6C5037c 6C5037c 1 25 - 63 A Residual Current Circuit Breaker (RCCB) 25 - 63 A CERTIFICATE OF TESTS Certified that this Hager RCBB was tested for compliance to all routine tests specified in IS12640 Type 1. Test of Sensitivity OK 2. Tripping Time OK 3. Tripping Current OK 4. Performance of Test Device OK 5. H.V. Test at 2,5 KV OK Warning Is 12640 - Part 1 recommends that RCCB should not be considered as a sole means of protection. It is essential to provide proper earthing. All parts of the system should be properly insulated. RCCB does not eliminate the electric shock but limits duration of passage of current through human body to such a short time, probabilities of a lethal effect are reduced to a minimum. OFF Test Click ! Test : Test regularly : RCCB must trip. Advice: Products should be installed inside suitable IP rated enclosures to prevent dust entering inside the mechanism. RCCBs should be installed in an enclosure with minimum IP5X protection level, when used in excessive dusty environments like construction sites, cement/mineral plants etc, or outdoor applications. RCCBs should be used along with SCPDs like MCBs connected downstream. 14 mm max. 25-63 A 16 mm 2 25 mm 2 or

Upload: others

Post on 20-Feb-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 25 - 63 A Residual Current Circuit Breaker (RCCB) 25 - 63 A 25 - 63A.pdfRCCB 2 & 4 gG Fuse NB, NC, ND MCB 25 A 40 A 63 A 25 A 40 A 63 A 25 A X X 40 A X X 63 A X X or I2t, Ip (IEC 61008-1

échelle 100%

échelle 50%

6C50

37c

6C5037c1

25 - 63 A

Residual Current Circuit Breaker (RCCB) 25 - 63 A

CERTIFICATE OF TESTSCertified that this Hager RCBB was tested forcompliance to all routine tests specified in IS12640

Type 1. Test of Sensitivity OK2. Tripping Time OK3. Tripping Current OK4. Performance of Test Device OK5. H.V. Test at 2,5 KV OK

Warning Is 12640 - Part 1 recommends that RCCB should not be considered as a sole means of protection. It is essential to provide proper earthing. All parts of the system should be properly insulated. RCCB does not eliminate the electric shock but limits duration of passage of current through human body to such a short time, probabilities of a lethal effect are reduced to a minimum.

OFF

AI1_ID_Inde_T1_04

échelle 40%

Test

Click !

Test : Test regularly : RCCB must trip.

Advice:Products should be installed inside suitableIP rated enclosures to prevent dust enteringinside the mechanism.RCCBs should be installed in an enclosurewith minimum IP5X protection level,when used in excessive dusty environmentslike construction sites, cement/mineral plantsetc, or outdoor applications.RCCBs should be used along with SCPDslike MCBs connected downstream.

Advice :Products should be installed insidesuitable IP rated enclosures to prevent dust entering inside the mechanism.For dusty environment, we recommend an enclosure with minimum IP 4x protection level

14 mm max. 25-63 A 100 A

16 mm2 35 mm2

25 mm2 50 mm2

Advice : Products should be installed insidesuitable IP rated enclosures to prevent dust entering inside the mechanism.For dusty environment, we recommend an enclosure with minimum IP5x protection level

14 mm max. 25-63 A

16 mm2

25 mm2

or

Page 2: 25 - 63 A Residual Current Circuit Breaker (RCCB) 25 - 63 A 25 - 63A.pdfRCCB 2 & 4 gG Fuse NB, NC, ND MCB 25 A 40 A 63 A 25 A 40 A 63 A 25 A X X 40 A X X 63 A X X or I2t, Ip (IEC 61008-1

Hager Electro Pvt Ltd, Gat No.185, Global Industrial park, Alandi -Ahmednagar Road, Phulgaon, Pune - 412216.IndiaTel: +91 20 66784500 - Website: www.hager.co.in

OC

OM

134

305

Hag

er 0

2.19

6C50

37c

2

AI1_ID_Inde_T2_04b

RCCB2 & 4 �

gG

Fuse

NB, NC, ND

MCB

40 A 25 A25 A 40 A 63 A63 A

XX25 A

XX40 A

XX63 A

or

I2t, Ip (IEC 61008-1 & IS 12640-Part 1)

Protection against over-currentRCCBs without overload protection have to be properly protected against over-current by using backup fuse or MCBs as per table below:

A warranty period of 24 months is offered on hager products, from date of manufacture, relating to any material of manufacturing defect. If any product is found to be defective it must be returned via the installer and supplier (wholesaler). The warranty is withdrawn if: - after inspection by hager quality control dept the device is found

to have been installed in a manner which is contrary to IEE wiring regulations and accepted practice within the industry at the time of installation.

- The procedure for the return of goods has not been followed. Explanation of defect must be included when returning goods.