aquametrix · 2018. 9. 4. · water analytics aquametrix solutions for the most challenging...

12
by Water Analytics Aqua Metrix Solutions for the Most Challenging Environments Short Catalog Feb, 2018

Upload: others

Post on 26-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • byWater Analytics

    AquaMetrixSolutions for the Most Challenging Environments

    Short Catalog

    Feb, 2018

  • makers of AquaMetrix instruments

    AquaMetrixAM-2300 Multi-Input, Multi-Parameter Controller

    • Inputsforfour4-20mAsensorsofanykindinanycombination: pH,ORP,conductivity,dissolvedO

    2,Chlorine,andmore

    • Inputsforthreefrequencyorpulsecounters,includingflowsensors

    • Outputsoffourrelaysprogrammableforanyoftheinputs

    • Expandnumberofinputs,outputsorrelayswithanexpansionslot

    • Notificationsbye-mail,text,and/ordisplayforeachinput

    • Datalogging—downloadablefromweb

    • 100%webenabledfromset-uptodatacollectiontoremote viewingwithpasswordprotection

    • 1/4DINpanelmountedenclosurewithadapterforwallmounting

    PartNumber Description

    AM-2300-0 4XAnalogand3XDigitalInputswith4XRelays

    AM-2300-1 8XAnalogand3XDigitalInputswith4XRelays

    AM-2300-2 4XAnalogand3XDigitalInputswith4XRelaysand4XAnalogOutputs

    AM-2300-3 4XAnalogand6XDigitalInputswith8XRelays

    AM-2300-4 4XAnalogand3XDigitalInputswith10xRelays

    AM-2300-5 8XAnalogInputsand6XRelays

    AM-2300-6 4XAnalogand7XDigitalInputswith6XRelays

    AM-2300-8 8XAnalogInputsand12XRelays

    Web Interface

    AM-2300

  • makers of AquaMetrix instruments

    AquaMetrix AM-2250 Multi-Parameter Controller • pH,ORP,conductivity&flowparametersavailable

    • Highlyvisiblelargeback-litLCDdisplay

    • Flexible and easy calibration, including multi-pointconductivitycalibrationforacidsandbases

    • Threecontrolrelaysforrisingorfallingprocesses

    • Two 4-20 mA outputs with range scaling andtemperature

    • PIDControl

    • Universal mounting hardware provided for surface,panelmounting.Optionalpipemounting

    • CompatiblewithAquaMetrix60-seriesdifferentialpH/ORP sensors, 500-series combination pH/ORP sensors,AS/AM-series conductivity cells, and most pulsed flowsensors

    • SamefootprintasAM-2250(Panelcutoutis5.4”x5.4”)

    • pH,ORP,conductivity&flowparametersavailable

    • CompatiblewithAquaMetrix60-seriesdifferentialpH/ORPsensors,500-seriescombinationpH/ORPsensors,AS/AM-seriesconductivitycells,andmostpulsedflowsensors

    • Universalmountinghardwareprovidedforsurface,panelmounting.OptionalpipeandDINrailmounting

    • 24VDC:looppoweredorexternallypowered

    • Norelays

    • LargeLCDdisplay

    • 4-20mAoutput

    • PIDcontrol

    PartNumber Description

    AM-2250 120/240VACPowerwithMountingKit.

    AM-2251 120/240VACPowerwithMountingKit

    AM-2250TX 24VDCPowerwithMountingKit

    2250-DIN-MNT DINRailMountingBracketfor2250TX

    2250-PIPE-MNT PipeMountigBracketforAM-2250/AM-2250TX

    AM-2250TX Multi-Parameter Transmitter

    AM-2250

    AM-2251 Multi-Parameter Controller NEW• pH,ORP,Toroidalconductivity&D.O.parameters available

    • Highlyvisiblelargeback-litLCDdisplay

    • Flexibleandeasycalibration,includingmulti-pointconductivitycalibrationforacidsandbases

    • Threecontrolrelaysforrisingorfallingprocesses

    • Two4-20mAoutputswithrangescalingandtemperature

    • PIDControl

    • Universalmountinghardwareprovidedforsurface,panelmounting.Optionalpipemounting

    • CompatiblewithAquaMetrix60-seriesdifferentialpH/ORPsensors,500-seriescombinationpH/ORPsensors,AM-ES1wide rangetoroidalsensor,AM-CDOclarkcelldissolvedoxygensensorandtheAM-P91dissolvedoxygensensor

  • makers of AquaMetrix instruments

    AquaMetrix

    • Differentialmeasurementtechnology

    • Immunetogroundloops

    • Replaceablesaltbridge

    • Replaceablereferencesolution

    • Lowcostofownership

    • Field-proven

    • Encapsulatedpreamplifier(60-series)

