Ducted System

PEA-RP-GA Power Inverter Heat Pump

� Twin, triple or quadruple configurations on one outdoor unit, utilising Mr Slim indoor units

� Static pressure of up to 150Pa

� Outdoor unit size reduced by approx 33%, with height being reduced by 66% (compared to previous model)

Technical Information

Page 78

Page 80: 2008 Product Catalogue

INDOOR UNIT PEA-RP200GA

Upper View >

Front View >

Side View >

INDOOR UNIT PEA-RP250GA

INDOOR UNIT PEA-RP400-500GA

Upper View >

Front View >

Side View >

Upper View >

Front View >

Side View >

Mr

Slim

Ran

ge 2

008

PEA

-RP-

GA

Pow

er In

vert

er H

eat

Pum

p

Dimensions

Page 79

Page 81: 2008 Product Catalogue

PEA-RP-GA - INDOOR UNITSMODEL REFERENCECAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

EXTERNAL STATIC PRESSURE (Pa)

NOISE (dBA) Lo-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

POWER INPUT (kW) (nominal)

(UK)

STARTING CURRENT (A)

RUNNING CURRENT (A) [Max]

FUSE RATING (BS88) – HRC (A)

MAINS CABLE No. Cores

INTERCONNECTING CABLE No. CORES

PEA-RP200GA

22.4 (9.5-25.0)

19.0 (9.0-22.4)

19.05 (8.1-21.25)

17.1 (8.3-21.15)

0.81

3.04 / 2.64

D / D

52-65

28.58 (1 1/8”)

9.52 (3/8”)

150

48-51

1400

634

400

70

380-415v, 50Hz

3

1.00

0.89

5.6

2.0 [2.4]

6

5

3

PEA-RP250GA

27.0 (12.5-31.5)

22.0 (11.2-28.0)

22.95 (10.65-26.8)

19.8 (10.3-25.2)

0.86

3.19 / 2.61

D / D

64-80

28.58 (1 1/8”)

12.7 (1/2”)

150

49-52

1600

634

400

77

380-415v, 50Hz

3

1.18

1.05

5.6

2.3 [2.8]

6

5

3

PUHZ-P200YHA

59 / 59

126

950

330+30

1350

380-415v, 50Hz

3

6.36 / 6.21

5.66 / 5.28

5

9.88 / 9.47 [19]

32

5

70

30

5.8

PUHZ-P250YHA

59 / 59

133

950

330+30

1350

330-415v, 50Hz

3

7.29 / 7.26

6.49 / 6.17

5

12.0 / 11.0 [21]

32

5

70

30

7.1

PEA-RP400GA

44.8 (19.0-50.0)

38.0 (18.0-44.8)

38.1 (16.15-42.5)

34.95 (16.55-41.2)

0.75

3.14 / 2.72

D / D

120

28.58 (1 1/8”) x2

9.52 (3/8”) x2

150

52

1947

764

595

130

380-415v, 50Hz

3

1.55

1.38

8.7

3.8 [4.6]

10

5

3

PEA-RP500GA

54.0 (25.0-63.0)

44.0 (22.4-56.0)

45.9 (21.25-53.55)

40.5 (20.6-51.5)

0.77

3.10 / 2.53

D / E

160

28.58 (1 1/8”) x2

12.7 (1/2”) x2

150

53

1947

764

595

133

380-415v, 50Hz

3

2.84

2.53

10

5.4 [ 6.5]

10

5

3

PUHZ-P200YHA x2

59 / 59

126

950

330+30

1350

380-415v, 50Hz

3

6.36 / 6.21

5.66 / 5.28

5

9.88 / 9.47 [19]

32

5

70 per outdoor

30

5.8

PUHZ-P250YHA x2

59 / 59

133

950

330+30

1350

330-415v, 50Hz

3

7.29 / 7.26

6.49 / 6.17

5

12.0 / 11.0 [21]

32

5

70 per outdoor

30

7.1

PUHZ-P-YHA - OUTDOOR UNITSMODEL REFERENCENOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

RUNNING CURRENT (A) [Max] Heating/Cooling

FUSE RATING (BS88) – HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

Large Capacity Ceiling Concealed Ducted System

PEA-RP-GA Standard Inverter Heat Pump

� Twin, triple or quadruple configurations on one outdoor unit, utilising Mr Slim indoor units

� Static pressure of up to 150Pa

Technical Information

Page 80

The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the more expensive Power Inverter range.

Page 82: 2008 Product Catalogue

INDOOR UNIT PEA-RP200GA

Upper View >

Front View >

Side View >

INDOOR UNIT PEA-RP250GA

INDOOR UNIT PEA-RP400-500GA

Upper View >

Front View >

Side View >

Upper View >

Front View >

Side View >

Mr

Slim

Ran

ge 2

008

PEA

-RP-

GA

Stan

dard

Inve

rter

Hea

t Pu

mp

Dimensions

Page 81

Page 83: 2008 Product Catalogue

600x600 4-Way Blow Ceiling Cassette System

SLZ-KA-VA - INDOOR UNITS

SLZ-KA-VA Inverter Heat Pump

The SLZ-KA-VA series is perfect for both residential andsmall business applications, as it offers inverter technologyalongside quiet operation. The compact size of this unit is ideal for 600 by 600mm ceilings and with a depth of208mm, this lightweight unit makes installation a breeze.This unit also comes complete with a long life filter that will last for approximately 2,500 hours.

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi-Hi

DIMENSIONS (mm) (grille) Width

Depth

Height

WEIGHT (kg) Unit

Grille

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

SUZ-KA-VA - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) (Lo-Hi) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. CORES

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 7m

SLZ-KA25VA

3.0 (0.9-4.5)

2.5 (0.9-3.2)

2.5 (0.75-3.75)

2.5 (0.9-3.15)

0.86

3.61 / 3.62

A / A

8-9-10

9.52 (3/8”)

6.35 (1/4”)

28-31-37

570 (650)

570 (650)

208 (20)

16.5

3

Fed by Outdoor Unit

Single

6

4

SLZ-KA35VA

4.0 (0.9-5.0)

3.5 (1.0-3.9)

3.3 (0.75-4.15)

3.45 (1.0-3.85)

0.77

3.64 / 3.30

A / A

8-9-11

9.52 (3/8”)

6.35 (1/4”)

29-33-38

570 (650)

570 (650)

208 (20)

16.5

3

Fed by Outdoor Unit

Single

6

4

SLZ-KA50VA

5.0 (0.9-6.5)

4.6 (1.1-5.2)

4.15 (0.75-5.4)

4.55 (1.1-5.15)

0.68

3.23 / 2.82

C / C

8-9-11

12.7 (1/2”)

6.35 (1/4”)

30-34-39

570 (650)

570 (650)

208 (20)

16.5

3

Fed by Outdoor Unit

Single

6

4

SUZ-KA25VA

46 / 46

33

800

285

550

220-240v, 50Hz

0.83 / 0.69

0.76 / 0.55

3.65

4.0 / 3.4 [8.16]

16

3

20

12

0.9

SUZ-KA35VA

48 / 47

37

800

285

550

220-240v, 50Hz

1.10 / 1.06

1.00 / 0.85

4.75

5.15 / 4.95 [9.18]

16

3

20

12

1.05

SUZ-KA50VA

53-55 / 51-53

53

840

330

850

220-240v, 50Hz

1.55 / 1.63

1.41 / 1.30

6.75

7.0 / 7.4 [16]

25

3

30

30

1.6

Technical InformationNote: Optional interfaces for M-NET connectivity (MAC-399IF) and group control, fault/run (MAC-397IF) are available. Please see accessories / optional extras section.

Page 82

Page 84: 2008 Product Catalogue

Lower View >

INDOOR UNIT SLZ-KA25-50VA

Side View >

Mr

Slim

Ran

ge 2

008

SLZ

-KA

-VA

Inve

rter

Hea

t Pu

mp

Dimensions

Page 83

Page 85: 2008 Product Catalogue

� Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed� Reduced draft air distribution, with independent vane control� Filter lowering operation down to 4m (optional PLP-6BAJ grille required)� Optional ‘I See Sensor' for energy saving and smooth temperature

control throughout the room

PLA-RP - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal) [3 Phase]

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi1-Mi2-Hi

DIMENSIONS (mm) Width

(Grille) Depth

Height

WEIGHT (kg) Unit

Panel

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

GRILLE REFERENCE

WIRED REMOTE CONTROLLER REFERENCE

PLA-RP140BA

16.0 (5.0-18.0)

14.0 (5.5-15.3)

13.6 (4.25-15.3)

12.6 (4.95-13.75)

0.71

3.61 / 3.01

A / B

24-26-29-32

15.88 (5/8”)

9.52 (3/8”)

36-39-42-44

840 (950)

840 (950)

298 (35)

27

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP125BA2

14.0 (5.0-16.0)

12.5 (5.5-14.0)

11.9 (4.25-13.6)

11.25 (4.95-12.6)

0.81

3.99/3.35 [3.92/3.30]

A / A

22-25-28-31

15.88 (5/8”)

9.52 (3/8”)

34-36-39-41

840 (950)

840 (950)

298 (35)

27

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP100BA2

11.2 (4.5-14.0)

10.0 (4.9-11.4)

9.5 (3.85-11.9)

9.0 (4.4-10.25)

0.79

4.41/4.10 [4.31/4.00]

A / A

20-23-26-30

15.88 (5/8”)

9.52 (3/8”)

32-34-37-40

840 (950)

840 (950)

298 (35)

27

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP71BA2

8.0 (3.5-10.2)

7.1 (3.3-8.1)

6.8 (3.0-8.65)

6.4 (2.95-7.3)

0.81

4.21 / 3.66

A / A

14-16-18-21

15.88 (5/8”)

9.52 (3/8”)

28-30-32-34

840 (950)

840 (950)

258 (35)

23

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP60BA

7.0 (2.8-8.2)

6.0 (2.7-6.7)

5.95 (2.4-6.95)

5.4 (2.45-6.05)

0.76

3.78 / 3.64

A / A

12-14-16-18

15.88 (5/8”)

9.52 (3/8”)

28-29-31-32

840 (950)

840 (950)

258 (35)

23

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP50BA

6.0 (2.5-7.3)

5.0 (2.3-5.6)

5.1 (2.15-6.2)

4.5 (2.05-5.05)

0.81

3.61 / 3.23

A / A

12-14-16-18

12.7 (1/2”)

6.35 (1/4”)

28-29-31-32

840 (950)

840 (950)

258 (35)

22

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP35BA

4.1 (1.6-5.2)

3.6 (1.6-4.5)

3.5 (1.35-4.4)

3.25 (1.45-4.05)

0.84

3.66 / 3.36

A / A

11-12-13-15

12.7 (1/2”)

6.35 (1/4”)

27-28-29-31

840 (950)

840 (950)

258 (35)

22

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PUHZ-RP35VHA3

46 / 44

42

800

300 + 23

600

220-240v, 50Hz

Single

1.12 / 1.07

1.00 / 0.91

5

4.37 / 4.23 [13]

-

16

3

50

30

2.5

PUHZ-RP50VHA3

46 / 44

42

800

300 + 23

600

220-240v, 50Hz

Single

1.66 / 1.55

1.48 / 1.32

5

6.76 / 6.52 [13]

-

16

3

50

30

2.5

PUHZ-RP60VHA3

48 / 47

68

950

330 + 30

943

220-240v, 50Hz

Single

1.85 / 1.65

1.65 / 1.40

5

7.79 / 6.97 [19]

-

25

3

50

30

3.5

PUHZ-RP71VHA3

48 / 47

68

950

330 + 30

943

220-240v, 50Hz

Single

1.90 / 1.94

1.69 / 1.65

5

10.17 / 8.55 [19]

-

25

3

50

30

3.5

PUHZ-RP100VHA3/YHA3

51 / 49

116 / 130

950

330 + 30

1350

220-240v, 50Hz / 380-415,50Hz

Single / 3

2.54/2.44 [2.60/2.50]

2.26/2.07 [2.31/2.13]

5

13.26 / 13.47 [28]

4.90 / 5.02 [13]

32 / 16

3 / 5

75

30

5.0

PUHZ-RP125VHA2/YHA2

52 / 50

116 / 130

950

330 + 30

1350

220-240v, 50Hz / 380-415,50Hz

Single / 3

3.51/3.73[3.57/3.79]

3.12/3.17 [3.18/3.22]

5

16.92 / 16.53 [28]

6.14 / 6.04 [13]

32 / 16

3 / 5

75

30

5.0

PUHZ-RP140VHA2/YHA2

52 / 50

116 / 130

950

330 + 30

1350

220-240v, 50Hz / 380-415,50Hz

Single / 3

4.43 / 4.65

3.94 / 3.95

5

20.92 / 20.72 [29.5]

7.37 / 7.53 [13]

40 / 16

3 / 5

75

30

5.0

PUHZ-RP - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

[3 Phase] Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

4-Way Blow Ceiling Cassette System

PLA-RP Power Inverter Heat Pump

Technical Information

Page 84

Page 86: 2008 Product Catalogue

INDOOR UNIT PLA-RP35-140BA(2)

Models A B

Size 35-71 241 258

Size 100-140 281 298

Upper View >

Lower View >

Side View >

Mr

Slim

Ran

ge 2

008

PLA

-RP

Pow

er In

vert

er H

eat

Pum

p

Dimensions

Page 85

Page 87: 2008 Product Catalogue

SUZ-KA35VA

48 / 47

37

800

285

550

220-240v, 50Hz

Single

1.11 / 1.09

1.01 / 0.87

4.75

4.89 / 4.77 [9.18]

16

3

20

12

1.05

SUZ-KA50VA

53-55 / 51-53

53

840

330

850

220-240v, 50Hz

Single

1.82 / 1.78

1.62 / 1.42

6.75

6.64 / 7.11 [16]

25

3

30

30

1.6

SUZ-KA60VA

53-55 / 51-53

53

840

330

850

220-240v, 50Hz

Single

2.11 / 1.94

1.92 / 1.55

9.75

10.04 / 8.71 [16]

25

3

30

30

1.8

SUZ-KA71VA

53-55 / 51-53

58

840

330

850

220-240v, 50Hz

Single

2.49 / 2.53

2.27 / 2.02

10.3

10.33 / 10.81 [16]

25

3

30

30

2.0

PUHZ-P100VHA2

54 / 50

75

950

330 + 30

943

220-240v, 50Hz

Single

3.28 / 3.12

2.92 / 2.65

4

13.49 / 13.20 [28]

32

3

50

30

2.7

PUHZ-P125VHA2

55 / 51

99

950

330 + 30

1350

220-240v, 50Hz

Single

4.11 / 4.09

3.66 / 3.48

14

17.68 / 18.37 [28]

32

3

50

30

4.5

PUHZ-P140VHA2

56 / 52

99

950

330 + 30

1350

220-240v, 50Hz

Single

4.98 / 5.21

4.43 / 4.43

14

22.31 / 23.55 [29.5]

40

3

50

30

4.5

SUZ-KA / PUHZ-P - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) (Lo-Hi) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg)

Notes: All units charged to 7m (35-71), 20m (100) and 30m (125-140) pipe length.

PLA-RP - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi1-Mi2-Hi

DIMENSIONS (mm) Width

(Grille) Depth

Height

WEIGHT (kg) Unit

Panel

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

GRILLE REFERENCE

WIRED REMOTE CONTROLLER REFERENCE

PLA-RP140BA

16.0 (5.0-18.0)

13.6 (5.5-15.0)

13.6 (4.25-15.3)

12.25 (4.95-13.5)

0.71

3.21 / 2.61

C / D

24-26-29-32

15.88 (5/8”)

9.52 (3/8”)

36-39-42-44

840 (950)

840 (950)

298 (35)

27

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP125BA

14.0 (5.0-16.0)

12.3 (5.5-14.0)

11.9 (4.25-13.6)

11.05 (4.95-12.6)

0.71

3.41 / 3.01

B / B

22-25-28-31

15.88 (5/8”)

9.52 (3/8”)

34-36-39-41

840 (950)

840 (950)

298 (35)

25

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP100BA

11.2 (4.5-12.5)

9.4 (4.9-11.2)

9.5 (3.85-10.65)

8.45 (4.4-10.1)

0.74

3.41 / 3.01

B / B

20-23-26-30

15.88 (5/8”)

9.52 (3/8”)

32-34-37-40

840 (950)

840 (950)

298 (35)

25

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP71BA

8.0 (0.9-10.2)

7.1 (0.9-8.1)

6.65 (0.75-8.5)

7.05 (0.9-8.05)

0.73

3.21 / 2.81

C / C

14-16-18-21

15.88 (5/8”)

9.52 (3/8”)

28-30-32-34

840 (950)

840 (950)

258 (35)

23

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP60BA

6.9 (0.9-8.0)

5.7 (1.1-6.3)

5.75 (0.75-6.65)

5.65 (1.1-6.25)

0.76

3.27 / 2.94

C / C

12-14-16-18

15.88 (5/8”)

6.35 (1/4”)

28-29-31-32

840 (950)

840 (950)

258 (35)

23

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP50BA

6.0 (0.9-7.2)

5.0 (1.1-5.6)

5.0 (0.75-6.0)

4.95 (1.1-5.55)

0.81

3.30 / 2.81

C / C

12-14-16-18

12.7 (1/2”)

6.35 (1/4”)

28-29-31-32

840 (950)

840 (950)

258 (35)

22

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP35BA

4.1 (0.9-5.0)

3.5 (1.0-3.9)

3.4 (0.75-4.15)

3.45 (1.0-3.85)

0.84

3.69 / 3.21

A / A

11-12-13-15

9.52 (3/8”)

6.35 (1/4”)

27-28-29-31

840 (950)

840 (950)

258 (35)

22

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

4-Way Blow Ceiling Cassette System

PLA-RP Standard Inverter Heat Pump

The new Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the more expensive Power Inverter range.

� Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed

� Reduced draft air distribution, with independent vane control

� Filter lowering operation down to 4m(optional PLP-6BAJ grille required)

� Optional ‘I See Sensor’ for energy saving andsmooth temperature control throughout the room

Technical Information

Page 86

Page 88: 2008 Product Catalogue

INDOOR UNIT PLA-RP35-140BA

Models A B

Size 35-71 241 258

Size 100-140 281 298

Upper View >

Lower View >

Side View >

Mr

Slim

Ran

ge 2

008

PLA

-RP

Stan

dard

Inve

rter

Hea

t Pu

mp

Dimensions

Page 87

Page 89: 2008 Product Catalogue

PLA-RP - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi1-Mi2-Hi

DIMENSIONS (mm) (grille) Width

Depth

Height

WEIGHT (kg) Unit

Panel

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

GRILLE REFERENCE

WIRED REMOTE CONTROLLER REFERENCE

PLA-RP100BA

11.5

10.0

9.8

9.0

0.74

20-23-26-30

15.88 (5/8”)

9.52 (3/8”)

32-34-37-40

840 (950)

840 (950)

298 (35)

25

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP125BA

14.3

12.3

12.15

11.05

0.71

22-25-28-31

15.88 (5/8”)

9.52 (3/8”)

34-36-39-41

840 (950)

840 (950)

298 (35)

25

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP140BA

17.0

14.2

14.45

12.8

0.71

24-26-29-32

15.88 (5/8”)

9.52 (3/8”)

36-39-42-44

840 (950)

840 (950)

298 (35)

27

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

4-Way Blow Ceiling Cassette System

PLA-RP Heat Pump

PUH-P100YHA

52 / 50

94

950

330 + 30

943

380-415,50Hz

3

3.40 / 3.53

3.03 / 3.00

45

6.05 / 6.33 [12.2]

20

5

50

50

4.4

PUH-P125YHA

52 / 50

131

950

330 + 30

1350

380-415v, 50Hz

3

4.23 / 4.36

3.76 / 3.71

70

7.51 / 7.79 [16.1]

20

5

50

50

5.0

PUH-P140YHA

53 / 51

131

950

330 + 30

1350

380-415v, 50Hz

3

5.35 / 5.41

4.76 / 4.60

85

9.45 / 9.62 [19.8]

25

5

50

50

5.0

PUH-P - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

Notes: Optional infra-red grille and remote controller available.

Technical Information

� Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed

� Reduced draft air distribution, with independent vane control

� Filter lowering operation down to 4m (optional PLP-6BAJ grille required)

� Optional ‘I See Sensor' for energy saving and smooth temperature control throughout the room

The Heat Pump system provides a low cost alternative to three phase Power Inverter systems.

Page 88

Page 90: 2008 Product Catalogue

INDOOR UNIT PLA-RP100-140BA

Models A B

Size 35-71 241 258

Size 100-140 281 298

Upper View >

Lower View >

Side View >

Mr

Slim

Ran

ge 2

008

PLA

-RP

Hea

t Pu

mp

Dimensions

Page 89

Page 91: 2008 Product Catalogue

PCA-RP - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi1-Mi2-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PCA-RP140GA

16.0 (5.0-18.0)

14.0 (5.5-15.3)

13.6 (4.25-15.3)

12.6 (4.95-13.75)

0.75

3.48 / 3.01

B / B

27-30-32-34

15.88 (5/8”)

9.52 (3/8”)

42-44-46-48

1620

680

270

45

Fed by Outdoor Unit

Single

6

4

PCA-RP125GA

14.0 (5.0-16.0)

12.5 (5.5-14.0)

11.9 (4.25-13.6)

11.25 (4.95-12.6)

0.77

3.41 / 3.22

B / A

27-30-32-34

15.88 (5/8”)

9.52 (3/8”)

41-43-45-46

1620

680

270

43

Fed by Outdoor Unit

Single

6

4

PCA-RP100GA

11.2 (4.5-14.0)

10.0 (4.9-11.4)

9.5 (3.85-11.9)

9.0 (4.4-10.25)

0.75

3.44 / 3.42

B / A

20-21-23-25

15.88 (5/8”)

9.52 (3/8”)

40-41-43-45

1310

680

270

37

Fed by Outdoor Unit

Single

6

4

PCA-RP71GA

7.6 (3.5-10.2)

7.1 (3.3-8.1)

6.45 (3.0-8.65)

6.4 (2.95-7.3)

0.74

3.41 / 3.32

B / A

14-15-16-18

15.88 (5/8”)

9.52 (3/8”)

37-39-41-43

1310

680

210

34

Fed by Outdoor Unit

Single

6

4

PCA-RP60GA

7.0 (2.8-8.2)

6.0 (2.7-6.7)

5.95 (2.4-6.95)

5.4 (2.45-6.05)

0.86

3.45 / 3.68

B / A

14-15-16-18

15.88 (5/8”)

9.52 (3/8”)

37-39-41-43

1310

680

210

34

Fed by Outdoor Unit

Single

6

4

PCA-RP50GA2

6.0 (2.5-7.3)

5.0 (2.3-5.6)

5.1 (2.15-6.2)

4.5 (2.05-5.05)

0.88

3.41 / 3.01

B / B

14-15-16-18

12.7 (1/2”)

6.35 (1/4”)

37-39-41-43

1310

680

210

34

Fed by Outdoor Unit

Single

6

4

Ceiling Suspended System

PCA-RP Power Inverter Heat Pump

� Indoor unit designed for direct ceiling suspension

� Flush to wall installation for concealmentof service connections

� Electronic control includes learning defrost, fault finding diagnostics, low ambient fan speed control and anti-phase/ single phase protection

PUHZ-RP50VHA3

46 / 44

42

800

300 + 23

600

220-240v, 50Hz

Single

1.76 / 1.66

1.57 / 1.41

5

7.0 / 6.69 [13]

-

16

3

50

30

2.5

PUHZ-RP60VHA3

48 / 47

68

950

330 + 30

943

220-240v, 50Hz

Single

2.03 / 1.63

1.81 / 1.39

5

8.03 / 7.14 [19]

-

25

3

50

30

3.5

PUHZ-RP71VHA3

48 / 47

68

950

330 + 30

943

220-240v, 50Hz

Single

2.23 / 2.14

1.98 / 1.82

5

10.27 / 8.57 [19]

-

25

3

50

30

3.5

PUHZ-RP100VHA3/YHA3

51 / 49

116 / 130

950

330 + 30

1350

220-240v, 50Hz / 380-415,50Hz

Single / 3

3.26 / 2.92

2.90 / 2.48

5

13.08 / 13.22 [28]

4.72 / 4.77 [13]

32 / 16

3 / 5

75

30

5.0

PUHZ-RP125VHA2/YHA2

52 / 50

116 / 130

950

330 + 30

1350

220-240v, 50Hz / 380-415,50Hz

Single / 3

4.11 / 3.88

3.66 / 3.30

5

16.99 / 16.54 [28]

6.21 / 6.05 [13]

32 / 16

3 / 5

75

30

5.0

PUHZ-RP140VHA2/YHA2

52 / 50

116 / 130

950

330 + 30

1350

220-240v, 50Hz / 380-415,50Hz

Single / 3

4.60 / 4.65

4.09 / 3.95

5

20.93 / 20.66 [29.5]

7.47 / 7.38 [13]

40 / 16

3 / 5

75

30

5.0

PUHZ-RP - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

Technical Information

Page 90

Page 92: 2008 Product Catalogue

INDOOR UNIT PCA-RP50-71GA(2)

INDOOR UNIT PCA-RP100GA

INDOOR UNIT PCA-RP125-140GA

Side View >Front View >Lower View >

Side View >Front View >Lower View >

Side View >Front View >Lower View >

Mr

Slim

Ran

ge 2

008

PCA

-RP

Pow

er In

vert

er H

eat

Pum

p

Dimensions

Page 91

Page 93: 2008 Product Catalogue

SUZ-KA50VA

53-55 / 51-53

53

840

330

850

220-240v, 50Hz

Single

1.76 / 1.78

1.60 / 1.42

6.75

6.88 / 7.28 [16]

25

3

30

30

1.6

SUZ-KA60VA

53-55 / 51-53

53

840

330

850

220-240v, 50Hz

Single

2.05 / 1.92

1.87 / 1.54

9.75

10.28 / 8.88 [16]

25

3

30

30

1.8

SUZ-KA71VA

53-55 / 51-53

58

840

330

850

220-240v, 50Hz

Single

2.49 / 2.53

2.27 / 2.02

10.3

10.43 / 10.83 [16]

25

3

30

30

2.0

PUHZ-P100VHA2

54 / 50

75

950

330 + 30

943

220-240v, 50Hz

Single

3.49 / 3.35

3.11 / 2.85

4

13.31 / 12.95 [28]

32

3

50

30

2.7

PUHZ-P125VHA2

55 / 51

99

950

330 + 30

1350

220-240v, 50Hz

Single

4.98 / 4.38

4.43 / 3.72

14

17.75 / 18.38 [28]

32

3

50

30

4.5

PUHZ-P140VHA2

56 / 52

99

950

330 + 30

1350

220-240v, 50Hz

Single

4.98 / 5.21

4.43 / 4.43

14

22.32 / 23.49 [29.5]

40

3

50

30

4.5

SUZ-KA / PUHZ-P - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) (Lo-Hi) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg)

Notes: All units charged to 7m (50-71), 20m (100) and 30m (125-140) pipe length.

PCA-RP - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi1-Mi2-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PCA-RP140GA

16.0 (5.0-18.0)

13.6 (5.5-15.0)

13.6 (4.25-15.3)

12.25 (4.95-13.5)

0.76

3.21 / 2.61

C / D

27-30-32-34

15.88 (5/8”)

9.52 (3/8”)

42-44-46-48

1620

680

270

45

Fed by Outdoor Unit

Single

6

4

PCA-RP125GA

14.0 (5.0-16.0)

12.3 (5.5-14.0)

11.9 (4.25-13.6)

11.05 (4.95-12.6)

0.78

2.81 / 2.81

D / C

27-30-32-34

15.88 (5/8”)

9.52 (3/8”)

41-43-45-46

1620

680

270

43

Fed by Outdoor Unit

Single

6

4

PCA-RP100GA

11.2 (4.5-12.5)

9.4 (4.9-11.2)

9.5 (3.85-10.65)

8.45 (4.4-10.1)

0.77

3.21 / 2.81

C / C

20-21-23-25

15.88 (5/8”)

9.52 (3/8”)

40-41-43-45

1310

680

270

37

Fed by Outdoor Unit

Single

6

4

PCA-RP71GA

8.0 (0.9-10.2)

7.1 (0.9-8.1)

6.65 (0.75-8.5)

7.05 (0.9-8.05)

0.71

3.21 / 2.81

C / C

14-15-16-18

15.88 (5/8”)

9.52 (3/8”)

37-39-41-43

1310

680

210

34

Fed by Outdoor Unit

Single

6

4

PCA-RP60GA

6.9 (0.9-8.0)

5.5 (1.1-6.3)

5.75 (0.75-6.65)

5.45 (1.1-6.25)

0.79

3.37 / 2.86

C / C

14-15-16-18

15.88 (5/8”)

6.35 (1/4”)

37-39-41-43

1310

680

210

34

Fed by Outdoor Unit

Single

6

4

PCA-RP50GA2

6.0 (0.9-7.2)

5.0 (1.1-5.6)

5.0 (0.75-6.0)

4.95 (1.1-5.55)

0.81

3.41 / 2.81

B / C

14-15-16-18

12.7 (1/2”)

6.35 (1/4”)

37-39-41-43

1310

680

210

34

Fed by Outdoor Unit

Single

6

4

Ceiling Suspended System

PCA-RP Standard Inverter Heat Pump

The new Standard Inverter range provides inverter solutions for customers who want all the benefits thatinverters offer, but do not have the budget available for the more expensive Power Inverter range.

Technical Information

� Indoor unit designed for direct ceiling suspension

� Flush to wall installation for concealmentof service connections

� Electronic control includes learning defrost, fault finding diagnostics, low ambient fan speed control and anti-phase / single phase protection

Page 92

Page 94: 2008 Product Catalogue

INDOOR UNIT PCA-RP50-71GA(2)

INDOOR UNIT PCA-RP100GA

INDOOR UNIT PCA-RP125-140GA

Side View >Front View >Lower View >

Side View >Front View >Lower View >

Side View >Front View >Lower View >

Mr

Slim

Ran

ge 2

008

PCA

-RP

Stan

dard

Inve

rter

Hea

t Pu

mp

Dimensions

Page 93

Page 95: 2008 Product Catalogue

PCA-RP - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi1-Mi2-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PCA-RP100GA

11.5

9.8

9.8

8.8

0.75

20-21-23-25

15.88 (5/8”)

9.52 (3/8”)

40-41-43-45

1310

680

270

37

Fed by Outdoor Unit

Single

6

4

PCA-RP125GA

14.3

12.3

12.15

11.05

0.77

27-30-32-34

15.88 (5/8”)

9.52 (3/8”)

41-43-45-46

1620

680

270

43

Fed by Outdoor Unit

Single

6

4

PCA-RP140GA

17.0

14.2

14.45

12.8

0.75

27-30-32-34

15.88 (5/8”)

9.52 (3/8”)

42-44-46-48

1620

680

270

45

Fed by Outdoor Unit

Single

6

4

Ceiling Suspended System

PCA-RP Heat Pump

PUH-P - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

PUH-P100YHA

52 / 50

94

950

330 + 30

943

380-415v, 50Hz

3

3.45 / 3.55

3.07 / 3.02

45

5.87 / 6.08 [12.0]

20

5

50

50

4.4

PUH-P125YHA

52 / 50

131

950

330 + 30

1350

380-415v, 50Hz

3

4.72 / 4.52

4.20 / 3.84

70

7.58 / 7.8 [16.2]

20

5

50

50

5.0

PUH-P140YHA

53 / 51

131

950

330 + 30

1350

380-415v, 50Hz

3

5.22 / 5.44

4.65 / 4.62

85

9.46 / 9.56 [19.8]

25

5

50

50

5.0

Technical Information

� Indoor unit designed for direct ceiling suspension

� Flush to wall installation for concealment of service connections

� Electronic control includes learning defrost, fault finding diagnostics, low ambient fan speed control and anti-phase / single phase protection

The Heat Pump system provides a low cost alternative to three phase Power Inverter systems.

