aboutrocksensor · 2018-12-20 · aboutrocksensor rocksensor is a company specializing in the...
TRANSCRIPT
About Rocksensor
Rocksensor is a company specializing in the design andmanufacture of industrial automation equipment, especiallyhigh-precision pressure instruments, for industrial processcontrol, gas and liquid analysis and flow measurement
As a leader in automation technology in the industry,Rocksensor provides excellent products, technical servicesand support for automation control to customers around theworld Its products are exported to Germany, the Netherlands,Italy, Switzerland, Russia, Brazil, the United States,Singapore, Malaysia, Indonesia, South Korea and othercountries and regions
Solid and reliable, vitality creation, pursuit of excellence, andwin-win cooperation are the corporate culture of Rocksensor
With its internationally leading technology starting point andits solid technical foundation, Rocksensor constantlyinnovates design and sustainable development to createproducts with excellent performance, high quality and stablequality
Rocksensor is committed to serving the global intelligentindustry with the mission of “serving global customers,helping intelligent manufacturing and promoting the progressof the industry”
Catalog
1、Technical Background····················································································A1
2、Working Principle··························································································A2
3、Products Description······················································································A3
4、RP1001-CS Differential Pressure Level Transmitter················································1
5、RP1002-CS Gauge Pressure Transmitter (Static Pressure Level Transmitter)···············8
6、RP1002-DSH Sanitary Gauge Pressure Transmitter RP1003-DSH Sanitary Absolute
Pressure Transmitter·····················································································15
7、RT2001-Thermal Resistance Temperature Transmitter·········································· 19
8、RT2003-Thermal Resistance Temperature Transmitter·········································· 21
9、RT2004-Thermal Resistance Temperature Transmitter·········································· 23
10、RF3000-DP Differential Pressure Flow Transmitter··············································25
11、RF3100- mass flow meter·············································································· 19
12、Appendix: Process Connection······································································· 34
Sanitary Products Catalog Selection Samples
www.rocksensor.com A1 Shanghai Rocksensor Automation Co,Ltd
Technical BackgroundRocksensor is a technology research anddevelopment enterprise specializing in highprecision sensor and transmitter technologyresearchRocksensor is mainly engaged in the researchand development of high-precision siliconsensor core technology, the research ofproduction technology and the development andplanning of product solutions, and also providingproducts for the customers Processingcustomization and technical services (includingtechnical services including silicon sensortechnology development and consulting,product technology transfer, production processdesign, etc), Rocksensor has a strong technicalbackground, and many well-known Europeanresearch institutes or research groups (such as:The Swiss Federal Institute of Technology,EPFL, the IMT of the University of NEUCHATEL,Switzerland, the Northwestern PolytechnicalUniversity of Switzerland, and the SwissMicroelectronics Technology Center (CESM)have close cooperation, and the R&D yield andconversion rate are over 93% We have goodcooperation with many world leading sensors,instrumentation, automation equipment, micro-electronics and mechanical Europe companiesRocksensor has obtained in-depth technicalcooperation from well-known research institutesand well-known institutions in many sensorfields in the world At the same time, theRocksensor technology R&D team is led bysenior senior engineers in many industries, and
is equipped with automation and machineryProfessional engineering and technicalpersonnel in the fields of MEMS, electronics,software, etc The core technical staff of the R&Dteam are trained in the professional theory andoperation of the IZM Institute in Frankfurt,Germany, and have obtained the qualificationcertificate issued by the instituteRocksensor’s R&D and experimental equipmentis equipped with European advanced intelligentmanufacturing standards, which are provided byprofessional equipment suppliers such as theUnited Kingdom, Germany, Switzerland, theUnited States, and Japan, and ensure theadvanced nature of the equipment tools used bythe R&D teamStability, high performance and high precisionensure high reliability and high efficiency ofproduct development, and ultimately ensureexcellent performance, reliable quality andperfect technologyAt the same time, Rocksensor has also beenguided and assisted by the team of Swisstechnical experts in the laying of the productionline to ensure the high efficiency, excellent,stable and reliable output of Rocksensorproducts The products are always in the sameindustry leading level in technology and quality ,located in the forefront of the internationalRelying on leading international technologyoutput and cooperation such as Switzerland andGermany, as well as Rocksensor 's strong R&Dteam and strong hardware investment,Rocksensor will be your most trustworthy andreliable partner!
Sanitary Products Catalog Selection Samples
www.rocksensor.com A2 Shanghai Rocksensor Automation Co,Ltd
Working Principle
1 Differential Pressure / PressureTransmitterThe differential pressure/pressure transmittersinclude two functional modules:——Sensor module——Electronic adapter unit moduleThe sensor module is a whole-welded closedcavity, and the isolation diaphragm prevent themedium from touching the sensitive componentThe process pressure is transmitted to thepressure sensing main chip via the filling liquid,and the bridge resistance with the piezoresistiveeffect on the sensing chip follows As a result,the electronic adapter unit module acquires thesignal and converts it to a standard outputThe sensor module simultaneously collects thefield temperature for correcting the temperatureeffects of the pressure sensing master chip Thedifferential pressure sensor module also collectsfield line pressure for correcting static pressureeffects The precise overload protection structureeffectively isolates the damage of the measuringchip from the unidirectional process pressurethat may exist in the fieldApplicable product models:RP1001-CS,RP1002-CS,RP1002-DSH,RP1003-DSH
2 Thermal Resistance TemperatureTransmitterThe RTD temperature transmitter consists oftwo functional modules:——Sensor module (PT100, Class A)——Temperature transmission moduleWhen the sensor module senses the fieldtemperature, the resistance value changes, andthe resistance value changes with temperaturechange The temperature transmission modulecollects signals and converts it into a standard
signal outputApplicable product models: RT2001-, RT2003-,RT2004-
3 Differential Pressure FlowmeterThe differential pressure flow meter includestwo functional modules:——Sensor module——Transmitter moduleThe differential pressure flowmeter adopts theunique technology of directly using the sensorbody as a throttling element When the fluidflows through the throttling device, a pressuredifference (P1-P2) is generated before and afterthe throttling device, and the pressure differencehas a certain functional relationship with the flowrate The transmitter module collects this signaland converts it into a standard signal outputApplicable product model: RF 3000
4 Mass Flow MeterThe mass flow meter consists of two functionalmodules:——Sensor module——Transmitter moduleThe mass flow meter uses a fluid in a linearmotion while in a rotating system, producing aCoriolis force principle proportional to the massflowThe sensor module consists of a thin-walledmeasuring tube and a vibration driver that arefixed at both ends to replace the rotation by thevibration, so that the fluid in the pipe generatesCoriolis force The transmitter module capturesthis signal and converts it to a standard signaloutputApplicable product model: RF 3100
Sanitary Products Catalog Selection Samples
www.rocksensor.com A3 Shanghai Rocksensor Automation Co,Ltd
Products Description1. RP1001-CS differential pressure leveltransmitter(Differential Pressure Level Meter) Measuring medium: gas, liquid Measuring parameters: pressure, liquid level Measurement range: 0 ~ 250kPa (0 ~ 25bar) Measuring Accuracy: ±01% Medium Temperature:-30~250℃ Wetted Diaphragm Material:316L、Titanium alloy
2. RP1002-CS gauge pressure transmitter(static pressure level meter) Measuring medium: gas, liquid Measuring parameters: pressure, liquid level Measuring range: 0~10MPa(0~100bar) Measuring Accuracy: ±01% Medium Temperature: -30~250℃ Wetted Diaphragm Material: 316L、Titanium alloy
3. RP1002-DSH Sanitary Gauge Pressure TransmitterRP1003-DSH Sanitary Absolute Pressure Transmitter
Measuring medium: gas, liquid Measuring parameters: pressure, liquid level Measuring range: -01~10MPa(-1bar~100bar) Measuring Accuracy: ±025% Medium Temperature: -30~200℃ Wetted Diaphragm Material: 316L、Titanium alloy
4. RT2001-Thermal resistance temperature transmitter Measuring medium: gas, liquid Measuring parameters: Temperature Measuring range: -50~200℃ Measuring Accuracy: ±02℃、±05℃ Wetted Diaphragm Material: 316L、Titanium alloy
Sanitary Products Catalog Selection Samples
www.rocksensor.com A4 Shanghai Rocksensor Automation Co,Ltd
5. RT2003-Thermal Resistance Temperature Transmitter Measuring medium: gas, liquid Measuring parameters: Temperature Measuring range: -10~150℃ Measuring accuracy: ±05℃ Wetted Diaphragm Material: 316L、Titanium alloy
6. RT2004-thermal resistance temperature transmitter Measuring medium: gas, liquid Measuring parameters: Temperature Measuring range: -50~200℃ Measuring accuracy: ±02℃、±05℃ Wetted Diaphragm Material: 316L、Titanium alloy
7. RF3000 differential pressure flowmeter Measuring medium: water Measuring parameters: flow Measuring range: 0~30T/h Measuring accuracy: ±05%、±1% Medium Temperature: -30~150℃ Display parameters: instantaneous flow, cumulative flow,
pressure,Temperature Wetted material: 316L
8. RP3100 Mass Flow Meter Measuring medium: Liquid Measuring parameters: flow Measuring range: 0~50T/h Measuring accuracy: ±015%、±02%、±05% Medium Temperature: -30~150℃ Wetted material: 316L, Hastelloy
RP1001-CS Differential Pressure Level Transmitter General Specifications Specifications Book
www.rocksensor.com 1 Shanghai Rocksensor Automation Co.,Ltd.
