  • EGRESS WIDTH PER OCCUPANT CALCULATIONS (FULLY SPRINKLERED)

    FULL FLOOR TENANT Based Upon the 2012 IBC Code

    Sections 1005.3.1 and 1005.3.2

    STAIR DOOR WIDTH STAIR WIDTH

    INCHES / RATIO INCHES / RATIO

    EXIT #1: 34 0.15 227 STAIR #1: 44 0.2 220

    EXIT #2: 34 0.15 227 STAIR #2: 44 0.2 220

    TOTAL ALLOWED = 453 TOTAL ALLOWED = 440

    OCCUPANCY LOAD CALCULATIONS:

    Based upon the 2012 IBC Table 1004.1.2

    Floor Area of Tenant Space: Square Footage

    Total Floor Area: 22965 GSF

    Vertical Penetration: 1122 USF

    Mechanical/ Electrical: 337 USF

    Total Usable Tenant Space: 20475 USF

    Occupant Load

    USF / RATIO = TOTAL OCCUPANCY

    BUSINESS AREAS: 18128 100 182

    CONFERENCE/ ASSEMBLY AREAS: 1729 15 116

    STORAGE: 618 300 3

    LIBRARY/Exercise: 0 50 0

    CLASSROOM: 0 20 0

    TOTAL TENANT OCCUPANCY = 301

    1ST FLOOR MINIMUM NUMBER OF PLUMBING FACILITIES - Table 2902.1

    TYPE OF

    OCCUPANCY

    OCCUPANT LOAD

    (PER

    MALE/FEMALE)

    WATER CLOSETS

    LAVATORIES

    DRINKING

    FOUNTAINS

    (URINAL SEE SECTION

    419.2)

    MALE FEMALE MALE FEMALE

    BUSINESS 91 2.820 2.820 2.138 2.138 0.056

    1 PER 25 FOR THE FIRST 50;

    1 PER 50 THEREAFTER

    1 PER 40 FOR

    FIRST 80; 1 PER 80

    THEREAFTER

    1 PER 100

    STORAGE 2 0.020 0.020 0.020 0.020 0.004

    1 PER 100 1 PER 100

    1 PER 1000

    ASSEMBLY 58 0.464 0.892 0.290 0.290 0.232

    1 PER 125 1 PER 65 1 PER 200

    1 PER 500

    MECHANICAL 2 0.020 0.020 0.020 0.020 0.004

    1 PER 100 1 PER 100

    1 PER 1000

    TOTAL

    REQUIRED

    306 3.3240 3.7523 2.4675 2.4675 0.2964

    TOTAL

    PROVIDED

    4 4 3 4 2

    *Note: Male WC count reduced/modified by Urinal Count (replacing no more than

    1

    2

    of required WC)

    215'-4"

    / 3 = 7

    2'-0"

    38'-3" / 3 = 13'-0" 26'-3

    "

    58'-5"

    Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    MEP Engineer:

    1412 E

    ye S

    treet, N

    W W

    ashington, D

    C 20005

    Tel 2

    02.621.1000

    Fax 2

    02.621.1001

    Web

    w

    ww

    .otj.com

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

    GPI Greenman-Pedersen, Inc.530 Gaither Road, Suite 100Rockville, MD 20850Ph: 240.268.1820Fax: 240.268.1821

  • DOOR TYPE D3 DOOR TYPE D4

    DOOR TYPE D5

    DOOR TYPE D6

    DOOR TYPE D7

    MODERNFOLD OPERABLE PARTITIONS AT LARGE CONFERENCE - SEE SHEET A0.3 AND A0.4 FOR MORE INFORMATION

    DOOR TYPE D1

    DOOR TYPE D2

    ALUMINUM FRAME @ JAMB

    3" = 1'-0"

    J1

    ALUMINUM FRAME @ JAMB

    3" = 1'-0"

    J2

    CARPET TO LINOLEUM

    3" = 1'-0"

    T3

    CARPET TO CARPET

    3" = 1'-0"

    T1

    CARPET TO WOOD

    3" = 1'-0"

    T2

    Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    MEP Engineer:

    1412 E

    ye S

    treet, N

    W W

    ashington, D

    C 20005

    Tel 2

    02.621.1000

    Fax 2

    02.621.1001

    Web

    w

    ww

    .otj.com

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

    GPI Greenman-Pedersen, Inc.530 Gaither Road, Suite 100Rockville, MD 20850Ph: 240.268.1820Fax: 240.268.1821

    J3

    EZYJAMB FRAME @ JAMB

    3" = 1'-0"

    POCKET DOOR @ HEAD

    3" = 1'-0"

    H4

    POCKET DOOR @ JAMB

    3" = 1'-0"

    J4

  • THERMOSTAT

    LIGHT SWITCH AND PUSH BUTTON

    STROBE AND SECURITY OUTLET BOXES

    (MEASURE TO BOTTOM OF FIXTURE)

    ALIGN

    ELECTRICAL OUTLET

    TELEPHONE / DATA OUTLET

    CO2 SENSORS

    CARD READER

    COAT HOOK

    A DORMA Group Company

    WARNING!!!

    #17G SWITCH REQUIRED!

    STANDARD #17 SWITCH

    WILL NOT WORK!

    PLEASE CHECK SWITCH TYPE.

    362SR-D

    RS

    PANEL LAYOUT

    OP-01

    LARGE CONF. ROOM

    A DORMA Group Company

    362SR-D

    RS

    PANEL LAYOUT

    OP-01

    LARGE CONF. ROOM

    WARNING!!!

    #17G SWITCH REQUIRED!

    STANDARD #17 SWITCH

    WILL NOT WORK!

    PLEASE CHECK SWITCH TYPE.

    Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    MEP Engineer:

    1412 E

    ye S

    treet, N

    W W

    ashington, D

    C 20005

    Tel 2

    02.621.1000

    Fax 2

    02.621.1001

    Web

    w

    ww

    .otj.com

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

    GPI Greenman-Pedersen, Inc.530 Gaither Road, Suite 100Rockville, MD 20850Ph: 240.268.1820Fax: 240.268.1821

    G1

    BUTT GLAZING JOINT

    6" = 1'-0"

    G2

    GLAZING JAMB

    6" = 1'-0"

    G3

    GLAZING AT HEAD

    3" = 1'-0"

    G4

    FULL HEIGHT GLAZING AT BASE

    3" = 1'-0"

    NOTES:

    STROBES, LIGHT SWITCHES, AND ETC. DEVICES TO ALIGN AS SHOWN.

    ALL ADJACENT DEVICES TO BE GANGED UNDER THE SAME COVERPLATE WHENEVER

    FEASIBLE.

    GENERAL CONTRACTOR SHALL BE REQUIRED TO RELOCATE ITEMS AT NO ADDITIONAL COST

    TO TENANT, ARCHITECT OR BUILDING OWNER.

    ALL DEVICES AND COVERPLATES TO BE WHITE UNLESS NOTED OTHERWISE. COVERPLATES

    FOR ALL DEVICES MOUNTED IN MILLWORK, TILE, OR OTHER SPECIALTY FINISHES TO BE

    STAINLESS OR ALUMINUM. SEE ARCHITECTURAL AND MEP PLANS FOR FURTHER

    INFORMATION.

    MOUNT COAT HOOK ON WALL WHERE GLASS LITES IN DOORS PROHIBIT INSTALLATION OF

    COAT HOOKS ON DOOR. LOCATE COAT HOOK IN FIELD WITH ARCHITECT.

  • A DORMA Group Company

    PANEL PLAN

    A DORMA Group Company

    A DORMA Group Company

    A DORMA Group Company

    PLAN VIEW

    ELEVATION

    NOTES:

    NOTES:

    BRACKETS IN STACK:

    BRACKETS IN RUN:

    BRACKET REQUIREMENTS (EXCEPT AS NOTED):

    HEAVY DUTY

    HEAVY DUTY

    HINGED JAMB HINGED JAMBHINGED CENTER PANEL

    TYPE III

    POCKET DOOR

    OP-02

    SMALL CONF ROOMS

    PANEL ELEVATION - SIDE "L"

    ACO

    USTI-SEAL EN

    CO

    RE - PAIRED

    PAN

    EL

    PANEL ELEVATION

    OP-02

    SMALL CONF ROOMS

    SOSS HINGE PANEL JOINT JAMB

    EXPANDABLE PANEL W/ JAMB

    VERTICAL SECTION

    ACO

    USTI-SEAL EN

    CO

    RE - PAIRED

    PAN

    EL

    DETAIL SHEET

    OP-02

    SMALL CONF ROOMS

    ARCHITECT / GENERAL CONTRACTOR NOTES

    ACO

    USTI-SEAL EN

    CO

    RE - PAIRED

    PAN

    EL

    PANEL LAYOUT

    OP-02

    SMALL CONF ROOMS

    Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    MEP Engineer:

    1412 E

    ye S

    treet, N

    W W

    ashington, D

    C 20005

    Tel 2

    02.621.1000

    Fax 2

    02.621.1001

    Web

    w

    ww

    .otj.com

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

    GPI Greenman-Pedersen, Inc.530 Gaither Road, Suite 100Rockville, MD 20850Ph: 240.268.1820Fax: 240.268.1821

  • (REFER TO SHEET A0.2 FOR PARTITION TYPES)

    Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    MEP Engineer:

    1412 E

    ye S

    treet, N

    W W

    ashington, D

    C 20005

    Tel 2

    02.621.1000

    Fax 2

    02.621.1001

    Web

    w

    ww

    .otj.com

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

    GPI Greenman-Pedersen, Inc.530 Gaither Road, Suite 100Rockville, MD 20850Ph: 240.268.1820Fax: 240.268.1821

    1 DEMOLITION PLAN1/8" = 1'-0"

  • (REFER TO SHEET A0.0 FOR PROJECT SYMBOLS, ABBREVIATIONS, AND BUILDING INFORMATION)

    (REFER TO SHEET A0.3 FOR PARTITION TYPES)

    Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    MEP Engineer:

    1412 E

    ye S

    treet, N

    W W

    ashington, D

    C 20005

    Tel 2

    02.621.1000

    Fax 2

    02.621.1001

    Web

    w

    ww

    .otj.com

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

    GPI Greenman-Pedersen, Inc.530 Gaither Road, Suite 100Rockville, MD 20850Ph: 240.268.1820Fax: 240.268.1821

    1 CONSTRUCTION PLAN1/8" = 1'-0"

  • AV

    AV

    BF BFBF

    BF

    BF BF

    BF BF

    BFBF

    BF BF

    BF

    BF

    BF BF

    BF

    AVAV

    BF BF

    BF BF

    BF BF BF BF BF BF BF

    BF

    AVAV

    AV

    AV

    AV

    AV

    AV

    AV

    AV

    CR

    J

    CR

    AV

    BF

    BF

    APPLIANCE, EQUIP, AND PLUMBING FIXTURE SCHEDULE

    SYMBOL DESCRIPTION MANUFACTURER FINISH CATALOG NUMBER REMARKS

    REFRIGERATOR- FREEZER

    FRIGIDAIRE

    GALLERY

    STAINLESS STEEL FGHF2366PF

    23 CU. FT.

    COUNTER DEPTH

    UNDER-COUNTER REFRIGERATOR

    SUMMIT

    APPLIANCE

    STAINLESS STEEL FF433ESSSADA ENERGY STAR

    MICROWAVE GE STAINLESS STEEL PEB2060SMSS

    DISHWASHER ASKO STAINLESS STEEL D5624XXLS ENERGY STAR

    3/4 HP GARBAGE DISPOSAL LG

    SINK ELKAY STAINLESS STEEL ELUHAD2115

    FAUCET KOHLER CHROME K-6331

    COFFEE MAKER -- -- PROVIDED BY TENANT

    GC TO PROVIDE

    WATER LIINE

    ICE MAKER HOSHIZAKI STAINLESS STEEL C-101BAH-AD ENERGY STAR

    WATER FILTRATION -- PROVIDED BY TENANT

    GC TO PROVIDE

    WATER LIINE

    COPIER --

    WALL MOUNTED TV -- PROVIDED BY VENDOR

    AV RACK -- PROVIDED BY VENDOR

    DESKTOP PRINTER -- PROVIDED BY TENANT

    SECURITY CAMERA -- PROVIDED BY VENDOR

    MOTORIZED PROJECTOR SCREEN -- PROVIDED BY VENDOR

    CEILING MOUNTED PROJECTOR -- PROVIDED BY VENDOR

    MOTORIZED MECHA-SHADE BLINDS -- PROVIDED BY VENDOR

    CAMERA -- PROVIDED BY VENDOR

    REMARKS/ NOTES:

    Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    MEP Engineer:

    1412 E

    ye S

    treet, N

    W W

    ashington, D

    C 20005

    Tel 2

    02.621.1000

    Fax 2

    02.621.1001

    Web

    w

    ww

    .otj.com

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

    GPI Greenman-Pedersen, Inc.530 Gaither Road, Suite 100Rockville, MD 20850Ph: 240.268.1820Fax: 240.268.1821

    1 POWER AND SIGNAL PLAN1/8" = 1'-0"

  • TYPE DESCRIPTION LAMP MANUFACTURER FIXTURE NAME CATALOG # NOTES

    A 2X2 RECESSED LENSED T8 FOCAL POINT LUNA 2X2 FLU-22-B-2-BX40-E-120-G-PS-WH

    ALL DAYLIGHTHARVESTING

    FIXTURES 15'-0"FROM THE

    PERIMETER TO BEDIMMABLE

    B 8' LINEAR TECHZONE FOCAL POINT SEEM 4 FSM4L-FL-375LF-35K-LD1-WH-8'

    C 16' LINEAR TECHZONE FOCAL POINT SEEM 4 FSM4L-FL-375LF-35K-LD1-WH-4'

    D 4" ROUND DOWNLIGHT FOCAL POINT 4.5" APERTURE id FL4D-15LED-L35-RO-T-L4-RO-CDDIMMABLE ATRECEPTION

    E 10' LINEAR LIGHT FOCAL POINT SEEM 4 FSM4L-FL-375LF-35K-LD1-WH-10'

    F 12' LINEAR LIGHT FOCAL POINT SEEM 4 FSM4L-FL-375LF-35K-LD1-WH-6'

    G UNDERCABINET LIGHT LUMENSPULSE UDERCABINETTASK LIGHTLUCRO-24V-PERPLAN-30K

    -FR-WH

    H PENDANT USA LUMINATION NANOLED NXTPENDANTLNRP3-9020-M2-10-10-35K

    S-50-SOCC-SM-VOLTS NON-DIMMABLE

    I 4" ROUND WALL WASHER ZUMTOBEL BASYS CFL 4" BR4DCFL_FIF_330_VER_13W_DL

    SUBSTITUTIONS TO ANY LIGHT FIXTURES ARE SUBJECT TO THE TENANT ARCHITECT'S WRITTEN APPROVAL, AND SHOULD BE EQUAL IN APPEARANCE,FUNCTION, VOLTAGE, DIMMING, QUALITY OF CONSTRUCTION, ETC. TO THOSE LISTED IN THE SCHEDULE ABOVE. SUBSTITUTIONS TO ANY FIXTURES

    WILL NOT BE CONSIDERED ANY LATER THAN 5 BUSINESS DAYS PRIOR TO THE BID DUE DATE. SEE SPECIFICATIONS FOR SUBSTITUTION PROCEDUREREQUIREMENTS. SUBSTITUTIONS WITHOUT THE TENANT ARCHITECT'S WRITTEN APPROVAL ARE NOT PERMITTED.

    Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    MEP Engineer:

    1412 E

    ye S

    treet, N

    W W

    ashington, D

    C 20005

    Tel 2

    02.621.1000

    Fax 2

    02.621.1001

    Web

    w

    ww

    .otj.com

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

    GPI Greenman-Pedersen, Inc.530 Gaither Road, Suite 100Rockville, MD 20850Ph: 240.268.1820Fax: 240.268.1821

    1 REFLECTED CEILING PLAN1/8" = 1'-0"

  • FINISH SCHEDULE

    TAG MATERIAL MANUFACTURER MODEL NO. COLOR REMARKS NOTES

    B1RUBBER BASE

    B2WOOD BASE

    C1CARPET

    C2CARPET

    C3CARPET

    C4 CARPET

    G1GROUT

    GL1

    BACK PAINTED

    GLASS

    P1PAINT

    P2PAINT

    P3 PAINT

    P4PAINT

    PL1

    PLASTIC

    LAMINATE

    PL2

    PLASTIC

    LAMINATE

    PL3

    PLASTIC

    LAMINATE

    PL4

    PLASTIC

    LAMINATE

    PL5

    PLASTIC

    LAMINATE

    TP1TACK PANEL

    VCT1

    RESILIENT

    FLOORING

    VCT2

    RESILIENT

    FLOORING

    WD1WOOD FLOOR

    WF1WINDOW FILM

    SEE SPECIFICATIONS SHEETS FOR ADDITIONAL MATERIALS; SPECIFICATION REQUIREMENTS; AND SUSTAINABLE REQUIREMENTS

    MANUFACTURER'S REPRESENTATIVES:

    CARPETING

    CONTACT: Robin Wasserman - [email protected]

    WOOD FLOOR

    CONTACT: Hertog - [email protected]

    Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    MEP Engineer:

    1412 E

    ye S

    treet, N

    W W

    ashington, D

    C 20005

    Tel 2

    02.621.1000

    Fax 2

    02.621.1001

    Web

    w

    ww

    .otj.com

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

    GPI Greenman-Pedersen, Inc.530 Gaither Road, Suite 100Rockville, MD 20850Ph: 240.268.1820Fax: 240.268.1821

