ZXG10-BS30Compact Outdoor BTS
Maintenance Manual(Emergency Handling)
Version 1.5
ZTE CORPORATIONZTE Plaza, Keji Road South,
Hi-Tech Industrial Park,Nanshan District, Shenzhen,P. R. China518057Tel: (86) 755 26771900 800-9830-9830Fax: (86) 755 26772236
URL: http://support.zte.com.cnE-mail: [email protected]
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
2/37
LEGAL INFORMATION
Copyright 2006 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction ordistribution of this document or any portion of this document, in any form by any means, without the prior writtenconsent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected bycontractual confidentiality obligations.
All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTECORPORATION or of their respective owners.
This document is provided as is, and all express, implied, or statutory warranties, representations or conditionsare disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose,title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from theuse of or reliance on the information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applicationscovering the subject matter of this document. Except as expressly provided in any written license between ZTECORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.
The contents of this document and all policies of ZTE CORPORATION, including without limitation policies related tosupport or training are subject to change without notice.
Revision History
Date Revision No. Serial No. Purpose
10-Aug-06 R1.0 sjzl20061265 English For Customers
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
3/37
ZTE CORPORATIONValues Your Comments & Suggestions!
Your opinion is of great value and will help us improve the quality of our productdocumentation and offer better services to our customers.
Please fax to: (86) 755-26772236; or mail to Documentation R&D Department,ZTE CORPORATION, ZTE Plaza, A Wing, Keji Road South, Hi-Tech Industrial Park,Shenzhen, P. R. China 518057.
Thank you for your cooperation!
DocumentName
ZXG10-BS30 (V1.5) Compact Outdoor BTS Maintenance Manual (Emergency Handling)
Product Version V1.5Document RevisionNumber
R1.0
Equipment Installation Date
Presentation:
(Introductions, Procedures, Illustrations, Completeness, Level of Detail, Organization,Appearance)
Good Fair Average Poor Bad N/A
Accessibility:
(Contents, Index, Headings, Numbering, Glossary)
Good Fair Average Poor Bad N/A
Your evaluationof thisdocumentation
Intelligibility:
(Language, Vocabulary, Readability & Clarity, Technical Accuracy, Content)
Good Fair Average Poor Bad N/A
Yoursuggestions forimprovement ofthisdocumentation
Please check the suggestions which you feel can improve this documentation:
Improve the overview/introduction Make it more concise/brief
Improve the Contents Add more step-by-step procedures/tutorials
Improve the organization Add more troubleshooting information
Include more figures Make it less technical
Add more examples Add more/better quick reference aids
Add more detail Improve the index
Other suggestions
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
# Please feel free to write any comments on an attached sheet.
If you wish to be contacted regarding your comments, please complete the following:
Name Company
Postcode Address
Telephone E-mail
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
4/37
This page is intentionally blank.
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
5/37
Contents
About this Manual............................................................. i
Purpose................................................................................ i
Intended Audience ................................................................. i
Prerequisite Skill and Knowledge.............................................. i
What is in This Manual............................................................ i
Related Documentation.......................................................... ii
Conventions......................................................................... ii
How to Get in Touch............................................................. iii
Chapter 1..........................................................................1
Chapter Name ..................................................................1
Basic Instruction.............................................................1
Precautions ....................................................................2
Emergency Maintenance Work Flow ...................................2
Chapter 2..........................................................................5
Emergency Maintenance .................................................5
Individual BTS Maintenance..............................................5
Multiple BTSs Maintenance ............................................. 11
Chapter 3........................................................................13
Fault Feedback...............................................................13
Fault Feedback Factors ..................................................13
Feedback Data.............................................................. 15
BTS Dynamic Data Query..................................................... 16
Abis Interface Signaling Trace............................................... 16
OAM Signaling Trace ........................................................... 17
Alarm File Collection............................................................ 17
Foreground Print File collection ............................................. 18
BTS Version Information ...................................................... 19
ZDB File Collection.............................................................. 19
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
6/37
Appendix A.....................................................................21
Abbreviations .................................................................21
Appendix B .....................................................................23
Figures............................................................................23
Appendix C .....................................................................25
Tables.............................................................................25
Appendix D.....................................................................27
Index ..............................................................................27
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
7/37
Confidential and Proprietary Information of ZTE CORPORATION i
About this Manual
Purpose
This Manual provides basic information about ZXG10-BS30 BTS
emergency maintenance.