Page 94

Page 96: 2008 Product Catalogue

INDOOR UNIT PCA-RP100GA

INDOOR UNIT PCA-RP125-140GA

Side View >Front View >

Lower View >

Side View >Front View >

Lower View >

Mr

Slim

Ran

ge 2

008

PCA

-RP

Hea

t Pu

mp

Dimensions

Page 95

Page 97: 2008 Product Catalogue

PCA-RP71HA

7.6 (3.5-10.2)

7.1 (3.3-8.1)

6.45 (3.0-8.65)

6.4 (2.95-7.3)

0.74

3.41 / 3.21

B / A

17-19

15.88 (5/8”)

9.52 (3/8”)

34-38

1136

650

280

41

Fed by Outdoor Unit

Single

6

4

PCA-RP125HA

13.8 (5.0-16.0)

12.5 (5.5-14.0)

11.75 (4.25-13.6)

11.25 (4.95-12.6)

0.77

3.41 / 3.22

B / A

30-38

15.88 (5/8”)

9.52 (3/8”)

44-50

1520

650

280

56

Fed by Outdoor Unit

Single

6

4

PCA-RP-HA - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

Stainless Steel Ceiling Suspended System

PCA-RP-HA Power Inverter Heat Pump

PUHZ-RP71VHA3

48 / 47

68

950

330 + 30

943

220-240v, 50Hz

Single

2.23 / 2.21

1.98 / 1.88

5

10.17 / 8.47 [19]

-

25

3

50

30

3.5

PUHZ-RP125VHA2/YHA2

52 / 50

116 / 130

950

330 + 30

1350

220-240v, 50Hz / 380-415v, 50Hz

Single / 3

4.05 / 3.88

3.60 / 3.30

5

17.17 / 16.72 [28]

6.39 / 6.23 [13]

32 / 16

3 / 5

75

30

5.0

PUHZ-RP - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (KW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

The PCA-RP-HA series is a ceiling suspended unit ideal for use in kitchen environments. The external casing is made of durable stainless steel that is resistant to oil and smoke, ensuring that the unit can be easily cleaned at all times.

� High performance oil mist filter

� Easy maintenance - fan casing can be separated into different sections allowing easy cleaning. The drain pan can also be cleaned easily on-site as the pipe connector can be quickly removed

� Optional decoration covers

Technical Information

Page 96

Page 98: 2008 Product Catalogue

INDOOR UNIT PCA-RP71HA

INDOOR UNIT PCA-RP125HA

Front View >

Side View >

Lower View >

12241180

9861136

110

102

75

1136

650

258

650

280

1608

13701520

110

102

75

1564

1520

650

258

650

280

Side View >

Front View >

Lower View >

Mr

Slim

Ran

ge 2

008

PCA

-RP-

HA

Pow

er In

vert

er H

eat

Pum

p

Dimensions

Page 97

Page 99: 2008 Product Catalogue

PCA-RP125HA

13.8 (5.0-16.0)

12.3 (5.5-14.0)

11.75 (4.25-13.6)

11.05 (4.95-12.6)

0.78

3.21 / 2.81

C / C

30-38

15.88 (5/8”)

9.52 (3/8”)

44-50

1520

650

280

56

Fed by Outdoor Unit

Single

6

4

PCA-RP-HA - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

Stainless Steel Ceiling Suspended System

PCA-RP-HA Standard Inverter Heat Pump

PUHZ-P125VHA2

55 / 51

99

950

330 + 30

1350

220-240v, 50Hz

Single

4.30 / 4.38

3.83 / 3.72

14

17.93 / 18.56 [28]

32

3

50

30

4.5

PUHZ-P - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (KW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

The new Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the more expensive Power Inverter range.

� High performance oil mist filter

� Easy maintenance - fan casing can be separated into different sections allowing easy cleaning. The drain pan can also be cleaned easily on-site as the pipe connector can be quickly removed

� Optional decoration covers

Technical Information

Page 98

Page 100: 2008 Product Catalogue

INDOOR UNIT PCA-RP125HA

1608

13701520

110

102

75

1564

1520

650

258

650

280

Side View >

Front View >

Lower View >

Mr

Slim

Ran

ge 2

008

PCA

-RP-

HA

Stan

dard

Inve

rter

Hea

t Pu

mp

Dimensions

Page 99

Page 101: 2008 Product Catalogue

PCA-RP125HA

14.3

12.3

12.2

11.05

0.77

30-38

15.88 (5/8”)

9.52 (3/8”)

44-50

1520

650

280

56

Fed by Outdoor Unit

Single

6

4

PCA-RP-HA - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

Stainless Steel Ceiling Suspended System

PCA-RP-HA Heat Pump

PUH-P125YHA

52 / 50

131

950

330 + 30

1350

380-415v, 50Hz

3

5.01 / 4.55

4.46 / 3.87

70

7.76 / 7.98 [16.3]

20

5

50

50

5.0

PUH-P - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (KW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

The PCA-RP-HA series is a ceiling suspended unit ideal for use in kitchen environments. The external casing is made of durable stainless steel that is resistant to oil and smoke, ensuring that the unit can be easily cleaned at all times.

� High performance oil mist filter

� Easy maintenance - fan casing can be separated into different sections allowing easy cleaning. The drain pan can also be cleaned easily on-site as the pipe connector can be quickly removed

� Optional decoration covers

Technical Information

The Heat Pump system provides a low cost alternative to three phase Power Inverter systems.

Page 100

Page 102: 2008 Product Catalogue

INDOOR UNIT PCA-RP125HA

1608

13701520

110

102

75

1564

1520

650

258

650

280

Side View >

Front View >

Lower View > Mr

Slim

Ran

ge 2

008

PCA

-RP-

HA

Hea

t Pu

mp

Dimensions

Page 101

Page 103: 2008 Product Catalogue

PSA-RP71GA

7.6 (3.5-10.2)

7.1 (3.3-8.1)

6.45 (3.0-8.65)

6.4 (2.95-7.3)

0.73

3.41 / 3.23

B / A

15-18

15.88 (5/8”)

9.52 (3/8”)

40-45

600

270

1900

43

Fed by Outdoor Unit

Single

6

4

PSA-RP125GA

14.0 (5.0-16.0)

12.4 (5.5-14.0)

11.9 (4.25-13.6)

11.15 (4.95-12.6)

0.75

3.41 / 3.01

B / B

26-33

15.88 (5/8”)

9.52 (3/8”)

46-51

600

350

1900

51

Fed by Outdoor Unit

Single

6

4

PSA-RP - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

Floor Standing System

PSA-RP Power Inverter Heat Pump

PUHZ-RP71VHA3

48 / 47

68

950

330 + 30

943

220-240v, 50Hz

Single

2.23 / 2.20

1.98 / 1.87

5

10.4 / 8.7 [19]

-

25

3

50

30

3.5

PUHZ-RP125VHA2/YHA2

52 / 50

116 / 130

950

330 + 30

1350

220-240v, 50Hz / 380-415v, 50Hz

Single / 3

4.11 / 4.12

3.66 / 3.50

5

17.21 / 16.76 [28]

6.43 / 6.27 [13]

32 / 16

3 / 5

75

30

5.0

PUHZ-RP - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (KW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

Technical InformationNote: When used with a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.

The PSA-RP Floor Standing System compliments the MitsubishiElectric range of indoor units. The sleek, modern design of this unitis ideal for numerous applications including bars and restaurants.

� Built in controller

Page 102

Page 104: 2008 Product Catalogue

INDOOR UNIT PSA-RP71GA

INDOOR UNIT PSA-RP125GA

Front View > Side View > Upper View >

Front View > Side View > Upper View >

Mr

Slim

Ran

ge 2

008

PSA

-RP

Pow

er In

vert

er H

eat

Pum

p

Dimensions

Page 103

Page 105: 2008 Product Catalogue

PSA-RP125GA

14.0 (5.0-16.0)

12.3 (5.5-14.0)

11.9 (4.25-13.6)

11.05 (4.95-12.6)

0.76

2.81 / 2.81

D / C

26-33

15.88 (5/8”)

9.52 (3/8”)

46-51

600

350

1900

51

Fed by Outdoor Unit

Single

6

4

PSA-RP - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PSA-RP Standard Inverter Heat Pump

PUHZ-P125VHA2

55 / 51

99

950

330 + 30

1350

220-240v, 50Hz

Single

4.98 / 4.38

4.43 / 3.72

14

17.97 / 18.6 [28]

32

3

50

30

4.5

PUHZ-P - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (KW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

Floor Standing System

Technical Information

The Standard Inverter range provides inverter solutions for customerswho want all the benefits that inverters offer, but do not have the budgetavailable for the more expensive Power Inverter range.

The PSA-RP Floor Standing System compliments the Mitsubishi Electricrange of indoor units. The sleek, modern design of this unit is ideal for numerous applications including bars and restaurants.

� Built in controller

Note: When used with a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.

Page 104

Page 106: 2008 Product Catalogue

INDOOR UNIT PSA-RP125GA

Front View > Side View > Upper View >

Mr

Slim

Ran

ge 2

008

PSA

-RP

Stan

dard

Inve

rter

Hea

t Pu

mp

Dimensions

Page 105

Page 107: 2008 Product Catalogue

PSA-RP125GA

14.3

12.3

12.2

11.05

0.75

26-33

15.88 (5/8”)

9.52 (3/8”)

46-51

600

350

1900

51

Fed by Outdoor Unit

Single

6

4

PSA-RP - INDOOR UNITSMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal)

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PSA-RP Heat Pump

PUH-P125YHA

52 / 50

131

950

330 + 30

1350

380-415v, 50Hz

3

4.41 / 4.54

3.92 / 3.86

70

7.8 / 8.02 [16.4]

20

5

50

50

5.0

PUH-P - OUTDOOR UNITSMODEL REFERENCE

NOISE (dBA) Heating/cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (KW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

Floor Standing System

Technical Information

The Heat Pump system provides a low cost alternative to three phase Power Inverter systems.

The PSA-RP Floor Standing System compliments the Mitsubishi Electric range of indoor units. The sleek, modern design of this unit is ideal for numerous applications including bars and restaurants.

� Built in controller

Note: When used with a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.

Page 106

Page 108: 2008 Product Catalogue

INDOOR UNIT PSA-RP125GA

Front View > Side View > Upper View >

Mr

Slim

Ran

ge 2

008Dimensions

PSA

-RP

Hea

t Pu

mp

Page 107

Page 109: 2008 Product Catalogue

PHV DXE Heat Pump Air CurtainHeat Pump Air Curtain System

In collaboration with Thermoscreens, Mitsubishi Electric have developed a range of air cur tains that are able tobe connected to our Power Inver ter heat pumps, as opposed to the more traditional direct electric methodassociated with air cur tains.

� Reduced CO2 emissions (up to 67%)

� Reduced Running Costs (up to 67%)

� 2.5 year payback period against equivalent Electric system

� Inverter technology (does not waste energy)

� Range of different sizes to suit every application

� Allows open door policy in retail outletswhilst being energy efficient

� Clean environment - protection from dust, fumes etc

� Comfortable climate for customers

� Easy to install and maintain

Page 108

PHV DXE - RECESSEDMODEL REFERENCE

DIMENSIONS (mm) (WxDxH)

SUPPLY (50Hz)

HEAT OUTPUT (kW) 100% / 50%

COP 100% / 50%

LOADING (amps)

VELOCITY (m/s)

AIR VOLUME (m3/h)

WEIGHT (kg)

dB(A) @ 3m 100% / 50%

MAX. MOUNTING HEIGHT (m)

OUTDOOR UNIT MODEL

PHV1500R DXE HO

1650x436x296

415V*1

14.4 / 8.3

2.5 / 3.7

12.7*1

9

2600

67

60 / 58

3.5

PUHZ-RP140VHA2/YHA2

PHV2000R DXE LO

2240x436x296

415V*2

14.1 / 7.9

2.9 / 3.7

15.7*2

9.5

3300

85

61 / 59

3.5

PUHZ-RP100VHA3/YHA3

PHV2000R DXE HO

2240x436x296

415V*2

21.3 / 11.2

2.4 / 3.2

15.7*2

9

3130

88

61 / 59

3.5

PUHZ-RP200YHA2

Technical Information

Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.

PHV DXE - FREE STANDINGMODEL REFERENCE

DIMENSIONS (mm) (WxDxH)

SUPPLY (50Hz)

HEAT OUTPUT (kW) 100% / 50%

COP 100% / 50%

LOADING (amps)

VELOCITY (m/s)

AIR VOLUME (m3/h)

WEIGHT (kg)

dB(A) @ 3m 100% / 50%

MAX. MOUNTING HEIGHT (m)

OUTDOOR UNIT MODEL

PHV1500 DXE HO

1746x377x255

415V*1

14.4 / 8.3

2.5 / 3.7

12.7*1

9

2600

60

60 / 58

3.75

PUHZ-RP140VHA2/YHA2

PHV2000 DXE LO

2296x377x255

415V*2

14.1 / 7.9

2.9 / 3.7

15.7*2

9.5

3300

78

61 / 59

3.75

PUHZ-RP100VHA3/YHA3

PHV2000 DXE HO

2296x377x255

415V*2

21.3 / 11.2

2.4 / 3.2

15.7*2

9.5

3130

80

61 / 59

3.75

PUHZ-RP200YHA2

Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.

HEAT PUMP OUTDOOR UNITSMODEL REFERENCE

DIMENSIONS (mm) (WxDxH)

SUPPLY (50Hz)

MAX. CURRENT (A)

FUSE SIZE HRC (BS88)

MAX. PIPE RUN Length (m)

Height (m)

PIPE SIZES Gas mm(in)

Liquid mm(in)

INTERCONNECTING CABLE

PUHZ-RP100VHA3/YHA3

950x330+30x1350

230V / 415V

28 / 13

32 / 16

50

30

15.88 (5/8)

9.52 (3/8)

2 core

PUHZ-RP140VHA2/YHA2

950x330+30x1350

230V / 415V

29.5 / 13

40 / 16

50

30

15.88 (5/8)

9.52 (3/8)

2 core

PUHZ-RP200YHA2

950x330+30x1350

415V

19

25

100

30

28.58 (1 1/8)

9.52 (3/8)

2 core

Page 110: 2008 Product Catalogue

AIR CURTAIN PHV1500/2000R DXE

Mr

Slim

Ran

ge 2

008Dimensions

PHV

DX

EA

ir C

urta

in

AIR CURTAIN PHV1500/2000 DXE

Rear View >

Upper View >

Side View > Rear View >

Page 109

Side View >

Upper View >

Page 111: 2008 Product Catalogue

Heat Pump

Mr Slim Multi-Split Systems

IndoorUnits

Indoor Units

Outdoor UnitsOutdoor Units

Multi distributorPipes

Multi distributorPipes

BB

C

CD

h h

HH

Indoor Units

OutdoorUnits

Multi distributorPipes

CD

E

B

A

h

H

AA

QUADRUPLETRIPLETWIN

PIPE RUN PARAMETERS

Outdoor Model Pipe Runs Max. Pipe Run (m)

PUH-P100-140YHA A+B+C twin 50

PUH-P100-140YHA A+B+C+D triple 50

PUH-P100-140YHA B – C or C – D or B – D 8

PUHZ-P100-140VHA2 A+B+C twin 50

PUHZ-P200/250YHA A+B+C twin 70

PUHZ-RP71VHA3 A+B+C twin 50

PUHZ-RP100-140V/YHA2/3 A+B+C twin 75

PUHZ-RP200/250YHA2 A+B+C twin 80 (120)

PUHZ-P140VHA2 A+B+C+D triple 50

PUHZ-P200/250YHA A+B+C+D triple 70

PUHZ-RP140V/YHA2 A+B+C+D triple 75

PUHZ-RP200/250YHA2 A+B+C+D triple 80 (120)

PUHZ-P200/250YHA A+B+C+D+E quadruple 70

PUHZ-RP200/250YHA2 A+B+C+D+E quadruple 80 (120)

PUHZ-P100-140VHA2 B – C or C – D or B – D 8

PUHZ-RP71-140V/YHA2/3 B – C or C – D or B – D 8

PUHZ-P200/250YHA B - C or B - D or B - E or C - D or C - E or D - E 8

PUHZ-RP200/250YHA2 B - C or B - D or B - E or C - D or C - E or D - E 8

H = 30m. h = 1m. Note: H for the PUHZ-RP200/250YHA2 = 40m

The multi-split system is an ideal option for open plan spaces in medium sized premises such as offices or shops, where two,three or four units are required. These can be Mr Slim ceiling cassettes (PLA-RP), ceiling suspended (PCA-RP), ducted (PEAD-RP), floor standing (PSA-RP) or wall mounted (PKA-RP) models and can be connected to a single outdoor unit usingtwin, triple or quadruple multi distributor pipes.

� Twin, triple or quadruple indoor heat pump units can be operated inMulti-Split configuration from a single outdoor unit

� Heat pumps must operate in same heating or cooling mode

� Cooling capacity range 3.3 to 28kW

� Heating capacity range 3.5 to 31.5kW

Note: SEZ or SLZ units cannot be used as part of a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type. Technical Information

≥≥

Page 110

h

Page 112: 2008 Product Catalogue

Outdoor Heat Pump

PUHZ-RP71

PUH-P100

PUHZ-P100

PUHZ-RP100

PUH-P125

PUHZ-P125

PUHZ-RP125

PUH-P140

PUHZ-P140

PUHZ-RP140

PUH-P140

PUHZ-P140

PUHZ-RP140

PUHZ-P200

PUHZ-P200

PUHZ-P200

PUHZ-RP200

PUHZ-RP200

PUHZ-RP200

PUHZ-P250

PUHZ-P250

PUHZ-P250

PUHZ-RP250

PUHZ-RP250

PUHZ-RP250

Total Heating Capacity (kW)

3.5 - 10.2

11.5

4.5 - 12.5

4.5 - 14.0

14.3

5.0 - 16.0

5.0 - 16.0

17.0

5.0 - 18.0

5.0 - 18.0

17.0

5.0 - 18.0

5.0 - 18.0

9.5 - 25.0

9.5 - 25.0

9.5 - 25.0

9.5 - 25.0

9.5 - 25.0

9.5 - 25.0

12.5 - 31.5

12.5 - 31.5

12.5 - 31.5

12.5 - 31.5

12.5 - 31.5

12.5 - 31.5

Total Cooling Capacity (kW)

3.3 - 8.1

10.0

4.9 - 11.2

4.9 - 11.4

12.3

5.5 - 14.0

5.5 - 14.0

14.2

5.5 - 15.0

5.5 - 15.3

14.2

5.5 - 15.0

5.5 - 15.3

9.0 - 22.4

9.0 - 22.4

9.0 - 22.4

9.0 - 22.4

9.0 - 22.4

9.0 - 22.4

11.2 - 28.0

11.2 - 28.0

11.2 - 28.0

11.2 - 28.0

11.2 - 28.0

11.2 - 28.0

Pipe Kit Part Number

MSDD-50SR-E

MSDD-50SR-E

MSDD-50SR-E

MSDD-50SR-E

MSDD-50SR-E

MSDD-50SR-E

MSDD-50SR-E

MSDD-50SR-E

MSDD-50SR-E

MSDD-50SR-E

MSDT-111R-E

MSDT-111R-E

MSDT-111R-E

MSDD-50WR-E

MSDT-111R-E

MSDF-1111R-E

MSDD-50WR-E

MSDT-111R-E

MSDF-1111R-E

MSDD-50WR-E

MSDT-111R-E

MSDF-1111R-E

MSDD-50WR-E

MSDT-111R-E

MSDF-1111R-E

Multi-Split Systems - Combinations Table

Indoor Unit

Size 35

Size 50

Size 50

Size 50

Size 60

Size 60

Size 60

Size 71

Size 71

Size 71

Size 50

Size 50

Size 50

Size 100

Size 60

Size 50

Size 100

Size 60

Size 50

Size 125

Size 71

Size 60

Size 125

Size 71

Size 60

No. of Indoor Units

2

2

2

2

2

2

2

2

2

2

3

3

3

2

3

4

2

3

4

2

3

4

2

3

4

Technical Information

Mul

ti-Sp

lit S

yste

ms

Mr

Slim

Ran

ge 2

008

Page 111

Page 113: 2008 Product Catalogue

Outdoor Units

SUZ-KA50/60/71VA

Side View >

SUZ-KA25/35VA

Upper View >

Front View >

Upper View >

Front View > Side View >

Dimensions

Page 112

Page 114: 2008 Product Catalogue

Upper View >

Left Side View > Front View > Right Side View >Rear View >

PUHZ-RP35/50VHA3

Front View >

Upper View >

PUHZ-RP60/71VHA3 / PUHZ-P100VHA2 / PUH-P100YHA

Right Side View >

Dimensions

Out

door

Uni

t D

imen

sion

sM

r Sl

imR

ange

200

8

Page 113

Page 115: 2008 Product Catalogue

Upper View >

Left Side View > Front View > Right Side View >Rear View >

Outdoor UnitsPUHZ-RP100VHA3/YHA3 / PUHZ-RP125-250VHA2 / PUHZ-P125/140VHA2PUHZ-P200/250YHA / PUH-P125/140YHA

Dimensions

Page 114

Page 116: 2008 Product Catalogue

Out

door

Uni

t D

imen

sion

s /

Air

Han

dlin

g U

nit

Con

trol

ler

Mr

Slim

Ran

ge 2

008

Air Handling Unit Controller

PAC-IF011B-E

PAC-IF011B-EMITSUBISHI ELECTRIC OUTDOOOR UNIT

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

AUTO STEP PUHZ-RP

PUHZ-P

SUZ-KA

PUH-P

MANUAL STEP PUHZ-RP

PIPE SIZE (mm) PUHZ-(R)P

SUZ-KA

Gas / Liquid PUH-P

HEAT EXCHANGER Max Capacity

Min Capacity

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

SIZE 35

4.1

3.5

VHA3

-

VA

-

VHA3

12.7 / 6.35

9.52 / 6.35

-

1050

350

336

69

278

2.5

SIZE 50

6.0

5.0

VHA3

-

VA

-

VHA3

12.7 / 6.35

12.7 / 6.35

-

1500

500

336

69

278

2.5

SIZE 60

7.0

6.0

VHA3

-

VA

-

VHA3

15.88 / 9.52

15.88 / 6.35

-

1800

600

336

69

278

2.5

SIZE 71

7.6

7.1

VHA3

-

VA

-

VHA3

15.88 / 9.52

15.88 / 9.52

-

2130

710

336

69

278

2.5

SIZE 100

11.2

10.0

V/YHA3

VHA2

-

YHA

V/YHA3

15.88 / 9.52

-

15.88 / 9.52

3000

1000

336

69

278

2.5

SIZE 125

14.0

12.5

V/YHA2

VHA2

-

YHA

V/YHA2

15.88 / 9.52

-

15.88 / 9.52

3750

1250

336

69

278

2.5

SIZE 140

16.0

14.0

V/YHA2

VHA2

-

YHA

V/YHA2

15.88 / 9.52

-

15.88 / 9.52

4200

1400

336

69

278

2.5

SIZE 200

22.4

19.0

YHA2

YHA

-

-

YHA2

28.58 / 9.52

-

-

6000

2000

336

69

278

2.5

SIZE 250

27.0

22.0

YHA2

YHA

-

-

YHA2

28.58 / 12.7

-

-

7500

2500

336

69

278

2.5

The Air Handling Unit Controllers are an interface to allow connectionto third party manufacturer equipment.

Mitsubishi Electric Mr Slim outdoor units can be used with this interface box, creating an ideal solution when a unique air handling unit is required.

� No need for expansion device

� Error, operation and defrost output

� Demand control by analogue or digital inputs(0-10Ω, 4-20mA , 1-5V, 0-10V, Step, Auto-Step)

Note: One air handling unit controller is required per air handling unitCooling: Indoor 27ºC DB/19ºC WB, Outdoor 35ºC DB/24ºC WBHeating: Indoor 20ºC DB, Outdoor 7ºC DB/6ºC WB

A Control wiring Thermistor wiring

Piping

Air Handling Unit (field supplied)

Controller (field supplied)

Outdoor Unit (Mitsubishi Electric)

Air Handling Unit Controller (Mitsubishi Electric)

Example:

Technical Information

Page 115

VOLUME (cm3)

Page 117: 2008 Product Catalogue

Accessories / Optional ExtrasM Series

Wall Mounted Units S70 515 716 - Terminal blockS71 000 028 - CN22 connector

Ceiling Concealed Ducted Units PAC-SK005MT-F - 130Pa fan motor PEAD-RP71EAPAC-SK004MT-F - 130Pa fan motor PEAD-RP100EA2PAC-SK003MT-F - 130Pa fan motor PEAD-RP125/140EAPAC-KE03DM-G - Optional drain lift pump PEAD-RP35-140EA(2)MAC-399IF - Interface for connection to M-NET System SEZ-KD25-71VAMAC-397IF - Interface for group control and run/fault SEZ-KD25-71VA

4-Way Blow Cassette Units PAC-SH53TM-E - Multi function casement PLA-RP35-140BA(2) for fresh air 100mm knockout orto hold the high efficiency filter option

PAC-SH59KF-E - High efficiency filter PLA-RP35-140BA(2)PLP-6BALM - Grille and infra-red controller PLA-RP35-140BA(2)PLP-6BAJ - Grille with filter lowering function PLA-RP35-140BA(2)PAC-SA1ME-E - ‘I-See Sensor’ corner panel PLA-RP35-140BA(2)PAR-SA9FA-E - Infra-red signal receiver PLA-RP35-140BA(2)S70E40714 - Infra-red controller (PAR-SL97A-E) PLA-RP35-140BA(2)MAC-399IF - Interface for connection to M-NET System SLZ-KA25-50VAMAC-397IF - Interface for group control and run/fault SLZ-KA25-50VA

Ceiling Suspended Units PAR-SL99B-E - Wireless remote controller and adaptorPAC-SE85DMA-E - Optional drain lift pump PCA-RP50-71GA(2)PAC-SE86DMA-E - Optional drain lift pump PCA-RP100-140GAPAC-SG38KF-E - Oil mist filter for PCA-RP71/125HA (12 pack)PAC-SF81KC-E - Decoration covers (front cover & suspending bracket) for PCA-RP71HAPAC-SF82KC-E - Decoration covers (front cover & suspending bracket) for PCA-RP125HA

Outdoor Units PAC-SG61DS-E - Drain socket set PUHZ-RP35-250V/YHA2/3 / PUHZ-P100-250VHA2/YHAPAC-SG58SG-E - Air outlet guide PUHZ-RP35-50VHA3PAC-SG59SG-E - Air outlet guide PUHZ-RP60-250V/YHA2/3, 2 sets required for sizes 100-250

System Control Units PAC-SE55RA-E - Remote on/off adaptorPAC-SF40RM-E - Run/fault indicationPAC-YT32PTA-E - Program timerPAC-SE41TS-E - Remote sensorPAC-SF80MA - A/M-NET adaptorPAC-YT51CRA - Simplified remote controllerPAR-21MAA - Wired controllerPAC-SK81SI-E - Sub interface board

Pipe Kits MSDD-50SR-E - Multi distribution pipe twin units - 50:50 - sizes 71/100/125/140MSDD-50WR-E - Multi distribution pipe twin units - 50:50 - sizes 200/250MSDT-111R-E - Multi distribution pipe triple units - 33:33:33 - sizes 140/200/250MSDF-1111R-E - Multi distribution pipe quadruple units - 25:25:25:25 - sizes 200/250

Power Supply Terminal Kits PAC-SH52HR-E - Power supply terminal kit for PLA-RP when using PUHZ-RP200/250YHA2PAC-SG96HR-E - Power supply terminal kit for PKA-RP / PCA-RP / PSA-RP when using PUHZ-RP200/250YHA2PAC-SG97HR-E - Power supply terminal kit for PEAD-RP / PCA-RP-HA when using PUHZ-RP200/250YHA2

Acc

esso

ries

/ O

ptio

nal E

xtra

sM

r Sl

imR

ange

200

8

Page 116

Page 118: 2008 Product Catalogue

City MultiEnergy Efficient VRF Systems

Page 119: 2008 Product Catalogue

The City Multi rangeSolutions for more demanding applications

Efficient &

Page 118

The City Multi range is Mitsubishi Electric’s answer to large scale VRF (Variable Refrigerant Flow) applications. The efficiency of City Multiis second to none and offers a substantial increase in energy efficiency, with corresponding EER/COP ratings.

The City Multi Y Series range offers a simple and flexible solution where there is a demand for a changeover capability between heating and cooling, helping to ensure a constant, comfortable indoor climate.

Mitsubishi Electric also has the ability to provide simultaneous heating and cooling through its R2 and WR2systems. The difference here being that this is achieved through only two pipes rather than theconventional three. By using Mitsubishi Electric’s 2-pipe heat recovery technology, substantial savingscan again be made on annual running costs. With a wide range of 76 indoor units, up to 50(depending on the capacity available) can be connected to a YHM outdoor unit.

Broadening the range of potential City Multi applications is Mitsubishi Electric’s 3rd generation watercooled R410A WR2 system. This system not only produces heat recovery from the refrigerant circuitbut also via its water circuit, offering double heat recovery potential.

Sophisticated technology, combined with a high level of control and energy efficiency:

City Multi is perfectly positioned to meet the demands of today’s market.

Page 120: 2008 Product Catalogue

The Strength of City MultiThe R410A YHM-A series offers some of the highest EER/COP ratings in the market.

f lexible

Page 121: 2008 Product Catalogue

What is VRF?VRF stands for Variable Refrigerant Flow. A VRF air conditioning system modulates the flow ofrefrigerant depending upon the capacity requirements of the building. A VRF system comprises of acondensing unit sited externally and a series of multiple indoor units to provide cooling and/orheating to the occupied space.

Our answer to VRFMitsubishi Electric sets the boundaries of VRF technology with the City Multi range, which is availableusing R410A refrigerant with zero ODP (Ozone Depletion Potential). The range has been specificallydesigned for today's building requirements and addresses key market issues such as energy efficiency,adaptability and reliability. Mitsubishi Electric manufactures the only 2-pipe heat recoverysimultaneous heating and cooling system in the world and equally unique, a water-cooled version. With user fr iendly control systems utilising Internet technology and integrated cooling and ventilation indoor units, City Multi is the benchmark and market leader in VRF technology.

What is inverter driven technology?Mitsubishi Electric spends more than 5% of its turnover on research and development, with ourengineers always looking at ways in which we can improve and lead in air conditioning efficiency. The use of inverter technology in our City Multi systems is paramount in this process, working byvarying the compressor speed to match the cooling or heating load, thereby consuming only thepower necessary to match the exact requirement of the room. When City Multi is operating atpartial load, the energy efficiency of the system is significantly higher than at full load. In a typicalapplication partial load conditions prevail for more than 90% of operation time. A fixed speed systemcan only operate at 100% capacity and cannot match the annual efficiencies of an inverter system

What is a Heat Pump system?Mitsubishi Electric’s City Multi Y Series, is a heat pump system, which provides either heating orcooling to a building at any given time.

What is a Heat Recovery system?Mitsubishi Electric’s City Multi R2 and WR2 series’ have the ability to provide heating and cooling atthe same time in areas connected to the same outdoor unit.

The Basics

Page 120

Page 122: 2008 Product Catalogue

The secret of City Multi heat recovery systems lies in the

BC Controller

How does the R2 / WR2 Heat Recovery System operate on 2 Pipe’s?

The BC Controller houses a liquid/gas separator, allowing the outdoor unit to deliver a mixture (2 phase) of hot gas for heating and liquid for cooling, all through the same pipe. Three pipe systemsallocate a pipe to each of these phases. When this mixture arrives at the BC Controller, it is separated and the correct phase delivered to each indoor unit depending on the individual requirement ofeither heating or cooling.

Why R410A?R410A is a more efficient refrigerant as it has a higher specificheat capacity when compared to R407c or R22. This higherenergy carrying capacity allows for smaller pipe sizes, longer piperuns and reduces the volume of refrigerant within a system.

This is a major factor when complying with EN378, aEuropean standard concerning safety and environmentalrequirements in the design, manufacture, installation,operation, maintenance and disposal of refrigerating systems.

Comparison example of piping connection sites

= 2 sites = 3 sites

Why Heat Recovery?Flexibility and efficiency are key factors when selecting a heatrecovery system. For example, while a heat pump system isadequate for a large open plan office, businesses that have amore partitioned structure to an office will require the needto simultaneously heat or cool different sections of the officeaccording to each users individual preferences.

The efficiency of this type of system comes from the ability touse the by-products of cooling and heating to transfer energywhere it is required, thus acting as a balanced heat exchangerachieving up to 20% cost savings over a conventional heatpump system.