    1 FINISH PLAN1/8" = 1'-0"

  • ELEVATORS ELEVATION3/8" = 1'-0"1

    ELEVATORS ELEVATION3/8" = 1'-0"2

    ENTRANCE3/8" = 1'-0"3

    ENTRANCE3/8" = 1'-0"4

    FEATURE WALL / CONF. 705A-B3/8" = 1'-0"5

    MEDIUM CONFERENCE3/8" = 1'-0"6

    COFFEE BAR & DISPLAY 7133/8" = 1'-0"8 GRAPHIC WALL - RECEPTION3/8" = 1'-0"7

    OFFICE STORE FRONT - TYP3/8" = 1'-0"9

    REFRIGERATORFRIGIDAIRE - FGHN2844L F

    BY GC

    STAFF BREAKROOM 7173/8" = 1'-0"10

    STAFF BREAKROOM 7173/8" = 1'-0"11

    FEATURE WALL - LOUNGE3/8" = 1'-0"12

    Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    MEP Engineer:

    1412 E

    ye S

    treet, N

    W W

    ashington, D

    C 20005

    Tel 2

    02.621.1000

    Fax 2

    02.621.1001

    Web

    w

    ww

    .otj.com

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

    GPI Greenman-Pedersen, Inc.530 Gaither Road, Suite 100Rockville, MD 20850Ph: 240.268.1820Fax: 240.268.1821

  • LARGE CONF.3/8" = 1'-0"LARGE CONF. SEE DETAILS ON A0.33/8" = 1'-0"2 BENCH - LOUNGE 7183/8" = 1'-0"1

    LARGE CONF.3/8" = 1'-0"LARGE CONF. AV WALL3/8" = 1'-0"3MOTHERS ROOM 7323/8" = 1'-0"4

    PRINT / COPY 7403/8" = 1'-0"5

    PRINT / COPY 7553/8" = 1'-0"6

    EXEC. AREA 7573/8" = 1'-0"7

    Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    MEP Engineer:

    1412 E

    ye S

    treet, N

    W W

    ashington, D

    C 20005

    Tel 2

    02.621.1000

    Fax 2

    02.621.1001

    Web

    w

    ww

    .otj.com

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

    GPI Greenman-Pedersen, Inc.530 Gaither Road, Suite 100Rockville, MD 20850Ph: 240.268.1820Fax: 240.268.1821

  • 1

    9 SECTION AT REFRIGERATOR WITH CABINET ABOVE1 1/2" = 1'-0" 8SECTION AT MICROWAVE TOWER W/ TRASH1 1/2" = 1'-0" 6

    SECTION AT UPPER CABINETS 1 1/2" = 1'-0"

    COAT ROD AND SHELF DETAIL1 1/2" = 1'-0"14

    7 UNDERCOUNTER ADA REFRIDGERATOR DETAIL1 1/2" = 1'-0"

    13 ADJUSTABLE KV SHELVING TYP. 507C, 526B, 526C1 1/2" = 1'-0"

    2 SECTION AT BASE CABINET WITH PULLOUT1 1/2" = 1'-0"3 SECTION AT SINK BASE CABINET1 1/2" = 1'-0"SECTION AT COUNTER WITH APPLIANCE1 1/2" = 1'-0"45

    SECTION AT DRAWER CABINET1 1/2" = 1'-0"

    SECTION AT BASE CABINET WITH DOOR1 1/2" = 1'-0"

    10 SECTION AT REFRIGERATOR WITH CABINET ABOVE1 1/2" = 1'-0"

    12 SECTION AT CONF. ROOM AV CABINET1 1/2" = 1'-0" 11BASE CABINET DRAWER W/PLAM TOP DETAIL1 1/2" = 1'-0"

    Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    MEP Engineer:

    1412 E

    ye S

    treet, N

    W W

    ashington, D

    C 20005

    Tel 2

    02.621.1000

    Fax 2

    02.621.1001

    Web

    w

    ww

    .otj.com

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

    GPI Greenman-Pedersen, Inc.530 Gaither Road, Suite 100Rockville, MD 20850Ph: 240.268.1820Fax: 240.268.1821

  • 1 ACT TO GYP CEILING DETAIL3" = 1'-0"2GYP BULKHEAD TO ACT - CONFERENCE DETAIL3" = 1'-0"3

    GYP. SOFFIT TO GYP. CEILING DETAIL3" = 1'-0"4

    SECTION DETAIL AT MECHANICAL SHADE: CONFERENCE ROOM3" = 1'-0"

    6 GYP TO GYP3" = 1'-0"7DETAIL AT ACT CEILING AND EXPOSED CEILING3" = 1'-0"9

    DETAIL AT TECHZONE CEILING3" = 1'-0" 8

    DETAIL AT GYP CEILING AND EXPOSED CEILING3" = 1'-0"

    5 PANTRY BANQUETTE DETAIL1 1/2" = 1'-0"

    10 DETAIL AT MULLION3" = 1'-0"12DETAIL SECTION VIEW @ TYP. SHELF ASSEMBLY1 1/2" = 1'-0" 11

    SHELF - SECTION VIEW1 1/2" = 1'-0"

    Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    MEP Engineer:

    1412 E

    ye S

    treet, N

    W W

    ashington, D

    C 20005

    Tel 2

    02.621.1000

    Fax 2

    02.621.1001

    Web

    w

    ww

    .otj.com

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

    GPI Greenman-Pedersen, Inc.530 Gaither Road, Suite 100Rockville, MD 20850Ph: 240.268.1820Fax: 240.268.1821

  • Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    1412

    Eye

    Stre

    et,N

    WW

    ashi

    ngto

    n,D

    C20

    005

    Tel2

    02.6

    21.1

    000

    Fax2

    02.6

    21.1

    001

    Web

    ww

    w.o

    tj.co

    m

    2014 OTJ Architects, Inc.

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

  • Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    1412

    Eye

    Stre

    et,N

    WW

    ashi

    ngto

    n,D

    C20

    005

    Tel2

    02.6

    21.1

    000

    Fax2

    02.6

    21.1

    001

    Web

    ww

    w.o

    tj.co

    m

    2014 OTJ Architects, Inc.

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

  • Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    1412

    Eye

    Stre

    et,N

    WW

    ashi

    ngto

    n,D

    C20

    005

    Tel2

    02.6

    21.1

    000

    Fax2

    02.6

    21.1

    001

    Web

    ww

    w.o

    tj.co

    m

    2014 OTJ Architects, Inc.

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

  • Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    1412

    Eye

    Stre

    et,N

    WW

    ashi

    ngto

    n,D

    C20

    005

    Tel2

    02.6

    21.1

    000

    Fax2

    02.6

    21.1

    001

    Web

    ww

    w.o

    tj.co

    m

    2014 OTJ Architects, Inc.

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

  • Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    1412

    Eye

    Stre

    et,N

    WW

    ashi

    ngto

    n,D

    C20

    005

    Tel2

    02.6

    21.1

    000

    Fax2

    02.6

    21.1

    001

    Web

    ww

    w.o

    tj.co

    m

    2014 OTJ Architects, Inc.

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

  • Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    1412

    Eye

    Stre

    et,N

    WW

    ashi

    ngto

    n,D

    C20

    005

    Tel2

    02.6

    21.1

    000

    Fax2

    02.6

    21.1

    001

    Web

    ww

    w.o

    tj.co

    m

    2014 OTJ Architects, Inc.

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

  • Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    1412

    Eye

    Stre

    et,N

    WW

    ashi

    ngto

    n,D

    C20

    005

    Tel2

    02.6

    21.1

    000

    Fax2

    02.6

    21.1

    001

    Web

    ww

    w.o

    tj.co

    m

    2014 OTJ Architects, Inc.

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

  • Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    1412

    Eye

    Stre

    et,N

    WW

    ashi

    ngto

    n,D

    C20

    005

    Tel2

    02.6

    21.1

    000

    Fax2

    02.6

    21.1

    001

    Web

    ww

    w.o

    tj.co

    m

    2014 OTJ Architects, Inc.

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

  • Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    1412

    Eye

    Stre

    et,N

    WW

    ashi

    ngto

    n,D

    C20

    005

    Tel2

    02.6

    21.1

    000

    Fax2

    02.6

    21.1

    001

    Web

    ww

    w.o

    tj.co

    m

    2014 OTJ Architects, Inc.

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

  • Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    1412

    Eye

    Stre

    et,N

    WW

    ashi

    ngto

    n,D

    C20

    005

    Tel2

    02.6

    21.1

    000

    Fax2

    02.6

    21.1

    001

    Web

    ww

    w.o

    tj.co

    m

    2014 OTJ Architects, Inc.

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

  • Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    1412

    Eye

    Stre

    et,N

    WW

    ashi

    ngto

    n,D

    C20

    005

    Tel2

    02.6

    21.1

    000

    Fax2

    02.6

    21.1

    001

    Web

    ww

    w.o

    tj.co

    m

    2014 OTJ Architects, Inc.

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

  • Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    1412

    Eye

    Stre

    et,N

    WW

    ashi

    ngto

    n,D

    C20

    005

    Tel2

    02.6

    21.1

    000

    Fax2

    02.6

    21.1

    001

    Web

    ww

    w.o

    tj.co

    m

    2014 OTJ Architects, Inc.

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

  • Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    1412

    Eye

    Stre

    et,N

    WW

    ashi

    ngto

    n,D

    C20

    005

    Tel2

    02.6

    21.1

    000

    Fax2

    02.6

    21.1

    001

    Web

    ww

    w.o

    tj.co

    m

    2014 OTJ Architects, Inc.

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

  • Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    1412

    Eye

    Stre

    et,N

    WW

    ashi

    ngto

    n,D

    C20

    005

    Tel2

    02.6

    21.1

    000

    Fax2

    02.6

    21.1

    001

    Web

    ww

    w.o

    tj.co

    m

    2014 OTJ Architects, Inc.

    1111 19th STREET7th FLOORWASHINGTON, D.C. 20036

  • C

    B

    A

    1 2 3 4

    NEW FRAMEDGLASS OPERABLEPARTITION

    COLUMNCOLUMN

    COLUMN COLUMN

    SMALLCONFERENCE

    PARTITIONSTACK AREA

    1'-6"

    3'-0"

    TYP.

    (U.N

    .O.)

    INDICATES NEWHANGER RODS *TYP,)

    6"MIN.

    INDICATES EXISTINGCONC. COL. (TYP.)

    1'-6"3'-0"3'-0"3'-0"VIF.6"6"

    INDICATESNEW HANGERRODS (TYP.)NEW OPERABLE

    PARTITION

    EXISTING PT BEAM(SEE NOTES)

    1'-6"

    L2x2x14 AT EACHEND OF CONT. PL

    PARTITIONSTACK AREA

    1'-6"

    WIDTH OF EXISTP.T. BEAM (SEE"POST INSTALLEDANCHOR" NOTE-1THIS SHEET )

    SMALLCONFERENCE

    LARGECONFERENCE LOUNGE

    NEW OPERABLEPARTITION

    SIM.

    719 718

    706-A

    706-B

    NTS2

    S1.0SECTION - FOLDING PARTITION SUPPORT

    L4x4x14x0'-8"

    L2x2x14 BRACE, SEE PLAN

    PL 5 8"x11" WIDECONT, SEE PLAN

    B/ (E) 8TH FLCONC SLAB

    A325 3 4PL 5/8"x4x0'-8" LG

    VERI

    FYw/

    ARC

    H

    A325 3 4(UNO ON PLAN)

    CEILING MOUNT KIT. HGR BY MFRCOORD EL w/ ARCH

    11

    6" MIN COOKDINHTETHIS DIMENSIONw/ ATCH

    SCALE AT FULL SIZE 3 4"=1'-0"

    1' 0 1' 2' 3'3

    S1.0SECTION

    (2) HILTI KWIK BOLT TZ CS1

    21

    4" EMBED

    L4x4x14x0'-8"