Intended Audience
This document is intended for Maintenance personnels whoperform maintenance activities on ZXG10-BS30 BTS.
Prerequisite Skill and Knowledge
For effective use of this document, users should have a good
understanding of GSM architecture. Familiarity with the followingis helpful:
ZXG10-BTS family and its various components
ZXG10-BS30 operating procedures
What is in This Manual
This Manual contains the following chapters:
This Manual contains the following chapters:
TA B L E 1 - C H A P T E R SUM M ARY
Chapter Summary
Chapter 1,
Overview
Describes basic instruction, precautions
and workflow of emergencymaintenance.
Chapter 2,
Emergency Maintenance
Describes emergency maintenance forservice interrupted BTS.
Chapter 3,
Fault Feedback
Describes fault feed back factors andfeed data collection methods.
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
8/37
ZXG10-BS30 (V1.5) Compact Outdoor BTS Maintenance Manual (Emergency Handling)
ii Confidential and Proprietary Information of ZTE CORPORATION
Related Documentation
The documentation set also includes the following manuals:
ZXG10-BS30 (v1.5) Compact Outdoor BTS Guide toDocumentation
ZXG10-BS30 (v1.5) Compact Outdoor BTS MaintenanceManual (Routine Maintenance)
ZXG10-BS30 (v1.5) Compact Outdoor BTS MaintenanceManual (Troubleshooting)
ZXG10-BS30 (v1.5) Compact Outdoor BTS Technical Manual
ZXG10-BS30 (v1.5) Compact Outdoor BTS Hardware Manual
ZXG10-BS30 (v1.5) Compact Outdoor BTS Installation
Manual
Conventions
ZTE documents employ the following typographical conventions.
TA B L E 2 T Y P O G R A P H I C A L C O NVENT I O NS
Typeface Meaning
Italics References to other Manuals and documents.
Quotes Links on screens.
Bold Menus, menu options, function names, inputfields, radio button names, check boxes, drop-down lists, dialog box names, window names.
CAPS Keys on the keyboard and buttons on screensand company name.
Const ant wi dth Text that you type, program code, files anddirectory names, and function names.
[ ] Optional parameters.
{ } Mandatory parameters.
| Select one of the parameters that are delimitedby it.
Note: Provides additional information about acertain topic.
Checkpoint: Indicates that a particular step needsto be checked before proceeding further.
Tip: Indicates a suggestion or hint to make thingseasier or more productive for the reader.
TypographicalConventions
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
9/37
About this manual
Confidential and Proprietary Information of ZTE CORPORATION iii
TA B L E 3 MO USE OP E R A T I O N CO NVENT I O NS
Typeface Meaning
Click Refers to clicking the primary mouse button (usuallythe left mouse button) once.
Double-click Refers to quickly clicking the primary mouse button(usually the left mouse button) twice.
Right-click Refers to clicking the secondary mouse button(usually the right mouse button) once.
Drag Refers to pressing and holding a mouse button andmoving the mouse.
How to Get in Touch
The following sections provide information on how to obtainsupport for the documentation and the software.
If you have problems, questions, comments, or suggestionsregarding your product, contact us by e-mail [email protected]. You can also call our customer supportcenter at (86) 755 26771900 and (86) 800-9830-9830.
ZTE welcomes your comments and suggestions on the qualityand usefulness of this document. For further questions,
comments, or suggestions on the documentation, you can
contact us by e-mail at [email protected]; or you can fax yourcomments and suggestions to (86) 755 26772236. You can alsobrowse our website at http://support.zte.com.cn, which containsvarious interesting subjects like documentation, knowledge base,forum and service request.
Mouse
OperationConventions
CustomerSupport
DocumentationSupport
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
10/37
ZXG10-BS30 (V1.5) Compact Outdoor BTS Maintenance Manual (Emergency Handling)
iv Confidential and Proprietary Information of ZTE CORPORATION
This page is intentionally blank.