The number of connection sites needed for a R2 / WR2system are also significantly lower than those needed for athree pipe version. This helps to reduce installation costs,further increasing the savings associated with City Multi.

Page 121

Page 123: 2008 Product Catalogue

The technology to makeCity Multi the natural choice

City Multi R410A YHM-A technologyUsing the very latest in IPM (Intelligent Power Module) technology, precise control ofenergy input is achieved allowing City Multi to fur ther improve COPs for R410A systems.IPM uses 1Hz steps of capacity control, matching building requirements through more accuratecontrol of the occupied space with reduced power input.

As in previous versions, IPM technology operates extremely effectively under part load conditions(50-80% of operating capacity), a condition that most systems will be in for their normal working life.Therefore the consideration of efficiency at part load is accounted for as well as when at peak loadconditions, offering high system efficiency all year round.

Energy efficiency has always been the driver for City Multi technologicaldevelopment. Technology that always delivers the quality and reliability neededfor commercial air conditioning environments. Mitsubishi Electric spend morethan 5% of their turnover on research and development, with our engineers alwayslooking at ways in which we can improve and lead in air conditioning efficiency.

Stable and smooth operation - 100% inverter control

All City Multi compressors are inverter-driven - Capable of precisely matching abuilding's cooling and heating demands.

The outdoor unit combinations comprise of one module for 8-18hp systems (for R2 up to16hp), two modules for 20-36hp systems (for R2, 18-32hp) and three modules for 38-50hpsystems (Y series only). Each module carries one inverter compressor making simple and highlyreliable control possible. Not only does it allow low starting currents, the inverter drivencompressor also provides precise indoor comfort and adapts to the air conditioning load, achieving smooth transition across the range of compressor frequencies.

Page 122

Y Series 8-18hp / R2 8-16hp Y Series 20-36hp / R2 18-32hp Y Series 38-50hp

Page 124: 2008 Product Catalogue

Total Energy Conservation

Total Energy Conservation

Comparison of COP (energy efficiency) of an 8hp YHM-A system.

The difference between YHM-A and previousMitsubishi Electric models

Technology is key when increasedefficiency is demanded. The City MultiYHM-A range is designed to deliver this.

A highly efficient R410A scroll compressordesign results in less friction losses at the motor.A simplified refrigerant circuit (low pressure loss)including new accumulator design also adds afew more points to the efficiency scale.

Enhancements to the heat interchange circuit,inverter driven fan motor and heat exchangerdesign, again add vital increases to overall systemefficiency and COPs.

CITY MULTI REFRIGERANT

CIRCUIT

NORMAL REFRIGERANT

CIRCUIT

Heat Interchange CircuitTo further enhance the class leading efficiency of City Multi, the unique HeatInterchange Circuit provides extra sub cooling. This system allows optimumrefrigerant distribution to multiple indoor units, by allowing more effective use of refrigerant flowing through the electronic expansion valves.

Because of the added efficiency, volumes of refrigerant in systems arecontinuing to reduce.

The importance of COPCOP stands for “Co-efficient of Performance”. It is a measure of theuseful energy a system can deliver compared to the energy that it consumes. It is calculated by dividing the energy output by the energy input of a system. The higher the figure then the moreefficient the system is deemed to be, with commensurate reducedrunning costs.

For Heat Pumps to be included on the Energy Technology Product Listunder the Enhanced Capital Allowance scheme, they must achieve aheating COP of 3.4 and a cooling EER (energy efficiency ratio) of 3.0.Therefore every input of 1kW of energy must deliver an output of 3.4kW for heating and 3.0kW for cooling, achieving an energy label of B.

Page 123

Page 125: 2008 Product Catalogue

Ground SourceHeat Pumps

A very efficient source of energy for water source heat pump systems is the Earthitself. Ground source heat pumps use the Earth's natural solar collection and heatstorage capabilities as an infinite heat source/heat sink.At between 1.7m and 3m below the ground, the temperature changes from 17ºC in the summer to 10ºC in the winter.Deeper down however, the temperature of the ground is a constant 10ºC all year round. It is these relatively constant,dependable temperatures that can be harnessed using ground source heat pumps.

The constant ground temperatures allow the heat pump to operate at optimum efficiency in both heating and cooling, as the high summer or low winter temperatures do not influence performance. Heat is extracted or rejected into the ground using water which is pumped through a network of plastic pipes.

There are two standard ground source methods available, Open Loop and Closed Loop (Bore Hole or Slinky):

� Open Loop - Large bodies of water can be utilised as a stable source of water at arelatively constant temperature. This can be either surface water or ground water.Surface water would include lakes, reservoirs, rivers and the sea.

� Closed Loop Slinky - A trench is dug to a depth of between 1.7 to 3m and plastic spiral pipe is laid into the bottom. The pipe is covered with sand to provide good ground to pipe contact and then the trench is backfilled with the excavated soil.

� Closed Loop Bore Hole - A series of holes are drilled down into the ground at a depth of 50 to 130m, depending on geothermal conditions. Two water pipes connected via a 'u bend' are fed directly into these holes and then surrounded by a conductive grout.

Ground Source Heat Pump installed insidethe building, typically 1 per floor

Bore Hole absorbs or rejects heat from the ground

Flow and return water loop supplies water to and from the units

Indoor units provide heating or cooling

Example of a Closed Loop Bore Hole Application:

Page 124

Page 126: 2008 Product Catalogue

A range of Acoustic Kits designed for noise reduction. An industry first, the kits offer a 6dBA noise level reduction from standard.

For supply and / or installation please contact

Ambient Acoustics on 01934 712802

New Acoustic Kits for PUHY and PURY Series units

Highly eff icient &extremely f lexible

Page 125

Page 127: 2008 Product Catalogue

Features andHigh off coil / High sensible coolingPoor design or application of air conditioning systems can sometimes lead to cold draughts anduneven room temperatures. Low off coil temperatures cause dehumidifying of the air which cancreate dry eyes and sore throats.

Mitsubishi Electric now provides a High Sensible Cooling Function specifically designed to deal withthis. By raising the off coil temperature, a 10% increase in sensible cooling capacity over standardoperation is achievable, the result being greater comfort for occupants. These high SHF’s are availablethroughout the range of indoor units, allowing optimum selection of units tailored to more specificdesign criteria.

Reduced noise levelsNew fan designCity Multi VRF systems led the introduction of larger single fan rotors some ten years ago, achievingsubstantially lower noise levels over multiple designs. Continuing the development in the areas of bladeshape and weight, Mitsubishi Electric have managed to achieve even higher performance and lowernoise levels.

To reduce noise levels further and comply with inner city residential noise regulations, all outdoor unitsinclude Night Set-back mode. This function works by lowering the fan speed and compressorfrequency proportionally with reduction in demand (44dBA for PUHY-P250YHM-A). The compressorcompartment is also now sealed, further reducing noise levels.

Page 126

New fan designReduction of operation noise

New heat exchanger designImprovement of COP

New inverter compressorImprovement of COP

New control box designImprovement of reliability and easy maintenance

Page 128: 2008 Product Catalogue

Benefits

Fine Control of the Inverter ProvidesBetter Eff iciency and PerformanceAir cooled inverters use the ambient temperature to cool the inverter. For water cooled VRF (whichare installed inside the building) refrigerant cooling is used to maintain accurate control of the Inverter.

Refrigerant volume checking functionThis function runs the system, measuring various temperatures and pressures throughout thesystem, comparing these to the values stored in the units memory from the previous service.If a leakage has occurred the system will indicate so, enabling customers to easily comply withthe F-Gas regulation.

Replace technologyThis unique function allows the re-use of refrigerant piping, controllers, power and controlwiring for all previously installed Mitsubishi Electric R22 and R407c Heat Recovery and Coolingonly systems and partial replace of Heat Pumps (pressure regulations require one pipe fromthe outdoor to the first branch to be replaced). This function offers unprecedented savings oninstallation costs, disruption to business and down time, not to mention the considerablerunning cost and CO2 emission savings - more than halving the running costs compared to a10 year old unit.

Cooling operation set temperature of 14ºCEnvironments such as gyms, laboratories etc often require the ability to cool lower than the standardcomfort cooling setpoint. By selecting a dip switch on the unit, a cooling operation settemperature of 14ºC DB is possible on the floor standing and ducted models only. The indoorunit fan will be fixed at high speed during this operation.

Page 127

Page 129: 2008 Product Catalogue

YGM-A YHM-A

YGM-A YHM-A

8-12hp systems (Y / R2 Series) 1.43m2

14-18hp systems (Y Series)14-16hp systems (R2 Series)

1.89m2

mm

33kg

Approximately 21% reduction in foot print(PUHY-P250)

The unit can easily be transported, even into inaccessible buildings

The downsized outdoor unit can be transported through an 800mm wide lift door

The narrow space between buildings makes it difficult to use a crane

8-12hp outdoor units Example of lift

Effective use of spaceThe new models have a smaller foot print requirement than previous models. The width and depthhave been reduced by 7% and 13% respectively, with the height being reduced by 130mm.

(PUHY-P250YHM-A compared to previous YGM-A versions).

Weight reductionWeight has been reduced by approximately 33kg

(PUHY-P250YHM-A compared to previous YGM-A versions).

Page 128

Page 130: 2008 Product Catalogue

Blue Fin treatmentThe anti-corrosion Blue Fin treatment of the heat exchanger is especially effective in urban environments where the traffic pollutions can damage the aluminium fins reducing the capacity and life expectancy of the unit.

All City Multi R410A outdoor units have been treated with Blue Fin

R410A pipe sizingAs R410A has a higher specific heat capacity than R22, the pipework is smaller. This means the pipe itself is cheaper, easier to install and less riser space is required within the building.

10hp model

Water temperature operation range -WR2 / WY Water cooled units

Page 129

Heating operation range -Air cooled unitsAt low ambient temperatures the guaranteed operating range in heating is minus 20ºC

Operating range in cooling is from an outdoor temperature of -5ºC.

Constant & comfortableindoor climates

Outdoor Temperature (ºC) Water Temperature (ºC)

Page 131: 2008 Product Catalogue

City Multi exceedscurrent demands for Eff iciencyThe need for energy efficiency is paramount and is determined by legislation and regulation.Businesses saw their energy bills rise by up to 15% with the introduction of the Climate ChangeLevy in April 2001. A year later, the newly revised Par t L (Par t J in Scotland) of the buildingregulations placed new standards on design of buildings and plant deployed for heating, cooling andventilating. A revised version to conform with the Energy Performance of Buildings Directive was alsointroduced in 2006; all geared to reducing energy consumption and therefore CO2 emissions.

To encourage efficient use of energy, the UK Government introduced the Enhanced CapitalAllowance Scheme (ECA). Qualifying products on the Energy Technology Product List include heatpumps for space heating. The City Multi range has been designed to ensure businesses qualify forECA and benefit from the utmost efficiency, both financially and environmentally.

Mitsubishi Electric has produced a series of comprehensive CPD approved guides.These include:

Page 130

� The Energy Performance of Buildings Directive (EPBD)

� Mixed Mode Cooling Systems

� Building Energy Management Systems (BEMS)

� Water Cooled VRF Systems

� The European F-Gas Regulation

� The New Part L of the Building Regulations 2006

� The New 10% Renewable Energy Target

� Heat Pump Boilers

� Part F of the Building Regulations

� The Code for Sustainable Homes

� Building Energy Ratings

� Renewable Energy Sources

� Maintenance, Replacement and the WEEE Directive

� Combined Heat and Power

� Carbon Reduction in the Built Environment

� The Application of Heat Pump Boilers

� The Enhanced Capital Allowance Scheme (2008)

Page 132: 2008 Product Catalogue

� Under the scheme, all businesses liable for UK corporation tax, are able to claim an enhanced capital allowance on any qualifying expenditure (regardless of size and location of business or whether in the industrial or commercial sector)

� Businesses can offset the full cost of specific technologies (such as City Multi) against taxable profits of the period of the investment

� In order to qualify for this scheme, technology has to meet the energy saving criteria as published in the Energy Technology Criteria List. City Multi fully meets this criteria in its drive for energy efficiency

� Only investment in new and unused plant and machinery qualify

For further information go to www.eca.gov.uk and click on Mitsubishi Electric Air Conditioning under the heat pump category.

Enhanced Capital Allowance Scheme (ECA)

The key features of the scheme:

Page 131

Page 133: 2008 Product Catalogue

A wide choice of models

The model line up

The new YHM-A air sourced outdoor models are modular in design and as such differingcombinations of them can be connected together to create the required outdoor unit size neededfor a particular application.

Both the Y Series and R2 ranges come in standard (-P) and high COP (-EP) versions. In addition, the standard versionsallow for space-saving by virtue of the combination of units having a smaller foot print than the high COP versions.

Y Series Heat Pump - Standard Version

Series

Y

R2

Size

Model Name

PUHY-P YHM-A

PUHY-EP YHM-A

PURY-P YHM-A

PURY-EP YHM-A

200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250

8hp 10hp 12hp 14hp 16hp 18hp 20hp 22hp 24hp 26hp 28hp 30hp 32hp 34hp 36hp 38hp 40hp 42hp 44hp 46hp 48hp 50hp

� � � � � � � � � � � � � � � � � � � � �

� � � � � � � � � � � � �

� � � � � � � � � � �

� � � � � � �

10hp

PUHY-P250YHM-A

12hp

PUHY-P300YHM-A

Y Series (10-12hp) PUHY-P YHM-A

28hp

PUHY-P700YSHM-A

30hp

PUHY-P750YSHM-A

32hp

PUHY-P800YSHM-A

Y Series (28-36hp) PUHY-P YSHM-A

14hp

PUHY-P350YHM-A

16hp

PUHY-P400YHM-A

18hp

PUHY-P450YHM-A

Y Series (14 -18hp) PUHY-P YHM-A

38hp

PUHY-P950YSHM-A

40hp

PUHY-P1000YSHM-A

Y Series (38 -40hp) PUHY-P YSHM-A

20hp

PUHY-P500YSHM-A

22hp

PUHY-P550YSHM-A

24hp

PUHY-P600YSHM-A

26hp

PUHY-P650YSHM-A

Y Series (20 -26hp) PUHY-P YSHM-A

42hp

PUHY-P1050YSHM-A

Y Series (42hp) PUHY-P YSHM-A

44hp

PUHY-P1100YSHM-A

46hp

PUHY-P1150YSHM-A

48hp

PUHY-P1200YSHM-A

50hp

PUHY-P1250YSHM-A

Y Series (44-50hp) PUHY-P YSHM-A

34hp

PUHY-P850YSHM-A

36hp

PUHY-P900YSHM-A

Page 132

Page 134: 2008 Product Catalogue

Y Series Heat Pump - High COP Version

8hp

PUHY-EP200YHM-A

12hp

PUHY-EP300YHM-A

Y Series - High COP (8 -12hp) PUHY-EP YHM-A

Y Series - High COP (28-30hp) PUHY-EP YSHM-A

16hp

PUHY-EP400YSHM-A

18hp

PUHY-EP450YSHM-A

20hp

PUHY-EP500YSHM-A

Y Series - High COP (16-20hp) PUHY-EP YSHM-A

32hp

PUHY-EP800YSHM-A

34hp

PUHY-EP850YSHM-A

28hp

PUHY-EP700YSHM-A

30hp

PUHY-EP750YSHM-A

Y Series - High COP (32-34hp) PUHY-EP YSHM-A

Y Series - High COP (22-26hp) PUHY-EP YSHM-A

36hp

PUHY-EP900YSHM-A

Y Series - High COP (36hp) PUHY-EP YSHM-A

22hp

PUHY-EP550YSHM-A

24hp

PUHY-EP600YSHM-A

26hp

PUHY-EP650YSHM-A

R2 Series Heat Recovery - Standard Version

10hp

PURY-P250YHM-A

12hp

PURY-P300YHM-A

R2 Series (10 -12hp) PURY-P YHM-A

R2 Series (26 -28hp) PURY-P YSHM-A

R2 Series (14 -16hp) PURY-P YHM-A

30hp

PURY-P750YSHM-A

32hp

PURY-P800YSHM-A

26hp

PURY-P650YSHM-A

28hp

PURY-P700YSHM-A

R2 Series (30 -32hp) PURY-P YSHM-A

R2 Series (18 -24hp) PURY-P YSHM-A

14hp

PURY-P350YHM-A

16hp

PURY-P400YHM-A

20hp

PURY-P500YSHM-A

22hp

PURY-P550YSHM-A

24hp

PURY-P600YSHM-A

R2 Series Heat Recovery - High COP Version

8hp

PURY-EP200YHM-A

12hp

PURY-EP300YHM-A

R2 Series - High COP (8 -12hp) PURY-EP YHM-A R2 Series - High COP (16-18hp) PURY-EP YSHM-A

24hp

PURY-EP600YSHM-A

R2 Series - High COP (24hp) PURY-EP YSHM-A

R2 Series - High COP (20-22hp) PURY-EP YSHM-A

16hp

PURY-EP400YSHM-A

18hp

PURY-EP450YSHM-A

20hp

PURY-EP500YSHM-A

22hp

PURY-EP550YSHM-A

Page 133

Page 135: 2008 Product Catalogue

City Multi Product Range OverviewOutdoor Units14kW Cooling Capacity

PQ(H/R)Y-P200/250YGM-A

WY / WR2Y Series (4/5/6hp)

Model / Size

PLFY-P-VBM-E

PLFY-P-VCM-E

PLFY-P-VLMD-E

PMFY-P-VBM-E

PEFY-P-VMS1-E

PEFY-P-VMM-E

PEFY-P-VMH-E

PCFY-P-VGM-E

PKFY-P-VBM/VGM/VFM-E

PFFY-P-VLRM-E

PFFY-P-VLRMM-E

PFFY-P-VLEM-E

PFFY-P-VKM-E

GUF-RD3

PQFY-P

15(1.7kW)

20(2.2kW)

25(2.8kW)

32(3.6kW)

40(4.5kW)

Indoor Units

PUMY-P100-140V/YHMA

Page 134

PQ(H/R)Y-P400/500YSGM-A

WY / WR2

Page 136: 2008 Product Catalogue

63(7.1kW)

80(9.0kW)

100(11.2kW)

125(14.0kW)

140(16.0kW)

250(28.0kW)

140kW Cooling Capacity

PUH/RY-EP200YHM-A

Y / R2 Series High COP

PUH/RY-P350-450YHM-A*1

Y / R2 Series Standard

50(5.6kW)

Page 135

*1 Size 450 only available for Y Series

PUH/RY-P250/300YHM-A

Y / R2 Series Standard

PUH/RY-EP300YHM-A

Y / R2 Series High COP

Page 137: 2008 Product Catalogue

The energy efficient

City Multi VRF range

Unique 2-pipe technology provides

simultaneous heating and cooling, alongside excellent energy

efficiency and corresponding EER/COP

ratings. Up to 50 indoor units can be connected to a single

outdoor unit, offering the sophistication,

control and energy efficiency

demanded today.

Systems marked with the ECA logo are registered on the Energy Technology List andhence qualify for 100% first year enhanced capital allowances (whole system cost and‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk

Nominal conditions cooling: indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.Nominal conditions heating: indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. Winter; indoor 21˚C DB; outdoor -1˚C WB.

S imple technologyat its best

Page 136

Page 138: 2008 Product Catalogue

Y Series (4-6hp) Heat Pump, Outdoor Unit

Y Series Standard (10-18hp) Heat Pump, Outdoor Unit

Y Series Standard (20-36hp) Heat Pump, Outdoor Unit

Y Series Standard (38-50hp) Heat Pump, Outdoor Unit

Y Series High COP (8-26hp) Heat Pump, Outdoor Unit

Y Series High COP (28-36hp) Heat Pump, Outdoor Unit

WY Series (8-20hp) Water Cooled Heat Pump, Outdoor Unit

R2 Series Standard (10-16hp) Heat Recovery, Outdoor Unit

R2 Series Standard (20-32hp) Heat Recovery, Outdoor Unit

R2 Series High COP (8-24hp) Heat Recovery, Outdoor Unit

R2 Series Piping Restrictions

WR2 Series (8-20hp) Water Cooled Heat Recovery, Outdoor Unit

PFD-P-VM-E Heat Pump, Close Control System

PLFY-P-VBM-E 2, 3 and 4-Way Blow Ceiling Cassette Indoor Unit

PLFY-P-VCM-E 600x600 4-Way Blow Ceiling Cassette Indoor Unit

PLFY-P-VLMD-E 2-Way Blow Ceiling Cassette Indoor Unit

PMFY-P-VBM-E 1-Way Blow Ceiling Cassette Indoor Unit

PEFY-P-VMS1-E Ultra Thin Ceiling Concealed Ducted Indoor Unit

PEFY-P-VMM-E Ceiling Concealed Ducted Indoor Unit

PEFY-P-VMH-E High Static Pressure Ceiling Concealed Ducted Indoor Unit

PCFY-P-VGM-E Ceiling Suspended Indoor Unit

PKFY-P-VBM/VGM/VFM-E Wall Mounted Indoor Unit

PFFY-P-VLRM-E Floor Standing Concealed Indoor Unit

PFFY-P-VLRMM-E Floor Standing Concealed Indoor Unit

PFFY-P-VLEM-E Floor Standing Exposed Indoor Unit

PFFY-P-VKM-E Floor Standing Exposed Indoor Unit

GUF-RD3 Lossnay Outdoor Air Processing Unit

PQFY-P VRF Heat Pump Boiler

BC Controllers

Air Handling Unit Controllers

Accessories / Optional Extras

138

140

142

144

146

148

150

152

154

156

158

160

162

164

166

168

170

172

174

176

178

180

182

184

186

188

190

192

194

196

197

Contents

Page 137

Page 139: 2008 Product Catalogue

Heat Pump Outdoor Unit

Y Series (4-6hp)

Y SERIES OUTDOOR UNIT - 4-6hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

COP / EER (nominal)

Max no. OF CONNECTABLE INDOOR UNITS

Max CONNECTABLE CAPACITY

AIRFLOW (m3/min)

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

GUARANTEED OPERATING RANGE Cooling

Heating

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

PUMY-P100VHMA

12.5

11.2

10.4

10.3

3.66

3.34

3.27

2.84

3.42 / 3.35

6

14.5 (130%)

100

15.88 (5/8”)

9.52 (3/8”)

51 / 49

127

950

330+30

1350

220-240v, 50Hz

Single

5

15.5

14.1

-5ºC ~ 46ºC

-15ºC ~ 15ºC

40

3

PUMY-P125VHMA

16.0

14.0

13.3

12.9

4.33

4.32

3.85

3.66

3.69 / 3.24

8

18.2 (130%)

100

15.88 (5/8”)

9.52 (3/8”)

52 / 50

127

950

330+30

1350

220-240v, 50Hz

Single

5

18.3

18.3

-5ºC ~ 46ºC

-15ºC ~ 15ºC

40

3

PUMY-P140VHMA

18.0

15.5

14.9

14.3

5.58

5.35

4.99

4.53

3.23 / 2.90

8

20.2 (130%)

100

15.88 (5/8”)

9.52 (3/8”)

53 / 51

127

950

330+30

1350

220-240v, 50Hz

Single

5

23.6

22.7

-5ºC ~ 46ºC

-15ºC ~ 15ºC

50

3

PUMY-P100-140VHMA/YHMA Piping RestrictionsTOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

120m max

80m max

30m max

30m max (20m max if outdoor installed below)

12m max

Optional PartsModel Name DescriptionCMY-Y62-G-E Branch Pipe (2 Branch)

PUMY-P100YHMA

12.5

11.2

10.4

10.3

3.63

3.3

3.23

2.81

3.44 / 3.39

6

14.5 (130%)

100

15.88 (5/8”)

9.52 (3/8”)

51 / 49

140

950

330+30

1350

380-415v, 50Hz

3

5

5.32

4.84

-5ºC ~ 46ºC

-15ºC ~ 15ºC

16

4 + earth

PUMY-P125YHMA

16.0

14.0

13.3

12.9

4.29

4.27

3.82

3.63

3.73 / 3.28

8

18.2 (130%)

100

15.88 (5/8”)

9.52 (3/8”)

52 / 50

140

950

330+30

1350

380-415v, 50Hz

3

5

6.29

6.26

-5ºC ~ 46ºC

-15ºC ~ 15ºC

16

4 + earth

PUMY-P140YHMA

18.0

15.5

14.9

14.3

5.32

5.32

4.73

4.52

3.38 / 2.91

8

20.2 (130%)

100

15.88 (5/8”)

9.52 (3/8”)

53 / 51

140

950

330+30

1350

380-415v, 50Hz

3

5

7.8

7.8

-5ºC ~ 46ºC

-15ºC ~ 15ºC

16

4 + earth

Technical Information

The latest in Mitsubishi Electric R410A Y Series technology. The new City Multi models allow up to 8 indoor units to be connected to a single outdoor unit, using the standard branch/header pipework systemproven in the larger models. Utilising the latest Mitsubishi Electric inver ter technology, the system is fu l ly controllable with all City Multi controllers or linked to third party BEMS.

� A two core non-polar transmission line allows for simple installation of up to eight indoor units

� Latest in inverter technology including a highly efficient DC Scroll Compressor, DC fan motor and Demand Control

� The condensing unit is extremely slimline which allows easy location and application of the system

� Single or three phase power supply

� Anti-Corrosion blue and flat fin technology

� Size 15 PEFY-P-VMS1-E now able to connect to PUMY

Page 138

Page 140: 2008 Product Catalogue

Upper View >

Side View > Front View >

PUMY-P100-140VHMA/YHMA

Cit

y M

ulti

Ran

ge 2

008

Y S

erie

s (4

-6hp

)

Dimensions

Page 139

Page 141: 2008 Product Catalogue

Heat Pump Outdoor Unit

Y SERIES STANDARD OUTDOOR UNITS 10-18hp

Y Series Standard (10-18hp)

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

COP/EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PUHY-P250YHM-A

31.5

28.0

28.7

26.6

7.83

7.73

7.75

4.79

4.02 / 3.62

21

185

57

200

920

760

1710

380-415v, 50Hz

3

8

12.1

11.9

32

4 + earth

PUHY-P300YHM-A

37.5

33.5

33.0

31.5

9.39

9.07

9.11

6.71

3.99 / 3.69

26

185

59

215

920

760

1710

380-415v, 50Hz

3

8

14.5

14.0

32

4 + earth

PUHY-P350YHM-A

45.0

40.0

39.6

37.6

12.09

11.20

11.73

8.29

3.72 / 3.57

30

225

60

245

1220

760

1710

380-415v, 50Hz

3

8

18.6

17.3

32

4 + earth

PUHY-P400YHM-A

50.0

45.0

44.0

42.3

13.47

13.23

13.07

9.79

3.71 / 3.40

34

225

61

245

1220

760

1710

380-415v, 50Hz

3

8

20.8

20.4

40

4 + earth

PUHY-P450YHM-A

56.0

50.0

48.7

46.0

15.38

16.28

14.00

11.40

3.64 / 3.07

39

225

62

245

1220

760

1710

380-415v, 50Hz

3

8

23.7

25.1

50

4 + earth

PUHY-P250-450YHM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

1000m max

165m max

40m max

50m max (40m max if outdoor installed below)

15m max

Improved for even higher efficiency

Technical Information

The City Multi Y series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

� New wrap around coil for improved energy efficiency

� Choice of Branch Pipe or Header Pipe feeds to indoor units

� Energy-saving inverter driven outdoor compressor units with very low start currents

� No requirement for plant rooms or bulky service shafts

� Weight and size reduction compared to previous YGM-A models

� Improved pipe run of 165m, with a total system pipe length of 1000m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

Page 140

Page 142: 2008 Product Catalogue

PUHY-P250, 300YHM-A

PUHY-P350, 400, 450YHM-A

Upper View >

Upper View >

Cit

y M

ulti

Ran

ge 2

008

Y S

erie

s St

anda

rd (

10-1

8hp)

Dimensions

Front View >Side View >

Front View >Side View >

Page 141

Page 143: 2008 Product Catalogue

PUHY-P500-900YSHM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

1000m max

165m max

40m max

50m max (40m max if outdoor installed below)

15m max

Heat Pump Outdoor Unit

Y Series Standard (20-36hp)

Improved for even higher efficiency

Technical Information

The City Multi Y series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

� New wrap around coil for improved energy efficiency

� Choice of Branch Pipe or Header Pipe feeds to indoor units

� Energy-saving inverter driven outdoor compressor units with very low start currents

� No requirement for plant rooms or bulky service shafts

� Weight and size reduction compared to previous YGM-A models

� Improved pipe run of 165m, with a total system pipe length of 1000m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

Page 142

Y SERIES STANDARD OUTDOOR UNITS 20-36hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

COP/EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PUHY-P500YSHM-A

63.0

56.0

54.8

51.5

16.40

16.47

14.92

11.53

3.84 / 3.40

43

185 / 185

60

200 + 200

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

25.3

25.4

32 / 32

4 + earth

PUHY-P550YSHM-A

69.0

63.0

60.0

58.0

18.06

18.36

16.43

12.85

3.82 / 3.43

47

185 / 185

60.5

215 + 200

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

27.9

28.3

32 / 32

4 + earth

PUHY-P600YSHM-A

76.5

69.0

66.6

63.5

19.92

18.75

18.13

13.13

3.84 / 3.68

50

225 / 185

60.5

245 + 200

1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8

30.7

28.9

32 / 32

4 + earth

PUHY-P650YSHM-A

81.5

73.0

70.9

67.2

21.90

20.79

19.93

14.55

3.72 / 3.51

50

225 / 185

61

245 + 215

1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8

33.8

32.1

32 / 32

4 + earth

PUHY-P700YSHM-A

88.0

80.0

75.7

73.6

23.71

22.47

22.05

16.18

3.71 / 3.56

50

225 / 225

61

245 + 245

1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

36.6

34.7

32 / 32

4 + earth

PUHY-P750YSHM-A

95.0

85.0

81.7

78.2

25.46

25.07

23.68

18.05

3.73 / 3.39

50

225 / 225

63

245 + 245

1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

39.3

38.7

40 / 32

4 + earth

PUHY-P800YSHM-A

100.0

90.0

86.0

82.8

25.70

27.69

23.90

19.94

3.89 / 3.25

50

225 / 225

64

245 + 245

1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

39.7

42.8

50 / 32

4 + earth

PUHY-P850YSHM-A

108.0

96.0

95.0

88.3

28.42

30.18

26.15

19.92

3.80 / 3.18

50

225 / 225

64.5

245 + 245

1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

43.9

46.6

50 / 40

4 + earth

PUHY-P900YSHM-A

113.0

101.0

99.4

92.9

30.29

33.33

27.87

22.00

3.73 / 3.03

50

225 / 225

64.5

245 + 245

1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

46.8

51.5

50 / 50

4 + earth

Page 144: 2008 Product Catalogue

PUHY-P500, 550YSHM-A

PUHY-P600, 650YSHM-A

Cit

y M

ulti

Ran

ge 2

008

Y S

erie

s St

anda

rd (

20-3

6hp)

Dimensions

Side View > Front View >

Side View > Front View >

Side View > Front View >

PUHY-P700, 750, 800, 850, 900YSHM-A

Page 143

Page 145: 2008 Product Catalogue

PUHY-P950-1250YSHM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

1000m max

165m max

40m max

50m max (40m max if outdoor installed below)

15m max

Heat Pump Outdoor Unit

Y Series Standard (38-50hp)

Improved for even higher efficiency

Technical Information

The City Multi Y series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

� New wrap around coil for improved energy efficiency

� Choice of Branch Pipe or Header Pipe feeds to indoor units

� Energy-saving inverter driven outdoor compressor units with very low start currents

� No requirement for plant rooms or bulky service shafts

� Weight and size reduction compared to previous YGM-A models

� Improved pipe run of 165m, with a total system pipe length of 1000m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

Page 144

Y SERIES STANDARD OUTDOOR UNITS 38-50hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