    L2x2x14 BRACE,SEE PLAN

    6"MIN

    B/ (E) 8TH FLCONC SLAB

    A325 3 4

    8"MIN

    A325 3 4

    (2) 3 8COUPLED w/ 12BOLTS TZ CS w/ 3 14"EMBED, TYP. SEE PLANFOR SPCG

    CEILING MOUNT KIT. HGRBY MFR COORD EL w/ ARCH

    11

    TYP

    PL 5 8"x11" WIDECONT, SEE PLAN

    L2x2x14 BRACE,SEE PLAN

    S1.0

    NEW FOLDINGPARTITIONSUPPORT

    Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    R4D PARTITION1111 19th Street, NWSte. 200Washington, DC 20036

    14

    12

    E

    ye

    S

    tre

    et, N

    W W

    ash

    in

    gto

    n, D

    C 2

    00

    05

    Tel 2

    02

    .6

    21

    .1

    00

    0Fa

    x 20

    2.6

    21

    .1

    00

    1W

    eb w

    ww

    .o

    tj.co

    m

    MEP Engineer:GHT LIMITED1110 N GLEBE RD, #300ARLINGTON, VA 22201Ph: 703.243.1200

    SCALE AT FULL SIZE 14"=1'-0"

    4' 0 4' 8'1

    S1.0PARTIAL 7TH FLOOR PLAN

    GENERAL1. The applicable building code is 2012 IBC.2. Contractor is solely responsible for means and methods during the course of the work. Do not

    damage or endanger the structural integrity of the Work or Existing Structure.3. Use architectural drawings and drawings of other trades in conjunction with the structural drawings

    to properly perform the work.4. Contractor is responsible for coordinating between trades.5. Do not scale drawings.6. Field dimensions

    A. Verify all dimensions and accurately locate all existing columns, beams and other structuralmembers before beginning work or preparing shop drawings.

    EXISTING BUILDING/STRUCTURE NOTES11. Utmost care shall be exercised at all times when working on existing structural members to avoid

    impairing the carrying capacity of the existing structure.A. Should the Architect or Engineer determine that the carrying capacity of the existing structure

    has been impaired by, or as a result of, the operations of the Contractor, or is otherwise not inconformance with the contract documents, appropriate remedial work shall be required.

    B. Any damage resulting from the operations of the Contractor shall be repaired as directed by theOwner's representative at no additional cost to the Owner.

    2. Notify Architect and Engineer before cutting or removal of any part of the existing structure notindicated to be modified or demolished.

    STRUCTURAL STEEL1.

    2. Structural steel design is based on the Allowable Strength Design (ASD) and Load and ResistanceFactor Design (LRFD) methodology. All loads shown on drawings are unfactored (service) loads,unless noted otherwise.

    3. The structural steel detailer shall develop all elevations, plans, and sections without reproducingsame from the design drawings. Detailer shall adequately cross reference the structural drawings tothe satisfaction of the engineer. All shop drawings shall be submitted for review and reviewcomments incorporated prior to fabrication.

    4. Materials shall conform to the following:ASTM A36 Rods, angles and platesASTM A992 W and WT shapesASTM A325 High strength boltsAWS A5.1 E70XX Welding electrodesASTM A36 All other structural shapes

    5. Connections:A. Provide minimum weld sizes in accordance with AISC 360 Specification for Structural Steel

    Buildings.B. Electrodes shall be suited to grade and weldability of base metal.C. Use AWS certified welders for structural welding.D. Field cutting or burning of structural steel is prohibited.E. See architectural drawings for additional steel not shown on structural drawings.F. Where plates, angles or other miscellaneous members require welding (either field or shop) or

    slip-critical connections, mask connection surfaces prior to shop priming and touch-up withprimer after completing connection.

    G. Provide adjustable connections for all members designated as AESS to facilitate adjustment toachieve the specified tolerance.

    POST-INSTALLED ANCHORS1. Utmost care shall be exercised when drilling for the anchor installation to avoid impairing the

    tendons or any other reinforcement of the existing concrete slab. Do not drill the existing concretebeam for any reason. Contractor shall conduct non-destructive testing of slab affected by the newwork, to locate such reinforcement prior to drilling for anchor installation or performing any coredrilling. Existing reinforcement shall not be cut, notched or otherwise compromised during thecourse of the work.

    2. Contractor shall be solely responsible for means and methods during the course of the work. Do notdamage or endanger the structural integrity of the existing structure.

    3. Drill and install post-installed anchors according to manufacturer's printed installation instructionsand per manufacturer's on-site training.

    4. All post-installed anchors shall meet ICC-es compliance for each type of application.5. Expansion anchors in concrete shall be hilti kwik bolt TZ, or approved equal.6. Provide standard AISC holes in all steel members receiving post-installed anchors. If oversized

    holes are provided to ease installation of the anchors, a plate washer (1/4"x2"x2") with an AISCstandard hole shall be installed and 1/8" fillet welded (all around) to the member.

    7. Testing: 10% of each type and size of drilled-in anchor shall be proof loaded by the independenttesting laboratory. Adhesive anchors and capsule anchors shall not be torque tested unlessotherwise directed by the engineer. If any of the tested anchors fail to achieve the specified torqueor proof load within the limits as defined in the drawings, all anchors of the same diameter and typeas the failed anchors shall be tested, unless otherwise instructed by the engineer.A. Perform tension testing in accordance with ASTM E488.B. Apply torque with a calibrated torque wrench.

  • GENERAL NOTES:

    1. ANALYSIS PROCEDURE PER ASCE 7-10 APPENDIX 11B.3, SEISMIC REQUIREMENTS FOR NEW STRUCTURES DOES NOT APPLY

    *PER GENERAL NOTES ON SHEET S1AND PLAN NOTES ON SHEETS S7FROM STRUCTURAL DRAWINGSSUBMISSION "CONSTRUCTION -MKJ" DATED APRIL 13, 1972 BYMICHAEL K. JOHNS

    2. THE USE FOR THIS SPACE IS EXISTINGOFFICE. PER CURRENT ASCE 7, THE OFFICE LIVELOAD IS 50 PSF. WE HAVE REVIEWED THE EXISTINGFRAMING BASED ON THE DRAWINGS PRODUCED BYMICHAEL K. JOHNS DATED APRIL 13, 1972 AND CERTIFY THAT THE EXISTING FRAMING TO BE SUFFICIENT FOR PROPOSED WORK.