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
11/37
Confidential and Proprietary Information of ZTE CORPORATION 1
C h a p t e r
1
Chapter Name
This chapter describes basic instructions, precautions and work
flow of emergency maintenance.
Basic InstructionBefore doing emergency maintenance work, consider and followthe basic instructions:
1. Emergency maintenance should focus on restoring the
normal running of the equipment quickly.
2. To be more efficient in emergency troubleshooting, read
emergency maintenance documents in advance.3. In case of service interruption, contact maintenance
personnel at the OMCR side, query the related OMCR alarmsand identify the problem.
If the service interruption occurs to multiple BTSs, check
whether the Abis interface and the transmission circuitare normal.
If the module or board gets faulty, make sure whetherthe data or version of the board is changed.
If BSC, transmission equipment or transmission circuits
are normal, check and maintain the BTSs. Contact maintenance personnel at the OMCR side to co-
operate with the emergency maintenance at BTS side.
Carry the tools and common spare parts to the BTS sitefor emergency maintenance.
4. After finishing the emergent fault processing, collectequipment alarm information related to this accident. Sendthe relevant fault processing report, equipment alarm fileand log file to ZTE for fault analysis and location.
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
12/37
ZXG10-BS30 V1.5Compact Outdoor BTS Maintenance Manual(Emergency Handling)
2 Confidential and Proprietary Information of ZTE CORPORATION
PrecautionsEmergency maintenance usually has an impact on system
running, so the maintenance personnel must have relevantmaintenance experience and familiar with the equipment.
Conduct maintenance under the instruction of experiencedmaintenance personnel.
If the fault is major, contact ZTE customer support center or ZTElocal office as soon as possible.
Emergency Maintenance
Work FlowF I G URE 1 - EM ERG ENCY MA I NT E NA N CE W O R K FL O W
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
13/37
Chapter 1Chapter Name
Confidential and Proprietary Information of ZTE CORPORATION 3
Emergency maintenance flow includes the following steps.
1. Check the services.
According to service interruption, check whether the BTS fails
through the topological view, and check the alarm informationon OMCR client. Also check whether the fault occurs to individual
BTS or multiple BTSs.
2. Record fault abnormality and identify the fault cause.
Identify the fault cause according to the emergencymaintenance process in Figure 1 and make record, as shown inTable 4.
TA B L E 4 - A B N O R M A L I T Y R ECO RDS
Item Description of Abnormality
Emergency case occurring time
Emergency case range
Serious alarm item reported
Measurement index of abnormalperformance
Board with abnormal LEDindicators
BTS Version Number
OMCR version
Operation log information
Status query information
Signaling trace information
3. Detect and analyze the fault.
Detect and analyze the fault according to the fault symptoms.
If the fault is not caused by the BSS equipment, ask the relevantpersonnel to solve the problem.
If the fault lies in the BSS equipment, analyze whether the faultis in BSC or BTS.
If the fault cannot be cleared, then contact ZTE customersupport center or ZTE local office.
4. Restore the service.
After locating the fault cause, restore the service quickly. If thefault cause cannot be located soon, try to make a switchover,reset or change the board to restore the system services.
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
14/37
ZXG10-BS30 V1.5Compact Outdoor BTS Maintenance Manual(Emergency Handling)
4 Confidential and Proprietary Information of ZTE CORPORATION
Notes:
Before restoring the services, back up the system data.
Before changing the hardware configuration, such asconnection and board slot, record the current status first.
Record all steps and process during the service recovery.
5. Observe the restored service
After restoring the service from emergent fault, make sure thesystem runs normally.
Check the service recovery by making call test, and checkperformance report statistics.
6. Feedback
Summarize the fault process, record the fault processing tableand feed back to ZTE customer support centre.
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
15/37
Confidential and Proprietary Information of ZTE CORPORATION 5
C h a p t e r
2
Emergency Maintenance
This chapter describes about emergency maintenance for service
interrupted BTS.
Emergency maintenance applies in the following two cases:
Individual BTS service interruption
Multiple BTS service interruption
Individual BTS MaintenanceFigure 2 shows the emergency maintenance flow chart forservice interrupted individual BTS.