COP/EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PUHY-P950YSHM-A

119.5

108.0

105.2

99.4

30.02

30.68

27.62

20.25

3.98 / 3.52

50

185 / 185 / 185

64

245 + 215 + 200

1220 + 920 + 920

760

1710

380-415v, 50Hz

3

8 / 8 / 8

46.4

47.4

40 / 32 / 32

4 + earth

PUHY-P1000YSHM-A

127.0

113.0

111.8

104.0

33.15

32.47

30.50

21.43

3.83 / 3.48

50

225 / 185 / 185

64

245 + 215 + 215

1220 + 920 + 920

760

1710

380-415v, 50Hz

3

8 / 8 / 8

51.2

50.1

40 / 32 / 32

4 + earth

PUHY-P1050YSHM-A

132.0

118.0

116.2

108.6

35.01

33.90

32.21

22.37

3.77 / 3.48

50

225 / 225 / 185

64

245 + 245 + 200

1220 + 1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8 / 8

54.1

52.4

40 / 32 / 32

4 + earth

PUHY-P1100YSHM-A

140.0

124.0

123.2

114.1

36.93

35.83

33.98

23.65

3.79 / 3.46

50

225 / 225 / 225

64

245 + 245 + 245

1220 + 1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8 / 8

57.0

55.3

40 / 32 / 32

4 + earth

PUHY-P1150YSHM-A

145.0

130.0

127.6

119.6

39.08

39.39

35.95

26.00

3.71 / 3.30

50

225 / 225 / 225

64.5

245 + 245 + 245

1220 + 1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8 / 8

60.4

60.8

50 / 32 / 32

4 + earth

PUHY-P1200YSHM-A

150.0

136.0

132.0

125.1

40.10

41.71

36.89

27.53

3.74 / 3.26

50

225 / 225 / 225

65

245 + 245 + 245

1220 + 1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8 / 8

61.9

64.4

50 / 40 / 32

4 + earth

PUHY-P1250YSHM-A

156.5

140.0

137.7

128.8

42.06

45.01

38.70

29.71

3.72 / 3.11

50

225 / 225 / 225

65.5

245 + 245 + 245

1220 + 1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8 / 8

65.0

69.5

50 / 50 / 32

4 + earth

Page 146: 2008 Product Catalogue

PUHY-P950, 1000YSHM-A

PUHY-P1050YSHM-A Cit

y M

ulti

Ran

ge 2

008

Y S

erie

s St

anda

rd (

38-5

0hp)

Dimensions

Side View > Front View >

Side View > Front View >

Side View > Front View >

PUHY-P1100, 1150, 1200, 1250YSHM-A

Page 145

Page 147: 2008 Product Catalogue

Heat Pump Outdoor Unit

Y Series High COP (8-26hp)

PUHY-EP200-650Y(S)HM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

1000m max

165m max

40m max

50m max (40m max if outdoor installed below)

15m max

Improved for even higher efficiency

Technical Information

The City Multi Y series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

� Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil

� Choice of Branch Pipe or Header Pipe feeds to indoor units

� Energy-saving inverter driven outdoor compressor units with very low start currents

� No requirement for plant rooms or bulky service shafts

� Weight and size reduction compared to previous YGM-A models

� Improved pipe run of 165m, with a total system pipe length of 1000m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

Y SERIES HIGH COP OUTDOOR UNIT 8-26hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

COP/EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PUHY-EP200YHM-A

25.0

22.4

23.0

21.3

5.77

5.18

5.71

3.21

4.33 / 4.32

17

185

57

200

920

760

1710

380-415v, 50Hz

3

8

8.9

8.0

20

4 + earth

PUHY-EP300YHM-A

37.5

33.5

33.0

31.5

9.28

8.25

9.00

6.11

4.04 / 4.06

26

225

60

245

1220

760

1710

380-415v, 50Hz

3

8

14.3

12.7

32

4 + earth

PUHY-EP400YSHM-A

50.0

45.0

44.0

42.3

11.54

10.41

11.19

7.70

4.33 / 4.32

34

185 / 185

60

200 + 200

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

17.8

16.0

20 / 20

4 + earth

PUHY-EP450YSHM-A

56.0

50.0

48.7

46.0

13.05

13.15

11.88

9.21

4.29 / 3.80

39

185 / 185

60

200 + 200

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

20.1

20.3

32 / 20

4 + earth

PUHY-EP500YSHM-A

63.0

56.0

54.8

51.5

15.14

13.46

13.78

9.42

4.16 / 4.16

43

225 / 185

62

245 + 200

1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8

23.4

20.8

32 / 20

4 + earth

PUHY-EP550YSHM-A

69.0

63.0

60.0

58.0

17.12

16.32

15.58

11.42

4.03 / 3.86

47

225 / 185

62

245 + 200

1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8

26.4

25.2

32 / 32

4 + earth

PUHY-EP600YSHM-A

76.5

69.0

66.6

63.5

18.93

16.99

17.23

11.89

4.04 / 4.06

50

225 / 225

63

245 + 245

1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

29.2

26.2

32 / 32

4 + earth

PUHY-EP650YSHM-A

81.5

73.0

70.9

67.2

19.13

18.34

17.41

12.84

4.26 / 3.98

50

225 / 225

63

245 + 245

1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

29.5

28.3

32 / 32

4 + earth

Page 146

Page 148: 2008 Product Catalogue

PUHY-EP400, 450YSHM-A

Side View > Front View >

PUHY-EP200, 300YHM-A

PUHY-EP500, 550YSHM-A

Cit

y M

ulti

Ran

ge 2

008

Y S

erie

s H

igh

CO

P (8

-26h

p)

Dimensions

Side View > Front View >

Side View > Front View >PUHY-EP600, 650YSHM-A

PUHY-EP200YHM-A schematic is the same as PUHY-P250, 300YHM-A on page 141PUHY-EP300YHM-A schematic is the same as PUHY-P350, 400, 450YHM-A on page 141

Page 147

Page 149: 2008 Product Catalogue

Heat Pump Outdoor Unit

Y Series High COP (28-36hp)

PUHY-EP700-900YSHM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

1000m max

165m max

40m max

50m max (40m max if outdoor installed below)

15m max

Improved for even higher efficiency

Technical Information

The City Multi Y series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

� Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil

� Choice of Branch Pipe or Header Pipe feeds to indoor units

� Energy-saving inverter driven outdoor compressor units with very low start currents

� No requirement for plant rooms or bulky service shafts

� Weight and size reduction compared to previous YGM-A models

� Improved pipe run of 165m, with a total system pipe length of 1000m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

Page 148

Y SERIES HIGH COP OUTDOOR UNIT 28-36hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

COP/EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PUHY-EP700YSHM-A

88.0

80.0

75.7

73.6

20.00

20.99

18.60

15.11

4.40 / 3.81

50

225 / 185 / 185

63

245 + 200 + 200

1220 + 920 + 920

760

1710

380-415v, 50Hz

3

8 / 8 / 8

30.9

32.4

32 / 20 / 20

4 + earth

PUHY-EP750YSHM-A

95.0

85.0

81.7

78.2

22.19

21.79

20.64

15.69

4.28 / 3.90

50

225 / 185 / 185

63

245 + 200 + 200

1220 + 920 + 920

760

1710

380-415v, 50Hz

3

8 / 8 / 8

34.3

33.6

32 / 32 / 20

4 + earth

PUHY-EP800YSHM-A

100.0

90.0

86.0

82.8

23.41

22.00

21.77

15.84

4.27 / 4.09

50

225 / 225 / 185

64

245 + 245 + 200

1220 + 1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8 / 8

36.1

34.0

32 / 32 / 20

4 + earth

PUHY-EP850YSHM-A

108.0

96.0

95.0

88.3

25.59

24.67

23.54

16.28

4.22 / 3.89

50

225 / 225 / 185

64

245 + 245 + 200

1220 + 1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8 / 8

39.5

38.1

32 / 32 / 32

4 + earth

PUHY-EP900YSHM-A

113.0

101.0

99.4

92.9

27.90

24.87

25.67

16.41

4.05 / 4.06

50

225 / 225 / 225

65

245 + 245 + 245

1220 +1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8 / 8

43.1

38.4

32 / 32 / 32

4 + earth

Page 150: 2008 Product Catalogue

Cit

y M

ulti

Ran

ge 2

008

Y S

erie

s H

igh

CO

P (2

8-36

hp)

PUHY-EP700, 750YSHM-A

PUHY-EP800, 850YSHM-A

Dimensions

Side View > Front View >

Side View > Front View >

Side View > Front View >

PUHY-EP900YSHM-A

Page 149

Page 151: 2008 Product Catalogue

WY SERIES HEAT SOURCE UNIT - 8-20hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

PQHY-P200YGM-A

25.0

22.4

4.69

4.79

13

46

272

990

550

1800

380-415v, 50Hz

3

8

7.2

7.4

20

4 + earth

PQHY-P250YGM-A

31.5

28.0

5.80

5.95

16

47

275

990

550

1800

380-415v, 50Hz

3

8

8.9

9.1

25

4 + earth

PQHY-P400YSGM-A

50.0

45.0

11.01

11.35

22

50

208 + 244

1980

550

1800

380-415v, 50Hz

3

8

17.0

17.5

40

4 + earth

PQHY-P500YSGM-A

63.0

56.0

13.60

15.06

24

53

208 + 248

1980

550

1800

380-415v, 50Hz

3

8

21.0

23.3

50

4 + earth

WY Series (8-20hp)Heat Pump, Water Cooled Condensing Unit

PQHY-P200-500Y(S)GM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

300m max

150m max

40m max

50m max (40m max if outdoor installed below)

15m max

Technical Information

The WY Series has all the benefits of the Y Series using water cooled condensingunits. It is also able to produce heat recovery via the water circuit between heat source units, making for a very economical system.

� High COPs possible thanks to increased efficiency and careful control of the system, allowing the largest operational water circuit temperature band ever

� Combining WY with waste heat energy provides unique application solutions

� Up to 24 indoor units can be connected to each condensing unit

� Condensing units can be situated indoors allowing greater design flexibility and no limitation on building size

� Single inverter compressor up to 20hp

� Improved pipe run of 150m with a total system pipe length of up to 300m

� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

� Now able to operate with closed loop ground source water temperatures, bore hole and slinky applications are now possible

Page 150

Page 152: 2008 Product Catalogue

PQHY-P200, 250YGM-A

PQHY-P400, 500YSGM-A

Upper View >

Front View >

Left Side View >

Upper View >

Front View >

Left Side View >

Cit

y M

ulti

Ran

ge 2

008

WY

Ser

ies

(8-2

0hp)

Dimensions

Page 151

Page 153: 2008 Product Catalogue

R2 Series Standard (10-16hp)Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

Improved for even higher efficiencyThroughout the year, many buildings require cooling in some areas and heating in others -even in adjacent rooms. The outstanding City Multi R2 system meets this requirement bydistributing surplus heat from cooling operations (and vice versa) to rooms where it is needed.This efficiency can result in energy savings of up to 30% over conventional systems.

� New higher efficiency inverter technology, with low start currents and wrap around coil for added efficiency

� Up to 40 indoor units connected to each outdoor unit

� Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than a 3 pipe equivalents

� Weight and size reduction compared to previous YGM-A models

� Improved pipe run of 165m with a total system pipe length of up to 600m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

Page 152

R2 SERIES STANDARD OUTDOOR UNIT 10-16hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

COP/EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PURY-P250YHM-A

31.5

28.0

28.7

26.6

7.83

7.73

7.75

4.79

4.02 / 3.62

25

185

57

235

920

760

1710

380-415v, 50Hz

3

8

12.1

11.9

32

4 + earth

PURY-P300YHM-A

37.5

33.5

33.0

31.5

9.58

9.25

9.29

6.85

3.91 / 3.62

30

185

59

240

920

760

1710

380-415v, 50Hz

3

8

14.8

14.2

32

4 + earth

PURY-P350YHM-A

45.0

40.0

39.6

37.6

12.47

12.47

12.10

9.23

3.60 / 3.20

35

225

60

265

1220

760

1710

380-415v, 50Hz

3

8

19.2

19.2

32

4 + earth

PURY-P400YHM-A

50.0

45.0

44.0

42.3

13.71

13.74

13.30

10.17

3.64 / 3.27

40

225

61

265

1220

760

1710

380-415v, 50Hz

3

8

21.1

21.2

40

4 + earth

Technical Information

Note: For piping restrictions for PURY-P250-400YHM-A please see page 158

Page 154: 2008 Product Catalogue

Cit

y M

ulti

Ran

ge 2

008

R2

Seri

es S

tand

ard

(10-

16hp

)

PURY-P250, 300YHM-A

PURY-P350, 400YHM-A

Upper View >

Upper View >

Dimensions

Front View >Side View >

Front View >Side View >

Page 153

Page 155: 2008 Product Catalogue

R2 Series Standard (20-32hp)Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

Improved for even higher efficiencyThroughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement bydistributing surplus heat from cooling operations (and vice versa) to rooms where it is needed.This efficiency can result in energy savings of up to 30% over conventional systems.

� New higher efficiency inverter technology, with low start currents and wrap around coil for added efficiency

� Up to 50 indoor units connected to each outdoor unit

� Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than a 3 pipe equivalents

� Weight and size reduction compared to previous YGM-A models

� Improved pipe run of 165m with a total system pipe length of up to 950m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

Page 154

Note: For piping restrictions for PURY-P500-800YSHM-A please see page 158

Technical Information

R2 SERIES STANDARD OUTDOOR UNIT 20-32hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

COP/EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PURY-P500YSHM-A

63.0

56.0

54.8

51.5

16.79

16.75

15.28

11.73

3.75 / 3.34

50

185 / 185

60

235 + 235

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

25.9

25.8

32 / 32

4 + earth

PURY-P550YSHM-A

69.0

63.0

60.0

58.0

18.81

18.68

17.12

13.08

3.66 / 3.37

50

185 / 185

61

240 + 235

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

29.0

28.8

32 / 32

4 + earth

PURY-P600YSHM-A

76.5

69.0

66.6

63.5

20.83

19.64

18.96

13.75

3.67 / 3.51

50

185 / 185

62

240 + 240

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

32.1

30.3

32 / 32

4 + earth

PURY-P650YSHM-A

81.5

73.0

70.9

67.2

22.55

22.80

20.52

15.96

3.61 / 3.20

50

225 / 185

62.5

265 + 240

1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8

34.8

35.2

32 / 32

4 + earth

PURY-P700YSHM-A

88.0

80.0

75.7

73.6

24.30

24.72

22.60

17.80

3.62 / 3.23

50

225 / 185

63

265 + 240

1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8

37.5

38.2

40 / 32

4 + earth

PURY-P750YSHM-A

95.0

85.0

81.7

78.2

26.36

27.86

24.51

20.06

3.60 / 3.05

50

225 / 225

63.5

265 + 265

1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

40.7

43.0

40 / 32

4 + earth

PURY-P800YSHM-A

100.0

90.0

86.0

82.8

27.64

29.75

25.71

21.42

3.61 / 3.02

50

225 / 225

64

265 + 265

1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

42.7

45.9

40 / 40

4 + earth

Page 156: 2008 Product Catalogue

Cit

y M

ulti

Ran

ge 2

008

R2

Seri

es S

tand

ard

(20-

32hp

)

PURY-P500, 550, 600YSHM-A

PURY-P650, 700YSHM-A

Dimensions

Side View > Front View >

Side View > Front View >

Side View > Front View >

PURY-P750, 800YSHM-A

Page 155

Page 157: 2008 Product Catalogue

R2 Series High COP (8-24hp)Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

Improved for even higher efficiencyThroughout the year, many buildings require cooling in some areas and heating inothers - even in adjacent rooms. The outstanding City Multi R2 system meets thisrequirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems.

� Highest ever COP’s / EER’s due to new high efficiency inverter technology and wrap around coil for added efficiency

� Up to 50 indoor units connected to each outdoor unit

� Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than a 3 pipe equivalents

� Weight and size reduction compared to previous YGM-A models

� Improved pipe run of 165m with a total system pipe length of up to 800m

� 100% inverter control with low start currents

� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

Note: For piping restrictions for PURY-EP200-600Y(S)HM-A please see page 158

Technical Information

R2 SERIES HIGH COP OUTDOOR UNIT 8-24hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

COP/EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PURY-EP200YHM-A

25.0

22.4

23.0

21.3

5.81

5.23

5.75

3.24

4.30 / 4.28

20

185

57

235

920

760

1710

380-415v, 50Hz

3

8

8.9

8.0

20

4 + earth

PURY-EP300YHM-A

37.5

33.5

33.0

31.5

9.37

8.33

9.09

6.16

4.00 / 4.02

30

225

60

265

1220

760

1710

380-415v, 50Hz

3

8

14.4

12.8

32

4 + earth

PURY-EP400YSHM-A

50.0

45.0

44.0

42.3

11.73

10.57

11.38

7.82

4.26 / 4.25

40

185 / 185

60

235 + 235

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

18.1

16.3

20 / 20

4 + earth

PURY-EP450YSHM-A

56.0

50.0

48.7

46.0

13.77

13.09

12.53

9.16

4.06 / 3.81

45

185 / 185

60

235 + 235

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

21.2

20.2

32 / 20

4 + earth

PURY-EP500YSHM-A

63.0

56.0

54.8

51.5

15.33

13.70

13.95

9.59

4.10 / 4.08

50

225 / 185

62

265 + 235

1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8

23.6

21.1

32 / 20

4 + earth

PURY-EP550YSHM-A

69.0

63.0

60.0

58.0

17.37

16.38

15.81

11.47

3.97 / 3.84

50

225 / 185

62

265 + 235

1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8

26.8

25.3

32 / 32

4 + earth

PURY-EP600YSHM-A

76.5

69.0

66.6

63.5

19.12

17.00

17.40

11.90

4.00 / 4.05

50

225 / 225

63

265 + 265

1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

29.5

26.2

32 / 32

4 + earth

Page 156

Page 158: 2008 Product Catalogue

Side View > Front View >

Side View > Front View >

Side View > Front View >

PURY-EP400, 450YSHM-A

PURY-EP200, 300YHM-A

PURY-EP500, 550YSHM-A

Cit

y M

ulti

Ran

ge 2

008

R2

Seri

es H

igh

CO

P (8

-24h

p)

Dimensions

PURY-EP600YSHM-A

PURY-EP200YHM-A schematic is the same as PURY-P250, 300YHM-A on page 153PURY-EP300YHM-A schematic is the same as PURY-P350, 400YHM-A on page 153

Page 157

Page 159: 2008 Product Catalogue

OUTDOOR MODEL MAX LENGTHTABLE 1: TOTAL PIPE LENGTHR2 SERIES PIPING RESTRICTIONS

GRAPH 1: TOTAL PIPING LENGTH RESTRICTIONS

P250, P300P350, P400, EP200, EP300P500, P550, EP400, EP450, EP500, EP550P600, P650, EP600P700, P750, P800

550m*1

600m*1

750m*1

800m*1

950m*1

*1 Please refer to Graph 1

1000

PURY-P700,750,800 YSHM-A

PURY-P600,650,800 YSHM-A, PURY-EP600YSHM-A

PURY-P500,550 YSHM-A, PURY-EP400,450,500,550 YSHM-A

PURY-P350,400 YHM-A, PURY-EP200,300 YHM-A

PURY-P250,300YHM-A

900

800

700

600

500

400

300

200

100

0

10 20 30 40 50 60 70 80 90 100 110

Tota

l Ext

ende

d Pi

pe L

engt

h (m

)

Distance Between Outdoor Unit and BC Controller (m)

R2 SERIES PIPING RESTRICTIONS

ITEM PIPE SECTION MAX LENGTH

R2 SERIES PIPING RESTRICTIONS

PIPING LENGTH (1 BC CONTROLLER, NO SUB BC CONTROLLER)

Total Piping LengthFurthest Piping LengthLength Between OU and BCLength Between Furthest IU and BCHeight Between OU and IU (OU above IU)Height Between OU and IU (OU below IU)Height Between IU and BCHeight Between IU and IU

A+B+a+b+c+dA+B+d

AB+dHH1

h1h2

(See Table 1)165m

110m*1

60m*2 (40m)50m40m15m15m

*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

R2 Series Piping Restrictions

Page 158

Page 160: 2008 Product Catalogue

Cit

y M

ulti

Ran

ge 2

008

R2

Seri

es P

ipin

g R

estr

ictio

ns

ITEM PIPE SECTION MAX LENGTH

R2 SERIES PIPING RESTRICTIONS

PIPING LENGTH (>1 BC CONTROLLER FOR 1 OUTDOOR UNIT)

Total Piping LengthFurthest Piping LengthLength Between OU and BCLength Between Furthest IU and BCHeight Between OU and IU (OU above IU)Height Between OU and IU (OU below IU)Height Between IU and BCHeight Between IU and IUHeight Between BC (Main or Sub) and BC (Sub)

A+B+C+D+E+a+b+c+d+e+fA+C+E+f

AB+d or C+D+e or C+E+f

HH1

h1h2h3

(See Table 1)165m

110m*1

60m*2 (40m)50m40m15m15m15m

*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

ITEM PIPE SECTION MAX LENGTH

R2 SERIES PIPING RESTRICTIONS

PIPING LENGTH (>1 BC CONTROLLER FOR 2 OUTDOOR UNITS)

Total Piping LengthFurthest Piping LengthLength Between OU and BCLength Between Furthest IU and BCHeight Between OU and IU (OU above IU)Height Between OU and IU (OU below IU)Height Between IU and BCHeight Between IU and IUHeight Between BC (Main or Sub) and BC (Sub)Length Between Main OU and Sub OUHeight Between Main OU and Sub OU

F+G+A+B+C+D+E+a+b+c+d+e+fF(G)+A+C+E+f

F(G)+AB+d or C+D+e or C+E+f

HH1

h1h2h3

F+G or Hh4

(See Table 1)165m

110m*1

60m*2 (40m)50m40m15m15m15m5m

0.1m

*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

Page 159

Page 161: 2008 Product Catalogue

WR2 SERIES HEAT SOURCE UNIT - 8-20hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

PQRY-P200YGM-A

25.0

22.4

4.69

4.79

15

46

263

990

550

1800

380-415v, 50Hz

3

8

7.2

7.4

20

4 + earth

PQRY-P250YGM-A

31.5

28.0

5.80

5.95

19

47

266

990

550

1800

380-415v, 50Hz

3

8

8.9

9.1

25

4 + earth

PQRY-P400YSGM-A

50.0

45.0

11.01

11.35

24

50

208 + 232

1980

550

1800

380-415v, 50Hz

3

8

17.0

17.5

40

4 + earth

PQRY-P500YSGM-A

63.0

56.0

13.60

15.06

24

53

208 + 236

1980

550

1800

380-415v, 50Hz

3

8

21.0

23.3

50

4 + earth

WR2 Series (8-20hp)Water Cooled Condensing UnitSimultaneous Heating and Cooling with Double Heat Recovery

PQRY-P200-500Y(S)GM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

BETWEEN OUTDOOR AND BC CONTROLLER (MASTER) - LENGTH

BETWEEN INDOOR AND BC CONTROLLER (MASTER/SLAVE) - LENGTH

BETWEEN INDOOR AND OUTDOOR - HEIGHT

BETWEEN INDOOR AND INDOOR - HEIGHT

BETWEEN INDOOR AND BC CONTROLLER (MASTER/SLAVE) - HEIGHT

BETWEEN INDOOR (MASTER) AND INDOOR (SLAVE) - HEIGHT

400m max*3 (300m)

150m max

110m max*4 (70m)

60m max*5 (40m)

50m max (40m)*1

15m max (10m)*2

15m max

15m max (10m)*2

Technical Information

The WR2 system has double heat recovery potential, making this system very economical.Not only does it produce heat recovery from indoor units on the same refrigerant circuit,it also produces heat recovery via the water circuit between heat source units.

� All the benefits of the R2 Series with water cooled condensing units, using a single inverter compressor

� High COPs possible thanks to increased efficiency and careful control of the system, allowing the largest operational water circuit temperature band ever

� Unique 2-pipe refrigerant circuit allows simultaneous heating and cooling plus heat recovery between indoor units as with the R2 system

� Total building heat recovery made possible by exchanging energy in both refrigerant and water circuits

� Combining WR2 with waste heat energy provides unique application solutions

� Condensing units can be situated indoors allowing greater design flexibilityand no limitation on building size

� Single inverter compressor up to 20hp

� Improved pipe run of 150m with a total system pipe length of up to 400m

� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

� Now able to operate with closed loop ground source water temperatures, bore hole and slinky applications are now possible

Page 160

*1 When O/U is below indoor *2 In case of P200, P250 indoor unit *3 Distance between outdoor unit and BC Controller is 70m or less *4 Total piping length is 300m or less *5 Height difference between the Master BC Controller and furthest indoor unit is zero

Page 162: 2008 Product Catalogue

PQRY-P200, 250YGM-A

PQRY-P400, 500YSGM-A

Upper View >

Front View >

Left Side View >

Upper View >

Front View >

Left Side View >

Cit

y M

ulti

Ran

ge 2

008

WR

2 Se

ries

(8-

20hp

)

Dimensions

Page 161

Page 163: 2008 Product Catalogue

Heat Pump Close Control System

PFD-P-VM-E (10/20hp)

PUHY-P-YHM-A / PQHY-P-YGM-A - OUTDOOR UNITSPFD-P-VM-E - INDOOR UNIT

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

AIRFLOW (m3/min)

EXTERNAL STATIC PRESSURE (Pa)

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A) Inverter / DOL

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

PFD-P250VM-E

31.5

28.0

29.1

26.6

0.93

2.5

2.5

2.15

2.15

160

120

22.2 (7/8”)

9.52 (3/8”)

59

380

1380

780

1950

380-415v, 50Hz

3

47

4.9

4.9

16

4 + earth

PFD-P500VM-E

63.0

56.0

55.4

51.5

0.93

5.0

5.0

4.3

4.3

320

120

28.58 (1 1/8”)

15.88 (5/8”)

63

520

1980

780

1950

380-415v, 50Hz

3

68

8.7

8.7

20

4 + earth

PUHY-P-YHM-A / PQHY-P-YGM-A Piping Restrictions

TOTAL PIPING LENGTH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

165m max (150m for PQHY)

50m max (40m max if outdoor installed below)

Technical Information

Mitsubishi Electric’s new Close Control System is specifically designed for computer rooms, laboratories etc, where a need for high sensible cooling and close control of temperature and humidity is required. Because of the need forclose control 24 hours a day, 365 days a year, a newly developed inverter driven compressor has been incorporatedinto the outdoor unit, maximising the energy efficiency of the PFD series. It is also able to be connected to a computer network using our G50 controller, in order to monitor and provide remote email alarms.

� High sensible cooling

� Newly developed inverter driven compressor

� Energy efficient with high COP’s

� Close control of temperature, ±1ºC

� Easy to install - no service space needed at the rear of the unit

� Optional third party humidifier available

� Quick recovery following power failure

� Return or discharge air temperature control

Page 162

PUHY-P250YHM-A

31.5

28.0

28.7

26.6

N/A

6.6

6.8

6.55

4.2

185

N/A

22.2 (7/8”)

9.52 (3/8”)

57

200

920

760

1710

380-415v, 50Hz

3

8

10.2

10.5

32

4 + earth

PUHY-P250YHM-A x2

63.0

56.0

54.8

51.5

N/A

6.6 / 6.6

6.8 / 6.8

6.55 / 6.55

4.2 / 4.2

185 / 185

N/A

28.58 (1 1/8”)

15.88 (5/8”)

57 / 57

200 + 200

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

10.2 / 10.2

10.5 / 10.5

32 / 32

4 + earth

PQHY-P250YGM-A x2

63.0

56.0

N/A

N/A

N/A

5.6 / 5.6

5.9 / 5.9

N/A

N/A

N/A

N/A

28.58 (1 1/8”)

15.88 (5/8”)

47 / 47

275 + 275

990 + 990

550

1800

380-415v, 50Hz

3

8 / 8

8.5 / 8.5

9.0 / 9.0

25 / 25

4 + earth

PQHY-P250YGM-A

31.5

28.0

N/A

N/A

N/A

5.6

5.9

N/A

N/A

N/A

N/A

22.2 (7/8”)

9.52 (3/8”)

47

275

990

550

1800

380-415v, 50Hz

3

8

8.5

9.0

25

4 + earth

Page 164: 2008 Product Catalogue

PFD-P250VM-E

PFD-P500VM-E

Upper View >

Front View >

Side View >

Upper View >

Front View >

Side View >

Cit

y M

ulti

Ran

ge 2

008

PFD

-P-V

M-E

(10

/20h

p)

Dimensions

Page 163

Page 165: 2008 Product Catalogue

PLFY-P-VBM-E2, 3 and 4-Way Blow Ceiling Cassette Indoor Unit

PLFY-P-VBM-E - INDOOR UNITMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

High Sensible Cooling (UK)

SHF (UK)

High Sensible (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

NOISE (dBA) Lo-Mi1-Mi2-Hi

WEIGHT (kg) (Grille)

DIMENSIONS (mm) Width (Grille)

Depth (Grille)

Height (Grille)

ELECTRICAL SUPPLY

PHASE

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

GRILLE MODEL REFERENCE

PLFY-P32VBM-E

4.0

3.6

3.7

3.2

2.6

0.84

0.96

0.02

0.03

11-12-13-14

27-28-29-31

22(6)

840(950)

840(950)

258(35)

220-240v, 50Hz

Single

0.14

0.22

6

3

PLP-6BA

PLFY-P50VBM-E

6.3

5.6

5.8

5.0

4.1

0.76

0.83

0.03

0.04

12-13-14-16

27-28-30-31

22(6)

840(950)

840(950)

258(35)

220-240v, 50Hz

Single

0.22

0.29

6

3

PLP-6BA

PLFY-P80VBM-E

10.0

9.0

9.2

8.0

6.5

0.73

0.78

0.06

0.07

16-18-20-22

30-32-35-37

23(6)

840(950)

840(950)

258(35)

220-240v, 50Hz

Single

0.43

0.51

6

3

PLP-6BA

PLFY-P125VBM-E

16.0

14.0

14.8

12.5

10.2

0.71

0.74

0.15

0.16

22-25-28-30

35-38-41-43

27(6)

840(950)

840(950)

298(35)

220-240v, 50Hz

Single

1.00

1.07

6

3

PLP-6BA

PLFY-P40VBM-E

5.0

4.5

4.6

4.0

3.3

0.83

0.91

0.03

0.04

12-13-14-16

27-28-30-31

22(6)

840(950)

840(950)

258(35)

220-240v, 50Hz

Single

0.22

0.29

6

3

PLP-6BA

PLFY-P63VBM-E

8.0

7.1

7.4

6.3

5.2

0.75

0.79

0.04

0.05

14-15-16-18

28-29-30-32

23(6)

840(950)

840(950)

258(35)

220-240v, 50Hz

Single

0.29

0.36

6

3

PLP-6BA

PLFY-P100VBM-E

12.5

11.2

11.6

10.0

8.1

0.73

0.79

0.14

0.15

21-24-27-29

34-37-39-41

27(6)

840(950)

840(950)

298(35)

220-240v, 50Hz

Single

0.94

1.00

6

3

PLP-6BA

Technical Information

Power cassettes offer 72 different airflow patterns, with the ability to handle a multitude of ceiling applications up to4.2 meters in height. The easy to install, slim unit is ideal for maintaining constant temperatures, thanks to adjustablevanes that allow users to precisely direct air where it’s needed.

The Mitsubishi Electric airflow control mechanism has been improved and uses wider vanes so that the unit reducesdrafts and smudging, whilst a high performance drain pump on the drain lift mechanism allows drain water to be lifted up to 850mm from the ceiling surface.

� Handy corner pocket design simplifies maintenance

� Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed

� Reduced draft air distribution, with independent vane control

� Drain pump as standard, 850mm from drain pan

� Filter lowering operation down to 4m (optional PLP-6BAJ grille required)

� Optional ‘I See Sensor’ for energy saving and smooth temperature control throughout the room

� For further information on the features of this cassette, please see page 60

Page 164

Page 166: 2008 Product Catalogue

PLFY-P32, 40, 50, 63, 80, 100, 125VBM-E

MODELS

PLFY-P32-80VBM-E

PLFY-P100-125VBM-E

A

241

281

B

258

298

Upper View >

Lower View >

Side View >

Cit

y M

ulti

Ran

ge 2

008

PLFY

-P-V

BM-E

Dimensions

Page 165

Page 167: 2008 Product Catalogue

PLFY-P-VCM-E

The compact size of this unit is ideal for 600x600mm ceilings and with a depth of 208mm, this lightweight unit makes installation a breeze. This unit also comes complete with a long life filter that will last for approximately 2,500 hours.