    C 2015 KEAST & HOOD CO.

    STRUCTURAL TESTING & INSPECTION PROGRAM NOTES:

    1. THE INTENTION OF THIS TABLE IS TO IDENTIFY THE CONSTRUCTION REQUIRING SPECIAL INSPECTION AS REQUIRED BY THE 2012INTERNATIONAL BUILDING CODE (IBC). EACH SPECIAL INSPECTOR IS RESPONSIBLE FOR JOB SPECIFIC ITEMS AS DEFINED INCHAPTER 17 OF THE IBC (AND IN ACCORDANCE WITH THE SPECIFICATIONS).

    2. INSPECTIONS OF FABRICATORS IS NOT REQUIRED IF THE FABRICATOR IS APPROVED IN ACCORDANCE TO IBC SECTION 1704.2.5AND CERTIFIES COMPLIANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS.

    3. THE ITEMS CHECKED WITH AN "X" SHALL BE INSPECTED IN ACCORDANCE WITH IBC CHAPTER 17 BY A CERTIFIED SPECIALINSPECTOR FROM AN ESTABLISHED TESTING AGENCY. FOR MATERIAL SAMPLING AND TESTING REQUIREMENTS, REFER TO THEMATERIAL SAMPLING AND TESTING SECTION OF THE PROJECT SPECIFICATIONS AND THE GENERAL NOTES. THE TESTINGAGENCY SHALL SEND COPIES OF ALL STRUCTURAL TESTING AND INSPECTION REPORTS DIRECTLY TO THE ENGINEER,CONTRACTOR AND BUILDING OFFICIAL. ANY CONSTRUCTION WHICH FAILS TO MEET THE PROJECT SPECIFICATIONS AND IBCREQUIREMENTS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE CONTRACTOR FOR CORRECTION AND THEENGINEER IF UNCORRECTED. SPECIAL INSPECTION TESTING REQUIREMENTS APPLY EQUALLY TO ALL BIDDER DESIGNEDCOMPONENTS.

    4. FREQUENCY OF INSPECTIONS

    A. CONTINUOUS SPECIAL INSPECTION MEANS THAT THE SPECIAL INSPECTOR SHALL BE ON SITE AT ALL TIMES OBSERVING THEWORK REQUIRING SPECIAL INSPECTION. FOR STRUCTURAL STEEL, INSPECTION TASK MUST BE COMPLETED FOR EACHMEMBER OR CONNECTION.

    B. PERIODIC SPECIAL INSPECTION MEANS THAT THE SPECIAL INSPECTOR IS ON THE SITE AT THE TIME INTERVALS NECESSARYTO CONFIRM THAT ALL WORK REQUIRING SPECIAL INSPECTIONS IS IN COMPLIANCE. OPERATIONS NEED NOT BE DELAYEDPENDING THESE INSPECTIONS.

    5. ALL WELDS SHALL BE VISUALLY INSPECTED BY AN AWS CERTIFIED WELDING INSPECTOR. ALL PROVISIONS OF AWS D1.1/D1.1M"STRUCTURAL WELDING CODE - STEEL" SHALL APPLY TO STEEL CONSTRUCTION. NON-DESTRUCTIVE TESTING OF WELDEDJOINTS SHALL BE IN ACCORDANCE WITH AISC 360 SECTION N5.

    SPECIAL INSPECTIONS PROGRAM - STEEL CONSTRUCTION OTHER THAN STRUCTURAL STEEL

    VERIFICATION AND INSPECTION CONTINUOUS PERIODIC2012 IBC

    REFERENCESECTION

    REFERENCESTANDARD COMMENTS

    GENERAL INSPECTION OF FABRICATORS X 1704.2.5 SEE NOTE 2.

    SPECIAL INSPECTIONS PROGRAM - STRUCTURAL STEEL (AISC 360 CHAPTER N)

    VERIFICATION AND INSPECTION CONTINUOUS PERIODIC2012 IBC

    REFERENCESECTION

    AISC 360REFERENCE COMMENTS

    GENERAL INSPECTION OF FABRICATORS X 1704.2.5 SEE NOTE 2.

    DOCUMENT ACCEPTANCE OR REJECTION OF INSPECTED ITEMS X TABLES N5.4-3,N5.6-3, N6.1

    ANCHOR RODS,EMBEDMENTS,ANDPOST-INSTALLEDANCHORS

    PLACEMENT OF ANCHOR RODS AND OTHER EMBEDMENTSSUPPORTING STRUCTURAL STEEL SECTION N5.7

    VERIFY DIAMETER, GRADE, TYPE AND LENGTH OF THE ANCHOR RODOR EMBEDDED ITEM SECTION N5.7

    VERIFY EXTENT OR DEPTH OF EMBEDMENT INTO CONCRETE PRIOR TOCONCRETE PLACEMENT SECTION N5.7

    INSPECTION OFSTEEL FRAMEJOINT DETAILSFOR COMPLIANCEw/CONSTRUCTIONDOCUMENTS

    DETAILS SUCH AS BRACING & STIFFENING X SECTION N6

    MEMBER LOCATIONS X SECTION N6

    APPLICATION OF JOINT DETAILS AT EACH CONNECTION X SECTION N6

    PRIOR TOWELDING WELDING PROCEDURE SPECIFICATIONS (WPSs) AVAILABLE X TABLE N5.4-1

    MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLESAVAILABLE X TABLE N5.4-1

    MATERIAL IDENTIFICATION (TYPE/GRADE) X TABLE N5.4-1

    FIT-UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY) - JOINT PREPARATION - DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL) - CLEANLINESS (CONDITION OF STEEL SURFACES) - TACKING (TACK WELD QUALITY AND LOCATION) - BACKING TYPE AND FIT (IF APPLICABLE)