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
16/37
ZXG10-BS30 V1.5Compact Outdoor BTS Maintenance Manual(Emergency Handling)
6 Confidential and Proprietary Information of ZTE CORPORATION
F I G URE 2 I N D I V I D U A L B TS EM ERG ENCY MA I NT E N A NCE FL O W C H A R T
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
17/37
Chapter 2Emergency Maintenance
Confidential and Proprietary Information of ZTE CORPORATION 7
BTS emergency maintenance involves the following steps:
View the alarm information and performance statistics reportat OMCR client. Collect subscribers complaints and analyzethe BTS fault situation.
Check whether the fault caused to individual BTS or multiple
BTSs.
Check the power supply is stable or not. If not, observe it for awhile and then perform the following tests.
Check external power voltage range at the input port of thecabinet.
Normal system voltage range is given below:
Approximate working power supply voltage is 220 VAC
(130 VAC~300 VAC).When 110 VAC power input, the approximate value is110 VAC (88 VAC~ 132 VAC).
If the external power supply is normal, turn off the powersupply switch. Check the connections between power cablesand the cabinet.
If the connections are loose, then check whether the power
supply channel has the burst trail.
Confirm the transmission status with the Maintenance
personnel to make sure whether the transmission status isnormal.
Make sure whether data adjustment or cut-over was madebefore.
Perform the transmission loop test from BTS and BSC to
identify the transmission status.
Uplink and downlink signal communications are normal andthe BTS cannot be normally started when there are cross
connected lines for transmission.
If the problem lies in transmission, ask the transmission
personnel to handle it as soon as possible.BTS has the following requirements for transmission indices:
Transmission Bit Error Ratio (BER) should be lesser than 10-6.
Otherwise, it may lead to data output error or LAPD transientinterruption.
Satellite transmission delay should be lesser than 260 ms.Otherwise, it may cause call drop, congestion or abnormaldata transmission.
Clock precision should be lesser than 0.05 ppm(corresponding to 13 MHz 0.65 Hz). If the switching
Check SystemServices
Power SupplyFailure
Transmission
Failure
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
18/37
ZXG10-BS30 V1.5Compact Outdoor BTS Maintenance Manual(Emergency Handling)
8 Confidential and Proprietary Information of ZTE CORPORATION
requirement is not considered, the clock precision for the
external can be 0.2 ppm.
Normally, BTS clock precision should be less than 0.02 ppm.
TS allocation failure causes LAPD interruption under normaltransmission conditions.
Main causes of TS allocation failure:
Inconsistency between the background configuration dataand the data indicated by the DIP can cause LAPDinterruption.
E1 timeslot multiplexer in the middle of the transmission
path can cause TS allocation inconsistency between BTS andBSC.
When multiplexer fails or its data configuration is wrong. E1timeslot for the BTS cannot transmit data transparently andBTS LAPD functions improperly.
BSC and BTS check the received signals, not transmissionsignal. So, transmission problem will not be reported as analarm. Remove the transmitting E1 on either side and checkwhether the peer side can receive signals.
BSC can detect a remote alarm on the downlink. LEDIndicator on the TIC will not blink when the downlink E1 doesnot receive signals.
Record LED indicator states of the faulty boards, as shown in
Table 6.
TA B L E 5 - FA UL T B O A R D I NDI CAT O R ST A T U S E S
LEDIndicator
Color
(A for Red/Bfor Green)
Blinking Pattern
(1 Hz A/4 Hz B/ConstantlyOn C/ Constantly OffD/Others E)
Others
(In the Case of E)
Record faulty boards location in the following format:
Site type:
Model:
Position:
Record the hardware and software version number, as shownin Table 6.
Hardware
Failure
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
19/37
Chapter 2Emergency Maintenance
Confidential and Proprietary Information of ZTE CORPORATION 9
TA B L E 6 - R ECO RD HA RDWA RE /S O F T WARE VERSI O N NU M B E R
Equipment Module Version
CMM
CMM_LOG
FUC_LOG
CIP
CHP
BS30 (v1.5)
FUC
Power-off the faulty module and then power it on again.
Unplug the module and then plug it again.
Replace the faulty module.
Check the BTS and transmission equipment grounding.
Check whether the grounding cable is loose, aging or rusty.
Check whether the grounding resistance is in the normal
range.