    • Ecapsulated4-20mAtwo-wireblindtransmitter(65-series)

    • Dual4-20mAoutput(pH+temperatureorORP+temperature)(PTandRTsensors)

    • Transmitsupto3000ft

    60 and 65 Series Differential pH or ORP Sensors

    PartNumber Description

    P60R8 1.5”MNPTFixedInsertionpHSensor

    R60R8 1.5”MNPTFixedInsertionORPSensor

    P60R5 1”MNPTFixedInsertionpHSensor

    R60R5 1”MNPTFixedInsertionORPSensor

    AM-CFT-R5 CompressionfittingtoconvertR5sensortovariableinsertion

    P60C7 Hot-TapInsertionpHSensor

    P65R8 1.5”MNPTFixedInsertionpHSensorwith4-20output

    P65R5 1”MNPTFixedInsertionpHSensorwith4-20output

    PT65R8 1.5”MNPTFixedInsertionpH+TemperatureSensorwithtwoisolated4-20outputs

    RT65R8 1.5”MNPTFixedInsertionORP+TemperatureSensorwithtwoisolated4-20outputs

    P60R8

    P60R5

    • Industrialgradecombinationprobesatlowcost

    • Doublejunctionelectrodeforlongerlife

    • Automatictemperaturecompensationisstandard

    • FixedInsertion(575-series)orvariableinsertion(585-series)

    • Universalstyle:flow-throughorsubmersion

    500 Series Combination pH or ORP Sensors

    PartNumber Description

    P575T1 1”MNPTFixedInsertionpHsensor

    P585T1 VariableInsertionpHsensorwith3/4”fitting

    R575T1 1”MNPTFixedInsertionORPsensor

    R585T1 VariableInsertionORPsensorwith3/4”fitting

    NEW

    P585T1

    R575T1

  • makers of AquaMetrix instruments

    AquaMetrix

    TheES5sensorsconnectstoAquaMetrix2300andPLC

    TheAM-ES1ConnectswiththeAM-2251Controller

    AS Series CPVC Conductivity Sensors

    AM Series 316 Stainless Steel Conductivity Sensors

    ES Series Toroidal Conductivity Sensors

    • 316SSorGraphiteElectrodes

    • AutomaticTemperatureCompensation

    • AdjustableInsertionLength

    • Widerangeofcellconstants

    PartNumber Description

    AM341K1 3/4”ODsensor,CellConststantk=1,Kynarfitting

    AM121S1 1/2”ODsensor,CellConststantk=1,316SSfitting

    AMB341S1 3/4”ODsensorforboilerapplications,CellConststantk=1,316SSfixedinsertion

    PartNumber Description

    AM-ES1 WideRangeToroidalSensor

    ES-5-C-1 ToroidalSensorw1.5”MNPT,0-10mS/cm

    ES-5-C-2 ToroidalSensorw1.5”MNPT,0-100mS/cm

    ES-5-C-3 ToroidalSensorw1.5”MNPT,0-1,000mS/cm

    PartNumber Description

    ASM001P1 Cellconstantk=0.01,316SSElectrode

    ASM01P1 Cellconstantk=0.1,316SSElectrode

    ASM1P1 Cellconstantk=1,316SSElectrode

    ASG10P1 Cellconstantk=10,GraphiteElectrode

    ASG50P1 Cellconstantk=50,GraphiteElectrode

    AM-ES1

    ES-5

    • 316SSelectrodes

    • Reducedcleaningrequirements

    • Widerangeofcellconstants

    • AutomaticTemperatureCompensation

    • Glandfittingallowsremovalandreplacementwithouttools

    • LowMaintenance-Reducedcleaningrequirements

    • Noelectrodecorrosion-Toroidisfullyencapsulated

    • Automatictemperaturecompensation

    ASG1P1

    ASM1P1

    AMB341S1

    NEW

  • makers of AquaMetrix instruments

    AquaMetrix

    PartNumber Description

    AM-ODO OpticalDOProbe

    AM-ODO-CAP ReplacementCap

    AM-CDO Clark Cell Dissolved OxygenConnectstoAquaMetrixAM-2251and2200D

    PartNumber Description

    AM-CDO-015 AmperometricDissolvedOxygenSensor

    • Polarographic(Clark)stylemeasurement

    • Widedynamicrange0-250%saturation

    • Transmissionupto2000ft.