RP1001-CS Differential Pressure
Level Transmitter (Differential
Pressure Level Meter)
The RP1001-CS differential pressure leveltransmitter is used to measure the liquid leveland pressure of liquids and gases, and thenconvert it into a 4-20mADC HART current signaloutput. The RP1001-CS can communicate withthe RST375 handheld terminal or the RSM100Modem for parameter setting, processmonitoring, and more.
Standard Specification(Adjust the range based on the standard zeropoint, stainless steel 316L diaphragm, fillingfluid is silicone oil)
1 Performance SpecificationsReference Accuracy of Span Adjusting±0.1%(including nonlinearity,hysteresis and repeatability)If TD>10 (TD=maximumrange/adjustment range), it is:±(0.01×TD)%
Ambient temperature effectTotal Influence when -25℃~65℃:
±(0.3×TD+0.1)%×SpanTotal Influence when -40℃~-25℃And 65℃~85℃:
±(0.3×TD+0.1)%×Span
Overrange Influence±0.075%×Span
Stability±0.1%×Span /3 years
Power Supply Influence±0.001% /10V (12~36V DC)(It can be negligible)
2 Function SpecificationsSpan and RangeSpan&Range kPa Bar mH2O
BSpan 2~6 0.02~0.06 0.2~0.6
Range -6~0 -0.060~0 0~0.6
CSpan 4~40 0.04~0.4 0.4~4
Range -40~0 -0.4~0 0~4
DSpan 10~250 0.1~2.5 1~25
Range -250~0 -2.5~0 0~25
Relationship Between Minimum Range andProcess Connection PathNominal Diameter Minimum Span
DN40 10kPa
DN50 10kPa
DN80 2kPa
The Relationship Between Capillary Lengthand Process Connection PathCapillary Length m DN40 DN50 DN80
1 Y Y Y
2 Y Y Y
3 N Y Y
4 N Y Y
5 N N Y
6 N N Y
7 N N Y
8 N N Y
>8 N N N
Length Difference m 0 ≤1 ≤2
Note1:Capillary Length Recommend≤Liquid Level Height+1.
Note2:Capillary Length equals to be the length of ±chambers
Note3: "Y" is optional, and "N" is not optional.
RP1001-CS Differential Pressure Level Transmitter General Specifications Specifications Book
www.rocksensor.com 2 Shanghai Rocksensor Automation Co.,Ltd.
Zero SettingZero and span can be set any value within themeasurement range in the table, as long as:calibrated range ≥ minimum
Installation location InfluenceThe transmitter body can be fixed directly to anyposition. It is best to have the process flangeaxis in a vertical position and the positionaldeviation will produce a correctable zero offset.Capillary components and flanges should beinstalled as close as possible to the sameambient temperature. The minimum bendingradius of the capillary is 75mm, and winding isstrictly prohibited.
Output2 wires type, 4 to 20mADC output,HART communication.Output signal limit:Imin=3.9mA, Imax=20.5mA
Alarm CurrentUnderreport mode (minimum): 3.6mAOvertray mode (maximum): 21 mANo report mode (hold): Maintain the effectivecurrent value before the faultAlarm current standard setting: high-reportmode
Responding timeThe amplifier component has a dampingconstant of 0.1s; the sensor and the remoteflange time constant is 0.2 to 6s, it depends onthe sensor's range, turndown ratio, capillarylength, and viscosity of the fill fluid. Theadditional adjustable time constant is: 0.1 to 60s.
Preheat Time< 15s
Ambient Temperature-40~85℃
-20~65℃(with Backlit LCD Display)
Storage temperature / Transport temperature-50~85℃
-25~85℃(with Backlit LCD Display)
Medium Temperature-30~250℃Filling liquid, working temperature relationship sheet:Filling Fluid Silicon Oil(S) Vegetable Oil(V)
Density 25℃ 960kg/m3 937kg/m3
Work Temperature -30~250℃ 0~250℃
Pressure LimitFrom 3.5 kPa absolute pressure to ratedpressure.
One-way Overload limitThe low pressure side is the rated pressure ofthe transmitter body, and the high voltage sideis the rated pressure of the remote transmissionflange. There may be a correctable zero drift.
Electrical connections(EMC)Please check "Electromagnetic CompatibilitySchedule" on the next page.
Explosion Proof PerformanceNEPSI/ATEX Explosion-proof license:Ex dⅡC T6
NEPSI/ATEX Intrinsically safe license:Ex iaⅡC T4
The allowed temperature is:-40℃~65℃
3 InstallationPower and load conditionsPower Supply Voltage is 24VR≤(Us-12V)/Imax kΩImax=23 mAMaximum Power Supply:36VDCMinimum Power Supply:9VDC( low voltagetype),13.5VDC (backlit LCD display, OLEDdisplay)Digital communication load range: 230~600Ω
RP1001-CS Differential Pressure Level Transmitter General Specifications Specifications Book
www.rocksensor.com 3 Shanghai Rocksensor Automation Co.,Ltd.
Electrical ConnectionsM20X1.5 cable sealing buckle, terminal block issuitable for 0.5~2.5mm2 wire.
Process ConnectionStandard process connection: Tri-clampDN40/DN50/DN80 interface.