Check whether the grounding drop line is connected to theground grid fixedly.
Check whether the ground grid system complies with the
design, and whether receptivity reduction mixture is addedregularly.
Check the antenna feeder cable connections.
Check whether the impedanceof TIC board is consistent withBTS.
Check whether the radio data and version type are correct.
Check whether the data configured at the switching side arecorrect.
After troubleshooting, fill the maintenance details in the BTSmaintenance table.
F I L L I N T H E B TS M A I N T E N A N C E T A B L E , A S S H O W N I N
Table 7.
Externalproblems
BSC Failure
Feedback
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
20/37
ZXG10-BS30 V1.5Compact Outdoor BTS Maintenance Manual(Emergency Handling)
10 Confidential and Proprietary Information of ZTE CORPORATION
TA B L E 7 - B TS MA I N TE NA NC E R ECO RD
OfficeName
MaintenancePersonnel
Tel
HandlingTime
Model Version
Fault time,abnormityindicationanddescription
OnsiteMaintenance details
Result andConclusion
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
21/37
Chapter 2Emergency Maintenance
Confidential and Proprietary Information of ZTE CORPORATION 11
Multiple BTSs Maintenance
F I G URE 3 - MU L T I P L E B TS EM ERG ENCY MA I NT EN A N CE F L O W CH A R T
Check the working status of current BSS network throughthe background alarm information and confirm the currentnetwork fault.
Check SystemServices
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
22/37
ZXG10-BS30 V1.5Compact Outdoor BTS Maintenance Manual(Emergency Handling)
12 Confidential and Proprietary Information of ZTE CORPORATION
Check the power supply is stable or not. If not, observe it fora while and then perform the following tests.
Check external power voltage range at the input port of thecabinet.
Normal system voltage range is given below:
Approximate working power supply voltage is 220 VAC
(130 VAC~300 VAC).
When 110 VAC power input, the approximate value is110 VAC (88 VAC~ 132 VAC).
If the external power supply is normal, turn off the powersupply switch. Check the connections between power cablesand cabinet.
If the connections are loose, then check whether the powersupply channel has the burst trail.
Confirm the transmission status with the maintenance
personnel to make sure whether the transmission status isnormal.
Make sure whether data adjustment or cut-over was madebefore.
Perform the transmission loop test from BTS and BSC toidentify the transmission status.
If the problem lies in transmission, ask the transmissionpersonnel to handle it as soon as possible.
If the interrupted BTSs are in cascading relation, powersupply failure or transmission interruption of a node BTS may
cause service interruption of other BTSs.
If the TIC or LAPD board is failure, the interruption occurs toBTSs that are on the same board.
Replace TIC or LAPD board in time, observe the channel
working status of BTSs in the dynamic data managementand restore the BTSs.
After troubleshooting, fill the maintenance details in the BTSmaintenance table.
Fill in the BTS maintenance table, as shown in Table 8.
Power SupplyFailure
TransmissionFailure
Link Failure
BSC BoardFailure
Feed back
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
23/37
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
24/37
ZXG10-BS30 V1.5Compact Outdoor BTS Maintenance Manual(Emergency Handling)
14 Confidential and Proprietary Information of ZTE CORPORATION
Troubleshooting Record
Record the server operation procedure by onsite personnel,
for the convenience of query. Record steps and time of onsite troubleshooting
Record troubleshooting operations
System Data Record
The data record has the status and problem information ofsystem running, which is the major way to locate the systemproblem.
Fault Feedback Table
Fault feedback table is shown in Table 8.
TA B L E 8 - O N -S I T E FA UL T FE E D B A C K TA B L E
Feedback byFeedbackTime
Received by
Onsite ContactPerson
TelEmail addressof ContactPerson
Department Model
Network Capacity Version
Fault time,abnormalityindications anddescription
Onsite OperationProcedure andHandling Process
Onsite DataFeedback
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
25/37
Chapter 3Fault Feedback
Confidential and Proprietary Information of ZTE CORPORATION 15
Analysis andPreliminaryProcessingRemarks
Final processingSuggestions andConclusion
Person inCharge
Date
Feedback DataFeedback data about the BTS is listed in Table 9.