600x600 4-Way Blow Ceiling Cassette Indoor Unit

PLFY-P-VCM-E - INDOOR UNITMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

High Sensible Cooling (UK)

SHF (UK)

High Sensible (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

AIRFLOW (m3/min) Lo-Mi-Hi

NOISE (dBA) Lo-Mi-Hi

WEIGHT (kg) (Grille)

DIMENSIONS (mm) Width (Grille)

Depth (Grille)

Height (Grille)

ELECTRICAL SUPPLY

PHASE

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

GRILLE MODEL REFERENCE

PLFY-P20VCM-E

2.5

2.2

2.3

2.1

1.6

0.86

1.00

0.05

0.05

8-9-10

28-31-35

15.5(3)

570(650)

570(650)

208(20)

220-240v, 50Hz

Single

0.23

0.23

6

3

SLP-2AA

PLFY-P25VCM-E

3.2

2.8

3.0

2.6

2.0

0.81

0.90

0.05

0.05

8-9-10

28-31-37

15.5(3)

570(650)

570(650)

208(20)

220-240v, 50Hz

Single

0.23

0.23

6

3

SLP-2AA

PLFY-P32VCM-E

4.0

3.6

3.7

3.4

2.6

0.76

0.85

0.06

0.06

8-9-11

29-33-38

17(3)

570(650)

570(650)

208(20)

220-240v, 50Hz

Single

0.28

0.28

6

3

SLP-2AA

PLFY-P40VCM-E

5.0

4.5

4.6

4.3

3.3

0.70

0.76

0.06

0.06

8-9-11

30-34-39

17(3)

570(650)

570(650)

208(20)

220-240v, 50Hz

Single

0.28

0.28

6

3

SLP-2AA

Technical Information

� Compact size for handy installation and easy maintenance

� Only 208mm high

� Fresh air duct facility

Page 166

Page 168: 2008 Product Catalogue

PLFY-P20, 25, 32, 40VCM-E

Lower View >

Side View >

Cit

y M

ulti

Ran

ge 2

008

PLFY

-P-V

CM

-E

Dimensions

Page 167

Page 169: 2008 Product Catalogue

PLFY-P-VLMD-E2-Way Blow Ceiling Cassette Indoor Unit

PLFY-P-VLMD-E - INDOOR UNIT

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

High Sensible Cooling (UK)

SHF (UK)

High Sensible (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

NOISE (dBA) Lo-Mi1-Mi2-Hi

WEIGHT (kg) (Grille)

DIMENSIONS (mm) Width (Grille)

Depth (Grille)

Height (Grille)

ELECTRICAL SUPPLY

PHASE

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

GRILLE MODEL REFERENCE

PLFY-P20VLMD-E

2.5

2.2

2.3

2.1

1.6

0.81

0.94

0.065

0.072

6.5-8.0-9.5

27-30-33

23(6.5)

776(1080)

634(710)

290(20)

220-240v,

50Hz

Single

0.30

0.36

6

3

CMP-40VLW-B

PLFY-P25VLMD-E

3.2

2.8

3.0

2.6

2.0

0.77

0.85

0.065

0.072

6.5-8.0-9.5

27-30-33

23(6.5)

776(1080)

634(710)

290(20)

220-240v,

50Hz

Single

0.30

0.36

6

3

CMP-

40VLW-B

PLFY-P32VLMD-E

4.0

3.6

3.7

3.4

2.6

0.74

0.81

0.065

0.072

6.5-8.0-9.5

27-30-33

24(6.5)

776(1080)

634(710)

290(20)

220-240v,

50Hz

Single

0.30

0.36

6

3

CMP-40VLW-B

PLFY-P40VLMD-E

5.0

4.5

4.6

4.3

3.3

0.67

0.73

0.074

0.081

7.0-8.5-10.5

29-33-36

24(6.5)

776(1080)

634(710)

290(20)

220-240v,

50Hz

Single

0.34

0.40

6

3

CMP-40VLW-B

PLFY-P50VLMD-E

6.3

5.6

5.8

5.3

4.1

0.70

0.73

0.075

0.082

9.0-11.0-12.5

31-34-37

27(7.5)

946(1250)

634(710)

290(20)

220-240v,

50Hz

Single

0.35

0.41

6

3

CMP-63VLW-B

PLFY-P63VLMD-E

8.0

7.1

7.4

6.7

5.2

0.72

0.77

0.094

0.101

10.0-13.0-15.5

32-37-39

28(7.5)

946(1250)

634(710)

290(20)

220-240v,

50Hz

Single

0.43

0.49

6

3

CMP-63VLW-B

PLFY-P80VLMD-E

10.0

9.0

9.2

8.5

6.5

0.71

0.77

0.140

0.147

15.5-18.5-22.0

33-36-39

44(12.5)

1446(1750)

634(710)

290(20)

220-240v,

50Hz

Single

0.66

0.72

6

3

CMP-100VLW-B

PLFY-P100VLMD-E

12.5

11.2

11.6

10.6

8.1

0.73

0.79

0.150

0.157

17.5-21.0-25.0

36-39-42

47(12.5)

1446(1750)

634(710)

290(20)

220-240v,

50Hz

Single

0.69

0.75

6

3

CMP-100VLW-B

PLFY-P125VLMD-E

16.0

14.0

14.8

13.2

10.2

0.73

0.80

0.27

0.28

24-27-30-33

40-42-44-46

56(13)

1708(2010)

606(710)

290(20)

220-240v,

50Hz

Single

1.33

1.35

6

3

CMP-125VLW-B

Technical Information

The PLFY-P-VLMD-E cassette unit fits into the space in a suspended ceiling to provideheating or cooling. This new unit has been redesigned with lower unit height and lower noise levels.

� Light unit for ease of installation

� Terminal block on outside of unit for easy wiring

� Drain lift-pump mechanism as standard

� Newly designed decoration panel with air flow switching and swing functions as standard

Page 168

Page 170: 2008 Product Catalogue

PLFY-P20, 25, 32, 40, 50, 63, 80, 100VLMD-E

PLFY-P125VLMD-E

Front View > Upper View >

Lower View >

Side View > Upper View >

Side View >

Rear View > Lower View >

Cit

y M

ulti

Ran

ge 2

008

PLFY

-P-V

LMD

-E

Dimensions

Page 169

Page 171: 2008 Product Catalogue

PMFY-P-VBM-E1-Way Blow Ceiling Cassette Indoor Unit

PMFY-P-VBM-E - INDOOR UNITMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

High Sensible Cooling (UK)

SHF (UK)

High Sensible (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

NOISE (dBA) Lo-Mi1-Mi2-Hi

WEIGHT (kg) (Grille)

DIMENSIONS (mm) Width (Grille)

Depth (Grille)

Height (Grille)

ELECTRICAL SUPPLY

PHASE

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

GRILLE MODEL REFERENCE

PMFY-P20VBM-E

2.5

2.2

2.3

2.1

1.6

0.81

0.94

0.042

0.042

6.5-7.2-8.0-8.7

27-30-33-35

14(3)

812(1000)

395(470)

230(30)

220-240v, 50Hz

Single

0.20

0.20

6

3

PMP-40BM

PMFY-P25VBM-E

3.2

2.8

3.0

2.6

2.0

0.77

0.90

0.044

0.044

7.3-8.0-8.6-9.3

32-34-36-37

14(3)

812(1000)

395(470)

230(30)

220-240v, 50Hz

Single

0.21

0.21

6

3

PMP-40BM

PMFY-P32VBM-E

4.0

3.6

3.7

3.4

2.6

0.71

0.77

0.044

0.044

7.3-8.0-8.6-9.3

32-34-36-37

14(3)

812(1000)

395(470)

230(30)

220-240v, 50Hz

Single

0.21

0.21

6

3

PMP-40BM

PMFY-P40VBM-E

5.0

4.5

4.6

4.3

3.3

0.70

0.76

0.054

0.054

7.7-8.7-9.7-10.7

33-35-37-39

14(3)

812(1000)

395(470)

230(30)

220-240v, 50Hz

Single

0.26

0.26

6

3

PMP-40BM

Technical Information

Utilising a compact and lightweight body, the unit is perfect for applications where ceiling space is limited. A total body weight of 14kg makes it one of the lightest available, latest fan technology also makes it one of the quietest.

� Compact size for handy installation and easy maintenance

� Newly developed airflow control technology reduces noise levels to only 27dBA

� Drain lift pump mechanism allows the drain to be positioned anywhere up to 600mm from the ceiling’s surface

� Only 230mm high

� Fresh air duct facility

Page 170

Page 172: 2008 Product Catalogue

Lower View >

Side View >

Upper View >

Front View >

PMFY-P20, 25, 32, 40VBM-E

Cit

y M

ulti

Ran

ge 2

008

PMFY

-P-V

BM-E

Dimensions

Page 171

Page 173: 2008 Product Catalogue

PEFY-P-VMS1-EUltra Thin Ceiling Concealed Ducted Indoor Unit

The ultra thin ceiling concealed ducted indoor unit offers increased flexibility and is particularlysuitable for places where low noise operation is desired from a slimline body.

� Ultra thin body - height of only 200mm & width of only 790mm (P15-32)

� Extremely quiet operation - as low as 22dBA

� Cooling operation set temperature can be set down to 14°C db

� Static pressure of 5-50Pa

� Now available in a size 15, ideal for hotel rooms

PEFY-P-VMS1-E - INDOOR UNITMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

High Sensible Cooling (UK)

SHF (UK)

High Sensible (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

AIRFLOW (m3/min) Lo-Mi-Hi

EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Mi2-Hi

NOISE (dBA) (5Pa) Lo-Mi-Hi

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

PEFY-P15VMS1-E

1.9

1.7

1.8

1.5

1.2

0.93

1.00

0.03

0.05

5.0-6.0-7.0

5-15-35-50

22-24-28

19

790

700

200

220-240v, 50Hz

Single

0.31

0.42

6

3

PEFY-P25VMS1-E

3.2

2.8

3.0

2.5

2.0

0.84

0.90

0.04

0.06

5.5-7.0-9.0

5-15-35-50

24-26-30

19

790

700

200

220-240v, 50Hz

Single

0.39

0.50

6

3

PEFY-P40VMS1-E

5.0

4.5

4.6

4.0

3.3

0.75

0.82

0.05

0.07

8.0-9.5-11.0

5-15-35-50

28-30-33

24

990

700

200

220-240v, 50Hz

Single

0.45

0.56

6

3

PEFY-P63VMS1-E

8.0

7.1

7.4

6.3

5.2

0.75

0.79

0.07

0.09

12.0-14.0-16.5

5-15-35-50

30-33-36

28

1190

700

200

220-240v, 50Hz

Single

0.61

0.72

6

3

PEFY-P20VMS1-E

2.5

2.2

2.3

2.0

1.6

0.85

1.00

0.03

0.05

5.5-6.5-8.0

5-15-35-50

23-25-29

19

790

700

200

220-240v, 50Hz

Single

0.36

0.47

6

3

PEFY-P32VMS1-E

4.0

3.6

3.7

3.2

2.6

0.78

0.85

0.05

0.07

6.0-8.0-10.0

5-15-35-50

24-27-32

20

790

700

200

220-240v, 50Hz

Single

0.39

0.50

6

3

PEFY-P50VMS1-E

6.3

5.6

5.8

5.0

4.1

0.74

0.78

0.07

0.09

9.5-11.0-13.0

5-15-35-50

30-32-35

24

990

700

200

220-240v, 50Hz

Single

0.56

0.67

6

3

Technical Information

Page 172

Page 174: 2008 Product Catalogue

PEFY-P15, 20, 25, 32, 40, 50, 63 VMS1-E

A BPEFY-P15-32VMS1-E 700 752

PEFY-P40-50VMS1-E 900 952

C798

998

D660

860

E7

9

F600

800

PEFY-P63VMS1-E 1100 1152 1198 1060 11 1000

Model

Side View >

Front View >

Upper View >

Cit

y M

ulti

Ran

ge 2

008

PEFY

-P-V

MS1

-E

Dimensions

Page 173

Page 175: 2008 Product Catalogue

PEFY-P-VMM-ECeiling Concealed Ducted Indoor Unit

PEFY-P-VMM-E - INDOOR UNITMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

High Sensible Cooling (UK)

SHF (UK)

High Sensible (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

AIRFLOW (m3/min) Lo-Mi-Hi

EXTERNAL STATIC PRESSURE (Pa) - Lo-Mi-Hi

NOISE (dBA) Lo-Mi-Hi

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

PEFY-P20VMM-E

2.5

2.2

2.3

2.1

1.6

0.86

0.94

0.15

0.15

6.0-7.2-8.5

30-50-100

27-30-32

27

815

700

295

220-240v,

50Hz

Single

0.73

0.73

6

3

PEFY-P25VMM-E

3.2

2.8

3.0

2.6

2.0

0.77

0.85

0.15

0.15

6.0-7.2-8.5

30-50-100

27-30-32

27

815

700

295

220-240v,

50Hz

Single

0.73

0.73

6

3

PEFY-P32VMM-E

4.0

3.6

3.7

3.4

2.6

0.76

0.85

0.17

0.17

7.5-9.0-10.5

30-50-100

28-32-35

27

815

700

295

220-240v,

50Hz

Single

0.81

0.81

6

3

PEFY-P40VMM-E

5.0

4.5

4.6

4.3

3.3

0.77

0.85

0.19

0.19

10-12-14

30-50-100

31-34-37

33

935

700

295

220-240v,

50Hz

Single

0.92

0.92

6

3

PEFY-P50VMM-E

6.3

5.6

5.8

5.3

4.1

0.75

0.83

0.20

0.20

12.0-14.5-17.0

30-50-100

31-35-38

33

935

700

295

220-240v,

50Hz

Single

0.98

0.98

6

3

PEFY-P63VMM-E

8.0

7.1

7.4

6.7

5.2

0.75

0.81

0.22

0.22

13.5-16.2-19.0

30-50-100

31-35-38

42

1175

700

295

220-240v,

50Hz

Single

1.07

1.07

6

3

PEFY-P80VMM-E

10.0

9.0

9.2

8.5

6.5

0.72

0.78

0.25

0.25

14.5-18.0-21.0

30-50-100

32-36-39

42

1175

700

295

220-240v,

50Hz

Single

1.15

1.15

6

3

PEFY-P100VMM-E

12.5

11.2

11.6

10.6

8.1

0.78

0.88

0.29

0.29

23-33

50-130

40-44

62

1415

740

325

220-240v,

50Hz

Single

1.34

1.34

6

3

PEFY-P125VMM-E

16.0

14.0

14.8

13.2

10.2

0.77

0.85

0.40

0.40

28-40

50-130

42-45

65

1415

740

325

220-240v,

50Hz

Single

1.90

1.90

6

3

Technical Information

The PEFY-P-VMM-E ducted indoor unit is concealed within the ceiling space to allow unobtrusive air conditioning. Flexibility of duct layout allows air flow patterns to be arranged to suit any application.

� Reduced noise levels thanks to the use of a newlydesigned centrifugal fan - as low as 27dBA

� Drain lift-pump (option), 550mm of lift

� Complete flexibility in air conditioning design

� Cooling operation set temperature can be set down to 14ºC db

Page 174

Page 176: 2008 Product Catalogue

PEFY-P20, 25, 32, 40, 50, 63, 80VMM-E

PEFY-P100, 125VMM-E

1252

1252

1252

360

360

360370

370

370

1310

1284

Upper View >

Side View >

Upper View >

Front View >

Side View > Front View >

A BPEFY-P20-32VMM-E 652 245

PEFY-P40-50VMM-E 772 305PEFY-P63-80VMM-E 1012 280

C-

-290

D710

8301070

E684

8041044

Model

Cit

y M

ulti

Ran

ge 2

008

PEFY

-P-V

MM

-E

Dimensions

Page 175

Page 177: 2008 Product Catalogue

PEFY-P-VMH-EHigh Static Pressure Ceiling Concealed Ducted Indoor Unit

PEFY-P-VMH-E - INDOOR UNITMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

High Sensible Cooling (UK)

SHF (UK)

High Sensible (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

AIRFLOW (m3/min) Lo-Hi

EXTERNAL STATIC PRESSURE (Pa) - Lo-Mi-Hi

NOISE (dBA) Lo-Hi

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

PEFY-P80VMH-E

10.0

9.0

9.2

8.5

6.5

0.74

0.83

0.32

0.32

18-25

100-150-200

38-43

50

1000

900

380

220-240v,

50Hz

Single

1.47

1.47

6

3

PEFY-P100VMH-E

12.5

11.2

11.6

10.6

8.1

0.80

0.91

0.48

0.48

26.5-38.0

100-150-200

38-44

70

1200

900

380

220-240v,

50Hz

Single

2.34

2.34

6

3

PEFY-P125VMH-E

16.0

14.0

14.8

13.2

10.2

0.74

0.81

0.48

0.48

26.5-38.0

100-150-200

38-44

70

1200

900

380

220-240v,

50Hz

Single

2.34

2.34

6

3

PEFY-P140VMH-E

18.0

16.0

16.6

15.1

11.6

0.74

0.82

0.48

0.48

28-40

100-150-200

38-44

70

1200

900

380

220-240v,

50Hz

Single

2.35

2.35

6

3

Technical Information

With improved design flexibility as a result of increased external static pressure, the PEFY-P-VMH-Eallows authentic duct air conditioning within the strictest aesthetic confines.

� External static pressure of 200Pa

� Greater flexibility for duct extension, branching air outlet configuration

� Reduced noise levels thanks to the use of newly designed centrifugal fan

� Duct can be connected to intake side

� Drain lift-pump (option) 550mm of lift

� Cooling operation set temperature can be set down to 14ºC db

Page 176

Page 178: 2008 Product Catalogue

PEFY-P80, 100, 125, 140VMH-E

Side View >

Upper View >

Cit

y M

ulti

Ran

ge 2

008

PEFY

-P-V

MH

-E

Dimensions

Page 177

Page 179: 2008 Product Catalogue

PCFY-P-VGM-ECeiling Suspended Indoor Unit

PCFY-P-VGM-E - INDOOR UNITMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

High Sensible Cooling (UK)

SHF (UK)

High Sensible (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

NOISE (dBA) Lo-Mi1-Mi2-Hi

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

PCFY-P40VGM-E

5.0

4.5

4.6

4.3

3.3

0.72

0.79

0.10

0.10

8-10-11-12

29-33-36-38

27

1000

680

210

220-240v, 50Hz

Single

0.46

0.46

6

3

PCFY-P63VGM-E

8.0

7.1

7.4

6.7

5.2

0.72

0.79

0.13

0.13

12-14-16-18

32-34-37-39

34

1310

680

210

220-240v, 50Hz

Single

0.60

0.60

6

3

PCFY-P100VGM-E

12.5

11.2

11.6

10.6

8.1

0.71

0.77

0.16

0.16

18-20-23-25

36-38-41-43

37

1310

680

270

220-240v, 50Hz

Single

0.73

0.73

6

3

PCFY-P125VGM-E

16.0

14.0

14.8

13.2

10.2

0.70

0.76

0.24

0.24

26-28-32-35

37-39-42-44

43

1620

680

270

220-240v, 50Hz

Single

1.10

1.10

6

3

Technical Information

Designed for ultra-quiet operation and easy maintenance, the unit provides comfor table air conditioning for a wide range of applications where floor or wall space cannot be used practically.

� Indoor unit designed for direct ceiling suspension

� Flush to wall installation for concealment of service connections

� Drain piping can be connected from left or right

Page 178

Page 180: 2008 Product Catalogue

PCFY-P40, 63, 100, 125VGM-E

Lower View >

Upper View >

Front View >

Cit

y M

ulti

Ran

ge 2

008

PCFY

-P-V

GM

-E

Dimensions

Page 179

Page 181: 2008 Product Catalogue

PKFY-P-VBM-E/VGM-E/VFM-EWall Mounted Indoor Units

PKFY-P-VBM-E / VGM-E / VFM-E - INDOOR UNITMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

High Sensible Cooling (UK)

SHF (UK)

High Sensible (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

NOISE (dBA) Lo-Mi1-Mi2-Hi

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

PKFY-P20VBM-E

2.5

2.2

2.3

2.1

1.6

0.71

0.75

0.04

0.04

4.9-5.2-5.6-5.9

29-31-34-36

10

815

225

295

220-240v, 50Hz

Single

0.20

0.20

6

3

PKFY-P25VBM-E

3.2

2.8

3.0

2.6

2.0

0.73

0.80

0.04

0.04

4.9-5.2-5.6-5.9

29-31-34-36

10

815

225

295

220-240v, 50Hz

Single

0.20

0.20

6

3

PKFY-P32VGM-E

4.0

3.6

3.7

3.4

2.6

0.79

0.88

0.07

0.07

8.0-9.5-10.5-11.5

33-36-38-41

16

990

235

340

220-240v, 50Hz

Single

0.32

0.32

6

3

PKFY-P40VGM-E

5.0

4.5

4.6

4.3

3.3

0.74

0.82

0.07

0.07

8.0-9.5-10.5-11.5

33-36-38-41

16

990

235

340

220-240v, 50Hz

Single

0.32

0.32

6

3

PKFY-P63VFM-E

8.0

7.1

7.4

6.7

5.2

0.78

0.85

0.12

0.12

15-20

39-45

24

1400

235

340

220-240v, 50Hz

Single

0.55

0.55

6

3

PKFY-P50VGM-E

6.3

5.6

5.8

5.3

4.1

0.72

0.78

0.07

0.07

9-10-11-12

34-37-40-43

16

990

235

340

220-240v, 50Hz

Single

0.32

0.32

6

3

Technical Information

An elegant design combined with compact dimensions and quiet operationmake the PKFY-P an ideal unit choice. Noise levels are significantly reducedthanks to a unique airflow passage design that not only makes the unit one of the quietest in the industry, but also suppresses condensation and prevents mixing with secondary air.

� Compact design - only 815mm wide (VBM-E)

� Front grille opening for easy cleaning

� Front power supply for easy wiring after installation

� 5-way piping provides more flexibility in selection of installation sites

Page 180

Page 182: 2008 Product Catalogue

PKFY-P20, 25VBM-E

PKFY-P32, 40, 50VGM-E

Right Side View >Front View >

Right Side View >Front View >

PKFY-P63VFM-E

Right Side View >Front View >

Cit

y M

ulti

Ran

ge 2

008

PKFY

-P-V

BM-E

/ PK

FY-P

-VG

M-E

/ PK

FY-P

-VFM

-E

Dimensions

Page 181

Page 183: 2008 Product Catalogue

PFFY-P-VLRM-EFloor Standing Concealed Indoor Unit

PFFY-P-VLRM-E - INDOOR UNITMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

High Sensible Cooling (UK)

SHF (UK)

High Sensible (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

AIRFLOW (m3/min) Lo-Hi

NOISE (dBA) Lo-Hi

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

PFFY-P20VLRM-E

2.5

2.2

2.3

2.1

1.7

0.90

1.00

0.04

0.04

5.5-6.5

34-40

18.5

886

220

639

220-240v, 50Hz

Single

0.19

0.19

6

3

PFFY-P25VLRM-E

3.2

2.8

3.0

2.6

2.0

0.81

0.95

0.04

0.04

5.5-6.5

34-40

18.5

886

220

639

220-240v, 50Hz

Single

0.19

0.19

6

3

PFFY-P32VLRM-E

4.0

3.6

3.7

3.4

2.6

0.74

0.81

0.06

0.06

7-9

35-40

20

1006

220

639

220-240v, 50Hz

Single

0.29

0.29

6

3

PFFY-P40VLRM-E

5.0

4.5

4.6

4.3

3.3

0.72

0.79

0.065

0.065

9-11

38-43

21

1006

220

639

220-240v, 50Hz

Single

0.32

0.32

6

3

PFFY-P50VLRM-E

6.3

5.6

5.8

5.3

4.1

0.74

0.80

0.085

0.085

12-14

38-43

25

1246

220

639

220-240v, 50Hz

Single

0.40

0.40

6

3

PFFY-P63VLRM-E

8.0

7.1

7.4

6.7

5.2

0.73

0.79

0.10

0.10

12-15.5

40-46

27

1246

220

639

220-240v, 50Hz

Single

0.46

0.46

6

3

A compact concealed unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install and at only 220mm deep offers an unobtrusive method of delivering highly efficient air-conditioning performance.

� Concealed unit for hidden installation

� Ideal for perimeter refurbishments

� Cooling operation set temperature can be set down to 14ºC db

Technical Information

Page 182

Page 184: 2008 Product Catalogue

PFFY-P20, 25, 32, 40, 50, 63VLRM-E

Side View >

Upper View >

Front View >

Cit

y M

ulti

Ran

ge 2

008

PFFY

-P-V

LRM

-E

Dimensions

Page 183

Page 185: 2008 Product Catalogue

PFFY-P-VLRMM-EFloor Standing Concealed Indoor Unit

A compact concealed unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install and at only 220mm deep offers an unobtrusive method of delivering highly efficient air-conditioning performance.

PFFY-P-VLRMM-E - INDOOR UNIT

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

High Sensible Cooling (UK)

SHF (UK)

High Sensible (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

AIRFLOW (m3/min) Lo-Mi-Hi

EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Hi

NOISE (dBA) (20Pa) Lo-Mi-Hi

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

PFFY-P20VLRMM-E

2.5

2.2

2.3

2.0

1.6

0.80

0.88

0.04

0.04

4.5-5.5-6.5

20-40-60

31-36-40

18.5

886

220

639

220-240v, 50Hz

Single

0.34

0.34

6

3

PFFY-P32VLRMM-E

4.0

3.6

3.7

3.2

2.6

0.75

0.81

0.04

0.04

6.5-7.5-9

20-40-60

27-32-37

20

1006

220

639

220-240v, 50Hz

Single

0.38

0.38

6

3

PFFY-P50VLRMM-E

6.3

5.6

5.8

5.0

4.1

0.76

0.80

0.05

0.05

10-12-14

20-40-60

32-37-41

25

1246

220

639

220-240v, 50Hz

Single

0.48

0.48

6

3

PFFY-P25VLRMM-E

3.2

2.8

3.0

2.5

2.0

0.76

0.80

0.04

0.04

4.5-5.5-6.5

20-40-60

31-36-40

18.5

886

220

639

220-240v, 50Hz

Single

0.34

0.34

6

3

PFFY-P40VLRMM-E

5.0

4.5

4.6

4.0

3.3

0.75

0.79

0.05

0.05

8-9.5-11

20-40-60

30-36-40

21

1006

220

639

220-240v, 50Hz

Single

0.43

0.43

6

3

PFFY-P63VLRMM-E

8.0

7.1

7.4

6.3

5.2

0.73

0.79

0.07

0.07

11-13-15.5

20-40-60

35-40-44

27

1246

220

639

220-240v, 50Hz

Single

0.59

0.59

6

3

Technical Information

Page 184

� Reduced noise levels compared to the PFFY-P-VLRM-E version

� Cooling operation set temperature can be set down to 14ºC db

� Static pressure. The new unit has 3 static pressure settings- 20/40/60Pa ideal for ducting in the perimeter zone

� Concealed unit for hidden installation. The unit can be hiddenbehind a wardrobe in a hotel, then ducted above and below the wardrobe doors. This offers lower noise, less disruption and a low visual impact

Page 186: 2008 Product Catalogue

PFFY-P20, 25, 32, 40, 50, 63VLRMM-E

Side View >

Upper View >

Front View >

Cit

y M

ulti

Ran

ge 2

008

PFFY

-P-V

LRM

M-E

Dimensions

Page 185

Page 187: 2008 Product Catalogue

PFFY-P-VLEM-EFloor Standing Exposed Indoor Unit

PFFY-P-VLEM-E - INDOOR UNITMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

High Sensible Cooling (UK)

SHF (UK)

High Sensible (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

AIRFLOW (m3/min) Lo-Hi

NOISE (dBA) Lo-Hi

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

PFFY-P20VLEM-E

2.5

2.2

2.3

2.1

1.7

0.90

1.00

0.04

0.04

5.5-6.5

34-40

23

1050

220

630

220-240v, 50Hz

Single

0.19

0.19

6

3

PFFY-P25VLEM-E

3.2

2.8

3.0

2.6

2.0

0.81

0.95

0.04

0.04

5.5-6.5

34-40

23

1050

220

630

220-240v, 50Hz

Single

0.19

0.19

6

3

PFFY-P32VLEM-E

4.0

3.6

3.7

3.4

2.6

0.74

0.81

0.06

0.06

7-9

35-40

25

1170

220

630

220-240v, 50Hz

Single

0.29

0.29

6

3

PFFY-P40VLEM-E

5.0

4.5

4.6

4.3

3.3

0.72

0.79

0.065

0.065

9-11

38-43

26

1170

220

630

220-240v, 50Hz

Single

0.32

0.32

6

3

PFFY-P50VLEM-E

6.3

5.6

5.8

5.3

4.1

0.74

0.80

0.085

0.085

12-14

38-43

30

1410

220

630

220-240v, 50Hz

Single

0.40

0.40

6

3

PFFY-P63VLEM-E

8.0

7.1

7.4

6.7

5.2

0.73

0.79

0.10

0.10

12-15.5

40-46

32

1410

220

630

220-240v, 50Hz

Single

0.46

0.46

6

3

A compact cased unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install, and at only 220mmdeep offers an unobtrusive method of delivering a highly efficient air-conditioning performance.

� Remote controller can be incorporated into the main unit

� Cooling operation set temperature can be set down to 14ºC db

Technical Information

Page 186

Page 188: 2008 Product Catalogue

PFFY-P20,25,32,40,50,63VLEM-E

Side View >

Upper View >

Front View >

Cit

y M

ulti

Ran

ge 2

008

PFFY

-P-V

LEM

-E

Dimensions

Page 187

Page 189: 2008 Product Catalogue

PFFY-P-VKM-EFloor Standing Exposed Indoor Unit

PFFY-P-VKM-E - INDOOR UNITMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

High Sensible Cooling (UK)

SHF (UK)

High Sensible (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

NOISE (dBA) Lo-Mi1-Mi2-Hi

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

PFFY-P20VKM-E

2.5

2.2

2.3

2.1

1.6

0.81

0.88

0.025

0.025

5.9-6.8-7.6-8.7

27-31-34-37

15

700

200

600

220-240v, 50Hz

Single

0.20

0.20

6

3

PFFY-P25VKM-E

3.2

2.8

3.0

2.6

2.0

0.77

0.85

0.025

0.025

6.1-7.0-8.0-9.1

28-32-35-38

15

700

200

600

220-240v, 50Hz

Single

0.20

0.20

6

3

PFFY-P32VKM-E

4.0

3.6

3.7

3.4

2.6

0.71

0.77

0.025

0.025

6.1-7.0-8.0-9.1

28-32-35-38

15

700

200

600

220-240v, 50Hz

Single

0.20

0.20

6

3

PFFY-P40VKM-E

5.0

4.5

4.6

4.3

3.3

0.70

0.76

0.028

0.028

8.0-9.0-9.5-10.7

35-38-42-44

15

700

200

600

220-240v, 50Hz

Single

0.24

0.24

6

3

The PFFY-P-VKM-E series is extremely versatile and is designed for wall attached installation at floor level. The auto swing vane provides a more natural and comfortable airflow throughout the room and the lightweight, compact design makes installation easy.

� Pure white, slimline design

� Upper and lower vanes for optimum, powerful and efficient air distribution

Technical Information

Page 188

Page 190: 2008 Product Catalogue

PFFY-P20,25,32,40VKM-E

Front View >

Upper View >

Side View >C

ity

Mul

tiR

ange

200

8PF

FY-P

-VK

M-E

Dimensions

Page 189

Page 191: 2008 Product Catalogue

OUTDOOR AIR PROCESSING INDOOR UNITMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

POWER INPUT (kW)

AIRFLOW (m3/h) Lo-Hi

NOISE (dBA) Lo-Hi

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

RUNNING CURRENT (A) Lo-Hi

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

GUF-50RD3

6.42 (2.25)

5.29 (1.66)

5.93 (2.08)

5.03 (1.58)

0.265

400-500

29.5-34.5

54

1016

1288

317

220-240v, 50Hz

Single

0.70-1.15

6

3

GUF-100RD3

13.00 (4.70)

10.81 (3.49)

12.01 (4.34)

10.27 (3.32)

0.505

800-1000

34-39

92

1231

1580

398

220-240v, 50Hz

Single

1.73-2.20

6

3

GUF-50RD3 & GUF100RD3Lossnay Outdoor Air Processing Indoor Unit

Attention

1. Nominal Condition: Cooling/Heating capacity indicates the value of operation under the following air condition and above air volume.Cooling: Indoor 27ºC DB/19.5ºC WB, Outdoor 35ºC DB/24ºC WB.Heating: Indoor 21ºC DB/14.6ºC WB, Outdoor 7ºC DB/6ºC WB.