4 Physical Specifications MaterialDiaphragm: stainless steel 316L, Hastelloy C,titanium alloyProcess connection: stainless steel 316L
Filling liquid: silicone oil, vegetable oil,food grade filling liquidTransmitter housing:aluminum alloy, epoxycoated on the outside; stainlesssteel housing optional.Nameplate: Stainless steel 304
WeightAbout 10 to 16.5 kg
Housing Protect LevelIP67
Electromagnetic compatibility schedule
No. Test Items Basic Standard Test ConditionsFunction
Level
1 Radiation interference (housing)GB/T 9254-2008
Sheet530MHz~1000MHz Qualified
2Conducted interference
(DC power port)
GB/T 9254-2008
Sheet10.15MHz~30MHz Qualified
3Electrostatic discharge (ESD)
immunityGB/T 17626.2-2006
4kV(Contact)
8kV(Air)B
4Radio frequency electromagnetic
field immunityGB/T 17626.3-2006 10V/m (80MHz~1GHz) A
5Power frequency magnetic field
immunityGB/T 17626.8-2006 30A/m A
6Electrical fast transient burst
immunityGB/T 17626.4-2008 2kV(5/50ns,5kHz) B
7 Surge immunity GB/T 17626.5-2008
500V(Between lines)
1kV ( Between line and
Ground)(1.2us/50us)
B
8Radio frequency field induced
conducted interference immunityGB/T 17626.6-2008 3V(150KHz~80MHz) A
Note: (1) A performance level description: During the test, the performance is normal within the limits of the technical
specifications.
(2) B performance level description: During the test, the function or performance is temporarily reduced or lost,
but it can be recovered by itself, and the actual operating conditions, storage and data are not changed.
RP1001-CS Differential Pressure Level Transmitter General Specifications Specifications Book
www.rocksensor.com 4 Shanghai Rocksensor Automation Co.,Ltd.
External Dimensions unit(mm)
Horizontal piping installation method
Vertical piping installation method
RP1001-CS Differential Pressure Level Transmitter General Specifications Specifications Book
www.rocksensor.com 5 Shanghai Rocksensor Automation Co.,Ltd.
Wall Installation Method
5 Electronic Connection
Note: The shortcut interface function is equivalent to the signal terminal.
RP1001-CS Differential Pressure Level Transmitter General Specifications Specifications Book
www.rocksensor.com 6 Shanghai Rocksensor Automation Co.,Ltd.
6 Model and Specification code TableSanitary Differential Pressure Transmitter RP1001-
10 Accuracy
CS Basic Accuracy ±0.1%
20 Span
B 0-2kPa~6kPa /(0-200~600 mmH2O)
C 0-4kPa~40kPa /(0-400~4000 mmH2O)
D 0-10kPa~250kPa /(0-1~25 mH2O)
30 Diaphragm Material
S Stainless Steel 316L
C Hastelloy C
R Titanium alloy
40 Filling Fluid
A Silicon Oil
B Vegetable Oil
C Food grade filling Fluid
50 Process connection standard
A ASME BPE(default)
B ISO 2852
C DIN 32676
60 Process connection Size
2 Tri-clamp 1.5” / DN 40
3 Tri-clamp 2” / DN 50
5 Tri-clamp 3” / DN 80
70 Capillary Length
0 None
1 1m
2 2m
3 3m
4 4m
5 5m
6 6m
S Special Length
80 Mounting Bracket
N None
1 Stainless Steel
2 Galvanized carbon steel
90 Display Selection
N None
2 LCD Backlit Display(-20℃)
3 OLED Display(-40℃)
100 Explosion Proof
N Basic Type
A Intrinsically safe,NEPSI
D Explosion Proof,NEPSI
B Intrinsically safe,ATEX
RP1001-CS Differential Pressure Level Transmitter General Specifications Specifications Book
www.rocksensor.com 7 Shanghai Rocksensor Automation Co.,Ltd.
E Explosion Proof,ATEX
110 Tag Name Plate
N None
1 The number is marked on the nameplate
2 Hanging stainless steel signage
120 Document Requirement
N None
1 Test Report
2 Test Report + Cerification Report
130 Additional Options
S Stainless Steel Housing
Note 1: The RP1001-CS differential pressure level transmitter is equipped with a sanitary flange device in both the positive
and negative chambers
Option Example:Example: RP1001-CSCSAA3212NN2[CS] Basic error: ±0.1%
[C] Range: 0 to 40 kPa
[S] wetted part: stainless steel 316L diaphragm
[A] Filling Fluid: Silicone Oil
[A] Process Connection Standard: ASME BPE
[3] Process connection size: Tri-clamp 2"
[2] Capillary length: 2m
[1] Mounting bracket: stainless steel
[2] Display options: LCD backlit LCD display
[N] Explosion-proof: None
[N] tag: no
[2] Document Requirements: Test Report + Material Report
RP1002-CS Sanitary Gauge/Absolute Pressure Transmitter General Specifications Specifications Samples
www.rocksensor.com 8 Shanghai Rocksensor Automation Co.,Ltd.
RP1002-CS Gauge Pressure
Transmitter (Static Level
Transmitter)
The RP1002-CS sanitary Gauge/ AbsolutePressure Transmitter is used to measure thepressure of liquid or gas. It can also measurethe sanitary level of a liquid and then convertit to a 4-20 mADC HART current signal output.The RP1002 can communicate with theRST375 handheld terminal or the RSM100Modem for parameter setting, processmonitoring, and more.
Standard Specifications(Adjusting the range based on the standardzero point, stainless steel 316L diaphragm,filling fluid is silicone oil)
1 Performance SpecificationsReference Accuracy of Span Adjusting±0.1% (including nonlinearity,hysteresis and repeatability)If TD>10 (TD=maximum range/adjust range),it is: RP1002-CS: ±(0.01×TD)%
Ambient Temperature InfluenceTotal Influence when -25℃~65℃±(0.15×TD+0.05)%×SpanTotal Influence when -40℃~-25℃And 65℃~85℃±(0.2×TD+0.05)%×Span
Overrange Influence±0.075%×Span
Stability±0.1%×Span /3 years
Power Supply Influence±0.001% /10V (12~36V DC)(It can be negligible)
2 Functional SpecificationsSpan and RangeSpan/
RangekPa mH2O bar
BSpan 3~6 0.3~0.6 0.03~0.06
Range -6~6 -0.6~0.6 -0.06~0.06
CSpan 2~40 0.2~4 0.02~0.4
Range -40~40 -4~4 -0.4~0.4
DSpan 2.5~250 0.25~25 0.025~2.5
Range -100~250 -10~25 -1~2.5
FSpan 30~3000 3~300 0.3~30
Range -100~3000 -10~300 -1~30
The Relationship Between Capillary Lengthand Process Connection PathCapillary
Length mDN25 DN40 DN50 DN65 DN80
1 N Y Y Y Y
2 N Y Y Y Y
3 N N Y Y Y
4 N N Y Y Y
5 N N N Y Y
6 N N N N Y
>6 N N N N N
Note: "Y" is optional, and "N" is not optional.
RP1002-CS Sanitary Gauge/Absolute Pressure Transmitter General Specifications Specifications Samples
www.rocksensor.com 9 Shanghai Rocksensor Automation Co.,Ltd.
Zero SettingZero and span can be set any value within themeasurement range in the table, as long as:calibrated range ≥ minimum
Installation location InfluenceThe transmitter can be mounted directly throughthe chuck and the positional deviation willproduce a correctable zero offset. Transmitterwith capillary, it is recommended that thetransmitter be installed below the chuck position.If the chuck is lower than the transmitter body,the maximum adjustment drop between thechuck and the transmitter body should be ≤ 3m.When the working pressure is below 100 kPaabsolute pressure, the transmitter body must belower than the chuck. The minimum bendingradius of the capillary is 75mm, and winding isstrictly prohibited.