TA B L E 9 - F E E D B A C K DA T A O F B T S
Feedback DataRequired
Data Collection Method Usage
Site name, sitenumber, and BTSmodel
To query the proper site in theZDB file with relation to sitename and site number
Dynamic dataobservation
information, includingcell, carrier frequencyand channel
Refer Section Log on to theclient
Channel status is another way tojudge the system status
Abis InterfaceSignaling Trace
Refer Section Log on to theclient
Record the call status
OAM signaling traceRefer Section OAM signalingtrace
Record the information at theBTS
History alarm file andhistory notificationmessage in a week
Refer Section Logon to theclient
Record the fault information
Foreground print fileRefer Section Enter the
command
Foreground print information
records the abnormal situation
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
26/37
ZXG10-BS30 V1.5Compact Outdoor BTS Maintenance Manual(Emergency Handling)
16 Confidential and Proprietary Information of ZTE CORPORATION
Feedback DataRequired
Data Collection Method Usage
occurring in the running BSC
BTS versionRefer Section Logon to theclient
Different versions supportdifferent functions
Foreground ZDB fileRefer Section . Enter thecommand
Record the configurationinformation of foreground andconfirm the configurationinformation
BTS Dynamic Data Query
1. Log on to the client and Click Configuration ManagementDynamic data Managementin the OMCR main interface.
2. Select terrestrial or radio resources on navigation tree on the
left in the main interface. Right side of the main interfaceshows the dynamic properties of the site.
3. Perform dynamic properties and query operation.
4. Select Logical SiteCell nodeon the navigation tree and
select the cell, TRX(carrier frequency) or channelto query.
Note:Dynamic data consists of three status levels: cell-
level status, carrier frequencylevel status and channel-levelstatus. Conduct the query and get the information separately.
Abis Interface Signaling Trace
1. Log on to the client, select Performance Management
Signaling Trace on the OMCR main interface to enter thesignaling trace main interface.
2. Select Signaling TraceStarton the signaling trace main
interface to enter the signaling trace setupwindow.
3. Select BSC to be traced, select Abis interface message andAbis interface setting.
4. Click OK. Abis interface tracing window appears. Thentracing on Abis interface signaling is triggered.
5. Save the signaling to the specific target path and in thespecific filename.
6. To record the signaling trace data, click Record button todisplay Save dialogbox, and select the destination path andfile name to be saved.
Steps
Steps
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
27/37
Chapter 3Fault Feedback
Confidential and Proprietary Information of ZTE CORPORATION 17
7. Abis interface trace has a large influence on the system load,
so each trace cannot be more than 10 minutes.
OAM Signaling Trace1. OAM signaling trace method is same as Abis signaling trace.
2. Only select message type as OAM message and relevantsites.
Refer Section Log on to theclient.
Alarm File Collection
Unrecovered Alarm
1. Logon to the client, select Fault Management Alarm
management,to enter alarm management main interface.
2. Click File History Alarm Query on the alarm
management interface.
3. Select Currently Unrecovered Alarm in the Query Typeoption.
4. Select Start timeand Stop time in the intervaland click
Next.5. Select the relevant network management domain and select
all alarm.
6. Click Nextand select Alarm type in Select box, select Alarm
level in Select Alarm Class box, click ALL to select allalarm levels.
7. Click Finishto output alarm data.
History Alarm
1. Click File History Alarm Query on the alarm
management interface.
2. Select Recovered Alarm in the Query type option. Select
the day in the previous week as the date, including thecurrent day.
3. Select Start timeand Stop time in the intervaland clickNext.
4. Select the relevant network management domain and selectall alarm.
Steps
Steps
Steps
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
28/37
ZXG10-BS30 V1.5Compact Outdoor BTS Maintenance Manual(Emergency Handling)
18 Confidential and Proprietary Information of ZTE CORPORATION
5. Click Nextand select Alarm type in Select box, select Alarm
level in Select Alarm Class box, click ALL to select allalarm levels.
6. Click Finishto output alarm data.
Information Message
1. Select File History Querymenu in alarm management
interface to enter the interface for the conditional alarmquery.
