  • HAN CHANG TRANS

    2500kVA, 22-11kV

    500kVA, 1000-415V

    Distribution Transformer

    By IECwww.hctr.co.kr

  • PROFILE

    Applicable standardFinal paint color

    Insulating oilRated capacity

    Phase/Rated frequencyRated voltage H.VRated voltage L.V

    Tap voltageTap changing method

    Connection or polarityCooling method

    Efficiency

    IEC 60076MUNSELL # 5Y-7/1Mineral Oil500 kVA (winding temp rise 55C)3P / 50Hz11000V Delta 415V Star3 TAPS (5%)De-energized Tap ChangerYNyn0ONAN99.2%

    Compact Design Nameplate per IEC

    Requirement Standard Accessary

    LengthWidthHeight

    OilTotal

    HAN CHANG TRANSFORMER

    500kVA, 11000 Delta volts 415 Star volts,

    DISTRIBUTION TRANSFORMER

    All rights reserved, HanChang Trans, 2013

    The values contained in this document can be changed without prior notice.Exact values will be supplied upon order confirmation.

    1700 mm1700 mm1650 mm

    630 liter2780 kg

  • PROFILE

    Length

    Hei

    ght

    Wid

    th

    HAN CHANG TRANSFORMER

    OUT LINE

    NO DESCRIPTION NO DESCRIPTION

    1 HV BUSHING 14 FILL VALVE

    2 LV BUSHING 15 DRAIN&SAMPLING VALVE 1

    3 HV AIR TERMINAL CHAMBER 16 BASE WELDED TO TANK

    4 LV AIR TERMINAL CHAMBER 17 LIFT LOOPS

    5 RADIATOR 18 GROUND PAD

    6 MANHOLE 19 LIFTING HOOK

    7 PRESSURE RELIEF DEVICE 20 JACKING PAD

    9 MARSHALLING BOX 21 NAME PLATE

    10 LIQUID LEVEL INDICATOR

    11 LIQUID TEMPERATURE INDICATOR

    13 TAP BOARD IN THE TANK

    All rights reserved, HanChang Trans, 2013

    The values contained in this document can be changed without prior notice.Exact values will be supplied upon order confirmation.

    REFERENCE PHOTOS

    500kVA, 11000 Delta volts 415 Star volts,

    DISTRIBUTION TRANSFORMER

  • PROFILE

    Applicable standardFinal paint color

    Insulating oilRated capacity

    Phase/Rated frequencyRated voltage H.VRated voltage L.V

    Tap voltageTap changing method

    Connection or polarityCooling method

    Efficiency

    IEC 60076MUNSELL # 5Y-7/1Mineral Oil2500 kVA (winding temp rise 55C)3P / 50Hz22000V Delta 11000V Star5 TAPS (2.5%)De-energized Tap ChangerDyn11ONAN99.49%

    Compact Design Nameplate per IEC

    Requirement Standard Accessary

    LengthWidthHeight

    OilTotal

    HAN CHANG TRANSFORMER

    2500kVA, 22000 Delta volts - 11000 Star volts,

    DISTRIBUTION TRANSFORMER

    All rights reserved, HanChang Trans, 2013

    The values contained in this document can be changed without prior notice.Exact values will be supplied upon order confirmation.

    2200 mm2850 mm2100 mm

    2340 liter8410 kg

  • PROFILE

    Length

    Hei

    ght

    HAN CHANG TRANSFORMER

    OUT LINE

    All rights reserved, HanChang Trans, 2013

    The values contained in this document can be changed without prior notice.Exact values will be supplied upon order confirmation.

    REFERENCE PHOTOS

    2500kVA, 22000 Delta volts - 11000 Star volts,

    DISTRIBUTION TRANSFORMER

    Wid

    th

    NO DESCRIPTION NO DESCRIPTION

    1 HV BUSHING 12 WINDING TEMPERATURE INDICATOR

    2 LV BUSHING 13 TAP CHANGER

    3 HV AIR TERMINAL CHAMBER 14 FILL VALVE

    4 LV AIR TERMINAL CHAMBER 15 DRAIN&SAMPLING VALVE 1

    5 RADIATOR 16 BASE WELDED TO TANK

    6 MANHOLE 17 LIFT LOOPS

    7 PRESSURE RELIEF DEVICE 18 GROUND PAD

    8 B.C.T BOX 19 LIFTING HOOK

    9 MARSHALLING BOX 20 JACKING PAD

    10 LIQUID LEVEL INDICATOR 21 NAME PLATE

    11 LIQUID TEMPERATURE INDICATOR

  • QualityISO 9001ISO 14001

    www.hctr.co.kr

    2013 Hanchang Transformer co.,ltd. All rights reserved. The information in this publication is provided without any express or implied representation or warranty in relation to any contract which may be entered into. Hanchang shall not be responsible for any loss or damage of whatsoever nature [including consequential loss or damage] suffered or incurred, directly or indirectly, by the reader or any other person as a result of relying on the information contained in this publication.

    Mr. Michael Jang michael@transformerprice.com

    Mr. Taeyoung Kim taeyoung@hctr.co.kr

    Ms. Monica Lyumonica@hctr.co.kr

    INQUIRY

    mailto:Michael@transformerprice.commailto:hanstar912@gmail.commailto:gdr97504@gmail.commailto:hanstar912@gmail.commailto:hanstar912@gmail.com

View more