Output2 wires type, 4 to 20mADC output,HART communication.Output signal limit:Imin=3.9mA, Imax=20.5mA
Alarm CurrentUnderreport mode (minimum): 3.6mAOvertray mode (maximum): 21 mANo report mode (hold): Maintain theeffective current value before the faultAlarm current standard setting:high-report mode
Responding TimeThe amplifier component has a dampingconstant of 0.1s; the sensor and the remoteflange time constant is 0.2 to 6s, it depends onthe sensor's range, turndown ratio, capillarylength, and viscosity of the fill fluid. Theadditional adjustable time constant is: 0.1 to 60s.
Preheat Time< 15s
Ambient Temperature:-40~85℃
-20~65℃(with Backlit LCD Display)
Storage temperature / Transport temperature-50~85℃
-25~85℃(with Backlit LCD Display)
Medium Temperature:-30~150℃(without capillary);-30~250℃(with capillary);Filling liquid, working temperature relationship sheet
Filling Fluid Silicon Oil(S) Vegetable Oil(V)
Density 25℃ 960kg/m3 937kg/m3
Work Temp.Range -30~200℃ 0~250℃
Pressure LimitFrom Vacuum to maximum span.
Overload LimitSpan 40kPa 250kPa 3MPa
Overload Limit 1MPa 4MPa 15MPa
Electrical connections(EMC)Please check "Electromagnetic CompatibilitySchedule" on the next page.
Explosion Proof PerformanceNEPSI/ATEX Explosion-proof license:Ex dⅡC T6
NEPSI/ATEX Intrinsically safe license:Ex iaⅡC T4
The allowed temperature is:-40℃~65℃
3 InstallationPower and load conditionsPower Supply Voltage is 24V,R≤(Us-12V)/Imax kΩImax=23 mAMaximum Power Supply:36VDCMinimum Power Supply:9VDC (low voltagetype),13.5VDC (backlit LCD display, OLEDdisplay)Digital communication load range: 230~600Ω
RP1002-CS Sanitary Gauge/Absolute Pressure Transmitter General Specifications Specifications Samples
www.rocksensor.com 10 Shanghai Rocksensor Automation Co.,Ltd.
Electrical ConnectionsM20X1.5 cable sealing buckle, terminal block for0.5~2.5mm2 wire.
Process connection:DN25/DN40/DN50/DN65/DN80 Sanitary ConnectorZero Dead LDL (Line Dead Leg) interface.
4 Physical Specifications MaterialDiaphragm: stainless steel 316L, Hastelloy C,titanium alloyProcess connection: stainless steel 316L
Filling liquid: silicone oil, vegetable oil,food grade filling liquidTransmitter housing:aluminum alloy, epoxycoated on the outside; stainlesssteel housing optional.Nameplate: Stainless steel 304
WeightAbout 10 to 16.5 kg
Housing Protect LevelIP67
Electromagnetic compatibility schedule
No. Test Items Basic Standard Test ConditionsFunction
Level
1 Radiation interference (housing)GB/T 9254-2008
sheet530MHz~1000MHz Qualified
2Conducted interference
(DC power port)
GB/T 9254-2008
sheet10.15MHz~30MHz Qualified
3Electrostatic discharge (ESD)
immunityGB/T 17626.2-2006
4kV(Contact)
8kV(Air)B
4Radio frequency electromagnetic
field immunityGB/T 17626.3-2006 10V/m (80MHz~1GHz) A
5Power frequency magnetic field
immunityGB/T 17626.8-2006 30A/m A
6Electrical fast transient burst
immunityGB/T 17626.4-2008 2kV(5/50ns,5kHz) B
7 Surge immunity GB/T 17626.5-2008
500V(Between lines)
1kV ( Between line and
Ground)(1.2us/50us)
B
8Radio frequency field induced
conducted interference immunityGB/T 17626.6-2008 3V(150KHz~80MHz) A
Note: (1) A performance level description: During the test, the performance is normal within the limits of the technical
specifications.
(2) B performance level description: During the test, the function or performance is temporarily reduced or lost,
but it can be recovered by itself, and the actual operating conditions, storage and data are not changed.
RP1002-CS Sanitary Gauge/Absolute Pressure Transmitter General Specifications Specifications Samples
www.rocksensor.com 11 Shanghai Rocksensor Automation Co.,Ltd.
External Dimensions unit(mm)
a:Install Method and External Dimensions of the transmitter with capillary
Wall Installation Method Vertical piping installation method
Horizontal piping installation method(side) Horizontal piping connection (front)
RP1002-CS Sanitary Gauge/Absolute Pressure Transmitter General Specifications Specifications Samples
www.rocksensor.com 12 Shanghai Rocksensor Automation Co.,Ltd.
b: Dimensions of Direct Mount Transmitter
5 Electrical Connection
Note: The shortcut interface function is equivalent to the signal terminal.
RP1002-CS Sanitary Gauge/Absolute Pressure Transmitter General Specifications Specifications Samples
www.rocksensor.com 13 Shanghai Rocksensor Automation Co.,Ltd.
6 Model and Specification code TableGauge Pressure Transmitter Selection RP1002-
10 AccuracyCS Basic Accuracy ±0.1%
20 Span
B 0-3kPa~6kPa /(0-300~600 mmH2O)
C 0-4kPa~40kPa /(0-400~4000 mmH2O)
D 0-10kPa~250kPa /(0-1~25 mH2O)
F 0-100kPa~3MPa /(0-10~300 mH2O)
30 Diaphragm Material
S Stainless Steel 316L
C Hastelloy C
R Titanium alloy
40 Filling Fluid
A Silicon Oil
B Vegetable Oil
C Food grade filling Fluid
50 Process connection standard
A ASME BPE(default)
B ISO 2852
C DIN 32676
60 Process connection size
1 Tri-clamp 1” / DN 25(Capillary length select 0)
2 Tri-clamp 1.5” / DN 40
3 Tri-clamp 2” / DN 50
4 Tri-clamp 2.5” / DN 65
5 Tri-clamp 3” / DN 80
70 Capillary length
0 None
1 1m
2 2m
3 3m
4 4m
5 5m
6 6m
S Special Length
80 Mounting Bracket[1]
N None
1 Stainless Steel
2 Galvanized carbon steel
90 Display Selection
N None
2 LCD Backlit Display(-20℃)
3 OLED Display(-40℃)
100 Explosion Proof Selection
N Basic Type
RP1002-CS Sanitary Gauge/Absolute Pressure Transmitter General Specifications Specifications Samples
www.rocksensor.com 14 Shanghai Rocksensor Automation Co.,Ltd.
A Intrinsically safe,NEPSI
D Explosion Proof,NEPSI
B Intrinsically safe,ATEX
E Explosion Proof,ATEX
110 Tag Name Plate
N None
1 The number is marked on the nameplate
2 Hanging stainless steel signage
120 Document Requirement
N None
1 Test Report
2 Test Report + Cerification Report
130 Additional Options[2]
S Stainless Steel Housing
Note 1: If the direct mounting type does not require the installation bracket, then item 80 is selected as N.
Note 2: The line dead leg LDL (Line Dead Leg), customers need to be equipped with a dedicated DN25/40/50 three-way
interface, see LDL three-way interface information.