    X TABLE N5.4-1

    CONFIGURATION AND FINISH OF ACCESS HOLES X TABLE N5.4-1

    FIT-UP OF FILLET WELDS - DIMENSIONS (ALIGNMENT, GAPS AT ROOT) - CLEANLINESS (CONDITION OF STEEL SURFACES) - TACKING (TACK WELD QUALITY AND LOCATION)

    X TABLE N5.4-1

    DURING WELDINGUSE OF QUALIFIED WELDERS X TABLE N5.4-2

    INSPECTOR TO OBTAIN COPY OFWELDER CERTIFICATIONS PRIOR TOSTART OF WORK

    CONTROL AND HANDLING OF WELDING CONSUMABLES - PACKAGING - EXPOSURE CONTROL

    X TABLE N5.4-2

    NO WELDING OVER CRACKED TACK WELDS X TABLE N5.4-2

    ENVIRONMENTAL CONDITIONS - WIND SPEED WITHIN LIMITS - PRECIPITATION AND TEMPERATURE

    X TABLE N5.4-2

    WPS FOLLOWED - SETTINGS ON WELDING EQUIPMENT - TRAVEL SPEED - SELECTED WELDING MATERIALS - SHIELDING GAS TYPE/FLOW RATE - PREHEAT APPLIED - INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.) - PROPER POSITION (F, V, H, OH)

    X TABLE N5.4-2

    WELDING TECHNIQUES - INTERPASS AND FINAL CLEANING - EACH PASS WITHIN PROFILE LIMITATIONS - EACH PASS MEETS QUALITY REQUIREMENTS

    X TABLE N5.4-2

    AFTER WELDING WELDS CLEANED X TABLE N5.4-3

    SIZE, LENGTH AND LOCATION OF WELDS X TABLE N5.4-3WELDS MEET VISUAL ACCEPTANCE CRITERIA - CRACK PROHIBITION - WELD/BASE-METAL FUSION - CRATER CROSS SECTION - WELD PROFILES - WELD SIZE - UNDERCUT - POROSITY

    X TABLE N5.4-3

    ARC STRIKES X TABLE N5.4-3k-AREA INSPECTION AT DOUBLER PLATES, CONTINUITY PLATES, ORSTIFFENER PLATES X TABLE N5.4-3

    BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED) X TABLE N5.4-3

    REPAIR ACTIVITIES X TABLE N5.4-3

    PRIOR TOBOLTING

    MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENERMATERIALS X TABLE N5.6-1

    FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS X TABLE N5.6-1

    PROPER FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE,BOLT LENGTH IF THREADS ARE TO BE EXCLUDED FROM SHEAR PLANE) X TABLE N5.6-1

    PROPER BOLTING PROCEDURE SELECTED FOR JOINT DETAIL X TABLE N5.6-1

    CONNECTING ELEMENTS, INCLUDING THE APPROPRIATE FAYINGSURFACE CONDITION AND HOLE PREPARATION, IF SPECIFIED, MEETAPPLICABLE REQUIREMENTS

    X TABLE N5.6-1

    PRE-INSTALLATION VERIFICATION TESTING BY INSTALLATIONPERSONNEL OBSERVED AND DOCUMENTED FOR FASTENERASSEMBLIES AND METHODS USED

    X TABLE N5.6-1

    PROPER STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS ANDOTHER FASTENER COMPONENTS X TABLE N5.6-1

    DURING BOLTINGFASTENER ASSEMBLIES, OF SUITABLE CONDITION, PLACED IN ALLHOLES AND WASHERS (IF REQUIRED) ARE POSITIONED AS REQUIRED X TABLE N5.6-2

    JOINT BROUGHT TO THE SNUG-TIGHT CONDITION PRIOR TO THEPRETENSIONING OPERATION X TABLE N5.6-2

    FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTEDFROM ROTATING X TABLE N5.6-2

    FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSCSPECIFICATION, PROGRESSING SYSTEMATICALLY FROM THE MOSTRIGID POINT TOWARD THE FREE EDGES

    X TABLE N5.6-2

    3. SUPPORT HANGER SYSTEM DESIGNED TO SUPPORT 12" THICK GLASS PARTITION WALL AND GLASS DOOR SYSTEM FOR BOTH A OPENED AND STACKED CONDITION. L/360 DEFLECTION LIMITATION WAS USED IN DESIGN OF HANGER SUPPORT SYSTEM.

    Drawing Scale

    ISSUES

    SEAL / SIGNATURE

    CLIENT

    CONSULTANTS

    SHEET NAME

    FILE INFORMATION

    Project No:Drawn By:Checked By:Date:

    R4D PARTITION1111 19th Street, NWSte. 200Washington, DC 20036

    14

    12

    E

    ye

    S

    tre

    et, N

    W W

    ash

    in

    gto

    n, D

    C 2

    00

    05

    Tel 2

    02

    .6

    21

    .1

    00

    0Fa

    x 20

    2.6

    21

    .1

    00

    1W

    eb w

    ww

    .o

    tj.co

    m

    MEP Engineer:GHT LIMITED1110 N GLEBE RD, #300ARLINGTON, VA 22201Ph: 703.243.1200

    S2.0

    DESIGN CRITERIA& SPECIAL

    INSPECTIONSPROGRAM

    20150330_Results 4 Develpment - Permit Arch Set2015 0330 Results for Development Mechanical - Peer Review201504400M0.030x42 Plan

    201504400M1.030x42 Plan

    201504400M2.030x42 Plan

    201504400M3.030x42 Plan

    2015 0330 Results for Development Plumbing - Peer Review201504400P0.030x42 Plan

    201504400P2.030x42 Plan

    2015 0330 Results for Development Electrical - Peer Review201504400E0.030x42 Plan

    201504400E1.030x42 Plan

    201504400E2.030x42 Plan

    201504400E3.030x42 Plan

    201504400E4.030x42 Plan

    201504400E5.030x42 Plan

    201504400E6.030x42 Plan

    201504400E7.030x42 Plan

    S1.0S2.0