2. UK Condition:Summer: Indoor 21ºC, Outdoor 27ºCWinter : Indoor 21ºC, Outdoor -1ºCWB

3. The figures in ( ) indicates the heat recovery at Lossnay core.

4. The current, input and efficiency are based on the above air volume.

5. The air nozzle noise (45º angle 1.5m ahead) is about 6dB greater than the indicated value. (High notch).

6. Specifications may be subject to change without notice.

The GUF-50RD3 and GUF-100RD3 outdoor air processing units can be used with any of the extensive range of City Multi indoor units to provide ventilation, dust removal, humidification and heat recovery.

� A combination of a Lossnay & City Multi indoor in a single unit

� Air temperature in any room can be adjusted to the desired temperature via this unit which is used as an indoor unit of the City Multi air conditioning system

� The ventilating and air conditioning functions are integrated in a single unit, saving space and installation costs

� Heat recovery helps to save energy - a benefit that’s not only good for the environment, but also great for cutting energy costs

� Free cooling is also available should outdoor conditions be suitable

Technical Information

Page 190

Page 192: 2008 Product Catalogue

GUF-50/100RD3

Side View >

Upper View >

Front View >C

ity

Mul

tiR

ange

200

8G

UF-

50R

D3

and

GU

F100

RD

3

Dimensions

Page 191

Page 193: 2008 Product Catalogue

PQFY-P

PQFY-P140

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

PIPE SIZE mm(in) Gas Refrigerant

Liquid Refrigerant

Water

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

MAINS CABLE No. Cores

PQFY-P140

14.0

15.88 (5/8”)

9.52 (3/8”)

22

32

500

410

560

220-240v, 50Hz

Single

3

PQFY-P250

25.0

19.05 (3/4”)

9.52 (3/8”)

28

50

610

510

560

220-240v, 50Hz

Single

3

PQFY-PVRF Heat Pump Boiler

Flow RatePressure Drop

l/s

kPA

0.38

11.72

0.45

15.86

0.53

20.69

0.61

25.51

0.68

30.34

0.76

36.54

0.83

42.75

PQFY-P250

Flow RatePressure Drop

l/s

kPA

0.61

14.48

0.76

20.69

0.91

27.58

1.06

35.16

1.21

44.13

1.36

53.09

1.52

62.06

Note: The water flow rate can be above or below these values, but no pressure drop operating data can be provided.

It is well known in the air conditioning industry that heat pumps are proven to provide highly efficient cooling. However,in line with other forward-thinking countries, such as Sweden and Switzerland, Mitsubishi Electric have now designed aheat pump boiler to provide heating and hot water, suitable for underfloor heating or swimming pools. Heat pumptechnology is largely untapped and offers great potential with incredible design flexibility, excellent use of energy andgreatly reduced CO2 emissions.

The cooling operation of an air conditioning system that effectively extracts heat from a space, will normally be achieved atbetween 3.5 to 4.0 COP. This in itself is an efficient system. However, by recovering that heat and using it to heat up waterthe efficiency of the system increases dramatically to over 6.0 COP. Without the use of a Heat Pump Boiler, these levels ofefficiency are rarely achieved in Spring and Autumn, when different rooms may need heating and cooling from the airconditioning at the same time.

By using the VRF Heat Pump Boiler in a permanent heat recovery application, theseefficiencies are now possible all year round. This provides a reduction in running costs and CO2 emissions, both of which play a crucial role when obtaining planning permission as covered by the new Part L2 Legislation.

There is a further reduction in capital costs as there is very little or no requirement for gas boilers and associated works. Particularly when the small amount of heatingrequired in order to boost domestic hot water from the 45ºC (produced by the heat pump), to the required 60ºC supply temperature, can be provided by means of electric. Thus negating the need for the installation of a gas supply entirely.

Technical Information

An overview of the use of Heat Pump Boilers

Unit Flow Rate & Pressure DropFor calculating the Water Flow Rate please use the following calculation:Capacity (kW) = Flow Rate of Water (l/s) x Specific Heat Capacity of Water x (Outlet Water Temp(ºC) - Inlet Water Temp (ºC))

Specific Heat Capacity of water is normally 4.2Kj/KgK

Page 192

Page 194: 2008 Product Catalogue

PQFY-P140

PQFY-P250

Upper View >Front View >

Upper View >Front View >

Front control panel not shown

Front control panel not shown

Cit

y M

ulti

Ran

ge 2

008

PQFY

-P

Dimensions

Page 193

Page 195: 2008 Product Catalogue

BC Controllers

BC CONTROLLERSMODEL REFERENCE

NUMBER OF CONNECTIONS

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

POWER INPUT (KW)

RUNNING CURRENT (A)

FUSE RATING (BS88) – HRC (A)

MAINS CABLE No. Cores

CMB-P104V-G

4

24

648

362 + 70

284

220-240v, 50Hz

Single

0.085

0.36

6

3

CMB-P106V-G

6

29

648

362 + 70

284

220-240v, 50Hz

Single

0.123

0.52

6

3

CMB-P105V-G

5

27

648

362 + 70

284

220-240v, 50Hz

Single

0.104

0.44

6

3

Technical Information

At the heart of both the R2 and WR2 Series, the BC controller makes simultaneous heating and cooling possible. It has the inherent ‘intelligence’ to be the system’s decision-maker.

� Transferring energy around the system

� Drawing on energy from the heat source units/outdoor units

� Directing energy as requested by the individual indoor units

� Instructs the heat source unit/outdoor unit on the amount of refrigerant (liquid or gas) that is required to achieve the requested cooling or heating requirements

� Allows unique 2-pipe heat recovery application

� HIC Circuit for improved efficiency

Note: CMB-P-V-G units are for use with PURY-(E)P200-350 YHM-A & PQRY-P200/250YGM-A outdoor units only.

SLAVE BC CONTROLLERSMODEL REFERENCE

NUMBER OF CONNECTIONS

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

POWER INPUT (KW)

RUNNING CURRENT (A)

FUSE RATING (BS88) – HRC (A)

MAINS CABLE No. Cores

CMB-P104V-GB

4

22

648

362 + 70

284

220-240v, 50Hz

Single

0.076

0.32

6

3

CMB-P1016V-HB

16

57

1098

362 + 70

284

220-240v, 50Hz

Single

0.301

1.26

6

3

CMB-P108V-GB

8

32

648

362 + 70

284

220-240v, 50Hz

Single

0.151

0.63

6

3

Note: CMB-P1016V-HB can be connected to a CMB-P1016V-HA.

MASTER BC CONTROLLERSMODEL REFERENCE

NUMBER OF CONNECTIONS

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

POWER INPUT (KW)

RUNNING CURRENT (A)

FUSE RATING (BS88) – HRC (A)

MAINS CABLE No. Cores

CMB-P108V-GA

8

44

1110

450 + 70

289

220-240v, 50Hz

Single

0.161

0.68

6

3

CMB-P1013V-GA

13

57

1110

450 + 70

289

220-240v, 50Hz

Single

0.255

1.07

6

3

CMB-P1016V-HA

16

73

1110

450 + 70

289

220-240v, 50Hz

Single

0.312

1.30

6

3

CMB-P1010V-GA

10

49

1110

450 + 70

289

220-240v, 50Hz

Single

0.198

0.83

6

3

CMB-P1016V-GA

16

64

1110

450 + 70

289

220-240v, 50Hz

Single

0.312

1.30

6

3

Page 194

Note: CMB-P-V-GA units are for use with PURY-(E)P200-650Y(S)HM-A & PQRY-P200-500YSGM-A outdoor units only. CMB-P1016V-HA unit is for use with PURY-P700-800YSHM-A outdoor units only.

Page 196: 2008 Product Catalogue

CMB-P104, 105, 106V-G

CMB-P108, 1010, 1013, 1016V-GA/HA

CMB-P104, 108V-GB

Side View >Upper View >

CMB-P1016V-HB

A BCMB-P104V-GBCMB-P108V-GB

33

180420

Cit

y M

ulti

Ran

ge 2

008

BC C

ontr

olle

rs

Dimensions

Side View >Upper View >

Side View >Upper View >

Side View >Upper View >

Page 195

Page 197: 2008 Product Catalogue

Air Handling Unit Controller

PAC-AH-M-H - HEAT PUMP AHU CONTROLLERMODEL REFERENCE

MITSUBISHI ELECTRIC OUTDOOR UNIT

AIR HANDLING UNIT SIZE

ALLOWED EVAPORATOR CAPACITY (kW) - Heating

ALLOWED EVAPORATOR CAPACITY (kW) - Cooling

ALLOWED EVAPORATOR VOLUME (cm3)

STANDARD EVAPORATOR PATH NUMBER*

DIMENSIONS (mm) Width

( ) = Inc Mountings Depth

Height

WEIGHT (kg)

PAC-AH125M-H

PUHY-(E)P200-1250Y(S)HM-A

P100

10.0 - 12.5

9.0 - 11.2

1500 - 2850

4 - 5

326

117 (132)

410 (430)

7

PAC-AH125M-H

PUHY-(E)P200-1250Y(S)HM-A

P125

12.5 - 16.0

11.2 - 14.0

1900 - 3550

4 - 5

326

117 (132)

410 (430)

7

PAC-AH140M-H

PUHY-(E)P200-1250Y(S)HM-A

P140

16.0 - 18.0

14.0 - 16.0

2150 - 4050

5 - 6

326

117 (132)

410 (430)

7

PAC-AH250M-H

PUHY-(E)P200-1250Y(S)HM-A

P200

18.0 - 25.0

16.0 - 22.4

3000 - 5700

6 - 10

326

117 (132)

410 (430)

7

PAC-AH250M-H

PUHY-(E)P200-1250Y(S)HM-A

P250

25.0 - 31.5

22.4 - 28.0

3750 - 7100

8 - 10

326

117 (132)

410 (430)

7

Note: One air handling unit controller is required per air handling unitSaturated refrigerant temperature at exit of evaporator = 8.5ºC, SH=5K, liquid temperature = 25ºC, air = 27ºCDB/19ºCWB*When the diameter of the heat exchanger tube is ø9.52

M-NET wiring Thermistor wiring

Piping

Air Handling Unit (field supplied)

Controller (field supplied)

Outdoor Unit (Mitsubishi Electric)

Example:

Technical Information

The Air Handling Unit Controllers are an interface to allow connection to third party manufacturer equipment.

Mitsubishi Electric City Multi outdoor units can be used with this interface box, creating an ideal solution when a unique air handling unit is required. The Air Handling Unit Controllers are supplied with LEV expansion device(s).

PAC-AH-M-G - COOLING ONLY AHU CONTROLLERMODEL REFERENCE

MITSUBISHI ELECTRIC OUTDOOR UNIT

AIR HANDLING UNIT SIZE

ALLOWED EVAPORATOR CAPACITY (kW)

ALLOWED EVAPORATOR VOLUME (cm3)

STANDARD EVAPORATOR PATH NUMBER*

DIMENSIONS (mm) Width

( ) = Inc Mountings Depth

Height

WEIGHT (kg)

PAC-AH140M-G

PU(H)(R)Y-(E)P200-1250Y(S)HM-A

P140

11.2 - 16.0

2150 - 4050

5 - 6

326

117 (132)

382 (420)

7

PAC-AH250M-G

PU(H)(R)Y-(E)P200-1250Y(S)HM-A

P200

15.9 - 22.4

3000 - 5700

6 - 10

326

117 (132)

382 (420)

7

PAC-AH250M-G

PU(H)(R)Y-(E)P200-1250Y(S)HM-A

P250

18.7 - 28.0

3750 - 7100

8 - 10

326

117 (132)

382 (420)

7

Page 196

Air Handling Unit Controller (Mitsubishi Electric)

220-240v, 50Hz Power Supply

PAC-AH-M-G/H Heat Pump & Cooling Only

Page 198: 2008 Product Catalogue

Cit

y M

ulti

Ran

ge 2

008

Air

Han

dlin

g U

nit

Con

trol

lers

/ A

cces

sori

es

Accessories / Optional Extras

CMY-Y102S-G2CMY-Y102L-G2CMY-Y202-G2CMY-Y302-G2CMY-Y62-G-ECMY-Y100VBK2CMY-Y200VBK2CMY-Y300VBK2CMY-R100VBKCMY-R200VBKACH1ACOUSTIC KIT

PLP-6BASLP-2AAPLP-6BALMPLP-6BAJPAC-SA1ME-EPAR-SA9FA-ES70E40714

CMP-P40VLW-BCMP-P63VLW-BCMP-P100VLW-BCMP-P125VLW-BPAC-KH11OF

PMP-40BM

PAC-KE03DM-FPAC-KE04DM-FPAC-KE88LAFPAC-KE89LAFPAC-KE80TB-FPAC-KE140TB-F

CMY-R160-JCMY-Y102S-G

PAC-SE41TS-E

- Branch Pipe (Joint) for size 200 or below - total capacity of indoor units- Branch Pipe (Joint) for size 201-400 - total capacity of indoor units- Branch Pipe (Joint) for size 401-650 - total capacity of indoor units or first branch of P500-P650- Branch Pipe (Joint) for size 651 or above - total capacity of indoor units or first branch of P700-P1250- Branch Pipe for 2 branches (PUMY)- Twinning Kit for PUHY-P500-650YSHM-A / PUHY-EP400-650YSHM-A- Twinning Kit for PUHY-P700-900YSHM-A- Twinning Kit for PUHY-P950-1250YSHM-A / PUHY-EP700-900YSHM-A- Twinning Kit for PURY-P500-650YSHM-A / PURY-EP400-600YSHM-A- Twinning Kit for PURY-P700-800YSHM-A- PQFY Auto-Changeover controller- Acoustic kits for PUHY and PURY units

- Grille for PLFY-P-VBM-E- Grille for PLFY-P-VCM-E- Grille and infra-red controller for PLFY-P-VBM-E- Grille with filter lowering function for PLFY-P-VBM-E- ‘I -See Sensor’ corner panel for PLFY-P-VBM-E- Infra-red signal receiver for PLFY-P-VBM-E- Infra-red Controller (PAR-SL97A-E) for PLFY-P-VBM-E

- Grille for PLFY-P20-40VLMD-E- Grille for PLFY-P50-63VLMD-E- Grille for PLFY-P80-100VLMD-E- Grille for PLFY-P125VLMD-E- OA duct flange for PLFY-P20-100VLMD-E

- Grille for PMFY-P-VBM-E

- Drain lift-up mechanism for PEFY-P-VMM-E- Drain lift-up mechanism for PEFY-P-VMH-E- Long life filter for PEFY-P80VMH-E- Long life filter for PEFY-P100-140VMH-E- Filter box for PEFY-P80VMH-E (necessary when long life filter is used)- Filter box for PEFY-P100-140VMH-E (necessary when long life filter is used)

- Joint pipe- Branch pipe

- Remote sensor

Page 197

Outdoor Units

4-Way Blow Cassette Units

2-Way Blow Cassette Units

1-Way Blow Cassette Units

Ceiling Concealed Ducted Units

BC Controllers

Indoor Units

Page 199: 2008 Product Catalogue

LossnayTotal Heat Exchangers

Page 200: 2008 Product Catalogue

Poor air quality can be attributed to many problems arising in the workplace or inthe home. It is believed to contribute to a significant loss in productivity, low moraleand higher rates of sickness amongst many employees. The object of providing goodventilation alongside air conditioning in residential and commercial buildings is toprovide conditions under which people can live and work in comfort and safety.

Developed and refined over the past 30 years, theLossnay system has perfected the recovery of waste energy. The units reduce overall energy costs by extracting stale air and thenrecovering the heating or cooling energy to either warm or cool incoming fresh air.By utilising this energy, the Lossnay systemcan save up to 30% on initial capital costs ofheating and cooling plant.

Simple andExcellent air quality and unbeatable Heat Exchange Efficiency

Fresh air supply to the room

Stale room air extracted

Stale exhaust air

Fresh air from outside

Heat exchange unit(Lossnay core)

Page 200

Page 201: 2008 Product Catalogue

The Secretof the Lossnay System

The secret of the Lossnay system lies in the cross flow,plate fin structure of the heat exchange unit.

A diaphragm made of specially processed paper fully separates inlet and exhaust air supplies, ensuring that only fresh air is introduced to the indoor environment.

The superior heat-transfer and moisture permeability of the special paper ensures highly efficient total heat exchange (temperature and humidity) when inlet and exhaust air supplies cross in the Lossnay element.

Effective

Page 201

Page 202: 2008 Product Catalogue

Effective ventilationLossnay’s simultaneous air exhaust/supply provides effective ventilation.Conventional ventilators (i.e. extract propeller fans) do not work effectively within air tight buildings because of the negative air pressures involved.

Good energy recoveryTotal heat (sensible and latent) recovery provides a comfortable air temperaturewithin the room. The energy saved by using Lossnay contributes towards lowering the heating or cooling requirement within the building, therefore reducing the energy requirement and running costs.

Free cooling function (LGH series)When the outdoor temperature is lower than the indoor air conditioned temperature in the summer, Lossnay provides fresh outdoor cool air to reduce the indoor air temperature.

Good sound attenuationAs the Lossnay core is made of paper and the permeable holes are small, the Lossnay core provides outstanding soundproofing properties and is appropriate for sound proof rooms.

Part L2 Building RegulationsWith the introduction of Part L2 (Part J in Scotland), new building design is changing to become more airtight, as well as energy efficient. The need for freshair has remained the same however and thus poses new challenges for moderndesign. Lossnay fully meets these challenges due to its basic principal and its efficient heat recovery. See the Technical Information Section for CIBSE recommended fresh air rates.

Enhanced Capital Allowance (ECA)LGH-RX4 now qualifies for Enhanced Capital Allowances.

Main features of

Lossnay

Page 202

Page 203: 2008 Product Catalogue

Page 203

Operationin winter

4.6°CStale warm air (exhaust)

0°CFresh cool air (outdoor air)

20°CStale warm air

(indoor air)

15.4°CFresh warm air

(indoor supply air)

Heating unit

Operationin summer

25.6°CStale cool air (exhaust)

27°CFresh hot air (outdoor air)

21°CStale cool air (indoor air)

22.4°CFresh cool air

(indoor supply air)

Coolingunit

Using a Lossnay LGH-100RX4 in the winter example above, 8.9kW of heat is recovered per hour from the extracted air.

Total heat recover y

concept

Page 204: 2008 Product Catalogue

The graph opposite shows the hourly temperature for 2006 in London between 8.00am - 6.00p.m.The point to note is the amount of free cooling available during these hours, as well as the heatrecovery below (22% of the time) and cooling recovery above (20% of the time). Lossnay is a yearround solution for providing fresh air.

Lossnay working in conjunctionwith air conditioningLossnay units can work either on their own to provide fresh air into a room, or in combination with Mr Slim or City Multi ceiling cassettes and ducted units.

When working together with air conditioning, Lossnay units can provide significant energy savings by automatically utilising free cooling as well as heat recovery. As the Lossnay and the air conditioningunit are connected by a two core communication cable, they can work together to optimise bothcomfort and energy efficiency. This is done by the Lossnay reading the mode and set temperature the air conditioning wants, then utilising the outside temperature to help achieve the requiredtemperature either by free cooling or heat recovery.

When using Lossnay in conjunction with air conditioning the heating and cooling loads can bereduced significantly, reducing the running costs by up to 30% compared with air conditioning systems without heat recovery systems.

Lossnay fan speed button is incorporated within the standard PAR-21MAA and PAR-F27MEA controllers

Above example: One LGH25RX4 serving one PLA-RP71BA.Room size 7m x 7m, 140w/m2 heat load. 7 people per room,10litres/per/person of fresh to meet Part F requirements. Maximum amount of fresh air to be introduced is 30% of the fan coil volume. Ceiling cassettes may require fresh air casements.Free cooling is not available below 8ºC when interlocked with Mr Slim or City Multi units.

Page 204

Page 205: 2008 Product Catalogue

Page 205

Free cooling provided by Lossnay wasavailable in London over 58% of the time in 2006

Ambient Temperature - London 2006, 8am - 6pm

Over 58% of the time between 8am-6pm, the temperature in Londonwas between 8ºC and 20ºC, allowingfree cooling when the air conditioningsetpoint was 21ºC in cooling mode. If the setpoint is higher, free cooling is increased.

Page 206: 2008 Product Catalogue

Hyper Lossnay CoreLGH-RX4 Lossnay units feature the newly developed “Hyper Lossnay Core”, which uses non-porous, ultra-thin film toachieve high enthalpy exchange efficiency. With a thickness of only 25µm, these are the thinnest in the world and areapproximately one fifth the thickness of previous Mitsubishi Electric products. Moisture permeability is dramaticallyincreased and enthalpy heat exchange greatly improved.

Consists of a two-layer constructionusing a specially processed materialmade of a preferential permeable film on a porous base material. This provides moisture permeabilityand air barrier properties, but the two-layer construction makes a certain thickness unavoidable.

Consists of a specially processedstructure based on a single-layer, non-porous, ultra-thin film material.Moisture exchange (water vapourtransmission) is promoted by thespecial film, which increases theaffinity for moisture (the thinner the film, the higher the permeability).The non-porous ultra-thin filmmaterial acts as a barrier against air leakage.

Use

Hyper Lossnay Core material

Previous Mitsubishi Electric material

Photocopier paper

Dictionary paper

Thickness

25µm

120µm

100µm

51µm

The thinnest paper used in regular printing is 51µm thick (used in dictionaries) and the material of theHyper Lossnay Core is approximatelyhalf the thickness of this.

Comparison of material used in Hyper Lossnay Core (25µm ultra-thin film) with regular paper

Comparison of new and old Lossnay Core cross-sections

Previous Lossnay Core New Hyper Lossnay Core

Porous partition plate Non-porous film partition plate

120µm 25µm

Ducts can be connected in two different directions to the outdoorvents thanks to collars and aperture plates that can be interchangeablyplaced in two different positions. This flexibility allows for installationsclose to the surface of a wall and helps avoid cases where the staleair exhaust vent would be blocked by an obstruction of some kind.This makes both the planning and installation of Lossnay units thatmuch simpler.

Standard installation Installation with duct direction changed

A space is necessary to prevent the influx of rainwater.

Collar Aper ture Plate Exchangeable

Can beinstalled closeto the surfaceof the wall.

Changing the duct direction

Connect ducts in two different directions (Outdoor vents)

Because an adaptor now comes as standard equipment, networking LGH RX4 systems connected with Mitsubishi Electric’sline of air condi tioners has never been easier. There is no need to purchase any extra parts, creating the possibility of verysimple systems and keeping initial costs as well as construction time and trouble to an affordable minimum.

Interface simply

Page 206

Page 207: 2008 Product Catalogue

Page 207

Multi-Ventilation ModeEnables the appropriate supply/exhaust balance to be selected to suitusage, environment and location.

All LGH models feature the "Multi-ventilationMode," which allows the air supply/exhaustbalance to be varied dynamically to suit theusage environment and location. Modes canbe selected easily by setting the connectorson the circuit board.

* "High" can be further set to "Extra high" using the dip switch.

Normal Office Small Office or Building Smoking Areas

Providing efficient ventilation whilemaintaining air supply/exhaust balance...

Using Lossnay compensates for usingextractor fans...

Priority on air exhaust...

Power air supply& air exhaust

Most widely-used pattern formingthe basis for traditional ventilationdesign. This allows the most efficientventilation while maintaining the airsupply/exhaust balance. The optimumventilation rate can be maintained byselecting the Power air supply/exhaustmode with both the air supply & air exhaust switched to "High" (or "Extra high") on the main unit. For example in an office, the controlswitches can be set to "High" to runin Power air supply/exhaust modewhen a large number of people are in the office, then switched to "Low"to run in Energy-saving ventilationmode late at night or on holidayswhen there are few people present.

In smaller offices or buildings, theremay be insufficient air supply to themain rooms or offices due to theexcessive exhaust via extractor fanslocated in toilets or kitchen areas.Setting to Power air supply mode with the air supply switch on "High" (or "Extra high") and the air exhaust switch on "Low" on the main unit, allows efficient ventilation while making up for the insufficient air supply.

In locations such as smoking areas,dirty air must be exhausted swiftly.Setting the Power air exhaust modewith the air supply switch on "Low"and the air exhaust switch on "High"(or "Extra high") on the main unitallows efficient extraction of cigarettesmoke and odours. Maintaining thearea at a negative air pressure alsoprevents dirty air from spreading to surrounding areas.

Power air supply Power air exhaust

Power air supply/exhaust mode

Power air supply mode

Power air exhaust mode

Energy-saving ventilation mode

Ventilation Mode

High

High

Low

Low

SupplyAirflow

High

Low

High

Low

Exhaust Airflow

Page 208: 2008 Product Catalogue

Enhanced Capital Allowance & Part L2 The need for energy efficiency is paramount and is determined by legislation and regulation. To encourage efficient use of energy, the UK Government introduced the Enhanced CapitalAllowance Scheme (ECA). The number of qualifying products on the Energy TechnologyProduct List has recently been expanded and includes ‘air to air energy recovery’.The Lossnay heat recovery units (LGH-RX4) have been designed to ensurebusinesses qualify for ECA and benefit from the utmost efficiency, both financially and environmentally.

How Enhanced Capital Allowances WorkEnhanced Capital Allowances are used to encourage businesses to invest in particular typesof equipment by providing up-front tax relief, as 100% of the allowances can be reclaimed in the first year. So, using the below example of a £1000 investment in equipment that qualifies for ECA’s, the company could reclaim £300 in the first year.

Enhanced Capital AllowanceTax Rate 30%

% of expenditure to which allowance applies 100%

Equipment plus installation costs £1000

Taxable amount reduced by 100% OF £1000 = £1000

FIRST YEAR SAVING 30% of £1000 = £300

Part L2 of the Building Regulations is undergoing a major change. With buildingregulations tightened up from April 2006, new commercial buildings have to bepressure tested to show they are airtight and energy efficient. Proof willalso be needed to show that the new buildings will not overheat and the occupants will be able to work comfor tably. This means that the fresh air requirements are even moreimportant than ever before. Lossnay offers many featuresthat will help the building designer as well as the occupantsand with Lossnay’s high efficiency, unique controllability andits modular design approach, Lossnay will assist greatly in Part L2 compliance.

Part L2

Page 208

Page 209: 2008 Product Catalogue

Page 209

Enhanced Capital Allowance Scheme (ECA)

� Under the scheme, all businesses liable for UK corporation tax, are able to claim an enhanced capital allowance on anyqualifying expenditure (regardless of size and location of business or whether in the industrial or commercial sector)

� Businesses can offset the full cost of specific technologies (such as Lossnay) against taxable profits of the period of the investment

� In order to qualify for this scheme, technology has to meet the energy saving criteria as published in the Energy Technology Criteria List. Our LGH-RX4 Lossnay systems fully meet this criteria in their drive for energy efficiency

� Only investment in new and unused plant and machinery qualify

For further instructions go to www.eca.gov.uk and click on Mitsubishi Electric Air Conditioning under the air to air energy recovery category.

The key features of the ECA scheme:

Page 210: 2008 Product Catalogue

Restaurants Schools

The atmosphere of a restaurant is crucial to securing and retaining customers. Cleanliness is the key to an attractive atmosphere and restaurants devote significant effort to ensuringtheir premises are sanitary. Sanitation and cleanliness,however, are not enough. No matter how clean a restaurant may look, if there are bothersomeodours lingering in the air, all those efforts go to waste and the restaurant's clean image is tarnished. For these reasons, Lossnay’s superiorventilation capabilities ensure that every breath isa fresh one and a pleasant environment ismaintained for guests at all times. Lossnay alsokeeps owners happy with its remarkable heatrecovery technology that supplies fresh outdoorair with minimal change to indoor temperature,saving on energy costs.

A restaurant can never be tooclean and its air never too fresh

Creating the best possible environment for our children to succeedChildren deserve all the help we can give them to grow up healthy, happy and prosperous. No matter how good a school's curriculum, no matterhow positive and enthusiastic the teacher, a child whodoes not feel well will have a hard time learning. A constant flow of fresh air is nowhere as important as it is in our schools. In classroomswhere large numbers of students are gathered for long periods of time, carbonic gases have the tendency to accumulate, decreasing the levelsof oxygen that are vital for aler tness and concentration. This is especially true during thewinter months when windows tend to remainclosed. Lossnay ventilates fresh outdoor air intoclassrooms to replenish the supply of oxygen and expels not only carbon dioxide, but also otherpollutants and odours that inevitably sully the air.

Lossnay works to remove stale air and supplyfresh, clean air free of the odours associated

with cooking, cigarettes and the people working and dining.

Change in room temperature is kept to a minimum during ventilation thanks to the

heat-recovery function.

The Lossnay operate very quietly, so those inthe midst of enjoying their meals will not be

bothered by any excess noise.

A large array of Lossnay sizes are available tomatch the layout of just about any restaurant.

The continuous influx of fresh, outdoor air andthe exhaust of stale, indoor air ensure that theindoor oxygen level is maintained at just the

right balance for comfort and health.

Occupants have the luxury of breathing freshair at all times even in highly air-tight buildings.

Lossnay's sound attenuation qualities preventoutside noise from penetrating into the room,helping to maintain a quiet environment for

productive study.

Heat-exchange technology prevents fluctuationsin temperature creating significant energy

savings when either heating or cooling a room.

If it’s Lossnay If it’s Lossnay

%3.25What would you most like to see improved in restaurants?

Others: no response

Promotion of waste prevention: 5.4%

Improvement in atmosphere: 6.5%

Reduction of time required forfood to reach the table: 12.0%

Improvement in employees attitude towards customers: 20.5%

Improvement in overallcleanliness

1996 Foodstuffs Consumption Monitor, Second Periodic Survey ( Ministry of Agriculture, Forestry and Fisheries, Japan) In

crea

sed

resp

irat

ion

and

puls

e

O2 Concentration and Deficiency

21

15

10

5

0 Nor

mal

air

Safe

ty m

inim

um

O2

Con

cent

ratio

n (%

)

Diz

zine

ss, n

ause

a,lo

ss o

f mus

cle

stre

ngth

(pr

ecur

sors

of d

eath

)

Pale

ness

of s

kin,

vom

iting

,U

ncon

scio

usne

ss

Com

atos

is(d

eath

in 8

min

)

Con

vulsi

ons,

resp

iratio

nst

ops,

deat

h

21 %18 %

16 %

12 %10 %

8 %

6 %

Page 210

Page 211: 2008 Product Catalogue

Page 211

Many office buildings today are heavily insulated, air-tight structures with little or no natural ventilation. The unnaturalenvironment created by air conditioners without added ventilation is a breeding ground for bacteria. Factor this in with the accumulation of pollutants and odours in the form ofcigarette smoke, formaldehyde, pollen, dust, carbon dioxideand the necessity of ventilation becomes ever more apparent.In fact, poorly ventilated buildings can give rise to Sick BuildingSyndrome, a malady that is known to cause headaches, soreeyes, itching and loss of concentration. This results not only in discomfort at best and sickness at worst for the building'soccupants, but also the reduced productivity of the workforce.Fresh air, effectively ventilated throughout the building is therefore essential to the overall quality of working life.

Simultaneous forced-air supply and exhaust introduces fresh, outdoor air into the building,effectively ventilating even fully airtight structures.

Multiple split-type units operate independently of one another, simplifying system set up and

ensuring a layout that optimally matches nearly any office design.

Lossnay operation can be interlocked withair-conditioning system operation.

Heat that is commonly lost due to ventilation is collected and reused thanks to the

Lossnay Core, reducing an air conditioners energy load and cutting operating costs.

OfficesFresh air - improving the overallquality of working life

If it’s Lossnay

Lossnay Selection / Payback Softwareand Quick Reference Guide available to order from your local sales office

Page 212: 2008 Product Catalogue

The unbeatable

LossnayThe Lossnay al lows the extraction of stale

air and efficient recover y of heating

or cooling energy to treat

incoming fresh air. Whatever

your environment, it ’s simple to improve

it with Lossnay.

Systems marked with the ECA logo are registered on the Energy Technology List andhence qualify for 100% first year enhanced capital allowances (whole system cost and ‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk

Nominal conditions cooling: indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.Nominal conditions heating: indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. Winter; indoor 21˚C DB; outdoor -1˚C WB.