Option Example:Example:RP1002-CSCSAA3212NN2
[CS]Basic Accuracy:±0.1%
[C]Range:为 0~40kPa
[S]Wetted part: stainless steel 316L diaphragm
[A]Filling Fluid: Silicone Oil
[A] Process Connection Standard: ASME BPE
[3]Process connection size:Tri-clamp 2”
[2]Capillary length:2m
[1]Mounting bracket: stainless steel
[2]Display options: LCD backlit LCD display
[N]Explosion-proof: None
[N]tag: no
[2]Document Requirements: Test Report + Material Report
RP1002/3-DSH Sanitary Gauge/Absolute Pressure Transmitter General Specifications Specifications Samples
www.rocksensor.com 15 Shanghai Rocksensor Automation Co.,Ltd.
RP1002-DSH Sanitary Gauge
Pressure Transmitter
RP1003-DSH Sanitary
Absolute Pressure
Transmitter
The RP1002/3-DSH Sanitary Gauge /AbsolutePressure Transmitter is used to measure thepressure of a liquid or gas under hightemperature conditions and then convert it intoa 4 to 20 mADC current signal output with amaximum operating temperature of 200 ℃
Standard Specifications(Adjusting the range based on the standardzero point, stainless steel 316L diaphragm,filling fluid is silicone oil)
1 Performance SpecificationsReference Accuracy of Span Adjusting±0.25%(including nonlinearity,hysteresis and repeatability)
Ambient Temperature InfluenceTemperature Compensate Range: -10~65℃Zero<0.025%/℃Span<0.025%/℃
Overrange Influence±0.15%×Span
Stability±0.5%×Span /3 years
Power Supply Influence±0.005% /10V(12~42V DC)
2 Function SpecificationsSpan and RangeSpan
Code
Measure Range
(bar)
Span
Code
Measure Range
(bar)
C1 0 - 0.25 gauge F8 -1 - 3 gauge
C2 0 - 0.4 gauge F9 -1 - 5 gauge
C3 0 - 0.6 gauge FA -1 - 9 gauge
D1 0 - 1 gauge FB -1 - 15 gauge
D2 0 - 1.6 gauge FC -1 - 24 gauge
D3 0 - 2.5 gauge FD -1 – 29 gauge
F1 0 - 4 gauge
F2 0 - 6 gauge M1 0 - 1.0 Absolute
F3 0 - 10 gauge M2 0 - 1.6 Absolute
F4 0 - 16 gauge M3 0 - 2.5 Absolute
F5 0 - 25 gauge O1 0 – 4.0 Absolute
F6 0 - 30 gauge O2 0 – 6.0 Absolute
C5 -1 - 0 gauge O3 0 - 10 Absolute
D4 -1 - 0.6 gauge O4 0 - 16 Absolute
D5 -1 - 1.6 gauge O5 0 - 25 Absolute
Installation location influenceThe change in the mounting position parallel tothe diaphragm surface does not cause zero drift.If the mounting position and the diaphragmsurface exceed 90°, there is a zero influence inthe range of <0.15 kPa, and the range has noeffect.
Output2-wire type, 4 to 20mADC.Output signal limit: Imin=3.8mA, Imax=22mA
RP1002/3-DSH Sanitary Gauge/Absolute Pressure Transmitter General Specifications Specifications Samples
www.rocksensor.com 16 Shanghai Rocksensor Automation Co.,Ltd.
Response time< 0.2s
Preheat Time< 15s
Ambient Temperature-20~65℃
Storage temperature / Transport temperature-20~65℃
Medium Temperature-30~200℃
Pressure LimitFrom vacuum to maximum range.
Overload LimitSpan Code(First Letter)
Overload
PressureBurst Pressure
C 1MPa 2MPa
D、M 2MPa 4MPa
F、O 7.5MPa 15MPa
3 InstallationPower and load conditionsPower supply voltage: 24V,R ≤ (Us-12V) / ImaxkΩ, Where Imax=23 mAMaximum supply voltage: 36VDC
Minimum supply voltage: 10VDC
Electrical connectionsHirschmann connector, or M12 aviation socket,terminal block for 0.5 ~ 2.5mm2 wire.
Process interface standardASME BPE (default)ISO 2852DIN 32676
Process interface sizeTri-clamp DN25~DN80
4 Physical SpecificationsMaterialDiaphragm:stainless steel 316L,Hastelloy C, titanium alloyProcess connection: stainless steel 316LFilling liquid:silicone oil,vegetable oil,food gradefilling liquidTransmitter housing: stainless steel 304
Weight: 0.2~0.3kg
Housing Protect Level:IP65
External Dimension unit(mm)
See Below Drawing:
No Display Type Bevel display type Side square display type
RP1002/3-DSH Sanitary Gauge/Absolute Pressure Transmitter General Specifications Specifications Samples
www.rocksensor.com 17 Shanghai Rocksensor Automation Co.,Ltd.
5 Model and Specification SelectionSanitary Gauge Pressure Transmitter RP1002-Sanitary Absolute Pressure Transmitter RP1003-10 Accuracy
DSH Basic Accuracy ±0.25%,With heat sink
20 Span[1]
Gauge Pressure Transmitter RP1002-SD
C1 0- 0.25 bar
C2 0 - 0.4 bar
C3 0 - 0.6 bar
D1 0 - 1 bar
D2 0 - 1.6 bar
D3 0 - 2.5 bar
F1 0 - 4 bar
F2 0 - 6 bar
F3 0 - 10 bar
F4 0 - 16 bar
F5 0 - 25 bar
F6 0 - 30 bar
C5 -1 - 0 bar
D4 -1 – 0.6 bar
D5 -1 – 1.6 bar
F8 -1 - 3 bar
F9 -1 - 5 bar
FA -1 - 9 bar
FB -1 - 15 bar
FC -1 - 24 bar
FD -1 - 29 bar
SG Special Gauge Pressure Span
Absolute Pressure Transmitter RP1003-SD
M1 0 – 1.0 bar
M2 0 – 1.6 bar
M3 0 – 2.5 bar
O1 0 - 4 bar
O2 0 - 6 bar
O3 0 - 10 bar
O4 0 - 16 bar
O5 0 - 25 bar
SA Special Gauge Pressure Span
30 Diaphragm Material
S Stainless Steel 316L
C Hastelloy C
R Titanium alloy
40 Filling Fluid
A Silicon Oil
B Vegetable Oil
RP1002/3-DSH Sanitary Gauge/Absolute Pressure Transmitter General Specifications Specifications Samples
www.rocksensor.com 18 Shanghai Rocksensor Automation Co.,Ltd.
C Food Grage Filling Fluid
50 Process Connection Standard
A ASME BPE(Default)
B ISO 2852
C DIN 32676
60 Process Connection Size
1 Tri-clamp 1” / DN 25
Tri-clamp 1.5” / DN 40
Tri-clamp 2” / DN 50
Tri-clamp 2.5” / DN 65
Tri-clamp 3” / DN 80
2
3
4
5
50 Additional options[2](-)
1 Test Report
2 Material Report
A Top bevel display
B Side square display
Note 1: RP1002 corresponds to the selected gauge pressure range code, and RP1003 corresponds to the absolute
pressure range code;
Note 2: Additional options can be selected or multiple choices.