    • ReplacesAM-P91Sensor

    PartNumber Description

    AM-FCL-05 FreeChlorineSensor,5ppm

    AM-FCL-FC SensorFlowCell

    AM-FCL-FM VariableAreaFlowMeter

    AM-FCL-RE ReplacementElectrolyte

    AM-FCL-MC ReplacementMembraneCap

    AM-FCL Chlorine Direct Output SensorConnectstoAquaMetrixAM-2300andPLC

    • 4-20mAoutput

    • Compactdesign

    • Automatictemperaturecompensation

    • Optionalflowcellandflowmeterinsures constantpressureforaccuratemeasurement

    • Inexpensivereplaceablemembraneandelectrolyte

    AM-ODO Optical Dissolved Oxygen Direct Output SensorConnectstoAquaMetrixAM-2300andPLC

    • Dualoutput:%saturationandconcentration(mg/l)

    • Directoutputvia4-20mA

    • Instantlystablevalues

    • Calibratedinthefactorywithcalibrationdatastoredinsensor

    • Only1replaceablepart-sensorcap.

    • Economicallypriced

    NEW

    AM-FCL

    AM-CDO

    AM-ODO

  • makers of AquaMetrix instruments

    AquaMetrix

    Whitelightsourcealsoavailable

    AM-LL Liquid Level Controller

    • ACbasedconductivity

    • SPDT(singlepoledoublethrow)relay

    • Builtinsensitivityadjustment(timerforLL3)

    • Currentandvoltagelimited

    • NEMA1enclosure

    AM-TBR Turbidity SensorConnectstoAquaMetrixAM-2300andPLC

    • Nephilometricmeasurement

    • Looppowereddirect4-20mAoutput(IRVERSION)

    • Optionalconstantpressureflowcell

    • Automatictemperaturecompensation

    PartNumber Description

    AM-TBR-IR4 Infraredlightsource4NTUrange

    AM-TBR-IR40 Infraredlightsource40NTUrange

    AM-TBR-IR400 Infraredlightsource400NTUrange

    AM-TBR-FC40 FlowCellfor4-40NTUsensor

    AM-TBR-FC400 FlowCellfor400NTUsensor

    PartNumber Description

    AM-LL-3 FreeChlorineSensor,5ppm

    AM-LL-4 SensorFlowCell

    AM-LL-7 VariableAreaFlowMeter

    AM-LL-7H ReplacementElectrolyte

    AM-LL7

    AM-TBR

  • makers of AquaMetrix instruments

    AquaMetrix

    Additionalmountingoptionsandsensormaterialsavailable

    Additionalmountingoptionsandsensormaterialsavailable

    IP810 Seametrics Paddle Wheel Flow SensorConnectstoAquaMetrixAM-2300andAM-2250

    • PulsedoutputworkswithAM-2250controller

    • Forpipediametersof3/8”to48”

    • IPsensorwithKynarimpeller,rubyjewel bearingandtungstencarbideshaft

    • PulsedoutputworkswithAM-2250controller

    • Forpipediametersof3/8”to48”

    • EXsensorwithnomovingpartsand superiorlow-flowperfomance

    EX810 Seametrics Magmeter Flow SensorConnectstoAquaMetrixAM-2300andAM-2250

    PartNumber Description

    IP80PTP-075 PolyurathanePaddleWheelwith3/4”Tee

    IP80PTP-100 PolyurathanePaddleWheelwith1”Tee

    IP80PTP-150 PolyurathanePaddleWheelwith1.5”Tee

    IP80PTP-200 PolyurathanePaddleWheelwith2”Tee

    PartNumber Description

    EX810PTP-075 Polyurathanemagmeterwith3/4”Tee

    EX810PTP-100 Polyurathanemagmeterwith1”Tee

    EX810PTP-150 Polyurathanemagmeterwith1.5”Tee

    EX810PTP-200 Polyurathanemagmeterwith2”Tee

    IP810

    EX810

  • makers of AquaMetrix instruments

    AquaMetrixSensor Applications

    Controller Compatability ChartSensor Part# AM-2250 AM-2250TX AM-2251 AM-2300

    60 Series Sensors √ √ √

    65 Series Sensors √

    500 Series Sensors √ √ √

    AS Series Sensors √ √

    AM Series Sensors √ √

    ES-5 Toroidal Sensors √

    AM-ES1 Toroidal Sensor √

    AM-ODO Sensors √

    AM-CDO Sensors √

    AM-FCL Sensors √

    AM-TBR √

    Seametrics Flow Sensors √ √ √

    Conductivity Cell Constant Chart

    Application pH ORP Conductivity D.O. Level Flow Chlorine

    Wastewater √ √ √ √ √

    Filtration √ √ √ √ √

    HVAC √ √ √

    Pump/Lift Station √ √

    Tank Monitoring √ √

    Aquaculture √ √ √ √ √

    Food & Beverage √ √ √ √ √

  • 100 School StreetAndover, MA 01810

    978-749-9949fax: 978-749-9961

    www.WaterAnalytics.net

    byWater Analytics