S imple technologyat its best

Page 212

Page 213: 2008 Product Catalogue

Page 213

Total Heat Exchangers Residential Model

LGH-RX4 Commercial Series

180

182

214

216

Contents

Page 214: 2008 Product Catalogue

Residential Model

Total Heat Exchangers

LOSSNAYMODEL REFERENCE

ELECTRICAL POWER SUPPLY

PHASE

POWER CONSUMPTION (W) Low

High

AIRFLOW (m3/h) Low

High

NOISE (dBA) Low

High

Low

High

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

DUCT SIZE (mm)

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

RESIDENTIAL WALL- MOUNTED VL 100U

220 - 240V, 50Hz

Single

23

26

65

105

29.5

39

77

70

6.5

620

168

265

2xØ75

6

3

TEMPERATUREEXCHANGEEFFICIENCY (%)

Technical Information

Particularly suitable for modern homes with high insulation afforded by double glazing and cavity insulation, which require ventilation to remove stale air without major heat loss.

� Effective fresh air ventilation

� Efficient recovery of heating/cooling energy

� Good sound attenuation

� Reduces heating costs

Page 214

Page 215: 2008 Product Catalogue

VL 100U

Tota

l Hea

t Exc

hang

ers

Resid

entia

l Mod

elLo

ssna

yR

ange

200

8Dimensions

Page 215

Page 216: 2008 Product Catalogue

LGH-RX4

LOSSNAYMODEL REFERENCE

ELECTRICAL POWER SUPPLYSTARTING CURRENT (A)RUNNING CURRENT (A) Low

HighExtra High

INPUT POWER (W) LowHighExtra High

AIRFLOW (m3/h) LowHigh / Extra High

AIRFLOW (l/s) LowHigh / Extra High

EXTERNAL STATIC LowPRESSURE (PA) High

Extra HighNOISE (dBA) Lossnay Low

HighExtra High

Bypass LowHighExtra High

TEMPERATURE LowEXCHANGE HighEFFICIENCY (%) Extra HighENTHALPY Heating LowEXCHANGE High / Extra HighEFFICIENCY (%) Cooling Low

High / Extra HighWEIGHT (kg)DIMENSIONS (mm) Width

DepthHeight

DUCT SIZE (mm)STANDARD FILTER*1

FUSE RATING (BS88) – HRC (A)MAINS CABLE NO. CORES

COMMERCIALLGH-25RX4

220-240V, 50Hz0.80.250.400.49599611716525046692550802326

27.523

26.528

83.578787770716521735780275150EU3

63

COMMERCIALLGH-35RX4

220-240V, 50Hz1.70.480.710.79110167187230350649725701502430322430

32.58479797770

74.56830874888317150EU3

63

COMMERCIALLGH-50RX4

220-240V, 50Hz1.90.600.900.9514221422535050097139306015024.531.534

25.533

35.5827777

73.567.571.564.533

1016888317200EU3

63

COMMERCIALLGH-80RX4

220-240V, 50Hz3.61.401.601.70315370385670800186222701001403133

34.531.534

35.580.57878

73.571

70.56761

10041164398250EU3

63

COMMERCIALLGH-100RX4

220-240V, 50Hz5.41.702.002.1040047549087010002422788010016032.5353734

36.5388179797471

69.56769

12311164398250EU3103

COMMERCIALLGH-150RX4

220-240V, 50Hz7.22.703.103.30625730770125015003474177010014033.536.537.536.538.540

81.57979

74.572726812410041164800

(SA,RA)250 (OA,EA)270x700EU3163

COMMERCIALLGH-200RX4

220-240V, 50Hz10.83.504.204.30820980101016502000458556659015036384037

39.541

81.579797571716714012311164800

(SA,RA)250 (OA,EA)270x700EU3163

COMMERCIALLGH-15RX4

220-240V, 50Hz0.70.220.310.4551731071101503142356095232527232527817777747070

64.517610780275100EU3

63

Notes: Running Current, Input Power and Recovery Efficiency are based on the above airflow rate, power supply 240v, 50Hz. Extra High mode available via dip switch setting. Noise measured at 1.5m under the centre of panel.*1: Eu7 filter available as optional parts.

Fresh air supply to the room

Stale room air extracted

Stale exhaust air

Fresh air from outside

Heat exchange unit(Lossnay core)

Commercial Series

Technical Information

This commercially orientated system can be utilised virtually anywhere.

� Effective fresh air ventilation

� High heat recovery

� Free cooling function

� Good sound attenuation

� New “Hyper Lossnay Core”. At only 25µm (approx 1/5 the thickness of LGH-RX3) the Lossnay core uses the thinnest paper in the world to achieve high enthalpy exchange efficiency

Page 216

Page 217: 2008 Product Catalogue

MODEL REFERENCE

LGH-150RX4

LGH-200RX4

A

1004

1231

B

690

920

C

1046

1273

LGH-15RX4 to LGH-200RX4

M-NET Controller

PZ-52SF-E (M-NET)Control 16 Lossnay units from sizes 15 -100 or up to 8, sizes 150 - 200

70

48

8 33

120

70

48

8 33

120

Lossnay Controller

PZ-41SLB-EControl 15 Lossnay units from sizes 15 -100 or up to 7, sizes 150 - 200

MODEL REFERENCE

LGH-15RX4

LGH-25RX4

LGH-35RX4

LGH-50RX4

LGH-80RX4

LGH-100RX4

A

780

780

888

888

1164

1164

B

610

735

874

1016

1004

1231

C

275

275

317

317

398

398

D

700

700

790

790

1030

1030

E

641

765

906

1048

1036

1263

ø100

ø150

ø150

ø200

ø250

ø250

DIMENSIONS NOMINALDIAMETER

CEILING SUSPENSION FIXTURE PITCH

LGH-15-100RX4 > LGH-150-200RX4 >

LGH

RX

4 C

omm

erci

al S

erie

sLo

ssna

yR

ange

200

8Dimensions

Page 217

Page 218: 2008 Product Catalogue

ControlsA comprehensive range of control options

Page 219: 2008 Product Catalogue

The importance ofThe need for control is paramountin order to optimise the performanceof any air conditioning system and minimise its running costs.Mitsubishi Electric offer a widerange of control options designedto do just this.

Operating an air conditioning system without

the right control can prove costly. It’s therefore

important to ensure that every system is

correctly specified to the degree of control it

requires. Mitsubishi Electric have a wide range

of controls available ‘off-the-shelf ’ and where

needed, individual control systems can be

specifically designed to suit.

Good controls will benefit any application, large

or small. Air conditioning products need to

react to a variety of factors: different room

sizes, usage and staff levels; changes in the

climate; electronic equipment and lighting ... the

list goes on. So whatever the application,

optimum control of air conditioning systems

is essential and will result in a constant,

comfortable environment, which in turn is both

energy and cost efficient.

A degree of

differenceWhen an air conditioning system is not properly

controlled, it will not run as efficiently as it should.

For every degree that the system deviates from

the required temperature, energy costs can rise

by up to 5%. Specify one of the many control

options from Mitsubishi Electric to ensure

air conditioning works as intended, whilst giving

the optimum amount of control.

The simpler

the betterWith the array of comprehensive control

systems available from Mitsubishi Electric,

it becomes simple to design and install air

conditioning systems. From a simple hand held

controller to a G50 system - you are in control.

Page 220

Page 220: 2008 Product Catalogue

Controlled

performanceIn accordance with the requirements of part L2 in the Building Regulations, our control systems

provide the optimum control available, combined with the most efficient use of energy.

Control

Page 221: 2008 Product Catalogue

A wide range of

Controls options

The need for control is paramount in order

to optimise the performance of any air conditioning

system and minimise its running costs.

Mitsubishi Electric offer a wide range of

control options designed to do just this.

S imple technologyat its best

Page 222

Page 222: 2008 Product Catalogue

Remote Controllers

Programmable Timer

System Controller

Interfaces

G50 Controller, Centralised Controller

AG150 Controller, Centralised Controller

GB50 Controller, Centralised Controller

G50/GB50/AG150 Controller, Web Screenshots

G50/GB50/AG150 Desktop Remote Controller

G50/GB50/AG150 Third Party Equipment Interfaces

G50/GB50/AG150 Programmable Logic Controller (PLC)

TG2000 Software, PC Based Software Package

TG2000 Software with Energy Monitoring

TG2000 Software with Third Party Equipment

TG2000 WAN Software (Wide Area Network)

TG2000, Screenshots

BEMS BACnet® Interface (BAC-IP/50)

BEMS BACnet® Mr Slim Interface (BAC-A/50)

BEMS LonWorks® Interface (LMAP)

BEMS Modbus Interfaces (IP-32/50/100M)

BEMS Modbus Mr Slim Interface (A32M)

BEMS Modbus Splits Interface (A1M)

BEMS KNX-EIB Interfaces (KNX-EIB-IP-15/100)

BEMS KNX-EIB Splits Interface (KNX-EIB-A-1)

M2M - Machine 2 Machine Interface (Maxi M2M-IP/50)

M2M - Machine 2 Machine Splits Interface (Mini M2M-A/16)

M2M - Machine 2 Machine Web Screenshots

G50 Control Panels

Run / Standby Control Panels

Energy Monitoring Control Panels

Split-System A2M Interfaces

224

225

226

227

228

229

230

231

232

233

234

235

236

237

238

239

240

241

242

243

244

245

246

247

248

249

250

251

252

253

254

Contents

Page 223

Page 223: 2008 Product Catalogue

Remote Controllers

Remote Controllers

PAR-FL32MAPAR-21MAA PAR-F27MEAPAC-YT51CRA PAC-SE51CRA BS-51COV PC-51COV PB-51COV

ON/OFF

MODE SELECTION

TEMPERATURE SETTING

FAN SPEED SETTING

SETPOINT LIMIT

AIRFLOW DIRECTION

INDEPENDENT VANECONTROL

TIMER OPERATION

PERMIT / PROHIBITFUNCTION

INDOOR RETURN AIR TEMPERATURE

ERROR INDICATION

TEST RUN FUNCTION

VENTILATION INTERLOCK

OPTIONAL COVER

CONTACT NUMBERUNDER FAULT CONDITIONS

MULTIPLE LANGUAGES

CLOCK DISPLAY

BUTTON LOCK

EASY MAINTENANCEWITH MR SLIM

RUN / STANDBY WITHMR SLIM

COMPATIBILITY

DIMENSIONS - mm(WxDxH)

FUNCTION

Run and Stop operation for a single group

Switches between Cool/Dry/Auto/Fan/Heat.Operation mode will vary depending on theindoor unit. Auto mode is available with only R2 and WR2 systems

Sets the groups temperature control. Cool/Dry: 19-30°C Heat: 17-28°C Auto: 19-28°C

4 speed - Lo-Mi1-Mi2-Hi 2 speed - Lo-Hi

Limit the setpoint range

Air Flow angles:100º-80º-60º-40ºand auto swing

Only available with PLA-RP-BA, PLFY-P-VBM-E and PLFY-P-VCM-E

ON/OFF time can be set.

Run/Stop, Temperature Setting, Mode Selectionand Filter Reset functions can be prohibited via a higher level system controller

Measures the intake temperature of the master unit within the group

Displays a 4 digit code and the affected unit address

Allows each unit within the group to operate in test mode

Allows the group to be interlocked with a heat recovery Lossnay unit

Brushed Stainless Steel

Polished Chrome

Polished Brass

Displays under fault condition, the fault code of the unit with its address and the contact number to call

English, Italian, Spanish, French, German, Russian, Chinese and Japanese

Displays time

Able to lock all controller buttons, or all controller buttons except On/Off

Able to monitor information about thecompressor (running current, running time,On/Off time). Also able to monitor sensors: h-exh, outdoor outlet, outdoor temp, indoor inlet,indoor h-exh and filter use number of hours

Able to switch over two systems every week. If one fails, the other system starts. If thetemperature is too high, the two systems start.

Compatible with:

DESCRIPTION PAC-YT51CRA PAC-SE51CRA PAR-21MAA PAR-F27MEA PAR-FL32MA

Weekly Weekly Daily Daily Daily Daily

Our air conditioning systems are supported by a multitude of remote controllers. Each remote controller type,whilst being able to support the general control and monitoring functions for a group of indoor units, can also offer other unique operational features.

Mr Slim or M Series (via MAC-397IF) City Multi

Mr Slim or M Series (via MAC-397IF)

City MultiCity Multi, Mr Slim or

M Series (via MAC-397IF)

120x41x70 120x41x70 130x19x120 130x19x120 157x18x57

Operation Display Operation Display Operation Display Operation Display Operation Display

� � � � � � � � � �

� � � � � � � � � �

� �

� �

� � � �

� � � �

� �

� �

� �

� �

� �

� �

� �

� � � � � � � �

� � � � �

� �

� � � �

� �

� �

� �

� � � � � � � �

Technical Information

Page 224

� �

Page 224: 2008 Product Catalogue

Programmable Timer

PAC-YT34STA

Programmable Timer

Mitsubishi Electric controllers are complimented by a weekly programmable timer, being ableto control up to fifty indoor units. The PAC-YT34STA also has hardwired connection available (On/Off input, fire alarm input, run output, fault output).

PAC-YT34STA PAC-SC50KUA

Con

trol

sR

ange

200

8R

emot

e C

ontr

olle

rs /

Pro

gram

mab

le T

imer

Technical Information

UNITS

ON/OFF

MODE SELECTION

TEMPERATURE SETTING

CURRENT TIME

ERROR INDICATION

EXTERNAL INPUT

EXTERNAL OUTPUT

COMPATIBILITY

DIMENSIONS - mm(WxDxH)

FUNCTION

Max No. of Indoor Units

Run and Stop operation

Switches between Cool / Heat

Sets the groups temperature control. Cool/Dry: 19-30°C Heat: 17-28°C Auto: 19-28°C

Set the time

Displays a 4 digit code and the affected unit address

Hardwired connections available

Hardwired connections available

Compatible with:

50 units/50 groups 50 units/50 groups

DESCRIPTION PAC-YT34STA

� �

� �

� �

� �

� �

City Multi or Mr Slim via PAC-SF80MA or M Series via MAC-399IF

130x19x120

Operation Display

On/Off or Fire Alarm

Run/Faults

NOTE: Units can only be controlled from the scheduling options. When the remote On/Off hardwired input is used, the On/Off remote controller buttons will be deactivated (centrally controlled).

Page 225

Page 225: 2008 Product Catalogue

PAC-SC50KUAPAC-SF44SRA PAC-SF44SRA

System Controller

UNITS

ON/OFF

MODE SELECTION

TEMPERATURE SETTING

FAN SPEED SETTINGS

AIR FLOW DIRECTION

PERMIT/PROHIBITFUNCTION

INDOOR RETURN AIR TEMPERATURE

ERROR INDICATION

VENTILATIONINTERLOCK

EXTERNAL INPUT

EXTERNAL OUTPUT

COMPATIBILITY

DIMENSIONS - mm(WxDxH)

FUNCTION

Max No. of Indoor Units

Run and Stop operation

Switches between Cool/Dry/Auto/Fan/Heat.Operation Mode will vary depending on theindoor unit. Auto mode is available with only R2 and WR2 systems

Sets the groups temperature control. Cool/Dry: 19-30°C Heat: 17-28°C Auto: 19-28°C

4 speed - Lo-Mi1-Mi2-Hi 2 speed - Lo-Hi

Air Flow angles: 100º-80º-60º-40º and auto swing

Run/Stop, Temperature Setting, Mode Selectionand Filter Reset functions can be prohibited

Measures the intake temperature of the master unit within the group

Displays a 4 digit code and the affected unit address

Allows the group to be interlocked with a heat recovery Lossnay unit

Hardwired connections available

Hardwired connections available

Compatible with:

50 units/50 groups 50 units/50 groups

DESCRIPTION PAC-SF44SRA

� � �

� �

� �

� �

� �

� �

� �

� �

Operation Display

On/Off or Fire Alarm

Run/Faults

City Multi or Mr Slim via PAC-SF80MA or M Series via MAC-399IF

130x19x120

System ControllerOne system controller is available for use when you need to control up to fifty indoor units from one location. The PAC-SF44SRA also has hardwired connection available (On/Off input, fire alarm input, run output, fault output).

Technical Information

Page 226

NOTE: When the remote On/Off hardwired input is used, the On/Off remote controller buttons will be deactivated (centrally controlled).

Page 226: 2008 Product Catalogue

InterfacesA range of newly created interfaces are now available for use when connecting to third party controllers.

DIDOTCB1

DIDOTCB1

Interfaces

ON/OFF BUT CENTRALLYCONTROLLED

ON/OFF BUTNOT CENTRALLYCONTROLLED

TEMPERATURESETTINGS

ERROR INDICATION

HEATINGINTERLOCKING

COMPATIBILITY

DIMENSIONS - mm(WxDxH)

FUNCTION

ON/OFF control. Remote controller ON/OFF button deactivated

ON/OFF control. Remote controller ON/OFF button activated

Sets the groups temperature control. Cool/Dry: 19-30°C Heat: 17-28°C Auto: 19-28°C

A supplied remote sensor is installedon the wet system radiator to prevent the air conditioning running while heating

Interface compatible with:

DESCRIPTION TCB1 DIDO MS-FRT-TCB-TEMP

Con

trol

sR

ange

200

8

Technical Information

Control Monitor Control Monitor Control Monitor

80x45x80 130x19x120 130x19x120

Mr Slim

City Multi

Mr Slim

City MultiMr Slim

� � � �

(analogue 0 to 10VDC)

� �

Syst

em C

ontr

olle

r /

Inte

rfac

es� � � � � �

Page 227

Page 227: 2008 Product Catalogue

Centralised Controller with WebServer Capabilities

G50 Controller

The G50 centralised controller was the first of its kind in the industry to utilise Ethernet Technology. By using InternetExplorer as its local or remote software, the G50 gives you instant access to all your control functions from the comfort ofyour own PC. The G50 can control up to 50 indoor units and can take the place of local remote controllers, offeringthe same level of monitoring and control. The G50 has many functions as standard but can also have further featuresactivated via Pin Codes.

G50 - Web MonitorG50 - EmailG50 - ASG50 - EC

Control and Monitor the G50 via Internet ExplorerEnable E-mail activation on fault conditionsWeekly / Annual Scheduling and Night Set BackEnergy Charge

G50 Software Options - Pin Code ActivationG50 - ESG50 - PCG50 - VRC

G50 Controller

OPERATION PLATFORM

MAX No. OF INDOOR UNITS

ON/OFF

MODE SELECTION

TEMPERATURE SETTING

FAN SPEED SETTING

AIR FLOW DIRECTION

TIMER OPERATION

PERMIT/PROHIBIT FUNCTION

INDOOR RETURN AIR TEMPERATURE

ERROR INDICATION

TEST RUN FUNCTION

VENTILATION INTERLOCK

WEB SETPOINT LIMIT

WEB AUTO CHANGEOVER

WEB INITIAL SETTING

WEB LOGIN

EXTERNAL INPUT/OUTPUT

POWER SUPPLY PACK

COMPATIBILITY

DIMENSIONS - mm (WxDxH)

FUNCTION

Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000service pack 4 or Windows Professional XP service pack 2 or Windows Vista

Up to 50 indoor units can be connected

Run and Stop operation for a single group

Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit.Auto mode is available with only R2 and WR2 systems

Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C

4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi

Air Flow angles:100º-80º-60º-40º and auto swing

Weekly. Maximum of 3 time sequences with 3 Start/Stop times per day for all groups can be allocated

Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated

Displays the measured intake temperature from each group

Displays a 4 digit code and the affected unit address. An error log is held showing the last 64 date stamped alarms

Allows each unit within the group to operate in test mode

Allows the group to be interlocked with a heat recovery Lossnay unit

Reduce the setpoint band of each individual unit (e.g. 23ºC to 25ºC)

Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements

Commission the G50 from the web pages

Administrator able to allow specific function access to guest

Hardwired connections are available for : Inputs: Level Signal-Batch Start/Stop, Batch Emergency StopOutputs: Start/Stop Status, Error/Normal Status

PAC-SC50KUA

City Multi or Mr Slim via PAC-SF80MA or M Series via MAC-399IF

300x79x120

DESCRIPTION

Technical Information

Energy Saving CapabilityPeak Cut Control Virtual Remote Controllers

ETHERNET

G50

Viewed using Microsoft® Internet Explorer

M-NET

PAC-SC50KUA

Page 228

Page 228: 2008 Product Catalogue

Touch Screen Centralised Controller with WebServer Capabilities

AG150 Controller

The new AG150 Mitsubishi Electric centralised controller offers a large 9 inch touch screen display with easy controlof up to 50 indoor units. The AG150 can calculate the energy used for each system, zone or indoor unit. The refrigerant status check function can be activated regularly (in conjuction with the new YHM-A City Multi range) and an Internet connection with SSL security is also available to monitor and control the AG150 remotely andreceive Email under fault conditions.

AG150 - BasicAG150 - EnergyAG150 - VRC

Web monitoring, Email, Annual schedulingEnergy monitoring, energy saving, load sheddingVirtual remote controllers

AG150 Software Options - Pin Code Activation

AG150 Controller

OPERATION PLATFORM

MAX No. OF INDOOR UNITS

ON/OFF

MODE SELECTION

TEMPERATURE SETTING

FAN SPEED SETTING

AIR FLOW DIRECTION

TIMER OPERATION

PERMIT/PROHIBIT FUNCTION

INDOOR RETURN AIR TEMPERATURE

ERROR INDICATION

TEST RUN FUNCTION

VENTILATION INTERLOCK

WEB SETPOINT LIMIT

WEB AUTO CHANGEOVER

WEB INITIAL SETTING

WEB LOGIN

WEB REFRIGERANT STATUS CHECK

ENERGY CHARGING

ENERGY SAVE CONTROL

LOAD SHEDDING

EXTERNAL INPUT/OUTPUT

POWER SUPPLY PACK

COMPATIBILITY

DIMENSIONS - mm (WxDxH)

TOUCH SCREEN

FUNCTION

Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista

Up to 50 indoor units can be connected

Run and Stop operation for a single group

Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit.Auto mode is available with only R2 and WR2 systems

Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C

4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi

Air Flow angles:100º-80º-60º-40º and auto swing

Annual or weekly. Night set back option available allowing the setpoint to be set to 12ºC

Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated

Displays the measured intake temperature from each group

Displays a 4 digit code and the affected unit address. An error log is held showing the last 64 date stamped alarms

Allows each unit within the group to operate in test mode

Allows the group to be interlocked with a heat recovery Lossnay unit

Reduce the setpoint band of each individual unit (e.g. 23ºC to 25ºC)

Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements

Commission the G50 from the web pages

Administrator able to allow specific function access to guest

Activate refrigerant volume checking function on Modular City Multi systems

Able to create bills for individual indoor units, groups of indoor units or a complete system (Optional) via the PAC-YG60MCA

Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional)

Activate energy saving mode when energy consumption is too high

Hardwired connections are available for : Inputs: Level Signal-Batch Start/Stop, Batch Emergency StopOutputs: Start/Stop Status, Error/Normal Status

PAC-SC51KUA

City Multi or Mr Slim via PAC-SF80MA or M Series via MAC-399IF

300x62x175

Wide high resolution 9” touch screen

DESCRIPTION

Technical Information

ETHERNET

AG150

Viewed using Microsoft® Internet Explorer

M-NET

PAC-SC51KUA

Page 229

NEW in September 2008

Con

trol

sR

ange

200

8G

50 C

ontr

olle

r / A

G15

0 C

ontr

olle

r

Page 229: 2008 Product Catalogue

Centralised Controller with WebServer Capabilities

GB50 Controller

G50 - ECG50 - ESG50 - PCG50 - VRC

Energy ChargeEnergy Saving CapabilityPeak Cut Control Virtual Remote Controllers

GB50 Software Options - Pin Code Activation

ETHERNET

GB50

The GB50 has been developed to access all your control functions from the comfort of your own PC, without the need for a controller keypad or LCD display and at a very competitive price.

GB50 Controller

OPERATION PLATFORM

MAX No. OF INDOOR UNITS

ON/OFF

MODE SELECTION

TEMPERATURE SETTING

FAN SPEED SETTING

AIR FLOW DIRECTION

TIMER OPERATION

PERMIT/PROHIBIT FUNCTION

INDOOR RETURN AIR TEMPERATURE

ERROR INDICATION

TEST RUN FUNCTION

VENTILATION INTERLOCK

WEB SETPOINT LIMIT

WEB AUTO CHANGEOVER

WEB INITIAL SETTING

WEB LOGIN

EXTERNAL INPUT/OUTPUT

POWER SUPPLY PACK

COMPATIBILITY

DIMENSIONS - mm (WxDxH)

FUNCTION

Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista

Up to 50 indoor units can be connected

Run and Stop operation for a single group

Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems

Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C

4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi

Air Flow angles:100º-80º-60º-40º and auto swing

Annual or weekly. Night set back option available allowing the setpoint to be set down to 12ºC

Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated

Displays the measured intake temperature from each group

Displays a 4 digit code and the affected unit address. An error log is held showing the last 64 date stamped alarms

Allows each unit within the group to operate in test mode

Allows the group to be interlocked with a heat recovery Lossnay unit

Reduce the setpoint band of each individual unit (e.g. 23ºC to 25ºC)

Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements

Commission the GB50 from the web pages

Administrator able to allow specific function access to guest

Hardwired connections are available for : Inputs: Level Signal-Batch Start/Stop, Batch Emergency StopOutputs: Start/Stop Status, Error/Normal Status

PAC-SC50KUA

City Multi or Mr Slim via PAC-SF80MA or M Series via MAC-399IF

250x38x130

DESCRIPTION

Technical Information

M-NET

PAC-SC50KUA

Viewed using Microsoft® Internet Explorer

Page 230

Page 230: 2008 Product Catalogue

G50/AG150/GB50 Controller Web Screenshots

Login

Access to the web pages is secured using a customisedusername and password.

Monitor Air Conditioning - Overview

The first screen allows you to monitor all the units connected to theG50/AG150/GB50. Each icon displays On/Off, Faults and timer On/Off.

Monitor Air Conditioning - Block view

Each area of the building can be displayed with informationabout On/Off, Setpoint , Mode and Temperature.

Remote Controller Settings

Click on any icons in the Monitor View page to access theremote controller. Lossnay units can also be controlled. Buttons on the local controllers may be locked (On/Off, Mode, Setpoint, Filter Reset).

Daily, Weekly and Annual Scheduling (AS PIN code)

Scheduling may be set from the web pages. A night set back operation is available (Heat, 12ºC).Optional on the G50, standard on the AG150/GB50.

Monitor Fault Codes

Faults with the unit address can be displayed under fault conditions. Email status can also be shown.

Multiple Users (VRC PIN code)

If the G50/AG150/GB50 is connected to an office LAN, the staff will then be able to access the web pages. With VRC eachmember of staff will have their own username and password.

Multiple Users (VRC PIN code)

Installation costs will be reduced as no wall remotecontrollers will need to be purchased and installed.

New icons now available to suit model type installed

Page 231

Con

trol

sR

ange

200

8G

B50

Con

trol

ler

/ G

50/A

G15

0/G

B50

Web

Scr

eens

hots

Page 231: 2008 Product Catalogue

G50/AG150/GB50 Desktop Remote Controller

More and more customers are using the G50/GB50 controller directly from their computers, so Mitsubishi Electric haslaunched a new, even simpler alternative which presents the customer with what looks like a standard remote controllerinterface - on their PC desktop. Called the PAR-21PC, the new application can also be minimised in the Desktop Toolbar,just like other Windows applications, so that the customer can have immediate control with just one click of the mouse.

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA

ETHERNET

PAR-21PC Desktop Remote Controller

OPERATION PLATFORM

MAX No. OF INDOOR UNITS

ON/OFF

MODE SELECTION

TEMPERATURE SETTING

FAN SPEED SETTING

AIR FLOW DIRECTION

CLOCK DISPLAY

INDOOR RETURN AIR TEMPERATURE

ERROR INDICATION

TIMER OPERATION

FUNCTION

Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4or Windows Professional XP service pack 2 or Windows Vista

Up to 16 indoor units within a group

Run and Stop operation for a single group

Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems

Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C

4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi

Air Flow angles:100º-80º-60º-40º and auto swing

Displays the time on the desktop controller

Displays the measured intake temperature from each group

Displays a 4 digit code and the affected unit address.

Weekly. Maximum of 3 time sequences with 3 Start/Stop times per day for all groups can be allocated

DESCRIPTION

Technical Information

M-NET

PAC-SC50KUA

*NOTE 1

Page 232

Page 232: 2008 Product Catalogue

The new third party equipment interfaces allow the user to monitor and control third party equipment from the G50/GB50 web pages.

G50/AG150/GB50 Third Party Equipment Interfaces

*NOTE 1

FUNCTION

MAX No. OF INPUTS

MAX No. OF OUTPUTS

MAX No. OF EQUIPMENT

POWER SUPPLY

MONITOR

CONTROL

SIGNAL

DIMENSIONS - mm (WxDxH)

DESCRIPTION PAC-YG66DCA PAC-YG63MCA

Power supply required

Third Party Interfaces

From G50/GB50 web pages or TG2000

From G50/GB50 web pages or TG2000

Signal required to monitor and control equipment

2 x Digital

2 x Digital

2

-

-

-

-

-

-

24VDC

Run / Faults

On/Off

Volt free contact

200x45x120

2 x Analogue

24VDC

Temperature / Humidity

-

Temperature 4-20mA / 1-5V / 0-10V / Pt100Humidity 4-20mA / 1-5V / 0-10V

200x45x120

Technical Information

PAC-YG66DCA PAC-YG63MCA

General Equipment

Third party equipment can be monitored and controlledfrom the web pages.

Temperature / Humidity

Temperature and humidity can be monitored.

Trend Logging

Temperature and humidity can be recorded and displayed.

Temperature / Humidity Limit

Limit (high and low) can be set to trigger alarms via email.

ETHERNET

EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

Page 233

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUANOTE 2: Temperature Sensors and Humidity Sensors not supplied by MEUK G

50/A

G15

0/G

B50

Des

ktop

Rem

ote

Con

trol

ler

/G

50/A

G15

0/G

B50

Third

Par

ty E

quip

men

t In

terf

aces

Con

trol

sR

ange

200

8

Page 233: 2008 Product Catalogue

ETHERNET

PLC

Ving Card Ving Card Ving Card

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUANOTE 2: It may take up to 3 minutes to switch ON the indoor unit (this time depends on how many indoor units are connected to the PLC).

PLC-QSERIES-LSPD

MAX No. OF INDOOR UNITS

ON/OFF

MODE SELECTION

TEMPERATURE SETTING

PERMIT/PROHIBIT SETTING

OCCUPIED ROOM SETTING

UNOCCUPIED ROOM SETTING

COMPATIBILITY

DIMENSIONS - mm (WxDxH)

FUNCTION

Up to 200 indoor units

Run and Stop operation for a single group

Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems

Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C

Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated

ON, AUTO, 21ºC (Factory setting)

City Multi only

198x44x98

DESCRIPTION

Technical Information

M-NET

PAC-SC50KUA

*NOTE 1

If the temperature is below 16ºCthe PLC restarts the unit to ON,HEAT, 19ºC and stops the unit when the temperature has reached18ºC (Factory setting)

If the temperature is above 26ºCthe PLC restarts the unit to ON,COOL, 21ºC and stops the unit when the temperature has reached24ºC (Factory setting)

Page 234

G50/AG150/GB50 Programmable Logic Controller

The PLC controller allows a hotel (for example) to have more accurate control over its air conditioning. The PLC works in conjunction with the key card system installed in each bedroom in many hotels. When the room is occupied, the PLC will switch ON the unit and reset the air conditioning to predetermined settings (for instance AUTO, 21ºC). When the room is unoccupied, the PLC will monitor the temperature in the room. If the temperature is too low or too high, the PLC will restart the unit.

Page 234: 2008 Product Catalogue

TG2000 Software

M-NET

ETHERNET

PC Based Software PackageThe TG2000 centralised PC based graphical software package allows the operator to control and monitor up to a maximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning system via the G50/GB50 controller, allowing the operator the required functionality to control and monitor the complete air conditioning system from a central location.