Option example:Example: RP1002-DSHC1SAA2-12[DSH] Basic error: ±0.25% with heat sink
[C1] Range: 0-0.25bar
[S] diaphragm material: 316L
[A] Filling Fluid: Silicone Oil
[A] Process Connection Standard: ASME BPE
[2] Process connection size: Tri-clamp 1.5”
[-12]: Test report + material report
RT2001-Thermal Resistance Temperature Transmitter General Specifications Specification Samples
www.rocksensor.com 19 Shanghai Rocksensor Automation Co.,Ltd.
RT2001-Thermal Resistance
Temperature Transmitter
The RT2001 Thermal Resistance TemperatureTransmitter measures the temperature of liquids,gases or vapors in the food and pharmaceuticalindustries and converts them into a 4 to 20mADC current signal output.
1 Technical DataMaximum temperature range-50~﹢200℃
Reference accuracy±0.2℃
Thermal resistor ferrulePt100 temperature sensor,DIN 60751, class A
Ambient Temperature-20~﹢55℃
Allowed medium temperature upper limit﹢200℃
Electrical ConnectionsCorrosion resistant aviation socket
Process Interface StandardASME BPE (default)ISO 2852DIN 32676
Process interface SizeTri-clamp DN15~DN100
Wet surface materialStainless steel 316LTitanium alloy
Protection Sleeve6mm outer diameter, length 30 ~ 150mm.
Responding time: <1s
Output4~20mADC, optional superimposed HARTprotocol
Power SupplyThe power supply voltage is 7.5-45VThe maximum load is max.:(V power -7.5V) / 0.022AElectrical isolation is U=2000VACCircuit limit is <22mAThe saturation current is 3.8mA at the low endand 20.5mA at the high end.
Housing Protect Level: IP67
External Dimension
RT2001-Thermal Resistance Temperature Transmitter General Specifications Specification Samples
www.rocksensor.com 20 Shanghai Rocksensor Automation Co.,Ltd.
2 Model and Specification SelecationThermal Resistance Temperature Transmitter RT2001-10 Basic Option[1]
S Stainless steel housing, output 4~20mADC
T Stainless steel housing, output 4~20mADC, Hart protocol communication
20 Probe length
1 50mm
2 100mm
3 150mm
4 30mm
30 Wet surface material
S 316L
R Titanium alloy
40 Process Connection Standard
A ASME BPE(Default)
B ISO 2852
C DIN 32676
50 Process Connection Size
0 Tri-clamp 0.5” / DN 15
1 Tri-clamp 1” Type B / DN 25
2 Tri-clamp 1.5” / DN 40
3 Tri-clamp 2” / DN 50
4 Tri-clamp 2.5” / DN 65
5 Tri-clamp 3” / DN 80
6 Tri-clamp 4” / DN 100
60 Additional Options[2](-)
1 Test Report
2 Material Report
Note 1: The temperature measurement range is set to -10-150 °C by default, and other measurement range settings are
required on the order;
Note 2: Additional options can be selected or multiple choices.
Option example:Example: RT2001-S1SA2-12[S] Basic option: stainless steel housing, output 4~20mADC
[1] Probe length: 50mm
[S] Water level material: 316L
[A] Process Connection Standard: ASME BPE
[2] Process connection size: Tri-clamp 1.5”
[-12]: Test report + material report
RT2003-Thermal resistance temperature transmitter General Specifications Specifications Samples
www.rocksensor.com 21 Shanghai Rocksensor Automation Co.,Ltd.
RT2003-Thermal resistance
Temperature Transmitter
The RT2003-Thermal Resistance Temper-ature Transmitter measures the temperatureof liquids, gases or vapors in the food andpharmaceutical industries and converts theminto a 4 to 20 mADC current signal output.
1 Technical DataWorking Temperature Range-10~﹢150℃
Reference Accuracy±0.5℃
Thermal Resistor Ferrule:Pt100 temperature sensor, EN60751, Class A
Ambient Temperature:-20~﹢55℃
Allowed Medium Temperature Upper Limit﹢150℃
Electrical ConnectionsCorrosion resistant aviation socket
Process Interface StandardASME BPE(Default)ISO 2852,DIN32676
Process Interface Size:Tri-clamp DN15~DN100
Wet Surface Material:Stainless steel 316LTitanium alloy
Protection Sleeves6mm outer diameter, length 30 ~ 150mm
Responding Time:<1s
OutPut:4~20mADC
Power SupplyThe power supply voltage is 7.5-45VThe maximum load is max.(V power -7.5V) / 0.022A,Electrical isolation is U=2000VACCircuit limit is <22mAThe saturation current is 3.8mA at the lowend and 20.5Ma at the high end.
Housing Protect Level:IP67
External Dimension
RT2003-Thermal resistance temperature transmitter General Specifications Specifications Samples
www.rocksensor.com 22 Shanghai Rocksensor Automation Co.,Ltd.
2 Model and Specification code TableTemperature Transmitter Selection RT2003-
10 Basic Options[1]
G All stainless steel design,output 4~20mADC
20 Probe Length
1 50mm
2 100mm
3 150mm
4 30mm
30 Wet surface material
S 316L
R Titanium alloy
40 Process Connection Standard
A ASME BPE(Default)
B ISO 2852
C DIN32676
50 Process Connection Size
0 Tri-clamp 0.5” / DN 15
1 Tri-clamp 1” Type B / DN 25
2 Tri-clamp 1.5” / DN 40
3 Tri-clamp 2” / DN 50
4 Tri-clamp 2.5” / DN 65
5 Tri-clamp 3” / DN 80
6 Tri-clamp 4” / DN 100
60 Additional options[2](-)
1 Test Report
2 Material report
Note 1: The temperature measurement range is set to -10-150℃ by default, and other measurement range settings are
required on the order;
Note 2: Additional options can be selected or multiple choices.
Selection example:Example: RT2003-G1SA2-12[G] Basic option: All stainless steel design, output 4~20mADC
[1] Probe length: 50mm
[S] Water level material: 316L
[A] Process Connection Standard: ASME BPE
[2] Process connection size: Tri-clamp 1.5”
[-12]: Test report + material report
RT2004-Thermal resistance Temperature Transmitter General Specifications Specifications Samples
www.rocksensor.com 23 Shanghai Rocksensor Automation Co.,Ltd.
RT2004-Thermal resistance
Temperature Transmitter
The RT2004 RTD temperature transmittermeasures the temperature of liquids, gasesor vapors in the food and pharmaceuticalindustries and converts them into a 4 to 20mADC current signal output.
1 Technical DataWorking Temperature Range-50~﹢200℃
Reference Accuracy±0.2℃
Thermal Resistor Ferrule:Pt100 temperature sensor, EN60751, Class A
Ambient Temperature:-20~﹢55℃
Allowed Medium Temperature Upper Limit﹢200℃
Electrical ConnectionsCorrosion resistant aviation socket
Process Interface StandardASME BPE(Default)ISO 2852,DIN32676
Process Interface SizeTri-clamp DN15~DN100
Wet Surface MaterialStainless steel 316LTitanium alloy
Protection Sleeves6mm outer diameter, length 30 ~ 150mm
Responding Time:<1s
OutPut:4~20mADC HART protocolCan be choose to Superimposed
Display:15° bevel LCD display
Power SupplyThe power supply voltage is 7.5-45VThe maximum load is max. (V power -7.5V) /0.022AElectrical isolation is U=2000VACCircuit limit is <22mAThe saturation current is 3.8mA at the lowend and 20.5mA at the high end.
