Ponding – The batten bars, cover strips, and seams produce raised areas that let water pool and often cause EPDM seam failures. These areas are easily repaired using Andek products which are not affected by ponding water. Andek products are UL and FM rated offering a light reflective Energy Star rating with a 10 yr renewable manufactures watertight warranty.

Seam Failure – EPDM seam failures occur as the material shrinks and lose elasticity. Seams are easily repaired using reinforced Andek Roof Fab material over the seams, while the black roof is turned white using UL and FM rated products with a light reflective Energy Star rating which can provide a 10 yr renewable manufactures watertight warranty.

Marshall Ryerson Company - Andek Territory Manager- Fluke Thermal Imaging Specialist www.andek.com 616-299-1751 - [email protected]

Page 3: 22 Year Old Epdm Restoration 2009 07

Image InfoAir Temperature 80.0°F Camera ModelTi55FT Manufacturer Fluke

EPDM Surface Temp 220.6 Degrees at the Roof Top AC Unit 5/20/2009 Time 12:18:33 PM

• Notes • Out of Warranty - Reaching useful service life.

Black EPDM Roof 80 Degree F Outside Air Temp 12:10 in the afternoon Existing smooth surface EPDM roof can be left in place and used as a canvass to accept the new Andek system.

• New waterproofing system will incorporate the thickness of the existing EPDM plus the thickness of the new Andek system and will qualify for a new 10 year manufacturer’s warranty which may be renewable. Thermal scan can show if the existing roof and insulation can be reused and saved while protecting precious landfill space.

• Thermal image shows extreme signs of daytime heating of the black EPDM membrane causing increased air conditioning demands. High roof surface temperatures contribute to urban heat island effects. Each fastener used to hold the insulation down act as heat syncs which transfers the heat to the inside of the building. It is not uncommon to have a fastener every 3 square feet in roofing assemblies.

Marshall Ryerson Company - Andek Territory Manager- Fluke Thermal Imaging Specialist www.andek.com 616-299-1751 - [email protected]

Page 4: 22 Year Old Epdm Restoration 2009 07

Scrim Reinforced Andek ROOFAB embedded in Andek POLAROOF RAC over all EPDM Field Seams. 50 square feet per gallon coverage (30 wet mils)

Sample of Andek ROOFAB embedded in Andek RAC

Existing smooth surface EPDM roof can be left in place and used as a canvass to accept the new Andek system. New waterproofing system will incorporate the thickness of the existing EPDM plus the thickness of the new Andek system and will qualify for a new 10 year manufacturer’s warranty which may be renewable.

The existing roof and insulation can be reused and saved while protecting precious landfill space.

Sustainable Roof – Seams beginning to separate

Out of Warranty - Reaching useful service lifeEPDM Roofing 22 Yrs Old

Black EPDM Temp204.5°F at base of AC unit

Marshall Ryerson Company - Andek Territory Manager- Fluke Thermal Imaging Specialist www.andek.com 616-299-1751 - [email protected]

May 20, 2009 80 Degree Air Temp

Page 5: 22 Year Old Epdm Restoration 2009 07

Scrim Reinforced Andek ROOFAB embedded in Andek POLAROOF RAC over all EPDM Field Seams. 50 square feet per gallon coverage (30 wet mils)

Sample of Andek ROOFAB embedded in Andek RAC

Existing smooth surface EPDM roof can be left in place and used as a canvass to accept the new Andek system. New waterproofing system will incorporate the thickness of the existing EPDM plus the thickness of the new Andek system and will qualify for a new 10 year manufacturer’s warranty which may be renewable.

The existing roof and insulation can be reused and saved while protecting precious landfill space.

Sustainable Roof – Seams beginning to separate

Out of Warranty - Reaching useful service lifeEPDM Roofing 22 Yrs Old

Andek Product SampleThermal Image Shot EPDM vs . Andek

Black EPDM Temp195.5°FMay 20, 2009 80 Degree Air Temp

Andek RAC Coating Temp over EPDM77.5°F

Marshall Ryerson Company - Andek Territory Manager- Fluke Thermal Imaging Specialist www.andek.com 616-299-1751 - [email protected]

Page 6: 22 Year Old Epdm Restoration 2009 07

Air Temperature 80.0°F Camera ModelTi55FT Manufacturer Fluke EPDM Seam Reinforced with Andek Surface Temp 84.2 Degrees Air Temp 80.0 Degrees

5/20/2009 Time 12:49:07 PM

• Proposal - Savings to the Owner $80,000

• Provide labor, materials, equipment and supervision necessary to complete the installation of the new Andek system utilizing the existing EPDM including: Reinforcing all field seams using the application of Andek ROOFAB & POLAROOF RAC.....Scrim Reinforced Andek ROOFAB embedded in Andek Polaroof RAC over all EPDM Field Seams. 50 square feet (30 wet mils)....... POLAROOF RAC - Applied 1 gallon per 100 square feet (15 wet mils) over entire roof after seams have been reinforced.......POLAROOF NW - Apply White Energy Star Rated, POLAROOF NW at the rate of 1 gallon per 100 square feet (15 wet mils).

• Overall system thickness reaches over 100 mils EPDM + Andek

• 10 or 15 yr renewable manufacturer warranty

Marshall Ryerson Company - Andek Territory Manager- Fluke Thermal Imaging Specialist www.andek.com 616-299-1751 - [email protected]

Page 7: 22 Year Old Epdm Restoration 2009 07

22 Year Old EPDM Andek Roof Restoration

• Andek Polaroof RAC and Roof Fab adds reinforcement and strength to EPDM seams without the need to strip EPDM seams in using costly EPDM materials. This repair procedure is warranted for 10 yrs

Marshall Ryerson Company - Andek Territory Manager- Fluke Thermal Imaging Specialist www.andek.com 616-299-1751 - [email protected]

Page 8: 22 Year Old Epdm Restoration 2009 07

• All field seams reinforced with Andek Roof Fab and encapsulated prior to first application of a urethane Polaroof RAC.

22 Year Old EPDM Andek Roof Restoration

Marshall Ryerson Company - Andek Territory Manager- Fluke Thermal Imaging Specialist www.andek.com 616-299-1751 - [email protected]

Page 9: 22 Year Old Epdm Restoration 2009 07

• Coverage of Andek urethane base coat is carefully monitored to assure proper coverage.

22 Year Old EPDM Andek Roof Restoration

Marshall Ryerson Company - Andek Territory Manager- Fluke Thermal Imaging Specialist www.andek.com 616-299-1751 - [email protected]

Page 10: 22 Year Old Epdm Restoration 2009 07

• New system incorporates existing EPDM thickness of .060 mils plus two coats of 15 wet mils Andek over the field of the roof plus additional .30 wet mil reinforced thickness at seams and penetrations. The new waterproof protection often exceeds 100 mils. Existing insulation and taper is salvaged and kept out of landfills. New 10 year renewable warranty.

22 Year Old EPDM Andek Roof Restoration

Marshall Ryerson Company - Andek Territory Manager- Fluke Thermal Imaging Specialist www.andek.com 616-299-1751 - [email protected]

Page 11: 22 Year Old Epdm Restoration 2009 07

• Completed EPDM Roof Restoration – All existing EPDM field seams are reinforced using Andek Polaroof RAC & Roof Fab. A base coat of Andek Urethane RAC is applied followed by a top coat of white Energy Star Rated Andek Polaroof NW.

• Completed installation gets a Renewable 10 Yr Warranty.

• Building Owner saved $80,000, stopped the leaks, and got a 10 year renewable warranty