Technical Information

PAC-SC50KUA

*NOTE 1

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA

TG2000 PC Based software that works in conjunction with G50/GB50 Controller

OPERATING PLATFORM

MAX No. OF INDOOR UNITS

OPERATIONAL SECTIONS

ON/OFF

OPERATION MODE

SET TEMPERATURE

AIR SPEED

REMOTE CONTROLLERPROHIBIT/PERMIT

ABNORMALITY (FAULT) MONITORING

ROOM TEMPERATURE MONITORING

SCHEDULED ON/OFF

ENERGY SAVE CONTROL

TREND LOGGING

GRAPHICAL SCREENS

EMAIL

FUNCTION

Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista

2000 Indoor units, 50 indoor units per G50/AG150/GB50

The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration

Indicates the On/Off status of each group within the selected graphical screen or entire building

Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen

Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode

Displays the current fan speed setting for each group on the selected graphical screen

Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen

Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code

Displays the return air temperature of the master indoor unit within a group

On/Off schedules can be set for each group, each graphical screen or the entire building

Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional)

Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit, watt-hour meter and then email to customer

The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located

The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history

DESCRIPTION

Page 235

Con

trol

sR

ange

200

8G

50/A

G15

0/G

B50

Prog

ram

mab

le L

ogic

Con

trol

ler

/T

G20

00 S

oftw

are

Page 235: 2008 Product Catalogue

TG2000 Software with Energy Monitoring

M-NET

ETHERNET

PC Based Software PackageThe TG2000 centralised PC based graphical software package allows the operator to control and monitor up to amaximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning system viaG50/GB50 controller, allowing the operator all the required functionality to control and monitor the complete airconditioning system from a central location. In addition to providing a centralised control facility, the TG2000 allowscomplete energy consumption data to be logged with user definable billing groups and electrical tariffs for billing purposes.

Technical Information

PAC-SC50KUA

*NOTE 1

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUANOTE 2: Energy Meters not supplied by MEUK

TG2000 Software with Energy Monitoring

OPERATING PLATFORM

MAX No. OF INDOOR UNITS

OPERATIONAL SECTIONS

ON/OFF

OPERATION MODE

SET TEMPERATURE

AIR SPEED

REMOTE CONTROLLERPROHIBIT/PERMIT

ABNORMALITY (FAULT) MONITORING

ROOM TEMPERATURE MONITORING

SCHEDULED ON/OFF

ENERGY CHARGING

WEB REFRIGERANT STATUS CHECK

ENERGY CHARGING

ENERGY SAVE CONTROL

LOAD SHEDDING

TREND LOGGING

GRAPHICAL SCREENS

EMAIL

FUNCTION

Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4or Windows Professional XP service pack 2 or Windows Vista

2000 Indoor units, 50 indoor units per G50/AG150/GB50

The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation,monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration

Indicates the On/Off status of each group within the selected graphical screen or entire building

Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen

Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode

Displays the current fan speed setting for each group on the selected graphical screen

Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen

Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code

Displays the return air temperature of the master indoor unit within a group

On/Off schedules can be set for each group, each graphical screen or the entire building

Able to create or email bills for individual indoor units, groups of indoor units or a complete system (Optional) via the PAC-YG60MCA

Activate refrigerant volume checking function on Modular City Multi systems

Able to create bills for individual indoor units, groups of indoor units or a complete system (Optional)via the PAC-YG60MCA

Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional)

Activate energy saving mode when energy consumption is too high

Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit, watt-hour meter and then email to customer

The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located

The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history

DESCRIPTION

METER 1 METER 2 METER 3 METER 4

PAC-YG60MCA

Page 236

Page 236: 2008 Product Catalogue

M-NET

ETHERNET

PC Based Software PackageThe TG2000 centralised PC based graphical software package allows the operator to control and monitor up to a maximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning system via G50/GB50 controller, allowing the operator all the required functionality to control and monitor the complete air conditioning system from a central location. In addition to providing a centralised control facility, the TG2000 allows you to monitor and control third party equipment.

Technical Information

PAC-SC50KUA

*NOTE 1

PAC-YG66DCA PAC-YG63MCA

EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

TG2000 Software with Third Party Equipment

OPERATING PLATFORM

MAX No. OF INDOOR UNITS

OPERATIONAL SECTIONS

ON/OFF

OPERATION MODE

SET TEMPERATURE

AIR SPEED

REMOTE CONTROLLERPROHIBIT/PERMIT

ABNORMALITY (FAULT) MONITORING

ROOM TEMPERATURE MONITORING

SCHEDULED ON/OFF

ENERGY SAVE CONTROL

TREND LOGGING

GRAPHICAL SCREENS

THIRD PARTY EQUIPMENT MONITOR

THIRD PARTY EQUIPMENT CONTROL

EMAIL

FUNCTION

Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4or Windows Professional XP service pack 2 or Windows Vista

2000 Indoor units, 50 indoor units per G50/AG150/GB50

The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration

Indicates the On/Off status of each group within the selected graphical screen or entire building

Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen

Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode

Displays the current fan speed setting for each group on the selected graphical screen

Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen

Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code

Displays the return air temperature of the master indoor unit within a group

On/Off schedules can be set for each group, each graphical screen or the entire building

Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional)

Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit, watt-hour meter and then email to customer

The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located

Monitor general equipment Run and Faults via the PAC-YG66DCA interface and Temperature and Humidity via the PAC-YG63MCA

Control general equipment On/Off via the PAC-YG66DCA

The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history

DESCRIPTION

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUANOTE 2: Temperature and Humidity Sensors not supplied by MEUK

Page 237

TG2000 Software with Third Party Equipment

TG

2000

Sof

twar

e w

ith E

nerg

y M

onito

ring

/T

G20

00 S

oftw

are

with

Thi

rd P

arty

Equ

ipm

ent

Con

trol

sR

ange

200

8

Page 237: 2008 Product Catalogue

PC Based Software Package used to monitor and control multiple sitesThe TG2000 WAN centralised PC based graphical software package allows the operator to control and monitor upto a maximum of 1000 sites. Utilising the companies Wide Area Network, the complete (geographically distributed) air conditioning asset base can be controlled and monitored from a centralised location.

SITE 1(i.e. MANCHESTER)*NOTE 1

SITE 999(i.e. BIRMINGHAM)*NOTE 1

TG2000WAN (Wide Area Network) Software

OPERATING PLATFORM

MAX No. OF SITES

MAX No. OF INDOOR UNITS PER SITE

OPERATIONAL SECTIONS

ON/OFF

OPERATION MODE

SET TEMPERATURE

AIR SPEED

REMOTE CONTROLLERPROHIBIT/PERMIT

ABNORMALITY (FAULT) MONITORING

ROOM TEMPERATURE MONITORING

SCHEDULED ON/OFF

GRAPHICAL SCREENS

THIRD PARTY EQUIPMENT MONITORING

THIRD PARTY EQUIPMENT CONTROL

EMAIL

FUNCTION

Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista

1000

2000 Indoor units, 50 indoor units per G50/AG150/GB50 (per site)

The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation,monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration

Indicates the On/Off status of each group within the selected graphical screen or entire building

Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen

Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode

Displays the current fan speed setting for each group on the selected graphical screen

Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen

Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code

Displays the return air temperature of the master indoor unit within a group

On/Off schedules can be set for each group, each graphical screen or the entire building

The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located

Monitor general equipment Run and Faults via the PAC-YG66DCA interface and Temperature and Humidity via the PAC-YG63MCA

Control general equipment On/Off via the PAC-YG66DCA

The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history

DESCRIPTION

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUANOTE 2: The TG2000 WAN cannot be utilised if the following site functions are required: energy charging, energy saving and trend logging.NOTE 3: Temperature and Humidity Sensors not supplied by MEUK

Technical Information

PAC-YG66DCA PAC-YG63MCA

EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

PAC-YG66DCA PAC-YG63MCA

EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

WAN

Page 238

TG2000 WAN (Wide Area Network) Software

Page 238: 2008 Product Catalogue

TG2000 ScreenshotsDisplay Whole

The 2000 indoor units status may be shown on one screen.

Display Block

Block may be set for each area. Settings may bechanged by one click of the mouse for each area.

Display Floor

AutoCAD drawing may be imported to TG2000 to display floor screens.

Remote Controller Settings

Click on any icons in the floor view to access the remote controller settings. Buttons on the local controllers may be locked (On/Off, Mode, Setpoint, Filter reset).

Daily, Weekly and Annual Scheduling (AS PIN code)

Scheduling may be set from the TG2000. A night set back operation is available (HEAT, 12ºC). Optional on the G50, standard with the GB50.

Monitor Fault Codes

Faults with the unit address can be displayed underfault conditions.

Energy Monitoring (EC PIN code)

TG2000 in conjunction with energy meters can monitor the energy consumption for each outdoor unit, indoor unit or area. The indoor unit run hours can also be displayed.

Energy Saving (ES PIN code)

TG2000 offers different energy saving options including load shedding.

New icons now available to suit model type installed

TG

2000

WA

N /

TG

2000

Scr

eens

hots

Page 239

Con

trol

sR

ange

200

8

Page 239: 2008 Product Catalogue

BACnet® INTERFACEFUNCTION NETWORK VARIABLE NOTES

ControlOn/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Airflow Direction

Filter Sign

MonitorOn/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Airflow Direction

Fault Code

Filter Sign

Room Temperature

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

Horizontal - 60,80,100º swing

Normal/Reset

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

Horizontal - 60,80,100º swing

4 Character code - Indicates all unit alarms

-

-

ProconTM BAC-IP/50

BEMS BACnet® Interface

To further enhance our complete open system network offering, we offer a BACnet® gateway solution. Utilising the ASHRAE BACnet® standard, complete control and monitoring integration can be achieved with up to 50 air conditioning units.

BACnet® INTERFACEFUNCTION BAC-IP/50 COMPATIBLE WITH

MAX No. OFINDOOR UNITS

COMPATIBILITY

DIMENSIONS - mm(WxDxH)

50

City MultiMr Slim via PAC-SF80MAM Series via MAC-399IF

144x34x104

Andover Controls

York BMS

Siemens

Priva Building Intelligence

Delta Controls

Technical Information

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA

BAC-IP/50

ETHERNET PAC-SC50KUA

M-NET

*NOTE 1

Page 240

Page 240: 2008 Product Catalogue

ProconTM BAC-A/50

BEMS BACnet® Mr Slim Interface

A new BACnet® Interface has been specially developed for the Mr Slim systems. The BAC-A/50 cancontrol up to 50 individual systems.

Technical Information

BACnet® MR SLIM INTERFACEFUNCTION NETWORK VARIABLE NOTES

ControlOn/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Airflow Direction

Filter Sign

MonitorOn/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Airflow Direction

Fault Code

Filter Sign

Room Temperature

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

Horizontal - 60,80,100º swing

Normal/Reset

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

Horizontal - 60,80,100º swing

4 Character code - Indicates all unit alarms

-

-

BACnet® MR SLIM INTERFACEFUNCTION BAC-A/50 COMPATIBLE WITH

MAX No. OFOUTDOOR UNITS

COMPATIBILITY

DIMENSIONS - mm(WxDxH)

50

Mr Slim via PAC-SK81SI

270x75x210

Andover Controls

York BMS

Siemens

Priva Building Intelligence

Delta Controls

PAC-SK81SI

BAC-A/50

Con

trol

sR

ange

200

8

Page 241

BEM

S B

AC

net®

Inte

rfac

e /

BEM

S B

AC

net®

Mr

Slim

Inte

rfac

e

Page 241: 2008 Product Catalogue

BEMS LonWorks® Interface

The Mitsubishi Electric LMAP continues to strengthen the ability of our products to interface with other third partybuilding control systems using the globally recognised and accepted open network protocol Echelon LonWorks®.LonWorks® was introduced into the building services industry a number of years ago with the aim of establishingitself as the defacto communications standard. Many hundreds of products now exist that utilise the LonWorks®

protocol from complete systems like BEMS, lighting, power monitoring and security down to simple sensors and relay switches.

To ensure that our products can connect directly and easily with other LonWorks® products, the L-MAP02 was designed utilising Echelon MIPS technology and was the first to provide data in the LonWorks®

SNVT (Standard Network Variable Type) format.

LMAP

Technical Information

LMAP LonWorks® INTERFACEFUNCTION NETWORK VARIABLE NOTES

ControlOn/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Filter Sign

MonitorOn/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Fault Code

Filter Sign

Room Temperature

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint (only available when using PAC-YT51CRA or PAR-21MAA)

Normal/Reset

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint (only available when using PAC-YT51CRA or PAR-21MAA)

4 Character code - Indicates all unit alarms

-

-

LMAP LonWorks® INTERFACEFUNCTION LMAP COMPATIBLE WITH

MAX No. OFINDOOR UNITS

COMPATIBILITY

DIMENSIONS - mm(WxDxH)

50(G50/AG150/GB50 optional)

City MultiMr Slim via PAC-SF80MAM Series via MAC-399IF

340x60x360

Honeywell

Johnson Controls

Realtime Control Systems (LTX51/LTX21 via VCI)

Smart Controls

LMAP

M-NET

Page 242

Page 242: 2008 Product Catalogue

Technical Information

BEMS Modbus Interfaces

To further compliment the existing control and interface product ranges being offered by Mitsubishi Electricto support their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.

IP-32MIP-50MIP-100M

ProconTM IP-32M / IP-50M / IP-100M

ETHERNET PAC-SC50KUA

M-NET

MODBUS INTERFACE UNITS - OPERATIONAL INFORMATION

FUNCTION NETWORK VARIABLE MODBUS

ControlOn/Off Run/Stop

Mode Operation Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment Cooling 19-30˚C

Heating 17-28˚C

Auto 19-28˚C

Fan Speed Control Lo-Mi1-Mi2-Hi

MonitorOn/Off Run/Stop

Mode Operation Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment Cooling 19-30˚C

Heating 17-28˚C

Auto 19-28˚C

Fan Speed Control Lo-Mi1-Mi2-Hi

Fault Code 4 Character code – Indicates all unit alarms

Room Temperature -

MODBUS INTERFACESIP-50M IP-100M COMPATIBLE WITH

MAX No. OFINDOOR UNITS

COMPATIBILITY

DIMENSIONS - mm(WxDxH)

32

City MultiMr Slim via PAC-SF80MAM Series via MAC-399IF

270x75x210

50

City MultiMr Slim via PAC-SF80MAM Series via MAC-399IF

270x75x210

100

City MultiMr Slim via PAC-SF80MAM Series via MAC-399IF

270x75x210

Trend via Synapsys SXNC200CylonSatchwellCrestron (Home automation)InvensysInteractive HomesNorth BTAndoverSiemens

*NOTE 1

Modbus

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA

Page 243

Con

trol

sR

ange

200

8BE

MS

LonW

orks

®In

terf

ace

/BE

MS

Mod

bus

Inte

rfac

es

FUNCTION IP-32M

Page 243: 2008 Product Catalogue

BEMS Modbus Mr Slim Interface

To further compliment the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.

ProconTM A32M

Technical Information

MODBUS MR SLIM INTERFACE - OPERATIONAL INFORMATION

FUNCTION NETWORK VARIABLE MODBUS

ControlOn/Off Run/Stop

Mode Operation Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment Cooling 19-30˚C

Heating 17-28˚C

Auto 19-28˚C

Fan Speed Control Lo-Mi1-Mi2-Hi

MonitorOn/Off Run/Stop

Mode Operation Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment Cooling 19-30˚C

Heating 17-28˚C

Auto 19-28˚C

Fan Speed Control Lo-Mi1-Mi2-Hi

Fault Code 4 Character code – Indicates all unit alarms

Room Temperature -

MODBUS MR SLIM INTERFACEFUNCTION A32M COMPATIBLE WITH

MAX No. OFOUTDOOR UNITS

COMPATIBILITY

DIMENSIONS - mm(WxDxH)

32

Mr Slim via PAC-SK81SI

270x75x210

Trend via Synapsys SXNC200CylonSatchwellCrestron (Home automation)InvensysInteractive HomesNorth BTAndoverSiemens

PAC-SK81SI

A32M

Modbus

Page 244

NOTE: Not available on SEZ / SLZ

Page 244: 2008 Product Catalogue

BEMS Modbus Splits Interface

To further compliment the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.

ProconTM A1M

Technical Information

MODBUS SPLITS INTERFACE - OPERATIONAL INFORMATION

FUNCTION NETWORK VARIABLE MODBUS

ControlOn/Off Run/Stop

Mode Operation Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment Cooling 19-30˚C

Heating 17-28˚C

Auto 19-28˚C

Fan Speed Control Lo-Mi1-Mi2-Hi

MonitorOn/Off Run/Stop

Mode Operation Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment Cooling 19-30˚C

Heating 17-28˚C

Auto 19-28˚C

Fan Speed Control Lo-Mi1-Mi2-Hi

Fault Code 4 Character code – Indicates all unit alarms

Room Temperature -

MODBUS SPLITS INTERFACEFUNCTION A1M COMPATIBLE WITH

MAX No. OFINDOOR UNITS

COMPATIBILITY

DIMENSIONS - mm(WxDxH)

1

M SeriesMr Slim

72x27x50

Trend via Synapsys SXNC200CylonSatchwellCrestron (Home automation)InvensysInteractive HomesNorth BTAndoverSiemens

A1M

Modbus

Page 245

Con

trol

sR

ange

200

8BE

MS

Mod

bus

Mr

Slim

Inte

rfac

e /

BEM

S M

odbu

s Sp

lits

Inte

rfac

e

Page 245: 2008 Product Catalogue

BEMS KNX-EIB Interfaces

To further compliment the existing control and interface product ranges being offered by Mitsubishi Electricto support their air conditioning systems, the KNX-EIB range has been developed to accommodate the typical end-user needs as experienced within the UK market.

KNX-EIB-IP-15KNX-EIB-IP-100

ProconTM KNX-EIB-IP-15/100

ETHERNET PAC-SC50KUA

M-NET

KNX-EIB CITY MULTI INTERFACE UNITS - OPERATIONAL INFORMATION

FUNCTION NETWORK VARIABLE MODBUS

ControlOn/Off Run/Stop

Mode Operation Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment Cooling 19-30˚C

Heating 17-28˚C

Auto 19-28˚C

Fan Speed Control Lo-Mi1-Mi2-Hi

MonitorOn/Off Run/Stop

Mode Operation Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment Cooling 19-30˚C

Heating 17-28˚C

Auto 19-28˚C

Fan Speed Control Lo-Mi1-Mi2-Hi

Fault Code 4 Character code – Indicates all unit alarms

Room Temperature -

KNX-EIB CITY MULTI INTERFACESFUNCTION KNX-EIB-IP-15 KNX-EIB-IP-100 COMPATIBLE WITH

MAX No. OFINDOOR UNITS

COMPATIBILITY

DIMENSIONS - mm(WxDxH)

15

City MultiMr Slim via PAC-SF80MAM Series via MAC-399IF

107x58x105

100

City MultiMr Slim via PAC-SF80MAM Series via MAC-399IF

107x58x105

ABBIntelligent BuildingsNova Controls LtdSiemens

*NOTE 1

KNX-EIB

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA

Page 246

Technical Information

Page 246: 2008 Product Catalogue

BEMS KNX-EIB Splits Interface

To further compliment the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the KNX-EIB range has been developed to accommodate the typical end-user needs as experienced within the UK market.

ProconTM KNX-EIB-A-1

Technical Information

KNX-EIB SPLITS INTERFACE - OPERATIONAL INFORMATION

FUNCTION NETWORK VARIABLE MODBUS

ControlOn/Off Run/Stop

Mode Operation Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment Cooling 19-30˚C

Heating 17-28˚C

Auto 19-28˚C

Fan Speed Control Lo-Mi1-Mi2-Hi

MonitorOn/Off Run/Stop

Mode Operation Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment Cooling 19-30˚C

Heating 17-28˚C

Auto 19-28˚C

Fan Speed Control Lo-Mi1-Mi2-Hi

Fault Code 4 Character code – Indicates all unit alarms

Room Temperature -

KNX-EIB SPLITS INTERFACEFUNCTION KNX-EIB-A-1 COMPATIBLE WITH

MAX No. OFINDOOR UNITS

COMPATIBILITY

DIMENSIONS - mm(WxDxH)

1

M SeriesMr Slim

60x25x48

ABBIntelligent BuildingsNova Controls LtdSiemens

Page 247

KNX-EIB-A-1

KNX-EIB Con

trol

sR

ange

200

8BE

MS

KN

X-E

IB In

terf

aces

/

BEM

S K

NX

-EIB

Spl

its In

terf

ace

Page 247: 2008 Product Catalogue

M2M - OSM2M - ES

Optimised Start for Air ConditioningEnergy Saving Capability

M2M Software Options - Pin Code Activation

M2M INTERFACE - OPERATIONAL INFORMATION

FUNCTION NETWORK VARIABLE

ControlOn/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Airflow Direction

Filter Sign

MonitorOn/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Airflow Direction

Fault Code

Filter Sign

Room Temperature

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

Horizontal - 60,80,100º swing

Normal/Reset

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

Horizontal - 60,80,100º swing

4 Character code - Indicates all unit alarms

-

-

NOTESUP TO 25 GROUPS UP TO 50 GROUPS

M2M - Machine 2 Machine Interface

To offer remote management of its air conditioning units to companies with large numbers of dispersed offices, Mitsubishi Electric has adopted the M2M platform. The machine-to-machine (M2M) technology platform allows customers to integrate multiple sites into one network. The air conditioning units as well as third party equipmentwill be wirelessly connected to the M2M server and use the GPRS network to communicate.

MEUK

M2M SERVER

Technical Information

M2M INTERFACEFUNCTION DESCRIPTION

MAX No. OF INPUTS

MAX No. OF OUTPUTS

MAX No. OF INDOOR UNITS

COMPATIBILITY

DIMENSIONS - mm (WxDxH)

22 (4 to 20mA, 0 to 10VDC, 10kΩ resistor, digital)

4 (volt free contact)4 (pulse with modulation)

50

City Multi, Mr Slim and M Series

300x70x350

ProconTM Maxi M2M-IP/50

Page 248

GPRS

Maxi M2M-IP/50 GB50

DEMONSTRATIONVisit m2m.mitsubishielectric.co.uk/demo to use the live demonstration space (login: demo / password: demo)

METER 1 METER 2 METER 3 METER 4 EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

Maxi M2M-IP/50 GB50

METER 1 METER 2 METER 3 METER 4 EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

Page 248: 2008 Product Catalogue

M2M - OSM2M - ES

Optimised Start for Air ConditioningEnergy Saving Capability

M2M Software Options - Pin Code Activation DEMONSTRATIONVisit m2m.mitsubishielectric.co.uk/demo to use the live demonstration space (login: demo / password: demo)

To offer remote management of its air conditioning units to companies with large numbers of dispersed offices,Mitsubishi Electric has adopted the M2M platform. The machine-to-machine (M2M) technology platform allowscustomers to integrate multiple sites into one network. The air conditioning units as well as third party equipment will be wirelessly connected to the M2M server and use the GPRS network to communicate.

Con

trol

sR

ange

200

8

Page 249

M2M SPLITS INTERFACE - OPERATIONAL INFORMATION

FUNCTION NETWORK VARIABLE NOTES

ControlOn/Off Run/Stop

Mode Operation Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment Cooling 19-30˚C

Heating 17-28˚C

Auto 19-28˚C

Fan Speed Control Lo-Mi1-Mi2-Hi

Time Zone Weekly scheduling available

MonitorOn/Off Run/Stop

Mode Operation Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment Cooling 19-30˚C

Heating 17-28˚C

Auto 19-28˚C

Fan Speed Control Lo-Mi1-Mi2-Hi

Fault Code 4 Character code – Indicates all unit alarms

Room Temperature -

Time Zone Weekly scheduling available

M2M SPLITS INTERFACEFUNCTION DESCRIPTION

MAX No. OF INPUTS

MAX No. OF OUTPUTS

MAX No. OF INDOOR UNITS

COMPATIBILITY

DIMENSIONS - mm (WxDxH)

8 (4 to 20mA, 0 to 10VDC, 10kΩ resistor, digital)

4 (pulse with modulation)

16

Mr Slim and M Series via Procon A1M

255x60x180

Technical Information

M2M

Inte

rfac

e /

M2M

Spl

its In

terf

ace

MEUK

M2M SERVER

GPRS

A1MMini M2M-A/16

METER 1 METER 2 METER 3 METER 4 EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

Mini M2M-A/16

METER 1 METER 2 METER 3 METER 4 EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

ProconTM Mini M2M-A/16

M2M - Machine 2 Machine Splits Interface

A1M

A1M A1M

Page 249: 2008 Product Catalogue

M2M-Machine 2 Machine Web Screenshots

MEUK Website

M2M is accessible using MEUK website.

Login

A username and password is required to monitorand control sites.

Monitor Active Alarms and Sites

All sites are listed with active alarm sites.

Status

A site can be selected to monitor each system.

Set Parameters

Indoor unit and third party equipment can becontrolled from the Website.

Reports

Reports can be generated for analysis.

Dashboard

G50/AG150/GB50 web pages are available forthe air conditioning units

Administration

Using the administration level, the phone numbers and email of each duty engineer may be set and activated.

Technical Information

Page 250

Page 250: 2008 Product Catalogue

G50 Control PanelsMitsubishi Electric can supply G50 control panels (surface or internally mounted). This allows easy installation.

M-NET

G50 Control Panel

G50 CONTROL PANELSMODEL No. OF G50 No. OF INDOOR UNITS ROUTER MOUNTED DIMENSIONS (WxDxH)

GP50PS1

GP50PS2

GP50PS3

GP50PS4

GP50PI1

GP50PI2

GP50PI3

GP50PI4

GP50PSR1

GP50PSR2

GP50PSR3

GP50PSR4

GP50PIR1

GP50PIR2

GP50PIR3

GP50PIR4

1

2

3

4

1

2

3

4

1

2

3

4

1

2

3

4

50

100

150

200

50

100

150

200

50

100

150

200

50

100

150

200

NO

NO

NO

NO

NO

NO

NO

NO

YES

YES

YES

YES

YES

YES

YES

YES

Surface

Surface

Surface

Surface

Internally

Internally

Internally

Internally

Surface

Surface

Surface

Surface

Internally

Internally

Internally

Internally

600x200x600

600x200x600

800x250x600

800x250x600

600x200x600

600x200x600

800x250x600

800x250x600

600x200x600

600x200x600

800x250x600

800x250x600

600x200x600

600x200x600

800x250x600

800x250x600

Technical Information

Page 251

Con

trol

sR

ange

200

8M

2M W

eb S

cree

nsho

ts /

G50

Con

trol

Pan

els

Page 251: 2008 Product Catalogue

Run / Standby Control PanelsThe run/standby panel allows one system to run one week and the other one to run the other week. If one system fails, the run/standby panel will start the other one. If the temperature is too high, the panel will also start the 2 systems and enable an audible alarm.

Run / StandbyControl Panel

Technical Information

RUN / STANDBY CONTROL PANELSMODEL No. OF SYSTEMS RUN STANDBY HIGH TEMP

PANEL_RS1

PANEL_RS2

PANEL_RS3

2

3

4

1

2

3

1

1

1

YES

YES

YES

ALARM

YES

YES

YES

DIMENSIONS (WxDxH)

400x210x600

500x210x700

500x210x700

Page 252

Page 252: 2008 Product Catalogue

Energy Monitoring Control PanelsEnergy monitoring is key to the compliance with Part L2. To perform energy monitoring; a lot of differentproducts are required. To optimise the time of installation, Mitsubishi Electric can now supply an energymonitoring panel with energy meter, current transformers, breakers and the interface to the Mitsubishi Electric communication network.

M-NET

Energy Monitoring Control Panel

FUNCTION

PANEL_EM100A

PANEL_EM200A

No. OF SYSTEMS

ENERGY MONITORING CONTROL PANELS

1

2

MAX RUNNING CURRENT (A)

100

200

DIMENSIONS (WxDxH)

600x210x800

600x210x800

Technical Information

Power Supply

Page 253

Con

trol

sR

ange

200

8R

un/S

tand

by C

ontr

ol P

anel

s /

Ener

gy M

onito

ring

Con

trol

Pan

els

Page 253: 2008 Product Catalogue

Split-System A2M InterfacesThe City Multi systems use advanced communication protocol called M-NET. The Split-Systems can be interfaced to M-NET, allowing compatibility with the main centralised controller (G50, AG150, GB50, TG2000). An A2M adapter would be required per outdoor unit for Mr Slim and per indoor unit for Mr Slim S Series or M Series indoor units.

FUNCTION

COMPATIBILITY

CONNECTION TO

MNET SETTINGS

DIMENSIONS - mm (WxDxH)

Mr Slim S Series / M Series Indoor Unit

Indoor Unit

Dip Switches

160x55x70

PAC-SF80MA

SPLIT-SYSTEM A2M INTERFACES

Mr Slim Outdoor Unit

Outdoor Unit

Rotary Switches

130x15x90

MAC-399IF

Technical Information

PAC-SF80MA

Con

trol

sR

ange

200

8Sp

lit-S

yste

m A

2M In

terf

aces

Page 254

Page 254: 2008 Product Catalogue

Mitsubishi Electric Partner ProgrammeOpen to all contractors - large or small - the Mitsubishi Electric Par tner Programme offers contractors atotally new and unique set of benefits. There are two categories within the programme - Accredited Installerand Business Solutions Partner - these levels being a straight-forward reflection of the Partner’sstage of growth, with all customers signing up to the programmes standards and committing to continued training and professional development.

For more information please contact your local sales office

Mitsubishi Electric Training OptionsMitsubishi Electric has four state-of-the-ar t training suites based at different locations around the countr y for your convenience.Providing training for all levels of exper tise, our courses are taught by experienced engineers, with a wealth of knowledge and are all CPD accredited.

For bookings please telephone 01707 278797

Systems marked with the ECA logo have an energy label of A or B, are registered on theEnergy Technology List and hence qualify for 100% first year enhanced capital allowances(whole system cost and ‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk

Nominal conditions cooling: indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.Nominal conditions heating: indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. Winter; indoor 21˚C DB; outdoor -1˚C WB.

Notes: Recommended fuse ratings given throughout this price list are based on British Standard (BS88).

the name Mitsubishi is synonymous with excellenceKnown the world over, Mitsubishi is a trusted global leaderassociated with a variety of products and services. Founded in1907, the company known today as Mitsubishi Electric, quicklyrose to the forefront of the air conditioning industry - a position we still enjoy today.

Unsurpassed air conditioning from Mitsubishi ElectricAir conditioning is an ideal way of controlling the air quality inside any building, large or small.Not only does it cool in the summer months but air conditioning can also heat, replacing traditionalheating systems. More and more people today are experiencing the benefits of comfortable working,living and leisure environments made possible with air conditioning. As market leaders, we prideourselves in providing high performance, competitive systems with low running costs.

Protecting the environmentMitsubishi Electric boasts an explicit commitment to sustainable business practices such as energy and resource efficiency, minimising ecological impacts of our products and reducing greenhouse gas emissions. We are the only manufacturer in the industry recognised by Portfolio 21 as one of the top five companies in the world for our sustainable environmental policy. All of our factories are also ISO 14001 registered, the international standard that specifies a process for controlling and improving a company's environmental performance and with the advent of our Green Gateway Initiative, we strive to constantly promote best practice.

The Forest Stewardship Council (FSC) is an international network promoting responsible management of the world's forest. The paper this catalogue is printed on supports the development of responsible forest management worldwide. The wood comes from FSC certified, well managed forests, company controlled sources and/or recycled material.

Page 255: 2008 Product Catalogue

2008 Product Catalogue

Telephone: 01707 282880Post Sales Technical Support / Spares and Warranty: 0870 3000 300

email: [email protected]

web: www.mitsubishielectric.co.uk/aircon

UNITED KINGDOM Mitsubishi Electric Europe Air Conditioning Systems DivisionTravellers Lane, Hatfield, Hertfordshire, AL10 8XB, England. General enquiries Telephone: 01707 282880 Fax: 01707 278674

IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland. Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531)

Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2008. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Company’s General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.

Printed in April 2008

SAP No. 214760

www.greengatewayinitiative.co.uk

Designed by Square Bear Ltd 01604 899099. Square Bear Ltd are committed to using FSC certified paper and printers, wherever possible.

The laminate used on this brochure is environmentally friendly, recyclable and biodegradable

Features Key

2008 Product CatalogueA comprehensive range of Air Conditioning Systems from Mitsubishi Electric