Housing Protect Level: IP65
External Dimensions
RT2004-Thermal resistance Temperature Transmitter General Specifications Specifications Samples
www.rocksensor.com 24 Shanghai Rocksensor Automation Co.,Ltd.
2 Model and Specification code TableTemperature Transmitter Selection RT2004-
10 Basic Options[1]
K Stainless steel housing, 15°tilt LCD display, output 4 to 20mADC
L Stainless steel housing, 15°housing, 15°tilt LCD display, output 4 to 20mADC HART protocol
20 Probe Length
1 50mm
2 100mm
3 150mm
4 30mm
30 Wet Surface Material
S 316L
R Titanium alloy
40 Process Connection Standard
A ASME BPE(Default)
B ISO 2852
C DIN 32676
50 Process Connection Size
0 Tri-clamp 0.5” / DN 15
1 Tri-clamp 1” Type B / DN 25
2 Tri-clamp 1.5” / DN 40
3 Tri-clamp 2” / DN 50
4 Tri-clamp 2.5” / DN 65
5 Tri-clamp 3” / DN 80
6 Tri-clamp 4” / DN 100
60 Additional options[2](-)
1 Test Report
2 Material report
Note 1: The temperature measurement range is set to -10-150℃ by default, and other measurement range settings are
required on the order;
Note 2: Additional options can be selected or multiple choices.
Option example:Example: RT2004-K1SA2-12[K] Basic options: stainless steel housing, 15° tilt LCD display, output 4 to 20mADC
[1] Probe length: 50mm
[S] Water level material: 316L
[A] Process Connection Standard: ASME BPE
[2] Process connection size: Tri-clamp 1.5”
[-12]: Test report + material report
RF3000-DP Differential Pressure Flow Transmitter General Specifications Specifications Samples
www.rocksensor.com 25 Shanghai Rocksensor Automation Co.,Ltd.
RF3000-DP Differential
Pressure Flow Transmitter
The RF3000-Differential Pressure Flowmetermeasures the flow of pipe fluids in thepharmaceutical or food industry and convertsthem into 4-20mADC current signal outputs,HART digital communications.
Working PrincipleWhen the fluid flows through the throttlingdevice (differential pressure sensor) of theRF3000-differential pressure flowmeter,there isa pressure difference between the front sideand back side of the throttling device (P1-P2) isgenerated,and the pressure difference has acertain functional relationship with the flow rate.The electronic adapter collects the differentialpressure signal and converts it into a4-20mADC signal output after operation andamplification to achieve fluid flow measurement.
In addition to the instantaneous flow andcumulative flow output, the differential pressuresensor also integrates a pressure sensor and atemperature sensor, so that the pipe pressureand liquid temperature signals can also bedisplayed.The throttling device of the RF3000-Differen
-tial Pressure Flowmeter is designed withno dead angle and is made of 316L stainlesssteel and polished.
Standard Specification(Adjust the measuring range based on thestandard zero point, stainless steel 316Ldiaphragm, filling fluid is silicone oil)
1 Performance SpecificationReference accuracyFlow Measurement: ±0.5%、±1%
StabilityReference accuracy × Span /3 years
Power Supply Influence±0.001% /10V (12~362V DC),it can be negligible
2 Function SpecificationsFlow Measurement Range1: 0-1t/h2: 0-2t/h3: 0-3t/h5: 0-5t/h7: 0-7t/hA: 0-10t/hB: 0-15t/hC: 0-20t/hD: 0-30t/h
RF3000-DP Differential Pressure Flow Transmitter General Specifications Specifications Samples
www.rocksensor.com 26 Shanghai Rocksensor Automation Co.,Ltd.
Installation Location InfluenceVertical installation is recommended. Thechange of the installation position parallel to thediaphragm surface will not cause zero drift. Ifthe installation position and the diaphragmsurface exceed 90°, the zero position in therange of <0.4 kPa will occur, and the flow willalso be affected. The zero output can becorrected by adjusting the zero adjustment. Norange effect.
Output4~20mADC output,HART digital communication.Output signal limit: Imin=3.9mA, Imax=20.5mA
Alarm CurrentUnderreport mode (minimum): 3.7mAOvertray mode (maximum): 21 mANo report mode (hold): Maintain the effectivecurrent value before the faultAlarm current standard setting: high-reportmode
Response TimeThe amplifier component has a dampingconstant of 0.1 s; the sensor time constant is0.1 to 1.6 s, depending on the range andturndown ratio. The additional adjustable timeconstant is: 0.1 to 60 s.
Preheat Time< 15s
Ambient Temperature0 to 65 °C
Storage Temperature /Transport Temperature-40 to 85°C
Medium Temperature Limit150℃
Working Pressure LimitFrom 3.5 kPa absolute pressureto rated pressure.
Electromagnetic Compatibility (EMC)See "Electromagnetic Compatibility Schedule"on the next page.
3. InstallationPower and Load ConditionsThe power supply voltage is 24VR ≤ (Us-12V) / Imax kΩWhere Imax=23 mAMaximum supply voltage: 36VDCMinimum supply voltage: 15VDCDigital communication load range: 230 ~ 600Ω
Electrical ConnectionsM16X1.5 waterproof air socket, terminal blockfor 0.5 ~ 2.5mm2 wire.
Process Interface StandardsASME BPE(Default)ISO 2852DIN 32676
Process Interface SizeTri-clamp DN25~DN80
4 Physical SpecificationsMaterialMeasuring bellows: stainless steel 316LDiaphragm: stainless steel 316LProcess connection: stainless steel 316LFilling liquid: silicone oilTransmitter housing: 316L pipe,304 stainless steel cover
Weight3kg~5kg
Housing Protection LevelIP67
RF3000-DP Differential Pressure Flow Transmitter General Specifications Specifications Samples
www.rocksensor.com 27 Shanghai Rocksensor Automation Co.,Ltd.
Electromagnetic Compatibility Schedule
No. Test items Basic standard Test ConditionsPerform
-ance Level
1 Radiation interference (housing)GB/T 9254-2008
sheet 530MHz~1000MHz qualified
2Conducted interference
(DC power port)
GB/T 9254-2008
sheet 10.15MHz~30MHz qualified
3Electrostatic discharge (ESD)
immunityGB/T 17626.2-2006
4kV(Contact)
8kV(Ai)B
4Radio frequency electromagnetic
field immunityGB/T 17626.3-2006 10V/m (80MHz~1GHz) A
5Power frequency magnetic field
immunityGB/T 17626.8-2006 30A/m A
6Electrical fast transient burst
immunityGB/T 17626.4-2008 2kV(5/50ns,5kHz) B
Note:
(1) A performance level description: During the test, the performance is normal within the limits of the technical
specifications.
(2) B performance level description: During the test, the function or performance is temporarily reduced or lost, but it
can be recovered by itself, and the actual operating conditions, storage and data are not changed.
5 External Dimension(Example: DN40)
RF3000-DP Differential Pressure Flow Transmitter General Specifications Specifications Samples
www.rocksensor.com 28 Shanghai Rocksensor Automation Co.,Ltd.