2. Select Informationas the query type and time period to bequeried.
3. Select OMCR Background Notification as the informationsource and then the NM domain to be queried.
4. Select the alarm code to be queried and select All NotificationCodes.
5. Click Finishto finish the operation.
6. Select report output to export the result to an EXCEL file.
Foreground Print File collection
1. Enter the command prompt.
2. Log on to the server.
3. Change to home directory.
Execute the following command:
#cd $OMCHOME
4. Connect to foreground.
Execute the following command:
#Omcf t p
5. Connect the corresponding MP.
For example: Connect x. y. z
Tip:x indicates the ID of the BSC and y for the module No.
The value of z is usually 2 and 3. The value 2 indicates active MPand 3 indicates standby MP.
Execute the following command:
f t p>connect 1. 1. 2
6. Get LOG file from the / TRACEdirectory.
Enter in to the / TRACEdirectory
Execute the following command:
Steps
Steps
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
29/37
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
30/37
ZXG10-BS30 V1.5Compact Outdoor BTS Maintenance Manual(Emergency Handling)
20 Confidential and Proprietary Information of ZTE CORPORATION
6. Connect to the corresponding MP.
For example: Connect x. y. z
Tip:indicates the ID of the BSC and y for the module No.The value of z is usually 2 and 3. The value 2 indicates active MPand 3 indicates standby MP.
Execute the following command:
f t p>connect 1. 1. 2
7. ZDB files are stored in / dat a/ wor kdirectory of MP board.
Execute the following command to change the directory:
cd data/ work/
8. Download ZDB files.
Execute the following command:f t p>prompt
f t p> mget *. *
f t p>bye
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
31/37
Confidential and Proprietary Information of ZTE CORPORATION 21
A p p e n d i x
A
Abbreviations
Abbreviation Full Name
A
AC Alternative Current
ADSL Asymmetrical Digital Subscriber Line
B
BSC Base Station Controller
BSS Base Station System
BTS Base Transceiver Station
C
CHP Channel Processor
CIP Carrier Interface Part
CLK Clock
CMM Control and Maintenance Module
D
DC Direct Current
F
FUC Frame Unit Controller
G
GSM Global System for Mobile communication
H
HDLC High level Data Link Controller
L
LAPD Link Access Protocol D-Channel
M
MP Main Processor
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
32/37
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
33/37
Confidential and Proprietary Information of ZTE CORPORATION 23
A p p e n d i x B
Figures
Figure 1 - Emergency Maintenance Work Flow ........................2
Figure 2 Individual BTS Emergency Maintenance Flow Chart ..6
Figure 3 - Multiple BTS Emergency Maintenance Flow Chart.... 11
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
34/37
ZXG10-BS30 V1.5Compact Outdoor BTS Maintenance Manual(Emergency Handling)
24 Confidential and Proprietary Information of ZTE CORPORATION
This page is intentionally blank.
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
35/37
Confidential and Proprietary Information of ZTE CORPORATION 25
A p p e n d i x
C
Tables
Table 1 - Chapter Summary..................................................i
Table 2 Typographical Conventions ...................................... ii
Table 3 Mouse Operation Conventions ................................. iii
Table 4 - Abnormality Records..............................................3
Table 5 - Fault Board Indicator Statuses ................................8
Table 6 - Record Hardware/Software Version Number..............9
Table 7 - BTS Maintenance Record ......................................10
Table 8 - On-Site Fault Feedback Table................................14
Table 9 - Feedback Data of BTS..........................................15
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
36/37
ZXG10-BS30 V1.5Compact Outdoor BTS Maintenance Manual(Emergency Handling)
26 Confidential and Proprietary Information of ZTE CORPORATION
This page is intentionally blank.
-
8/11/2019 221660734 Compact OutDoor BS30 BTS Maintenance Manual1
37/37
A p p e n d i x
D
Index
Abis Interface Signaling Trace..... ......18
Alarm File Collection.........................19Base Station Dynamic Data................18bit error ratio....................................... ..7
BTS Version Information...................21Clock precision.....................................7Emergency maintenance.................... ...1
Foreground Print File ...................... ...20
History Alarm.....................................19Information Message..........................20OAM Signaling Trace ........................19
transmission delay....................... .........7Unrecovered alarm.......................... ...19ZDB File ...................... ......................21