6 Model and Specification Code TableDP type differential pressure flow transmitter selection RF3000-10 Accuracy
E ±0.5%
F ±1%
20 Span
1 0-0.1~1t/h A 0-1~10t/h
2 0-0.2~2t/h B 0-1.5~15t/h
3 0-0.3~3t/h C 0-2~20t/h
5 0-0.5~5t/h D 0-3~30t/h
7 0-0.7~7t/h
30 Process interface standard
A ASME BPE(Default)
B ISO 2852
C DIN 32676
40 Process interface size 参考流量(t/h)
1 Tri-clamp 1” Type B / DN 25 1、2、3、5
2 Tri-clamp 1.5” / DN 40 3、5、7、10
3 Tri-clamp 2” / DN 50 5、7、10、15
4 Tri-clamp 2.5” / DN 65 7、10、15、20
5 Tri-clamp 3” / DN 80 10、15、20、30
50 Additional options[1](-)
1 Test Report
2 Material Report
Note 1: Additional options can be selected or multiple choices
Option example: Example: RF3000-F511A2-12[F]: Accuracy ±1%
[5]: The flow measurement range is 0-5t/h [1]: with the test report;
[A]: Process Interface Standard ASME BPE
[2]: Process interface size Tri-clamp 1.5”
[-12]: Test report + material report
RF3100- Coriolis Mass Flowmeter General Specifications Specifications Samples
www.rocksensor.com 29 Shanghai Rocksensor Automation Co.,Ltd.
RF3100- Coriolis Mass
Flowmeter
The RF3100-Coriolis mass flow meter is a flowmeter for metering the flow of fluid through across-section, showing fluid quality directly andmore intuitively. It can measure parameterssuch as mass flow, density and temperatureonline, widely used in pharmaceutical, food andother fields to realize functions such as tradesettlement and industrial process control. TheRF3100 ensures accurate response, optimizeproduction, enhance safety and save onmaintenance costs.
Working PrincipleAs shown in the figure below, the Coriolis massflowmeter is a direct mass flow meter made bythe Coriolis force principle that is in a rotatingsystem while the fluid moves in a straight line,which is proportional to the mass flow.
Standard Specification1 Performance specificationsAccuracy: 0.15, 0.2, 0.5 (default)
StabilityGood reliability and long service life (no flowblocking and moving parts in the fluid channel).
Verification PeriodGenerally, it is no more than one year than
grade 0.5, and no more than two years of grade0.5 and below.
Power supply impact15VDC~40VDC
2 Functional SpecificationsRange Ratio: 20:1Installation location influence
Warning
When installing horizontally orvertically, the flow direction of thepipeline must be the same as theindicator arrow on the flowmeter body. If the flowmeter requires verticalinstallation, the flow must be from bottomto top.
Horizontal installation Diagram:
Vertical installation Diagram
RF3100- Coriolis Mass Flowmeter General Specifications Specifications Samples
www.rocksensor.com 30 Shanghai Rocksensor Automation Co.,Ltd.
OutputModbus/RS-485, pulse, 4-20mA current loop /HART
Power-on warm-up time20min
Ambient temperature-40°C~+55°C
Working pressure≤ 4MPa
Electromagnetic compatibility (EMC)See "Electromagnetic Compatibility Schedule"
3 InstallationPower supply and load partsVoltage input range 15VDC ~ 40VDC
Electrical connectionsWiring the transmitter should tighten theelectrical connection plug to prevent flammablegases, moisture and dust from entering. The
transmitter's wiring compartment has twoseparate electrical connection wires (M20×1.5)for power and output signal wiring.
Process interface standardASME BPEISO 2852
Process interface sizeTri-clamp DN15~DN50
4 Physical specificationsMaterialSensor body: 304Sensor measuring tube: 316L
Housing Protect LevelIP67
Electromagnetic compatibility schedule
No. Test Item Basic Standard Test Condition
1 Electrostatic discharge immunityGB/T17626.2,Class 3,
A kind
Flowmeter for AC and DC power
supply
2 Electrical fast transient burst immunity GB/T17626.4,Class 3 Flowmeter for AC power supply
3 Surge (impact) immunity GB/T17626.5,Class 2 Flowmeter for AC power supply
4Voltage dips, short interruptions, and
voltage changesGB/T17626.11 Flowmeter for AC power supply
Note: During the electromagnetic compatibility test, the flowmeter should work normally, there should be no procedural
disorder and dysfunction, and the memory data should not be lost or changed.
RF3100- Coriolis Mass Flowmeter General Specifications Specifications Samples
www.rocksensor.com 31 Shanghai Rocksensor Automation Co.,Ltd.
5 External Dimensions(Example: DN15)
RF3100- Coriolis Mass Flowmeter General Specifications Specifications Samples
www.rocksensor.com 32 Shanghai Rocksensor Automation Co.,Ltd.
6 Model and Specification SelectionRF3100-Mass Flowmeter Selection
10 Accuracy
A Class 0.5(Default)
B Class 0.2
C Class 0.15
20 Display On site
1 None
2 LED Backlit LCD Display(-20℃)
3 OLED Display(-40℃)
30 Voltage Supply
A 12v-24vDC
B 110V-240VAC
40 Communication Protocol
1 HART
2 Modbus-485
50 Output Signal
A 4-20 mA
B RS-485
C Pulse
60 Process Connection Standard
1 ASME BPE(默认)
2 ISO2852
3 DIN32676
70 Process Connection Size Reference Flow
A Tri-clamp 0.5” / DN15 30~3000 kg/h
B Tri-clamp 1” Type B / DN25 80~8000 kg/h
C Tri-clamp 1.5” / DN40 320~32000 kg/h
D Tri-clamp 2” / DN50 500~50000 kg/h
E Others
80 Wetted pipe material
1 Stainless Steel 316L(Default)
2 Hastelloy C
3 Others
90 Explosion-proof / special options
A Basic Type
B Explosion Proof
C Intrinsically Safe
D Thunder Proof
100 Tag sign
1 None
2 Located on the nameplate
3 Hanging stainless steel signs
110 Manual
A Chinese
B English
RF3100- Coriolis Mass Flowmeter General Specifications Specifications Samples
www.rocksensor.com 33 Shanghai Rocksensor Automation Co.,Ltd.
120 Additional options【-】
1 Test Report
2 Material Report
Note: Additional items can be unselected or multiple choices.
Option example: Example: RF3100—A2A1A1D1A1A-12
[A]: Accuracy ±0.5%
[2]: LED backlight LCD display
[A]: Power supply voltage: 24V
[1]: HART Communication
[A]: Output signal: 4~20 mA
[1]: Interface connection standard: BPE
[D]: Interface size: Tri-clamp 2"
[1]: Liquid pipe material: 316L
[A]: Explosion type: none
[1]: Bit number: None
[A]: Chinese manual
[-12]: Test report + material report
Appendix: Process Connection General Specifications Specifications Samples
www.rocksensor.com 34 Shanghai Rocksensor Automation Co.,Ltd.
Appendix: Process Connection
1. Process connection (chuck type, standard)
ASME BPE
Nominal
diameter
DIN 32676
Nominal
diameter
ISO 2852
Nominal
diameter
ASME BPE DIN 32676 ISO 2852
K D K D K D
1/2” 15 12.7 20.3 25 27.5 34 27.5 34
1” 25 25 43.5 50.4 43.5 50.5 43.5 50.5
1 1/2” 40 38 43.5 50.4 43.5 50.5 43.5 50.5
2” 50 51 56.5 64 56.5 64 56.5 64
2 1/2” 65 63.5 70.6 77.4 83.5 91 70.6 77.4
3” 80 76.1 83.5 91 97 106 83.5 91
4” 100 101.6 110 119 110 119 110 119
2. Process connection (customizable type)
Coupling type (DIN 11851)
Nominal
diameter
D RD
25 44 RD52x1/6
32 50 RD58x1/6